Spelling suggestions: "subject:"luvas"" "subject:"duvas""
1 |
Exposição ocupacional e hipersensibildade ao latex nos trabalhadores das equipes de enfermagem e medica da UTI neonatal de um hospital universitarioLopes, Rosimeire Aparecida Mendes 08 May 2002 (has links)
Orientadore: Maria Cecilia Cardoso Benatti, Ricardo de Lima Zollner / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T15:28:52Z (GMT). No. of bitstreams: 1
Lopes_RosimeireAparecidaMendes_M.pdf: 239011 bytes, checksum: 1a858728c79cdda151cb2df1d2e4b775 (MD5)
Previous issue date: 2002 / Resumo: OBJETIVOS: Identificar a prevalência de hipersensibilidade do tipo I ao látex nos trabalhadores das equipes de enfermagem e médica da Unidade de Terapia Intensiva Neonatal, verificar a associação dos fatores de risco e história de manifestações clínicas. SUJEITOS E MÉTODOS: Tratou-se de estudo descritivo de corte transversal, com 96 trabalhadores da Unidade de Terapia Intensiva Neonatal do Centro de Atenção Integral à Saúde da Mulher da Universidade Estadual de Campinas, sendo 26 enfermeiros, 23 técnicos de enfermagem, 26 auxiliares de enfermagem, dois atendentes de enfermagem, 4 médicos docentes e assistentes e cinco médicos residentes. A coleta dos dados ocorreu de julho a novembro de 2001 e constou da aplicação individual de questionário, coleta de amostra de sangue para o teste sorológico empregandose o método ELISA e testes cutâneos de punctura com antígenos extraídos de luvas de látex. Para análise estatística dos dados foi utilizada análise descritiva. Para verificar associação ou comparar proporções foi utilizado o teste exato de Fisher e na comparação de variáveis contínuas entre dois grupos, o teste de Mann-Whitney. RESULTADOS: A prevalência obtida foi de 8%, sendo dois enfermeiros, três técnicos de enfermagem, um auxiliar de enfermagem, um médico e um residente. Os oito casos tiveram teste cutâneo por punctura positivo e apenas um caso apresentou concordância entre teste sorológico e cutâneo. A média geral da idade foi de 35 anos, com população predominantemente feminina (93%) e onde se encontraram os casos positivos. A equipe de enfermagem representou 75% dos casos positivos, as equipes médica e residente representaram 12,5% cada. Não foram observadas evidências de associações entre o teste cutâneo por punctura e as características sociodemográficas estudadas, a função, o tempo de uso de luvas em anos, a dermatite de contato - prurido (n=36), fissura (n=24) e descamação (n=21) - e urticária. No grupo geral, houve evidência de associação entre o teste cutâneo por punctura e o tempo de uso diário de luvas durante o plantão, onde os casos com teste cutâneo negativo utilizavam luvas por mais tempo durante o plantão, em média 111 minutos, e os positivos utilizavam em média 56 minutos. Houve também evidência de associação para relato de atopia, sendo sete trabalhadores atópicos e um não atópico positivos ao teste cutâneo. A evidência de associação também ocorreu para o relato de eczema, onde quatro de nove sujeitos foram positivos ao teste e para a alergia alimentar, sendo que das frutas relatadas a evidência de associação ocorreu somente para alergia ao abacaxi. Para sintomas provocados pela exposição ambiental aos antígenos, a evidência de associação ocorreu para ataques de espirros, respiração difícil e angioedema e houve evidência de associação entre história sugestiva de alergia durante a realização de exames e teste cutâneo / Abstract: Objective: to identify the prevalence of type 1 hypersensitivity to latex among hospital nursing staff and doctors in a neonatal intensive care unit, verifying the association between the risk factors and the history of clinical manifestation with the test used. Subjects and methods: a cross-section descriptive survey was carried out focusing on ninety-six hospital staff from the neonatal intensive care unit of the Center of Integral Attention to Women¿s Health at the State University of Campinas. We surveyed twenty- three registered nurses, twenty-three nursing technicians, twenty-six nurses¿ aides, 2 nursing attendants, fourteen doctors, and 5 resident doctors. The collection of data occurred from July to November 2001 and all subjects were