• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 400
  • 79
  • 38
  • 32
  • 21
  • 19
  • 12
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 752
  • 87
  • 80
  • 78
  • 77
  • 72
  • 65
  • 58
  • 50
  • 47
  • 46
  • 45
  • 40
  • 39
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Efeitos fototérmicos em filmes ultrafinos / Photothermal effects on ultrathin films

Tiago dos Santos Rodrigues 06 February 2007 (has links)
Nesta dissertação são estudados três sistemas interfaciais, com o objetivo de observar o efeito do aquecimento localizado por laser. O primeiro sistema consistiu de filmes ultrafinos de níquel ftalocianina tetrasulfonada, com intercalantes diferentes (Zr e PDDA), analisados pela técnica fototérmica de lente térmica (LT). Foi montada uma instrumentação de LT completa, sendo a fonte excitante um laser de He-Ne de baixa potência (10 mW). Estes filmes, com diferentes números de camadas, foram imersos em solventes orgânicos e a transferência de calor na interface foi estudada através do ajuste do sinal de LT. Os dados obtidos revelaram a proporcionalidade do sinal de LT com o aumento do número de camadas e permitiram a determinação das difusividades térmicas dos solventes utilizados. O segundo sistema consistiu de monocamadas de hexadecanol depositadas na superfície de soluções de cristal violeta (CV). A superfície destas soluções foi aquecida a laser e a transferência do calor gerado foi detectada através de uma instrumentação de deflexão fototérmica transversa (PDB). Estes experimentos foram realizados em uma balança de superfície, com uma compressão controlada da mono camada. Foi observado um aumento da transferência de calor para o ar a partir de um certo ponto da isoterma de compressão da monocamada. O mecanismo de supressão de correntes de convecção por surfatantes é indicado como provável causador deste aumento de transferência de calor. O terceiro sistema consistiu na fabricação de filmes LB de ácido octadecanóico modificados pelo aquecimento do menisco durante a sua deposição. Uma instrumentação semelhante a empregada no segundo experimento serviu de base para estes experimentos, com o laser de excitação direcionado próximo ao substrato. Foram observadas as curvas de taxa de transferência e foram comparadas as morfologias do filme resultante deste aquecimento com filmes não aquecidos do ácido octadecanóico e do ácido octadecanóico na presença de Orange G (OG), o corante empregado para geração de calor. Nestes estudos morfológicos são apresentadas microscopia ópticas do filme, que mostram a formação de anéis no filme, provavelmente devido à evaporação da subfase. São também apresentadas imagens de microscopia de força atômica deste filme submetido a aquecimento, evidenciando o enrugamento da superfície em nível micrométrico, mostrando ser possível modificar o processo de formação de filmes através do aquecimento localizado. / In this dissertation three interfacial systems were examined, with the goal of observing the effect of localized laser-heating on them. The first studied system were ultrathin films of nickel tetrasulfophthalocyanine, with different compounds (Zr or PDDA), analyzed by thermal lens. A complete instrumentation of LT was mounted, being the exciting source a He-Ne laser of low power (10 mW) and low cost. These films, with different numbers of layers, had been immersed in organic solvents and the heat transfer through the interface was studied through mathematical fitting of the LT signal. The acquired data had disclosed the proportionality of the signal of LT with the increase in the number of layers and had allowed the determination of thermal diffusivities of the used solvents. Hexadecanol monolayers on the surface of Crystal Violet (CV) aqueous solutions were the second system to be studied. The surface of these solutions was laser-heated and the heat transfer to the air was detected through a photothermal beam deflection instrumentation (PDB). These experiments have been carried out in a surface balance to provide controlled compression of the monolayer. An increase in the heat transfer to the air from a certain point of the monolayer isotherm was observed. The mechanism of suppression of surface tension-induced convection by surfactants is proposed as the probable cause of such increase. LB films of octadecanoic acid were used in the third set of experiments, with the aim of modifying the film surface morphology by laser heating of the meniscus region during the deposition process. An instrumentation similar to the one employed in the previous experiment served as base for these experiments, with the laser of excitement pointed close to the substrate. The curves of transfer ratio had been observed and the morphologies of the laser-heated ?lm were compared to the non-heated films of octadecanoic acid with and without Orange G (OG, dye used as auxiliary for heat generation). Optical microscopy images from the laser-heated film were obtained, showing ring formation, probably due the evaporation of subphase. Also images of atomic force microscopy of this laser-heated film are shown, evidencing the wrinkling of the surface in micrometric level when compared to similar films from non-heated films. This behaviour shows the feasibility of modification in the process of formation of LB films through localised laser-heating.
382

