• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 446
  • 11
  • 10
  • 10
  • 10
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 463
  • 168
  • 103
  • 96
  • 75
  • 66
  • 61
  • 60
  • 54
  • 53
  • 53
  • 47
  • 46
  • 45
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Resistência à fratura de dentes com preparos cavitários MOD restaurados com resina composta e fibra de vidro

Rodrigues, Fausto Borges January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2 000392253-0.pdf: 813004 bytes, checksum: 92cc239906e68f814913bc5491cecb54 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate in vitro the effect of two types of glass fibers, unidirectional or woven, placed inside of MOD cavity preparations on fracture strength of endodontically treated molars, either restored with composite resin, or not. Ninety sound human third molars were extracted, embedded in acrylic resin blocks and randomly assigned to six groups (n=15). Group 1 G1 (sound teeth), control. Groups G2, G3, G4, G5 e G6 were subjected to the following procedures: G2 – MOD cavity preparation; G3 – MOD and endodontic treatment (ET); G4 –MOD + ET + composite resin restoration (CR); G5 – MOD + ET + unidirectional fiber (UF) + CR; G6 - MOD + ET + woven fiber (WF) + CR. The specimens were stored in physiological serum at 37oC for 24 hours. Later, a compressive force was applied by means of a universal testing machine at 1 mm/min speed, parallel to the long axis of the teeth until the fracture occurred. After mechanical test three types of fractures were classified: 1) pulp chamber floor; 2) cusp; 3) pulp chamber floor and cusp. The means of results (N) followed by the same letter do not represent a statistical difference by ANOVA and Tukey (p<0,05): G1 (4960)a, G2 (1926. 20)b, G3 (612. 84)c, G4(1813. 9)b, G5 (2024)b, G6 (1879)b. In the analysis of qualitative variables of G5 and G6, there was a tendency to fracture in the pulp chamber floor and cusp not benefic to restore the tooth integrity. It is possible conclude that inserting the unidirectional or woven glass fibers into MOD cavity preparations and restored with composite resin the fracture strength is similar to that obtained in molars filled with composite resin only. / A proposta deste estudo foi avaliar o efeito de dois tipos de fibras, uma trançada e outra unidirecional, inseridas no interior de cavidades MOD padronizadas na resistência à fratura de dentes molares tratados endodonticamente. Noventa dentes terceiros molares hígidos foram selecionados e montados em blocos acrílicos, sendo estes divididos em seis grupos de quinze (n=15). No grupo G1, os dentes mantiveram-se hígidos (controle). Os grupos G2, G3, G4, G5 e G6 receberam preparos cavitários MOD padronizados, sendo que nos grupos G3, G4, G5 e G6 foram realizados tratamentos endodônticos. Após o preparo dos dentes, estes foram restaurados com resina composta, no grupo G4, e no grupo G5 e G6 foram inseridas dois tipos de fibras, uma trançada e outra unidirecional, respectivamente. Após, os corpos de prova foram submetidos ao ensaio de resistência à fratura. Avaliou-se, também, qualitativamente as falhas classificando-as em fratura de cúspide, assoalho e cúspide mais assoalho, após o ensaio mecânico. Os resultados (N) obtidos foram (médias seguidas de mesma letra não apresentam diferença estatística para Anova e Tukey (p<0,05): Grupo G1 (4960)a, Grupo G2 (1926,20)b, Grupo G3 (612,84)c, Grupo G4 (1813,9)b, Grupo G5 (2024)b, Grupo G6 (1879)b. Conclui-se que a utilização de fibras trançadas ou unidirecionais no interior de cavidades MOD de dentes com tratamento endodôntico não melhora a resistência a compressão apresentando um padrão de fratura de assoalho mais cúspide não favorável à recuperação da peça dentária.
372

Aloenxertos ósseos e enxerto sintético de hidroxiapatita em falha óssea ulnar em galinhas (Gallus gallus domesticus)

