• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 380
  • 67
  • 42
  • 30
  • 24
  • 8
  • 7
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 701
  • 137
  • 89
  • 63
  • 50
  • 45
  • 44
  • 41
  • 40
  • 36
  • 35
  • 34
  • 34
  • 33
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
591

Polarimetry of the polarized hydrogen deuteride HDice target under an electron beam / Polarimétrie de la cible polarisée de deutérure d'hydrogène HDice sous un faisceau d'électrons

Laine, Vivien 21 November 2013 (has links)
L’étude de la structure du nucléon est un sujet actif de la recherche et un des objectifs majeurs du Thomas Jefferson National Accelerator Facility (Jefferson Lab). Dans cette optique et afin d’obtenir des résultats statistiquement significatifs, il est essentiel d’avoir une cible polarisée ayant à la fois une haute polarisation et une densité de matériel polarisé élevée. Cette thèse présente les principes et utilisations d’une cible de deutérure d’hydrogène (ou cible de HD) qui remplit les deux conditions précédemment énoncées. Bien qu’il ait été prouvé que la cible de HD pouvait être utilisée avec succès sous un faisceau de photons de haute intensité, il restait à montrer si elle pouvait résister un faisceau d’électrons de courant relativement élevé (nA). Dans ce but, la cible de HD a été testée pour la première fois dans son mode de “spin gelé” sous un faisceau d’électrons pendant l’expérience g14 dans le Hall B de Jefferson Lab en 2012. Deux méthodes de polarimétrie sont également décrites dans cette thèse : une par Resonance Magnétique Nucléaire appliquée à la cible de HD pendant les tests sous un faisceau d’électrons, et une autre utilisant la réaction de diffusion élastique d’un faisceau d’électrons sur une cible en utilisant des données élastiques sur l’hélium-3 prises en 2003 pendant l’expérience E97-110 dans le Hall A de Jefferson Lab. / The study of the nucleon structure has been a major research focus in fundamental physics in the past decades and still is the main research line of the Thomas Jefferson National Accelerator Facility (Jefferson Lab). For this purpose and to obtain statistically meaningful results, a highly efficient polarized target is essential. This means high polarization and high relative density of polarized material. This dissertation presents the principles and usage procedures of a Hydrogen Deuteride (HD) target that presents both such characteristics. Although the HD target has been shown to work successfully under a high intensity photon beam, it remained to be seen if the target could stand an electron beam of reasonably high current (nA). In this perspective, the HD target was tested for the first time in its “frozen spin” mode under an electron beam during the g14 experiment in the Jefferson Lab’s Hall B in 2012. Two methods of polarimetry are also discussed in this dissertation : one with Nuclear Magnetic Resonance of this HD target during the electron beam tests, and another with the elastic scattering of electrons off a polarized target by using data taken on helium-3 during the E97-110 experiment that occurred in Jefferson Lab’s Hall A in 2003.
592

Advanced microstructured semiconductor neutron detectors: design, fabrication, and performance

Bellinger, Steven Lawrence January 1900 (has links)
Doctor of Philosophy / Department of Mechanical and Nuclear Engineering / Douglas S. McGregor / The microstructured semiconductor neutron detector (MSND) was investigated and previous designs were improved and optimized. In the present work, fabrication techniques have been refined and improved to produce three-dimensional microstructured semiconductor neutron detectors with reduced leakage current, reduced capacitance, highly anisotropic deep etched trenches, and increased signal-to-noise ratios. As a result of these improvements, new MSND detection systems function with better gamma-ray discrimination and are easier to fabricate than previous designs. In addition to the microstructured diode fabrication improvement, a superior batch processing backfill-method for 6LiF neutron reactive material, resulting in a nearly-solid backfill, was developed. This method incorporates a LiF nano-sizing process and a centrifugal batch process for backfilling the nanoparticle LiF material. To better transition the MSND detector to commercialization, the fabrication process was studied and enhanced to better facilitate low cost and batch process MSND production. The research and development of the MSND technology described in this work includes fabrication of variant microstructured diode designs, which have been simulated through MSND physics models to predict performance and neutron detection efficiency, and testing the operational performance of these designs in regards to neutron detection efficiency, gamma-ray rejection, and silicon fabrication methodology. The highest thermal-neutron detection efficiency reported to date for a solid-state semiconductor detector is presented in this work. MSNDs show excellent neutron to gamma-ray (n/γ) rejection ratios, which are on the order of 106, without significant loss in thermal-neutron detection efficiency. Individually, the MSND is intrinsically highly sensitive to thermal neutrons, but not extrinsically sensitive because of their small size. To improve upon this, individual MSNDs were tiled together into a 6x6-element array on a single silicon chip. Individual elements of the array were tested for thermal-neutron detection efficiency and for the n/γ reject ratio. Overall, because of the inadequacies and costs of other neutron detection systems, the MSND is the premier technology for many neutron detection applications.
593

