• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1383
  • 114
  • 47
  • 44
  • 44
  • 43
  • 26
  • 16
  • 13
  • 11
  • 11
  • 11
  • 7
  • 6
  • 2
  • Tagged with
  • 1557
  • 886
  • 745
  • 656
  • 292
  • 235
  • 207
  • 162
  • 156
  • 140
  • 139
  • 138
  • 137
  • 136
  • 126
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
641

Efeito de elementos betagenicos na estabilidade de fases e propriedades de ligas de titanio para implantes ortopedicos

Mello, Gisela Martinelli Rocha 03 August 2018 (has links)
Orientador : Rubens Caram Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T22:09:39Z (GMT). No. of bitstreams: 1 Mello_GiselaMartinelliRocha_D.pdf: 3062014 bytes, checksum: c43a5407ea775274589177805f4e9de2 (MD5) Previous issue date: 2004 / Doutorado
642

Caracterização de revestimentos de hidroxiapatia depositados por aspersão termica a plasma sobre a liga Ti-13Nb-13Zr para aplicação em implantes dentarios

Lima, Petronio Medeiros 22 November 2004 (has links)
Orientador : Cecilia Amelia de Carvalho Zavaglia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T02:52:27Z (GMT). No. of bitstreams: 1 Lima_PetronioMedeiros_D.pdf: 6348939 bytes, checksum: 54056cc426bd5ba4ea2e3b938bed037d (MD5) Previous issue date: 2004 / Resumo: A liga Ti-13Nb-13Zr tem sido proposta como um novo biomaterial metálico por apresentar em sua fonnulação alguns dos elementos metálicos de maior biocompatibilidade (Ti, Nb, Zr e Ta), além de apresentar excelente resistência à corrosão e baixo módulo de elasticidade (E). A liga Ti-13Nb-13Zr, foi obtida por metalurgia do pó. Substratos desta liga foram a seguir revestidos com hidroxiapatita (HA) por aspersão ténnica a plasma visando viabilizar a sua utilização como implantes dentários. Foram utilizadas técnicas de caracterização desses substratos revestidos para avaliação dos efeitos da HA sobre a cristalinidade e propriedades fisicas, mecânicas, eletroquímicas e biológicas dos revestimentos. Foram obtidos revestimentos de boa qualidade com baixa porosidade, baixo nível de partículas não fundidas, sem trincas e com boa adesão. O ensaio de resistência ao risco mostrou-se ser um ensaio reprodutível. A liga Ti13Nb-13Zr revestida com HA é ligeiramente mais resistente à corrosão que a liga não revestida. A liga revestida com HA e não revestida não apresentaram efeitos citotóxico frente à cultura de células osteoblástcas testada. A liga revestida com HA apresentou melhor adesão em cultura de células osteoblásticas a longo tempo de estudo in vitro em comparação com a liga Ti-13Nb-13Zr não revestida / Abstract: The Ti-13Nb-13Zr alloy has been proposed as a new metallic biomaterials wich stands out for introducing in its fonnulation three of the four metallic elements of larger biocompatibility (Ti, Nb, Zr, Ta), besides introducing, low elasticity modulus and excellent corrosion resistance. The Ti-13Nb-13Zr alloy was obtained from powder metallurgy. Substrates of this alloy were coated with hydroxyapatite (HA) deposited by thermal plasma aspersion aiming to make possible its utilization in dental implants. There were used techniques of characterization for these coated substrates to evaluate effects of hydroxyapatite on the crystalinity and physical, mechanical, electrochemical and biological properties of the coatings. There were obtained good quality coatings with low porosity, low leveI of not fused particles, without crack and with good adhesion. The resistance scratch test showed to be a reproducible test. The alloy coated HA is lightly more resistant to the corrosion that the uncoated alloy. The alloy coated HA and uncoated did not show any type of cytotoxicity for culture osteoblastic cells. The HA coated a lloy did present better adhesion results for culture osteoblastic cells the long time of study in vitro in comparison to the Ti-13Nb-13Zr alloy uncoated one / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
643