Schmitt, Bernardo January 2018 (has links)
A utilização de enxertos ósseos vem aumentando bastante em pequenos animais, entretanto, em aves esta utilização é menor devido à dificuldade de conseguir autoenxerto em quantidades adequadas. Sendo assim, o objetivo do projeto foi avaliar três tipos de enxertos em aves. Foram utilizadas 30 galinhas separadas em três grupos: grupo aloenxerto congelado em ultrafreezer (GUF) por duas semanas; grupo aloenxerto congelado em nitrogênio líquido (GNL) e grupo enxerto sintético de hidroxiapatita deficiente em cálcio (GHA). Os enxertos foram aplicados em defeito ósseo de aproximadamente 20mm na ulna das aves e fixados ao leito receptor com uma placa e quatro parafusos bloqueados. Os animais foram acompanhados por meio de avaliação clínica, radiográfica, histológica e biomecânica. A consolidação radiográfica ocorreu em 90% nos animais do GNL, 70% nos do GUF e 60% nos do GHA, com média de 47,14±13,50 dias no GUF, 61,67±21,79 dias no GNL e aos 70±18,17 dias no GHA, havendo diferença significativa entre o GUF e GHA. Histologicamente os enxertos do GUF apresentavam-se em processo de consolidação mais avançada, com remodelação óssea e a presença de osteoclastos. Na avaliação clínica todas as ulnas operadas tinham estabilidade, sem sinal de inflamação/contaminação, articulações preservadas, sem dor e sem desvios angulares graves na asa. Na análise biomecânica houve diferença significativa (p<0,05) entre o GNL e o GHA na resistência, já na avaliação de flexão máxima, observou-se diferença estatística entre o GHA e o GNL e entre o GHA e o GUF. Sendo assim, é possível concluir que os três enxertos testados podem ser utilizados em defeitos ósseos em aves, mas o melhor deles foi o GNL por apresentar mais vantagens na preparação, confecção, aplicação dos enxertos e resistência biomecânica, com maior taxa de consolidação óssea. / The use of bone grafts is increasing considerably in small animals, however, in poultry this use is less due to the difficulty of obtaining autograft in adequate quantities. Therefore, the objective of the project was to test three types of grafts, evaluating their best results over a period of 90 days. For this purpose, 30 chickens were divided into three groups: frozen ultra freezer allograft group (UFG) for two weeks; allograft frozen in liquid nitrogen group (LNG) and synthetic grafts of calcium deficient hydroxyapatite group (HAG). Grafts were applied to a bone defect of approximately 20 mm in the ulna of birds, in all three groups the grafts were fixed to the recipient bed with plates blocked and 4 screws locked. The animals were followed up by serial radiographs, histological examination, clinical orthopedic evaluation and biomechanical flexion assay. Radiographic consolidation occurred in 90% of the LNG, 70% in the GUF and 60% in the GHA, mean of 47.14 ± 13.50 days without UFG, 61.67 ± 21.79 days non LNG and at 70 ± 18.17 days without HAG, with a significant difference between UFG and HAG. Histologically, UFG grafts were in a more advanced consolidation process, presenting bone remodeling with a presence of osteoclasts In the clinical review, all of them were operated with stability, with no sign of inflammation / contamination, preserved joints, no pain and no angular deviations, graves in the nail. In the biomechanics, there was a significant difference (p <0.05) between LNG and HAG in the resistance, already in the evaluation of maximum flexion, it was observed statistical difference not HAG with LNG and HAG with UFG grafts. Thus, it is possible to conclude that the three grafts tested are feasible to be used in bone loss in birds, where the LNG was superior because it presented more advantages in the preparation, preparation and application of the grafts, presenting a higher rate of bone consolidation.
373

Fixador esquelético externo híbrido em fraturas metafisárias de rádio e tíbia em cães

Reis, Kauê Danilo Helene Lemos dos January 2015 (has links)
As fraturas de ossos longos são frequentes na rotina de pequenos animais, geralmente decorrentes de injúrias de alto impacto, como quedas, acidentes automobilísticos e projéteis. Os fixadores esqueléticos externos são versáteis, podendo ser utilizados em diferentes montagens, como linear, circular, híbrida, unilateral, bilateral, uniplanar, multiplanar, sendo amplamente utilizado em fraturas de rádio e tíbia. O presente trabalho avaliou a utilização de fixador esquelético externo híbrido (FEEH) em fraturas metafisárias de rádio e tíbia em cães atendidos na rotina do Hospital de Clínicas Veterinárias da Universidade Federal do Rio Grande Sul (HCV-UFRGS). Foram incluídos 13 animais neste estudo, cinco com fratura de tíbia e oito com fratura de rádio. Os FEEH, com anel inteiro ou semianel e uma barra, foram pré-montados de acordo com tamanho do animal e localização da fratura. Após redução, aberta ou fechada, foram inseridos os fios de Kirschner no fragmento curto, de maneira divergente, presos ao anel e três pinos de Shanz no fragmento longo fixados à barra por presilhas. Não houve intercorrências transoperatórias. Todos os casos atingiram a consolidação óssea. Os FEEH foram retirados entre cinco e 10 semanas de pós-operatório. As complicações encontradas foram tratos de drenagem (5), complicação resolvida reduzindo intervalo entre curativos, de semanal para diário, desvio angular (4), sendo dois com desvio valgo, um recurvatum e um tanto valgo quanto recurvatum quebra de fio (2), reação periosteal (2). Todos os animais apresentaram uso funcional do membro ao final do período de avaliação. O FEEH foi efetivo para o tratamento de fraturas metafisárias de rádio e tíbia na amostra estudada. / The presence of long bones fractured is often in pets’ routine, these fractures usually happen due to high impact injuries, as falling, automobile accidents and projectiles. The external skeletal fixators are versatile, then they can be used in different assemblies as linear, circle, hybrid, unilateral, bilateral, uniplanar and multiplanar, having wide requisition to radius and tibia. This paper evaluates the uses of hybrid external skeletal fixator (HESF) on metaphyseal fractures of radius and tibia in dogs that were rescued at Hospital of Veterinary Clinics at Federal University of Rio Grande do Sul (HCV-UFRGS). Thirteen dogs were evaluated: five presenting tibial fractures and eight showing radius fractures. The HESF, with full ring or semiring and a sidebar, were pre-assembled in accordance with animal size and fracture site. After reduction, open or closed, the Kirschner wire were inserted in the short fragment, divergently, fixed to the ring and three Schanz pins in large fragment, fixed to the bar. There were not intraoperative complications. All cases reached the bone healing. The HESF were taken off between five and ten weeks postoperative. The noted complications were: drainage tract (4), complication resolved reducing interval between dressings, weekly to daily, angular detour (4), two valgus, one recurvatum and one valgus and recurvatum, wire breaking (2) and periosteal reaction. At the end of evaluation period, all animals presented functional use of the member. In this studied sample, HESF was effective on treatment of metaphyseal fractures of radius and tibia.
374

