• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 178
  • 27
  • 26
  • 18
  • 15
  • 12
  • 11
  • 8
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 341
  • 341
  • 101
  • 76
  • 60
  • 55
  • 49
  • 48
  • 44
  • 44
  • 44
  • 44
  • 42
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Estudos de técnicas de feixes iônicos para a quantificação do elemento químico boro / Study of boron quantification using ion beam analysis techniques.

Marcos Vinicius Moro 16 May 2013 (has links)
Neste trabalho, estudamos e aplicamos técnicas analíticas com feixes iônicos para a identificação e quantificação do elemento químico Boro em amostras de Boro depositado sobre Níquel 11B/Ni, sobre Silício B/Si e em amostras de Silício Grau Metalúrgico - SiGM. Estas últimas foram fornecidas pelo grupo de metalurgia do Instituto de Pesquisas Tecnológicas (IPT). Especificamente, as seguintes técnicas analíticas foram utilizadas: Nuclear Reaction Analysis - NRA, Elastic Recoil Detection Analysis - ERDA e Secondary Ion Mass Spectrometry - SIMS. Nas amostras de B/Ni e B/Si, as concentrações foram obtidas com medidas de NRA, ERDA e SIMS. Também foi abordado quais dentre essas três técnicas apresentam menor limite de deteção e menor incerteza para a quantificação de Boro. Usando a reação nuclear 11B(p,a0)8Be, foi possível calcular a sua seção de choque diferencial para ângulo de espalhamento theta=170, cujo resultado, para este ângulo específico, é inédito na literatura. As amostras de SiGM foram analisadas com a técnica SIMS e comparadas com medidas de Inductively Coupled Plasma - ICP realizadas pelo grupo do IPT. Uma vez que técnicas nucleares podem ser consideradas absolutas, concluímos que as medidas de ICP apresentaram dados compatíveis com as medidas SIMS, e que o grupo de metalurgia do IPT está medindo as concentrações de Boro em suas amostras de SiGM corretamente por meio de ICP. Uma reta de calibração entre medidas SIMSxICP foi construída, que poderá servir como um guia para futuras quantificações de Boro com ICP feitas pelo grupo de metalurgia do IPT. / In this work we investigated the use of analytical techniques based on ion beams in the quantification of Boron in many kinds of samples. Specifically, we applied techniques such Nuclear Reaction Analysis (NRA), Elastic Recoil Detection Analysis (ERDA) and Secondary Ion Mass Spectrometry (SIMS) to 11B/Ni and B/Si samples to measure the boron concentration. We also discuss and show what technique has a better detection limit and lower uncertainty. For the first time in the literature, we obtained the cross section for the $^{11}B(p,\\alpha_0){^8}Be$ nuclear reaction in the energy range from 1.6 up to 2.0 MeV in theta = 170 scattering angle. The SIMS technique was applied to analise samples of metallurgical grade silicon (SiGM) from Metallurgy Group of Instituto de Pesquisas Tecnologicas (IPT) to check the Inductively Coupled Plasma (ICP) measurements carried out by the IPT. Moreover, it was possible to build a calibration curve between SIMS and ICP measurements, that can be used to help of Metallurgy Group with futures ICP\'s measurements.
312

‘Tri-3D’ electron microscopy tomography by FIB, SEM and TEM : Application to polymer nanocomposites / Tomographie électronique ‘Tri-3D’ en FIB, SEM et TEM : Application aux nanocomposites polymère

