• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 311
  • 40
  • 40
  • 39
  • 39
  • 24
  • 16
  • 6
  • 6
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 314
  • 314
  • 99
  • 73
  • 56
  • 46
  • 40
  • 39
  • 35
  • 35
  • 34
  • 34
  • 33
  • 32
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Avaliação da radiopacidade, do pH e da atividade antimicrobiana do MTA, do cimento Portland puro e do cimento Portland adicionado de agentes radiopacificadores

Lima, Marta Judite Nunes 26 February 2016 (has links)
Introduction: The radiopacity is a required property in all dental materials. This characteristic allows this materials be able to be distinguished from the tooth surfaces through the radiography. Portland cement (PC) presents physico-chemical and biological properties similar to mineral trioxide aggregate (MTA), except for radiopacifier. Objective: To evaluate the radiopacity, antimicrobial activity and pH of the MTA, pure PC and PC added different radiopacifiers. Materials and Methods: The radiopacity of MTA, pure PC and PC added the radiopacifying: iodoform, lead oxide, zirconium oxide, bismuth subnitrate, barium sulfate and bismuth oxide in the proportions 15%, 20% and 30% were analyzed. The radiopacity was carried out using a semi-direct digital radiography system (Instrumentarium Kavo EXPRESS®). The PC and cements selected with adequate radiopacity (ANSI/ADA No. 57) were evaluated for their antimicrobial activity and pH. Antimicrobial activity was analyzed by microdilution tests and agar diffusion. The microorganism tested were Enterococcus faecalis, as a standard strain (ATCC 29212) and six clinical strains (LMA 26, LMA 27, LMA 28, LMA 29, LMA 31 and LMA 34). The pH was measured using a digital pH meter (pH Meter Pocket-sized). Statistical analyzes were performed using the Shapiro-Wilk normality test, ANOVA and Tukey with significance level of 5%. Results: Pure PC had the lowest radiopacity. The MTA, PC + iodoform 20% (3.59 mmEq.Al), PC + bismuth oxide 20% (4.79 mmEq.Al), PC + bismuth subnitrate 20% (3.12 mmEq.Al), PC + 20% lead oxide (3.18 mmEq.Al) and PC + 30% zirconium oxide (4.28 mmEq.Al). Regarding the agar diffusion test, the LMA 26 strain was inhibited by PC, PC + Iodoform 20%, PC + 30% Zirconium Oxide, PC + Bismuth subnitrate 20%, and PC + Bismuth Oxide 20%. The LMA 31 strain was inhibited by PC + zirconium oxide 30% and PC + bismuth subnitrate 20% and LMA 27 strain was inhibited by PC + bismuth subnitrate 20%. The other strains were not inhibited. In the microdilution test, most strains was inhibited by tested materials, except the ATCC 29212 strain which was not inhibited by PC + lead oxide 20%. LMA 28 29, 31 and 34 strains were not inhibited by PC + lead oxide 20%and PC + zirconium oxide 30%, in which LMA 28 and 29 strains were not inhibited by PC + bismuth oxide20%. All cements tested showed alkalinity in all experimental periods, in which MTA had the lowest pH. Conclusions: MTA and PC added the radiopacifiers subnitrate bismuth and iodoform in concentrations of 20% by weight, provided satisfactory radiopacity, alkaline medium and promoted bactericidal and bacteriostatic activities against strains of E .faecalis tested. / Introdução: A radiopacidade é uma propriedade obrigatória em todos os materiais odontológicos. Esta característica permite este material seja distinguido das superfícies dentárias através da radiografia. O cimento Portland (CP) apresenta propriedades físicoquímicas e biológicas semelhantes ao Agregado Trióxido Mineral (MTA), exceto pela partícula radiopacificadora. Objetivo: Avaliar a radiopacidade, atividade antimicrobiana e pH do MTA, CP puro e CP adicionado de diferentes radiopacificadores. Materiais e Métodos: Foi analisada a radiopacidade do MTA, CP e CP adicionado dos radiopacificadores: iodofórmio, óxido de chumbo, óxido de zircônio, subnitrato de bismuto, sulfato de bário e óxido de bismuto nas proporções 15%, 20% e 30%. A radiopacidade foi avaliada por meio do sistema de radiografia digital semi-direto (Instrumentarium Kavo EXPRESS®). O CP e os cimentos selecionados com radiopacidade adequada (ANSI/ADA nº 57) foram submetidos à avaliação da atividade antimicrobiana e do pH. A atividade antimicrobiana foi analisada pelos testes de microdiluição e difusão em ágar. O micro-organismo testado foi o Enterococcus faecalis, sendo uma cepa padrão (ATCC 29212) e seis cepas clínicas (LMA 26, LMA 27, LMA 28, LMA 29, LMA 31 e LMA 34). O pH foi aferido com pHmetro digital (pH Meter Pocket-sized). Os testes estatísticos utilizados foram os testes Shapiro-Wilk de normalidade, análise de variância ANOVA e Tukey a nível de significância de 5%. Resultados: O CP puro apresentou o menor valor de radiopacidade, O MTA, CP + iodofórmio 20% (3,59 mmEq.Al), CP + óxido de bismuto 20% (4,79 mmEq.Al), CP + subnitrato de bismuto 20% (3,12 mmEq.Al), CP + óxido de chumbo 20% (3,18 mmEq.Al) e CP + óxido de zircônio 30% (4,28 mmEq.Al). No teste de difusão em ágar, a cepa LMA 26 foi inibida pelo CP, CP + Iodofórmio 20%, CP + Óxido de Zircônio 30%, CP + Subnitrato de Bismuto 20% e CP + Óxido de Bismuto 20%. A cepa LMA 31 foi inibida pelas associações CP + óxido de zircônio 30% e CP + subnitrato de bismuto 20% e a cepa LMA 27 foi inibida pelo CP + subnitrato de bismuto 20%. As demais cepas não foram inibidas. No teste de microdiluição, a maioria das cepas foi inibida pelos materiais-testes, exceto a cepa ATCC 29212 que não foi inibida pelo CP + óxido de chumbo 20%, as cepas LMA 28, 29, 31 e 34 não foram inibidas pelas associações CP + óxido de chumbo 20% e CP + óxido de zircônio 30%, sendo que as cepas LMA 28 e 29 também não foram inibidas pelo CP + óxido de bismuto 20%. Todos os cimentos testados apresentaram alcalinidade em todos os períodos experimentais, sendo que o MTA apresentou os menores valores de pH. Conclusões: O MTA e as concentrações de CP adicionado de 20% do agente radiopacificador subnitrato de bismuto e CP adicionado do agente radiopacificador iodofórmio, 20% em peso, proporcionaram radiopacidade satisfatória, alcalinizaram o meio e promoveram atividades bactericida e bacteriostática contra as cepas de E. faecalis testadas.
302