interviewed, asked to donate blood samples for the ELISA serological test, and to undergo skin prick test with an antigen extracted from latex gloves. A descriptive analysis of the statistical data was done. In order to verify association or to compare proportions, the precise test of Fisher was used and the Mann-Whitney test was used to compare continuous variables between two groups. Results: The prevalence obtained was of 8%; two registered nurses, three nursing technicians, one nurse¿s aide, one resident doctor and one doctor. The eight cases of the skin prick tests were positive, and only one serological test was in agreement with the skin test. The positive cases (93%) consisted predominantly of females with an average age of 35. The nursing staff made up 75% of the positive cases, while resident doctors and doctors made up 12,5% of the cases each. There was no evidence of associations between the skin prick test and the sociodemographic characteristics studied; the function; exposure to latex in number of years; contact dermatitis ¿ itching (n=36), cracking (n=24) and peeling (n=21) ¿ and urticaria. In the group as a whole, there was evidence of an association between the skin prick test and the daily exposure time to latex gloves while on duty, where individuals who had used latex gloves for a long period of time (111 minutes) had negative skin prick test, whereas individuals who had used the gloves for 56 minutes on average had positive skin prick test. Also, there was evidence of association between the reported atopy and the skin prick test, where eight health care workers¿ skin prick tests were positive, seven workers were atopic and one was not. Evidence of association also occurred for the reported eczema cases, where four out of nine individuals¿ tests were positive. And for the reported food allergy cases, pineapple showed evidence of association with the skin prick test. For symptoms provoked by environmental exposure to antigens, evidence of association occurred for sneezing attacks, respiration difficulty and angiodema. Also, there was evidence of association between a history suggestive of allergies in exam procedure and skin prick test / Mestrado / Enfermagem e Trabalho / Mestre em Enfermagem
|
2 |
Porjecto de optimização de componentes e processos do conjunto porta-luvas do Vokswagen Golf A05Pinto, Daniel Machado Gomes January 2010 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2011
|
3 |
Avaliação das propriedades fisico-químicas das luvas de policloreto de Vinila (PVC) sob regime de vigilância sanitária. / Evaluation of the physico-chemical properties of polyvinyl chloride gloves (PVC) under health surveillance.MARTINS, Priscilla Consigliero de Rezende. 17 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-17T12:40:12Z
No. of bitstreams: 1
PRISCILLA CONSIGLIERO DE REZENDE MARTINS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1527771 bytes, checksum: cc67203373e93ed35f44365878e7d5cb (MD5) / Made available in DSpace on 2018-04-17T12:40:12Z (GMT). No. of bitstreams: 1
PRISCILLA CONSIGLIERO DE REZENDE MARTINS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1527771 bytes, checksum: cc67203373e93ed35f44365878e7d5cb (MD5)
Previous issue date: 2014-10-28 / A partir de 1980, em virtude do surgimento da AIDS/HIV, o Centers for Disease
Control and Prevention (CDC) preconizou as “Precauções Universais”, e então
as luvas passaram a ser utilizadas amplamente nos serviços de saúde.
Popularizado o uso das luvas, começaram a surgir os primeiros relatos de
reações alérgicas induzidas pelo látex. A partir de então, as empresas
desenvolveram substitutos sintéticos para o látex, tais como PVC. Em 2011, foi
publicada a Resolução RDC nº 55 que estabeleceu os requisitos mínimos de
identidade e qualidade para as luvas cirúrgicas e luvas para procedimentos
não cirúrgicos de borracha natural, de borracha sintética, de mistura de
borrachas natural e sintética e de policloreto de vinila. Desta forma, este
trabalho propôs a caracterização e a avaliação das luvas para procedimentos
não cirúrgicos produzidas de policloreto de vinila, no intuito de verificar se as
luvas estão em conformidade em relação à Norma - ABNT NBR ISO 11193-2.