Precisão de medidas lineares em imagens tomograficas

Guedes, Fabio Ribeiro 24 February 2005 (has links)
Orientador: Glaucia Maria Bovi Ambrosano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:10:26Z (GMT). No. of bitstreams: 1 Guedes_FabioRibeiro_M.pdf: 16708948 bytes, checksum: 136372754eec5ecaf8e3293298f9b330 (MD5) Previous issue date: 2005 / Resumo: Foi identificado o fator de magnificação de tomógrafos convencionais e comparado a mangnificação fornecida pelos fabricantes, e a confiabilidade de medidas lineares das imagens tomográficas corrigidas, quando comparadas às mensurações reais nos segmentos ósseos. Foram utilizadas 16 mandíbulas humanas maceradas edêntulas, e selecionada região correspondente aos incisivos, caninos, pré-molares e molares bilateralmente. Em cada região foram fixados sobre a crista óssea e na região vestibular, um fio ortodôntico com 5,0 milímetros de comprimento, que foi utilizado como guia radiográfico. Os equipamentos utilizados neste trabalho foram os tomógrafos convencionais Quint Sectograph, Orthopantomograph OP100, X Mind TOME, e computadorizados Somatom Esprit com reconstrução multiplanar e Toshiba X vision EX com software Denta Scan. As mandíbulas foram posicionadas nos tomógrafos convencionas conforme as especificações dos fabricantes e obtidas as imagens. Para os tomógrafos computadorizados as mandíbulas foram posicionadas com suas bases perpendiculares ao solo e obtidas as imagens axiais ara posterior reconstrução oblíquo-sagital das regiões. Após obtidas as imagens, foram mensuradas a altura e espessura óssea de cada região, corrigindo-se as medidas com base a ampliação do guia radiográfico e em seguida com o fator de magnificação dado pelo fabricante. As mandíbulas foram seccionadas exatamente nas regiões selecionadas, e realizadas as medidas da altura e espessura óssea, obtendo-se os valores reais por região. As magnificações calculadas, por meio do guia radiográfico dos tomógrafos convencionais, foram comparados pelo teste t, com os fornecidos pelos fabricantes, observando-se diferenças significativas para os três tomógrafos convencionais. A altura e espessura óssea corrigidas pela ampliação do guia radiográfico apresentaram diferenças estatisticamente significativas (p<0,05) pelo teste de Dunnett para as medidas do tomógrafo computadorizado Somatom Esprit quando comparadas com as dimensões reais. A medida da altura óssea corrigida com o fator de magnificação fornecido pelo fabricante demonstrou diferenças para os tomógrafos (p<0,05) com exceção do tomógrafo computadorizado Toshiba X vision EX, e para espessura óssea observou-se diferenças para o tomógrafo Quint Sectograph e Somatom Esprit quando comparados com as dimensões reais (p<0,05). Concluiu-se que as diferenças de magnificação calculadas, comparadas com as fornecidas pelos fabricantes não possuem significância clínica. As mensurações da altura e espessura ósseas foram precisas com exceção das realizadas no tomógrafo computadorizado com reconstrução multiplanar Somatom Sprit / Abstract: The magnification factors of conventional tomography was identified and compared them to the factors provided by the manufacturers, and the reliability of linear measurements achieved on corrected tomographic images, when compared to the real measurements on the bone segments. Sixteen dry edentulous human mandibles were used, and the area corresponding to the incisors, canines, premolars and molars were selected bilaterally. A 5.0-mm long orthodontic wire was fixated on the bone crest and buccal region of each area, to be used as a radiographic guide. The equipments used in this study were the conventional tomography Quint Sectograph, Orthopantomograph OP100, X Mind TOME, and the computerized tomography Somatom Esprit with multiplanar reconstruction and Toshiba X Vision EX with the Denta Scan software. The mandibles were positioned on the conventional scanners following the manufacturers¿ instructions, and the images were obtained. As to the computerized scanners, the mandibles were positioned with their bases perpendicular to the ground, and axial images were achieved for later oblique-sagittal reconstruction of the regions. After achievement of the images, the bone height and thickness of each region were measured, with correction of measurements based on the magnification of the radiographic guide and then according to the magnification factor supplied by the manufacturer. The mandibles were sectioned at the selected areas and bone height and thickness were directly measured, for achievement of the real values for each region. The magnification factors calculated by utilization of the radiographic guide for the conventional tomography were compared to those provided by the manufacturers by the t test, which revealed significant differences for the three conventional scanners. The bone height and thickness with correction according to magnification of the radiographic guide presented statistically significant differences (p<0.05) according to the Dunnett test for the measurements achieved on the computerized tomography Somatom Esprit compared to the real dimensions. The bone height corrected according to the magnification factor provided by the manufacturer demonstrated differences for the scanners (p<0.05), except for the computerized tomography Toshiba X vision EX, with differences in bone thickness for the Quint Sectograph and Somatom Esprit tomography compared to the real dimensions (p<0.05). It was concluded that differences between the magnification factors calculated compared to those provided by the manufacturers do not have any clinical implication; also, measurements of bone height and thickness were reliable, except for those achieved on the computerized tomography with multiplanar reconstruction Somatom Sprit / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
644