Cultura de osteoblastos sobre arcabouço da blenda de PCL/PLGA : estudo in vitro e in vivo / Osteoblasts culture on PCL/PLGA blend scaffold : in vintro and in vivo study

Silva, Katia Fernanda 14 August 2018 (has links)
Orientador: Eliana Aparecida de Rezende Duek / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T20:10:35Z (GMT). No. of bitstreams: 1 Silva_KatiaFernanda_M.pdf: 16700696 bytes, checksum: 568261b128b361204100ac55aba7640b (MD5) Previous issue date: 2008 / Resumo: A Ciência dos Biomateriais é uma área de conhecimento multidisciplinar e está relacionada a implantes cirúrgicos e dispositivos médicos e odontológicos. Dentre as atuais aplicações dos biomateriais, a utilização de polímeros biorreabsorvíveis como arcabouço (scaffolds) para cultura de células tem se destacado como alternativa para tratamento de lesões e perda de tecidos. O objetivo deste trabalho foi obter e caracterizar arcabouços da blenda de poli(e-caprolactona) (PCL) e poli(D,L-ácido lático-co-ácido glicólico) (PLGA) nas diferentes composições (70/30, 50/50 e 30/70), preparados pelo método de fusão com adição e lixiviação de citrato de sódio. Os resultados obtidos através das análises de MEV evidenciaram que as amostras da blenda de PCL/PLGA 30/70 possuem tamanhos e quantidades de poros mais homogêneos quando comparadas às suas análogas de PCL/PLGA nas composições 50/50 e 70/30. Os materiais foram utilizados como arcabouço para cultura de osteoblastos e o estudo in vivo foi realizado pelo implante em tíbia de ratos. A cultura de células nas blendas de PCL/PLGA 70/30 e 30/70 mostraram um padrão de adesão e proliferação satisfatório, com intensa atividade celular comparado com a blenda na composição 50/50. No estudo in vivo as amostras de PCL/PLGA 30/70 com cultura apresentaram um crescimento celular mais intenso quando comparada com as blendas nas composições 70/30 com cultura, e nas diferentes composições sem cultura de células. Os resultados mostraram que a técnica utilizada no preparo das amostras é útil na confecção de arcabouços altamente porosos. Em função das análises in vitro e in vivo as blendas de PCL/PLGA 30/70 foram os arcabouços mais indicados para aplicações na engenharia de tecidos ósseos. / Abstract: The use of bioreabsorbable polymers as scaffolds for the cells culture has received special attention as an alternative for the treatment of lesions and the loss of tissue. The aim of this work was to obtain and to characterize porous scaffolds of poly(e-caprolactone) (PCL) and poly(D,Llactic acid-co-glycolic acid) (PLGA), blends, in different composition (30/70, 50/50 e 70/30), prepared by melting method with addition and leaching of sodium citrate. The morphology of samples obtained by SEM showed that PCL/PLGA 30/70 blends presented size and size distribution of porous more homogeneous when compared to PCL/PLGA 50/50 and 30/70. The culture of cells in PCL/PLGA 70/30 and 30/70 showed a satisfactory adhesion and proliferation, with intense cellular activity compared to PCL/PLGA 50/50. In the in vivo study, the samples of PCL/PLGA 30/70 showed a higher cellular grown compared to the results obtained in in vivo study of 70/30 blends with cells, 70/30 and 30/70 without cells. The results showed that the proposed technique allowed the preparation of highly porous scaffolds and the in vitro and in vivo showed that PCL/PLGA 30/70 blends were the most suitable scaffolds for applications in the bone tissue engineering. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
303

Deformação plástica a frio, transformações de fases e propriedades mecânicas de ligas Ti-Nb-Sn para uso biomédico / Cold deformation, phases transformations and mechanical strength of Ti-Nb-Sn alloys for biomedical uses

