Spelling suggestions: "subject:"komponenenter"" "subject:"bikomponenter""
41 |
Undersökning och täthetsmätning av små mekaniska komponenter.Leakage testing and analysis on small mechanical devicesDomfors, Ludvig, Andersson, Alexander January 2023 (has links)
The work was conducted at Saab Dynamics AB in Karlskoga, and the focus was to investigate and evaluate available methods for leak detection of small mechanical components, such as Electro-Explosive Devices (EEDs) and fuzes in warheads and using these methods to investigate whether they work for this purpose. At the start of the project, the problem was that these mechanical components were exposed to contamination, such as moisture and dust but also TNT exudate, plasticizers, gunpowder residues, etc. These contaminants may leak in or out of these components and may result inreduced performance and difficulties for the components to fulfill their function. The work was divided into two phases, with the first phase consisting of finding the best leak detection method available for the company that best suited the circumstances. The second phase of the work was to use the leak detection method evaluated in the first phase and to investigate its eligibility on the company's products and thereafter produce statistical data regarding the various products. The overall purpose of the project is to investigate and evaluate leak detection methods suitable to the company’s products, which may be used to ensure their quality.In phase one where leak detection methods were sought, it was discovered that different leak detection methods are suitable for different sizes of leaks. The search for a method was divided into two categories. A method for major leaks, gross leaks, as well as a method for smaller leaks, fine leaks. To assess which method was best suited for this purpose, standardized methods for product development, such as a decision matrix and a criteria matrix were used to objectively assess and screen appropriate solutions to the problem. The result of this study was that helium leak detection was the best method to analyze minor leaks and the bubble method was the best method for searching for gross leaks. Testing of these methods was done and the methods tested were helium leak detection and bubble test. The components tested were EEDs (<< 1 cc) and fuze holders (>1 cc). All types except one of the fuze holders met the leakage requirements that applied. The tightest component was specifically designed to be completely sealed. This has also been proven from four recuring aging tests conducted by the company. The second most sealed component could only complete one of the aging tests. The value that the completely sealed component got was then used as a recommended limit for leakage. The EEDs upheld a high level of tightness. One of the EEDs was designed to be tight, however the remaining types of EEDs met the same level of tightness. One possible reason for this result is that the internal volume of these detonators is too small to give a realistic and reliable results from these selected method. Because of this, more research should be carried out to find more suitable methods to measure small devices in the expected leakage interval. / Arbetet utfördes på Saab Dynamics AB i Karlskoga, där huvudfokus låg på att undersöka tillgängliga metoder för att läckagesöka små mekaniska komponenter, såsom elsprängkapslar och tändrör i stridsdelar och använda dessa metoder för att undersöka hur väl de fungerar på små mekaniska komponenter. Vid projektets påbörjan var problemet att dessa mekaniska komponenter blev utsatta för kontaminering, såsom fukt och damm men också TNT-exudat, mjukgörande, krutrester etc. Dessa kontamineringar tränger sedan in eller ut ur dessa komponenter och kommer att leda till sämre prestanda och svårigheter för komponenterna att uppfylla sin funktion. Arbetet delades upp i två faser, där den första fasen gick ut på att hitta den bästa läckagesökningsmetoden som fanns tillgänglig för företaget och som bäst passade de omständigheter som rådde. Den andra fasen i arbetet var att använda den läckagesökningsmetod som togs fram i första fasen för att undersöka dess lämplighet på företagets produkter samt ta fram statistiska data gällande läckage. Det övergripande syftet med arbetet är att undersöka lämpliga metoder för läckagesökning som kan appliceras på företagets produkter, med syfte att säkerställa kvalitén på dessa. I fas ett, där läckagesökningsmetod eftersöktes upptäcktes det att olika läckagesökningsmetoder lämpar sig till olika storlekar på läckage. Det beslutades att sökningen efter metod skulle delas upp. En metod för grövre läckage (gross leak) togs fram, samt en metod för mindre läckage (fine leak). För att bedöma vilken läckagesökningsmetod som var bäst lämpad för de olika komponenterna användes strukturerade metoder (kriterieviktsmatris och relativ beslutsmatris) för produktutveckling för att objektivt kunna bedöma och gallra lämpliga läckagesökningsmetoder att gå vidare med. Resultatet av detta var att heliumläckagesökning var den bästa metoden för att söka efter mindre läckor och bubbelmetoden var den bästa metoden för att söka efter större läckor. Testning av dessa metoder gjordes och de metoder som testades var heliumläckagesökning och bubbeltest. De komponenter som testades var små elsprängkapslar (<<1 cc) och större tändrör (>1 cc). Två olika prov gav olika nivåer på tätheten på fyra olika typer av tändrörsobjekt. Den tätaste är designad för att vara tillräckligt tät, vilket visats vid fyra olika åldringsprov. Den näst tätaste klarade bara 1 av 2 åldringsprov. Det värde som den täta komponenten fick användes som ett gränsvärde för att bedöma om tändrör är tillräckligt täta. Elsprängkapslarna uppfyllde en hög nivå på täthet. En av elsprängkapslarna är designad för att vara tät, vilket den var, men resterande typer uppfyllde samma nivå av täthet som den gjorde. En möjlig anledning till detta resultat är att den interna volymen i dessa elsprängkapslar är för liten för att kunna ge ett realistiskt och pålitligt resultat med de provade täthetsmätningsmetoderna. Därför bör det undersökas i vidare arbete om mer lämpliga täthetsmätningsmetoder kan hittas för dessa små komponenter i det förväntade läckageintervallet.