Avaliação histometrica do efeito da fumaça de cigarro sobre o reparo e qualidade ossea ao redor de implantes de titanio em ratas com deficiencia induzida de estrogeno

Carvalho, Marcelo Diniz 22 February 2005 (has links)
Orientadores: Enilson Antonio Sallum, Francisco Humberto Nociti Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:11:36Z (GMT). No. of bitstreams: 1 Carvalho_MarceloDiniz_M.pdf: 838460 bytes, checksum: d0aff5d2298e732ab336cd58428d002a (MD5) Previous issue date: 2005 / Resumo: O objetivo do presente estudo foi avaliar a influência da fumaça de cigarro na presença da deficiência de estrógeno sobre o reparo ósseo ao redor de implantes de titânio. Foram utilizadas 45 ratas (Wistar) divididas em 3 grupos: ovariectomia simulada (SHAM, n=15), ovariectomia (OVX, n=15) e exposição a fumaça de cigarro (EFM) associada a OVX (EFM+OVX, n=15). No grupo EFM+OVX, a EFM iniciou-se 60 dias antes da colocação dos implantes e manteve-se até o fim do período experimental. Todos animais receberam um implante em uma das tíbias e no mesmo período cirúrgico foram realizadas as OVX e SHAM. Sessenta dias após as cirurgias, os animais foram mortos e secções não descalcificadas obtidas para avaliação dos seguintes parâmetros: porcentagem de osso na região adjacente ao implante (500 µm) (OA), porcentagem de preenchimento ósseo dentro dos limites das roscas de cada implante (PR) e porcentagem de contato ósseo direto com a superfície do implante (CD). As medidas foram obtidas separadamente para região A (cortical) e B (medular). Os resultados deste estudo mostraram que, na região A, o grupo EFM+OVX apresentou uma menor OA e um menor CD quando comparado aos outros grupos (p<0,05). Na região B, menores valores de CD e OA foram observados no grupo EFM+OVX, seguidos dos grupos OVX e SHAM, respectivamente (p<0,05). Já para PR, os grupos EFM+OVX e OVX se comportaram de maneira semelhante diferindo do grupo SHAM (p<0,05). Conclui-se que, dentro dos limites deste estudo, a exposição à fumaça de cigarro amplificou os efeitos da deficiência de estrógeno, prejudicando a qualidade e o reparo ósseo ao redor de implantes de titânio inseridos em tíbias de ratas ovariectomizadas / Abstract: Background: Smoking has been considered one of the main risk factors for osteoporosis. Cigarette smoke inhalation and estrogen deficiency have been proving to negatively affect bone healing around titanium implants. Thus, the purpose of this study was to investigate the effect of cigarette smoking inhalation on bone around titanium implants in estrogen deficiency rats. Methods: Fourth-five female wistar rats had the tibia surface exposed for the placement of a screw-shaped titanium implant (4.0mm in length; 2.2mm in diameter). The animals were randomly assigned to group SHAM (sham operated rats / n=15), group OVX (ovarectomized rats / n=15) and group CSI+OVX (2 months of intermittent cigarette smoke inhalation (CSI) prior and 2 months after implant placement in ovariectomized rats/ n=15). The implants were placed at the same time of OVX or Sham surgery. After 60 days the animals were sacrificed and undecalcified sections obtained. Percentage of bone in a 500mm-wide zone lateral to the implant (BO), bone filling within the limits of the threads (BF) and bone-to-implant contact (BC) was measured in cortical (zone A) and cancellous (zone B) bone separately. Results: Data analysis showed that, in zone A, a decreased BO and BC was observed for CSI+OVX (p <0.05). In zone B, the CSI+OVX group showed the lowest values for BO and BC, followed by groups OVX and SHAM, respectively (p<0.05). Similar values of BF were observed for CSI+OVX and OVX groups, that were lower than the ones obtained by SHAM group (p <0.05). Conclusion: Within the limits of the present investigation, cigarette smoke inhalation amplified the effects of estrogen deficiency on bone around titanium implants inserted in ovariectomized rats / Mestrado / Periodontia / Mestre em Clínica Odontológica
645