Desempenho visual dos pacientes pseudofácicos com diferentes lentes intraoculares / Visual performance of pseudopahkic patient with different intraocular lenses

Wilson Takashi Hida 17 May 2013 (has links)
Objetivos: Comparar a performance visual dos pacientes submetidos ao implante das lentes intraoculares multifocais difrativas Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60WF e Acrysof® SN60AT. Métodos: Estudo prospectivo comparativo, não randomizado, que incluiu 142 olhos de 71 pacientes com catarata, provenientes do ambulatório de oftalmologia do HC- FMUSP. A avaliação oftalmológica contou com medida da acuidade visual para longa, intermediária e curta distância, sem correção e com a melhor correção óptica, teste de sensibilidade ao contraste, pupilometria e análise de frente de onda por meio do aberrômetro. Um questionário de satisfação foi realizado para avaliar a acuidade visual, glare e halos. Todos os exames foram realizados com seis meses de pós-operatório. Resultados: A média de idade dos pacientes foi de 60,7 ± 6,6 anos no grupo Tecnis, 63,1 ± 4,4 anos no grupo Restor e 63,7 ± 4,2 anos no grupo monofocal (SN60AT no olho contralateral SN60WF). A acuidade visual para perto não corrigida e corrigida para longe foi estatisticamente superior nos grupos multifocal Restor e multifocal Tecnis em comparação ao grupo monofocal SN60AT/SN60WF (p<0,001). Não houve diferença estatística entre os grupos na comparação da acuidade visual para longe (p=0,56). A sensibilidade ao contraste fotópica monocular foi estatisticamente inferior nos grupos Restor e Tecnis (p<0,001). A SN60AT apresentou maior aberração esférica comparada a todas as outras lentes (p<0,001). A Tecnis se mostrou com menores valores médios de aberrações esféricas na comparação com a Restor (p<0.001). O questionário de satisfação apresentou maior independência de óculos a favor da Tecnis e Restor, mas com mais queixas de halos e glare do que no grupo monofocal SN60AT/SN60WF. Conclusão: A Restor e Tecnis apresentaram melhor acuidade visual para perto do que o grupo monofocal SN60AT/SN60WF. Todas as lentes intraoculares promoveram boa visão para longe. O grupo da Tecnis apresentou melhor sensibilidade de contraste, menos aberrações óptica e melhor visão intermediária que o grupo Restor. As lentes Restor e Tecnis apresentaram maior satisfação na visão de perto e independência do uso de óculos e glare e halos do que as lentes monofocais / Purpose: Comparison of the visual performance between patients with Tecnis® MF ZM900, Acrysof® Restor® SN60D3, Acrysof® SN60AT and Acrysof® SN60WF intraocular lenses. Patients and methods: This prospective comparative study included 142 eyes of 71 patients in Sao Paulo University. The ophthalmologic evaluation performed included near, intermediate and distance corrected and uncorrected visual acuity, contrast sensitivity measurement and wavefront analysis. All patient underwent a quality of life questionnaire related to visual acuity, glare and halos. The minimum follow-up was 6 months. Results: The mean age of patients was 60.7 ± 6.6 years in the Tecnis® MF, 63.1 ± 4.4 years in-group Restor® 63.7 ± 4.2 years in monofocal group (SN60AT in the fellow eye SN60WF). The Restor and Tecnis groups has uncorrected near and corrected distance visual acuity statistically superior compared to SN60AT/SN60WF group (p <0.001). There was no statistical difference between groups when compared uncorrected and best-corrected distance visual acuity (p = 0.56). Contrast sensitivity in photopic conditions was significantly lower in the Restor and Tecnis group (p <0.001). The SN60AT showed higher spherical aberration compared to all other lenses (p <0.001). The Tecnis showed a lower mean values of spherical aberration compared to Restor lenses (p <0.001). Quality of life questionnaire showed greater independence from glasses for the Tecnis and Restor groups, but with more complaints of halos and glare than the monofocal SN60AT/SN60WF group. Conclusion: Restor and the Tecnis had better near visual acuity than the SN60AT/SN60WF group. All intraocular lenses promoted good distance vision. The Tecnis group showed better contrast sensitivity, less aberrations and better intermediate vision than the Restor group. Restor and Tecnis lenses showed higher satisfaction with near vision and independence from glasses, glare and halos than the monofocal lens
383

