• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 101
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 2
  • 2
  • Tagged with
  • 106
  • 106
  • 33
  • 12
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Aplica??es da teoria da percola??o ? modelagem e simula??o de reservat?rios de petr?leo

Pereira, Marcelo Gomes 06 September 2006 (has links)
Made available in DSpace on 2014-12-17T15:14:45Z (GMT). No. of bitstreams: 1 MarceloGP.pdf: 817916 bytes, checksum: e6c2bd456547cdc5605c7372ebd841db (MD5) Previous issue date: 2006-09-06 / In this thesis we study some problems related to petroleum reservoirs using methods and concepts of Statistical Physics. The thesis could be divided percolation problem in random multifractal support motivated by its potential application in modelling oil reservoirs. We develped an heterogeneous and anisotropic grid that followin two parts. The first one introduce a study of the percolations a random multifractal distribution of its sites. After, we determine the percolation threshold for this grid, the fractal dimension of the percolating cluster and the critical exponents ? and v. In the second part, we propose an alternative systematic of modelling and simulating oil reservoirs. We introduce a statistical model based in a stochastic formulation do Darcy Law. In this model, the distribution of permeabilities is localy equivalent to the basic model of bond percolation / Nesta tese estudamos alguns problemas relacionados a reservat?rios de petr?leo usando m?todos e conceitos da F?sica Estat?stica. A tese pode ser dividida em duas partes. A primeira apresenta um estudo do problema de percola??o em um suporte multifractal aleat?rio motivado por sua potencial aplica??o na modelagem de reservat?rios de petr?leo. Desenvolvemos uma rede heterog?nea e anisotr?pica que segue uma distribui??o multifractal aleat?ria das ?reas de seus s?tios. Em seguida, determinamos o limiar de percola??o nessa rede, a dimens?o fractal do aglomerado percolante e os expoentes cr?ticos ? e v. Na segunda parte, propomos uma sistem?tica alternativa de modelagem e simula??o de reservat?rios de petr?leo. Introduzimos um modelamento estat?stico baseado em uma formula??o estoc?stica da Lei de Darcy. Nele a distribui??o de permeabilidades no reservat?rio equivale localmente ao modelo b?sico de percola??o por liga??es
82

Caracterização de um sistema de fluorescência de raios X por dispersão em energia para análise quantitativa de ligas metálicas / Characterization of a system for X-ray fluorescence energy dispersion for quantitative analysis of metal aeloys

Rafaela Tavares Batista 27 September 2012 (has links)
Neste trabalho são apresentados os procedimentos de caracterização de um sistema comercial portátil de Fluorescência de Raios X por dispersão em energia, o ARTAX 200, bem com seu processo de calibração. O sistema é composto por um tubo de Raios X, com anodo de Molibdênio e um detector XFlash (Silicon Drift Detector) refrigerado por Efeito Peltier. O procedimento de caracterização do sistema foi realizado utilizando-se uma amostra de referência contendo Ferro e Cromo. Foram também usadas amostras certificadas (National Bureau of Standards) D840, D845, D846, D847 e D849 para a realização do processo de calibração do sistema para análise quantitativa. O processo de calibração foi realizado por três metodologias diferentes a fim de avaliar qual deles apresentaria melhores resultados. A caracterização do sistema ARTAX 200 foi realizada executando testes de estabilidade do tubo de Raios X, repetibilidade, reprodutibilidade, resolução em energia do sistema, levantamento da curva de limite de detecção e verificação do centro geométrico do feixe (CG). Os resultados obtidos nos testes de estabilidade apresentaram um coeficiente de variação médio menor do que 2%, o teste de repetibilidade apresentou valores médios menores que 0,5 %. A reprodutibilidade apresentou um coeficiente de variação médio menor que 1,5%. A verificação do centro geométrica mostrou que o CG encontra-se alinhada com o centro ótimo do feixe em duas das três direções do plano cartesiano. A resolução em energia do sistema para a energia de 5,9 keV foi de 150 eV. O limite de detecção apresentou valores menores que 1 % do Si ao Cu. Na avaliação das metodologias para calibração verificou-se que uma das metodologias aplicadas apresentou melhor resultado. Comparando os resultados com outros sistemas portáteis de XRF observa-se que o ARTAX 200 apresenta eficiência superior em relação aos parâmetros analisados. / This paper presents procedures for characterization of a commercial system for portable X-Ray Fluorescence energy dispersive, the ARTAX 200, along with its calibration process. The system consists of an X-ray tube with molybdenum anode and a Silicon Drift Detector XFlash cooled by Peltier effect. The procedure for the characterization of the system was conducted using a reference sample containing Iron Chromium. We also used the certified samples (National Bureau of Standards) D840, D845, D846, D847 and D849 to perform the calibration of the system. The calibration process was conducted by three different methods: Methodology 1, Methodology 2 and Methodology 3, to evaluate them which present better results. The characterization system ARTAX 200 was performed by running stability tests of the X-ray tube, repeatability, reproducibility, resolution in energy of the system, limit of detection and verification of the geometric center of the beam. The results of the stability tests showed an average coefficient of variation of less than 2% repeatability test showed average values lower than 0.5%. The reproducibility showed a coefficient of variation of less than 1.5% which. The verification of the geometric center is aligned with the center of the great beam in two of the three directions of the Cartesian plane. The energy resolution of the system presented to the energy of 5.9 keV a resolution of 150 eV. The detection limit values were less than 1% of the Cu Si. In evaluating methodology for calibrating the best result was obtained with the methodology 3. Comparing the results with other portable XRF systems shows that the ARTAX 200 presents superior efficiency with respect to the parameters analyzed.
83