Analise fotoelastica da distribuição de tensões em proteses totais fixas implanto-suportadas

Bastos, Poliana Lima 25 February 2005 (has links)
Orientador: Mauro A.A. Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:50:29Z (GMT). No. of bitstreams: 1 Bastos_PolianaLima_M.pdf: 3116472 bytes, checksum: 1ef54b4bfd3a59b4b3d79ac8ff9a99e7 (MD5) Previous issue date: 2005 / Resumo: Este trabalho avaliou, por meio de análise fotoelástica, a distribuição de tensões ao redor de implantes que suportam próteses totais fixas. O modelo foi confeccionado com resina fotoelástica PL-2 (Vishay Measurements Group, USA), onde foram posicionados seis implantes de 3,75 X 11mm (Conect AR, Conexão Sistemas de Prótese, São Paulo, SP). Foram avaliadas dois sistemas de próteses totais fixas: o protocolo convencional de Brânemark , onde foi confeccionada uma estrutura em titânio (GI) e a prótese fixa destacável (Gil), também confeccionada em titânio, com acréscimo de dois attachments (MK1 Universal Attachments, Sande, Germany). Para os dois grupos, utilizou-se a técnica do cilindro cimentado, na qual cilindros pré-fabricados foram cimentados à estrutura metálica. Inicialmente, as estruturas foram avaliadas quanto às discrepâncias marginais em microscópio óptico com precisão de 0,5/lm e aumento de 120x (UHL VMM-100-BT; Renishaw; UK) associado a um equipamento de leitura digital (Quadra-Check 200; Metronics Inc, Canadá). O método fotoelástico com polariscópio circular foi utilizado para avaliar a distribuição de tensões após prova da estrutura metálica e instalação da prótese, bem como para registrar esse comportamento, por meio de fotografias. Um carregamento oclusal de 100N foi aplicado em 3 pontos individualmente: A (região distal do segundo pré-molar direito), B (regiãodistal do segundo pré-molar esquerdo) e C (região palatina, entre os incisivos centrais). Para as discrepâncias marginais, o GI exibiu menor desajuste (52,1Oum) em relação ao Gil (66, 49um). Os resultados fotoelásticos não mostraram diferenças significativas entre os dois grupos. Observou-se maior concentração de tensões na cervical, no corpo e no ápice dos implantes anteriores, enquanto que nos implantes posteriores, houve maior concentração na região apical. Além disso, o padrão de franjas aumentou gradativamente como resultado da seqüência dos procedimentos laboratoriais. A distribuição de tensões mostrou-se similar entre a prótese do tipo protocolo convencional de Brânemark e a prótese fixa destacável / Abstract: The present study evaluated the stress distribution around osseointegrated implants restored with complete fixed dentures by photoelastic analysis. A photoelastic model of an edentulous maxilla was fabricated (PL-2; Vishay Measurements Group, USA) with 6 implants 3.75x11mm (Conect AR; Conexao Sistema de Protese, Sao Paulo, Brazil). Two complete fixed dentures were evaluated: the conventional Branemark protocol-type rehabilitation technique (GI) with cast titanium framework; and, a fixed-detachable denture (Gil) made from cast titanium incorporating 2 attachments (MK1 Universal Attachments, Sande, Germany). For both groups, the frameworks were manufactured using the cemented-cylinder incorporation technique, where pre-fabricated prosthetic cylinders were cemented to the castings. Initially, ali the frameworks were evaluated for marginal discrepancies in a 0.5mm-accurate optical traveling microscope x120 magnification (UHL VMM-100-BT; Renishaw, UK) equipped wit a digital measurement read-out system (Quadra-Check 200; Metronics Inc, Canada). The photoelastic method with a circular polariscope was used to evaluate the stress distribution after the try-in and installation of the frameworks on the implants. Loads of 100 N were applied to specific points of the frameworks: A (right posterior second pre-molar), B (left posterior second pre-molar) and C (palatal to central incisors). Photographs were taken from the photoelastic fringes after loading around the implants with different magnifications. For marginal discrepancies, the GI exhibited lower gaps (52.10um) than Gil (66.49um). Regarding to the stress distribution, no significant differences were found between the groups. A transfer of load was observed in apical, distal and mesial regions in the anterior implants. For posterior implants, stress was concentrated in the apical regions. The tensions produced around the implants were gradually increased as the laboratorial procedures were accomplished. Stress distribution was similar to conventional Branemark protocoltype and fixed-detachable dentures / Mestrado / Protese Dental / Mestre em Clínica Odontológica
646