Caracterização termo-óptica de materiais lasers usando a técnica de lente térmica / Thermo-optical charecterization of lasers material using the thermal lens tecnique

Carlos Jacinto da Silva 17 February 2006 (has links)
Neste trabalho investigamos as propriedades térmicas (difusividade, condutividade, variação do caminho óptico com a temperatura, etc) e processos de perdas devido a interações entre íons em materiais lasers vítreos e cristalinos. Desde que a eficiência quântica de fluorescência, , está diretamente relacionada com esses mecanismos que levam a supressão da luminescência, os estudos foram realizados principalmente observando os efeitos desses agentes sobre . Espectros de lente térmica (LT) foram usados para determinar , eficiência de transferência de energia matriz-íon, e para analisar efeitos de sítios de defeitos sobre . Um novo método usando a técnica de LT foi proposto para determinar e o coeficiente de temperatura do caminho óptico. Com esta nova abordagem analisamos em materiais vítreos os mecanismos de supressão da luminescência em função da concentração de íons de Nd. Também a usamos para estudar efeitos de radicais de OH e outras impurezas em matrizes vítreas de fosfato dopadas com Yb3+. Processos de conversão ascendente Auger, os quais são importantes em sistemas lasers de alta potência, foram investigados em vidros e cristais dopados com Nd3+. Nos vidros o estudo foi realizado em função da concentração de íons dopantes. Neste estudo a técnica de LT mostrou ser muito sensível, apresentando resultados com erros bem menores que os existentes na literatura. Seguindo o estudo de perdas, investigamos distorção óptica induzida pela luz em função da temperatura, potência de excitação e polarização no cristal ferroelétrico SBN. Usando a técnica de LT, investigamos as propriedades térmicas através da transição de fase ferroelétrica-paraelétrica em cristais de SBN. Complementando, esta tese contribui significativamente para a caracterização de materiais laser, considerando que vários dos mecanismos de perdas estudados propriamente devem ser levados em conta em projetos de laser. Este trabalho também apresenta a técnica de lente térmica como uma ferramenta valiosa para tal estudo. / In this work we investigate the thermal properties (diffusivity, conductivity, temperature coefficient of the optical path length change, etc) and loss processes owing to ion-ion interactions in laser glassy and crystalline materials. Since the fluorescence quantum efficiency, , is directly related to these mechanisms that lead to luminescence quenching, the studies were performed mainly observing the effects of these processes on . Thermal lens (TL) spectra were used to determine , energy transfer efficiency between matrix-ion, and to analyze effects of \"dead site\" on . A new method based on the TL technique was proposed to determine q and the temperature coefficient of the optical path length change. This new approach was used to investigate concentration quenching mechanisms in glassy materials. It was also used to study effects of OH radicals and other impurities in Yb3+ doped phosphate glasses. Upconversion Auger processes, which are very important for high power laser systems, were investigated in Nd3+ -doped glasses and crystals. In glasses the study was performed as a function of doping ions. In this study the TL showed to be very sensitive, presenting results with uncertainties much smaller than previous literatures. Following the study of losses, we investigate light induced optical distortion as a function of temperature, excitation power, and polarization in SNB ferroelectric crystal. Using the TL technique, the thermal properties through the phase transition ferroelectric-paraelectric in SBN crystals were investigated. In addition, this thesis significantly contributes for characterization of laser materials with potential applications, considering that severa1 of the loss mechanisms studied here must be considered in laser design. This work also presents the TL technique as a valuable to01 for the present study.
384

