• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 91
  • 87
  • 37
  • 9
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 253
  • 75
  • 38
  • 36
  • 28
  • 24
  • 23
  • 22
  • 20
  • 19
  • 19
  • 18
  • 18
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Análise fotoelástica de implantes cone-Morse posicionados ao nível e infraósseo na região posterior / Photoelastic analysis of morse taper implants positioned equicrestal and subcrestal in the posterior area

Suleima do Vale Alves 06 December 2013 (has links)
O meio cientifico na área odontológica está sempre procurando materiais e tratamentos que de maior previsibilidade e sucesso em longo prazo. Este trabalho procurou avaliar, por meio de análise fotoelástica, o comportamento das tensões geradas de cargas exercidas em prótese sobre implante posteriores adjacente ou não a réplicas de dentes. Todos os implantes cone-Morse utilizados eram da marca ANKYLOS®, da Dentsply, de 3,5 x 9,5 mm. Para a confecção das réplicas dos dentes utilizou-se resina Luxatemp e foram confeccionadas coroas unitárias de cerâmica. Foram confeccionados três modelos contendo dente-implante-dente, entretanto em cada modelo o implante apresentava-se em uma altura diferente em relação à crista marginal (nível, 1,5 mm e 3,0 mm subcristal). Foram fabricados mais três modelos com as mesmas características, mas com ausência do segundo molar e três modelos com apenas o implante em posição. Os modelo com três elementos com carregamento axial (oclusão balanceada) apresentaram tensões com direção para a região apical conforme o implante apresentava-se mais subcristal; os modelo com dois elementos com carregamento axial (oclusão balanceada), modelos com implantes unitários com carregamento axial (pontual central), modelos com implantes unitários com carregamento axial (pontual distal) e os modelos com implante unitário com carregamento não axial (vestibular-lingual) apresentaram também o mesmo comportamento em relação ao direcionamento das tensões para a região apical. A diferenciação entre os modelos foi observada apenas em relação a intensidade das tensões de algumas regiões. Desta maneira pode-se concluir que quanto mais subcristal o implante se encontra menor é a tensão na região cristal, independentemente da presença ou não de dentes adjacentes, e a presença de dentes adjacentes à prótese sobre implante influência na intensidade de tensão gerada nos implantes, mas não há influência no direcionamento dessas tensões. / The scientific environment in dentistry is always searching for materials and treatments more predictable and which presented a long-term success. The aim of this study was to evaluate by photoelastic analysis, the stresses behavior generated by loads applied to the implant prosthesis posterior between or not to teeth. All implants Morse taper used (Ankylos®,Dentsply Implants) with 3.5mm x 9.5mm. The teeth were made by Luxatemp resin and ceramic crowns were fabricated. Three models containing tooth - implant - tooth were built, meanwhile each model had the implant in different height from the marginal bone crestal level (equicrestal, 1.5mm and 3.0 mm the crest). Subsequently, other three models were made with the same characteristics, but without the second molar and another three models just with the implant in position. Models witch three elements with axial loading (balanced occlusion) had tensions with direction to the apical region as the implant had become more subcristal , models with two elements with axial loading ( balanced occlusion ) , models with single implants with axial loading ( central point ) , models with single implants with axial loading (distal point ) and models with single implant with no axial loading (buccal - lingual) also showed the same behavior with respect to the direction of the stresses to the apical region. The differentiation between the models was only observed for the intensity of the stresses in some regions. Thus it can be concluded that the more the implant is subcristal lower the tension in the crystal region regardless of the presence or absence of adjacent teeth, and the presence of adjacent teeth prosthesis on the implant influence on the stress intensity generated in the implants but no influence on the direction of these stresses.
102

Structure of attractors and estimates of their fractal dimension / Estrutura de atratores e estimativas de suas dimensões fractais