Analise fotoelastica da distribuição de tensões induzidas por infra-estruturas implanto-suportadas apos soldagem a laser ou retificação de cilindros

Damaceno, Alessandra Regina Derogis 02 March 2005 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:53:51Z (GMT). No. of bitstreams: 1 Damaceno_AlessandraReginaDerogis_M.pdf: 1414206 bytes, checksum: c7d213655bfe8d988e6311566b91787d (MD5) Previous issue date: 2005 / Resumo: Este estudo avaliou comparativamente duas técnicas indicadas para a obtenção de melhor assentamento de próteses implanto-suportadas através da análise fotoelástica. Para isso, foram obtidos dois grupos de infra-estruturas metálicas em titânio construídas sobre uma matriz metálica com forma e dimensões similares ao arco mandibular, sendo: Grupo 1- três infra-estruturas confeccionadas pela técnica da soldagem de borda a laser de cilindros pré-fabricados; Grupo 2- três infra-estruturas fundidas em monobloco e submetidas ao sistema de retificação de cilindros fundidos. Após avaliação em microscopia óptica, apenas a infra-estrutura mais bem adaptada de cada grupo foi submetida à análise fotoelástica variando-se três seqüências de aperto dos parafusos (1/2/3/4/5, 5/4/3/2/1 e 3/2/4/1/5). De maneira adicional, a infra-estrutura representante do grupo 2 foi submetida, após a primeira análise, à secção e soldagem vertical das partes, e reavaliada. Os resultados mostraram formação de maior quantidade de tensões nas seqüências de aperto 1/2/3/4/5 e 5/4/3/2/1, para ambos os grupos analisados. A estrutura submetida à soldagem de borda de cilindros pré-fabricados mostrou melhores resultados, apesar de a mesma apresentar maiores valores de desadaptação (165µm) quando comparada àquela que teve seus cilindros submetidos à retificação de borda antes (54µm) ou após a secção e soldagem vertical (117µm). A seqüência de aperto 3/2/4/1/5 mostrou melhores resultados. Portanto, o grupo dos cilindros submetidos à soldagem de borda induziu melhores resultados principalmente quando associada à seqüência de aperto 3/2/4/1/5 / Abstract: This study evaluated two techniques indicated to obtain implant-supported fixed prostheses with satisfactory passive fit by means of photoelastic analysis. Two titanium casts groups were fabricated in a metallic master cast: Group I ¿ three frameworks fabricated by laser welded cylinder technique and Group II ¿ three frameworks cast in one-piece and submitted to Rectification Cylinder System. After optical microscopy evaluation, only the better-fit framework of both groups was submitted to the photoelastic analysis, testing three screw tightening sequences (5/4/3/2/1; 1/2/3/4/5 and 3/2/4/1/5). Subsequent to the first analysis, the selective framework of Group II was sectioned and laser welded to be submitted to a new evaluation. Results showed superior stress magnitude in 1/2/3/4/5 and 5/4/3/2/1 sequences of both groups, while 3/2/4/1/5 screw tightening sequence presented better stress results of them. Laser welded cylinder framework illustrated better results, even though had showed superior values of misfit (165µm) compared to the rectified framework before (54µm) and after section and vertical laser welded (117µm). Laser welded cylinder group achieved better results mainly allied to 3/2/4/1/5 screw tightening sequence / Mestrado / Protese Dental / Mestre em Clínica Odontológica
647