Espectrometria de lente térmica em sólidos: teoria e aplicações / Thermal Lens Spectrometry in solids:theory and applications

Gláucia Grüninger Gomes Costa 19 October 2005 (has links)
Neste trabalho propomos o estudo da Espectrometria de Lente Térmica, sua teoria e aplicações, visto ser uma técnica de alta sensibilidade e que permite a medida das propriedades termo-ópticas dos materiais, como a difusividade térmica (D), a condutividade térmica (k), desvio do caminho óptico pela temperatura (ds/dT) - para materiais sólidos - ou a variação do índice de refração em relação à temperatura (dn/dT) - para líquidos e gases. Para isso inicialmente fizemos um estudo da teoria da difração. Valendo-se da Integral de Difração de Fresnel Kirchhoff obtivemos a expressão analítica da intensidade de um feixe de laser, difratado por diversos elementos ópticos (aberturas e obstáculos circular e retangular, por exemplo), tanto para o regime da difração de Fresnel, quanto da difração de Fraunhofer. Ainda no estudo da difração propusemos um arranjo experimental muito simples, utilizando-se um laser pointer sem a lente colimadora, permitindo que se obtenha, com grande facilidade, os padrões de difração no campo próximo, o que é difícil nas montagens tradicionais. Na seqüência fizemos uma revisão dos modelos de Lente Térmica tradicionalmente utilizados, modelos parabólico e aberrante. E, na comparação que realizamos entre eles, verificamos que pelos resultados obtidos através de simulações, com o modelo parabólico se apresenta em grande desacordo (>50%) com os obtidos com o modelo aberrante. Desta forma, concluímos que os dados da literatura obtidos na década de 70 e que ainda são utilizados, merecem ser revistos. Por fim, notamos na literatura um crescente interesse em lasers de alta potência, principalmente pelos bombeados por lasers de diodo. Desta forma fizemos um estudo valendo-se do modelo aberrante de Lente Térmica sob o regime de q grande, no qual procuramos verificar o limite de validade dos modelos de L.T. utilizados, observando o surgimento de fenômeno da aberração esférica, juntamente com as estruturas de anéis. / In this work we have proposed the study of Thermal Lens Spectrometry, its theory and applications, because it is a highly sensitive technique that allows the measure of the thermo-optical properties of the materials, as the thermal diffusivity (D), the thermal conductivity (k), the change of optical path length with temperature (ds/dT), for solid materials or the change of refractive index with temperature (dn/dT), for liquids and gases. Initially we studied the diffraction theory. We utilized the Fresnel Kirchhoff Diffraction Integral to obtain the analytic expression of the beam laser intensity, whose was diffracted for several optical elements, so much for the regime of the Fresnel diffraction as the regime of the Fraunhofer diffraction. Continuing in the study of the diffraction we proposed a very simple experimental apparatus where we used a laser pointer without the collimator lens, allowing that it was obtained with great facility the Fresnel diffraction patterns, which are difficult to observe in the common experimental apparatus. In the sequence, we made a revision of the models of Thermal Lens traditionally used, parabolic and aberrant models. And, in the comparison that we accomplished among them, we verified that for the results obtained through simulations, with the parabolic model it comes in great disagreement (>50%) with obtained them with the aberrant model. This way, we concluded that literature’s data obtained in the 70ths and they are still used, they must be reviewed. Finally, we noticed in the literature a growing interest in high power lasers. This way we made a study where we used the aberrant model of Thermal Lens under the regime of great q, in which we look for to verify the limit of validity of the used models, observing the appearance of the spherical aberration together with the rings structure.
385

Aplicação da técnica de varredura-Z para a determinação de parâmetros térmicos. / Z-scan technique to evaluate thermal parameters.