Helium-3 Magnetic Resonance Elastography of the lung / Elastographie des poumons par résonance magnétique de l’hélium-3 hyperpolarisé

Santarelli, Roberta 27 February 2013 (has links)
Selon l'American Lung Association, dans les dernières années, les maladies pulmonaires sont devenues la troisième cause mondiale de décès après les maladies cardiovasculaires et le cancer. Et il est prévu que la position augmente dans ce classement au cours des dix prochaines années. Les maladies pulmonaires telles que la broncho-pneumopathie chronique obstructive (BPCO) et la fibrose interstitielle affectent des millions de personnes dans le monde, tuant des milliers d'entre eux chaque année tandis que de nouveaux cas sont signalés. Aujourd'hui, il n'y a pas de diagnostic précoce des maladies pulmonaires. Celles-ci se manifestent essentiellement par une modification des propriétés viscoélastiques du parenchyme pulmonaire qui ne peut être détectée par les techniques usuelles appliquées généralement sur les autres organes. La tomodensitométrie par rayons X et la biopsie pulmonaire chirurgicale peuvent indiquer la maladie. Cependant, il n'est pas encore possible de prédire la progression de cette dernière ni de déterminer la durée optimale de la thérapie, ni encore d'explorer l'administration d'autres agents potentiellement moins toxiques que ceux utilisés de nos jours. Les causes et les mécanismes de la maladie ainsi que les facteurs génétiques associés ne sont pas encore déterminés. Les enjeux sociétal et médical sont énormes. Les propriétés viscoélastiques des tissus pulmonaires jouent un rôle clé dans la fonction-même de l'organe. Elles pourraient être des biomarqueurs pulmonaires très sensibles puisqu'elles dépendent de la structure des tissus, des conditions biologiques, et qu'elles sont considérablement altérées par la plupart des maladies pulmonaires comme le cancer, l'emphysème, l'asthme ou la fibrose interstitielle. Toutefois, l’auscultation et l’exploration tactile couramment utilisées ne peuvent pas localement les sonder in vivo. Dans ce travail de thèse, une nouvelle modalité a été développée pour cartographier les propriétés viscoélastiques du parenchyme pulmonaire afin de détecter, quantifier et classer les maladies qui les modifient. Cette nouvelle méthode d'imagerie, l’élastographie par résonance magnétique de l'hélium-3 hyperpolarisé, bénéficie de l'innocuité et de la sensibilité de la technique ainsi que de l'importance du signal d'hélium-3 hyperpolarisé dans les poumons.Tout d'abord, la technique a été validée sur des fantômes de poumons préservés de cochon. D'une part, les hypothèses de confinement du gaz et de l'indépendance à la composition du gaz qui sous-tendent l'élastographie IRM quantitative de l'hélium-3 ont été confirmées. D'autre part, la sensibilité de la technique a été éprouvée par rapport à l'inflation des poumons et à leur dépendance à la gravité. Puis, un mode d'excitation original a été développé et les protocoles d'acquisition IRM ont été optimisés pour réaliser l'élastographie IRM de l'hélium-3 in vivo. Les premières mesures de propagation d'ondes de cisaillement ont été obtenues à la fois dans des poumons de rat et d'humain. Les modules d'élasticité de cisaillement obtenus s'accordent assez bien avec les valeurs de rigidité obtenues ex vivo par les techniques alternatives. Ce travail ouvre une voie unique d'exploration in vivo de la physiopathologie pulmonaire. / According to the American Lung Association, for the last few years, lung diseases have become the third most common cause of death worldwide after cardiovascular disease and tumors, and it is expected to rise up the ranking position in the next ten years. Lung diseases such as Chronic Obstructive Pulmonary Disease and interstitial fibrosis affect millions of people worldwide, killing thousands of them every year while new cases are reported. Today, there is no early diagnosis of these pulmonary diseases. They effectively manifest by a modification of the viscoelastic properties of the lung parenchyma which cannot be detected by usual techniques that are applied to other organs. X-ray computer tomography and surgical lung biopsy can state the disease. However, it is not yet possible to predict its progression, to determine the optimal length of the therapy, or to explore the administration of other agents potentially less toxic than those used nowadays. Causes and mechanisms of the disease, associated genetic factors are not determined yet. The social and medical issues are huge. The viscoelastic properties of lung tissue play a key role in the basic function of the organ. They could be very sensitive pulmonary biomarkers as they depend on the tissue structure, the biological conditions, and they are dramatically altered by most lung diseases like cancer, emphysema, asthma, or interstitial fibrosis. However, current auscultation and tactual explorations fail to regionally probe them in vivo.In this PhD work, a new modality was developed to regionally measure the viscoelastic properties of the lung parenchyma in order to detect, quantify, and classify diseases that modify them. This new imaging approach, hyperpolarized helium-3 Magnetic Resonance Elastography (MRE), benefit from the innocuity and the sensitivity of the technique as well as from the huge hyperpolarized helium-3 signal in the lung. First, the technique was validated on preserved pig lung phantoms. On the one hand, the assumptions of gas confinement and gas content independence that support quantitative helium-3 MRE were assessed. On the other hand, the sensitivity of the technique was challenged with respect to lung inflation and gravity dependence. Second, original means of mechanical excitation were developed and MR acquisition protocols were optimized to perform helium-3 MRE in vivo. First measurements of shear wave propagation were achieved in both rat and human lungs. Resulting shear elasticity agrees fairly well with stiffness values found ex vivo by alternative measurement techniques. This work opens up promising insights into lung pathophysiology in vivo.
594