Avaliação clinica e histologica da eficacia de enxerto heterogeno organico bovino associado a proteina ossea morfogenetica de embrião bovino em cirurgia de levantamento de seio maxilar

Silva, Fabricio Moreira Serra e 18 February 2005 (has links)
Orientador: Renato Mazzonetto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T05:20:15Z (GMT). No. of bitstreams: 1 Silva_FabricioMoreiraSerrae_M.pdf: 19777334 bytes, checksum: d899078a1e3b8b446e2af4128bdc2219 (MD5) Previous issue date: 2005 / Resumo: O presente estudo teve como objetivo avaliar clinica e histologicamente o comportamento da associação entre uma matriz óssea orgânica bovina (Gen-Ox@) e uma proteína óssea morfogenética (BMP) derivada de embrião bovino (Gen-Pro@), quando comparada com enxerto ósseo autógeno em cirurgias para levantamento bilateral de seio maxilar. Foram operados 10 pacientes não-fumantes e sem alterações sistêmicas, que necessitavam de enxerto bilateral do seio maxilar para futura colocação de implantes osseointegráveis. Em todos os pacientes, foi selecionado um lado como teste e o contra-lateral como controle. Após um período de 6 a 11 meses, foi realizada avaliação clínica da área enxertada e biópsia com broca trefina de 2mm, em região adjacente ao eixo do implante a ser inserido. Os espécimes foram armazenados em formol a 10% e levados para processamento laboratorial para coloração das peças com hematoxilina-eosina e confecção das lâminas. A análise histológica foi realizada por meio de microscopia óptica. Clinicamente, pôde-se observar que a qualidade e quantidade óssea formada no lado preenchido com enxerto autógeno apresentaram um aspecto mais favorável à instalação dos implantes, podendo-se observar uma formação óssea mais completa. Histologicamente, pôde-se observar um padrão de neoformação óssea diferente, com o osso autógeno apresentando um aspecto mais organizado. Com o presente estudo, pôde-se concluir que, clinica e histologicamente, o padrão de formação óssea das áreas enxertadas com a associação de osso heterógeno bovino e proteína óssea morfogenética bovina apresenta um trabeculado ósseo menos compacto e menos organizado do que o osso autógeno / Abstract: The present study aimed to evaluate clinically and histologically the behavior of the association between bovine organic osseous matrix (Gen-Ox@) and bone morphogenetic protein (BMP) (Gen-Pro@), when compared with autogenous bone graft in bilateral maxillary sinus lift procedures. Ten non-smoking and systemically healthy patients who needed bilateral maxillary sinus grafting for the placement of osseointegrated implants were operated. In ali patients, one side was selected as test and the other as control. In a second surgical intervention, the implant placement was preceded by clinical evaluation and biopsy of the lateral sinus wall using with a 2 mm trefine bur, in the region of the bone wall created in the sinus lift procedure. The specimens were stored in 10% formalin and taken to laboratorial processing for hematoxicilin-eosin dying and section preparation. The histological analysis was performed through optical microscopy. Clinically, a better bone formation pattern could be observed in the side grafted with autogenous bone. Histologically, the bone neoformation pattern was different in both sides. In the present study, the association with BMP as a growth factor showed different results when compared to autogenous graft. With the present study, it was possible to conclude that clinically the bone formation pattern is better and more full when autogenous bone is used. Histologically, less compact and less organized bone pattern than with the autogenous bone were found / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
648

Modelación del Micromovimiento en Implantes Dentales Sometidos a Carga Inmediata por el Método de Elementos Finitos