Fernando Fuzinatto Dall\' Agnol 06 March 1998 (has links)
A técnica de varredura-z tem sido bastante utilizada para a determinação do índice de refração não-linear (n2) em meios transparentes. Apresentamos neste trabalho uma análise teórica e resultados da técnica de varredura-z por reflexão, visando o estudo de efeitos térmicos em amostras que possuem coeficientes de absorção muito grandes. Extensões à técnica, tais como: a varredura-z resolvida no tempo e varredura-z resolvidas em freqüência puderam ser aplicadas para medir efeitos térmicos, pois estes são relativamente lentos nos materiais que medimos (água, polímero e vidro). Das componentes linear e quadrática da evolução temporal da transmitância, ou, da segunda componente de Fourier de curvas obtidas em duas freqüências, pode-se extrair parâmetros térmicos como: a capacidade térmica por unidade de massa e a difusividade térmica. Propriedades térmicas são de grande interesse na usinagem de peças, e em estudos sobre tensões estruturais e novos materiais. Pela teoria aqui desenvolvida, dada as constantes térmicas, é possível distinguir os efeitos térmicos e eletrônicos nas amostras que apresentam os dois. / The Z-Scan technique is the most popular one for the determination of the nonlinear index of refraction (n2) of transparent media. In this work we present a theoretical analysis and results of the reflection z-scan technique, aiming the research of thermal effects in highly absorbing materials. Extensions of the technique, such as the time resolved z-scan and the frequency resolved z-scan could be applied to measure thermal effects because they are relatively slow in the materials that we have measured (water, polystyrene and glass). From the linear and quadratic terms of the transmittance time evolution, or, from the second Fourier component of curves obtained in two frequencies, one can extract thermal parameters like: the heat capacity per unit mass and the thermal diffusion coefficient. Thermal properties are of great interest in the manufacture of pieces, and in the study of structure strains and new materials. By the theory presented here, if thermal constants are given, one can distinguish between thermal and electronic effects in samples that present both.
386

Estudo comparativo do estresse oxidativo após facoemulsificação experimental com e sem implante de lentes intra-oculares em cães / Comparative study of the oxidative stress following experimental phacoemulsification with and without intraocular lens implantation in dogs