Necessidade de reabordagem cirúrgica após tratamento de fraturas mandibulares por fixação interna rígida / Necessity of surgical retreatment in mandibular fractures after treatment by rigid internal fixation

Marcos Kazuo Yamamoto 10 August 2010 (has links)
As fraturas de mandíbula são freqüentes e o seu tratamento é por meio de fixação interna rígida. Complicações podem ocorrer após o tratamento das fraturas mandibulares levando a necessidade de reabordagem cirúrgica, havendo poucos estudos a esse respeito na literatura. A proposta deste estudo retrospectivo foi avaliar as características, os possíveis fatores de risco e os tipos de tratamento realizado em pacientes que necessitaram de reabordagem cirúrgica de fraturas de mandíbula tratadas com fixação interna rígida (FIR). Dentre 364 pacientes tratados por fraturas de mandíbula com FIR, houve 17 pacientes (4,7%) que necessitaram de reabordagem cirúrgica, tendo sido incluídos três pacientes provenientes de outros serviços, totalizando 20 casos com necessidade de nova cirurgia. Houve predomínio do gênero masculino, com idade média de 31,4 anos, sendo freqüentes o tabagismo e o etilismo. Foram freqüentes fraturas múltiplas e cominutivas nas regiões de corpo e ângulo mandibular, dente no traço e exposição intraoral da fratura. O tempo de espera para primeira cirurgia foi alto e o acesso extraoral e o sistema de fixação menos rígido 2.0 mm foram freqüentes. As complicações mais comuns foram dor, infecção e mobilidade anormal. Nas culturas bacterianas houve predomínio do Staphylococcus aureus e a imagem mais freqüente foi de reabsorção óssea difusa, seguida por parafuso solto, seqüestro ósseo, traço de fratura visível, fixação solta e placa fraturada. A reabordagem cirúrgica ocorreu em média de 7,5 meses após a primeira cirurgia e constou de remoção dos meios de fixação associada ou não a nova fixação ou ainda a remoção de seqüestro ósseo, sendo que apenas um caso necessitou de refratura. Histologicamente houve predomínio de osteomielite crônica. Os diagnósticos em ordem decrescente foram infecção, pseudoartrose, osteomielite e placa exposta, sendo que muitos pacientes tiveram mais de um diagnóstico. Foi destacada a freqüência de tabagismo e etilismo, fraturas múltiplas e cominutivas na região de corpo e ângulo mandibular, dente no traço, exposição intraoral, tempo de espera alto e acesso extraoral predispondo complicações das fraturas mandibulares e exames de imagem de reabsorção óssea, fixação e parafusos solto e seqüestro ósseo e diagnóstico histológico de osteomielite como característica dos casos requerendo nova cirurgia. / Mandibular fractures are frequent and their treatment is through rigid internal fixation (RIF). Complications can occur after treatment of the mandibular fractures which may require a new surgical procedure, and there are a few studies about that in the literature. The purpose of this retrospective study was to evaluate the characteristics, possible risk factors, and the kinds of treatment did in patients which needed another surgery after treatment of mandibular fracture with RIF. From 364 patients with mandibular fractures treated by RIF, there were 17 patients (4.7%) with need of a new surgery, and 3 patients coming from another city were included, comprising a total of 20 patients who needed a new surgery. There was predominance of the male gender, with a mean age of 31.4 years, being frequent smoking and alcohol abuse. Multiple and comminuted fractures on the body and angle sites, teeth in the fracture line, and intraorally exposed fractures were frequent. Delay time to the first surgery was high, and extraoral approaches and system 2.0mm were predominant. The most common complications were pain, infection and abnormal mobility. In the bacterial culture there was predominance of Staphylococcus aureus, and the most frequent radiographic images were of diffuse bone resorption, loosening of screws, bone sequestration, fracture line visible, loose fixation, and fractured plate. A new surgery occurred with a mean of 7.5 months after the first intervention and comprised plate and screws removal associated or not to a new fixation or bone sequestra removal, and only a case the fracture needed to be osteotomized. Histologically there was predominance of chronic osteomyelitis. The diagnoses in decreasing order were infection, nonunion, osteomyelitis and exposed plate, although many patients had more than one diagnosis. It was evidenced the frequency of smoking and alcohol abuse, multiple and comminuted fracture on the body and angle regions, teeth in the fracture line, intraoral fracture exposition, high delay time and extraoral approaches predisposing complications of the mandibular fractures, and images showing bony resorption, loose hardware and bone sequestra, as well as histological diagnosis of osteomyelitis as characteristic of the cases requiring a new surgery.
375

Fixador esquelético externo híbrido em fraturas metafisárias de rádio e tíbia em cães