Hurtado Molina, Eladio Enrique January 2011 (has links)
Ingeniero Civil Mecánico / El objetivo general del presente trabajo de título es desarrollar un modelo tridimensional del comportamiento mecánico de implantes dentales sometidos a carga inmediata en el maxilar superior por medio del método de elementos finitos. En las simulaciones se utilizaron diferentes modelos para el hueso y distintas geometrías y materiales para la estructura que une los implantes. Se simuló el proceso de masticación aplicando cargas estáticas sobre la estructura en diferentes posiciones que representan el uso de las distintas piezas dentales en el proceso. En la primera parte del informe se recopilaron todos los antecedentes necesarios para poder plantear el problema de forma correcta, partiendo por los antecedentes odontológicos, los que incluyen información del maxilar superior, de los implantes, del proceso de masticación, del protocolo de carga inmediata y los factores que influyen para obtener una cirugía exitosa. Se explicó el fenómeno físico que hay tras del proceso de reconstrucción de imagen a partir de las tomografías computacionales, técnica que fue utilizada para obtener la geometría del maxilar superior. También se plantearon los modelos matemáticos y numéricos que están involucrados en las simulaciones. Luego se continuó con la modelación en elementos finitos, en donde se detalló la generación de geometrías y mallas, las condiciones de borde y cargas aplicadas, las propiedades de los materiales utilizados y la definición de las zonas de contacto. Como resultado se determinaron los micromovimientos en los implantes, además de esfuerzos, deformaciones y desplazamientos en todos los cuerpos que componen el sistema modelado. Al analizar los resultados se logró encontrar relaciones entre la forma en que varían los valores de micromovimiento obtenidos y los diferentes factores que se variaron en el modelo, tales como geometría y material de la estructura, posición de las fuerzas y modelo para el material del maxilar. Finalmente se concluyó que es posible la simulación del proceso de masticación con cargas estáticas y que es necesario considerar modelos más complejos de material, debido a que se observan cambios importantes en los valores de micromovimiento entre un modelo y otro, en particular al incluir hueso trabecular (modelos heterogéneos). Para modelos homogéneos se obtuvieron micromovimientos entre los 5 y 10 [µm] y para los modelos heterogéneos, los valores obtenidos variaron entre los 20 y 30 [µm]. Con respecto a la influencia de la geometría y de los materiales de la estructura en el micromovimiento, a pesar de que se encontraron relaciones entre los parámetros estudiados, es difícil recomendar una geometría con los datos obtenidos dado que es necesario estudiar más variables involucradas en el problema.
649

Diseño e implementación de un sistema de adquisición y procesamiento de señales mioeléctricas para el reconocimiento en tiempo real de la contracción de los bíceps y tríceps braquiales orientado a la manipulación de un brazo robótico de tres grados de libertad

Alarcón Ramírez, Juan Adolfo, Ruiz Cueva, Luis Enrique, Tello Puerta, Jorge Luis 07 September 2014 (has links)
Hoy en día las personas no están libres de enfermedades o accidentes que, en el peor de los casos, puedan derivar en la amputación de una extremidad. Por lo tanto, para poder reemplazar aquella extremidad se usan las denominadas prótesis. Particularmente la prótesis mioeléctrica de brazo es una extensión artificial que puede ser muy realista, con buena movilidad y puede ser controlada con el pensamiento o el movimiento de determinados músculos del usuario. El desarrollo e investigación de las prótesis mioeléctricas no se da en nuestro país, de la misma forma, dicha prótesis no es muy acogida por parte de las personas amputadas, ya que su precio promedio es de USD $95,000 aproximadamente. El presente proyecto profesional da a conocer la implementación de un prototipo similar a una prótesis mioeléctrica. Este dispositivo logra distinguir entre cinco movimientos del brazo Dichos movimientos se dan tiempo real por medio del procesamiento de dos señales mioeléctricas provenientes del bíceps y tríceps braquiales. Además el prototipo será capaz de manipular objetos livianos. El precio de fabricación de dicho prototipo será de un muy bajo costo comparado con prótesis existente, y está implementada con materiales y dispositivos del mercado local. De esta manera, siendo más asequible para promover el desarrollo e investigación en esta área.
650

Efecto de la liberación controlada del factor de crecimiento plaquetario (PDGF-BB) sobre la proliferación y diferenciación de osteoblastos cultivados sobre un compósito de quitosano-hidroxiapatita

