• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 321
  • 15
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 341
  • 217
  • 104
  • 75
  • 72
  • 66
  • 61
  • 57
  • 43
  • 40
  • 39
  • 38
  • 37
  • 37
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Influência dos barorreceptores e da pressão arterial na resposta cardíaca à hipertensão renovascular em ratos / Influence of baroreceptors and of arterial blood pressure in cardiac responses to renovascular hypertension in rats

Kaleizu Teodoro Rosa 15 August 2008 (has links)
No presente estudo, duas importantes situações foram abordadas no intuito de se melhor entender os mecanismos homeostáticos dos pressorreceptores na gênese da hipertrofia cardíaca em resposta à hipertensão renovascular: o efeito do tempo de clipe na artéria renal e o efeito dos níveis pressóricos e da variabilidade da pressão arterial. O curso temporal mostrou que, antes mesmo da instalação da hipertensão, há alteração da morfologia cardíaca, qual seja o desenvolvimento de uma hipertrofia ventricular excêntrica e, como forma de mecanismo compensatório, um aumento da expressão de algumas proteínas da homeostase do cálcio (fosfolambam fosforilada pela serina-16 e corrigido pelo fosfolambam total em 100% e fosfolambam fosforilado pela treonina-17 e corrigido pelo fosfolambam total em 54%). Uma vez instalada a hipertensão, observou-se um remodelamento ventricular esquerdo para o tipo concêntrico, com prejuízo da função diastólica e um desbalanço do sistema nervoso autonômico, com aumento da atividade simpática, observado pelo aumento da razão dos componentes de baixa freqüência (LF) e alta freqüência (HF) no tacograma (0,44 ± 0,10 vs. 0,20 ± 0,03 nos controles). A análise do efeito da pressão arterial e da variabilidade da pressão arterial mostrou uma correlação positiva com o grau de hipertrofia ventricular esquerda (r=0,76, p<0,01). A secção cirúrgica dos pressorreceptores somada à implantação do clipe na artéria renal mostrou adaptações cardiovasculares em níveis semelhantes (mesmo nível de hipertensão) e, por vezes maiores (modulação simpática para o coração e para os vasos, hipertrofia ventricular esquerda e disfunção diastólica), ao grupo cuja artéria renal foi estenosada e que permaneceu com os barorreceptores intactos. Estas respostas aconteceram num período de tempo três vezes menor na ausência do barorreflexo. Tais observações ressaltam o importante efeito homeostático do barorreflexo na gênese das respostas cardíacas adaptativas à hipertensão arterial / In the present study, two important situations were observed to evaluate the role of the baroreceptors in the genesis of cardiac hypertrophy in response to hypertension: the effect of the time-course of the clip in the renal artery and the effect of the level of arterial blood pressure (ABP) and blood pressure variability (ABPV). The time-course evaluation showed that even before hypertension was installed, cardiac alterations could be observed, as a left ventricular eccentric hypertrophy. Compensatory mechanisms, such as an increase in some calcium homeosthatic proteins, could also be noticed (increase in phosphorilated phospholmaban at threonin-17 corrected by total phospholamban in 54% and increase in phosphorilated phospholmaban at serine-16 corrected by total phospholamban in 100%). However, once hypertension was established, left ventricle morphology changed to a concentric hypertrophy, accompanied by a diastolic dysfunction and enhanced sympathetic modulation, observed by relation between low-frequency component (LF) and high-frequency component (HF) at tachogram (0,44 ± 0,10 vs. 0,20 ± 0,03 in control group). ABP and ABPV analyses showed an important positive correlation with the degree of left ventricular hypertrophy (r=0,76, p<0,01). However, the absence of baroreceptors in one of the hypertensive groups, evoked the same cardiovascular alterations (same level of hypertension) or even worse (sympathetic modulation for heart and vessels, left ventricular hypertrophy and diastolic dysfunction) reached by the hypertensive baroreceptors-preserved group. These cardiovascular responses were observed in a period that correspond one third of time to the group with intact baroreflex. These observations lead us to conclude the importance of homeosthatic effects of the baroreflex in the genesis of cardiac responses to hypertension
202

Influência do polimorfismo do gene da ECA e do angiotensinogênio na hipertrofia miocárdica e melhora da capacidade funcional provocados pelo treinamento físico / Influence of angiotensinogen and ACE polymorphisms on myocardial hypertrophy and gain of aerobic capacity caused by exercise training in young individuals

Guilherme Barretto Alves 10 August 2007 (has links)
O sistema renina angiotensina (SRA) exerce um importante papel no controle do sistema cardiovascular, em especial na regulação da pressão arterial e homeostasia hidroeletrolítica do organismo, além de poder influenciar o crescimento celular e a proliferação, estimulando citocinas e fatores do crescimento. Diversos polimorfismos do SRA têm sido descritos. No entanto, o impacto dessa variação genética na expressão de fenótipos ainda é pouco conhecido. O objetivo desse estudo longitudinal foi investigar a influência do polimorfismo da enzima conversora da angiotensina (ECA) e do angiotensinogênio na hipertrofia cardíaca e no ganho de capacidade funcional provocados pelo treinamento físico em indivíduos jovens e saudáveis, homozigotos para os alelos D e I do polimorfismo da ECA e para os alelos M e T do polimorfismo do angiotensinogênio. Completaram o estudo 83 policiais militares (26± 4,5 anos), genotipados para o polimorfismo da ECA (II, n=18 e DD, n=32) e do angiotensinogênio (MM, n=16 e TT, n=25). A morfologia do coração foi avaliada pela ecocardiografia e a capacidade funcional pela ergoespirometria antes e após 17 semanas de treinamento físico aeróbio (50 a 80% VO2 pico). O consumo de oxigênio de pico (VO2 pico) e o índice de massa do ventrículo esquerdo (IM) antes do treinamento físico não eram diferentes entre os quatro grupos estudados. O treinamento físico aumentou significativamente e semelhantemente o VO2 pico nos indivíduos homozigotos II e DD (P<0,05 e P<0,05, respectivamente) e nos indivíduos homozigotos TT e MM (P<0,05 e P<0,05, respectivamente). O treinamento físico aumentou significativamente o IM nos indivíduos II e DD (P <0,05 e P, <0,05 respectivamente) e nos indivíduos TT e MM (P<0,05 e P <0,05 respectivamente). No entanto, o grau de hipertrofia ventricular nos indivíduos TT foi significativamente maior que nos indivíduos MM (P=0,04). A hipertrofia ventricular não foi diferente entre os indivíduos II e DD. Conclui-se, dessa forma, que a hipertrofia do ventrículo esquerdo provocada pelo treinamento físico é exacerbada em indivíduos homozigotos TT do gene do angiotensinogênio. O polimorfismo da ECA e do angiotensinogênio não influenciam o ganho de capacidade funcional provocado pelo treinamento físico. O polimorfismo da ECA não influencia a hipertrofia do ventrículo esquerdo provocada pelo treinamento físico. / The renin-angiotensin system (RAS) plays an important role in the blood pressure regulation and balance of plasma volume. Besides, it mediates cell growth and proliferation. Some RAS polymorphisms have been identified. However, the impact of these polymorphisms in phenotype expression is still little understood. We investigated the effects of long-term physical exercise on left ventricular mass and aerobic power in young healthy individuals homozygous for the D or I allele of the angiotensin-converting enzyme (ACE) polymorphism and M or T allele of the angiotensinogen polymorphism. Eighty three policemen (26± 4.5 years) completed the study. They were genotyped for the M235T gene angiotensinogen polymorphism (MM, n=16 e TT, n=25) and ACE gene insertion/deletion (I/D) polymorphism (II, n=18 e DD, n=32). The left ventricular morphology was evaluated by means of echocardiography and functional capacity by cardiopulmonary exercise test before and after 17 weeks of aerobic physical exercise (50 - 80% VO2 peak). VO2 peak and let ventricular mass index (LVMI) were similar among the four groups before physical training. Physical training significantly and similarly increased VO2 peak in homozygous II and DD groups (P<0.05 and P<0.05, respectively), and homozygous TT and MM groups (P<0.05 and P<0.05, respectively). Physical training significantly increased LVMI in II and DD groups (P<0.05 and P<0.05, respectively), and TT and MM groups (P<0.05 and P, <0.05 respectively). However, the LVMI in TT subjects was significantly greater increase than in MM subjects (P=0.04). The LVMI was not different between II and DD subjects. In conclusion, the left ventricular hypertrophy caused by physical training is exacerbated in homozygous TT subjects of angiotensinogen polymorphism. The ACE polymorphism and angiotensinogen polymorphisms do not influence the aerobic capacity gain caused by physical training. The ACE polymorphism does not influence the left ventricular hypertrophy caused by physical training.
203