Evaluation de l’interaction fluide-structure dans les Voies Aériennes Supérieures par Imagerie par Résonance Magnétique / Evaluation of the upper airway fluid/structure coupling using magnetic resonance imaging during a breath cycle

Hagot, Pascal 24 February 2015 (has links)
Le Syndrome d’Apnée Obstructive du Sommeil affecte 4 à 6 % de la population en France soit près de 3 millions de personnes. Toutefois, les techniques de diagnostic usuelles ne permettent pas de déterminer de façon précise les sites d’occlusion ni de décrire les interactions fluide-paroi qui jouent un rôle important dans les processus de fermeture des voies aériennes supérieures. Au cours de ce travail, un ensemble d’outil a été mis en œuvre pour explorer les mécanismes sous-jacents conduisant à une apnée obstructive. La détermination géométrique et la caractérisation mécanique des voies aériennes supérieures, d’une part, la mesure des écoulements dans ces dernières, d’autre part, ont été réalisées par imagerie par résonance magnétique de l’hydrogène, pour les tissus, de l’hélium-3 et du fluor-19 pour les gaz. Les données obtenues ont été exploitées tout d’abord dans un modèle numérique statique pour estimer les lois d’état locales et caractériser la compliance des voies aériennes supérieures, puis, dans un modèle monodimensionnel, prenant en compte l’interaction fluide-structure et la limitation de débit au cours de l’inspiration, pour localiser les sites potentiellement responsables d’un éventuel collapsus. Par ailleurs, les écoulements de gaz d’hélium-3 et d’hexafluorure de soufre ont été simulés afin de déterminer le potentiel de ces deux modalités d’imagerie de gaz pour l’étude des obstructions des voies aériennes. La faisabilité d’une imagerie statique et dynamique par résonance magnétique du fluor a été démontrée. Avec une densité du gaz traceur bien plus importante, cette dernière technique présente une plus grande sensibilité à l’obstruction. Cette thèse ouvre ainsi une nouvelle voie de diagnostic et de guide thérapeutique personnalisé pour ce syndrome. / Obstructive Sleep Apnea (OSA) is a common disorder occurring in almost 3 million French people. However, current diagnosis methods are not sufficient to precisely define obstructing sites and doesn't take into account the fluid structure coupling which plays an important role during upper airway closing. During this thesis, we developed a series of tools exploring upper airway closing process. On the one hand, a screening tool of the structure and the mechanical properties of the upper airway, and on the other hand, a screening tool exploring with dynamic images of inert gases flow into the upper airway, were obtained using conventional hydrogen MRI coupled to magnetic resonance elastography (MRE) and helium-3 or fluor-19 gases MRI, respectively. Geometric and biomechanical data obtained using MRI/MRE are injected into a numerical model given the compliance and the state law of upper airway. Contributions of anatomical restriction on airway collapse are also investigated using a multi-compartmental two-dimensional fluid structure interaction model during a breath inspiration to predicted airway mechanical changes and collapse pressures. Furthermore, helium 3 and sulfur hexafluoride flow was modeled at steady state using commercial finite volume software to evaluate potential feasibility to image upper airway collapsibility during OSA. First dynamic MR imaging using sulfur hexafluoride (SF6) was obtained showing the feasibility of this technique. Using SF6, 6 times denser than air, shows a higher sensibility to upper airway obstruction. This thesis opens a new imaging modality to probe and to diagnose upper airway obstruction.
595

