• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • 102
  • 69
  • 37
  • 25
  • 13
  • 10
  • 8
  • 8
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 476
  • 476
  • 76
  • 54
  • 49
  • 48
  • 48
  • 47
  • 46
  • 46
  • 46
  • 42
  • 40
  • 38
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Cesium Voltilization in LiF-BeF2: Predicting Release in the Event of FHR Fuel Failure

Williams, Johnny Hedrick 22 June 2023 (has links) (PDF)
This work demonstrates how ICP-MS can be employed to evaluate cesium volatilization from LiF-BeF2 (Flibe) salt with ab initio molecular dynamics studies used as corroborating data to better understand cesium behavior. Using mixtures of Flibe with 2 mol% CsF, it was found that cesium was stable within the salt melt at temperatures between 500-650°C over a time span of 8 hours. At 800°C, cesium vaporized from the salt at a rate of 0.83% / hr with a mass flux of 0.0023 g Cs / cm2hr. The atomistic modeling results show poor solvation of Cs at 500°C and 800°C, with stability preferred at 650°C. Specialized equipment and procedures were needed to enable this work, especially those required for safe handling of beryllium containing salts. The methods, custom equipment, and important considerations for working with high-temperature fluoride salts are detailed in this thesis.
302

Analysis of Lipids in Kidney Tissue Using High Resolution MALDI Mass Spectrometry Imaging

Aboulmagd Khodier, Sarah 25 September 2018 (has links)
Massenspektrometrisches Imaging (MSI) ist unverzichtbar für die Untersuchung der räumlichen Verteilung von Molekülen in einer Vielzahl von biologischen Proben. Seit seiner Einführung hat sich MALDI zu einer dominierenden Bildgebungsmethode entwickelt, die sich als nützlich erwiesen hat, um die Komplexität von Lipidstrukturen in biologischen Geweben zu bestimmen. Einerseits ist die Rolle von Cisplatin bei der Behandlung von menschlichen malignen Erkrankungen gut etabliert, jedoch ist Nephrotoxizität eine limitierende Nebenwirkung, die Veränderungen des renalen Lipidprofils beinhaltet. Dies führte zu der Motivation, die Lipidzusammensetzung des Nierengewebes in mit Cisplatin behandelten Ratten zu untersuchen, um die involvierten Lipid-Signalwege aufzuklären. Es wurde eine Methode zur Kartierung der Lipidzusammensetzung in Nierenschnitten unter Verwendung von MALDI MSI entwickelt. Die Verteilung von Nierenlipiden in Cisplatin-behandelten Proben zeigte deutliche Unterschiede in Bezug auf die Kontrollgruppen. Darüber hinaus wurde die Beurteilung der Ionenbilder von Lipiden in Cisplatin-behandelten Nieren meist als qualitative Aspekte betrachtet. Relative quantitative Vergleiche wurden durch den variablen Einfluss von experimentellen und instrumentellen Bedingungen begrenzt. Daher bestand die Notwendigkeit, ein Normalisierungsverfahren zu entwickeln, das einen Vergleich der Lipidintensität verschiedener Proben ermöglicht. Das Verfahren verwendete einen Tintenstrahldrucker, um eine Mischung der MALDI-Matrix und der internen internen Lipid-Metall-Standards aufzubringen. Unter Verwendung von ICP-MS erlaubte der interne Metallstandard, die Konsistenz der Matrix und der internen Standards zu bestätigen. Die Anwendung der Methode zur Normalisierung von Ionenintensitäten von Nierenlipiden zeigte eine ausgezeichnete Bildkorrektur und ermöglichte einen relativen quantitativen Vergleich von Lipidbildern in Cisplatin-behandelten Proben. / Mass spectrometry imaging is indispensable for studying the spatial distribution of molecules within a diverse range of biological samples. Since its introduction, MALDI has become a dominant imaging method, which proved useful to sort out the complexity of lipid structures in biological tissues. The role of cisplatin in the treatment of human malignancies is well-established. However, nephrotoxicity is a limiting side effect that involves an acute injury of the proximal tubule and alterations in the renal lipid profile. This evolved the motivation to study the spatial distribution of lipids in the kidney tissue of cisplatin-treated rats to shed light on the lipid signaling pathways involved. A method for mapping of lipid distributions in kidney sections using MALDI-LTQ-Orbitrap was developed, utilizing the high performance of orbitrap detection. The distribution of kidney lipids in cisplatin-treated samples revealed clear differences with respect to control group, which could be correlated to the proximal tubule injury. The findings highlight the usefulness of MALDI MSI as complementary tool for clinical diagnostics. Furthermore, assessment of the ion images of lipids in cisplatin-treated kidney mostly considered qualitative aspects. Relative quantitative comparisons were limited by the variable influence of experimental and instrumental conditions. Hence, the necessity developed to establish a normalization method allowing comparison of lipid intensity in MALDI imaging measurements of different samples. The method employed an inkjet printer to apply a mixture of the MALDI matrix and dual lipid-metal internal standards. Using ICP-MS, the metal internal standard allowed to confirm the consistency of the matrix and internal standards application. Applying the method to normalize ion intensities of kidney lipids demonstrated excellent image correction and successfully enabled relative quantitative comparison of lipid images in control and cisplatin-treated samples.
303