Qualidade da carne de peito de frangos de corte in natura e processada acometidas por peito de madeira /

Oliveira, Rodrigo Fortunato de January 2019 (has links)
Orientador: Hirasilva Borba / Resumo: O objetivo deste estudo foi avaliar a qualidade física, química da carne e a histomorfometria das fibras musculares de peito amadeirado (PM), e submeter estas ao processo de maturação e produção de hambúrgures e linguiça frescal, com o intuito de obter uma aplicação industrial desta carne. O capítulo 1 aborda considerações gerais e revisão de literatura sobre o tema proposto. No capítulo 2 foram avaliadas as caracteristícas físicas, químicas e histológicas da carne de peito de frangos de corte acometidos pela miopatia PM. No capítulo 3 foram avaliados os possíveis efeitos da maturação por até sete dias sobre a qualidade da carne de peito de frangos de corte acometidos pelos diferentes graus de severidade da miopatia PM. No capítulo 4 foram avaliados a qualidade de linguiças tipo frescal fabricadas com carne de peito de frangos acometidos pelos diferentes graus de severidade da miopatia PM armazenadas por 28 dias. E no capítulo 5 foram avaliados a qualidade de hambúrgueres de frangos acometidos pelos diferentes graus de severidade da miopatia PM armazenados por 120 dias. As amostras cruas de frangos acometidos pelo grau severo da miopatia PM possuem qualidade física inferior comparada com a carne de frango normal, o que pode ser prejudicial ao processamento da carne. As carnes de grau severo da miopatia PM possui níveis superiores de docosa-hexaenoico e ácido araquidônico, além de menor teor de gordura que peitos normais. As análises histomorfométricas mostram que a miodegener... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the physical, chemical and meat quality and histomorphometry of the woody breast muscle fibers, and to submit them to the process of maturing and production of hamburgers and fresh sausages, in order to obtain an industrial application of this meat. Chapter 1 discusses general considerations and literature review on the proposed theme. In chapter 2 the physical, chemical and histological characteristics of the breast meat of broilers affected by PM myopathy were evaluated. In Chapter 3, the possible effects of maturation for up to seven days on the quality of breast meat of broilers affected by the different degrees of severity of PM myopathy were evaluated. Chapter 4 evaluated the quality of fresh sausages made with chicken breast meat affected by the different degrees of severity of PM myopathy stored for 28 days. And in Chapter 5, the quality of chicken burgers affected by different degrees of severity of PM myopathy stored for 120 days was evaluated. Raw chicken samples affected by the severe degree of PM myopathy have lower physical quality compared to normal chicken meat, which can be detrimental to meat processing. The severe meats of PM myopathy have higher levels of docosahexaenoic and arachidonic acid, and lower fat content than normal breasts. The histomorphometric analyzes show that the myocardial disease caused by PM myopathy presents muscle fiber hypertrophy as compensatory mechanism in the moderate and severe degrees ... (Complete abstract click electronic access below) / Doutor
204

Efeitos do treinamento resistido associado à restrição parcial de fluxo sanguíneo na força e hipertrofia de extensores do joelho em adultos saudáveis : uma revisão sistemática com metanálise e um estudo randomizado controlado /

Biral, Taíse Mendes January 2019 (has links)
Orientador: Franciele Marques Vanderlei / Resumo: Estudos sobre o treinamento resistido de baixa intensidade associado à restrição de fluxo sanguíneo (RFS) atualmente tem ganhado destaque, porém ainda existem lacunas que podem ser exploradas em relação aos seus efeitos fisiológicos quando associado a treinamentos excêntricos, principalmente na força e hipertrofia muscular. Objetivo: Realizar uma revisão sistemática com metanálise e um estudo aleatorizado controlado a fim de esclarecer os reais efeitos do TRBI associado à RFS nos desfechos de força, hipertrofia muscular e desempenho funcional, e se a RFS quando associada a treinamentos excêntricos de baixa e alta intensidade é capaz de aumentar as respostas desses desfechos dos extensores de joelho em homens adultos saudáveis. Métodos: A revisão sistemática foi registrada no PROSPERO (número do registro #CRD42018104065). Os estudos foram selecionados por meio de sete bases de dados. Todos os estudos incluídos foram avaliados quanto à qualidade metodológica, utilizando a Escala PEDro, bem como foi avaliada a qualidade da evidência. Somente ensaios clínicos randomizados que avaliaram a eficácia do treinamento com RFS na força e hipertrofia muscular dos músculos extensores de joelho em adultos do sexo masculino, saudáveis e/ou fisicamente ativos, com idade de 18 a 35 anos, contra algum grupo de intervenção foram considerados elegíveis. Todas as metanálises foram conduzidas por meio do software Review Manager – RevMan e descritos como diferenças médias padronizadas (standardized ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Studies on low intensity resistance training associated with blood flow restriction (RFS) are currently gaining prominence, however there are still gaps that can be explored in relation to their physiological effects when associated with eccentric training, especially in muscle strength and hypertrophy. Objective: To carry out a systematic review with meta-analysis and a randomized controlled study in order to clarify the real effects of TRBI associated with RFS on the outcomes of strength, muscle hypertrophy and functional performance, and whether RFS when associated with low and high intensity eccentric training is able to increase the responses of these knee extensor outcomes in healthy adult men. Methods: The systematic review was registered in PROSPERO (registration number # CRD42018104065). The studies were selected through seven databases. All included studies were assessed for methodological quality, using the PEDro Scale, as well as the quality of evidence was assessed. Only randomized controlled trials that assessed the effectiveness of RFS training on muscle strength and hypertrophy of knee extensor muscles in healthy, male and / or physically active adults, aged 18 to 35, against any intervention group were considered eligible. All meta-analyzes were conducted using the Review Manager - RevMan software and described as standardized mean differences (SMD) or mean differences (mean difference - MD) with 95% confidence intervals (CI). The randomized controlled study ... (Complete abstract click electronic access below) / Mestre
205