Matheus Cheque Bortolan 08 March 2013 (has links)
This work is dedicated to the study of the structure of attractors of dynamical systems with the objective of estimating their fractal dimension. First we study the case of exponential global attractors of some generalized gradient-like semigroups in a general Banach space, and estimate their fractal dimension in terms of themaximumof the dimension of the local unstablemanifolds of the isolated invariant sets, Lipschitz properties of the semigroup and rate of exponential attraction. We also generalize this result for some special evolution processes, introducing a concept of Morse decomposition with pullback attractivity. Under suitable assumptions, if (A, \'A POT. \') is an attractor-repeller pair for the attractor A of a semigroup {T (t ) : t 0}, then the fractal dimension of A can be estimated in terms of the fractal dimension of the local unstable manifold of \'A POT. \', the fractal dimension of A, the Lipschitz properties of the semigroup and the rate of the exponential attraction. The ingredients of the proof are the notion of generalized gradient-like semigroups and their regular attractors, Morse decomposition and a fine analysis of the structure of the attractors. Also, making use of the skew product semiflow and its Morse decomposition, we give some estimates of the fractal dimension of the pullback attractors of non-autonomous dynamical systems / Este trabalho é dedicado ao estudo da estrutura dos atratores de sistemas dinâmicos com o objetivo de obter estimativas de suas dimensões fractais. Primeiramente estudamos o caso de atratores globais exponenciais de alguns semigrupos gradient-like generalizados em um espaço de Banach geral, e estimamos suas dimensões fractais em termos da máxima dimensão das variedades instáveis locais dos conjuntos invariantes isolados, a propriedades de Lipschitz do semigrupo e da taxa de atração exponencial. Também generalizamos este resultado para alguns processos de evoluções especiais, introduzindo um conceito de decomposição de Morse com atração pullback. Sob hipóteses apropriadas, se (A, \'A POT. \') é um par atrator-repulsor para o atratorA de um semigrupo {T (t ) : t 0}, então a dimensão fractal de A pode ser estimada em termos da dimensão fractal da variedade instável de \'A POT. \', a dimensão fractal de A, as propriedades de Lipschitz do semigrupo e a taxa de atração exponencial. Os ingredientes da demonstração são a noção de semigrupos gradient-like e seus atratores regulares, decomposição de Morse e uma análise fina da estrutura dos atratores. Além disto, fazendo uso do skew product semiflow e sua decomposição de Morse, damos estimativas da dimensão fractal dos atratores pullback de sistêmas dinâmicos não-autônomos
103

Discrete Morse complex of images = algorithms, modeling and applications = Complexo discreto de Morse para imagens: algoritmos, modelagem e aplicações / Complexo discreto de Morse para imagens : algoritmos, modelagem e aplicações