Charakterisierung eines pharmazeutischen Antikörpers und geeigneter Aufreinigungsmethoden

Winkler, Rajko 02 November 2015 (has links)
In dieser Arbeit konnte ein humaner IgG1-Antikörper mittels verschiedener massenspektrometrischer Methoden erfolgreich untersucht und charakterisiert werden. Neben der Bestimmung der molekularen Massen des betrachteten Anti-Interleukin-8-Antikörpers und dessen Fragmenten konnte auch die Bildung von Oligomeren untersucht werden. Es wurden verschiedene Oligomere, bis hin zum Pentamer, massenspektrometrisch gemessen und es konnten auch Erkenntnisse gewonnen werden, dass Konzentrationseffekte maßgeblich zur Oligomerbildung bei diesem Antikörper beitragen. Die Antikörperglykosylierung, eine sehr prominente und hoch diverse Modifikation, wurde bei diesem Antikörper ebenfalls gefunden und neben dem intakten Antikörper auch in dessen Fragmenten und im Dimer gemessen. Neben dieser natürlichen Modifikation wurden auch Derivatisierungen des Antikörpers analysiert, dabei wurden unterschiedliche Metallmarkierungen analysiert. Es konnten verschiedene Markierungsgrade bestimmt werden, auch wenn diese nebeneinander als Mischung vorlagen. Der Nachweis, dass der Antikörper auch weiterhin intakt und bindungsfähig ist, konnte erbracht werden. Die Bildung von Komplexen des Antikörpers mit verschiedenen Proteinen konnte ebenfalls mittels Massenspektrometrie gezeigt werden. Weiterhin konnte gezeigt werden, dass es möglich war, eine Quantifizierungsstrategie für Antikörper zu entwickeln. Mit dieser können absolute Quantifizierungen durchgeführt werden, während diese gleichzeitig unabhängig von Art und Struktur des einzusetzenden Standards sind. Damit ist es möglich, die Probleme des Bradford-Assays zu umgehen. Des Weiteren sind nur minimale Kenntnisse über den zu analysierenden Antikörper notwendig, sodass dieses Verfahren auch hervorragend auf bisher nicht charakterisierte Antikörper angewendet werden kann. / The aim of this work is the characterization of an antibody. The used human IgG1-antibody was successfully investigated with various mass spectrometric methods. In addition to the determination of the molecular masses of the analyzed Anti-Interleukin-8 antibody itself and its fragments the formation of oligomers was examined. Different oligomers up to pentamers could be mass spectromatrically measured. Resulting from this, it was possible to find that concentration effects are the main factors for the oligomer formation of this particular antibody. The glycosylation of antibodies, a prominent and high diverse modification, was also found in this antibody and was measured in the intact molecule, in its fragments and also the dimer. Next to this native modification, also a derivatization of the antibody was investigated. Different metal containing modifications were analyzed. Thereby it was possible to determine various tagging degrees, even in a mixture of these metal containing modifications. The important question, whether the tagged antibody is still active and capable for binding, can be answered positively. Furthermore the formation of antibody-protein complexes could be shown via mass spectrometry. It was also successful to develop a quantification strategy for this antibody. With this an absolute quantification was possible, which was independent from the type and the structure of the used standard. With this method it is possible to overcome the problems of the Bradford assay. In addition to this only very little information about the antibody is needed for the quantification, which allows to use this method for non characterized antibodies.
304