Cremasco, Alessandra, 1983- 21 August 2018 (has links)
Orientador: Rubens Caram Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-21T09:06:40Z (GMT). No. of bitstreams: 1 Cremasco_Alessandra_D.pdf: 50106196 bytes, checksum: 2a7da86acd168979590189fcdb26056f (MD5) Previous issue date: 2012 / Resumo: Ligas de titânio com altos teores de elementos _ estabilizadores, solubilizadas em altas temperaturas e resfriadas rapidamente exibem limitada resistência mecânica e boa ductilidade, o que e resultado da formação de martensita ortorrômbica ou da manutenção da fase _ metaestável. Tal resistência pode ser significativamente aumentada por meio da aplicação de tratamentos térmicos de envelhecimento, que promovem a precipitação de novas fases, combinados com encruamento produzido por deformação plástica a frio. Este trabalho teve como objetivo o desenvolvimento de ligas do sistema Ti-Nb-Sn com propriedades mecânicas otimizadas visando sua utilização como biomaterial. Inicialmente, ligas de titânio com diferentes elementos de liga foram submetidas a ensaios de citocompatibilidade in vitro. Os resultados obtidos sugerem que ligas Ti-Nb-Sn sao biocompativeis. Na sequencia, amostras de ligas Ti-Nb-Sn preparadas em forno de fusao a arco foram tratadas termicamente objetivando homogeneizacao quimica e microestrutural, solubilizadas em alta temperatura, resfriadas rapidamente e deformadas plasticamente a frio. Tais amostras foram tratadas termicamente para promover a recuperacao, a recristalizacao e o envelhecimento da microestrutura. Os resultados obtidos indicam que a aplicacao de deformacao plastica e recozimento produz o refinamento da microestrutura. A aplicacao de tratamentos termicos de envelhecimento a 350 °C resultou na decomposicao da fase martensita ortorrombica e na formacao das fases _, w e a. Constatou-se que o comportamento mecanico das amostras envelhecidas reflete a combinacao das fases e suas respectivas fracoes volumetricas. O refino microestrutural e a precipitação da fase a resultaram em expressivo aumento da dureza, modulo de elasticidade e resistencia mecanica, bem como na queda da ductilidade. Finalmente, a aplicacao de condicoes de processamento otimizadas resultou em amostras com elevada resistencia mecanica e razoavel ductilidade. A liga Ti-35Nb-4Sn apresentou reduzido modulo de elasticidade e alta resistencia a tracao, condicao ideal para aplicacao biomedica / Abstract: Titanium alloys with high _ stabilizing elements content, solution heat treated at high temperatures and rapidly cooled to room temperature, exhibit limited mechanical strength and good ductility as a result of orthorhombic martensite formation or maintenance of the _ metastable phase. However, mechanical strength may be significantly improved by applying aging heat treatment, which leads to precipitation of new phases, combined with hardening provided by cold plastic deformation. The aim of this work is the development of alloys in the Ti-Nb-Sn system with optimized mechanical properties to be applied as biomaterial. Initially, titanium alloys with different alloying elements were tested in terms of cytocompatibility. The results suggest that Ti-Nb-Sn alloys are biocompatible. Following, Ti-Nb-Sn samples were prepared in arc furnace, heat treated aiming chemical and microstructural homogeneity, solution heat treated at high temperature, rapidly cooled to room temperature and cold plastically deformed. These samples were heat treated to promote recovery, recrystallization and aging of the microstructure. The results indicate that application of plastic deformation and annealing produces very refined microstructure. Application of aging heat treatments at 350 ° C resulted in decomposition of orthorhombic martensite phase and formation of _, w and a phases. It was found that mechanical properties of aged samples reflect the combination of such phases and their volume fractions. Microstructural refinement and a phase precipitation resulted in significant increase in hardness, elastic modulus and mechanical strength, as well as a decrease in ductility. Finally, application of optimal processing conditions resulted in samples with high mechanical strength and reasonable ductility. The Ti-35Nb-4Sn alloy showed lower elastic modulus and superior tensile strength. These results consist in ideal conditions for biomedical applications / Doutorado / Materiais e Processos de Fabricação / Doutora em Engenharia Mecânica
304

Preparo e avaliação de compósitos contendo nova matriz inorgânica monomodal submicrométrica / Preparation and evaluation of new inorganic matrix composites containing submicron monomodal