Avaliação experimental do metabolismo energético em dois protocolos de sobrecarga sistólica do ventrículo direito / Experimental evaluation of energy metabolism in two right ventricle systolic overload protocols

Atik, Fernando Antibas 16 March 2012 (has links)
Objetivo: Alterações do metabolismo energético tem sido identificadas em processos de hipertrofia miocárdica, sendo algumas consideradas benéficas, porém outras estão associadas a insuficiência cardíaca. O objetivo deste trabalho foi comparar a atividade de três enzimas do metabolismo energético em dois protocolos de sobrecarga sistólica do ventrículo direito (VD) num modelo experimental em cabritos. Métodos: 27 cabritos jovens foram divididos em três grupos: Sham (sem sobrecarga), Contínuo (sobrecarga sistólica constante) e Intermitente (4 períodos de 12 horas de sobrecarga sistólica, intercalados com 12 horas de descanso). Durante as 96 horas do protocolo, a sobrecarga sistólica foi ajustada a fim de atingir relação de pressão entre a aorta e o VD de 0,7. Medidas ecocardiográficas e hemodinâmicas foram realizadas antes e após o período de sobrecarga diariamente até o término do protoloco. Após o término do mesmo, os animais foram sacrificados a fim de obter dados morfológicos e a atividade máxima das enzimas Glicose 6 Fosfato Desidrogenase (G6PD), Hexoquinase (HK) e Lactato Desidrogenase (LDH). Resultados: Houve aumento de 92,1% e 46,5% nas massas do VD e septal no grupo Intermitente, respectivamente, quando comparado ao grupo Sham, enquanto que no grupo Contínuo houve incremento de 37,2% somente na massa septal. O VD e Septo dos grupos submetidos à sobrecarga sistólica contínua e intermitente do VD apresentaram um aumento discreto, porém significativo, do conteúdo de água (VD, p=0,0014; Septo, p=0,0004) em relação ao grupo Sham. Ao final do protocolo, foi observado um aumento significativo de 103,8% da espessura do VD no grupo Intermitente, comparado a um aumento de 38,4% do grupo Contínuo. Houve também dilatação ventricular significativa no grupo Contínuo ao longo do protocolo, quando comparado aos outros grupos (p<0,001). Piores índices de desempenho miocárdico ocorreram no grupo Contínuo no momentos 72 e 96 horas, quando comparados ao grupos Sham (P<0,039) e Intermitente (P<0,001). A razão da atividade máxima da G6PD do VD pelo VE revelou um aumento de 130,1% no grupo contínuo (p= 0,012) e de 39,8% no grupo Intermitente (p=0,764), quando comparados ao grupo Sham. O processo de hipertrofia aguda do VD não afetou a atividade enzimática da HK e LDH nos grupos estudados. Conclusões: Apesar de haver uma sobrecarga sistólica proporcionalmente menor no VD do grupo intermitente, a bandagem intermitente do TP promoveu maior hipertrofia do VD. A maior atividade da G6PD observada no grupo contínuo sugere maior produção de radicais livres via NADPH oxidase, haja vista que o ciclo das pentoses Fosfato incrementa a disponibilidade de NADPH citoplasmático, ocasionados pela maior demanda de um estímulo de sobrecarga miocárdica constante, um importante mecanismo de insuficiência cardíaca. Este estudo sugere que a preparação do ventrículo sub-pulmonar com a sobrecarga sistólica intermitente poderá proporcionar melhor resultado para a cirurgia de Jatene em dois estágios que a sobrecarga contínua / Objective: Altered energy metabolism has been identified in myocardial hypertrophy. Some processes are considered beneficial, whereas others are linked to heart failure. The purpose of this study was to compare the activity of three different energy metabolism enzymes in two different protocols of right ventricle (RV) systolic overload in young goats. Methods: 27 young goats were separated into three groups: Sham (no overload), Continuous (continuous systolic overload) and Intermittent (4 periods of 12-hour systolic overload, alternated with a 12-hour resting period). During a 96-hour protocol, systolic overload was adjusted to achieve a 0.7 RV / aortic pressure ratio. Echocardiographic and hemodynamic evaluations were performed before and after systolic overload every day postoperatively. After the study period, the animals were humanely killed for morphological and Glucose-6-phosphate dehydrogenase (G6PD), hexoquinase (HK) and lactate dehydrogenase (LDH) activity assessment. Results: There was a 92.1% and 46.5% increase in RV and septal masses of Intermittent group, respectively, as compared to Sham group, while Continuous systolic overload resulted in 37.2% increase of only septal mass. There was a small, but significant increase in water content in RV and septum of Intermittent and Continuous groups, as compared to Sham group (RV, p=0.0014; Septum, p=0.0004). At the end of protocol, it was observed a greater increase in RV thickness (103.8%) in Intermittent group, as compared to Continous group (38.4%). There was also a significant right ventricle dilatation in Continuos group along the protocol, as compared to the other groups (p<0.001). A worsening RV myocardial performance index occurred in the continuous group at 72 hours and 96 hours, compared with the sham (P<0.039) and intermittent groups (P<0.001). Compared to Sham, RV to LV G6PD activity ratio was elevated by 130.1% in Continuous group (p= 0,012) and by 39.8% in Intermittent group (p=0.764). The acute hypertrophic process in the RV did not altered the HK and LDH enzymatic activity among study groups. Conclusions: Despite of a proportional lesser exposure to systolic overload, intermittent pulmonary trunk banding promoted greater RV hypertrophy. This study indicates that continuous systolic overload for ventricle retraining causes upregulation and hyperactivity of myocardial G6PD. Since pentose phosphate pathway enhances cytosolic NADPH availability, this altered energy substrate metabolism can elevate levels of free radicals by NADPH oxidase, an important mechanism in the pathophysiology of heart failure. It suggests that Intermittent systolic overload may provide better results for 2-stage Jatene operation as compared to continuous protocol
206

Bandagem ajustável do tronco pulmonar: comparação de dois métodos de hipertrofia aguda do ventrículo sub-pulmonar / Adjustable pulmonary trunk banding: comparison of two methods of acute subpulmonary ventricle hypertrophy