Aspectos clássicos e quânticos de espinores de dinâmica não-usual : espinores de dimensão de massa um /

Rogério, Rodolfo José Bueno. January 2018 (has links)
Orientador: Julio Marny Hoff da Silva / Banca: Saulo Henrique Pereira / Banca: Marco André Ferreira Dias / Banca: José Abdalla Helayel-Neto / Banca: Alexis Roa Aguirre / Resumo: Na presente tese apresentaremos de forma detalhada o estudo sistemático de uma teoria quântica com férmions de dimensão de massa um que obedecem as estatísticas de Fermi-Dirac, abordando essencialmente sua construção, quantização do campo, análise dos observáveis físicos e aplicações quânticas. Forneceremos todos os detalhes de uma descoberta teórica inesperada da partícula de spin $1/2$ que compõe um conjunto completo de autoespinores com helicidade dual do operador conjugação de carga. Esses espinores recebem o nome de Elko, um acrônimo proveniente do Alemão \textit{Eigenspinoren des Ladungskonjugationsoperators}. Veremos que o elo entre os espaços de representação $(1/2, 0)$ e $(0, 1/2)$ não é dado pela simetria de paridade mas sim pela 'Mágica das matrizes de Pauli', e, portanto, como consequência a dinâmica de tais campos será regida única e exclusivamente pela dinâmica de Klein-Gordon. Tal fato faz com que o propagador associado ao Elko guarde muita similaridade com o propagador do campo escalar. Intrinsicamente, em sua formulação embrionária, as somas de spin para o Elko mostram um termo que quebra explicitamente a covariância relativística, levando então à apreciação da \textit{Very Special Relativity}, que nada mais é do que um subgrupo do grupo de Lorentz, cuja álgebra deixa as somas de spin invariantes ou covariantes. Entretanto, mostraremos que existe uma liberdade na definição da estrutura dual, a qual permite que seja construída uma teoria local e invariante p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present thesis covers in details a systematic study of a quantum theory based on mass dimension one fermions which satisfy the Fermi-Dirac statistics, essentially addressing its construction, field quantization, analysis of physical observables and quantum applications. We provide all the details of an unexpected theoretical discovery of a spin 1/2 particle which composes a complete set of dual helicity spinors of the charge conjugation operator. Such spinors are called Elko, an acronym for the German word Eigenspinoren des Ladungskonjugationsoperators. We show that the relation between the representation spaces (1/2,0) and (0,1/2) is given by the "Magic of Pauli matrices" rather than parity symmetry, therefore, as a consequence the dynamic of such fields is governed solely and exclusively by the Klein-Gordon dynamic. Such fact makes the Elko propagator to be very similar to the scalar field propagator Intrinsically, in its embryonic formulation, Elko spin sums shows up a term that explicitly breaks relativistic covariance, leading to the appreciation of Very Special Relativity, a theory which is based on a subgroup of the Lorentz group, whose algebra leaves the spin sums invariant or covariant. However, we show a freedom in the dual structure definition, which allows the construction of a local and Lorentz invariant theory, thus, leading to a very interesting and promising new physics / Doutor
84

Estudo do alcance de elétrons com energias entre 110 eV e 50 KeV / Range study of electrons with energies between 110 eV and 50keV