Études par spectroscopie EELS de nanobulles d'hélium et de nanoparticules bimétalliques or-argent (Au@Ag) / Study by EELS of helium nano-bubbles and gold-silver nanoparticles (Au@Ag)

Attouchi, Farah 14 November 2014 (has links)
Ce travail de thèse porte sur l'exploitation de la spectroscopie des pertes d'énergie des électrons,(EELS) résolue spatialement pour l'étude de systèmes de dimensions nanométriques. Cette technique étant réalisée avec un microscope électronique en transmission et à balayage, on parle d'expérience STEM-EELS dont le principal avantage est de permettre à la fois une caractérisation morphologique à l'échelle nanométrique et l'accès à une grande variété d'informations sur les propriétés physiques et chimiques des systèmes étudiés. Nous présentons ainsi deux cas d'étude portant sur : des nanobulles d'hélium confinées dans des matrices à base de fer et des nanoparticules métalliques or-argent de structure coeur- coquille. Ces deux études se basent sur le couplage entre imagerie microscopique à l'échelle nanomètrique et spectroscopie EELS en perte proche (Low-loss EELS).La première étude permet de sonder les densités et les pressions des bulles d'hélium en fonction de leur tailles en s'appuyant sur la détection et l'étude, bulle par bulle, du seuil K de l'hélium. Les résultats sont globalement en accord avec d'autres études dans le domaine, mais des densités très basses en hélium (<10 at nmˉ³) ont été mesurées de façon fiable pour la première fois.la deuxième étude concerne l'exploration des propriétés plasmoniques des nanoparticules bimétalliques Au@Ag en sondant les énergies et les localisations des modes plasmon de surface. On trouve un accord excellent entre les expériences et les calculs par éléments finis pour les positions des modes plasmon. La coquille en Ag semble déterminer leurs énergies, avec le coeur en Au ayant apparemment peu d'effet.Une part importante de ce travail concerne le développement des méthodologies d'acquisition et de traitement des données. Tout particulièrement l'utilisation des techniques d'analyses mutivariés (MVA) pour améliorer la détection de l'hélium dans les bulles. / This thesis describes the application of high spatial resolution electron energy-loss spectroscopy (EELS) to the nanometre scale analysis of two rather di#erent types of sam- ple. EELS performed in the scanning transmission electron microscope (STEM) is known as STEM-EELS and offers the possibility of performing morphological characterisations simultaneously with access to a wide variety of information on the physical and chemical properties of the systems under study. Our two areas of study are nano-bubbles of helium in iron-based alloys and core-shell Au-Ag nano-particles. Both systems are studied via electron microscopic imaging and low-loss EELS (i.e. the spectral range below 50 eV). In the first case the helium densities and pressures in the bubbles are measured as a function of their size and the conditions in which they are generated, via the examination of the intensity and spectral position of the He-K excitation. The results are in broad agreement with othe studies in the field, but particularly lowhelium densities (< 10 at nmˉ³) have been reliably measured here for the first time.The second case concerns the exploration of the bi-metallic nano-particles plasmonic properties via the study of the surface plasmon mode energies and spatial localisations. Excellent agreement is found between experiment and finite element calculations for the plasmon modes. The outer Ag shell essentially fixes their energies, the Au core apparently having little effect.An important part of this work concerns the application of novel acquisition and data analysis methods. In particular the use of multivariate statistical analysis (MVA) is shown to facilitate the detection and quantification of helium in the bubbles.
596