Adriana Lima Teixeira 29 July 2003 (has links)
O tratamento da catarata em cães têm passado por algumas mudanças. A facoemulsificação reduziu o tempo cirúrgico e a necessidade de incisão extensa; o implante de lentes intra-oculares (LIOs) permitiu restabelecer a emetropia após a remoção do cristalino. O processo inflamatório induzido pelas cirurgias intra-oculares leva a um estado de estresse oxidativo, com efeitos deletérios às estruturas oculares. O presente estudo teve como objetivo avaliar comparativamente o estresse oxidativo após facoemulsificação experimental em cães, com e sem implante de LIO. Doze cães (três machos e nove fêmeas), sem raça definida, com peso médio de 15,8kg, foram submetidos à facoemulsificação bilateral, sendo doze olhos sem implante de LIO (Grupo 1) e doze olhos com implante de LIO de polimetilmetacrilato no saco capsular (Grupo 2). Os animais foram medicados nos períodos pré-operatório e pós-operatório com antiinflamatórios, antibióticos e midriáticos. As amostras de humor aquoso (HA) foram obtidas por paracentese de câmara anterior, sob anestesia geral, nos períodos pré-operatório (T0) e pós-operatório com 1 dia (T1), 2 dias (T2), 3 dias (T3), 7 dias (T7) e 14 dias (T14). O estresse oxidativo foi avaliado por meio da determinação quantitativa de proteínas no HA (método de Lowry), avaliação da atividade antioxidante total do HA utilizando o AAPH, cloreto de 2,2'azobis (2-metilamidinopropano) e avaliação da concentração de ácido ascórbico no HA e no plasma (cromatografia líquida de alta eficiência). Os resultados foram submetidos à análise estatística, utilizando-se o teste t de Student, quando as variáveis apresentaram distribuição normal, e pelo teste de Wilcoxon, quando não houve distribuição normal. Os níveis de proteína total no HA aumentaram nos dois grupos, sendo de forma mais acentuada no Grupo 2 em todos os tempos pós-operatórios: T1 (p= 0,004), T2 (p= 0,002), T3 (p= 0,004), T7 (p= 0,003) e T14 (p= 0,009). A atividade antioxidante total do HA apresentou uma diminuição nos dois grupos, mais acentuada, entretanto, no Grupo 2, com diferença estatisticamente significante nos tempos T1 (p= 0,013), T2 (p= 0,016), T3 (p= 0,002) e T14 (p= 0,033). No tempo T7 (p= 0,155) essa diferença não foi observada. A concentração de ácido ascórbico no HA apresentou uma diminuição marcante no primeiro dia do pós-operatório, seguida por uma recuperação progressiva nos dois grupos. O Grupo 2 mostrou resultados mais baixos, com diferença estatisticamente significante nos tempos T1 (p= 0,003), T3 (p= 0,015), T7 (p= 0,004) e T14 (p= 0,007), exceto em T2 (p= 0,051), quando não houve diferença. A concentração de ácido ascórbico no plasma não variou em função dos procedimentos. A comparação entre os procedimentos sugere que o implante de LIO contribui para a condição de estresse oxidativo. / The cataract treatment in dogs has undergone some changes. Phacoemulsification has reduced the surgical time of cataract extraction and the need of large incision. Intraocular lens (IOL) implantation has allowed emetropic vision recovery. The inflammatory process induced by intraocular surgery leads to an oxidative stress, with ocular structures damage. The purpose of this study was to comparatively evaluate the oxidative stress following phacoemulsification in dogs with and without IOL implantation. Twelve dogs, three male and nine female, mixed breed, with an average weight of 15.8kg were submitted to bilateral phacoemulsification, being twelve eyes without IOL implantation (Group 1) and twelve eyes with polymethylmethacrylate IOL in the capsular bag (Group 2). In the pre-operative and post-operative periods, the medication consisted of anti-inflammatories, antibiotics and mydriatics. Aqueous humor (AH) samples were taken by anterior chamber paracentesis, under general anesthesia in the pre-operative (T0) and post-operative periods after 1 (T1), 2 (T2), 3 (T3), 7 (T7) and 14 (T14) days of the surgery. The oxidative stress was evaluated by quantitative protein levels in the AH (Lowry’s method), total antioxidant activity in the AH using 2,2’ azobis (2-methylpropionamidine) dihydrochloride (AAPH) and ascorbic acid concentration in the AH and plasma (high performance liquid chromatography). Results were submitted to statistical analysis using the t-student test when the variables had a normal distribution and Wilcoxon test when they did not. Aqueous humor total protein levels increased in both groups, more intensively in Group 2 in all post-operative periods: T1 (p= 0.004), T2 (p= 0.002), T3 (p= 0.004), T7 (p= 0.003) and T14 (p= 0.009). Total antioxidant activity in the AH decreased in both groups; however, it was more impressive in Group 2, with statistical significant difference in T1 (p= 0.013), T2 (p= 0.016), T3 (p= 0.002) e T14 (p= 0.033). In T7 (p= 0.155), this difference was not observed. Ascorbic acid concentration in the AH presented a remarkably decrease in the first post-operative day, then started to recover progressively in the two groups. Group 2 showed lower results with statistically significant differences in T1 (p= 0.003); T3 (p= 0.015); T7 (p= 0.004) and T14 (p= 0.007), except in T2 (p= 0.051) when there was no difference. Ascorbic acid concentration in plasma did not vary as a result of the procedures. The comparison between procedures suggests that IOL implantation contributes to an oxidative stress condition.
387