Liu, Yang 25 July 2013 (has links)
Ce travail a porté sur la caractérisation et la quantification en 3D de la répartition de charges de différents types (nanoparticules, nanotubes, etc.) dans des matrices polymères. Nous nous focalisons sur les techniques de tomographie en microscopie électronique. Une approche multiple en tomographie électronique a été réalisée : la tomographie en FIB/MEB (faisceau d’ions focalisé/microscope électronique à balayage), la tomographie en MEB et la tomographie en MET (microscope électronique en transmission). Les nanocomposites polymère sont généralement élaborés aux fins d’améliorer les propriétés physiques (mécanique, électrique, etc.) du matériau polymère constituant la matrice, grâce à une addition contrôlée de charges nanométriques. La caractérisation de tels matériaux, et l’établissement de corrélations précises entre la microstructure et les propriétés d’usage, requièrent une approche tri-dimensionnelle. En raison de la taille nanométrique des charges, la microscopie électronique est incontournable. Deux systèmes de nanocomposite polymère ont été étudiés par une approche multiple de tomographie électronique : P(BuA-stat-S)/MWNTs (copolymère statistique poly (styrène-co-acrylate de butyl) renforcé par des nanotubes de carbone multi-parois), et P(BuA-stat-MMA)/SiO2 (copolymère statistique poly(butyl acrylate-co-methyl methacrylate) renforcé par des nanoparticules de silice). Par combinaison de divers techniques, la caractérisation et la quantification des nanocharges ont été possibles. En particulier, la taille, la fraction volumique et la distribution des charges ont été mesurées. Cette étude a ainsi fourni des informations en 3D qui contribuent à mieux comprendre les propriétés des nanocomposites. Une attention particulière a été portée aux artefacts et causes d’erreur possibles durant l’étape de traitement 3D. Nous avons également essayé de comparer les différentes techniques utilisées du point de vue de leurs avantages et inconvénients respectifs, en dégageant des possibilités d’amélioration future. / This work is focused on the characterization and quantification of the 3D distribution of different types of fillers (nanoparticles, nanotubes, etc.) in polymer matrices. We have essentially used tomography techniques in electron microscopy. Multiple approaches to electron tomography were performed: FIB-SEM (focused ion beam/scanning electron microscope) tomography, SEM tomography and TEM (transmission electron microscope) tomography. Polymer nanocomposites are basically synthesized in order to improve the physical properties (mechanical, electric, etc.) of the pure polymer constituting the matrix, by a controlled addition of fillers at the nanoscale. The characterization of such materials and the establishment of accurate correlations between the microstructure and the modified properties require a three-dimensional approach. According to the nanometric size of the fillers, electron microscopy techniques are needed. Two systems of polymer nanocomposites have been studied by multiple electron tomography approaches: P(BuA-stat-S)/MWNTs (statistical copolymer poly(styrene-co-butyl acrylate) reinforced by multi-walled carbon nanotubes) and P(BuA-stat-MMA)/SiO2 (statistical copolymer poly(butyl acrylate-co-methyl methacrylate) reinforced by silica nanoparticles). By combining various techniques, the characterization and the quantification of nanofillers were possible. In particular, statistics about size, distribution and volume fraction of the fillers were measured. This study has then provided 3D information, which contributes to a better understanding of properties of the nanocomposites. Attention has been paid to analyze carefully original data, and artifacts and causes of errors or inaccuracy were considered in the 3D treatments. We also attempted to compare benefits and drawbacks of all techniques employed in this study, and perspectives for future improvements have been proposed.
313

Développement et applications de la tomographie chimique par spectroscopie EDX / Development and applications of chemical tomography by EDX spectroscopy