|
42 |
Automated Testing of Digital ComponentsKabiri, Babak January 2020 (has links)
In today's technological companies digital electronics and components are abundant. Many companies use these components to manufacture a wide variety of electronic products such as computers, tv’s, cars, etc. But after their use, these components are thrown away easily and are an additional contributor to our growing climate change. There is a need for a more effective way to deal with these components. Companies could save a lot of time and energy to have a system that could test these components.The goal of this study is to present a suitable method for testing digital components by developing a test program for testing the various integrated circuits and thus identifies which circuits are faulty and which ones are not. The economical and efficiency side of building such a program is discussed and If it is worth the time to produce such a system, or if it's much better to throw the components away. The intent is also to give companies a way of being more efficient and environmentally friendly.This program was made by using integrated circuits from the course IE1204 and IE1205, where students use these components for their labs. After the course has ended there is no certainty if the integrated circuits work properly or not. The goal of the program is then to test them and find out the faulty ones.An Arduino Uno and the Arduino programming language have been used to write the code for this project. The Arduino Uno was connected to a breadboard which then ran the program for testing. To that breadboard, various integrated circuits, such as logic gates, were connected. The Arduino program then tested their truth tables to see if they worked properly or not.Because of time restriction more complex components have not been included in this thesis. / I dagens tekniska industri finns det rikligt med digitala komponenter och elektronik. Många av dessa komponenter används för att bygga större elektronik såsom datorer, tv apparater, bilar, etc. Men efter deras användning slängs dessa komponenter tveklöst och är dessutom en orsakande faktor i vår växande klimatförändring. Det finns ett behov av en mer effektiv lösning för hanteringen av dessa komponenter. Företag kan spara mycket tid och energi med att inneha ett sådant system.Målet med detta projekt är att presentera en metod för att testa digitala komponenter. Att utveckla ett system som kan testa diverse integrerade kretsar och veta vilken som fungerar adekvat. Utvecklandet av ett sådant systemet ur ett ekonomisk och effektivitetsperspektiv diskuteras. Om det är värt att utveckla ett sådant system, eller om det är mycket bättre att bara slänga dessa komponenter. Målet med detta projekt är också att bana väg för företag att bli mer effektiva och miljövänliga.Tillvägagångssättet kring hur detta system har utvecklats är genom att använda integrerade kretsar från kurserna IE1204 och IE1205, där studenter använder dessa komponenter för deras labbar. Efter att kursens avslut finns det ingen garanti ifall dessa integrerade kretsar fungerar eller inte. Målet med programmet är då att testa dessa och hitta de trasiga komponenterna.En Arduino Uno och programmet Arduino har använts för att skriva koden till detta projekt. Arduinon har varit kopplad till en breadboard som har kört programmet för testing. Till denna breadboard har diverse integrerade kretsar, logiska grindar, varit kopplade.Arduino programmet har sedan testat de olika sanningstabellerna för att testa vilken logisk grind som är kopplad och fungerar.På grund av tidsbegränsning har mer komplexa integrerade kretsar blivit presenterade som en beskrivning av hur man kan fortsätta arbetet för att programmet skall inkludera mer komplexa komponenter.
