• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 19
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 73
  • 23
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Chambres MICROMEGAS pour la calorimétrie hadronique, recherche d'une nouvelle physique dans le domaine du quark top

Espargiliere, Ambroise 21 September 2011 (has links) (PDF)
La première partie rapporte la caractérisation de prototypes de chambre MICROMEGAS en tests sous faisceaux et en laboratoire. L'étude détaille notamment l'efficacité de détection, la multiplicité de la réponse et dépendance du gain du détecteur vis à vis des conditions environnementales. Dans la seconde partie, La détection d'un boson de jauge Z', prédit par différends modèles de types Randal-Sundrum est étudiées dans le cadre de l'expérience CLIC. Le canal considéré implique l'émission du Z' par une paire de quarks top. Le Z' se désintègre ensuite en particules de matière noire.
52

Développement de capteurs à pixels CMOS pour un détecteur de vertex adapté au collisionneur ILC

Fu, Yunan 09 May 2012 (has links) (PDF)
Le travail de thèse a consisté, en priorité, à s'approprier les technologies d'intégration verticale en usage dans l'industrie pour réaliser des mémoires à plusieurs étages, et à en évaluer l'apport pour les capteurs à pixel CMOS (CPS). Cette approche s'appuie sur la capacité de l'industrie à interconnecter des puces amincies empilées les unes sur les autres. Elle ouvre la perspective d'associer plusieurs microcircuits superposés à un même pixel, en dépits de sa taille réduite. L'interconnexion est donc réalisée au niveau du pixel. Ce saut technologique permet de lever la majorité des obstacles à l'obtention de performances optimales des CPS. On peut en particulier combiner des puces réalisées dans des technologies CMOS très différentes, chacune optimale pour une fonctionnalité précise. La collection des charges du signal peut ainsi être réalisée dans une couche dédiée, les microcircuits de conditionnement analogique des signaux peuvent être concentrés dans une autre couche, une troisième couche pouvant héberger les parties numériques assurant la compression puis la transmission des signaux, etc. Ce progrès se traduit notamment par la possibilité de combiner haute résolution spatiale et lecture rapide, avec une amélioration probable de la tolérance aux rayonnements intenses.On s'affranchit de cette manière des limitations provenant des paramètres de fabrication des fondeurs, qui ne permettent pas à l'heure actuelle, de pleinement exploiter le potentiel des CPS à l'aide d'une technologie CMOS unique.
53

Forward-Backward asymmetry in top pair production at the ILC

Amjad, Muhammad Sohail 04 February 2014 (has links) (PDF)
This thesis is done in the framework of the ILC. The determination of the electroweak couplings of the top quark, is one of the tasks at the ILC. The thesis is dedicated to the measurement of the Forward-backward asymmetry in top quark pairs, at 500 GeV, using two beam polarization configurations, in the fully hadronic decay channel. The top quark almost exclusively decays to a b quark and a W boson. The 6 jet final state is analyzed using full detector simulation. Two jets with highest b-tag are taken as b jets and the remaining four jets are used to reconstruct the W s. The identification of the top and anti-top quarks is done by using the vertex charge of the b quark. Precisions on the production cross sections are also calculated. This thesis also includes a chapter on the optimization of the Si-W Electromagnetic calorimeter of the International Large Detector (ILD), one of the two detectors at the ILC. The ECAL of ILD, will consist of alternate layers of Silicon and Tungsten, where Silicon layers are active layers, while Tungsten is passive material. The Silicon layers are divided into wafers, surrounded by guard rings, to avoid the leakage currents. The analysis is focused to optimize the guard ring size. The thesis is divided into 6 chapters. The first chapter gives a brief over view of the Standard Model. The second chapter is dedicated to the theoretical aspects of the top quark physics at the ILC. A detailed description of the ILD and its sub-detectors is given in the 3rd chapter. The 4th chapter presents the studies of the optimization of Si-W ECAL guard ring size. The 5th chapter contains the details of analysis of tt production at ILC, and measurement of the AFBt . The last chapter contains the summary of the results.
54

Dynamique des faisceaux dans la section finale de focalisation du futur collisionneur linéaire / Beam dynamics in the final focus section of the future linear collider