Para isso foram avaliadas 3 diferentes marcas comerciais de luvas para
procedimentos não cirúrgicos de PVC cadastradas na ANVISA, sendo
caracterizadas por DRX, FTIR, MEV, EDS, molhabilidade, e avaliadas quanto
às dimensões, à impermeabilidade, e à força de ruptura e alongamento na
ruptura conforme metodologia da norma. No FTIR observaram-se quantidades
de grupamentos químicos semelhantes em todas as amostras analisadas. O
MEV demonstrou a morfologia da superfície lisa e plana das Luvas D e E,
enquanto a Luva S apresentou superfície texturizada e uniforme. Evidenciouse
que as amostras das luvas de policloreto de vinila ensaiadas não
atenderam aos requisitos mecânicos estabelecidos na norma vigente,
principalmente no que diz respeito ao alongamento mínimo da ruptura de
350%. Diante do resultado, sugere-se o programa de monitoramento e
avaliação da conformidade com um maior número de amostras de luvas de
policloreto de vinila, assim como a posterior avaliação da Resolução RDC 55,
de 4 de novembro de 2011, para avaliar a necessidade da inclusão das luvas
de policloreto de vinila no escopo de certificação compulsória. / During the mid-1980´s, due to the emergence of AIDS, the Centers for Disease
Control and Prevention (CDC) introduction the "Universal Precautions" and
gloves began to be widely used in health services. The use of gloves was
popularize in medical and surgical procedures, and reports of allergic reactions
induced by latex began to emerge. Since then, companies have developed
synthetic substitutes for latex, such as PVC. In 2011, was published the
Resolution RDC nº 55 which established the minimum requirements of identity
and quality for surgical and exam gloves made of natural rubber, synthetic
rubber, a mixture of natural and synthetic rubbers and polyvinyl chloride. Thus,
this study proposes the characterization and evaluation of exam vinvyl gloves,
in order to check if the gloves meet the requirements of the standard ABNT
NBR ISO 11193-2. Three different brands of regularized exam gloves at
ANVISA were evaluated, being characterized by XRD, FTIR, SEM, EDS,
Wetting Test, as well as evaluated the size, impermeability, and tensile
properties according to the standard methodology. It was observed similar
quantities of chemical groups in all samples analyzed by FTIR. The SEM
morphology showed a smooth flat surface of the gloves D and E, while the S
glove presented textured and uniform surface. It was shown that samples of
vinyl gloves tested did not meet the standard´s mechanical requirements,
especially the breaking elongation´s requirement of 350%. A conformity
assessment with a larger sample of vinyl gloves it is suggested, as well as a
further review of the Resolution RDC 55/2011 to assess the need for inclusion
of vinyl gloves in the scope of mandatory certification.
|
4 |
Reações do tipo alérgico ao látex ocorridas em funcionários usuários de luvas em unidades públicas de saúde, em FlorianópolisBuss, Ziliani da Silva January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Farmácia. / Made available in DSpace on 2012-10-22T12:15:35Z (GMT). No. of bitstreams: 1
226902.pdf: 1818562 bytes, checksum: 7dd62db7b74b73f72e51e034e03c9d9e (MD5)
|
5 |
Estudo comparativo entre a utilização de luvas únicas e duplas em três especialidades odontológicasCristina de Oliveira Andrade Marques, Maria January 2005 (has links)
Made available in DSpace on 2014-06-12T23:00:04Z (GMT). No. of bitstreams: 2
arquivo8505_1.pdf: 1201818 bytes, checksum: 0d4d2784f3e3d2b257125d75aabd53de (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2005 / Para o devido controle da infecção cruzada em atendimentos odontológicos, é necessária a utilização dos equipamentos de proteção individual, tais como o uso de luvas. No entanto, as perfurações em luvas são comuns, embora, não sejam freqüentemente detectadas pelos cirurgiões-dentistas. O presente estudo propôs-se avaliar e comparar a ocorrência de perfurações quando da utilização de uma ou duas luvas durante a prática odontológica; e, a correlacionar as especialidades de Odontopediatria, Dentística e Endodontia com os índices de perfurações. Foi avaliada a integridade de 540 luvas de procedimento, sendo 60 luvas utilizadas de forma única e 120, utilizadas de forma dupla, por cada especialidade em estudo, através do método de pressão de água e com a utilização do corante Rodamina B diluído. Do total de luvas analisadas, 18,7% apresentaram pelo menos uma perfuração. Não houve diferenças estatisticamente significantes entre