|
43 |
Långsiktig underhållsplan / Long-term maintenance planCumbo, Aleksandar, Mahmod, Mokarrm January 2021 (has links)
AstraZenecas PET BFS på site Snäckviken vill implementera en maskinstatuslista lik den som implementerats för PET TBH/PS, för att kunna få en överblick över hela området samt kartlägga och prioritera framtida investeringar och besluttagande. PET BFS (IN/PP) är i behov av en maskinstatuslista på grund av en del föråldrad utrustning, inhalation och injektion linjerna saknar utförligt underlag för att en investeringsplan ska tas fram. Syftet med skapandet utav maskinstatuslistan är för att kunna ta reda på om livslängden kan förlängas eller om och när utrusningen behöver renoveras, uppgraderas eller bytas ut. Målet med rapporten är att sammanställa en maskinstatuslista/kritikalitetsmatris över all utrustning inom PET BFS, vilket inkluderar både inhalation och injektion. Maskinstatuslistan ska innehålla nuläget på status för utrustning. Detta inkluderar livslängd, reservdelsstatus och underhållskostnader för respektive utrustning. Det ska hjälpa PET BFS med att skapa en helhetsbild över linje/område vilket innebär att säkerhetsställa driftsäkerheten för all utrustning, identifiera kritiska komponenter, ta fram investeringsunderlag samt tillföra samsyn för underhållsstrategin inom verksamheten. Listan ska vara möjlig för fortsatt uppdatering av underhållsingenjör/serviceingenjör samt deltagare/resurser. De kritiska komponenterna identifierades för IN06, IN07, IN08, PO06, PO07 samt listades i maskinstatuslistan. De kritiska komponenternas status identifierades genom kontakt med leverantörer. Riskanalysen kunde inte utföras fullt ut dels på grund av saknad information, saknad tillgång till SAP samt tidsbegränsning. Data för andelen utgångna komponenter visar att en stor andel av komponenterna som undersökts är utgångna, samtidigt som majoriteten av dessa utgångna komponenter har ersättare. / AstraZeneca's PET BFS on the site Snäckviken wants to implement a machine status list similar to the one implemented for PET TBH / PS in order to get an overview of the entire area to map and prioritize future investments and decisions. PET BFS (IN/PP) is in need of a machine status list due to some outdated equipment, inhalation and injection departments lacking a detailed basis for producing an investment plan. The purpose of creating the machine status list is to be able to find out if the service life can be extended or if and when the equipment needs to be renovated, upgraded, or replaced. The aim of the report is to compile a machine status list/criticality matrix of all equipment within PET BFS, which includes both inhalation and injection. The machine status list must contain the current status of equipment status. This includes service life, spare part status and maintenance costs for each piece of equipment. It will help PET BFS to create an overall picture of the line/area, which means ensuring the operational safety of all equipment, identifying critical components, producing investment data and adding consensus for the maintenance strategy within the business. The list must be possible for further updating of the maintenance engineer/service engineer and participants/resources. The critical components were identified for IN06, IN07, IN08, PO06, PO07 and listed in the machine status list. The status of the critical components was identified through contact with suppliers. The risk analysis could not be performed in full due to lack of information, no access to SAP and time constraints. Data for the proportion of obsolete components show that a large proportion of the components examined are obsolete, while the majority of these obsolete components have a replacement.