Silva, Ricardo Dutra da, 1982- 11 May 2013 (has links)
Orientador: Hélio Pedrini / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Computação / Made available in DSpace on 2018-08-24T00:14:20Z (GMT). No. of bitstreams: 1 Silva_RicardoDutrada_D.pdf: 13549105 bytes, checksum: 3d49e5116a70a72601ba4cc3b3c85762 (MD5) Previous issue date: 2013 / Resumo: A Teoria de Morse é importante para o estudo da topologia em funções escalares como elevação de terrenos e dados provenientes de simulações físicas, a qual relaciona a topologia de uma função com seus pontos críticos. A teoria contínua foi adaptada para dados discretos através de construções como os complexos de Morse-Smale e o complexo discreto de Morse. Complexos de Morse têm sido aplicados em processamento de imagens, no entanto, ainda existem desafios envolvendo algoritmos e considerações práticas para a computação e modelagem dos complexos para imagens. Complexos de Morse podem ser usados como um meio de definir a conexão entre pontos de interesse em imagens. Normalmente, pontos de interesse são considerados como elementos independentes descritos por informação local. Tal abordagem apresenta limitações uma vez que informação local pode não ser suficiente para descrever certas regiões da imagem. Pontos de mínimo e máximo são comumente utilizados como pontos de interesse em imagens, os quais podem ser obtidos a partir dos complexos de Morse, bem como sua conectividade no espaço de imagem. Esta tese apresenta uma abordagem dirigida por algoritmos e estruturas de dados para computar o complexo de Morse discreto em imagens bidimensionais. A construção é ótima e permite fácil manipulação do complexo. Resultados teóricos e experimentais são apresentados para mostrar que o método é eficaz. Experimentos realizados incluem a computação de homologia persistente e hierarquias de complexos sobre dados de elevação de terrenos. Outra contribuição é a proposição de um operador topológico, chamado Contexto Local de Morse, computado sobre complexos de Morse, para extrair vizinhanças de pontos de interesse para explorar a informação estrutural de imagens. O contexto local de Morse é usado no desenvolvimento de um algoritmo que auxilia a redução do número de casamentos incorretos entre pontos de interesse e na obtenção de uma medida de confiança para tais correspondências. A abordagem proposta é testada em pares de imagens sintéticas e de imagens subaquáticas, para as quais métodos existentes podem obter muitas correspondências incorretas / Abstract: The Morse theory is important for studying the topology of scalar functions such as elevation of terrains and data from physical simulations, which relates the topology of a function to critical points. The smooth theory has been adapted to discrete data through constructions such as the Morse-Smale complexes and the discrete Morse complex. Morse complexes have been applied to image processing, however, there are still challenges involving algorithms and practical considerations for computation and modeling of the complexes. Morse complexes can be used as means of defining the connectedness of interest points in images. Usually, interest points are considered as independent elements described by local information. Such an approach has its limitations since local information may not suffice for describing certain image regions. Minimum and maximum points are widely used as interest points in images, which can be obtained from Morse complexes, as well as their connectivity in the image space. This thesis presents an algorithmic and data structure driven approach to computing the discrete Morse complex of 2-dimensional images. The construction is optimal and allows easy manipulation of the complex. Theoretical and applied results are presented to show the effectiveness of the method. Applied experiments include the computation of persistent homology and hierarchies of complexes over elevation terrain data. Another contribution is the proposition of a topological operator, called Local Morse Context (LMC), computed over Morse complexes, for extracting neighborhoods of interest points to explore the structural information in images. The LMC is used in the development of a matching algorithm, which helps reducing the number of incorrect matches between images and obtaining a confidence measure of whether a correspondence is correct or incorrect. The approach is tested in synthetic and challenging underwater stereo pairs of images, for which available methods may obtain many incorrect correspondences / Doutorado / Ciência da Computação / Doutor em Ciência da Computação
104

Existencia e multiplicidade de soluções para a Equação de Schrodinger não-linear em Rn / Existence and multiplicity of solutions for the non-linear Schrodinger Equation in Rn

Malavazi, Mazílio Coronel, 1983- 16 February 2007 (has links)
Orientador: Francisco Odair Vieira de Paiva, Aloisio Freiria Neves / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matemática, Estatística e Computação Científica / Made available in DSpace on 2018-08-08T02:49:07Z (GMT). No. of bitstreams: 1 Malavazi_MazilioCoronel_M.pdf: 786706 bytes, checksum: 9e4d9aae3bd0fdd46d7adf64ce8958ef (MD5) Previous issue date: 2007 / Resumo: Nesta dissertação obtemos resultados de multiplicidade de soluções fracas não triviais para o problema -Du + V (x)u = f (x; u); x 2 RN; onde V é contínua, f é C1, com f (x; 0) = 0 e f é assintoticamente linear. Utilizamos métodos variacionais e a teoria de grupos críticos, para obtermos e distinguirmos as soluções. Apresentamos também resultados de existência de solução não trivial para o problema -Du + V (x)u = f (u); x 2 RN; onde V e f são funções contínuas. Utilizamos as técnicas de concentração de compacidade e de aproximação do domínio por subconjuntos limitados, para obtermos a solução / Abstract: In this dissertation we get resulted of multiplicity of not trivial weak solutions for the problem -Du + V (x)u = f (x; u); x 2 RN; where V is continuous, f is C1, with f (x; 0) = 0 and f is asymptotically linear. We use variationals methods and the theory of critical groups, to get and to distinguish the solutions. We also present results of existence of not trivial solution for the problem -Du + V (x)u = f (u); x 2 RN; where V and f are continuous functions. We use the techniques of concentration of compactness and approximation of the domain for bounded subsets, to get the solution / Mestrado / Mestre em Matemática
105