o número de perfurações por grupo: Odontopediatria (21,7%); Dentística (15,5%); e, Endodontia (18,9%). Observou-se maior número de perfurações nas luvas únicas do que nas luvas internas das luvas duplas e, com exceção do grupo de Dentística, as diferenças entre estas proporções foram estatisticamente significantes. Do total das perfurações encontradas em todos os grupos, 52,9% situavam-se na mão não dominante (no lado esquerdo). Quanto às localizações, 64,7% das perfurações estavam na palma e 35,3%, no dorso das luvas; 16% das perfurações ocorreram no centro (dorso/palma) e, 84,0%, nos dedos. Houve, portanto, uma maior efetividade da barreira quando se utilizou duasluvas, sendo indicada esta forma de uso de luvas em procedimentos considerados de risco, mas, não se evidenciou correlação entre as diferentes especialidades odontológicas e o índice de perfurações em luvas
|
6 |
O uso de luvas de proteção no corte manual de cana-de-açucarGonzaga, Maria Cristina 12 September 2004 (has links)
Orientadores: Roberto Funes Abrahão, Oscar Antonio Braunbeck / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-04T02:14:48Z (GMT). No. of bitstreams: 1
Gonzaga_MariaCristina_M.pdf: 3851067 bytes, checksum: 0a77b52d36f9fc85af9a70a4f8bf68d5 (MD5)
Previous issue date: 2004 / Resumo: A negociação tripartite entre a FUNDACENTRO, o Sindicato dos Empregados Rurais de Araraquara e a Usina Santa Cruz permitiu a realização do estudo sobre os equipamentos de proteção individual (EPI) e das ferramentas de trabalho durante a execução da atividade de cortar manualmentea cana-de-açúcar. A problemática se manifestou frente às estratégias utilizadas pelos trabalhadores para viabilizarem o uso conjunto das ferramentas e dos EPI, prescritos como obrigatórios pela Norma Regulamentadora Rural n o 4 (Ministério do Trabalho e Emprego)e pelas normas internasda empresa. A principal estratégia desenvolvida foi emborrachar o cabo do facão, com o objetivo de minimizar o efeito da falta de aderência entre a luva de proteção e o cabo do facão. A metodologia utilizada no presente estudo foi analisar qualitativamente, através da aplicação de questionários, quatro modelos de luvas junto a quarenta e sete trabalhadores, além de analisar quantitativamente o coeficiente médio de atrito estático desenvolvido entre as luvas e a madeira com que é confeccionado o cabo do facão; os experimentosforam feitos com madeira limpa e emborrachada e com luvas novas e usadas. Nesta etapa testou-se a seguinte hipótese: os valores do coeficiente de atrito estático desenvolvido entre as luvas de proteção e a superficie do cabo do facão dependem do tipo de luva, da condição da luva e do tipo de superfície. A hipótese apresentada foi confirmada, pois o coeficiente de atrito estático depende do tipo de luva, da condição da luva e do tipo de superfície. A pesquisa qualitativa apontou a luva de proteção de raspa de couro e nylon como a preferida dos trabalhadores, pelo conforto advindo do fato desta luva se ajustar bem às mãos, não prejudicar os movimentos e não ocasionar danos às mãos. o coeficiente de atrito não foi prioritário na seleção das luvas feita pelos trabalhadores, pois este problema é passível de minimização pelo desenvolvimento de estratégias como o emborrachamento do cabo do facão. Os atributos principais na seleção das luvas foram outros não passíveis
de estratégias, ou seja, tamanho e localização de costuras e qualidade do material / Abstract: The tripartite negotiation among FUNDACENTRO,the Rural Workers' Union of Araraquara and the Santa Cruz Sugar Mill allowed for the undertaking of a study on personal protective equipment (PPE), as well as on tools used during the activity of manual cutting of sugarcane. The problem manifested itself in the face of the strategies adopted by workers to make it feasible the concomitant usage of tools and PPE prescribed as obligatory by the Rural Rule n° 4 (Ministry of Labor and Employment) and internal norms of the company. The main strategy developed was to produce rubber-coatedknife handles in order to minimize the effect of lack of adhesion between the safety glove and the knife handle. The methodology used in the present study was to analyze qualitatively, by means of the appJicationof questionnaires, four modeJs of gJoves being used by forty-seven workers, and analyze quantitatively the average coefficient of static friction developed between the gloves and the wood used in the manufacturing of the knife handle; the experiments were carried out with clean and rubber-coatedwood and with new and used gloves. In this stage the following hypothesis was tested: the values of coefficient of static friction developed between the safety gloves and the surface of the knife handle depend on the kind