Blanco, Oscar 03 July 2015 (has links)
L’exploration d’une nouvelle physique à l’échelle d’énergie des « Tera electron Volt » (TeV) nécessite de collisionner des leptons dans de grands accélérateurs linéaires à grande luminosité. Ces collisionneurs linéaires requiert une taille de faisceau à l’echelle nanométrique au Point d’Interaction (IP).Parmi les multiples effets participant à la degradation de la luminosité, la correction de la chromaticité, l’effet du rayonnement synchrotronique et la correction des erreurs dans la ligne sont parmi les trois effets à maîtriser afin de réduire la taille du faisceau dans la Section Finale de Focalisation (FFS).Cette these propose un nouveau schéma de correction de la chromaticitè que l’on appelera “non-entrelacé”, appliqué ici au projet CLIC. Lors de l’implementation de cette nouvelle methode, il a été mis en evidence que le probléme principal est la dispersion de deuxième ordre au Doublet Final (FD), qui traverse un sextupole utilisé pour annuler les composantes géometriques restantes.L’effet du rayonnement peut être evalué par méthode de tracking des particules ou par des approximations analytiques. Afin d’inclure ces effets du rayonnement et les paramétres optiques de la ligne pendant la conception et le processus d’optimisation, l’effet Oide et le rayonnement dû aux aimants dipolaires ont été etudiés.Le résultat analytique du rayonnement synchrotronique dans les aimants dipolaires fut generalisé dans les cas avec alpha et dispersion non-nulles à l’IP. Cette généralisation est utilisée pour améliorer le code de simulation PLACET.Le rayonnement dans les aimants quadripolaires finaux imposent une limite à la taille verticale minimale du faiceau, connu comme l’effet Oide. Celui-ci est uniquement important à 3 TeV, donc deux possibilités sont explorées pour atténuer sa contribution dans la taille du faisceau : doubler la longueur et réduire le gradient du dernièr quadripole (QD0), ou integrer une paire d’aimants octupolaires, un en amont et un en aval du QD0.Une partie des exigences du FFS pour les nouveaux collisionneurs linéaire à leptons est testée expérimentalement dans l’« Accelerator Test Facility » (ATF). La réduction de la taille du faisceau d’électrons en utilisant le schéma local de correction de la chromaticité est explorée dans une extension de la ligne originale, appellé ATF2, oú deux buts furent fixés : atteindre 37 nm de taille verticale du faisceau à l’IP, et stabiliser de l’ordre du nanomètre la position verticale du faisceau à l’IP. Depuis 2014, une taille de 44 nm avec un nombre de particules d’environ 0.1 × 10^10 par paquet est atteint de manière regulière.Des cavités radio-frequence seront utilisées pour la stabilisation du faisceau, et également pour détecter le déplacement/les fluctuations du faisceau au dehors la marge tolerable pour le systéme de mesure, ainsi que des erreurs non detectées dans l’optique.Un set de trois cavités furent installées et sont utilisées pour mesurer la trajectoire du faiceau dans la région de l’IP, fournissant ainsi des informations pour reconstruire la position et l’angle à l’IP. Les specifications pour l’optique nominale d’ATF2, i.e. 1 nm de résolution sur 10 μm de gamme dynamique à un nombre de particules de 1.0 × 10^10 par paquet, n’ont pas encore été atteint.La meilleur résolution atteinte jusqu’ici correspond à 50 nm pour 0.4 × 10^10 particules par paquet, où le bruit de l’éléctronique impose une limite de 10 nm par cavité sur la résolution. La gamme dynamique est de 10 μm à 0.4 × 10^10 particules par paquet et 10 dB d’attenuation du signal des cavités, nécéssitant de mettre l’électronique à niveau. Le test du système d’asservissement pour stabiliser le faisceau a atteint une réduction de la fluctuation jusqu’a 67 nm, compatible avec la résolution des cavités. / The exploration of new physics in the “Tera