Isomorphic chain complexes of Hamiltonian dynamics on tori

Hecht, Michael 17 July 2013 (has links)
In this thesis we construct for a given smooth, generic Hamiltonian H on the 2n dimensional torus a chain-isomorphism between the Morse complex of the Hamiltonian action on the free loop space of the torus and the Floer-complex. Though both complexes are generated by the critical points of the Hamiltonian action, their boundary operators differ. Therefore the construction of the isomorphism is based on counting the moduli spaces of hybrid-type solutions which involves stating a new non-Lagrangian boundary value problem for Cauchy-Riemann type operators not yet studied in Floer theory. It is crucial for the statement that the torus is compact, possesses trivial tangent bundle and an additive structure. We finally want to note that the problem is completely symmetric.
106

Complexe de Morse et bifurcations

Duquerroix, Florian 01 1900 (has links)
Soit une famille de couples (ft,Xt)t∈J , où J est un intervalle, ft est une fonction lisse à valeurs réelles définie sur une variété lisse et compacte V , et Xt est un pseudo-gradient associé à la fonction ft. L’objet de ce mémoire est l’étude des bifurcations subies par les complexes de Morse associés à ces couples. Deux approches sont utilisées : l’étude directe des bifurcations et l’approche par homotopie. On montre que finalement ces deux approches permettent d’obtenir les mêmes résultats d’un point de vue fonctoriel. / Let (ft,Xt)t∈J be a family of pairs, where J is an interval, ft is a smooth real-valued Morse function defined on a smooth compact manifold V , and Xt is a pseudo-gradient field associated to ft. The purpose of this master thesis is to study the bifurcations undergone by the associated Morse complexes. Two ways are used to reach this result : the direct study of the bifurcations and the continuation method. We prove that the two methods produce the same results from a functorial point of view.
107

O uso do Mini-BESTest e da Morse Fall Scale na avaliação do risco de quedas durante a internação e no pós alta de pessoas idosas / The use of the Morse Fall Scale and Mini-BESTest to evaluate risk identification of falls during hospitalization and post-hospital discharge in elderly