Valente, Lisia Lorea 17 May 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-17 / In this study dental composites containing a novel monomodal inorganic matrix based on submicron Ba-Al-Si glass particles (NanoFine NF180, Schott) were prepared and evaluated. Composites with particles of similar composition but micron-sized (UltraFine UF1.0, Schott) served as a reference. The study was carried out in two phases: (i) characterization of the inorganic particles, involving x-ray microanalysis and granulometry; (ii) preparation and characterization of micron and submicron composites involving analysis of the morphology of the composites and measurements of radiopacity, degree of C=C conversion, hardness, flexural strength and modulus, work-of-fracture, surface roughness and gloss before and after toothbrushing abrasion and compressive creep. The composites were formulated from the same co-monomer based on Bis-GMA, Bis-EMA8, UDMA and TEGDMA at a 7:7:5:1 (w/w) ratio, with photoinitiators added. A mass of 75% of micron and 78% of submicron particles were incorporated based on pilot studies. Quantitative data restricted to direct comparisons between the composites were analyzed using t-tests. Roughness and gloss data for the comparison between the composites before and after toothbrushing were submitted to Repeated Measures Analysis of Variance and Student-Newman-Keuls test (5%). Both inorganic systems showed narrow grain size range (175±30 and 1000±200nm), with differences restricted to the size and specific area of the particles, which determined differences in the amount of silane used (13% for submicron and 3.2% for micron particles). Particles from both systems were homogeneously dispersed in the resin phase, although the submicron particles occupied larger area of the material s surface. The composites showed statistically similar results for radiopacity, flexural strength, work-of-fracture, and creep. The submicron composite had significantly higher hardness than the micron composite, whereas significantly lower flexural modulus and C=C conversion. No significant differences in roughness between the composites were observed before toothbrushing, while the submicron composite showed significantly higher gloss. The abrasion increased significantly the roughness and reduced the gloss of both materials. Surface roughness was still similar and the gloss of the submicron composite significantly higher after toothbrushing. In conclusion, the monomodal submicron glass filler system tested showed potential for application in the development of restorative dental composites, especially because of the esthetic properties compared with the micron system / Neste estudo, foram preparados e avaliados compósitos odontológicos contendo nova matriz inorgânica monomodal baseada em partículas de vidro de Ba-Al-Si (NanoFine NF180, Schott) de tamanho submicrométrico. Compósitos contendo partículas de composição similar, porém tamanho micrométrico (UltraFine UF1.0, Schott), foram testados como referência. O estudo se desenvolveu em duas fases: (i) caracterização de partículas inorgânicas, envolvendo microanálise de raios-x e granulometria; (ii) obtenção e caracterização de compósitos micro e submicrométricos envolvendo análise da morfologia dos compósitos preparados e determinação da radiopacidade, grau de conversão de C=C, dureza, resistência e módulo de flexão, trabalho de fratura, rugosidade e brilho da superfície antes e após desgaste por abrasão e escoamento compressivo (creep). Os compósitos foram formulados a partir do mesmo co-monômero baseado em Bis-GMA, Bis-EMA8, UDMA e TEGDMA, na razão 7:7:5:1 (m/m), ao qual fotoiniciadores foram adicionados. Foi acrescentada massa de 75% do sistema micrométrico e 78% do submicrométrico, com base em estudos-piloto. Os dados quantitativos restritos à comparação direta entre os compósitos foram analisados utilizando testes-t. Os dados de rugosidade e brilho na comparação dos compósitos antes e após a escovação foram submetidos à Análise de Variância para Medidas Repetidas e teste de Student-Newman-Keuls (5%). Ambos sistemas inorgânicos apresentaram estreita faixa do tamanho de grão (175±30 e 1000±200nm), com diferenças entre as partículas restritas ao tamanho e área específica, o que determinou diferença na quantidade de silano utilizada (13% para submicrométricas e 3,2% para micrométricas). As partículas de ambos sistemas foram dispersas de forma homogênea na matriz resinosa, embora as submicrométricas ocuparam maior área da superfície do material. Os compósitos apresentaram resultados estatisticamente similares para radiopacidade, resistência à flexão, trabalho de fratura e escoamento compressivo. O compósito submicrométrico apresentou dureza significativamente superior ao material micrométrico, enquanto módulo de elasticidade e grau de conversão foram significativamente menores. Não foi observada diferença significativa na rugosidade entre os compósitos antes da escovação, enquanto o compósito submicrométrico mostrou brilho significativamente maior. A abrasão aumentou significativamente a rugosidade e reduziu significativamente o brilho de ambos materiais. A rugosidade continuou estatisticamente similar e o brilho do compósito submicrométrico significativamente maior após a abrasão. Em conclusão, o sistema monomodal submicrométrico de carga de vidro testado apresentou potencial de utilização no desenvolvimento de compósitos restauradores odontológicos, especialmente em função de suas propriedades estéticas comparadas ao sistema micrométrico
305

Membrana amniótica descelularizada como substituto dérmico no processo de regeneração de queimaduras / Amniotic decellularized membrane as a dermal subistitute in the regeneration process of burn

Doi, Songila Maria da Silva Rocha 27 November 2015 (has links)
A queimadura de 3º grau é um dos maiores traumas a que um ser humano pode ser submetido e em geral são as lesões mais frequentes na população mundial, tratando-se de um importante problema de saúde pública. Pensando neste problema, observou-se que a utilização da membrana amniótica (MA) pode ser o melhor tratamento que esses pacientes possam receber. Ela atua em benefício da epitelização, facilita a migração e a adesão das células epiteliais basais, a matriz estromal possui inibidores de proteases que previne a apoptose e restaura o fenótipo epitelial, antibacteriana do córion e âmnion, além de proteger a ferida e atuar na redução da dor. A descelularização, trata-se da retirada de todas as células e núcleo da MA utilizada, como forma de se evitar qualquer tipo de histoincompatibilidade. O presente trabalho teve como objetivo avaliar a eficácia do uso da membrana amniótica descelularizada (MAD) no tratamento de queimaduras de 3o grau em humanos, testada em ratos da linhagem Wistar. Trata-se de uma pesquisa descritiva, a qual investiga fundamentalmente a especificação e a disposição de dados acerca dos resultados obtidos a partir de um processo regenerativo de queimaduras utilizando-se a MAD. A amostra foi constituída de constituída por 20 ratos machos adultos da linhagem Wistar, dividida em 2 grupos (n=10): grupo controle (GC)–sem MA e grupo transplantado–com MA (TMAD). Os dois grupos foram submetidos a um processo padronizado de queimadura térmica, sendo retiradas duas amostras de tecido para análise, no 14º dia e no 30º dia. As amostras foram analisadas com o emprego de técnicas anatomopatológicas onde foram montadas em lâminas fragmentos de MA corados com solução Hematoxilina Eosina (HE) e, para análise histomorfométrica,as lâminas foram coradas com picro sirius red sob luz polarizada para verificação da descelularização e quantificação de colágeno do tipo I, II e III. As imagens foram quantificadas utilizando o programa Image Pro Plus®, versão 5.0 para Windows®. Os dados estatísticos foram analisados utilizando o programa computacional SSPS v.21.0. Observou-se um aumento significativo da quantificação de colágenos do tipo III no 14º dia no grupo TMAD em relação ao GC, do colágeno do tipo II no 14º e 30º dia comparado ao GC e do colágeno tipo I no 14º e 30º dia, mostrando que a utilização da MA foi eficaz no grupo TMAD. Concluiu-se que a MAD, aplicada topicamente, demonstrou eficácia no processo cicatricial em queimaduras de 3º grau. Esperava-se que a mesma promovesse a aceleração de cicatrização dos ferimentos, mas, o que se observou ao término do trabalho é que a MAD não só promoveu a cicatrização como foi mais eficiente no processo de regeneração dos tecidos lesados. / 3rd degree of burns are one of the greatest injury that a human being can be submitted and generally are the most frequent injuries in the world population, in the case of a major public health problem. Thinking this problem, it has been observed that the use of amniotic membrane (AM) may be the best treatment these patients can receive. It acts on behalf of epithelialization, facilitates migration and adhesion of basal epithelial cells, stromal matrix has protease inhibitors which prevent apoptosis and restores epithelial, antibacterial phenotype of the chorion and amnion, and protect the wound and act on reducing pain. The decellularization, it is the withdrawal of all cells and core AM used as a way to avoid any kind of histoincompatibility. This study aimed to evaluate the efficacy of the decellularized amniotic membrane (DAM) in the treatment of third degree burns in humans, tested in Wistar rats. It is a descriptive research which investigates mainly the specification and the arrangement of data on the results obtained from a regenerative process burns using DAM. The sample consisted of consisted of 20 Wistar adult male rats, divided into 2 groups (n = 10): control group (CG) - without MA, and group transplanted - with AM (TDAM). The two groups were submitted to a standard process of thermal burn, two samples being removed tissue for analysis on day 14 and day 30. Samples were analyzed with the use of pathological techniques which were mounted on slides DNA fragments stained with solution hematoxylin eosin (HE) for histomorphometric analysis, the slides were stained with picrosirius red under polarized light for verification of decellularization and quantifying collagen type I, II and III. Images were quantified using Image Pro Plus ®, version 5.0 for Windows. Statistical data were analyzed using the computer program SPSS v.21.0. There was a significant increase in type III collagen quantification on the 14th day in TDAM group compared to CG, type II collagen in the 14th and 30th day compared to the CG and type I collagen in the 14th and 30th day, showing that the use of MA were effective in TDAM group. It was concluded that the DAM, applied topically, has shown efficacy in the healing process in 3rd degree burns. It was expected that it would promote accelerated wound healing but which was observed at the end of work that MAD is not only promoted as the healing was more efficient the regeneration process of the damaged tissues.
306