electron-Volt” (TeV) scale with precision measurements requires lepton colliders providing high luminosities to obtain enough statistics for the particle interaction analysis. In order to achieve design luminosity values, linear colliders feature nanometer beam spot sizes at the Interaction Point (IP).Three main issues to achieve the beam size demagnification in the Final Focus Section (FFS) of the accelerator are the chromaticity correction, the synchrotron radiation effects and the correction of the lattice errors.This thesis considers two aspects for linear colliders: push the limits of linear colliders design, in particular the chromaticity correction and the radiation effects at 3 TeV, and the instrumentation and experimental work on beam stabilization in a test facility.A new chromaticity correction scheme, called non-interleaved, is proposed to the local and non-local chromaticity corrections for CLIC. This lattice is designed and diagnosed, where the main issue in the current state of lattice design is the non-zero second order dispersion in the Final Doublet (FD) region where a strong sextupole is used to correct the remaining geometrical components.The radiation effect can be evaluated by tracking particles through the lattice or by analytical approximations during the design stage of the lattices. In order to include both, radiation and optic parameters, during the design optimization process, two particular radiation phenomena are reviewed: the Oide effect and the radiation caused by bending magnets .The analytical result of the radiation in bending magnets in was generalized to the case with non-zero alpha and non-zero dispersion at the IP, required during the design and luminosity optimization process. The closed solution for one dipole and one dipole with a drift is compared with the tracking code PLACET, resulting in the improvement of the tracking code results.The Oide effect sets a limit on the vertical beamsize due to the radiation in the final quadrupole. Only for CLIC 3 TeV this limit is significant, therefore two possibilities are explored to mitigate its contribution to beam size: double the length and reduce the QD0 gradient, or the integration of a pair of octupoles before and after QD0.Part of the requirements of the FFS for new linear accelerators are tested in The Accelerator Test Facility (ATF). The beam size reduction using the local chromaticity correction is explored by an extension of the original design, called ATF2 with two goals: achieve 37 nm of vertical beam size at the IP, and the stabilization of the IP beam position at the level of few nanometres. Since 2014 beam size of 44 nm are achieved as a regular basis at charges of about 0.1 × 10^10 particules per bunch.A set of three cavities (IPA, IPB and IPC), two upstream and one downstream of the nominal IP and on top of separate blocks of piezo-electric movers, were installed and are used to measure the beam trajectory in the IP region, thus providing enough information to reconstruct the bunch position and angle at the IP. These will be used to for beam stabilization and could detect beam drift/jitter beyond the tolerable margin and undetected optics mismatch affecting the beam size measurements. The specifications required of 1 nm resolution over 10 μm dynamic range at 1.0 × 10 10 particules per bunch with the ATF2 nominal optics have not been yet achieved.The minimum resolution achieved is just below 50 nm at 0.4 × 10^10 particules per bunch with a set of electronics impossing a noise limit on resolution of 10 nm per cavity. The dynamic range is 10 μm at 10 dB attenuation and 0.4 × 10^10 particules per bunch, indicating the need to upgrade theelectronics. The integration to the ATF tuning instruments is ongoing. Nonetheless, feedback has been tested resulting in reduction of beam jitterdown to 67 nm, compatible with resolution.
55