of glove,the conditionof the glove and the kind of surface. The hypothesis presented was confirmed, because the coefficient of
static friction depends on the kind of glove, the condition of the glove and the kind of surface. The qualitativeresearch pointed to the safety glove made of leather chips and nylon as the workers' favorite, due to the comfort resulting from the fact that this glove adjusts well to the hands, does not prevent the motions and does not cause damages to the hands. The coefficient of friction was not a priority in the selection of gloves made by workers, since this problem can be minimized by means of the developmentof strategies such as coating the knife handle with rubber.The main attributes in the selection of gloves were other ones not liable to strategies, i.e., the size and location of seams and the quality of the material / Mestrado / Maquinas Agricolas / Mestre em Engenharia Agrícola
|
7 |
Estudo da prevalência de sensibilização ao látex em estudantes do curso de odontologia da Universidade do Vale do ItajaíBernhardt, Cláudia dos Santos Dutra January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Curso de Pós-Graduação em Ciências Médicas. / Made available in DSpace on 2012-10-18T03:30:26Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T21:34:54Z : No. of bitstreams: 1
182530.pdf: 4339796 bytes, checksum: 1b7bfab2b30d1aef8cb1aae6ada0dedb (MD5) / A exposição ao látex da borracha natural pode ocasionar reações de hipersensibilidade do tipo I. A prevalência para os trabalhadores da área da saúde está situada na faixa de 2,9% a 22%. Os acadêmicos e profissionais da odontologia também estão expostos ao látex. O objetivo deste estudo foi descrever a ocorrência de hipersensibilidade do tipo I ao látex e os fatores associados à sensibilização ao látex em estudantes do Curso de Odontologia da Universidade do Vale do Itajaí, no período de outubro de 2000 a abril de 2001. Os dados foram coletados por meio da aplicação de um questionário, da realização de testes cutâneos de leitura imediata para o látex e para o Dermatophagoides pteronissynus e da dosagem de IgE total e de IgE específica in vitro. Participaram do estudo 161 alunos, dos quais cinco apresentaram testes cutâneos positivos para o látex. Os fatores associados à sensibilização ao látex com significado estatístico foram os seguintes: história prévia de alergias, presença de teste cutâneo positivo para Dermatophagoides pteronissynus e presença de algum sintoma nas mãos durante ou após o uso de luvas de látex. Não houve associação estatisticamente significativa entre a presença de sintomas sugestivos de alergia ao látex e o teste cutâneo positivo para este. A prevalência de hipersensibilidade do tipo I ao látex encontrada foi de 3,1%.
|
8 |
Sintese de dispersões aquosas de poliuretano como proposta de substituição ao latex naturalSpinardi Junior, Walter 20 December 2001 (has links)
Orientador: Lucia H. I. Mei / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-01T13:27:18Z (GMT). No. of bitstreams: 1
SpinardiJunior_Walter_M.pdf: 1958784 bytes, checksum: d512d999a2f5a4db1b0faa95bc9fd4dc (MD5)
Previous issue date: 2001 / Resumo: Artigos destinados ao uso médico-hospitalar (luvas) ou de prevenção contraceptiva (preservativos) são geralmente fabricados com látex natural, que possui um ótimo balanço de propriedades mecânicas. Todavia, por se tratar de um produto natural, a presença de determinados tipos de proteínas na sua composição, bem como alguns ingredientes usados na produção vêm ultimamente causando reações alérgicas em seus consumidores. O poliuretano, por ser não alergênico e possuir uma combinação de boa resistência e elasticidade, é uma das alternativas mais eficientes para se solucionar tal problema. Porém, atualmente no seu uso são utilizados solventes de base orgânica, que causam problemas ambientais e de saúde ocupacional. Neste trabalho, foram estudadas formulações de dispersões aquosas de poliuretano como uma alternativa viável do ponto de vista ecológico e de desempenho em relação às propriedades mecânicas do látex natural. Formulações com diferentes ingredientes (diisocianatos e polióis) e concentrações de segmentos flexíveis e rígidos foram obtidas. Filmes foram obtidos das dispersões e submetidos a ensaios de