|
44 |
Streamlining of Hydraulic Testing / Effektivisering av Hydraulisk ProvningHardell, Henrik, Lind, Niclas January 2012 (has links)
ST Aerospace located at Arlanda airport maintain and repair aircraft components. The maintenance activities that the workshop conducts require testing of the component’s function. For a long time the repair shop has experienced problems with the efficiency in this hydraulic testing. The efficiency problems are partially derived by the fact that the manufacturer’s component maintenance manuals (CMM) are not adapted to the specific test equipment that the shop uses. A lack of suitable training material also causes problems for new operators. The purpose of this thesis work was therefore to streamline this part of ST Aerospace’s operation, first by rewriting the test section of the manuals but also to produce a basic description of the test bench that is used in the testing activities. By studying the operator’s work with component testing a fundamental understanding of the test bench was obtained along with the specific knowledge that was required in order to rewrite the manuals to a version that ST can use with their specific test equipment. Along with the training material a total of four rewritten component manuals were produced on ST’s behalf. Since the purpose of this work was to streamline the company’s entire testing business, there are post-doubts about whether the correct way to address the issue was chosen. As the work continued it became increasingly more obvious that a more appropriate way of handling the efficiency problems should have been to fully focus on the training material for the test bench. By performing the work this way around the future rewriting of the hundreds of component manuals can be drastically simplified and more efficient, therefore the time required for rewriting can be drastically reduced. / ST Aerospace på Arlanda underhåller och reparerar flygplanskomponenter. I de underhållsåtgärder som verkstaden bedriver krävs testning av komponenternas funktion. Under en lång tid har verkstaden upplevt problem med effektiviteten i denna hydrauliska provning. Problemen med effektiviteten härstammar till viss del av att komponenttillverkarens testningsmanualer inte är anpassade till den specifika testutrustning som verkstaden använder sig av. Problemen härstammar också till viss del av att verkstaden haft problem med att utbilda nya operatörer av testutrustningen då lättförståeligt utbildningsmaterial till den avancerade utrustningen saknats. Syftet med detta examensarbete var därför att effektivisera denna del av ST Aerospace:s verksamhet genom att dels skriva om manualers testavsnitt men även att tillverka en lättförståelig beskrivning av verkstadens testutrustning i utbildningssyfte. Genom att följa operatörerna i deras arbete med av företaget utvalda komponenttester kunde en grundläggande förståelse både för testbänken men även för de utvalda testerna erhållas. Erfarenheten från testningen användes till att producera en lättförståelig beskrivning av provbänken samt till omskrivning av de utvalda komponentmanualerna. Utöver utbildningsmaterialet producerades totalt fyra omskrivna komponentmanualer för ST:s räkning. Då syftet med arbetet var att effektivisera hela ST:s provningsverksamhet är det i efterhand tveksamt till om angripningssättet av effektiviseringsproblemen varit rätt. Alltefter arbetets gång insågs i ökande grad att ett mer lämpligt angripningssätt hade varit att lägga all arbetstid på utbildningsmaterialet till provbänken för att på så sätt förenkla de framtida omskrivningarna av komponentmanualer. Ett mer utförligt utbildningsmaterial till testutrustningen kan effektivisera produceringen av omskrivna komponentmanualer betydligt då företaget i dagsläget testar hundratals komponenter.
|
45 |
Analys av PWM-mönster i Matlab / Analysis of PWM patterns in MatlabMilevski, Mikael January 2002 (has links)
<p>One of ABB Power Systems´s business areas is HVDC (High Voltage Direct Current) technology. HVDC is used for transmissions for both short and long distances. One of Power Systems’s products is called HVDC Light. </p><p>HVDC Light is a relatively new technology for power transmission, but have before only been used for motor drives applications. The technology is based on VSC (Voltage Source Converter) that uses a technique called PWM (Pulse Width Modulation). </p><p>There are a lot of PWM patterns that have been examined, but not in the field of power transmission where ABB Power Systems is working. </p><p>The different PWM patterns can be used for reducing switching losses or harmonics, that can cause the need of external filters to decrease or increase. </p><p>The purpose of this report is to give a general picture of the system that generates the PWM patterns. The report describes some main components in the system. T</p><p>he thesis also present amplitude spectrum from various PWM patterns - generated by signals that have been pulse width modulated with a triangle- shaped wave. </p><p>By showing the frequency-content, the decisions are eased for the engineers and technicians that are working with this kind of questions. </p><p>An analysis of different PWM patterns have been done. The kind of reference waves that generate the PWM patterns are called Dead Band PWM and Modified SPWM. </p><p>Comparisons have been done for Dead Band PWM, between harmonics and the width of Dead Band. Comparisons have been done for Modified SPWM, between: </p><p>1. fundamental frequency and modulation index. </p><p>2. different Modified SPWM and their harmonics.</p>
|
46 |
Jordfelssimulering och modell-validering med PSCAD av ett impedansjordat distributionsnät / Ground fault simulation and model validation with PSCAD of an impedance grounded distribution systemHällsten, Christoffer January 2015 (has links)