Development of a CMOS pixel sensor for the outer layers of the ILC vertex detector / Développement d'un capteur de pixels CMOS pour les couches externes du détecteur de vertex ILC

Zhang, Liang 30 September 2013 (has links)
Le sujet de cette thèse est de concevoir un prototype de capteur à pixel CMOS adapté aux couches extérieures du détecteur de vertex de l'International Linear Collider (ILC).Il est le premier prototype de capteur CMOS intégrant un ADC en bas de colonne de 4-bit et une matrice de pixels, dédié aux couches externes. L'architecture du prototype nommé MIMOSA 31 comprend une matrice de pixels de 48 colonnes par 64 lignes, des ADC en bas de colonne. Les pixels sont lus ligne par ligne en mode d'obturation roulant. Les ADCs reçoivent la sortie des pixels en parallèle achève réalisent la conversion en effectuant une approximation de multi-bit/step. Sachant que dans les couches externes de l'ILC, la densité de pixels touchés est de l'ordre de quelques pour mille, !'ADC est conçu pour fonctionner en deux modes (actifs et inactifs) afin de minimiser la consommation d'énergie. Les résultats indiquent que MIMOSA 31 répond aux performances nécessaires pour cette couche de capteurs. / This work deals with the design of a CMOS pixel sensor prototype (called MIMOSA 31) for the outer layers of the International Linear Collider (ILC) vertex detector. CMOS pixel sensors (CPS) also called monolithic active pixel sensors (MAPS) have demonstrated attractive performance towards the requirements of the vertex detector of the future linear collider. MIMOSA 31developed at IPHC-Strasbourg is the first pixel sensor integrated with 4-bit column-level ADC for the outer layers. It is composed of a matrix of 64 rows and 48 columns. The pixel concept combines in-pixel amplification with a correlated double sampling (CDS) operation in order to reduce the temporal and fixed pattern noise (FPN). At the bottom of the pixel array, each column is terminated with an analog to digital converter (ADC). The self-triggered ADC accommodating the pixel readout in a rolling shutter mode completes the conversion by performing a multi-bit/step approximation. The ADC design was optimized for power saving at sampling frequency. Accounting the fact that in the outer layers of the ILC vertex detector, the hit density is inthe order of a few per thousand, this ADC works in two modes: active mode and inactive mode. This thesis presents the details of the prototype chip and its laboratory test results.
56

Development of CMOS sensor with digital pixels for ILD vertex detector / Développement de capteurs à CMOS avec pixel numérique pour le ILD détecteur de vertex

Zhao, Wei 25 March 2015 (has links)
La thèse présente le développement de CPS (CMOS Pixel Sensors) intégré avec CAN au niveau du pixel pour les couches externes du détecteur de vertex de l’ILD (International Large Detector). Motivé par la physique dans l’ILC (International Linear Collider), une précision élevée est nécessaire pour les détecteurs. La priorité des capteurs qui montre sur les couches externes est une faible consommation d’énergie en raison du rapport élevé de couverture de la surface sensible (~90%) dans le détecteur de vertex. Le CPS intégré avec CAN est un choix approprié pour cette application. L’architecture de CAN de niveau colonne ne fournit pas une performance optimisée en termes de bruit et la consommation d’énergie. La conception de CAN au niveau du pixel a été proposée. Bénéficiant des sorties de pixels tout-numérique, CAN au niveau des pixels présentent les mérites évidents sur le bruit, la vitesse, la zone sensible et la consommation d’énergie. Un prototype de capteur, appelé MIMADC, a été implémenté par un processus de 0.18 μm CIS (CMOS Image Sensor). L’objectif de ce capteur est de vérifier la faisabilité du CPS intégré avec les CAN au niveau des pixels. Trois matrices sont incluses dans ce prototype, mais avec deux types différents de CAN au niveau de pixel: une avec des CAN à registre à approximations successives (SAR), et les deux autres avec des CAN à une seule pente (Single-Slope, SS) CAN. Toutes les trois possédant les pixels de la même taille de 35×35 μm2 et une résolution de 3-bit. Dans ce texte, des analyses théoriques et le prototype sont présentés, ainsi que la conception détaille des circuits. / This thesis presents the development of CMOS pixel sensors (CPS) integrated with pixel-level ADCs for the outer layers of the ILD (International Large Detector) vertex detector. Driven by physics in the ILC (International Linear Collider), an unprecedented precision is required for the detectors. The priority of the sensors mounted on the outer layers is low power consumption due to the large coverage ratio of the sensitive area (~90%) in the vertex detector. The CPS integrated with ADCs is a promising candidate for this application. The architecture of column-level ADCs, exists but do not provide an optimized performance in terms of noise and power consumption. The concept of pixel-level ADCs has been proposed. Benefiting from the all-digital pixel outputs, pixel-level ADCs exhibit the obvious merits on noise, speed, insensitive area, and power consumption. In this thesis, a prototype sensor, called MIMADC, has been implemented by a 0.18 μm CIS (CMOS Image Sensor) process. The target of this sensor is to verify the feasibility of the CPS integrated with pixel-level ADCs. Three matrices are included in this prototype but with two different types of pixel-level ADCs: one with successive approximation register (SAR) ADCs, and the other two with single-slope (SS) ADCs. All of them feature a same pixel size of 35×35 μm2 and a resolution of 3-bit. In this thesis, the prototype is presented for both theoretical analyses and circuit designs. The test results of the prototype are also presented.
57