Elementspurenbestimmung in Solarsilicium

Balski, Matthias Michael 17 June 2014 (has links)
Verunreinigungen von Fremdelementen können den Wirkungsgrad von Solarzellen schon im Spurenbereich beeinträchtigen. Die Kenntnis der Verunreinigungen in Si ist entscheidend für die Produkt- und Produktionskontrolle neuer Solarzellenmaterialien. In dieser Arbeit wurden Analysenmethoden mit unterschiedlichen Messverfahren unter besonderer Berücksichtigung der Ansprüche der Solarindustrie entwickelt, verbessert, charakterisiert und verglichen. Mit der Sektorfeld-Massenspektrometrie (SFMS) mit induktiv gekoppeltem Plasma (ICP) nach Matrixabtrennung konnten 22 Elemente mit Bestimmungsgrenzen bis zu 120 pg g−1, quantifiziert werden. Das neue Verfahren erlaubte die Bestimmung aller Elemente in einem Analysengang ohne Analytverlust. Dabei wurde ein bisher in der Literatur nicht beschriebener Mechanismus aufgeklärt, welcher die Retention von Bor im Matrixverdampfungsschritt ohne Zusatz von Komplexbildnern erlaubt. Mit der Glimmentladungs-(GD )MS wurden 32 Elemente bis in den sub ng g−1-Bereich bestimmt. Es gelang, relative Empfindlichkeitsfaktoren zur Quantifizierung von B, P, As, Ga, Ge und Fe zu errechnen. Methoden basierend auf der elektrothermischen Verdampfung (ETV), gekoppelt an ICP-MS und ICP-Emissionsspektroskopie (OES) sowie Gleichstrombogen-OES wurden zur Charakterisierung von metallurgischem Si-Pulver mit Gehalten im µg g−1-Bereich verwendet. Die Totalreflexion-Röntgenfluoreszenz wurde als Volumenmessmethode für die Si-Analytik eingesetzt. Komplettiert wird das Methodenspektrum durch Oberflächenanalytik von Wafern mittels Laserablation-(LA)-ICP-MS. Es wurden erstmalig für Silicium Konzepte zur quantitativen Bestimmung der Verunreinigungen auf Si-Wafern über eine Kalibrierung der LA mit eingetrockneten flüssigen Standards erarbeitet und gezeigt, dass sich das Verfahren zum Nachweis typischer metallischer Ausscheidungen eignet. Die Neutronenaktivierungsanalyse wurde als anerkannte Referenzmethode der Halbleiterindustrie zur Validierung der Methoden eingesetzt. / Element impurities can affect the efficiency of solar cells already on the trace level. The knowledge of the impurities in Si is thus crucial for the product and production control of new solar cell materials. In this work, analysis methods based on different measurement principles have been developed, improved, characterized and compared with special consideration of the requirements of the solar industry. Sector field mass spectrometry (SFMS) with inductively coupled plasma (ICP) subsequent to matrix separation has been used to determine 22 elements with limits of determination down to 120 pg g−1 on sample basis. The new, optimized procedure allowed the determination of all analytes in one sweep without analyte loss during the evaporation step. A so-far unexplained mechanism for the retention of boron without use of additional complexing agents was elucidated. Glow discharge (GD)MS was used to measure 32 elements down to the sub-ng g−1 range. Relative sensitivity factors for the quantification of B, P, As, Ga, Ge and Fe have been calculated. Methods based on electrothermal vaporization (ETV) coupled to ICP-MS and ICP emission spectroscopy (OES) as well as direct current arc OES were used for the characterization of metallurgical grade Si powder with concentrations in the µg g−1 range. Total reflection X-ray fluorescence was used as a method for bulk impurity concentration analysis. The spectrum of methods is complemented by surface analysis of silicon wafers by laser ablation (LA)-ICP-MS. New concepts for quantitative analysis of silicon surfaces by the calibration of LA with dried liquid standards were elaborated. It has been demonstrated that this method is suitable for the detection of typical metallic precipitations in silicon like copper silicide. For validation of the methods, instrumental neutron activation analysis was used as the generally accepted reference method in the semiconductor industry.
305

Analyse von Kunststoffadditiven mittels Laserablation gekoppelt mit induktiv gekoppelter Plasma Massenspektrometrie