Desenvolvimento de um biosensor para mensuração de deformações mecânicas em tecidos ósseos

Karam, Leandro Zen 21 May 2015 (has links)
CNPQ / O presente trabalho tem como objetivo o desenvolvimento de um biosensor, utilizando redes de Bragg em fibras óticas, capaz de mensurar deformações em tecido ósseo. Inicialmente foram realizados testes de esterilização e desinfecção com sensores, após o processo completo, os sensores foram testados quanto a sua sensibilidade. Com isso os métodos de esterilização e desinfecção autoclave, óxido etileno, hipoclorito de sódio, cloramina T e ácido peracético, foram eficazes para eliminação e ou inativação dos microrganismos, sem que haja alterações no comportamento das FBGs. Com isso definem-se métodos aplicáveis para possíveis estudos, onde fibras óticas foram implantadas em animais in vivo para estudos de comportamento metabólico com a presença de materiais inorgânicos. Na continuidade dos trabalhos foram realizados testes de compatibilidade de fibras óticas inseridas no tecido subcutâneo de ratos. Baseado na análise descritiva dos cortes histológicos pode-se concluir que as fibras ópticas sem revestimento e com revestimento foram biocompatíveis quando implantadas em subcutâneo de ratos. Sendo assim, foi possível contemplar o desenvolvimento de um sensor baseado em redes de Bragg em fibras óticas para implantação direta no tecido ósseo. Posteriormente foram realizados testes-piloto para o desenvolvimento da metodologia de construção e implante no desenvolvimento de biosensores. Com todo o trabalho feito até à data, o desenvolvimento e construção de um biosensor que foi implantado in vivo foi possível. O biossensor foi fixado na região mandibular de um bovino quatro meses de idade. Uma semana após a implantação, os animais receberam diferentes tipos de alimentos e foi monitorizada durante a ingestão de alimentos. Com as deformações medidas foi possível a análise dos diferentes padrões mastigatórios e diferentes magnitudes de força e frequência mastigatória que o animal desempenhada durante o processo de mastigação. / This study aims to develop a biosensor using Bragg gratings in optical fibers, capable of measuring deformation in bone tissue for this took a lot of work. Initially sterilization and disinfection with sensors tests were performed after the entire process, the sensors were tested for their sensitivity. In the same study methods of sterilization and disinfection have been tested to assess its efficiency. Thus methods of sterilization and disinfection autoclave, ethylene oxide, sodium hypochlorite, chloramine T and peracetic acid were effective for removing or inactivating microorganisms and, without changes in the behavior of the FBGs. With this set up methods applicable for possible studies, where optical fibers are implanted in in vivo animal studies metabolic behavior in the presence of inorganic materials. Continuing the work was carried out optical fiber compatibility tests inserted in the subcutaneous tissue of rats. Based on the descriptive analysis of histological sections can be concluded that the optical fiber uncoated and coated were biocompatible when implanted in rat subcutaneous tissue. Thus it is possible to contemplate the development of a sensor based on Bragg gratings in optical fibers for direct implantation into the bone tissue. Following on from the work were carried out pilot tests for development of construction methodology and implant in biosensor development. With all the work done to date, the development and construction of a biosensor that was implanted in vivo was possible. The biosensor was fixed in the mandibular region of a bull four months old. A week after implantation, the animal received different types of food and was monitored during the intake of foods. With the deformations measured parse the different masticatory patterns and different magnitudes of force and masticatory frequency that the animal developed during the chewing process completing the objectives of this study.
307

Avaliação do plasma rico em plaquetas no tratamento de defeitos ósseos e lesões periodontais de furca grau II. Estudos histológico e histomorfométrico em cães