Reis, Kauê Danilo Helene Lemos dos January 2015 (has links)
As fraturas de ossos longos são frequentes na rotina de pequenos animais, geralmente decorrentes de injúrias de alto impacto, como quedas, acidentes automobilísticos e projéteis. Os fixadores esqueléticos externos são versáteis, podendo ser utilizados em diferentes montagens, como linear, circular, híbrida, unilateral, bilateral, uniplanar, multiplanar, sendo amplamente utilizado em fraturas de rádio e tíbia. O presente trabalho avaliou a utilização de fixador esquelético externo híbrido (FEEH) em fraturas metafisárias de rádio e tíbia em cães atendidos na rotina do Hospital de Clínicas Veterinárias da Universidade Federal do Rio Grande Sul (HCV-UFRGS). Foram incluídos 13 animais neste estudo, cinco com fratura de tíbia e oito com fratura de rádio. Os FEEH, com anel inteiro ou semianel e uma barra, foram pré-montados de acordo com tamanho do animal e localização da fratura. Após redução, aberta ou fechada, foram inseridos os fios de Kirschner no fragmento curto, de maneira divergente, presos ao anel e três pinos de Shanz no fragmento longo fixados à barra por presilhas. Não houve intercorrências transoperatórias. Todos os casos atingiram a consolidação óssea. Os FEEH foram retirados entre cinco e 10 semanas de pós-operatório. As complicações encontradas foram tratos de drenagem (5), complicação resolvida reduzindo intervalo entre curativos, de semanal para diário, desvio angular (4), sendo dois com desvio valgo, um recurvatum e um tanto valgo quanto recurvatum quebra de fio (2), reação periosteal (2). Todos os animais apresentaram uso funcional do membro ao final do período de avaliação. O FEEH foi efetivo para o tratamento de fraturas metafisárias de rádio e tíbia na amostra estudada. / The presence of long bones fractured is often in pets’ routine, these fractures usually happen due to high impact injuries, as falling, automobile accidents and projectiles. The external skeletal fixators are versatile, then they can be used in different assemblies as linear, circle, hybrid, unilateral, bilateral, uniplanar and multiplanar, having wide requisition to radius and tibia. This paper evaluates the uses of hybrid external skeletal fixator (HESF) on metaphyseal fractures of radius and tibia in dogs that were rescued at Hospital of Veterinary Clinics at Federal University of Rio Grande do Sul (HCV-UFRGS). Thirteen dogs were evaluated: five presenting tibial fractures and eight showing radius fractures. The HESF, with full ring or semiring and a sidebar, were pre-assembled in accordance with animal size and fracture site. After reduction, open or closed, the Kirschner wire were inserted in the short fragment, divergently, fixed to the ring and three Schanz pins in large fragment, fixed to the bar. There were not intraoperative complications. All cases reached the bone healing. The HESF were taken off between five and ten weeks postoperative. The noted complications were: drainage tract (4), complication resolved reducing interval between dressings, weekly to daily, angular detour (4), two valgus, one recurvatum and one valgus and recurvatum, wire breaking (2) and periosteal reaction. At the end of evaluation period, all animals presented functional use of the member. In this studied sample, HESF was effective on treatment of metaphyseal fractures of radius and tibia.
376

Osteossíntese minimamente invasiva com placa (MIPO) sem radiografias transoperatórias no tratamento de fraturas em ossos longos de cães e gatos

Flôres, Lenise Nascimento January 2013 (has links)
As fraturas de ossos longos são frequentes na rotina clínica cirúrgica de pequenos animais. Com o avanço da ortopedia veterinária faz-se necessário aperfeiçoar as técnicas existentes e descobrir novas formas de tratamento menos agressivas e com menos taxas de complicações, como a osteossíntese minimamente invasiva com placas (MIPO). Esta técnica promove a estabilização de fraturas mediante a inserção da placa por pequenas incisões de pele, através de um túnel epiperiosteal, sem mexer no foco de fratura. O objetivo do presente estudo foi avaliar a técnica de MIPO sem radiografia transoperatória no tratamento de fraturas diafisárias em ossos longos de cães e gatos. Para tal foi utilizada uma amostra por conveniência a partir da rotina do Hospital de Clínicas Veterinárias da UFRGS. Participaram efetivamente 15 animais neste projeto, sendo quatro gatos e 11 cães, tendo sido reparadas 16 fraturas. Os animais apresentavam em média 13 ± 9,76 kg(de 3kg a 36,7kg) de peso e 35 ± 26,53 meses (de 6 meses a 7 anos) de idade. Após anestesia geral inalatória e preparação asséptica do membro fraturado, foram realizadas duas pequenas incisões na pele, uma na região proximal e outra na distal do osso fraturado. Após a manipulação e redução fechada da fratura, inseria-se a placa ortopédica metálica pela incisão distal através de um túnel epiperiosteal previamente realizado adjacente ao eixo axial do osso fraturado. A placa foi fixada definitivamente com dois ou três parafusos corticais em cada seguimento, distal e proximal. Os pacientes foram avaliados clínica e radiograficamente a cada 30 dias, até os 90 dias de pós-operatório. Das 16 fraturas corrigidas, oito foram de tíbia, cinco de fêmur e três de rádio. Destas, 10 eram cominutivas, cinco transversas e uma oblíqua. O tempo cirúrgico variou de 31 a 120 minutos (média e desvio padrão de 62,75 ± 22,44 min) independente do osso acometido. A consolidação óssea se deu entre 30 e 120 dias para todos os pacientes, em média aos 73 dias. A complicação mais frequente foi desvio de membro, seguida de reabsorção óssea próxima aos parafusos. Concluiu-se que a técnica de MIPO sem radiografias transoperatórias é eficaz no tratamento de fraturas diafisárias de ossos longos como rádio, tíbia e fêmur de cães e gatos, com uso funcional do membro de forma precoce. / Long bone fractures are a commom event in the small animal practice. As veterinary orthopedics evolves it is necessary to refine existing osteossynthesis methods and develop less invasive methods with lower complication rate. The minimal invasive plate osteossynthesis (MIPO) is a current method develop according to this concept. This technique allows fracture stabilization through small skin incisions and a communicating epiperiosteal tunnel. In addition it does not touch fracture hematoma. The study purpose was to evaluate the MIPO technique to treat small animals long bone fractures without intraoperative radiographs. A convenience sample of clinical patients from the Hospital de Clínicas Veterinárias of UFRGS was used. 15 animals and 26 fractures meet the criteria for the study, four cats and 11 dogs. The animals average weight and standard deviation was 13 kg ± 9,76 (minimum 3kg, maximum 36,7kg) and average age and standard deviation was 35 ± 26,53 months (minimum 6 months, maximum 7 years). After general inhalatory anesthesia, the fracture limb was prepared aseptically. The plate was placed through two small skin incisions one in the proximal aspect of the fractured bone and another distal. After manipulation and closed reduction of the fracture, the plate was inserted through the distal skin incision into the epiperiosteal tunnel previously done. Each bone fragment was attached to the plate with two or three cortical screws. The patients received clinical and radiograph rechecks every 30 days up to 90 days of post-operatory.16 fractures were fixed: eight tibial fractures, five femoral fractures and three radial fractures. 10 were comminuted fractures, five transverse and one oblique. Surgical time was from 31 to 120 minutes, mean 62,75 ± 22,44 minutes. All patients achieved bone healing. Bone healing happened between 30 and 120 days, on average 73 days. The most common complication was limb mal alignment and proximal bone resorption near the implants. MIPO technique was efficient to treat long bone small animal fracture in radius, tibia and femur, allowing earlier functional use of the limb.
377