propriedades físicas, caracterização por infravermelho, calorimetria diferencial de varredura (DSC) e análise dinâmico mecânica (DMA). Os resultados obtidos foram avaliados comparativamente aos de filmes obtidos de uma formulação de látex natural. Através da análise de DSC, verificou-se a relação inversamente proporcional entre a massa molecular do poliol usado e a temperatura de transição vítrea do poliuretano. Verificou-se através dos resultados dos ensaios físicos, que é possível obter-se filmes originados de dispersões aquosas de poliuretano com propriedades físicas semelhantes aos do látex natural (dispersão DAPU2), com uma concentração de segmentos flexíveis (75,4%) superior aos rígidos (24,6%) / Abstract: Products used as medical devices (gloves) or contraceptives (condoms) generally are made from natural latex due to its outstanding balance of physical properties. However, presence of proteins and chemical ingredients in its formulation can lead to human allergic reactions. Polyurethane has been used as a natural latex substitute, due to its good properties of strength and elasticity and non-allergenicity. Manufacturing process using polyurethanes generally uses organic solvent based solutions, that causes problems in terms of environmental and occupational healthy. In this work, formulations of polyurethane aqueous dispersions were studied as an alternative related to environmental subject and physical properties performance compared to naturallatex. Formulations using different ingredients (diisocyanates and polyols) and concentrations of hard and soft segments were done. Films were prepared and submitted to physical properties tests, infrared characterization, differential scanning calorimetry (DSC) and dynamical mechanical analysis (DMA). Results were comparatively evaluated with films from natural latex formulation. Through the analysis of DSC the relationship was verified inversely proportional between the molecular mass of the used poliol and the glass temperature transition (Tg) of the polyurethane. LIt was verified through the results of the physical properties that it is possible to obtain films originated of polyurethane aqueous dispersions with mechanical properties similar to the naturallatex ones (dispersion DAPU2), using a concentration of flexible (75,4%) superior to the hard segments (24,6%) / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
|
9 |
Tecnologia educacional como estratégia para o uso de luvas pelos profissionais de enfermagem visando a precaução de contatoPadilha, Jovíria Márcia Ferreira de Oliveira January 2014 (has links)
Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2017-03-16T17:11:05Z
No. of bitstreams: 1
Joviria Marcia Ferreira de Oliveira Padilha.pdf: 1968331 bytes, checksum: b469b4bab4f213247f9b3817b0d25da6 (MD5) / Made available in DSpace on 2017-03-16T17:11:05Z (GMT). No. of bitstreams: 1
Joviria Marcia Ferreira de Oliveira Padilha.pdf: 1968331 bytes, checksum: b469b4bab4f213247f9b3817b0d25da6 (MD5)
Previous issue date: 2014 / Mestrado Profissional em Enfermagem Assistencial / A infecção relacionada à assistência à saúde (IRAS) é considerada um problema de saúde pública em esfera mundial. Assim, torna-se preponderante a intervenção nos cuidados e prevenção destes agravos. Diante desta prerrogativa, o estudo tem como objeto: a precaução de contato a partir de uma tecnologia educacional (TE), visando o uso de luvas pelos profissionais de enfermagem. Objetivo geral: propor uma TE em forma de mídia audiovisual visando à adequação e/ou adesão dos profissionais de enfermagem às medidas de precaução de contato, foco em luvas. Objetivos específicos: identificar os fatores que interferem na adesão e/ou adequação às medidas de precaução de contato na utilização das luvas de procedimentos e estéreis pela equipe de enfermagem; elaborar uma TE visando adesão e adequação dos profissionais de enfermagem às medidas de precaução de contato, foco em luvas, a partir das falas dos profissionais; validar uma TE em forma de mídia audiovisual, visando adequação e adesão às medidas de precaução de contato com foco nas luvas. Metodologia: pesquisa de abordagem quantiqualitativa do tipo metodológica. O cenário da pesquisa foi o Hospital Universitário Antônio Pedro da Universidade Federal Fluminense. Os participantes foram 66 profissionais distribuídos em quatro etapas do estudo. Para elaboração e validação da TE, a coleta de dados ocorreu nas quatro etapas. A 1ª etapa: realizaram-se entrevistas e a análise temática