Rodriguez, Miguel Alejandro Quintana 19 September 2006 (has links)
O preparo do ventrículo sub-pulmonar através da bandagem do tronco pulmonar (TP) pode ser aplicado nos pacientes portadores de transposição das grandes artérias (TGA) que perderam a chance da cirurgia no período neonatal ou naqueles já submetidos à correção no plano atrial (Senning ou Mustard) e ainda nos portadores de transposição corrigida das grandes artérias (TCGA), que evoluíram com disfunção do ventrículo direito (sistêmico). Nesses casos, a bandagem do TP poderá induzir a hipertrofia do ventrículo sub-pulmonar (ventrículo esquerdo) na TGA, habilitando-o para o manuseio da circulação sistêmica após a cirurgia de Jatene. Entretanto, durante o preparo do ventrículo esquerdo (VE), observa-se elevada morbimortalidade, provavelmente relacionada a uma sobrecarga aguda de pressão, não tolerada pelo ventrículo. Isto se deve à dificuldade em ajustar o diâmetro da bandagem do TP, realizada em condições não fisiológicas, com o paciente anestesiado e com o tórax aberto. O objetivo deste trabalho foi o de comparar a eficiência de dois protocolos experimentais de sobrecarga pressórica contínua e intermitente do ventrículo direito (VD) para induzir a hipertrofia rápida do ventrículo subpulmonar. Foram utilizados 21 cabritos jovens (30 a 60 dias de idade), divididos em três grupos: controle (n = 7, peso = 7,5 ± 1,9 kg), contínuo (n = 7, peso = 9,3 ± 1,4 kg, sobrecarga sistólica contínua do VD), intermitente (n = 7, peso = 8,1 ± 0,8 kg, 12 horas/dia de sobrecarga sistólica do VD). A sobrecarga sistólica foi obtida através de um manguito hidráulico de silicone implantado no tronco pulmonar. O dispositivo foi insuflado percutaneamente, através de um botão auto selante de silicone, com o objetivo de se atingir uma relação de pressões entre VD e VE de 70%. Avaliações ecocardiográficas e hemodinâmicas foram feitas diariamente. A sobrecarga sistólica do VD foi mantida por 96 horas no grupo contínuo e por quatro períodos de 12 horas, alternados com 12 horas de descanso, no grupo intermitente. Os animais foram então sacrificados para avaliação do conteúdo de água do miocárdio. O grupo intermitente mostrou um aumento significativo (p < 0,05) das massas musculares do VD (1,7 g/kg ± 0,5 g/kg) e do septo (1,4 g/kg ± 0,3 g/kg), quando comparados às massas musculares do grupo controle (VD: 0,9 g/kg ± 0,2 g/kg; septo: 1,0 g/kg ± 0,2 g/kg), enquanto o grupo contínuo apresentou aumento apenas da massa do VD (p < 0,05). Um aumento da espessura da parede livre do VD foi obtido em ambos os grupos (contínuo: de 3,3 ± 0,5 mm para 5,1 ± 0,9 mm e intermitente: de 2,4 ± 0,5 mm para 6,3 ± 1,4 mm, p < 0,05). Entretanto, foi observado um maior volume diastólico do VD ao longo do protocolo no grupo contínuo, quando comparado ao grupo intermitente (p = 0,01). A disfunção do VD durante o protocolo de sobrecarga sistólica foi mais freqüentemente observada no grupo contínuo, com tendência a menores valores de fração de ejeção do VD em relação ao grupo Intermitente. Em relação ao perímetro do VD, foi observado um menor valor no grupo intermitente no final do protocolo (96 horas de treinamento), quando comparado ao primeiro dia de treinamento (tempo zero) do grupo contínuo (p < 0,05). O ganho de massa atingido em ambos os grupos provavelmente foi decorrente de síntese protéica aumentada, pois não houve diferença significante no conteúdo de água do miocárdio do VD entre os grupos de estudo e o grupo controle. A bandagem ajustável do TP permitiu uma rápida hipertrofia do VD durante um curto período de sobrecarga sistólica, em ambos os grupos. Entretanto, a sobrecarga sistólica intermitente permitiu um processo hipertrófico mais abrangente do VD que no grupo submetido a sobrecarga sistólica de forma contínua, considerando a maior hipertrofia septal. Este estudo sugere que a preparação do ventrículo sub-pulmonar com a sobrecarga sistólica intermitente, como um programa de condicionamento físico, poderá proporcionar melhor resultado para a cirurgia de Jatene em dois estágios, não apenas para pacientes portadores de TGA, como também para aqueles com ventrículo sistêmico falido na TCGA e ainda após as operações de Senning ou Mustard. / Preparation of the subpulmonary ventricle with pulmonary trunk (PT) banding may be applied not only in patients with transposition of the great arteries (TGA) beyond the neonatal period, but also in those who present with systemic ventricular failure in corrected TGA or after failed atrial baffle operations. PT banding can induce subpulmonary ventricle hypertrophy that must be able to assume the increased work load and support the systemic circulation. However, subpulmonary ventricle training carries a high morbidity and mortality rates, probably related to acute pressure overload, not tolerated by the ventricle. Adjustment of PT banding under non-physiological conditions is hard to achieve. We sought to assess two different programs of systolic overload (continuous and intermittent) on the pulmonary ventricle (RV) of young goats with the aim of inducing rapid ventricular hypertrophy. Twenty one healthy 60-days-old goats were divided in three groups: control (n = 7, wt = 7.5±1.9 kg, no surgical procedure), continuous stimulation (n = 7, wt = 9.3±1.4 kg, continuous RV systolic overload), and intermittent stimulation (n = 7, wt = 8.1 ± 0.8 kg, 12 hours a day RV systolic overload). Pressure load was achieved by an adjustable PT banding device. The device was implanted around the PT and inflated percutaneously so that a 0.7 RV/LV pressure ratio was achieved. Echocardiographic and hemodynamic evaluations were performed every day. Systolic overload was maintained for 96 hours in the continuous group, while the intermittent group had four 12-hour periods of systolic overload, alternated with a resting period of 12 hours. The animals were then killed for water content evaluation. The inttermitent group achieved a significant increase (p<0,05) of RV mass (1,7 g/kg ± 0,5 g/kg) and septum (1,4 g/kg ± 0,3 g/kg), as compared to the ones from control group (RV: 0,9 g/kg ± 0,2 g/kg; septum: 1,0 g/kg ± 0,2 g/kg), while the continuous group showed only an RV mass increase (p < 0,05). A significant increase in the RV wall thickness was observed in both groups (continuous: from 3.3 ± 0.5 mm to 5.1 ± 0.9 mm and intermittent: from 2.4±0.5 mm to 6.3±1.4 mm, p < 0.05). However, a higher RV diastolic volume was observed in the continuous group, when compared to intermittent group (p = 0.01). RV dysfunction was more frequently observed in the continuous group, with a trend for a lower ejection fraction throughout the protocol as compared to the intermittent group. RV perimeter was smaller in intermittent group at the end of the protocol (96 hours training), when compared to the baseline continuous group (p < 0.05). RV mass acquisition was probably related to increased protein synthesis in both groups, since there was no significant difference in RV myocardial water content between the study groups and the control group. Adjustable PT banding has permitted rapid RV hypertrophy during a short period of time in both groups. Nevertheless, intermittent systolic overload has permitted a hypertrophic process more comprising than continuous overload. This study suggests that preparation of the pulmonary ventricle with intermittent systolic overload, similar to a fitness program, might provide better results for 2-stage arterial switch operation not only in patients with TGA beyond the neonatal period but also in those who present with systemic ventricular failure in corrected TGA or after failed atrial baffle operations.
207