Simulação do escoamento bifásico de água e óleo em reservatórios de petróleo naturalmente fraturados utilizando métodos de volumes finitos acoplados a modelos de fraturas com dimensão reduzida

BRUM, Braian Schneider 31 January 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-07-23T21:05:22Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Braian Schneider Brum.pdf: 15683511 bytes, checksum: 80e1652e52ac088c04dacdef6294de42 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-07-24T18:17:55Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Braian Schneider Brum.pdf: 15683511 bytes, checksum: 80e1652e52ac088c04dacdef6294de42 (MD5) / Made available in DSpace on 2018-07-24T18:17:55Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Braian Schneider Brum.pdf: 15683511 bytes, checksum: 80e1652e52ac088c04dacdef6294de42 (MD5) Previous issue date: 2017-01-31 / CNPQ / O problema do escoamento bifásico de água e óleo em reservatórios de petróleo heterogêneos e anisotrópicos pode ser descrito utilizando certas hipóteses simplificadoras, por um sistema de equações diferenciais parciais não-lineares, composto por uma equação elíptica da pressão e uma equação hiperbólica de saturação. A modelagem deste problema representa um grande desafio, devido à complexidade dos ambientes deposicionais, incluindo camadas inclinadas, canais, fraturas e a possível existência de poços direcionais. Nesses casos, é particularmente complexo construir malhas estruturadas capazes de modelar o problema físico adequadamente. Esta dissertação tem como objetivo a modelagem numérica do escoamento bifásico em reser-vatórios naturalmente fraturados (RNF). Para isso, são apresentadas duas formulações pelo Método de Volumes Finitos (MVF) centrado na célula para a solução da equação de pressão: a primeira utiliza uma Aproximação de Fluxo por Dois Pontos (TPFA) em conjunto com multi-plicadores de transmissibilidade, e a segunda, capaz de lidar com tensores de permeabilidade completos e malhas poligonais, utiliza uma Aproximação do Fluxo por Múltiplos Pontos (MPFA-O) acoplada ao Modelo de Fraturas com Dimensão Reduzida (Lower-Dimensional Fracture Model - LDFM). O problema hiperbólico da saturação é resolvido pelo método de ponderação a montante de primeira ordem (First Order Upwind Method - FOUM) com duas formulações, uma explícita e outra implícita. A abordagem LDFM é eficiente quando compa-rada a outras estratégias apresentadas na literatura, e faz uso de uma equação adicional associ-ada à fratura que é tratada como uma entidade geométrica com dimensão inferior à do problema original, ou seja, para problemas em 3-D uma fratura é representada por superfícies (2-D) e para problemas em 2-D a fratura tem apenas uma dimensão no espaço. Isso reduz considera-velmente o número de graus de liberdade do sistema. Para isso, a malha deve ser ajustada à distribuição das fraturas no domínio computacional, de modo que essas fraturas são associadas às superfícies de controle, representadas pelas arestas dos volumes finitos em 2-D. É importante observar, que o campo de velocidades nas superfícies de controle que coincidem com as fraturas é dependente, tanto das pressões nas fraturas, quando das pressões nos volumes de controle que representam a rocha matriz e que compartilham os mesmos vértices da respectiva superfície de controle. A acurácia da formulação proposta foi verificada através da resolução de alguns pro-blemas envolvendo meio fraturado, incluindo barreiras e canais. / The problem of two phase flow of oil and water in heterogeneous and anisotropic oil reservoirs can be described using certain simplifying hypotheses by a system of nonlinear partial differential equations, composed by an elliptic equation of pressure and a hyperbolic equation of saturation. The modeling of this problem represents a major challenge due to the complexity of the depositional environments, including inclined layers, channels, fractures and the possible existence of directional wells. In such cases, it is particularly complex to construct structured meshes capable of properly modeling the physical problem. This dissertation aims to model one of these complex structures, naturally fractured reservoirs (NFR). For this, are presented two formulations with Finite Volume Method (FVM), cell-centered, for the solution of the pressure equation: the first one using a Two-Point Flux Aproximation (TPFA) in conjunction with transmissibility multipliers; and the second formulation using the Multi-Point Flux Aproximation (MPFA-O), which can deal with full permeability tensors and arbitrary polygonal meshes, coupled with a Lower-Dimensional Fracture Model (LDFM). The hyperbolic problem of saturation is solved with First Order Upwind Method (FOUM) with two formulations, one explicit and another implicit. The LDFM approach is effective when compared to other strategies in the literature, and makes use of an additional equation associated to the fracture, that is treated as a geometric entity with a smaller dimension than the original problem, in other words, for 3-D problems a fracture is represented by surfaces (2-D) and for 2-D problems the fracture has only one dimension in space. This considerably reduces the number of degrees of freedom of the system. For this, the mesh must be adjusted to the distribution of fractures in the computational domain, when these fractures are associated to the control surfaces, represented by the edges of the finite volumes in 2-D. It is important to note that the velocity field on the control surfaces that coincide with the fractures is dependent, both pressures in the fractures and in the control volumes, which represent the matrix rock and which share the same vertices of the respective control surface. The accuracy of the proposed formulation was verified by solving some problems involving a fractured matrix, including barriers and channels.
378