segundo Bardin. Critérios de inclusão: profissionais de enfermagem da clínica cirúrgica, diaristas ou plantonistas, estatutários ou contratados, em exercício. Critérios de exclusão: profissionais em férias e/ou licenças médicas; 2ª etapa: elaboração da TE a partir das categorias que emergiram da primeira etapa; 3ª etapa: validação de TE. Nesta etapa foram utilizados instrumentos de validação, escala Likert, respondidos por juízes especialistas e público alvo. Os itens do instrumento analisados receberam diferentes valorações em cada bloco, sendo considerados válidos os itens que obtiveram concordância maior ou igual a 70% pelos avaliadores desta etapa; 4ª etapa: adequação da TE a partir da avaliação dos profissionais. Resultados: a partir da fala dos profissionais emergiram três categorias, a saber: Conhecimento geral acerca do uso de luvas; A utilização das luvas na prática de enfermagem e suas implicações; Avaliação do material das luvas. A partir destas categorias, foi elaborada uma TE em forma de mídia audiovisual, cuja validação dos resultados atingiu índice de concordância superior a 80%. Conclui-se que a elaboração e aplicação de TE voltadas para o ensino e aprendizagem do profissional são primordiais para a segurança do paciente, do profissional e do ambiente, minimizando os riscos de infecções cruzadas / The Infection related to health care (IRAS) is considered a public health problem in the whole world. Thus, a major intervention in the care and prevention of these diseases is of utmost importance. In the view of this prerogative, the current object of this study is: the contact precautions as an educational technology (ET), to the use of gloves by nursing professionals. Overall objective: to propose an ET in audiovisual media format in order to improve adhesion/adjustments of nursing professionals to contact precautions, focusing in the use of gloves. Specific objectives: to identify the factors that influence in adherence and/or adequacy for contact precautions with the use of procedure and sterile gloves by nursing staff; to develop an ET aiming at adherence and adequacy of nursing professionals to contact precautions, focusing in the use of gloves, from the speeches of professionals; to validate an ET in audiovisual media format, aiming to adequacy and adherence to contact precautions focused in the use of gloves. Methodology: Research with quantiqualitative approach of methodological type. The research scenario was the Antônio Pedro University Hospital, Fluminense Federal University. Participants were 66 professionals divided into four stages of the study. For development and validation of ET, data collection occurred in all the four stages. 1st stage: interviews and Bardin’s thematic analysis were conducted. Inclusion criteria: nurses of surgical clinic department, resident or day labor, statutory- or private-contracted, and currently active. Exclusion criteria: professionals on vacation and / or in sick leave; 2nd stage: preparation of the ET based the categories that emerged from the first stage; 3rd stage: ET validation. At this stage the Likert scale and validation instruments were used, answered by expert judges and target audience. The instrument items analyzed received different valuations in each block, being considered as valid the items with agreement levels greater than or equal to 70% by the evaluators of this stage; 4th stage: adequacy of ET by the evaluation of professionals. Results: from the speech of professionals emerged three categories, namely: General knowledge about the use of gloves; the use of gloves in nursing practice and its implications; analysis of the glove material. From these categories, an ET was prepared in audiovisual media format, and the validation of its results reached an agreement index higher than 80%. It is concluded that the development and application of an ET facing professional education and learning are essential for the safety of patients, professionals and the environment, minimizing the risk of cross-infection
|
10 |
Avaliação da integridade de luvas cirúrgicas em um hospital oncológico do interior paulista / Evaluation of the integrity of surgical gloves in an oncological hospital in the state of São PauloLuize, Paula Batista 11 May 2018 (has links)