Caracterização e modelagem dos fenômenos anisotrópicos do colágeno após irradiação com Laser polarizado de emissão vermelha / Caracterization and modelling of collagen anisotropical phenomenons after irradiation with red emission polarized Laser

Silva, Daniela de Fatima Teixeira da 26 March 2007 (has links)
O colágeno é a forma funcional de um oligômero biológico, cujos monômeros são aminoácidos quirais. Tecidos ricos em colágeno são estruturas opticamente anisotrópicas, birrefringentes e não-lineares. O objetivo deste trabalho foi caracterizar o colágeno tipo I não irradiado e após irradiação com laser de He-Ne polarizado, utilizando a microscopia de polarização para investigação da birrefringência, e a geração de segundo harmônico (GSH) para análise da susceptibilidade não-linear. Doze ratos Wistar foram divididos em quatro grupos, de acordo com as idades: 34, 48, 62 e 76 dias. Os grupos receberam, respectivamente, 1; 5; 9 e 13 irradiações de D= 1J/cm2, durante 46s, no tendão de Aquiles que, aleatoriamente, foi escolhido ser o direito ou esquerdo. Os animais foram então sacrificados e os tendões extraídos para a preparação das amostras. Para a microscopia de polarização foram obtidos cortes com 8&mu;m de espessura, e as birrefringências de forma e intrínseca foram avaliadas. Para a GSH foi utilizado um laser de Ti:Safira (150fs) com 76MHz de taxa de repetição, diâmetro do feixe &phi;= 40&mu;m, comprimento de onda central &lambda;= 800nm e &Delta;&lambda;= 10nm e Pp= 110mW. Um polarizador linear foi posicionado no caminho do feixe. Duas objetivas foram utilizadas para focalizar e coletar a radiação incidente e emergente da amostra, respectivamente. Um analisador, também linear, foi introduzido logo após a objetiva coletora. Um filtro absorvedor na faixa infravermelha do espectro eletromagnético, mas transmissor na faixa azul, foi utilizado para garantir que apenas &lambda;= 400nm era medido. A razão, &rho;, entre dois tensores de hiperpolarizabilidade independentes foi estudada. As amostras irradiadas apresentaram maior birrefringência (&Delta;n) e maior susceptibilidade não-linear (&rho;), em comparação com as não irradiadas. Estes resultados indicam que o laser de He-Ne polarizado alinha as fibrilas de colágeno ao longo eixo do tendão. / The collagen is the functional form of a biological oligomer whose monomers are chiral amino acids. Tissues filled up of collagen are anisotropic optically structures, birefringent and nonlinear. The purpose of this study was characterizing nonirradiated and polarized He-Ne laser irradiated type I collagen using polarized light microscopy to investigate the birefringence and the second harmonic generation (SHG) to analyze the nonlinear susceptibility. Twelve Wistar rats were alienated into four groups according to the ages: 34, 48, 62 and 76 days. The groups received, respectively, 1; 5; 9; and 13 irradiations of D= 1J/cm2 during 46s on Achilles tendon, which was chosen randomly as right or left. Thereafter, the animals were sacrificed and the tendons were extracted to prepare the specimens. For polarized light microscopy, eight-&mu;m sections were obtained to evaluate the form and intrinsic birefringences. For SHG, it was used a Ti:Safira (150fs) laser at a repetition rate of 76MHz, beam diameter of &phi;= 40&mu;m, wavelength of &lambda;= 800nm and &Delta;&lambda;= 10nm and Pp= 110mW. The beam passed through a linear polarizer and two microscope objectives were used to focalize and collect the incident and emergent radiation, respectively. A second linear polarizer was placed after of collecting objective. An infrared absorber and blue transmitter filter was used a sure that only &lambda;= 400nm was measured. The ratio, &rho;, between two hyperpolarizability tensors was studied. The irradiated samples presented higher birefringence (&Delta;n) and nonlinear susceptibility (&rho;) when compared to nonirradiated samples. These results indicate that a polarized He-Ne laser aligns the collagen fibrils to the long tendon axis.
597