Dosimetria clínica em exame periapical utilizando diferentes colimadores

Travessas, Juliana Andréa Corrêa January 2008 (has links)
Exames radiográficos para fins de saúde constituem a principal fonte de exposição da população à radiação ionizante artificial, devendo empregar a dose mínima necessária para que se obtenha imagem de qualidade. Colimadores retangulares têm sido propostos em substituição aos circulares para reduzir a exposição de órgãos críticos. Este estudo teve por objetivo verificar se existe diferença na dose de radiação nas regiões de cristalino e tireóide durante a realização de um exame periapical completo, em função da forma e do tamanho do colimador utilizado. Trinta pacientes foram aleatoriamente distribuídos em três grupos: 1 - colimador circular convencional com 60 mm de diâmetro; 2 - colimador retangular com 24 x 32 mm² e 3 - colimador retangular com 30 x 40 mm2. As condições de exame foram padronizadas para os três grupos. A dose foi obtida por meio de dosímetros termoluminescentes de LiF:Mg.Cu.P (TLD-100H), que permaneceram, durante a execução das 14 radiografias do exame completo periapical, posicionados sobre os olhos (cristalino) direito e esquerdo e sobre a região da tireóide, abaixo do protetor plumbífero. Os resultados finais foram submetidos aos testes não-paramétricos de Kruskal-Wallis e Friedman, ambos complementados por seus testes de comparações múltiplas, ao nível de significância de 5%. No grupo 2 houve redução significativa na dose de radiação absorvida na região dos olhos em relação aos grupos 1 e 3. Os grupos 2 e 3 apresentaram redução significativa na dose de radiação absorvida na tireóide em relação ao grupo 1. Nos três grupos, a dose absorvida na região dos olhos é significativamente maior do que a dose absorvida pela tireóide. O uso do colimador retangular reduziu significativamente a dose absorvida na tireóide. / X rays examinations are the main source of population's exposure to artificial ionizing radiation. Radiation dose in such examinations should be as low as possible but still ensuring a good image quality. Rectangular collimators have been proposed in substitution to the circular ones in order to minimize the radiation exposure to nearby critical organs. This study aims to compare the radiation doses in the lens of the eyes (right and left) and thyroid gland obtained using different collimators, in a complete periapical examination (14 radiographic exposures). Thirty patients have been randomly allocated to three groups: 1 - using a 60 mm diameter conventional circular collimator; 2 - using a 24 x 32 mm² rectangular collimator; and 3 - using a 30 x 40 mm2 rectangular collimator. The doses were measured by LiF:Mg,Cu,P thermoluminescent dosimeters (TLD-100H) positioned over both right and left eyes and under the lead thyroid protector shield, in the thyroid gland position. Final results were submitted to Kruskal-Wallis and Friedman non-parametric statistics analysis, complemented by multiple comparison tests, with 5% significance level. Group 2 presented a significant dose reduction in the eyes region compared to groups 1 and 3. Groups 2 and 3 showed a significant dose reduction in the thyroid gland region compared to group1.
388

Espectroscopia de lente térmica aplicada a vidros borossilicatos dopados com nanopartículas de sulfeto de enxofre e íons Er3+