Análise do processo de adaptação ventricular após bandagem do tronco pulmonar em animais adultos / Study of right ventricles adaptation process following pulmonary artery banding in adult animals

Miana, Leonardo Augusto 06 November 2009 (has links)
Pacientes portadores de transposição das grandes artérias submetidos previamente. Correção cirúrgica no plano atrial ou transposição corrigida das grandes artérias freqüentemente evoluem com disfunção do ventrículo direito morfológico. Para estes casos, tem sido proposta a correção anatômica, chamada cirurgia de Double Switch ou dupla inversão, invariavelmente realizada na adolescência ou na idade adulta. Com isso, grande parte destes pacientes necessita preparar o ventrículo esquerdo, através da bandagem do tronco pulmonar. Várias são as dificuldades no preparo do miocárdio adulto e resultados desapontadores são relatados nestes indivíduos. O objetivo deste trabalho foi promover e analisar o processo de adaptação do ventrículo direito em modelo animal adulto, comparando o método de bandagem fixa, utilizado tradicionalmente na prática clínica, com um novo método de bandagem intermitente, por um período de quatro semanas. Foram utilizadas 18 cabras adultas, divididas Em três grupos: Chama (n = 6, peso = 26,42. 2,63 Kg, bandagem frouxa, sem sobrecarga sistólica), Fixo (n = 6, peso = 26,33 . 2,32 kg, bandagem convencional com sobrecarga sistólica contínua do ventrículo direito), Intermitente (n = 6, peso = 25,17. 2,48 kg, bandagem com dispositivo ajustável e 12 horas diárias de sobrecarga sistólica do ventrículo direito). No grupo fixo, os animais foram submetidos bandagem do tronco pulmonar com fita umbilical, tentando alcançar uma relação pressórica entre ventrículo direito e aorta de 0,7 no momento da cirurgia. Nos animais do grupo Intermitente, a sobrecarga sistólica foi promovida por um dispositivo ajustável calibrado percutaneamente. A mesma relação pressórica foi almejada diariamente através da insuflação do dispositivo por 12 horas, alternada com 12 horas de desinsuflação do dispositivo. Aferições hemodinâmicas foram feitas três vezes por semana no grupo Intermitente e duas vezes por semana nos grupos Fixo e Sham. Exames ecocardiográficos foram realizados semanalmente em todos os animais. Após quatro semanas, os animais foram submetidos à eutanásia para avaliação das massas musculares, do conteúdo de água do miocárdio e estudo histológico. A área de sobrecarga pressórica, medida através do gradiente entre o ventrículo direito e o tronco pulmonar ao longo do estudo, foi maior no grupo Fixo (p<0,001). O estudo ecocardiográfico demonstrou aumento de até 37,2% na espessura da parede livre do ventrículo direito ao longo do protocolo no grupo Intermitente, o que foi significativamente maior que a variação na espessura dos grupos Sham e Fixo (p<0,05). Em relação ao peso do ventrículo direito normalizado para o peso do animal, os grupos Intermitente (1,24 g/Kg ± 0,16 g/Kg) e Fixo (1,08 g/Kg ± 0,17 g/Kg) apresentaram aumento da massa de 55,7% e 36,7% (p<0,05), respectivamente, em comparação ao grupo Sham (0,79 g/Kg ± 0,15 g/Kg). O conteúdo de água não variou entre os grupos estudados. As medidas dos diâmetros dos cardiomiócitos do ventrículo direito do grupo Intermitente apresentaram um incremento de 19,2% (p=0,036), em relação às medidas do grupo Sham. Paralelamente, houve aumento de 22,8% no diâmetro dos núcleos dos cardiomiócitos no ventrículo direito do grupo Intermitente, em comparação com o grupo Sham (p=0,049). Os animais do grupo Fixo exibiram um incremento de 98,0% na porcentagem de área de colágeno no VD, quando comparado ao grupo Sham (p<0,01), e de 69,2% em relação ao grupo Intermitente (p<0,05). A análise de proliferação celular não evidenciou diferença entre os grupos. Este estudo ratifica a necessidade de se buscar uma melhor forma de preparo dos miocárdios maduros, uma vez que o método tradicional de bandagem do tronco pulmonar promoveu maior área de sobrecarga pressórica, sem, no entanto, gerar hipertrofia significativa, além de apresentar maior teor de colágeno no miocárdio. Por outro lado, o método alternativo de preparo intermitente foi capaz de promover hipertrofia miocárdica com menor sobrecarga sistólica do ventrículo direito. Com isso, supõe-se que, com vistas à cirurgia de Double Switch, a bandagem intermitente parece ser uma alternativa promissora para promover o preparo ventricular de forma mais eficiente e menos lesiva que o método de bandagem fixa, nos pacientes adolescentes e adultos portadores de transposiço das grandes artérias ou de transposição corrigida das grandes artérias com falência ventricular direita / One of the late complications of patients with simple or congenitally corrected transposition of the great arteries includes right (systemic) ventricular failure. The policy of anatomic repair (double switch operation) has often been proposed for adolescents and adults. However, a period of reconditioning the left ventricle through pulmonary artery banding is often required. Although it appears to be capable of providing adequate left ventricular training when done at an early age, it is not always suitable for mature myocardium, with disappointing results in older patients. This study sought to assess two different methods of promoting right ventricles hypertrophy in adult animals for a four-week period, by means of fixed and intermittent adjustable pulmonary artery banding system. Eighteen healthy adult goats were distributed into three groups: Sham (n = 6, weight = 26.42 kg Ž 2.63 kg, loose pulmonary artery banding, no systolic pressure overload), Fixed (n = 6, weight = 26.33 kg Ž 2.32 kg, continuous systolic overload with fixed pulmonary artery band) and Intermittent (n = 6, weight = 25.17 kg Ž 2.48 kg, daily 12-hour systolic overload with adjustable pulmonary artery band). Sham group animals received a loose pulmonary band, while in the Fixed group, an umbilical tape was used to band the pulmonary trunk, adjusted during the implantation to achieve a 0.7 right ventricle / aorta pressure ratio. In the Intermittent group, an adjustable pulmonary artery banding device was implanted on the pulmonary trunk and adjusted according to the volume injected percutaneously. The banding system was inflated daily until the 0.7 pressure ratio was achieved. Systolic overload was maintained for 12 hours, alternated with a 12-hour resting period. All animals were submitted to echocardiographic studies on a weekly basis, while hemodynamic evaluations were performed three times a week in the Intermittent group and twice a week in the Fixed and Sham groups. After four weeks, all animals were humanely killed for ventricular masses and water content assessment and histological evaluation. Intermittent group was submitted to a significant smaller systolic overload area, measured by right ventricle / pulmonary artery pressure gradient over time, as compared to Fixed group (p<0.001), and both of them showed a greater systolic overload area when compared to the Sham group (p<0.001). Echocardiographic findings revealed an increase in the right ventricle wall thickness, up to 37.2%, in the Intermittent group during the protocol, and this increase was significantly greater than in Sham and Fixed groups (p<0.05). Regarding the right ventricular mass, both Intermittent (1.24 g/kg ± 0.16 g/kg) and Fixed (1.08 g/Kg ± 0.17 g/kg) groups showed a 55.7% and 36.7% increase respectively (p<0.05) compared to Sham group (0.79 g/Kg ± 0.15 g/kg). No differences in left ventricular and interventricular septum masses were observed among the three groups. Likewise, water content was not significantly different between groups. Intermittent group showed a 19.2% increase in right ventricle myocardial fiber diameter and a 22.8% increase in myocardial fiber nuclei diameter, compared to Sham group (p<0.05). Fixed group showed a 98% increase in right ventricle´s collagen percentage area, when compared to Sham group (p<0.01), and a 69.2% increase compared to Intermittent group (p<0.05). There was no significant cellular proliferation in any groups. This study shows the urgency in seeking for an alternative method of promoting hypertrophy in mature myocardium, since traditional pulmonary artery banding caused increase in collagen area without significant hypertrophy and experimental adjustable intermittent pulmonary artery banding promoted hypertrophy with less systolic overload without increasing collagen area. In conclusion, it suggests that a more effective and less harmful hypertrophy can be achieved with intermittent pulmonary artery banding, as compared to the fixed method, to prepare the left ventricle for the double switch operation in adolescent and adult patients with simple and congenitally corrected transposition of great arteries with failed systemic right ventricle
208