Silva, Deise Ferreira da 26 April 2019 (has links)
Introdução: As quedas hospitalares interferem na funcionalidade do paciente durante e após a hospitalização. Nosso objetivo foi verificar se uma escala de identificação do risco de quedas (Morse Fall Scale) e um teste de avaliação de equilíbrio dinâmico (Mini-BESTest) identificam os idosos caidores durante e após hospitalização. Método: Trata-se de um estudo coorte prospectivo com análise retrospectiva. Participaram 154 idosos (>=65 anos) internados em duas enfermarias não cirúrgicas de Clínica Médica e Geriatria de um Hospital Universitário de porte extra. Foram realizadas avaliações do Mini-BESTest e da Morse Fall Scale (MFS) na admissão e na alta hospitalar. O acompanhamento das quedas foi feito por telefone em 1, 3 e 6 meses após alta hospitalar. Resultados: Os idosos foram divididos em: caidores (Grupo Q, n=5) e não caidores (Grupo NQ, n=149) na hospitalização. Na admissão não houve diferença significativa entre os Grupos Q e NQ nas ferramentas avaliadas (Mini-BESTest Q=23, NQ=20, p=0.85; MFS Q=25, NQ=15, p=0,87) e na alta hospitalar apenas na MFS (Mini-BESTest Q=20, NQ=22, p=0,22; MFS Q=50, NQ=25, p=0,01). Nos domínios \"Respostas Posturais\" do Mini- BESTest e nos domínios \"Histórico de Quedas\" e \"Tipo de Marcha\" da MFS houve diferença entre Q e NQ na alta (respectivamente, =0,02; p=0,01; p=0,02). Foi realizada uma subanálise com pareamento de dados por gênero, idade e comorbidades e também não foram encontradas diferenças clínicas, demográficas e nos escores das escalas entre os grupos Q (n=5) e NQp (n=10) (p > 0,05). Na predição de quedas pós-alta o Mini-BESTest apresentou AUC=0,53, p=0,50, sensibilidade 48,8% e especificidade 59,5%, já a MFS apresentou AUC=0,56, p=0,20, sensibilidade 44,2% e especificidade 72%. Houve um aumento de caidores nos 6 meses de Follow-up (11,2%, 15,6% e 17,1%;), e os pacientes com baixo risco de queda pela MFS tiveram mais quedas no Follow-up do que os pacientes de alto risco. Conclusão: Mini-BESTest e a Morse Fall Scale não identificaram os idosos caidores durante e após a hospitalização, apesar de alterações nos domínios na alta hospitalar e do aumento de quedas no Follow-up / Introduction: Hospital falls interfere with the patient\'s functionality during and after hospitalization. This study aimed to identify whether the Morse Fall Scale and Mini-BESTest can identify fall risk in elderly patients during and after hospitalization. Method: This is a prospective cohort study with retrospective analysis. A total of 154 consecutive elderly patients (>=65 years old) who were hospitalized at two clinical wards in a tertiary Hospital were included in the study. Mini-BESTest and Morse Fall Scale (MFS) assessments were carried out at hospital admission and discharge. The occurrence of falls was evaluated by phone calls 1, 3 and 6 months after hospital discharge. Results: Patients were divided in two groups, those who had falls (F group, n=5) and those who did not fall (NF group, n=149) during hospitalization. At hospital admission, no differences were observed between the F and NF groups in the Mini-BESTest (F=23 vs. NF=20; p=0.85) and MFS (F=25 vs. NF=15; p=0.87) scores. At hospital discharge, the F and NF groups had similar scores in the Mini-BESTest (F=20 vs. NF=22; p=0.22) but differences in the MFS (F=50 vs. NF=25; p=0.01). The domain assessments for \"postural responses\" of the Mini-BESTest and \"history of falls\" and \"type of gait\" of the MFS were different between the F and NF groups at hospital discharge (p=0.02, p=0.01 and p=0.02, respectively). A sub analysis was performed with data matching by gender, age and comorbidities and no clinical, demographic and scales differences were observed between the group F (n=5) and group NFm (n=10) (p > 0.05). In the prediction of post-discharge falls, the Mini-BESTest presented AUC = 0.53, p = 0.50, sensitivity 48.8% and specificity 59.5%, the MFS presented AUC=0.56, p=0. 20, sensitivity 44.2% and specificity 72%. There was an increase in the number of patients who fell from the 1st to the 6th month of follow-up (from 11.2% to 17.1%), and the patients with low and medium fall risk determined by the MFS had more falls in the follow-up period than those classified as high risk. Conclusion: Our results suggest that neither the Mini-BESTest nor the MFS identified elderly fall risk during and after hospitalization. In addition, we observed the need to supervise elderly patients after hospitalization
108

Problemas parabólicos em materiais compostos unidimensionais: propriedade de Morse Smale. / Parabolic problems in unidimensional composite materials: Morse-Smale property.