Geórgia Santos Joana 29 August 2006 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Existe um grande número de estudos que examina a dependência entre energia e alcance para elétrons com energias desde alguns keVs até centenas de MeVs. Porém, a descrição quantitativa do transporte de elétrons de baixa energia é um problema complexo, especialmente devido à não disponibilidade de dados confiáveis para as seções de choque dos diferentes mecanismos por meio dos quais elétrons interagem com a matéria. Uma vez que os modelos analíticos de transporte de elétrons ou são incompletos ou apresentam dificuldades até o momento intransponíveis, os códigos de Monte Carlo têm sido a alternativa adotada nestas abordagens e são hoje extensivamente utilizados. É sabido que na interação de radiações ionizantes com o tecido vivo podem ocorrer danos severos em estruturas nos níveis celular e sub-celular. Uma vez que a transferência de energia de radiações ionizantes para o meio ocorre predominantemente através da interação dos elétrons secundários produzidos por esta com o material, existe um interesse especial na determinação da relação entre energia inicial e alcance para elétrons; especialmente os de baixa energia. Neste trabalho é estudada a relação entre energia inicial e alcance em meio biológico para elétrons com energias entre 110 eV e 50 keV. Para tal foi utilizado o código de Monte Carlo PENELOPE com o qual foram realizadas simulações do transporte de elétrons de baixa energia (110 eV a 50 keV) e dos fótons secundários gerados por estes provenientes de uma fonte monoenergética isotrópica localizada no interior de um meio tecido equivalente homogêneo. A partir daí, as grandezas de interesse foram calculadas e analisadas.
85

Determinação experimental dos coeficientes de conversão de Kerma no ar para o equivalente de dose pessoal, Hp(d), e fatores de retroespalhamento em feixes de raios-x diagnostico / Measurement of conversion coeficients between air kerma and personal dose equivalent and backscatter factors for diagnostic x-ray beams

Paulo Henrique Gonçalves Rosado 06 March 2008 (has links)
Em proteção radiológica dois conjuntos de grandezas são importantes, as de proteção e as operacionais. Ambas podem ser relacionadas a partir de coeficientes de conversão com grandezas físicas básicas como o kerma. Para feixes de radiação utilizados em radiodiagnóstico nas qualidades da Comissão Internacional de Eletrotécnica (IEC), os coeficientes de conversão e fatores de retroespalhamento ainda não foram determinados. É, portanto, necessário a determinação de coeficientes e fatores para a calibração dos dosímetros que serão utilizados para determinar o equivalente de dose pessoal ou a dose na entrada da pele. Foram determinados experimentalmente os coeficientes de conversão de kerma no ar para o equivalente de dose pessoal, Hp(d), e os fatores de retroespalhamento para as qualidades RQR e RQA da IEC que simulam feixes de raios X diagnósticos. Para a determinação dos coeficientes de conversão é necessário a determinação do kerma no ar dentro do simulador e a energia média do espectro. Foram utilizados dosímetros termoluminescentes do tipo 100H para a medida do kerma no ar no simulador. Os dosímetros foram calibrados utilizando uma câmara de ionização padrão terciário de 180cc da Radcal Corporation. Os dosímetros foram colocados no eixo central de um simulador tipo placa de 300 mm x 300 mm x 15 mm de polimetilmetalacrilato (PMMA) com o intuito de determinar a dose na profundidade. No procedimento de medida os dosímetros foram dispostos em cinco diferentes profundidades (5, 10, 15, 25 e 35 mm). Um outro parâmetro necessário para a determinação dos coeficientes de conversão é a energia média do espectro de raios X. A espectrometria dos feixes de raios X utilizados foi feita utilizando um detector semicondutor de CdTe. O detector foi calibrado utilizando fontes de radiação de 133Ba, 241Am e 57Co. Foram feitas correções em relação a eficiência intrínseca, absorção total de energia, fração de escape de raios X característicos, efeito Compton e atenuação devido a matérias que se encontravam entre o detector e o ponto onde foi determinado a energia média. As medidas do espectro de raios X foram corrigidas utilizado o método de stripping. Os valores das incertezas dos coeficientes de conversão e fatores de retroespalhamento foram da ordem de 12% e 6% respectivamente. / Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. . For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm ×300 mm × 150 mm polymethilmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133Ba, 241Am and 57Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and backscatter factors were 12% and 6% respectively.
86

Desenvolvimento de metodologia para avaliação automatizada da qualidade de imagens digitalizadas em mamografia / Development of methodology for assessment of image quality in mammography digitized