Lepinay, Kevin 27 November 2013 (has links)
Cette thèse porte sur l’évaluation des techniques pour la tomographie chimique par STEM EDX : mise au point des procédures expérimentales, traitement des données, reconstruction des volumes, analyse de la qualité des résultats obtenus et évaluation de la complexité globale. Les performances très limitées de l’analyse STEM EDX font que peu d’études, jusqu’à aujourd’hui, se sont portées sur cette technique. Cependant, les avancées très notables procurées par les nouveaux détecteurs ‘SDD’ ainsi que les sources électroniques X-FEG haute brillance, rendant l’analyse STEM EDX 2D très rapide, ont relancé la possibilité de la tomographie chimique ; la technique demande toutefois à être mise au point et évaluée (performances et complexité). Nous avons travaillé sur un microscope Tecnai Osiris permettant d’acquérir des cartographies chimiques EDX de centaines de milliers de pixels avec une résolution de l’ordre du nanomètre en quelques minutes. Nous avons choisi de préparer par FIB des échantillons en forme de pointe et d’utiliser un porte-objet permettant une exploration angulaire de 180° sans ombrage. Puis, à l’aide d’échantillons modèles (billes de SiO2 dans une résine), nous avons évalué les déformations d’échantillon par l’irradiation du faisceau électronique. Ceci nous a permis de proposer une méthode pour limiter cet effet par déposition d’une couche de 20 nm de chrome. Des simulations d’images ont permis d’évaluer les logiciels et méthodes de reconstruction. La méthodologie de chaque étape d’une analyse de tomographie STEM EDX a ensuite été expliquée, et l’intérêt de la technique démontré grâce à la comparaison de l’analyse 2D et 3D d’un transistor FDSOI 28 nm. La qualité des reconstructions (rapport signal-sur-bruit, résolution spatiale) a été évaluée en fonction des paramètres expérimentaux à l’aide de simulations et d’expériences. Une résolution de 4 nm est démontrée grâce à l’analyse d’une mire et d’un transistor « gate all around ». Pour ce même transistor, la possibilité et l’intérêt d’analyse de défaillance à l’échelle nanométrique est prouvée. Une analyse d’un défaut de grille d’une SRAM ou de trous dans un pilier en cuivre permettent d’expliquer l’intérêt d’une combinaison d’un volume HAADF (morphologie et résolution < 4 nm) et du volume EDX (information chimique). La conclusion est que cette technique, qui reste encore à améliorer du point de vue de sa simplicité, montre déjà son utilité pour l’analyse et la mise au point des technologies avancées (nœud 20 nm et après). / This thesis focuses on the evaluation of the STEM EDX chemical tomography technique: development of experimental procedures, data processing and volumes reconstruction, quality analysis of the results and evaluation of the overall complexity. Until now, STEM EDX analysis performances were very limited, so only few studies about this technique have been realized. However, very significant progress procured by the new SDD detectors as well as by the high brightness electronic sources (X-FEG), making the STEM EDX 2D analysis very fast, have revived the possibility of the chemical tomography, although the technique has to be developed and evaluated (performance and complexity). We have worked on a Tecnai Osiris which acquires EDX chemical mapping of hundreds of thousands of pixels with resolution of one nanometer and in a few minutes. We chose to prepare the rod-shaped samples by FIB and use a sample holder allowing an angle of exploration of 180° without shadowing effects. Then, using model samples (SiO2 balls in resin), we evaluated the sample deformation due to the electron beam irradiation. This allowed us to propose a method to reduce this effect by depositing a 20 nm chromium layer. Images simulations were used to evaluate the software and the reconstruction methods. The methodology of each step of the STEM EDX tomography analysis is then explained and the technique interest is demonstrated by comparing the 2D and the 3D analysis of a transistor 28 nm FDSOI. The quality of the reconstructions (signal-to-noise ratio, spatial resolution) was evaluated, in function of experimental parameters, using simulations and experiments. A resolution of 4 nm is demonstrated through the analysis of a test pattern and a "gate all around” transistor. For the same transistor, the possibility and the interest of a failure analysis at the nanoscale is proven. Analyses of a SRAM gate fail or of the holes in a copper pillar explain the benefits of a combination between a HAADF volume (morphology and resolution < 4 nm) and an EDX volume (chemical information). To conclude, this technique, which still needs to be improved in terms of simplicity, is already showing its usefulness for the analysis and the development of advanced technologies (20nm node and beyond).
314

Mikrostruktur und Wachstum bei der ionenstrahlunterstützten Deposition von Yttrium-stabilisierten Zirkonoxid-Filmen / Microstructure and growth of yttria-stabilized zirconia films fabricated by ion-beam-assisted deposition

Kautschor, Lars-Oliver 22 November 2002 (has links)
No description available.
315

Phase formation processes in the synthesis of boron nitride thin films / Phasenbildungsprozesse bei der Synthese von dünnen Filmen aus Bornitrid

Eyhusen, Sören 27 October 2005 (has links)
No description available.
316

Strukturbildung und Rauigkeiten an Grenzflächen des Ni-Ag-Legierungssystems / Structure Formation and Roughnesses at Interfaces of the Ni-Ag Alloy System

Petersen, Jan 21 April 2008 (has links)
No description available.
317

Swift heavy ion irradiation of semiconducting materials - defect production, phase transformation and annealing / Schwerionenbestrahlung von Halbleitermaterialien Defektakkumulation, Phasenumwandlung und Ausheilen

Nix, Anne-Katrin 02 July 2010 (has links)
No description available.
318

Ionenstrahlunterstütztes Wachstum von Zinn-dotierten Indiumoxid-Filmen / Ion beam assisted growth of tin-doped indium oxide films

Thiele, Karola 26 March 2004 (has links)
No description available.
319

Neuaufbau eines Pelletron-Beschleunigers und Untersuchungen zum Laserhydrieren von Silizium / Rebuild of a pelletron accelerator and investigations on laser hydriding of silicon

Schwickert, Marcus 29 October 2002 (has links)
No description available.
320

Multilagenbasierte Transmissionsoptiken für die Röntgenmikroskopie / Multilayer based transmission optics for x-ray microscopy

Liese, Tobias 15 May 2012 (has links)
No description available.

Page generated in 0.0432 seconds