Pomeraj spektralnih linija helijuma u gustoj niskotemperaturnoj plazmi / Stark shift of neutral helium lines in low temperature dense plasma

Gajo Teodora 24 February 2017 (has links)
<p>Izmereni su Stark-ovi pomeraji maksimuma 8 spektralnih linija neutralnog helijuma u gustoj niskotemperaturnoj plazmi impulsnog luka. Osobine izvora plazme, sem postizanja visoke elektronske koncentracije, obezbeđuju relativno jednostavan način određivanja Stark-ovog pomeraja. Izvr&scaron;ena je dijagnostika plazme, pri čemu je određena elektronska koncentracija u intervalu od (6.2 &minus; 70) &middot; 10<sup>22</sup> m<sup>&minus;3</sup> i elektronska temperatura u intervalu (16400 &minus; 21400) K. Eksperimenatlne vrednosti Stark-ovih pomeraja upoređene su sa do sada objavljenim eksperimentalnim rezultatima kao i sa rezultatima teorijskih pristupa. Proveren je uticaj Debye-evog ekraniranja na pomeraj ovih linija. Dobijeni rezultati ukazuju na popravku Stark-ovog pomeraja uračunavanjem<br />uticaja Debye-evog ekraniranja, kao i potrebu korigovanja semiklasičnih teorijskih vrednosti elektronske sudarne polu-polu&scaron;irine i pomeraja.</p> / <p>The results of an experimental study of the Stark shifts AB of 8 neutral helium lines are presented. The plasma sour-ce was a linear pulsed arc with plasma electron&nbsp; density in the range (6.2 &minus; 70) &middot; 10 <sup>22</sup> m<sup> &minus;3</sup> and plasma temperature in the range (16400 &minus; 21400) K. Details of the experimental setup that enables a relatively quick&nbsp; Stark shift determination technique is presented. The results of these measurements are presented together with the corresponding plasma parameters and compared to other experimental and theoretical data. The influence of Debye shielding is carefully examined from the semiclassical point of view. The comparison of experimental&nbsp; results obtained in this work with the semiclassical results suggests that Debye shielding has an important role on higher electron densities. Also, based on all the available experimental data, appropriate correction factors are suggested for the semiclassical Stark shift calculations for the examined lines.</p>
598

Création et caractérisation d’une source ajustable de paires d’atomes corrélés / Creation and characterization of a tunable source of correlated atoms pairs

Ruaudel, Josselin 11 December 2013 (has links)
Ce mémoire de thèse décrit la création expérimentale et la caractérisation d'une source de paires d'atomes corrélés. Cette source ajustable repose sur l'utilisation du mélange à quatre ondes dans un réseau optique. Les paires ainsi créées sont similaires aux paires de photons produites par conversion paramétrique et ouvrent la porte à la réalisation d'expériences élaborées d'optique atomique quantique. En plaçant un condensat de Bose-Einstein dans un réseau en mouvement, les conditions d'accord de phase sont vérifiées et des atomes jumeaux sont alors produits spontanément. Grâce à un détecteur d'atomes uniques résolu à trois dimensions nous avons pu caractériser la source de paires obtenue. Nous avons ainsi étudié en profondeur les conditions d'accord de phase, prouvant que les atomes sont diffusés de manière préférentielle dans deux fines classes de vitesses qui conservent l'impulsion et l'énergie. En modifiant la vitesse et la durée du réseau par rapport aux atomes, il est possible de choisir les modes de sorties et leurs populations ce qui rend ce processus ajustable. De plus, nous avons pu mettre en évidence l'importance des interactions et en particulier des effets de champ moyen qui viennent modifier la conservation de l'énergie. La détection d'atome unique permet également d'étudier les propriétés statistiques des atomes jumeaux, nous avons ainsi pu mettre en évidence de fortes corrélations entres les atomes issus d'une même paire. Nous avons également observé une réduction sous le bruit de grenaille du bruit sur la différence du nombre d'atomes dans les modes corrélés. Cette réduction est une indication forte du caractère non classique des paires produites / This thesis describes the experimental realization and characterization of a source of pairs of correlated atoms. This tunable source is based upon four waves mixing in an optical lattice. The created atomic pairs are similar to photon pairs made by parametric down conversion and open the way toward more elaborate quantum atom optic experiments. By placing a Bose-Einstein condensate in a moving optical lattice the phase matching conditions are fulfilled and twins atoms are spontaneously produced. Thanks to a single atom detector with three-dimensional resolution, we were able to characterize our source of pairs. By studying the phase matching conditions, we proved that the atoms are preferentially produced in two narrow velocity classes conserving both momentum and energy. By modifying the duration and the velocity of the lattice with respect to the atoms, one can tune the output modes and their populations providing a fully tunable process. Moreover, we have demonstrated the important effect of interactions -especially of mean field effects- that modifies the energy conservation. The single atom detection provided also a convenient way to look at statistical properties of the twins atoms: we have demonstrated strong correlation between atoms from the same pair and also we have observed a reduction below the shot noise of the noise on the number of atoms in correlated modes. Such a reduction is a strong indication of the non-classical nature of the produced atomic pairs.
599