Colagem de fragmentos em dentes anteriores fraturados : efeito de materiais e tecnicas na resistencia ao impacto / Reattachment of fragments in fractured anterior teeth : effect of materials and techniques on impact strength

Alonso, Renata Camila Bruschi 14 February 2007 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T10:12:27Z (GMT). No. of bitstreams: 1 Alonso_RenataCamilaBruschi_M.pdf: 1462277 bytes, checksum: 2005c106fdedd696c9baa0d0a44fc8ca (MD5) Previous issue date: 2007 / Resumo: O objetivo desse estudo foi avaliar in vitro o efeito de diferentes materiais e técnicas de colagem de fragmentos na resistência ao impacto de dentes anteriores, comparando-a com a resistência à fratura dos dentes hígidos. Para isso, foram selecionados 90 incisivos inferiores bovinos recém-extraídos, com dimensões da coroa de aproximadamente 15 mm de largura mésio-distal e 25 mm de comprimento inciso-cervical. Para a obtenção de fragmentos padronizados, foi realizada secção da coroa de 80 dentes a 12 mm da borda incisal com o uso de disco diamantado em cortadeira Isomet 1000. Remanescentes dentais e fragmentos foram submetidos ao ultrassom em banho de água por 2 horas para remoção da smear layer. Em seguida, os dentes foram embutidos em tubos de PVC com resina acrílica, e o ligamento periodontal foi simulado com poliéter (Impregum Soft). Os dentes seccionados foram distribuídos em 8 grupos (n=10), segundo os materiais e a técnica de colagem de fragmento: G1 - Colagem Direta (CD) + Single Bond (SB) + Filtek Z350 Flow (FF); G2 - CD + Clearfil SE Bond (CSE) + FF; G3 - CD + SB + Rely X CRA (RX); G4 - CD + CSE + RX; G5 - Chanfro Circunferencial (CC) + SB + FF; G6 - CC + CSE + FF; G7 - CC + SB + RX; G8 -CC + CSE + RX. O chanfro circunferencial foi confeccionado após o reposicionamento do fragmento utilizando ponta diamantada esférica (#1016) e, em seguida, restaurado com compósito Filtek Z250 (A3). Todos os materiais foram aplicados de acordo com as instruções dos fabricantes. Dez dentes foram mantidos hígidos para compor o grupo controle. Em seguida, as amostras foram armazenadas em água deionizada a 37oC, durante 24h e submetidas a acabamento e polimento utilizando pontas diamantadas (#3195 F/FF) e sistema Sof-Lex. Para análise da resistência ao impacto, as amostras foram posicionadas em uma máquina universal de testes mecânicos (Instron) de modo que uma carga compressiva foi aplicada na face vestibular a 2 mm do bordo incisal com velocidade de 500 mm/min até a fratura da amostra. Os dados obtidos foram submetidos à Análise de Variância e as médias comparadas pelo teste de Ryan-Einot-Gabriel-Welsch a 5% de significância. Os resultados obtidos, em Kgf, foram, em ordem decrescente: G controle - 64,8; G7 - 43,36; G5 - 37,82; G6 - 37,44; G8 - 26,68; G1 - 26,48; G3 - 23,59; G4 - 17,55; G2 -12,42. A técnica de colagem utilizando Chanfro Circunferencial foi significativamente superior à técnica de Colagem Direta. A utilização do sistema adesivo de condicionamento ácido total Single Bond promoveu aumento significativo na resistência ao impacto quando comparado ao sistema autocondicionante Clearfil SE Bond. Não houve diferença significativa entre os agentes cimentantes Rely X e Filtek Z350 Flow. Nenhuma técnica ou material considerado individualmente foi capaz de devolver ao dente restaurado a resistência mecânica do dente hígido. Somente a associação entre técnica de colagem com Chanfro Circunferencial e sistema de união Single Bond foi capaz de devolver ao dente restaurado a resistência mecânica do dente hígido / Abstract: The objective of this in vitro study was to evaluate the effect of different materials and reattachment techniques on the resistance to impact of anterior teeth and also to compare the resistance to fracture shown by both, sound and restored anterior teeth, considering the different reattachment techniques used. Ninety fresh bovine incisors with crown dimensions of approximately 15 mm of mesiodistal width and 25 mm of incisocervical length were selected. In order to obtain standardized fragments, 80 crowns was sectioned 12 mm from the incisal edge buy means of a diamond saw in an ISOMET 1000 machine. Dental remnants and incisal fragments were submitted to ultrasonic bath for 2 hours, so as to remove smear layer. After the teeth were mounted in PVC rings and embedded in acrylic resin, the periodontal tissue was simulated using polyether (Impregum Soft). The sectioned teeth were distributed in 8 groups (n=10) according to material and reattachment technique: G1 - Direct bonding (DB) + Single Bond (SB) + Filtek Z350 Flow (FF); G2 - DB + Clearfil SE Bond (CSE) + FF; G3 - DB + SB + Rely X CRA (RX); G4 - DB + CSE + RX; G5 - Circumferential Chamfer (CC) + SB + FF; G6 - CC + CSE + FF; G7 - CC + SB + RX; G8 - CC + CSE + RX. The circumferential chamfer was prepared after the bonding of the fragment by means of a spherical diamond point (# 1016). The chamfer was filled with the restorative composite Filtek Z250 (A3). All materials were applied according to the manufacturers' instructions. Ten sound teeth were used as control group. The embedded specimens were stored for 24 hours in deionized water at 37oC and then submitted to finishing and polishing procedures using diamond points (#3195F/FF) and the Sof-Lex system. To evaluate their resistance to impact, the specimens were positioned in a universal testing machine (Instron). A compressive load was applied on the buccal surface, 2 mm from the incisal edge and at a crosshead speed of 500 mm/min, until the failure. The resulting data were submitted to ANOVA One Way and Ryan-Einot-Gabriel-Welsch Multiple Range test at 5% significance. The results (Kgf), were, in decreasing order: G control - 64.8; G7 - 43.36; G5 - 37.82; G6 - 37.44; G8 - 26.68; G1 - 26.48; G3 - 23.59; G4 - 17.55; G2 - 12.42. The fragment reattachment using the circumferential chamfer technique showed results which were significantly better than those shown by direct bonding. In addition, the use of the conventional total-etching bonding system Single Bond caused a significant increase in impact resistance when compared to the use of the self-etching bonding system Clearfil SE Bond. There was no significant difference among the luting agents (Rely X and Filtek Z350 Flow). No technique or material, when individually considered, was capable of achieving the mechanical strength of the sound teeth. Only the association of reattachment technique using circumferential chamfer with the bonding system Single Bond was capable of giving back to the restored teeth the resistance to impact shown by the sound teeth / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
379