Priscila do Carmo Santana 04 March 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O processo de avaliação da qualidade de imagens radiográficas em geral, e de mamografia em especial, pode ser muito mais preciso, prático e rápido com o auxílio de ferramentas de análise computacional. A proposta deste trabalho é o desenvolvimento de uma metodologia computacional para automatizar o processo de avaliação da qualidade das imagens mamográficas por meio de técnicas de processamento digital de imagens (PDI), utilizando um ambiente de processamento de imagens já existente (ImageJ). Com a aplicação de técnicas de PDI foi possível determinar características geométricas e radiométricas das imagens avaliadas. Os parâmetros avaliados incluem resolução espacial, detalhes de alto contraste, limiar de baixo contraste, detalhes lineares de baixo contraste, massas tumorais, índice de contraste e densidade óptica de fundo. Os resultados obtidos por esta metodologia foram comparados com os resultados apresentados nas avaliações visuais realizadas pela Vigilância Sanitária de Minas Gerais. Por meio desta comparação foi possível demonstrar que esta metodologia automatizada apresenta-se como uma promissora alternativa para redução ou supressão da subjetividade existente na metodologia de avaliação visual, atualmente em uso. / The process of evaluating the quality of radiographic images in general, and mammography in particular, can be much more accurate, practical and fast with the help of computer analysis tools. The purpose of this study is to develop a computational methodology to automate the process of assessing the quality of mammography images through techniques of digital imaging processing (PDI), using an existing image processing environment (ImageJ). With the application of PDI techniques was possible to extract geometric and radiometric characteristics of the images evaluated. The evaluated parameters include spatial resolution, high-contrast detail, low contrast threshold, linear detail of low contrast, tumor masses, contrast ratio and background optical density. The results obtained by this method were compared with the results presented in the visual evaluations performed by the Health Surveillance of Minas Gerais. Through this comparison was possible to demonstrate that the automated methodology is presented as a promising alternative for the reduction or elimination of existing subjectivity in the visual assessment methodology currently in use.
87

Estudo de grandezas dosimétricas aplicadas em pacientes submetidos a exames de tórax rotina em tomografia computadorizada / Study of dosimetric quantities applied to patient undergoing routine chest examinations by computed tomography

Natália Barbosa Gonzaga 01 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O sistema de proteção radiológica estabeleceu um padrão para proteger as pessoas contra os efeitos danosos causados pela radiação ionizante tendo por base os princípios da justificação, otimização e limitação de dose. O aumento do uso das radiações em medicina e, consequentemente, dos riscos associados, promoveu a discussão sobre a proteção de pacientes. A tomografia computadorizada (TC) é uma das técnicas em radiodiagnósticos que mais contribui com a exposição do paciente e que requer esforços de otimização. Níveis de referência em radiodiagnóstico (NRD) em termos de grandezas dosimétricas foram estabelecidas em muitos países; no Brasil, os NRD ainda estão em fase de investigação, já que a cultura de proteção de pacientes ainda não é muito forte. O objetivo deste trabalho foi estudar as grandezas dosimétricas associadas à pacientes submetidos a exames de tórax rotina por TC, que são o índice de kerma no ar ponderado (CW) e volumétrico (CVOL), o produto kerma no ar comprimento (PK,L), a dose equivalente em órgãos (HT) e a dose efetiva (E). Os programas computacionais ImPACT CT, CT Expo e ImpactDose, foram usados para cálculos das doses, relativas aos protocolos de exames de tórax rotina em 19 tomógrafos amostrados. O CT Expo foi selecionado e validado através de medidas experimentais em três tomógrafos com dosímetros termoluminescentes, câmara de ionização tipo lápis, objeto simulador antropomórfico físico e objeto simulador de tronco padrão. Os resultados experimentais e calculados indicaram diferenças de até 97% nos valores de HT e E e adequada concordância para CW, CVOL e PK,L. Os dados referentes aos 19 tomógrafos foram comparados com os NRD adotados em outros países e evidenciaram que os NRD locais para exames de tórax rotina em TC podem ser estabelecidos menores que àqueles, contribuindo para aumentar a proteção radiológica do paciente. / The radiological protection system has established a standard to protect persons against the harmful effects caused by ionizing radiation that is based on the justification, optimization and dose limitation principles. The increasing use of radiation in medicine and the related risks have stressed the discussion on patient radiation protection. The computed tomography (CT) is the diagnostic radiology technique that most contributes to patient doses and it requires optimization efforts. Diagnostic reference levels (DRL) has been established in many countries in terms of CT dosimetric quantities; in Brazil, the DRLs are still under investigation since the culture of patient protection is not very strong yet. The objective of this work was to investigate the dosimetric and protection quantities related to patients undergoing CT routine chest examinations. The ImPACT CT, CT Expo and ImpactDose softwares were used for calculations of the weight and volumetric air-kerma indexes (CW and CVOL), the air kerma length product (PK,L), organ equivalent dose (HT) and the effective dose (E) for CT routine chest protocols in 19 tomographs in Belo Horizonte city. The CT Expo was selected to be validated against experimental measurements in three hospitals with thermoluminescent dosimeters and CT pencil ionization chamber in anthropomorphic and standard CT body phantoms. Experimental and calculated results indicated differences up to 97% for HT and E and acceptable agreement for CW ,CVOL and PK,L. All data from 19 tomographs showed that local DRLs for CT routine chest examinations may be chosen smaller than DRLs adopted in other countries; this would contribute to increase the radiological protection of patients.
88