Análise da função ventricular direita em dois protocolos de treinamento com bandagem ajustável do tronco pulmonar / Assessment of right ventricular function in two training protocols with adjustable pulmonary banding

Favaro, Gustavo Antonio Guimarães 13 December 2011 (has links)
A transposição das grandes artérias (TGA) com septo interventricular (SIV) íntegro tem como correção ideal a cirurgia de Jatene no período neonatal. Caso o paciente não seja operado nesse período, o ventrículo esquerdo pode-se tornar despreparado para sustentar a circulação sistêmica. O treinamento do ventrículo subpulmonar, através da bandagem do tronco pulmonar (TP), é uma opção terapêutica nestes casos, preparando para posterior correção definitiva. A hipótese da realização de uma bandagem pulmonar com estresse sistólico ajustável para treinar o ventrículo subpulmonar minimizaria as inadequações da bandagem convencional e aperfeiçoaria o preparo destes ventrículos. Estudos prévios desta linha de pesquisa não evidenciaram diferenças funcionais, na condição de repouso, entre os dois protocolos de preparo ventricular com sobrecarga contínua e intermitente. O objetivo do presente estudo foi o de analisar a função ventricular durante o processo de hipertrofia ventricular aguda e as repercussões na função sistólica e diastólica do ventrículo direito (VD), em condições de repouso e estresse farmacológico, em animais jovens, submetidos a dois protocolos de sobrecarga pressórica ajustável, sendo um de forma contínua e outro de forma intermitente. Foram utilizados 19 cabritos hígidos, com idade aproximada de 60 dias e pesos comparáveis, divididos em três grupos: Sham (n = 7, cirurgia controle), Contínuo (n = 6, sobrecarga sistólica contínua do VD), Intermitente (n = 6, 12 horas/dia de sobrecarga sistólica do VD). A sobrecarga sistólica do VD foi mantida por 96 horas no grupo contínuo e por quatro períodos de 12 horas, alternados com 12 horas de descanso, no grupo intermitente. Os animais do grupo Sham foram submetidos ao implante do dispositivo de bandagem, o qual foi mantido desinsuflado. Avaliações ecocardiográficas e hemodinâmicas foram feitas diariamente. A função cardíaca em repouso e sob o estresse farmacológico induzido por dobutamina foi analisada em dois momentos: basal e após 96 horas do início do protocolo de sobrecarga. Após 96 horas de estudo, os animais foram mortos para avaliação dos parâmetros morfológicos. Ao final do protocolo, foi observada uma diferença significativa da espessura do VD no grupo Intermitente (+64,8% ± 23,37%), quando comparado ao grupo Contínuo (+43,9% ± 19,26%; p = 0,001) e de ambos os grupos de estudo quando comparados ao grupo Sham (p < 0,001). Os grupos de estudo apresentaram dilatação do VD no início do protocolo (tempo zero, p < 0,001), quando comparados ao grupo Sham. Entretanto, apenas o grupo Contínuo manteve a dilatação significativa do VD ao longo do protocolo (p < 0,006). Foi observada piora da fração de ejeção nos dois grupos de estudo, logo após o início da sobrecarga sistólica do VD (momento zero e 24 horas; p < 0,002), recuperando-se posteriormente no final do protocolo. No entanto, o grupo Contínuo manteve a fração de ejeção rebaixada por mais tempo que o grupo Intermitente (72 horas versus 48 horas respectivamente, p < 0,001), apesar de estar dentro dos limites da normalidade. Na situação de repouso, o desempenho miocárdico do VD no grupo Contínuo foi significativamente pior que o do grupo Sham, após 72 horas e 96 horas de treinamento ventricular (p < 0,039). Sob estresse farmacológico, o grupo Contínuo apresentou piora dos índices não apenas em relação ao grupo Sham, como também em relação ao grupo Intermitente (p < 0,01). À análise morfológica, ambos os grupos de estudo apresentaram magnitude semelhante de aumentos das massas do VD, apesar do menor tempo de sobrecarga pressórica no grupo intermitente. Apesar de ambos os protocolos de sobrecarga sistólica do VD promoverem ganho de massa ventricular de magnitude semelhante, a sobrecarga sistólica intermitente foi superior no sentido de preservar o desempenho miocárdico do VD em cabritos / The ideal surgical treatment of transposition of the great arteries is the Jatene operation during the neonatal period. If the neonate remains untreated for several reasons, the left ventricle may become unprepared to sustain systemic circulation. The preparation of the subpulmonary ventricle by pulmonary trunk (PT) banding is an option for the 2-stage Jatene operation. The hypothesis of PT banding with an adjustable device to retrain the subpulmonary ventricle could minimize the inadequacies of conventional banding and improve the preparation of those ventricles. Previous studies have shown no differences on systolic function between two different protocols of subpulmonary ventricle retraining, during resting condition. The aim of the present study was to assess ventricular function during two protocols of PT banding and the impact on systolic and diastolic function of the right ventricle (RV), at rest and under pharmacological stress. Nineteen healthy young goats, aged approximately 60 days and with comparable weights, were divided into three groups: Sham (n = 7, surgery control with no systolic overload), Continuous (n = 6, 96 hours of continuous RV systolic overload), Intermittent (n = 6, four 12-hour periods of systolic overload paired with a 12-hour resting period). before and after systolic overload every day postoperatively. Cardiac function at rest and under pharmacological stress induced by dobutamine was assessed on two occasions: baseline and after 96 hours. After 96-hour study period, all the animals were euthanized for morphologic assessment. There was a significant increase in RV free wall thickness of the Intermittent Group (+64.8% ± 23.37%) at the end of the protocol, when compared to Continuous Group (+43.9% ± 19.26%, p = 0.015). Both study groups presented a dilated RV after starting systolic overload (time zero, p < 0.001), as compared to Sham group. However, only Continuous group remained with significant RV dilation throughout the protocol (p < 0.006). Worsening of RV ejection fraction was observed in the two study groups after beginning systolic overload as well (time zero and 24 hours, p < 0.002), with recovery to normal levels at the end of the protocol. Nevertheless, RV ejection fraction of the Continuous Group remained lower than Intermittent Group for a longer period (72 hours versus 48 hours, p < 0.001). At rest, RV myocardial performance of the Continuous Group was significantly worse than Sham Group, after 72 hours and 96 hours of protocol (p < 0,039). Under dobutamine stress, Continuous Group presented worsening myocardial performance indexes, as compared to both Intermittent and Sham Group (p < 0.01). Regarding morphological analysis, both study groups presented an increased RV mass of similar magnitude, despite less exposure of Intermittent Group to pressure overload. Although both protocols of RV systolic overload had induced similar RV mass gain, intermittent systolic overload was more efficient in preserving RV myocardial performance in goats
209