Traumatismos faciais em pacientes pediatricos e adolescentes = analise epidemiologica / Maxilofacial trauma in pediatric and adolescent patients : an epidemiological analysis

Muñante Cardenas, Jose Luis 15 August 2018 (has links)
Orientador: Jose Ricardo de Albuquerque Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologika / Made available in DSpace on 2018-08-15T11:26:22Z (GMT). No. of bitstreams: 1 MunanteCardenas_JoseLuis_M.pdf: 1001514 bytes, checksum: 4dea799fe4c80806263615b573dd2c89 (MD5) Previous issue date: 2010 / Resumo: Realizamos um estudo retrospectivo para analisar as diferentes características das fraturas faciais na população pediátrica atendida pela Área de Cirurgia Buco-Maxilo-facial da Faculdade de Odontologia de Piracicaba -UNICAMP entre 1999 e 2008. Foram analisados os prontuários de 2986 pacientes, dos quais 757 foram menores que 18 anos. Os seguintes parâmetros foram avaliados: idade, sexo, etiologia, localização e tipo de fratura, lesões associadas, tratamento e complicações. Resultados: Foram atendidos 530 crianças e adolescentes de gênero masculino (70,01%) e 227 do gênero feminino (29,99%), sendo os adolescentes o grupo etário mais afetado. As causas mais comuns das lesões foram os acidentes de bicicleta (220, 29,06%) e as quedas (215, 28,40%). O osso facial mais afetado por fraturas foi a mandíbula (112, 44,8%) e as lesões associadas mais freqüentes foram as lacerações e o trauma dentoalveolar. O tratamento foi cirúrgico em 75 casos (30%) e as principais complicações foram deiscência, hemorragia pósoperatória e infecção de material de fixação interna. Conclusões: Os acidentes de bicicleta e as quedas foram consideradas as principais causas de injurias maxilo-faciais. A mandíbula foi a mais afetada por fraturas. Estudos epidemiológicos de lesões faciais permitem o desenho das circunstâncias de risco e a identificação dos indivíduos mais sucetiveis. A avaliação da eficácia do tratamento instituído e a compreensão de suas complicações permite uma interpretação realista e coerente da melhor forma como estes doentes devem ser conduzidos. / Abstract: We performed a retrospective study to analyse the different characteristics of such fractures in the pediatric population of Piracicaba Region, Sao Paulo, Brazil. We reviewed the clinical records of 2986 patients. A total of 757 patients under 18 years were treated by the Oral and Maxillofacial Surgery Division of Piracicaba Dental School between 1999 and 2008.The following parameters were evaluated: age, sex, etiology, location and type of fracture, associated injury, treatment and complications. Results: There were 530 boys (70.01%) and 227 girls (29.99%), treated for injuries, with the main prevalence in teenage. The most common injury causes were bicycle accidents (220, 29.06%) followed by falls (215, 28.40%).The facial bone most affected by fractures was the mandible (112, 44.8%) and the associated injuries were lacerations, dentoalveolar trauma and craniofacial trauma. The treatment was surgical in 75 cases (30%) of cases and the main complications were dehiscence, post-operative infection and loosed of internal fixation material and facial paraesthesia. Conclusions: Bicycle accidents and falls were found to be the principal causes of maxillofacial injuries. The facial bone most affected by fractures was the mandible. Epidemiological studies of facial injuries enable the design of the risk circumstances and the identification of the most vulnerable individuals. The evaluation of the effectiveness of treatment instituted and understanding its complications allow a realistic and consistent interpretation about which is the best way for treating these patients. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
380