Börno, Fabian 29 November 2016 (has links)
Die Laserablation gekoppelt mit der Massenspektrometrie mit induktiv gekoppeltem Plasma ist eine vielversprechende direkte Feststofftechnik, die sich jedoch bei der Analyse von Kunststoffen wegen des Mangels an matrixangepassten zertifizierten Referenzmaterialien nicht durchsetzen konnte. Vorherige Arbeiten belegen polymerabhängige Abtragsraten. Das oft als interner Standard verwendete Intensitätssignal des Kohlenstoffisotopes 13C zur Korrektur dieser Unterschiede wird in der Literatur kritisch diskutiert. In dieser Arbeit als ein Teil des BMBF-geförderten MaxLaP-Projektes wurden matrixangepasste Standards auf Polyethylen- und Acrylnitril-Butadien-Styrolbasis entwickelt. In diese Standards wurden Br, Cd, Cu, Cr, Fe, Sb in organischer und anorganischer Form ihrer Verbindungen mittels Extrusion eingearbeitet. Die quantitative Zusammensetzung der Materialien wurde mittels ETV-ICP-OES, DC-arc-OES, RFA und ICP-MS nach Mikrowellendruckaufschluss überprüft. Die Verfahren wurden für die Kunststoffanalyse optimiert. Die mikroskopische Homogenität der Einarbeitung wurde mittels µ-SYRFA und LA-ICP-MS untersucht. Zur Untersuchung der Matrixeffekte während der LA-ICP-MS und der matrixunabhängigen Kalibrierung für Kunststoffe wurden der Einfluss der chemischen Verbindung der Additive, die Größe, der bei der Laserablation gebildeten Partikel und die Art des Kunststoffes auf die Laserablation analysiert. Die Korrektur des verschiedenen Materialabtrages über die Verwendung des 13C-Signals konnte für 21 verschiedene Kunststoffe erfolgreich durchgeführt werden. Allerdings zeigen die zugesetzten Additive ein nicht identisches Verhalten hinsichtlich Transport und Ionisierung. Weitere Ergebnisse belegen eine Anreicherung der Additive in verschiedenen Partikelgrößen sowie eine deutlich unterschiedliche Partikelbildung bei Ablationen von verschiedenen polymeren Matrices, was zu einer verstärkten Elementfraktionierung bei einer nicht matrixangepassten Kalibrierung führt. / Laser ablation coupled to a mass spectrometer with inductively coupled plasma (LA-ICP-MS) is a promising direct solid sampling technique. Due to the lack of matrix matched standard materials laser ablation is not well established in polymer analysis. In a recent study a polymer dependent interaction with the laser beam was reported, which resulted in a polymer depending ablation rate. The usage of the carbon-13-signal intensity as internal standard to correct these differences as commonly applied has been critically discussed in literature. In this work as part of a BMBF-supported MaxLaP-project (matrix effects during laser ablation of polymers) matrix matched standards based on polyethylene and acrylonitrile butadiene styrene were developed. In these materials Br, Cd, Cu, Cr, Fe and Sb were incorporated as organic and inorganic compounds through extrusion. Quantitative composition of the materials was determined by ETV-ICP-OES, DC-arc-OES, XRF and ICP-MS after high pressure microwave digestion. Analytical methods were optimized for trace analysis in plastic matrices. Microscopic homogeneity was examined by µ-SyXRF as well as LA-ICP-MS. In order to investigate the matrix effects and to determine the possibility of a matrix independent calibration for plastic materials, the influence of the chemical form of the additives, size of the formed particles and the type of the plastic on the LA-ICP-MS measurements were analyzed. The correction of the material uptake by the carbon-13-signal was successfully applied for 21 different types of plastic. However, different incorporated additives show a different transport and ionization behavior. Furthermore, our results confirm a different enrichment of the additives depending on particle size and a significantly different particle formation for different types of plastic, which leads to a more pronounced elemental fractionation by not using a matrix matched calibration.
306