Carbone, Vera Lucia 07 March 2003 (has links)
Neste trabalho estudamos problemas de reação difusão em domínios unidimensionais que surgem de materiais compostos e obtemos resultados comparando os fluxos do problema original e do problema limite quando a difusão fica muito grande em partes do domínio. Provamos que os autovalores e autofunções do operador linear ilimitado associado à equação limite têm a propriedade de Sturm Liouville e provamos que as soluções do problema de reação difusão têm a propriedade do decrescimento do número de zeros ao longo do tempo. Estes resultados são usados para provar que as variedades instável e estável de pontos de equilíbrios são genericamente transversais e que o fluxo no atrator para o problema de reação difusão é genericamente estruturalmente estável. Estes fatos permitem obter a equivalência topológica dos fluxos restritos aos atratores dos problemas original e seu problema limite. / In this work we study some reaction-difusion problems in one dimensional domains that arise from composite materials. We obtain some results comparing the flux of the original problem and the flux of the limit problem when the difusion becomes large on parts of the physical domain. We prove that the eigenvalues and eigenfunctions of the linear unbounded operator associated with the equation have the Sturm Liouville property and also that the solutions of the reaction difusion equation have the property that the zeros do not increase with time. These results are used to obtain that the stable and unstable manifolds of equilibrium points are generically transversal and that the flux on the attractor for the reaction difusion problem is generically structurally stable. Using this we are able to prove the topological equivalence of the fluxs restricted to the attractors of the original and the limit problem.
109

Análise fotoelástica das tensões geradas por diferentes planejamentos de próteses parciais fixas parafusadas sobre implantes cone morse / Photoelastic analyses of stress generated by different designs of screw-retained fixed partial denture on morse taper implants

Torres, Érica Miranda de 01 July 2008 (has links)
A restauração protética deve receber e transmitir cargas funcionais aos implantes de forma controlada, a fim de minimizar a ocorrência de falhas mecânicas e biológicas. A concentração de tensões inadequadas na interface osso-implante pode provocar reabsorção óssea em torno dos implantes em níveis superiores aos considerados clinicamente aceitáveis. Não existe consenso na literatura quanto ao melhor planejamento protético para reabilitações parciais com múltiplos implantes adjacentes, a fim de minimizar as tensões geradas na interface osso-implante. A fotoelasticidade é uma técnica experimental para análise de tensões, bastante empregada devido à sua relativa simplicidade e confiabilidade quanto à correspondência clínica dos achados observados. O presente trabalho se propôs a avaliar, por meio de análise fotoelástica, o comportamento biomecânico de próteses parciais fixas parafusadas sobre implantes cone morse com coroas isoladas ou unidas, simulando a reabilitação de áreas posteriores com e sem a presença de elemento dental distal aos implantes, e ainda variando o tipo de material de recobrimento estético empregado na restauração protética (cerâmica ou resina), quando sobre estas próteses foram aplicadas diferentes tipos de cargas estáticas. Para tanto, foi confeccionado um modelo fotoelástico simulando um espaço protético intercalado, com ausência do segundo prémolar e primeiro molar, reabilitado por meio de quatro tipos de coroas parafusadas sobre dois implantes cone morse (Neodent) adjacentes: UC - coroas unidas com recobrimento estético em cerâmica; IC - coroas isoladas com recobrimento estético em cerâmica; UR - coroas unidas com recobrimento estético em resina; IR - coroas isoladas com recobrimento estético em resina. A adaptação marginal das coroas foi avaliada pela leitura dos desajustes verticais na interface coroa/pilar em microscópio ótico. Análise fotoelástica qualitativa foi realizada sob diferentes condições de aplicação de carga na superfície oslusal das coroas: oclusal distribuída (1kgf), puntiforme simultânea (1kgf), puntiforme alternada no molar e no pré-molar (0,5kgf). A primeira análise foi feita na presença de contato proximal efetivo entre as próteses e o dente a distal dos implantes. A segunda análise foi realizada após eliminar a coroa do dente distal no modelo fotoelástico. Registros fotográficos foram obtidos de cada situação de interesse para análise, a fim de facilitar a observação e comparação do padrão de distribuição das franjas isocromáticas em torno dos implantes. De acordo com os resultados obtidos pode-se concluir que a ferulização das coroas promoveu melhor distribuição de tensões em torno dos implantes. As restaurações metalocerâmicas resultaram em menor magnitude e concentração de tensões em torno dos implantes quando comparadas às restaurações metaloplásticas. A presença de um dente com ponto de contato efetivo na distal das coroas não modificou as tensões resultantes em torno dos implantes, mas este dente participou da distribuição de tensões para o modelo fotoelástico. A ausência de uma oclusão bem ajustada e distribuída sobre as restaurações protéticas pode provocar sobrecarga nos implantes. / Prosthetic restoration should suffer and apply functional loads over implants in a controlled way with the aim to reduce the occurrence of mechanical and biological failures. The concentration of inadequate stress on the implant-bone interface may cause bone resorption around implants at levels above those considered clinically acceptable. There is no consensus in the literature about the best prosthetic plan for partial rehabilitation with multiple adjacent implants, with the aim to reduce the stress generates over the implantbone interface. Photoelasticity is an experimental technique used to analyzes stress and is highly used due to its relative simplicity and reliability in terms of the clinical agreement of the findings. The purpose of the present study was to assess, using photoelastic analysis, the biomechanical behavior of screwretained fixed partial dentures on morse taper implants with individual or connected crowns, simulating the rehabilitation of posterior areas with or without the presence of a dental element distal to the implants. Furthermore, the analyses considered different esthetic materials used in prosthetic restorations (ceramic or resin), and different static loads were applied over the prostheses. To do this, a photoelastic model was fabricated simulating the missing of the second pre-molar and the first molar. The model was rehabilitated through four types of screw-retained crowns over two adjacent morse taper implants (Neodent): CC connected crowns with ceramic esthetic overlay; IC individual crowns with ceramic esthetic overlay; CR connected crowns with resin esthetic overlay; - IR - individual crowns with resin esthetic overlay. The crowns marginal fit was assessed by reading the vertical misfits on the crownabutment interface using an optic microscope. The qualitative photoelastic analysis was performed under the application of different loads on the crowns occlusal surface: distributed occlusal (1kgf), simultaneous punctiform (1kgf), alternate punctiform over the molar and pre-molar (0.5 kgf). The first analysis was done with an effective proximal contact between the prostheses and the distal tooth. The second analysis was performed after eliminating the crown of the distal tooth in the photoelastic model. Photoelastic records were obtained in each situation that was of any interest to the analysis, with the aim to make it easy to observe and compare the distribution standard of the isochromatic fringes around the implants. According to the obtained results, it is concluded that crown splint promoted better stress distribution around the implants. The metallo-ceramic restorations resulted in less magnitude and stress concentration around the implants compared to metaloplastic restorations. The presence of one tooth with an effective contact point on the crown distal did not change the resulting stress around the implants, but that tooth took part in the stress distribution for the photoelastic model. A bad distributed occlusion over the prosthetic restorations can cause overload on the implants.
110