Urbina Guerra, Paulina Francisca January 2011 (has links)
Memoria para optar al Título Profesional de Médico Veterinario / El rápido desarrollo del campo de la ingeniería de tejidos apunta a reemplazar o facilitar la regeneración del tejido dañado, a través de la aplicación de materiales combinados, células y moléculas bioactivas. La alternativa son matrices de polímeros tridimensionales, dentro de los cuales las células son cultivadas. Estas matrices de polímeros, con estructura porosa, han demostrado mejorar la regeneración ósea a través de la creación y mantenimiento de canales que facilitan la migración, proliferación y diferenciación de las células progenitoras. Estas células transplantadas secretan matriz extracelular y factores necesarios para el crecimiento del tejido óseo, mientras que la matriz polimérica se va degradando gradualmente. La estructura porosa tridimensional de estos polímeros permite maximizar la difusión de los productos celulares y el desarrollo vascular dentro de la estructura implantada. El polímero es completamente reabsorbido en un tiempo determinado, permitiendo la nueva formación de tejido. Un tipo de sustituto óseo es el compósito que corresponde a la unión de dos o más sustitutos como por ejemplo: un polímero y una cerámica. Dentro de los polímeros naturales está el quitosano, cuyo precurson es la quitina, uno de los polímeros naturales más abundantes, que mejora la función del sistema inmune en animales, acelera la cicatrización y ha sido usado como material biocompatible y absorbible. Y dentro de las cerámicas está la hidroxiapatita, el mayor constituyente inorgánico del tejido óseo, que tiene buenas propiedades mecánicas y biocompatibilidad cuando es utilizada como material para implantes en dientes y hueso. No basta solo con un compósito para una regeneración ósea adecuada, la presencia de factores de crecimiento puede estimular a las células residentes como también a las células transplantadas. Entre los factores de crecimiento, se encuentra el factor de crecimiento derivado de plaquetas (PDGF) que es un potente mitogénico y quimiotáctico celular, este factor de crecimiento puede ser liberado localmente a través del uso de diferentes vehículos poliméricos que promueven un método controlado de liberación en un tiempo adecuado. Por lo tanto, es razonable proponer el uso de un compósito compuesto por quitosano e hidroxiapatita en una disposición multilaminar similar al tejido óseo, usando el factor de crecimiento derivado de plaquetas para aumentar la proliferación y diferenciación celular. En esta memoria de título se evaluó el efecto de la liberación controlada del factor de crecimiento derivado de plaquetas (PDGF-BB) desde un compósito de quitosano-hidroxiapatita multilaminar; y su efecto en la viabilidad, proliferación y diferenciación de los osteoblastos en cultivo. Para esto, se utilizo un kit ELISA con anticuerpos específicos para el factor de crecimiento PDGF-BB, también se uso el método MTT, prueba que cuantifica las células metabólicamente activas dentro del compósito. Como prueba de diferenciación se analizó la actividad de fosfatasa alcalina usando p-nitrofenilfosfato como sustrato, se analizó también la cantidad de calcio depositado con espectrofotometría de absorción atómica. Como pruebas cualitativas se realizó examen histológico de barrido. Los resultados mostraron que la liberación del factor de crecimiento PDGF-BB desde el compósito de quitosano-hidroxiapatita multilaminar al medio de cultivo, fue mayor los primeros días de cultivo disminuyendo paulatinamente hasta los últimos días del ensayo. La cantidad total acumulada liberada fue del 10% de la cantidad colocada inicialmente en el compósito, aún así ésta produjo su efecto aumentando la proliferación y diferenciación celular. Se observo un aumento en la proliferación osteoblástica bajo el efecto del factor de crecimiento PDGF-BB, mediante el uso de un método efectivo que midió la viabilidad y cantidad de osteoblastos dentro del compósito, demostrándose el efecto estimulador del factor de crecimiento incorporado al compósito. Claramente hubo un mayor depósito de calcio en los compósitos con factor de crecimiento, siendo una prueba indicativa de diferenciación celular. No se observó una diferencia significativa en la actividad de fosfatasa alcalina, debido posiblemente a las cantidades muy pequeñas de esta enzima en las muestras.se puede concluir que este compósito de quitosano-hidroxiapatita multilaminar enriquecido con el factor de crecimiento PDGF-BB y sembrado de células osteoblásticas, podría ser usado como implante para estimular la regeneración ósea / FONDECYT 1080185, FONDAP 11980002

Page generated in 0.4927 seconds