Speziation von Gadolinium-MRT-Kontrastmitteln in Umweltmatrizes

Lindner, Uwe 26 July 2017 (has links)
Gd-Kontrastmittel werden in der Medizin für die Magnetresonanztomographie (MRT) benötigt, um einen besseren Bildkontrast zu erzielen. Nach der Anwendung gelangen diese Arzneimittel über das Abwasser in die Klärwerke und von dort in die jeweiligen anliegenden Oberflächengewässer. Somit wird es notwendig, den Verbleib der Gd-MRT-Kontrastmittel in der Umwelt zu verfolgen und aufzuklären. In dieser Arbeit werden für die Analyse von Umweltproben Methoden zur Speziesanalytik von Gd-Kontrastmitteln entwickelt und optimiert. Hierbei wird u.a. die Zwitterionische Hydrophile Interaktionschromatographie (HILIC) verwendet, die mit einer Induktiv- gekoppelten Plasma – Massenspektrometrie (ICP-MS) gekoppelt ist. / Gd based contrast agents are used for medical magnetic resonance imaging (MRI) to enhance the contrast of the image. After application and excretion, the drugs pass through the wastewater treatment plant (WWTP) and make their way into the surrounding surface water bodies. This makes it necessary to monitor the fate of the Gd based contrast agents in the environment. In this work, methods for speciation analysis of Gd based contrast agents in environmental samples were developed and optimised. For this purpose i.a. zwitterionic hydrophilic interaction chromatography (HILIC) is used, which is hyphenated with inductively coupled plasma mass spectrometry (ICP-MS).
307

Untersuchungen zur Aufnahme und Verteilung von gadoliniumbasierten Kontrastmitteln in biologischen Proben mittels Laserablation mit induktiv gekoppelter Plasma-Massenspektrometrie

Lingott, Jana 08 January 2016 (has links)
Gadoliumbasierte Kontrastmittel werden in der Magnetresonanztomographie verwendet und gelangen nach der Exkretion durch behandelte Patienten in Oberflächengewässer, da sie von Klärwerken nur unzureichend entfernt werden. Das Verhalten der Kontrastmittel in der Umwelt und deren Wechselwirkung mit Organismen wurde in dieser Arbeit aufgrund der Toxizität des freien Gd-Ions und der damit verbundenen möglichen Gefahren, wie der Anreicherung in der menschlichen Nahrungskette, näher untersucht. Die bildgebenden elementanalytischen Methoden Laserablation mit induktiv gekoppelter Plasmamassenspektrometrie (LA-ICP-MS) und Röntgenfluoreszenzanalyse mit Synchrotronstrahlung (SRXRF) wurden genutzt, um verschiedene biologische Systeme hinsichtlich ihrer Aufnahme, Verteilung und Abgabe von Gd-basierten Kontrastmitteln zu untersuchen. Zuvor wurden beide Methoden für diese Anwendung analytisch charakterisiert und verglichen. Die Nachweisgrenzen von Gadolinium wurden mittels LA-ICP-MS (0.78 pg) und SRXRF (89 pg) unter jeweils optimierten Bedingungen durch die Kalibrierung über Rückstände eingetrockneter Elementstandardtropfen bestimmt. Anhand von Fadenalgen konnte die Aufnahme und Abgabe der Gd-basierten Kontrastmittel gezeigt werden. Die Abhängigkeit von der Konzentration des Kontrastmittels in der Expositionslösung und die Unabhängigkeit der zeitlichen Aufnahme innerhalb eines Zeitraums von 1-7 Tagen wurden an Wasserlinsen studiert. Gadolinium konnte in einem Kresseblatt quantifiziert werden. Die Verifizierung der LA-ICP-MS-Ergebnisse erfolgte mit der SRXRF und der ICP-MS nach Aufschluss. Auch die Aufnahme und Abgabe von Gd in Wasserflöhen wurde beobachtet. Die Lokalisierung des Gds wurde mittels 3D µ-Computertomographie durch den Vergleich mit einem unbelasteten Wasserfloh aufgeklärt. In allen Untersuchungen wurde Gadolinium in den exponierten Modellorganismen nachgewiesen, woraus geschlussfolgert werden kann, dass die Kontrastmittel aus der Umgebung aufgenommen werden. / Gadolinium based contrast agents are used for magnetic resonance imaging. After their excretion by medicated patients they reach surface water passing waste water treat-ment plants where they are not removed sufficiently. The behavior of the contrast agents in the environment and the interaction with organisms was investigated in this work due to the toxicity of the free Gd3+ ion and the associated risks, such as accumulation in the human food chain. In this work, the two elemental analytical imaging methods laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and synchrotron radiation X-ray fluorescence analysis (SRXRF) have been used to investigate the uptake, distribution, and excretion of Gd-based contrast agents by various biological systems. Both methods were analytically characterized and compared for this application. The detection limits of gadolinium were determined under optimized conditions by LA-ICP-MS and SRXRF. With calibration by remains of dried elemental standard droplets detection limits of 0.78 pg absolute amount of gadolinium (LA-ICP-MS), respectively 89 pg (SRXRF) were reached. Based on filamentous algae as water plants the uptake and the excretion of Gd-based contrast agents were revealed. The dependence on concentration of the contrast agent in the exposition solution and the independence of temporal uptake within one to seven days were studied for duckweed. By LA-ICP-MS gadolinium was quantified in a leaf of cress plant. The verification of the results was performed by SRXRF and ICP-MS after digestion. Furthermore, the uptake and distribution of Gd-based contrast agents in higher organisms (water flea) were observed. The exact location of gadolinium was resolved by three-dimensional μ-computed tomography by the comparison of an exposed with a Gd-free water flea. In all studies, gadolinium was detected in the investigated exposed model organisms. It can be concluded that the contrast agents were taken from the environment.
308