Introdução: a utilização de luvas cirúrgicas estéreis é uma estratégia fundamental para a prevenção de infecção do sítio cirúrgico e para a proteção da equipe cirúrgica. Entretanto é comum a ocorrência de perfurações de luvas durante os procedimentos cirúrgicos as quais, em sua maioria, não são percebidas pelos profissionais. Objetivos: testar a associação entre a ocorrência de perfuração de luvas cirúrgicas e o número de cirurgiões em campo, o tempo de duração da cirurgia, o tipo de cirurgia, o tipo de abordagem cirúrgica e a especialidade cirúrgica. Materiais e Métodos: trata-se de um estudo de corte transversal realizado num hospital especializado em oncologia do interior paulista. A população do estudo foi composta por 3.966 luvas utilizadas em 359 cirurgias realizadas no referido hospital, no período de 01 de janeiro a 28 de fevereiro de 2018. A avaliação da integridade das luvas cirúrgicas foi realizada por meio de análise visual e da insuflação de líquido, conforme a norma EN 455-1. Os dados foram analisados por meio de estatística descritiva e pela técnica de regressão logística multivariada, utilizando-se o programa estatístico IBM SPSS Statistics versão 21. Resultados: Das 359 cirurgias analisadas, 145 (40,4%) cirurgias apresentaram luvas perfuradas. Das 3.966 luvas coletadas, 254 (6,4%) apresentaram perfuração. Do total de perfurações identificadas, 163 (64,2%) ocorreram na mão esquerda, atingiram o dedo indicador 94 (37,0%). As varáveis associadas à perfuração de luvas identificadas no modelo final foram cirurgias com tempo de duração acima de 120 minutos (OR: 3,06; IC 95%: 1,52 - 6,14) e cirurgias realizadas pelas especialidades da Ortopedia (OR: 4,40; IC95%: 2,36 - 8,20), do Tórax (OR: 3,28; IC95%: 1,75 - 6,17), da Urologia (OR: 2,97; IC95%: 1,53 - 5,76) e do Digestivo Baixo (OR: 2,35; IC95%: 1,22 - 4,54). Ressalta-se que as cirurgias realizadas por vídeo se constituíram num fator de proteção (OR: 0,35; IC95%: 0,22 - 0,56). Conclusão: o presente estudo confirmou a associação entre a perfuração de luvas e tempo de duração da cirurgia acima de 120 minutos e especialidades cirúrgica, além disso, as cirurgias realizadas por vídeo se constituíram como um fator de proteção. Acredita-se que os resultados obtidos poderão subsidiar a proposição de medidas de prevenção e consequentemente contribuir para a segurança dos pacientes e dos profissionais da área da saúde / Introduction: the use of sterile surgical gloves is a fundamental strategy for the prevention of infection of the surgical site and for the protection of the surgical team. However, perforated gloves are common during surgical procedures which, for the most part, are not perceived by professionals. Objective: to test the association between the occurrence of surgical glove perforation and the number of surgeons in the surgery, the duration of the surgery, the type of surgery, the type of surgical approach and the surgical specialty. Materials and Methods: this is a crosssectional study conducted at a specialized hospital in oncology in the state of São Paulo. The study population consisted of 3.966 gloves used in 359 surgeries performed at the referred hospital, from January 1 to February 28, 2018. The evaluation of surgical glove integrity was performed through visual analysis and fluid insufflation, in accordance with EN 455-1. Data were analyzed using descriptive statistics and the multivariate logistic regression technique using the IBM SPSS Statistics version 21 statistical program. Results: of the 359 surgeries analyzed, 145 (40,4%) surgeries had perforated gloves. Of the 3.966 gloves collected, 254 (6,4%) presented perforation. Of the total number of perforations identified, 163 (64,2%) occurred in the left hand, reaching the index finger 94 (37,0%). The variables associated with the perforation of gloves identified in the final model were surgeries with duration time over 120 minutes (OR: 3,06; 95% CI: 1,52 - 6,14) and surgeries performed by Orthopedics specialties (OR: 4,40; 95% CI: 2,36 - 8,20), Thorax (OR: 3.28; 95% CI:1.75 - 6.17), Urology (OR: 2,97; 95% CI: 1,53 - 5,76) and the Low Digestive (OR: 2.35; 95% CI: 1,22 - 4,54). It should be emphasized that the surgeries performed by video were constituted as a protection factor (OR: 0,35; 95% CI: 0,22 - 0,56). Conclusion: the present study confirmed the association between the perforation of gloves and the duration of surgery over 120 minutes and surgical specialties, besides that the surgeries performed by video were constituted as a protection factor. It is believed that the results obtained may support the proposal of preventive measures and consequently contribute to the safety of patients and health professionals
|
Page generated in 0.0479 seconds