Marcaccini, Andréa Márcia [UNESP] 31 August 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-08-31Bitstream added on 2014-06-13T19:44:16Z : No. of bitstreams: 1 marcaccini_am_dr_arafo.pdf: 3610599 bytes, checksum: 65fbbd0cb1b0657f1b361bf4e461a54e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos deste estudo foram avaliar o efeito de biomateriais associados ao PRP na formação óssea em defeitos padronizados de rádio e avaliar o efeito de PRP+RTG+enxerto ósseo autógeno para tratamento de lesões de furca grau II em cães. Para tal, em um primeiro estudo, foram confeccionados 5 defeitos de 5mm em cada rádio (direito e esquerdo) em 05 cães, constituindo assim espaços para preenchimento com os enxertos ou substitutos ósseos avaliados, totalizando 50 cavidades. Os materiais testados foram DFDBA, vidro bioativo, osso autógeno e osso mineral bovino, associados ou não ao PRP. Estes grupos foram avaliados e comparados com os grupos representados por coágulo sangüíneo e PRP. Ao final de 60 dias, foi realizada biópsia e preparo laboratorial para avaliação histológica e histomorfométrica. Os grupos que apresentaram melhores resultados foram coágulo, PRP e osso autógeno associado ou não a PRP; e a utilização do PRP não promoveu maior formação óssea em relação aos demais grupos, com exceção do vidro bioativo+PRP que apresentou os melhores resultados. No segundo estudo, foram criados cirurgicamente defeitos periodontais de furca nos quartos pré-molares mandibulares, bilateralmente em 5 cães, cronificados por um período de três meses e tratados por PRP/RTG/enxerto ósseo autógeno (grupo experimental) ou RTG/enxerto ósseo autógeno (grupo controle). Quatro meses após o tratamento, os cães foram sacrificados. Na área de furca, houve maior preenchimento ósseo e extensão linear de novo cemento, nova adaptação conjuntiva e regeneração periodontal no grupo experimental (p<0.005) e maior extensão linear de epitélio no grupo controle (p<0.005). A associação do PRP a RTG e enxerto ósseo autógeno proporcionou maior regeneração dos tecidos periodontais. Portanto, o PRP promoveu melhores resultados na formação óssea somente... . / The aims of this study were to evaluate the effect of biomaterials in association to PRP on bone formation, in padronized defects of radius, and evaluate the effect of PRP/GTR/autogenous bone graft in the treatment of Class II furcation lesions in dogs. For that, in a first study, five defects of 5mm each were produced in each radius (left and right) in 5 dogs, so creating spaces to be filled with grafts or the bone substitutes under study, totalling 50 cavities. The biomaterials tested were DFDBA, bioglass, autogenous bone and bovine mineral bone grafts, associated, or not, with PRP. These biomaterials were compared with coagulum and PRP. At the end of 60 days biopsy was done and histological laminas were prepared. Under the experimental condictions, coagulum, PRP and autogenous bone associated or not to PRP presented the best results, with more new bone formation; and no difference was observed between the groups with biomaterials, associated or not with PRP, excepting bioactive glass/PRP which showded the best results. In the second study, periodontal furcation defects were surgically produced bilaterally in the fourth mandibular premolars in 5 dogs, cronified for 3 months and treated with PRP/GTR/autogenous bone graft (experimental group) or GTR/autogenous bone graft (control group). Four months after the treatment, the dogs were sacrified. In the furcation area, more bone filling and linear extension of new cement, new conjunctive adaptation and periodontal regeneration were observed to occur in the experimental group (p<0.005) and more linear extension of epitelium in the control group (p<0.005). The association PRP/GTR/autogenous bone graft was observed to produce more regeneration of periodontal tissues. Therefore, the PRP association showed the best results in bone formation only at bioactive glass group; and... (Complete abstract, click electronic address below).
308

Desenvolvimento de uma matriz maleável, reabsorvível e porosa e sua aplicação no tratamento da doença periodontal pela técnica de regeneração tecidual guiada / Development of a matrix malleable, bioabsorbable, porous and its application in the treatment of periodontal disease by the technique of guided tissue regeneration