Avaliação experimental do metabolismo energético em dois protocolos de sobrecarga sistólica do ventrículo direito / Experimental evaluation of energy metabolism in two right ventricle systolic overload protocols

Fernando Antibas Atik 16 March 2012 (has links)
Objetivo: Alterações do metabolismo energético tem sido identificadas em processos de hipertrofia miocárdica, sendo algumas consideradas benéficas, porém outras estão associadas a insuficiência cardíaca. O objetivo deste trabalho foi comparar a atividade de três enzimas do metabolismo energético em dois protocolos de sobrecarga sistólica do ventrículo direito (VD) num modelo experimental em cabritos. Métodos: 27 cabritos jovens foram divididos em três grupos: Sham (sem sobrecarga), Contínuo (sobrecarga sistólica constante) e Intermitente (4 períodos de 12 horas de sobrecarga sistólica, intercalados com 12 horas de descanso). Durante as 96 horas do protocolo, a sobrecarga sistólica foi ajustada a fim de atingir relação de pressão entre a aorta e o VD de 0,7. Medidas ecocardiográficas e hemodinâmicas foram realizadas antes e após o período de sobrecarga diariamente até o término do protoloco. Após o término do mesmo, os animais foram sacrificados a fim de obter dados morfológicos e a atividade máxima das enzimas Glicose 6 Fosfato Desidrogenase (G6PD), Hexoquinase (HK) e Lactato Desidrogenase (LDH). Resultados: Houve aumento de 92,1% e 46,5% nas massas do VD e septal no grupo Intermitente, respectivamente, quando comparado ao grupo Sham, enquanto que no grupo Contínuo houve incremento de 37,2% somente na massa septal. O VD e Septo dos grupos submetidos à sobrecarga sistólica contínua e intermitente do VD apresentaram um aumento discreto, porém significativo, do conteúdo de água (VD, p=0,0014; Septo, p=0,0004) em relação ao grupo Sham. Ao final do protocolo, foi observado um aumento significativo de 103,8% da espessura do VD no grupo Intermitente, comparado a um aumento de 38,4% do grupo Contínuo. Houve também dilatação ventricular significativa no grupo Contínuo ao longo do protocolo, quando comparado aos outros grupos (p<0,001). Piores índices de desempenho miocárdico ocorreram no grupo Contínuo no momentos 72 e 96 horas, quando comparados ao grupos Sham (P<0,039) e Intermitente (P<0,001). A razão da atividade máxima da G6PD do VD pelo VE revelou um aumento de 130,1% no grupo contínuo (p= 0,012) e de 39,8% no grupo Intermitente (p=0,764), quando comparados ao grupo Sham. O processo de hipertrofia aguda do VD não afetou a atividade enzimática da HK e LDH nos grupos estudados. Conclusões: Apesar de haver uma sobrecarga sistólica proporcionalmente menor no VD do grupo intermitente, a bandagem intermitente do TP promoveu maior hipertrofia do VD. A maior atividade da G6PD observada no grupo contínuo sugere maior produção de radicais livres via NADPH oxidase, haja vista que o ciclo das pentoses Fosfato incrementa a disponibilidade de NADPH citoplasmático, ocasionados pela maior demanda de um estímulo de sobrecarga miocárdica constante, um importante mecanismo de insuficiência cardíaca. Este estudo sugere que a preparação do ventrículo sub-pulmonar com a sobrecarga sistólica intermitente poderá proporcionar melhor resultado para a cirurgia de Jatene em dois estágios que a sobrecarga contínua / Objective: Altered energy metabolism has been identified in myocardial hypertrophy. Some processes are considered beneficial, whereas others are linked to heart failure. The purpose of this study was to compare the activity of three different energy metabolism enzymes in two different protocols of right ventricle (RV) systolic overload in young goats. Methods: 27 young goats were separated into three groups: Sham (no overload), Continuous (continuous systolic overload) and Intermittent (4 periods of 12-hour systolic overload, alternated with a 12-hour resting period). During a 96-hour protocol, systolic overload was adjusted to achieve a 0.7 RV / aortic pressure ratio. Echocardiographic and hemodynamic evaluations were performed before and after systolic overload every day postoperatively. After the study period, the animals were humanely killed for morphological and Glucose-6-phosphate dehydrogenase (G6PD), hexoquinase (HK) and lactate dehydrogenase (LDH) activity assessment. Results: There was a 92.1% and 46.5% increase in RV and septal masses of Intermittent group, respectively, as compared to Sham group, while Continuous systolic overload resulted in 37.2% increase of only septal mass. There was a small, but significant increase in water content in RV and septum of Intermittent and Continuous groups, as compared to Sham group (RV, p=0.0014; Septum, p=0.0004). At the end of protocol, it was observed a greater increase in RV thickness (103.8%) in Intermittent group, as compared to Continous group (38.4%). There was also a significant right ventricle dilatation in Continuos group along the protocol, as compared to the other groups (p<0.001). A worsening RV myocardial performance index occurred in the continuous group at 72 hours and 96 hours, compared with the sham (P<0.039) and intermittent groups (P<0.001). Compared to Sham, RV to LV G6PD activity ratio was elevated by 130.1% in Continuous group (p= 0,012) and by 39.8% in Intermittent group (p=0.764). The acute hypertrophic process in the RV did not altered the HK and LDH enzymatic activity among study groups. Conclusions: Despite of a proportional lesser exposure to systolic overload, intermittent pulmonary trunk banding promoted greater RV hypertrophy. This study indicates that continuous systolic overload for ventricle retraining causes upregulation and hyperactivity of myocardial G6PD. Since pentose phosphate pathway enhances cytosolic NADPH availability, this altered energy substrate metabolism can elevate levels of free radicals by NADPH oxidase, an important mechanism in the pathophysiology of heart failure. It suggests that Intermittent systolic overload may provide better results for 2-stage Jatene operation as compared to continuous protocol
210