Levantamento das curvas de isodose de sementes de 125I utilizando filmes fotográficos / Levantamento das curvas de isodose de sementes de 125I utilizando filmes fotográficos / Levantamento das curvas de isodose de sementes de 125I utilizando filmes fotográficos

Giovano Camargos da Silva 18 January 2013 (has links)
Nenhuma / A braquiterapia é uma modalidade de radioterapia em que a fonte radioativa é colocada em contato com o tecido a ser tratado. Na braquiterapia intersticial são utilizadas pequenas fontes radioativas seladas, denominadas sementes. A busca por novos modelos de sementes é constante. O CDTN desenvolveu parcialmente um protótipo para tratamento de braquiterapia que consiste de uma matriz cerâmica porosa capaz de incorporar diferentes radionuclídeos. A etapa seguinte ao desenvolvimento de um novo tipo de semente consiste na sua caracterização dosimétrica, que deve ser realizada em concordância com determinados padrões internacionais. Uma metodologia prática, que utiliza filmes fotográficos foi desenvolvida em um trabalho prévio de mestrado do CDTN para caracterizar parcialmente sementes de braquiterapia e avaliar possíveis problemas que podem ocorrer nas fases iniciais do desenvolvimento de novas sementes, tais como baixa taxa de incorporação, que se traduz numa baixa dose depositada ou uma incorporação não homogênea, que resultaria numa deformação espacial do campo de radiação (anisotropia). Essa metodologia foi agora aprimorada e utilizada na obtenção das curvas de isodose de sementes de iodo-125, na obtenção da curva de calibração dos filmes e nas estimativas de dose em meios com diferentes níveis de atenuação da radiação, assim como para diferentes distribuições espaciais de sementes. Como o protótipo da semente do CDTN não foi totalmente finalizado utilizou-se, neste trabalho, como referência, uma semente comercial de iodo-125. A metodologia mostrou-se sensível, podendo ser utilizada para sementes com baixa atividade. A utilização dos filmes fotográficos permite visualizar, caso existam, problemas de incorporação do material radioativo, o que pode ocorrer até mesmo em sementes comerciais. Portanto, o método mostra-se útil para uma verificação rápida de sementes antes de serem utilizadas em pacientes. / Brachytherapy is a form of radiotherapy where a radioactive source is placed in contact with the tissue to be treated. In interstitial brachytherapy, small radioactive sealed sources are used, which are called seeds. The search for new types of seeds is constant. CDTN has partially developed a prototype for brachytherapy treatment consisting of a porous ceramic matrix capable of incorporating different radionuclides. The next step of developing a new type of seed is its dosimetric characterization, which must be performed in accordance with certain international standards. A practical methodology that uses photographic film was developed in a prior masters work accomplished at CDTN to characterize partially brachytherapy seeds and evaluate possible problems that can occur in the early stages of new seeds development, such as low incorporation rate, which translates in a low dose deposition or a inhomogeneous incorporation, resulting in a space radiation field deformation (anisotropy). This method has now been improved and used in obtaining the iodine-125 seeds isodose curves, in the the film calibration curve obtainment and dose values estimates in mediums with different radiation attenuation levels as well as different seeds spatial distributions. As the CDTNs prototype seed has not been fully finalized, in this work, it was used as reference, a commercial seed of iodine-125. The method was sensitive and can be used for seeds with low activity. The use of photographic film allows the visualization of radioactive material incorporation problems, if any, which can occur even in commercial seeds. Therefore, the method shows to be useful for a quick check of seeds before they are used in patients.
89

Estudo do espectro das massas de blingagem de cor em QDC na rede a temperatura finita. / Study of the spectrum of color screening masses in lattice QCD to finite temperature.