Lima Neto, Felix Soares de 28 November 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-12-08T17:00:54Z No. of bitstreams: 1 felixsoaresdelimaneto.pdf: 3304649 bytes, checksum: 1cb4641ba963788c0c4b2143b23a8c5d (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-12-22T11:34:06Z (GMT) No. of bitstreams: 1 felixsoaresdelimaneto.pdf: 3304649 bytes, checksum: 1cb4641ba963788c0c4b2143b23a8c5d (MD5) / Made available in DSpace on 2017-12-22T11:34:06Z (GMT). No. of bitstreams: 1 felixsoaresdelimaneto.pdf: 3304649 bytes, checksum: 1cb4641ba963788c0c4b2143b23a8c5d (MD5) Previous issue date: 2011-11-28 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho foram estudados vidros borossilicatos dopados com nanopartículas de enxofre e íons de Er+3 com o objetivo de determinar a difusividade térmica do sistema vítreo (SNABP), através da técnica de Espectroscopia de Lente Térmica. As propriedades espectroscópicas de tais amostras foram investigadas por meio das medidas de absorção _óptica na região espectral de 400 a 2000 nm. A caracterização das propriedades termo- _ópticas foram realizadas por meio da espectroscopia de Lente Térmica de feixe duplo no modo descasado com excitação em 50mW a 3W. Verificou-se que a difusividade térmica diminuiu quando a matriz SNABP foi dopada com nanocristais de PbS e íons Er3+. Com o tratamento térmico, a amostra SNABP Er manteve a menor difusividade praticamente em todos os tempos. Os resultados foram discutidos em termos de transporte de calor por fônons, onde a redução da difusividade térmica observada foi analisada considerando a diminuição do livre caminho médio dos fônons devido aos efeitos de espalhamento. / In this work we studied borosilicate glasses doped with nanoparticles of sulfur and Er3+ ions in order to determine the thermal diffusivity of the glassy system (SNABP), using the thermal lens technique. The spectroscopic properties of these samples were investigated by measuring absorption in the optical spectral region from 400 to 2000nm. The characterization of the thermo-optic properties was performed by thermal lens tecniqueby with excitation at 50mW to 3W. It was found that the thermal difusivity decreased when the SNABP matrix was doped with PbS nanocrystals and Er3+ ions. Thermal treatment of the SNABP samples reduced the thermal difusivity. The results were discussed in terms of heat transport by phonons, where the observed reduction in thermal diffusivity was analyzed considering the decrease in the mean free path of phonons due to the scattering effects.
389

Interferometria speckle com lasers de diodo multimodo para análise de materiais e dispositivos / Speckle interferometry with multimode diode lasers for analisis of materials and devices

Danilo Mariano da Silva 30 June 2011 (has links)
Neste trabalho foi desenvolvido um novo método voltado para a caracterização de lentes térmicas em materiais fotônicos, utilizados como meios ativos no desenvolvimento de lasers. Este método baseia-se em interferometria por padrão de speckle eletrônico (ESPI), utilizando dois lasers de diodo multímodo sintonizados a diferentes freqüências. Com o ajuste desta diferença, foi possível escolher uma resolução apropriada para medirmos as variações geradas no raio de curvatura da frente de onda, relacionados ao efeito térmico. Para os nossos experimentos escolhemos uma amostra vítrea de aluminato de cálcio dopado com 4% de érbio; e potências de bombeio incidentes de até 1,76 mW do laser de bombeio. Os lasers de diodo foram sintonizados para ter um intervalo de contorno por volta de 120 m. Com o aumento da potência absorvida pela amostra, observamos a diminuição da curvatura da frente de onda incidente na CCD, devido ao aumento da potência da lente térmica gerada. Através de uma análise paraxial dos feixes, foi feita uma aproximação para obtermos os valores das lentes para cada configuração, apresentando comprimentos focais de 131,39 mm a 42,76 mm. / In this work we will develop a new method focused on the caracterization of thermal lenses effect in photonic materials used as active media in lasers design. This method is based on electronic speckle pattern interferometry (ESPI) using two multimode diode lasers tuned to different frequencies. Adjusting this difference we can achieve an appropriate resolution to measure the variability generated within the curvature radius of the wavefront due to thermal lens effect. For our experiments we chose a vitreous sample of calcium aluminate doped with 4% erbium and incident pump powers ranging to 1.76mW. The diode lasers were tuned to have a contour interval of around 120m. With addition in power absorbed by the sample, we observed a decrease in the curvature radius incident on the camera due to increased power of the thermal lens generated. Through a paraxial of the wavefront, an approach was made to obtain the values of the lenses for each configuration, with focal lengths ranging from 131.39 mm to 42.76 mm.
390

Image optimization algorithms on an FPGA

Ericsson, Kenneth, Grann, Robert January 2009 (has links)
In this thesis a method to compensate camera distortion is developed for an FPGA platform as part of a complete vision system. Several methods and models is presented and described to give a good introduction to the complexity of the problems that is overcome with the developed method. The solution to the core problem is shown to have a good precision on a sub-pixel level.

Page generated in 0.0761 seconds