Trajectomètrie dans le cadre du projet européen AIDA / Tracking in the context of the European project AIDA

Cousin, Loic 17 September 2015 (has links)
Ce travail se place dans le contexte du détecteur de vertex (VXD) composé de capteurs CMOS pour l'ILC, et dans celui du télescope en faisceau du projet européen AIDA. La thèse inclut les tests en faisceau des éléments du télescope AIDA : les super-plans SALAT et les échelles double faces PLUME. Elle questionne la valeur ajoutée en terme d'alignement, des couches double faces de capteurs CMOS pour le VXD de l'ILD. Une nouvelle méthode d'alignement autonome de chacune des 3 double couches du VXD grâce aux mini-vecteurs construits sur chaque zone de recouvrement inter-échelle est proposée et a été testée avec des particules de haute impulsion. Cependant, seules les particules du bruit de fond faisceau, de plus basses impulsions, permettent l'obtention d'une statistique suffisante pour cet alignement. Ce bruit de fond a alors été étudié et une estimation des taux d'occupation des capteurs du VXD a conduit à une ré-estimation des vitesses de lecture des capteurs de chaque couche du VXD. / This work was conducted in the context of a vertex detector (VXD) composed of CMOS sensors for ILD and in the context of the beam telescope of the european project AIDA. The provides the results of beam tests for the new telescope components : the SALAT super-planes and the PLUME double sided ladders. The thesis adresses the added value in terms of alignment, of double sided layers of CMOS sensors for the VXD of ILD. A new standalone alignment method of each of the three double sided layers of VXD with the mini-vectors built on each overlapping zone between the consecutive ladders is analysed. Such alignment was validated with high momentum particles. However, only the beam background particles, with lower momentum, can provide the minimum statistic for this kind of alignment. Thus, the beam background noise was studied and the occupancy rate of the VXD sensors was studied. This led to a reassessment of the readout speed for the sensors of each layer of the VXD.
58

The Vienna Convention of 1983: context, failure and aftermath / Wienkonventionen 1983: kontext, misslyckande och följder

Farrell, Gerard January 2021 (has links)
This thesis examines the Vienna Convention on succession of States in respect of State Property, Archives and Debts, which was adopted in 1983 but subsequently failed to enter into force as too few states ratified it. Attention is given to the section of the Convention concerned specifically with the fate of archives in state succession, and the reasons why most of the major western nations, in particular those who had formerly or still possessed colonies, voted against the text. Given that this thesis analyses the failure of the Convention largely in terms of the political and historical circumstances surrounding it, particular attention is given to the context of decolonisation and Third World activism which sought to combat the neocolonial order which followed decolonisation, as well as the relative decline in power of the Third World during the debt crises of the 1980s. The context of historical efforts to resolve archival disputes and create legal frameworks in which to do so is also examined, before considering some of the most irreconcilable points of contention at the conference itself in part three. The concluding section considers some of the criticism leveled at the conference in its aftermath, in particular claims from those western nations which voted against it, while looking at both the subsequent consequences of this failure and the prospects for future agreements. This is a two years master's thesis in Archival Science. / Denna uppsats granskar Wienkonventionen om statssuccession med avseende på statlig egendom, arkiv och skulder, som antogs 1983 men därefter inte trädde i kraft eftersom alltför få stater ratificerade den. Fokus läggs på den del av konventionen som berör statsarkiv specifikt, och skälen till varför de flesta av de stora länderna i väst, särskilt de som tidigare eller fortfarande hade kolonier, röstade emot avtalet. Med tanke på att denna uppsats analyserar misslyckandet av konventionen till stor del med avseende på de politiska och historiska omständigheterna kring den, ägnas särskild uppmärksamhet åt kontexten av avkolonisering och tredje världsaktivismen som försökte bekämpa den neokoloniala ordningen som följde avkoloniseringen, såväl som den relativa maktminskningen i tredje världen under skuldkrisen på 1980-talet. Kontexten för historiska försök att lösa arkivtvister och skapa rättsliga ramar för att göra det undersöks också. Sedan diskuteras några av de mest oförenliga ståndpunkterna vid själva konferensen i del tre. I den avslutande delen granskas en del av den kritik som riktades mot konferensen i dess efterdyningar, särskilt påståenden från de västländer som röstade emot den, samtidigt som man tittar på de efterföljande konsekvenserna av detta misslyckande och utsikterna för framtida avtal.
59