Développement de la méthodologie analytique et surveillance des contaminants dans le panier de la ménagère au Liban / Analytical methods development and survey of selected contaminants in a Lebanese food basket

Bou Khouzam, Rola 12 December 2011 (has links)
L’objectif du travail est d’évaluer le niveau des contaminants (éléments à l’état de traces et pesticides) dans quatre types de produits alimentaires (pain, fromage, végétaux et fruits) et eau potable considérés parmi les produits les plus consommés par les Libanais suivant l’étude du panier de la ménagère faite en 2006. Une méthode analytique pour l’analyse multi élémentaire a été optimisée pour augmenter la sensibilité et réduire les interférences polyatomiques en utilisant la technique de spectrométrie de masse de haute résolution par plasma induit pour la détermination de 20 éléments mineurs et à l’état de trace afin d’évaluer la valeur nutritive et le niveau de contamination. Pour l’analyse des résidus de pesticides, une méthode analytique a été développé pour la détermination des résidus dans des fromages riches en matières grasses (2-25%). La détermination des résidus de pesticides dans le pain, les végétaux et les fruits a été accomplie suivant la méthode QuEChERS. La surveillance du taux des contaminants a été faite sur des échantillons collectés dans des marches de cinq régions géographiques au Liban durant les saisons humide et sèches. / The objective of this work was to evaluate the level of food contaminants, trace elements and pesticides residues, in four types of commodities bread, white cheese, vegetables and fruits, and drinking water considered as the most consumed by the Lebanese population based on the Food Basket Study on 2006. A multielemental method was optimized in terms of sensitivity and inference elimination by using high resolution sector field inductively coupled plasma mass spectrometry (HR ICP/MS) for the determination of 20 minor and trace elements in the selected foods to assess the nutritional contribution and the level of contamination. For pesticides residues analysis, an analytical method was developed for the quantification of residues in cheese (2-25% fat). Bread, vegetables and fruit were analysed according to the QuEChERS method. For the monitoring study, the samples were collected during two seasons, wet and dry, from five geographical regions in Lebanon.
309

Développement d’une approche analytique pour la caractérisation du sélénoprotéome in vivo / Development of analytical methodology for selenoproteomics