Análise da função ventricular direita em dois protocolos de treinamento com bandagem ajustável do tronco pulmonar / Assessment of right ventricular function in two training protocols with adjustable pulmonary banding

Gustavo Antonio Guimarães Favaro 13 December 2011 (has links)
A transposição das grandes artérias (TGA) com septo interventricular (SIV) íntegro tem como correção ideal a cirurgia de Jatene no período neonatal. Caso o paciente não seja operado nesse período, o ventrículo esquerdo pode-se tornar despreparado para sustentar a circulação sistêmica. O treinamento do ventrículo subpulmonar, através da bandagem do tronco pulmonar (TP), é uma opção terapêutica nestes casos, preparando para posterior correção definitiva. A hipótese da realização de uma bandagem pulmonar com estresse sistólico ajustável para treinar o ventrículo subpulmonar minimizaria as inadequações da bandagem convencional e aperfeiçoaria o preparo destes ventrículos. Estudos prévios desta linha de pesquisa não evidenciaram diferenças funcionais, na condição de repouso, entre os dois protocolos de preparo ventricular com sobrecarga contínua e intermitente. O objetivo do presente estudo foi o de analisar a função ventricular durante o processo de hipertrofia ventricular aguda e as repercussões na função sistólica e diastólica do ventrículo direito (VD), em condições de repouso e estresse farmacológico, em animais jovens, submetidos a dois protocolos de sobrecarga pressórica ajustável, sendo um de forma contínua e outro de forma intermitente. Foram utilizados 19 cabritos hígidos, com idade aproximada de 60 dias e pesos comparáveis, divididos em três grupos: Sham (n = 7, cirurgia controle), Contínuo (n = 6, sobrecarga sistólica contínua do VD), Intermitente (n = 6, 12 horas/dia de sobrecarga sistólica do VD). A sobrecarga sistólica do VD foi mantida por 96 horas no grupo contínuo e por quatro períodos de 12 horas, alternados com 12 horas de descanso, no grupo intermitente. Os animais do grupo Sham foram submetidos ao implante do dispositivo de bandagem, o qual foi mantido desinsuflado. Avaliações ecocardiográficas e hemodinâmicas foram feitas diariamente. A função cardíaca em repouso e sob o estresse farmacológico induzido por dobutamina foi analisada em dois momentos: basal e após 96 horas do início do protocolo de sobrecarga. Após 96 horas de estudo, os animais foram mortos para avaliação dos parâmetros morfológicos. Ao final do protocolo, foi observada uma diferença significativa da espessura do VD no grupo Intermitente (+64,8% ± 23,37%), quando comparado ao grupo Contínuo (+43,9% ± 19,26%; p = 0,001) e de ambos os grupos de estudo quando comparados ao grupo Sham (p < 0,001). Os grupos de estudo apresentaram dilatação do VD no início do protocolo (tempo zero, p < 0,001), quando comparados ao grupo Sham. Entretanto, apenas o grupo Contínuo manteve a dilatação significativa do VD ao longo do protocolo (p < 0,006). Foi observada piora da fração de ejeção nos dois grupos de estudo, logo após o início da sobrecarga sistólica do VD (momento zero e 24 horas; p < 0,002), recuperando-se posteriormente no final do protocolo. No entanto, o grupo Contínuo manteve a fração de ejeção rebaixada por mais tempo que o grupo Intermitente (72 horas versus 48 horas respectivamente, p < 0,001), apesar de estar dentro dos limites da normalidade. Na situação de repouso, o desempenho miocárdico do VD no grupo Contínuo foi significativamente pior que o do grupo Sham, após 72 horas e 96 horas de treinamento ventricular (p < 0,039). Sob estresse farmacológico, o grupo Contínuo apresentou piora dos índices não apenas em relação ao grupo Sham, como também em relação ao grupo Intermitente (p < 0,01). À análise morfológica, ambos os grupos de estudo apresentaram magnitude semelhante de aumentos das massas do VD, apesar do menor tempo de sobrecarga pressórica no grupo intermitente. Apesar de ambos os protocolos de sobrecarga sistólica do VD promoverem ganho de massa ventricular de magnitude semelhante, a sobrecarga sistólica intermitente foi superior no sentido de preservar o desempenho miocárdico do VD em cabritos / The ideal surgical treatment of transposition of the great arteries is the Jatene operation during the neonatal period. If the neonate remains untreated for several reasons, the left ventricle may become unprepared to sustain systemic circulation. The preparation of the subpulmonary ventricle by pulmonary trunk (PT) banding is an option for the 2-stage Jatene operation. The hypothesis of PT banding with an adjustable device to retrain the subpulmonary ventricle could minimize the inadequacies of conventional banding and improve the preparation of those ventricles. Previous studies have shown no differences on systolic function between two different protocols of subpulmonary ventricle retraining, during resting condition. The aim of the present study was to assess ventricular function during two protocols of PT banding and the impact on systolic and diastolic function of the right ventricle (RV), at rest and under pharmacological stress. Nineteen healthy young goats, aged approximately 60 days and with comparable weights, were divided into three groups: Sham (n = 7, surgery control with no systolic overload), Continuous (n = 6, 96 hours of continuous RV systolic overload), Intermittent (n = 6, four 12-hour periods of systolic overload paired with a 12-hour resting period). before and after systolic overload every day postoperatively. Cardiac function at rest and under pharmacological stress induced by dobutamine was assessed on two occasions: baseline and after 96 hours. After 96-hour study period, all the animals were euthanized for morphologic assessment. There was a significant increase in RV free wall thickness of the Intermittent Group (+64.8% ± 23.37%) at the end of the protocol, when compared to Continuous Group (+43.9% ± 19.26%, p = 0.015). Both study groups presented a dilated RV after starting systolic overload (time zero, p < 0.001), as compared to Sham group. However, only Continuous group remained with significant RV dilation throughout the protocol (p < 0.006). Worsening of RV ejection fraction was observed in the two study groups after beginning systolic overload as well (time zero and 24 hours, p < 0.002), with recovery to normal levels at the end of the protocol. Nevertheless, RV ejection fraction of the Continuous Group remained lower than Intermittent Group for a longer period (72 hours versus 48 hours, p < 0.001). At rest, RV myocardial performance of the Continuous Group was significantly worse than Sham Group, after 72 hours and 96 hours of protocol (p < 0,039). Under dobutamine stress, Continuous Group presented worsening myocardial performance indexes, as compared to both Intermittent and Sham Group (p < 0.01). Regarding morphological analysis, both study groups presented an increased RV mass of similar magnitude, despite less exposure of Intermittent Group to pressure overload. Although both protocols of RV systolic overload had induced similar RV mass gain, intermittent systolic overload was more efficient in preserving RV myocardial performance in goats

Page generated in 0.0498 seconds