Detta examensarbete har utförts hos Vattenfall Eldistribution på avdelningen Kontroll och Skydd med målsättningen att utforma och utvärdera en nätmodell avsedd för jordslutningssimuleringar i PSCAD. Ombyggnationen från luftledningar till markkablar har medfört att kapacitansen i distributionsnätet ökat, vilket ställer högre krav på jordfelsutrustning och på nätanalyser för att kunna försäkra att en säkerställd frånkoppling kan ske enligt de myndighetskrav som föreligger. Syftet med arbetet har varit att undersöka hur en nätmodell bör utformas för analys av stationära in-svängningsförlopp och utvärdera hur stor noggrannhet som kan förväntas gentemot verkliga jordfelsprov vid felresistanser på främst 3 kΩ och 5 kΩ. Nätmodellen har ut-formats efter ett verkligt impedansjordat mellanspänningsnät med π-länkar i PSCAD och utifrån de nätuppgifter som förekommer i Vattenfalls näthanteringsprogram Netbas. Simuleringsresultaten har jämförts mot resultat från det verkliga nätets jord-felsprover vid olika inställningar på den centrala kompenseringsutrustningen som är placerad mellan den matande transformatorns nollpunkt och jord. Jordslutningssimuleringarna visar, trots antaganden och en viss osäkerhet omkring de verkliga nollföljdskomponenterna, godtyckliga simuleringsresultat vid avstämt och snedavstämt nät motsvarande ± 30 A gentemot ledningarnas kapacitiva strömmar vid en felresistans på 3 kΩ. Jordslutningssimuleringarnas händelseförlopp överensstäm-mer överlag väl mot det verkliga nätet samtidigt som jordslutningar vid 5 kΩ medför en större procentuell avvikelse. Särskilt framträdande avvikelser kunde urskiljas vid analys av fasvinkeln mellan nollföljdsspänning och nollföljdsström. En analys av nätmodellens resultat och troliga orsaker till uppkomna simulerings-avvikelser gentemot det verkliga nätet indikerar på att nätmodellens tillförlitlighet bör kunna optimeras ytterligare om noggrannare hänsyn tas gällande nollföljdsimpedanser, dc-komponenter och de toleranser som förekommer i det verkliga nätets avstäm-ningsutrustning och mätkretsar. / This thesis has been carried out at Vattenfall Eldistribution at the department Control and Protection with the objective to design and evaluate a network model for ground fault simulations in PSCAD. The reconversion from overhead lines to underground cables has led to increased capacitances in the distribution network and this places greater demands on the feeder protection unit and network analyzes in order to assure that faulted feeders are disconnected according to regulatory requirements. The aim of this work has been to determine how a network model could be designed for analysis of stationary signal characteristics and evaluate how great accuracy the power system model have compared to real earth fault test results. Earth fault simulations are performed with fault resistances of 3 kΩ and 5 kΩ. The power system model have been created to emulate a real impedance grounded network according to the π-model in PSCAD based on system information from Vattenfalls network management program Netbas. Results from the simulations have been compared against results obtained from real earth faults from the physical network with different settings on the central compensation equipment placed between the transformers neutral and ground. Simulations show, despite assumptions and some uncertainty about the actual zero sequence components similar results when fault resistance was 3 kΩ, both when compensation coil are fully tuned and out of tune ± 30 A corresponding to the feeder capacitance. The overall signal sequence conform quite well to the real network but at the same time simulations with 5 kΩ obtains greater deviations when results are represented in percentage. Particularly prominent abnormalities could be identified in the phase angle between zero sequence voltage and zero sequence current. An analysis of deviations from the simulations in the digital network model against the real system indicates that the model probably could be further optimized if zero sequence impedances, dc components, and tolerances that occur in the real systems reactive compensation equipment and measuring circuits are taken into account.
|
47 |
Analys av PWM-mönster i Matlab / Analysis of PWM patterns in MatlabMilevski, Mikael January 2002 (has links)
One of ABB Power Systems´s business areas is HVDC (High Voltage Direct Current) technology. HVDC is used for transmissions for both short and long distances. One of Power Systems’s products is called HVDC Light. HVDC Light is a relatively new technology for power transmission, but have before only been used for motor drives applications. The technology is based on VSC (Voltage Source Converter) that uses a technique called PWM (Pulse Width Modulation). There are a lot of PWM patterns that have been examined, but not in the field of power transmission where ABB Power Systems is working. The different PWM patterns can be used for reducing switching losses or harmonics, that can cause the need of external filters to decrease or increase. The purpose of this report is to give a general picture of the system that generates the PWM patterns. The report describes some main components in the system. T he thesis also present amplitude spectrum from various PWM patterns - generated by signals that have been pulse width modulated with a triangle- shaped wave. By showing the frequency-content, the decisions are eased for the engineers and technicians that are working with this kind of questions. An analysis of different PWM patterns have been done. The kind of reference waves that generate the PWM patterns are called Dead Band PWM and Modified SPWM. Comparisons have been done for Dead Band PWM, between harmonics and the width of Dead Band. Comparisons have been done for Modified SPWM, between: 1. fundamental frequency and modulation index. 2. different Modified SPWM and their harmonics.