Martins, Livia Marina Alvarenga 31 July 2014 (has links)
Made available in DSpace on 2015-03-26T13:47:24Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2414435 bytes, checksum: e0ee8e2ec29d15623795df16ecdca852 (MD5) Previous issue date: 2014-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Periodontal disease is a major problem both in human and in veterinary medicine, because presents as a serious consequence of the loss of alveolar bone, besides the supporting tissues of the dental piece: cementum and periodontal ligament. The treatment of this disease is the manual removal of plaque associated with the use of different antimicrobials to prevent systemic consequences that disease can cause. However, the conventional treatment prevents the formation of periodontal tissue support, occurring only proliferation of cells of the junctional epithelium and gingival connective tissue fibroblasts. Bone defects resulting from the need to fill condition replacements for bone regeneration to occur at the appropriate location. The use of biocompatible and osteoconductive biomaterials, preferably resorbable, serves as support for bone formation and are gradually reabsorbed by the body without any adverse reaction. The aim of this study was to characterize two membranes composed of synthetic hydroxyapatite (HAP 91 PLUS ®) and polycaprolactone (PCL) in different concentrations (75HAP/25PCL and 60HAP/40PCL) and it evaluation of the use in bone defects in the alveolar bone of the jaw dogs. The analysis of the membrane by scanning electron microscopy revealed complex surface in the membrane 75HAP/25PCL and less complex in the membrane 60HAP/40PCL. Both showed high crystallinity, evaluated by x-ray diffraction, and the presence of hydroxyapatite crystals adhered to the membrane, which improve their complex topography. The average pore diameters were 15.7 (± 8.1)&#956;m and 10.4 (± 6.3) &#956;m without, however, show the presence of macropores or interconnection between the existing pores. The experimental groups were divided into control and treated, containing six animals each. Clinical evaluations and radiographs were performed two weeks after the implantation of the membrane and 60 days after operation. Histology and microtomography scan was performed at 60 days postoperatively. Were not clinically observed pain and purulent discharge, and the clinical insertion level showed no statistical difference between the groups. In treated animals, 50% of the animals showed dehiscence and 83% had membrane exposure. Radiographic images show alveolar bone radiopacity equal in both groups. The computed microtomography revealed that the control group showed, with statistical difference, the greater ratio of bone volume over the total volume of the defect in relation to the treated group, however in all animals, the furcation area was not filled by new alveolar bone. Histology revealed the presence of extensive inflammatory infiltration and connective tissue in both groups. New bone was only observed in the apical border of the defect in both the control and the treated group. / A doença periodontal é um importante problema tanto na medicina humana quanto na veterinária, pois apresenta como grave consequência a perda dos tecidos de sustentação da peça dental, sendo que o tratamento convencional retirada mecânica da placa - não permite a formação dos tecidos periodontais de sustentação. Os defeitos ósseos resultantes da afecção necessitam de preenchimento com substitutos para que ocorra a regeneração óssea apropriada no local. A utilização de biomateriais biocompatíveis e osteocondutores, preferencialmente reabsorvíveis, serve como suporte para formação óssea e são reabsorvidos gradativamente pelo organismo, sem qualquer reação adversa. O objetivo desse trabalho foi caracterizar duas membranas compostas por hidroxiapatita sintética (HAP 91 PLUS ®) e policaprolactona (PCL) em diferentes concentrações (75HAP/25PCL e 60HAP/40PCL) e avaliação da utilização da segunda em defeitos periodontais na mandíbula de cães. A análise da membrana pela microscopia eletrônica de varredura revelou superfície complexa na membrana 75HAP/25PCL e menos complexa na membrana 60HAP/40PCL. Ambas apresentaram alta cristalinidade, avaliadas pela difração de raios-X e a presença de cristais de hidroxiapatita na superfície da membrana nos quais auxiliam a complexidade da topografia. Os diâmetros médios dos poros foram de 15,7(±8,1) &#956;m e 10,4 (±6,3) &#956;m sem, entretanto, evidenciar a presença de macroporos nem a interconexão entre os poros existentes. Para explicação in vivo, os grupos experimentais foram divididos em controle e tratado, contendo seis animais cada. A doença periodontal foi induzida em três estágios em todos os animais, e seis deles receberam tratamento com a técnica de regeneração tecidual guiada. As avaliações clínicas foram realizadas durante duas semanas após a implantação da membrana e após 60 dias do pós-operatório. Radiografias foram retiradas no pré operatório imediato e aos 60 dias após tratamento. A histologia e a tomografia microcomputadorizada foram realizadas aos 60 dias do pós-operatório. Clinicamente não foram observados dor e secreção purulenta, e não houve diferença estatística no nível clinico de inserção entre os grupos avaliados. Nos animais tratados, 50% apresentaram deiscência e 83% exposição de membrana. As imagens radiográficas demonstraram radiopacidade igual ao osso alveolar na região do defeito em ambos os grupos. A tomografia microcomputadorizada revelou que o grupo controle apresentou, com diferença estatística, maior relação de volume ósseo sobre o volume total do defeito em relação ao grupo tratado, no entanto em todos os animais, a região de furca não foi preenchida por novo osso alveolar. A histologia revelou presença de grande infiltrado inflamatório e presença de tecido conjuntivo em ambos os grupos. Osso novo apenas foi observado na borda apical do defeito tanto no grupo controle quanto no grupo tratado. Assim, o biomaterial utilizado não obteve sucesso quando utilizado em defeitos periodontais, sendo necessários assim, maiores estudos quanto a sua utilização em outras regiões do organismo.
309

Avaliação do plasma rico em plaquetas no tratamento de defeitos ósseos e lesões periodontais de furca grau II. Estudos histológico e histomorfométrico em cães /

Marcaccini, Andréa Márcia. January 2004 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Joni Augusto Cirelli / Banca: Enilson Antonio Sallum / Banca: Luis Carlos Spolidorio / Banca: Paulo Tambasco de Oliveira / Resumo: Os objetivos deste estudo foram avaliar o efeito de biomateriais associados ao PRP na formação óssea em defeitos padronizados de rádio e avaliar o efeito de PRP+RTG+enxerto ósseo autógeno para tratamento de lesões de furca grau II em cães. Para tal, em um primeiro estudo, foram confeccionados 5 defeitos de 5mm em cada rádio (direito e esquerdo) em 05 cães, constituindo assim espaços para preenchimento com os enxertos ou substitutos ósseos avaliados, totalizando 50 cavidades. Os materiais testados foram DFDBA, vidro bioativo, osso autógeno e osso mineral bovino, associados ou não ao PRP. Estes grupos foram avaliados e comparados com os grupos representados por coágulo sangüíneo e PRP. Ao final de 60 dias, foi realizada biópsia e preparo laboratorial para avaliação histológica e histomorfométrica. Os grupos que apresentaram melhores resultados foram coágulo, PRP e osso autógeno associado ou não a PRP; e a utilização do PRP não promoveu maior formação óssea em relação aos demais grupos, com exceção do vidro bioativo+PRP que apresentou os melhores resultados. No segundo estudo, foram criados cirurgicamente defeitos periodontais de furca nos quartos pré-molares mandibulares, bilateralmente em 5 cães, cronificados por um período de três meses e tratados por PRP/RTG/enxerto ósseo autógeno (grupo experimental) ou RTG/enxerto ósseo autógeno (grupo controle). Quatro meses após o tratamento, os cães foram sacrificados. Na área de furca, houve maior preenchimento ósseo e extensão linear de novo cemento, nova adaptação conjuntiva e regeneração periodontal no grupo experimental (p<0.005) e maior extensão linear de epitélio no grupo controle (p<0.005). A associação do PRP a RTG e enxerto ósseo autógeno proporcionou maior regeneração dos tecidos periodontais. Portanto, o PRP promoveu melhores resultados na formação óssea somente... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aims of this study were to evaluate the effect of biomaterials in association to PRP on bone formation, in padronized defects of radius, and evaluate the effect of PRP/GTR/autogenous bone graft in the treatment of Class II furcation lesions in dogs. For that, in a first study, five defects of 5mm each were produced in each radius (left and right) in 5 dogs, so creating spaces to be filled with grafts or the bone substitutes under study, totalling 50 cavities. The biomaterials tested were DFDBA, bioglass, autogenous bone and bovine mineral bone grafts, associated, or not, with PRP. These biomaterials were compared with coagulum and PRP. At the end of 60 days biopsy was done and histological laminas were prepared. Under the experimental condictions, coagulum, PRP and autogenous bone associated or not to PRP presented the best results, with more new bone formation; and no difference was observed between the groups with biomaterials, associated or not with PRP, excepting bioactive glass/PRP which showded the best results. In the second study, periodontal furcation defects were surgically produced bilaterally in the fourth mandibular premolars in 5 dogs, cronified for 3 months and treated with PRP/GTR/autogenous bone graft (experimental group) or GTR/autogenous bone graft (control group). Four months after the treatment, the dogs were sacrified. In the furcation area, more bone filling and linear extension of new cement, new conjunctive adaptation and periodontal regeneration were observed to occur in the experimental group (p<0.005) and more linear extension of epitelium in the control group (p<0.005). The association PRP/GTR/autogenous bone graft was observed to produce more regeneration of periodontal tissues. Therefore, the PRP association showed the best results in bone formation only at bioactive glass group; and... (Complete abstract, click electronic address below). / Doutor
310