Um invariante para sistemas com integral primeira Morse-Bott / A invariant for systems with a Morse-Bott first integral

Sarmiento, Ingrid Sofia Meza 16 August 2011 (has links)
Nesta dissertação são investigados os sistemas diferenciais com integral primeira do tipo Morse-Bott definidos em superfícies compactas e orientáveis. A cada sistema, nas condições acima descritas, associa-se um grafo de modo que a correspondência entre os grafos e as classes de equivalência topologica orbital dos campos investigados seja bijetiva. Portanto, apresenta-se um invariante completo, chamado aqui de grafo de Bott, para essa classe de sistemas. Essa abordagem surgiu como uma iniciativa de generalizar o estudo realizado para sistemas Hamiltonianos com um grau de liberdade com integral primeira do tipo Morse definidos em superfícies 2-dimensionais compactas, onde os conceitos de átomos e fluxos gradiente foram aplicados por A.V. Bolsinov em [4] / In this dissertation are studied differential systems with a Morse-Bott first integral defined on compact orientable surfaces. For each system, under the conditions described above, is associated a graph so that the correspondence between graphs and the orbital topological equivalence classes of the systems are bijective. Therefore, we present a complete invariant, called here Bott graph for this class of systems. This approach has emerged as an initiative to generalize the study to systems Hamiltonian with one degree of freedom having a Morse first integral in 2-dimensional compact surfaces, where the concepts of atoms and gradient flows were applied by A.V. Bolsinov in [4]

Page generated in 0.0609 seconds