A New Metastable Helium Machine : An Investigation into the Attributes of Trapping, Cooling and Detecting Metastable Helium / machine pour métastable hélium : Une enquête sur les attributs de piégeage, de refroidissement et de détection de métastable hélium

Hoendervanger, Lynn 03 October 2014 (has links)
Cette thèse décrit le travail accompli au cours des trois dernières années sur la nouvelle expérience d’Hélium métastable de l'Institut d'Optique à Palaiseau.Le premier chapitre décrit une étude visant à améliorer à la fois l'efficacité et la précision du système de détection par galettes à micro-canaux (MCP). Nous avons fait des mesures avec des galettes recouvertes d'une couche d'or sur la face avant, obtenant un accroissement de l'efficacité de détection mais également une réduction de la précision. L'ajout d'une tension intermédiaires entre les deux galettes empilées a au contraire améliorer à la fois l'efficacité et la précision des MCP, en l’absence d’une couche d’or.Le deuxième chapitre est consacré à la construction de l'appareil expérimental pour le refroidissement et le piégeage d’atomes. L’excitation de l'état fondamental de l’Hélium à l'état métastable est décrite, ainsi que la collimation et le refroidissement ultérieur par Zeeman lent du faisceau atomique chaud résultant. Le faisceau ralenti est alors capturé dans un piège magnéto-optique (PMO), dans lequel nous avons capturé 8x108 atomes.Dans le troisième chapitre une étude originale du refroidissement Doppler tridimensionnel dans un PMO et une mélasse désaccordée vers le rouge de la transition atomique est discutée. L’atome d’Hélium métastable est unique et ses propriétés ont permis une telle étude. En effet, les faibles densités atomiques impliquent qu’il n'y a pas de diffusion multiple de photons d’une part, et la faible masse et la faible largeur de la transition 23S1 -> 23P2 rend inefficace les processus de refroidissement sous la limite Doppler. Ces conditions nous ont permis d’observer pour la première fois à trois dimensions un gaz refroidit dans le régime Doppler.Le quatrième chapitre présente une étude sur les collisions dans un piège magnéto-optique d’Hélium métastable. Les collisions Penning induites par la lumière, en particulier à des intensités élevées et à des fréquences proches de la fréquence de transition, sont responsables de pertes élevées d’atomes piégés. Nous mesurons le coefficient de taux associé à ces pertes, Ksp = 2,8 ± 0,4 x 10-7cm3/ s. / This thesis describes the work done over the past three and a half years on the new metastable helium experiment at the Institut d'Optique in Palaiseau. In the first chapter it describes a study to improve both the efficiency and the accuracy of the Microchannel Plate (MCP) detection system. We have experimented with adding a gold layer on the top of the input plate, something that we have found increases the efficiency but also decreases the accuracy. The addition of a voltage between the two stacked plates has been shown to both raise the efficiency and improve the accuracy in non-coated MCPs.The second chapter is devoted to the construction of the experimental apparatus. Here the excitation of ground state helium to its metastable state is described, as well as the subsequent collimation and cooling by Zeeman slower of the resulting hot atomic beam. The slowed beam is then captured in a Magneto-Optical Trap, in which we have captured 8x108 atoms.In the third chapter an original study on three-dimensional Doppler cooling in a red-detuned molasses and in the Magneto-Optical trap is presented. The metastable helium system is unique as there is no multiple scattering of photons and there are no sub-Doppler effects. This allows for a never before seen experimental realisation of pure Doppler cooling theory. The fourth chapter describes a study on collisions in a magneto-optical trap of metastable helium. Light-induced Penning collisions are responsible for high trap losses at high intensities and at frequencies close to the transition frequency. We measure the constant rate coefficient to Ksp = 2.8 ± 0.4 x 10-7cm3/s.
600