|
48 |
BUILDING AND SIMULATING DYNAMIC MODELS OF DISTRICT HEATING NETWORKS WITH MODELICA : Using Matlab to process data and automate modelling and simulationKos, Cristoffer, Hermansson, Kristoffer January 2017 (has links)
District heating systems are common in Nordic countries today and accounts for a great portion of the heat demand. In Sweden, total district heating end use in the last years has been around 50 TWh and district heating accounts for roughly 50 % of the total heat demand. Suppliers of district heating must balance demand and supply, often in large and complex networks. Heat propagation can be in the range of hours and it is not known in detail how the heat will propagate during transient conditions. A dynamic model has been developed in OpenModelica and a method for modeling, handling data, simulating and visualizing the results of a district heating network was developed using Matlab as core. Data from Mälarenergi AB, a district heating producer and grid operator, was used for validation of the model. Validation shows that the model works well in predicting heat propagation and temperature distribution in the network and that the model can be scaled up to a large number of heat exchangers and pipes. The model is robust and can handle bi-directional and reversing flows in complex ring structures. It was concluded that OpenModelica together with Matlab is a good combination for creating models of district heating networks, as a high degree of standardization and automation can be achieved. This, together with visualization of the heat propagation, makes it useful for the understanding of the district heating network during transient conditions. / Smarta Flöden
|
49 |
Centrala komponenter i omvårdnaden av pediatriska traumapatienter på en akutmottagning : En litteraturstudie / Key components in the nursing care of pediatric trauma patients at an emergency department : A literature reviewLarsson, Martina, Strand, Viktoria January 2020 (has links)
Bakgrund: Pediatriskt trauma är ett internationellt hälsoproblem som kräver att sjuksköterskan har ökad kunskap om barnets och dennes familjs behov, hur barnet reagerar på trauma både psykologiskt och fysiologiskt samt speciella färdigheter för att ge traumavård av god kvalitet. Att ge omvårdnad till dessa patienter kan vara komplext för sjuksköterskan, då vanligtvis även familjen finns närvarande. Syfte: Att undersöka centrala komponenter i omvårdnaden av pediatriska traumapatienter på en akutmottagning. Metod: En litteraturstudie med systematisk datainsamling och analys och kvalitativ metod genomfördes med sökningar ur två databaser. Befintliga data ur vetenskapliga artiklar har granskats och analyserats. Elva kvalitetsgranskade primära studier identifierades till resultatet. Resultat: Tre huvudkategorier analyserades fram. Den första kategorin är Förmedla trygghet. Att ge löpande information, vara stödjande och lugnande med empati och skapa en förtroenderelation var viktigt för att förmedla trygghet. Samspel och stöd var den andra kategorin och det mest framträdande resultatet som tar upp samspelet mellan sjuksköterska, patient och dennes familj. Vid omvårdnad av pediatriska traumapatienter är det inte bara barnet i sig som behöver uppmärksammas, sjuksköterskan behövde se hela familjen och ge stöd, bjuda in till delaktighet och smärtlindra både psykologiskt och fysiologiskt. Organisatoriska förutsättningar är den tredje kategorin som beskriver hur sjuksköterskans kompetens har betydelse för omvårdnadens kvalitet, vilken påverkan tid har och hur sjuksköterskan i sitt samarbete med kollegor kan ge god omvårdnad. Slutsats: Det finns flera komponenter i omvårdnaden av pediatriska traumapatienter och dessa patienter får olika förutsättningar beroende på vilken akutmottagning som tar emot och vilken kompetens som finns på plats. Sjuksköterskan befinner sig i en komplex och stressfylld situation där många olika behov måste tillgodoses. Sjuksköterskans kompetens behöver därför utvecklas kontinuerligt för att skapa trygghet och kunskap om vilka behov som är viktigast att prioritera. / Background: Pediatric trauma is an international health problem which requires that the nurse has increased knowledge of the needs of the child and their family, the child’s response to trauma both psychologically and physiologically, as well as special skills to provide trauma care of good quality. Providing nursing care to these patients can be complex for the nurse, as usually the patient’s family is present. Aim: The aim of this study was to investigate the