Efeitos do carbonato de lodenafila na consolidaÃÃo de fraturas da diÃfise femoral de Ratos tratados com haste intramedular / Effects of lodenafil carbonate on femoral diaphysis fractures healing in rats treated with intramedullary stem.

Gisele FaÃanha Diogenes Teixeira 26 February 2010 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / O objetivo do estudo foi verificar os efeitos do carbonato de lodenafil no processo de consolidaÃÃo Ãssea nos fÃmures de ratos reduzidos com fio de Kirshner. Os fatores vasculares sÃo extremamente importantes para a formaÃÃo do calo Ãsseo. O carbonato de lodenafil causa efeitos vasodilatadores, pertence ao grupo dos inibidores da fosfodiesterase seletiva para o tipo 5 (PDE5), enzima que hidrolisa monofosfato de guanosina cÃclico (GMPc). O GMPc induz o relaxamento da musculatura lisa, sendo utilizado no tratamento da disfunÃÃo erÃtil. Foram utilizados 36 ratos machos, adultos, da linhagem Wistar, com o peso mÃdio de 300g. Todos os animais foram submetidos a cirurgia em que era realizada a fratura da diÃfise femoral com uma guilhotina romba. Os animais foram divididos em 2 grupos: o grupo lodenafil, que recebeu, via oral, doses diÃrias de carbonato de lodenafil (10mg/kg) e o grupo controle. Os animais foram sacrificados com 7, 14 e 28 dias de pÃs-operatÃrio. Houve duas mortes, dois falsos trajetos do fio e em trÃs animais nÃo foi estabelecida a fratura. Foram realizados estudo radiogrÃfico com filme de mamÃgrafo para analisar a densidade Ãptica e Ãrea do calo Ãsseo, medida em mm e estudo histolÃgico, utilizando amostras coradas com picrosirius red sob a luz poralizada do microscÃpio, para quantificar a formaÃÃo de colÃgeno tipo I e tipo III na regiÃo cortical prÃxima a fratura e no calo Ãsseo. A densidade de colÃgeno tipo I na regiÃo cortical do fÃmur prÃximo à fratura verificada no grupo lodenafil foi significantemente menor que a observada no grupo controle com 28 dias de consolidaÃÃo Ãssea (**P = 0,0028). Os resultados encontrados nÃo sÃo consistentes o suficiente para afirmar que este fÃrmaco exerce algum efeito na consolidaÃÃo Ãssea. Verificou-se que o Carbonato de lodenafil nÃo influenciou no processo de consolidaÃÃo Ãssea nos fÃmures de ratos reduzidos com fio de Kirshner. / The study was to investigate the effects of Lodenafil Carbonate in the process of bone healing in femurs of rats with reduced KirshnerÂs wire. The vascular factors are extremely important for the formation of callus. Lodenafil Carbonate cause vasodilatory effects, belongs to the group of selective phosphodiesterase type 5(PDE5) inhibitors, that enzyme inhibits cyclic guanosine monophosphate (GMPc) and relaxation of smooth muscles and are used to treat erectile dysfunction. It used 36 male rats, adult male rats, with the average weight of 300g. All animals underwent surgery in which fractures to the femoral shaft with a blunt guillotine. The animals were divided into 2 groups: lodenafil group, wich received oral doses of carbonate lodenafil (10mg/kg) and the control group. The animals were sacrificed at 7, 14 and 28 days postoperatively. There were two deaths, two false paths of the wire and three animals was not established fracture. Were performed radiographic studies with film mammography to analyze the optical density and area of callus, measured in mm  and histological study, using samples stained with picrosirius red under microscope light polarization, to quantify formation of collagen type I and type III in the cortical region near the fracture and callus. The density of type I collagen in the cortical region of the femur near the fracture observed in group lodenafil was significantly lower than that observed in the control group at 28 days of bone (** P = 0.0028). The results are not consistent enough to say that this drug has an effect on bone healing. It was found that the carbonate lodenafil not influence the process of bone healing in femurs of rats with reduced wire Kirshner.

Page generated in 0.0372 seconds