Evolution microstructurale du fer pur et d’un alliage Fe-Cr sous irradiation avec injection simultanée d’hélium : étude expérimentale et modélisation / Microstructural evolution of pure iron and a Fe-Cr alloy under irradiation with simultaneous injection of helium : experimental study and modeling

Brimbal, Daniel 02 December 2011 (has links)
Les aciers ferrito-martensitiques sont d’excellents candidats potentiels en tant que matériaux de structure dans les futurs réacteurs de fusion. A ce titre, ils devront résister à des flux intenses de neutrons de 14 MeV qui créeront des cascades de déplacements atomiques et des produits de transmutation tels que l’hélium. Afin de mieux comprendre le comportement de base de ces aciers sous irradiation en présence d’hélium, nous avons étudié les effets de l’hélium et ceux du chrome dans le cadre de ce travail de thèse. Du fer pur et un alliage modèle Fe-5,4%pds Cr ont ainsi été irradiés dans la plateforme JANNuS à 500°C en bi-faisceau avec des ions Fe+ et He+ et en mono-faisceau avec des ions Fe+. L’utilisation de cette plateforme a permis de suivre l’évolution du dommage jusqu’à des doses faibles (1 dpa) et de caractériser la microstructure après irradiation à forte dose (100 dpa). Elle a également permis l’observation in situ dans un MET couplé à deux accélérateurs des effets cinétiques d’implantation/irradiation. La nature et la répartition des défauts d’irradiation ont été déterminés : ce sont essentiellement des boucles de dislocations de vecteur de Burgers de type a<100> et des cavités/bulles. Nous avons montré que la co-implantation d’hélium et l’addition de chrome réduisent la mobilité des boucles. Par ailleurs, avec ou sans hélium, l’addition de chrome réduit le gonflement dans toutes les conditions étudiées. De plus, dans le fer pur irradié avec hélium, un phénomène original de germination hétérogène de cavités/bulles dans les plans des boucles a été mis en évidence. Enfin, nous avons également utilisé le code de dynamique d’amas CRESCENDO pour interpréter les résultats expérimentaux dans le fer pur irradié avec hélium. / Ferritic-martensitic steels are excellent potential candidates for a use as structural materials in future fusion reactors. For this application, they will have to withstand high fluxes of 14 MeV neutrons that will create atomic displacement cascades and transmutation reactions which will produce large quantities of helium. In order to understand the basic mechanisms under irradiation with helium, we have studied the effects of helium and those of chromium. Pure iron and a Fe-5.4 wt. % Cr model alloy were irradiated at the JANNuS platform in dual-beam mode with Fe+ and He+ ions and in single-beam mode with Fe+ ions at 500ºC. This platform enabled us to follow the evolution of damage up to low doses (1 dpa) and to characterize the microstructure at high doses (100 dpa). It also allowed us to observe in situ irradiation/implantation kinetic effects in a TEM coupled to two accelerators. The nature and distribution of irradiation defects was determined: they are essentially dislocation loops with a<100> Burgers vectors and cavities/bubbles. We have demonstrated that the co-implantation of helium and the addition of chromium both reduce the mobility of dislocation loops. The addition of chromium reduces swelling for all the irradiation conditions studied, with or without helium. In pure iron irradiated with helium, an original phenomenon was discovered for the first time: cavities/bubbles nucleate heterogeneously on the planes of the dislocation loops. We have also interpreted our experimental results in pure iron irradiated with helium using the cluster dynamics code CRESCENDO.

Page generated in 0.0349 seconds