Ricardo de Souza Costa 02 July 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho estudamos o espectro das massas de blindagem mais baixas em teorias do tipo Yang_Mills na rede.Utilizamos os grupos de calibre SU(2) e SU(3) em 2+1 e 3+1 dimensões. Os cálculos foram realizados perto da temperatura crítica da transição de fase confinamento-desconfinamento. Obtivemos valores para as razôes entre as massas consistentes com os valores previstos a partir de universidade. / In this work we study the spectrum of the lowest screening masses for Yang-Mills theories on the lattice. We used the gauge groups SU(2) and SU(3) in 2 + 1 and 3 + 1 dimensions. Calculations were done near the critical temperature of the confinement-desconfinement phase transition. We obtained values for the ratios of the screening masses consistent with predictions from universality arguments.
90

O vértice D*Dp usando as regras de soma da QCD / The D*Dp vertex using the QCD sum rules

Bruno Osório Rodrigues 03 March 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A física de partículas vem atualmente estudando tópicos como o plasma de quarks e glúons (QGP), o bóson de Higgs e a matéria escura, que requerem experimentos de colisões entre partículas cada vez mais energéticas. Para isso, são necessários aceleradores capazes de gerar partículas projéteis a cada vez mais altas energias, o que pode levar a uma nova física. Quando novos dados surgem nos laboratórios, novos processos são necessários para explicar estes dados e algumas vezes a estrutura interna das partículas envolvidas é desconhecida. Nos modelos teóricos, usados para descrever estes processos de espalhamento, é comum introduzir o fator de forma. O fator de forma é simplesmente uma maneira de simular a sub-estrutura das partículas envolvidas nestes processos com função da energia ou momento. A obtenção dos atores de forma pode ser feita usando o método conhecido como Regras de Soma da QCD (RSQCD). Neste trabalho, será estudado o vértice D*Dp usando as RSQCD, de modo que seja possível obter os seus fatores de forma e sua constante de acoplamento. Para isso, foram estudados os casos em que o méson ρ e o méson D estão fora de suas camadas de massa. O vértice D*Dp é muito importante para entender melhor o ρπ Puzzle, onde o méson Ј/ψ decai ρπ em com um branching ratio maior do que o esperado (este é um processo suprimido pela regra de OZI). Estudando este processo com graus de liberdade mesnicos, é possível escapar da regra de OZI, uma vez que o processo Ј/ψ→ DD → ρπ não é suprimido por OZI. Ao se fazer isso, aparecerá, entre outros, o vértice D*Dp . Este é um vértice que também aparece em outros decaimentos, como por exemplo X(3872) →Ј/ψp e B→Ј/ψD. Ao final do desenvolvimento, os resultados obtidos neste trabalho para o vértice D*Dp foram comparados com outros encontrados na literatura, se mostrando compatíveis com estes outros trabalhos. / The particle physics have been studying topics like the Quark-Gluon Plasma (QGP), Higgs boson and dark matter, which require experiments in heavy-ion collisions. Therefore, accelerators capable of generate high energy particle beams are necessary and may generate new physics. When new data arise in the laboratories, new processes are necessary to explain this data and sometimes, the internal structure of the involved particles is unknow or are virtual. In the theoretical models, used to describe this scattering processes, is common to introduce the form factors. The form factor is a way to simulate the sub-structure of the involved particles as function of energy or momentum. The form factor can be obtained using a method called QCD Sum Rules (QCDSR). In this work, the vertex D*Dp will be studied using the QCDSR, in order to obtain its form factors and coupling constant.The D*Dp vertex is very important to understand the ρπ Puzzle, where the Ј/ψ meson decays in ρπ with a branching ratio bigger than expected (this is a suppressed process by the OZI Rule). Studying this process with hadronic degrees of freedom, its possible to escape of the OZI rule, once the Ј/ψ→ DD → ρπ is not suppressed by the OZI rule. In this process, the D*Dp vertex is necessary. There are other processes where this vertex is necessary: X(3872)→Ј/ψp and B→Ј/ψD for example. In this work, was only possible to obtain results from the ρ off-shell diagram. This results were compared with others obtained in the literature.

Page generated in 0.0676 seconds