Emittance preservation and luminosity tuning in future linear colliders

Eliasson, Peder January 2008 (has links)
<p>The future International Linear Collider (ILC) and Compact Linear Collider (CLIC) are intended for precision measurements of phenomena discovered at the Large Hadron Collider (LHC) and also for the discovery of new physics. In order to offer optimal conditions for such experiments, the new colliders must produce very-high-luminosity collisions at energies in the TeV regime.</p><p>Emittance growth caused by imperfections in the main linacs is one of the factors limiting the luminosity of CLIC and ILC. In this thesis, various emittance preservation and luminosity tuning techniques have been tested and developed in order to meet the challenging luminosity requirements.</p><p>Beam-based alignment was shown to be insufficient for reduction of emittance growth. Emittance tuning bumps provide an additional powerful preservation tool. After initial studies of tuning bumps designed to treat certain imperfections, a general strategy for design of optimised bumps was developed. The new bumps are optimal both in terms of emittance reduction performance and convergence speed. They were clearly faster than previous bumps and reduced emittance growth by nearly two orders of magnitude both for CLIC and ILC.</p><p>Time-dependent imperfections such as ground motion and magnet vibrations also limit the performance of the colliders. This type of imperfections was studied in detail, and a new feedback system for optimal reduction of emittance growth was developed and shown to be approximately ten times more efficient than standard trajectory feedbacks.</p><p>The emittance tuning bumps require fast and accurate diagnostics. The possibility of measuring emittance using a wide laserwire was introduced and simulated with promising results. While luminosity cannot be directly measured fast enough, it was shown that a beamstrahlung tuning signal could be used for efficient optimisation of a number of collision parameters using tuning bumps in the Final Focus System.</p><p>Complete simulations of CLIC emittance tuning bumps, including static and dynamic imperfections and realistic tuning and emittance measurement procedures, showed that an emittance growth six times lower than that required may be obtained using these methods.</p>
60

Diagnostic de Faisceau par "Laser-Wire" et Mesure Rapide du Spectre de Luminosite au Collisionneur Lineaire International

Poirier, Freddy 06 September 2005 (has links) (PDF)
The International Linear Collider (ILC), a high precision electron-positron machine with centre of mass energy extending up to the TeV scale, is curently being proposed and designed. With unprecedented small beam size and high intensity the ILC aims at luminosities of the order of $10^(34)$~cm$^(-2)$s$^(-1)$. Careful monitoring of the beam parameters that affect the luminosity will be mandatory if these ambitious goals are to be achieved.<br /><br />One of the key parameters is beam emittance, the optimisation of which requires beam size monitors with micron resolution.<br />With this aim, a non-invasive laser-wire monitor prototype was designed, installed and run at the PETRA ring. Prior to its installation, background simulations and measurements were performed to verify that they would be low enough to allow<br /> the laser-wire programme to proceed. A lead-tungstate crystal calorimeter for the laser-wire was commissioned, including a study of temperature dependance, geometrical acceptance and energy response. The first laser-wire measurements of the PETRA positron beam size were then performed. The system, calibration and results are reported here.<br /><br />At the ILC, beam energy spread and beamstrahlung effects modify the luminosity spectrum. Determination of these effects is crucial in order to extract precision physics from threshold scans. In order to provide a run-time diagnostic scheme to address this, a fast luminosity spectrum measurement technique employing forward calorimetry and statistical unfolding was devised, using the Bhabha process at low angles. The scheme is described and first results are presented.

Page generated in 0.0986 seconds