key components in the nursing care of pediatric trauma patients in an emergency department. Method: A literature study with systematic data collection and analysis with qualitative method was conducted with searches from two databases. Existing data from scientific articles have been reviewed and analyzed. Eleven quality-reviewed primary studies were identified as the result. Results: Three main categories were presented. The first category was to convey safety. Providing ongoing information, being supportive and reassuring with empathy and creating a relationship of trust were important in conveying safety. Interaction and support were the second category and the most dominant, which addressed the interaction between the nurse, the patient and the patient’s family. In the nursing care of pediatric trauma patients, it is not only the child itself that needs attention, but the nurse needed to view the whole family and provide support, invite them to participate and relieve the pain both the psychological and the physical. Organizational conditions were the next category, which described how the nurses skills are important for the quality of nursing care, the impact of time and how the nurse with collaboration with their colleagues, can provide good nursing care. Conclusions: There are several components in the nursing care of pediatric trauma patients and these patients have different prerequisites, depending on which emergency department receives them and the expertise that exists in place. The nurse is in a complex and stressful situation, where many different needs must be met. The nurse’s competence, therefore, needs to be developed constantly, in order to provide security and knowledge of the needs that are most important to prioritize.
|
50 |
Lagerhantering och Automated Storage and Retrieval System (AS/RS) : En flerfallstudie om Automated Storage and Retrieval systems för- och nackdelar för en kostnadseffektiv lagerhanteringAnton, Lindh January 2020 (has links)
Titel: Lagerhantering och Automated Storage and Retrieval System (AS/RS) – En flerfallstudie om Automated Storage and Retrieval systems för- och nackdelar för en kostnadseffektiv lagerhantering Kurs: Examensarbete i Controller för Civilekonomprogrammet, 30 hp (4FE18E) Lärosäte: Ekonomihögskolan vid Linnéuniversitetet i Växjö Författare: Anton Lindh Inledning: Lagerverksamheten har fått en ökad betydelse för företags framgång. Designen på moderna lager har en stor påverkan på investering- och driftkostnad. Vidare sätter e-handelns ökning samt kunders krav press på lagerverksamheter i form av ökat behov av lagerutrymme, behov av alternativ för att hålla nere höga personalkostnader samt snabba leveranser. Automated Storage and Retrieval systems (AS/RS) är ett automatiserat lagersystem som ökar stadigt i användning hos stora företag. I uppsatsen görs försök att undersöka hur för- och nackdelarna påverkar kostnadseffektiviteten av lagerhanteringen och lagerverksamheten. Även huvudtyperna av AS/R system samt AS/R systemets komponenter undersöks för att ge en möjlig förklaring till hur dessa påverkar utfallet av systemets kostnadseffektivitet Syfte: Syftet med uppsatsen är att kartlägga de för- och nackdelar som AS/R system bidrar till lagerhanteringen samt hur för- och nackdelarna kan påverka hur kostnadseffektiv lagerhantering blir. En del av syftet med att besvara fråga 1 och 2 är att kunna vidare djupdyka i och analysera de olika typer och komponenter ett AS/RS består av och se hur dem specifikt kan bidra till slutsatserna av fråga 2. Besvarandet av frågorna ska bidra till ökadförståelse om hur AS/RS på olika sätt kan hjälpa (eller stjälpa) lagerverksamheten och lagerhanteringen att bli mer kostnadseffektiv hos företagMetod: I uppsatsen har en flerfallstudie genomförts med 3 företag som tillsammans har 4 AS/R system. Den empiriska materialinsamlingen skedde genom semistrukturerade intervjuer. Slutsats: Slutsatserna belyser flera för- och nackdelar. Framstående slutsatser inkluderar nackdelar såsom att AS/R system har höga initiala investeringskostnader samt flera flexibilitetsproblem som kan hindra en kostnadseffektiv lagerhantering. Å andra sidan har flera fördelar belysts såsom hög genomströmningskapacitet på grund av underlättande av rutiner och högre produktivitet tillsammans med lägre personalkostnader och minskad ytanvändning. Två analytiska modeller är även presenterade för slutsatserna kring AS/R systemens huvudtyper samt komponenter och deras påverkan på en kostnadseffektiv lagerhantering.
|
Page generated in 0.1084 seconds