Bianga, Juliusz 21 February 2013 (has links)
Le sélénium est un micronutriment essentiel pour des nombreux organismes vivants, y compris l’homme. Son rôle est lié à sa présence dans des sélénoprotéines sous forme d’un acide aminé, génétiquement encodé – la sélénocystéine. Il y a 25 sélénoprotéines encodées dans le génome humain. Leurs fonctions, la cinétique et la hiérarchie d'expression se trouvent au cœur des problématiques de recherche concernant le sélénium et la santé humaine. Il existe également un autre type de protéines où le sélénium est inséré par un remplacement partiel du soufre dans la méthionine mais aussi, potentiellement, dans la cystéine. Ces protéines suscitent l’intérêt dans les sciences de nutrition comme source de sélénium biodisponible dans l’alimentation naturelle et supplémentée. L'objectif de cette thèse a été la mise au point de méthodologies analytiques visant la spéciation du sélénium incorporé dans les protéines à l’échelle du protéome entier. Une procédure inédite a été développée pour la détection globale de protéines séléniées dans des gels d’électrophorèse bidimensionnelle par l’imagerie d’ablation laser ICP MS (spectrométrie de masse plasma à couplage inductif) permettant de s’affranchir de l’utilisation de l’isotope radioactif 75Se. Les autres avancées comprennent la mise en place d’un couplage robuste de HPLC capillaire avec l’ICP MS pour la détection des sélénopeptides dans des microvolumes de digestats trypsiques des protéines extraites du gel ainsi que la mise en place des protocoles d’identification des protéines séléniées par la spectrométrie de masse électrospray en tandem utilisant la trappe orbitale (Orbitrap). Les méthodes développées ont permis (i) la caractérisation de la part du protéome sélénié contenant la sélénocystéine chez la levure séléniée, (ii) l’identification des protéines majeures qui accumulent le sélénium dans le blé, et (iii) le dosage semi quantitatif et la caractérisation globale des sélénoprotéomes (GPx1, GPx4, TRxR1, TRxR2, Sel15kDa) dans les lignées cellulaires. / Selenium is an essential micronutrient for many living organisms including man. Its role is related to selenoproteins which contain genetically encoded selenocysteine. There are 25 selenoproteins encoded in the human genome. Their function, expression kinetics and hierarchy have been a topic of intense research in life sciences. There is another type of proteins which contain selenium inserted non-specifically by partly replacing sulphur in methionine and, potentially, cysteine. They are of interest in nutrition science as source of bio-available selenium in natural and supplemented foods. The goal of this Ph.D. was the development of methodologies for the analysis of selenium-containing proteins on the entire proteome scale. A novel procedure was developed for their global detection in 2D electrophoretic gels par laser ablation inductively coupled plasma mass spectrometry (ICP MS) imaging permitting to avoid the use of the radioactive 75Se. The other developments included (i) a robust capillary HPLC – ICP MS coupling allowing the detection of Se-containing peptides in microliter volumes of the digests of proteins extracted from the gel and (ii) protocols allowing the targeted identification of the Se-containing proteins by a parallel capillary HPLC - electrospray Orbitrap MS/MS. The methods developed allowed (i) the characterisation of the selenocystein-containing part of the selenoproteome of Se-enriched yeast, (ii) identification of the major Se-accumulating proteins in wheat, and (iii) semiquatitive analysis and global identification of the selenoproteomes (GPx1, GPx4, TRxR1, TRxR2, Sel15kDa) expressed in different human cell lines.
310

Développements analytiques pour la spéciation de l’uranium dans les branchies du poisson zèbre (Danio rerio) après exposition / Analytical developments for the speciation of uranium in zebrafish (Danio rerio) gills after exposure

Bucher, Guillaume 22 November 2013 (has links)
L’objectif de cette thèse porte sur l’étude de la compartimentalisation cellulaire et de la prise en charge de l’uranium (U) par les protéines cytosoliques des cellules branchiales du poisson zèbre (Danio rerio, espèce modèle en toxicologie aquatique) après exposition contrastées (chronique vs. aiguë, 20 et 250 µg.L-1) par voie directe. Cette étude a nécessité le développement, l’utilisation et le couplage d’outils analytiques de pointe (SEC, IEF hors-gel, RP-UHPLC pour la séparation, ICP-SFMS, ESI-FTMS/MS pour la détection) avec comme défis majeurs la conservation des interactions non-covalentes U biomolécule et une sensibilité maximale pour travailler à des niveaux d’exposition proches de ceux rencontrés dans l’environnement. Après extraction, 24 à 32% de la charge branchiale totale en U est contenue dans le cytosol dans lequel la distribution de l’U sur les biomolécules (en fonction de leur PM mais aussi de leur pI) diffère selon le niveau d’exposition. Enfin, une cartographie des biomolécules cibles de l’U a permis (i) de mettre en évidence une affinité particulière de l’U pour les protéines à caractère acide et/ou contenant du phosphore et (ii) d’identifier 24 protéines candidates pour lier U. / The objective of this thesis is to study the cellular compartmentalization and the chelation of uranium (U) by cytosolic proteins of gill cells of the zebrafish (Danio rerio, model species in aquatic toxicology) under different direct exposure conditions (chronic vs. acute, 20 and 250 µg.L 1). This study required the development of hyphenated techniques (SEC, IEF off-gel, RP-UHPLC for the separation, ICP-SFMS, ESI-FTMS/MS for the detection) with the main challenges of maintaining the non-covalent U-biomolecule interactions and enhancing sensitivity for the analysis of environmentally relevant samples. After extraction, 24% to 32% of the total U detected in the gills were present in the cytosolic fraction, in which the U distribution on the biomolecules (as a function of their MW and pI) varied depending on the exposure level. Finally, U target biomolecules mapping allowed us (i) to highlight a particular affinity of U for acidic and/or P-containing proteins and (ii) to identify 24 protein candidates for U binding.

Page generated in 0.04 seconds