Sistema de informação para gerenciamento de equipamentos médicos-hospitalares / Information system for management of medical-hospital equipment

Piccinini, Patricia Strapasson 31 August 2016 (has links)
Os equipamentos médicos, sob regime da Vigilância Sanitária, compreendem todos os equipamentos de uso em saúde com finalidade médica, odontológica, laboratorial ou fisioterápica, utilizados direta ou indiretamente para diagnóstico, terapia, reabilitação ou monitorização de seres humanos. A manutenção desses equipamentos é atribuída a área de engenharia clínica. A engenharia clínica atua no desenvolvimento, gerenciamento, manutenção, incorporação e capacitação dos equipamentos médicos-hospitalares (EMH) dentro do hospital, visando contribuir com a qualidade de vida dos pacientes. Para melhorar a gestão destes equipamentos, aliou-se a informática, por meio dos sistemas de informação à área de manutenção. Os softwares destinados à área hospitalar existentes, são na maioria comerciais, caros e estão voltados à gestão dos pacientes, gestão de leitos e prontuários. A existência dos sistemas de informatização com a finalidade de auxiliar na manutenção, pode reduzir o tempo e o custo destinado a esta atividade. O objetivo deste estudo é analisar e implementar um sistema de informação para gerenciamento de manutenção de EMH. Este sistema é 100% Web, multiplataforma, que usa um método de priorização para manutenções preventiva e corretivas. Foram criados formulários personalizados para cada EMH visando a padronização de como serão armazenadas as soluções de cada manutenção. Para o desenvolvimento do sistema, foi aplicada a Análise Orientada a Objetos, por meio de técnicas da engenharia de software. O código do sistema foi desenvolvido usando a linguagem de programação PHP, utilizando um framework frontend Bootstrap e um banco de dados PostgreSQL. Com o sistema pronto foram criados métodos de testes de software disponibilizando roteiros para testar a usabilidade do software. Comparando o SIGEMH e outros softwares disponíveis no mercado, foi constatado que a maioria contempla os aspectos gerenciais de EMH, enquanto que o SIGEMH tem como meta a priorização e a padronização de formulários referentes às manutenções. Algumas funcionalidades existentes no outros softwares não foram desenvolvidas, mas implementou-se novas funcionalidades, tais como: o armazenamento de normas técnicas e manuais para pesquisas on-line, a padronização dos formulários pós manutenção e o método de priorização que define as ordens dos equipamentos para a realização dos serviços. / The medical equipment, under sanitary vigilance rules, comprehend all equipment in use in the health field with medical, odontological, laboratorial or physiotherapeutic purpose, which are used either directly or indirectly for diagnosis, therapy, rehabilitation, or monitoring of human beings. The maintenance of these equipment is attributed to the clinical engineering area. The clinical engineering acts on development, management, maintenance and capacitation of medical-hospital equipment (MHE), within the hospital, aiming to contribute to the patients? quality of life. In order to improve the management of these equipment, it has allied with informatics, by means of information systems in the maintenance field. Most of the existing softwares for the hospital area are commercial, expensive and are meant to patients, beds and medical records managing. The existence of informatization systems with the aim of helping maintenance may cut down the time and the cost for this activity. The purpose of this study is to analyze and to implement an information system for managing the maintenance of MHE. This system is 100% Web, multiplatform, and uses a prioritizing method for preventive and corrective maintenance. Customized forms were created for each MHE, aiming the standardization of storage of solutions for each maintenance. For the developing of the system, the Object Oriented Analysis was applied, with techniques of software engineering. The system code was developed using PHP programming language, using a Bootstrap frontend framework and a PostgreSQL database. When the system was ready, software testing methods were created, providing itineraries to test the software?s usability. Comparing to SIGEMH and other softwares on the market, it was found that the majority regards the managing aspects of MHE, while SIGEMH aims the prioritization and standardization of forms relative to maintenance. Some functionalities present in other softwares were not developed, but new functionalities were implemented, such as: storage of technical rules and manuals for online searching, standardization of post-maintenance forms and the method which defines the order of equipment for service execution.

Page generated in 0.1164 seconds