• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 296
  • 93
  • 8
  • 8
  • 7
  • 7
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 464
  • 110
  • 107
  • 85
  • 73
  • 68
  • 64
  • 57
  • 52
  • 50
  • 50
  • 49
  • 47
  • 44
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Perfil microbiológico da colonização do sítio de inserção do cateter venoso central / Microbiological profile of the colonization of the insertion site on central venous catheter

Pereira, Gabriela Levorato 25 September 2015 (has links)
O uso do Cateter Venoso Central (CVC) viabiliza a assistência de alta complexidade aos pacientes críticos. Contudo, as infecções desses cateteres demonstram uma associação com a migração dos microrganismos da pele do local de inserção até a ponta do cateter. A utilização de novas tecnologias para reduzir a colonização cutânea no sítio de inserção do cateter reforça a questão da antissepsia cutânea e a sugestão do curativo adequado a esta região. As recomendações do Centers for Disease Control and Prevention (CDC) apontam como uma opção de curativo o uso da cobertura de filme transparente de poliuretano (FTP) que protege e facilita a visualização do sítio de inserção. Contudo, o uso do curativo gel de clorexidina (CGCHX), vem apresentado uma resposta superior na prevenção dessas colonizações e infecções. Diante do exposto, propôs-se identificar por meio de um estudo de corte transversal prospectivo, os microrganismos presentes no swab de pele após o uso do CGCHX e do FTP, no momento da retirada do CVC. Fizeram parte do estudo um total de 92 pacientes, destes 45 pacientes em uso do CGCHX e 47 utilizaram FTP, em ambos os grupos, a faixa etária foi em média 60 anos, declararam-se brancos e não houve diferença significativa entre o número de homens e mulheres. A escolha do sítio de inserção preferencial foi a veia jugular interna direita. Houve o crescimento em 13 amostras de Swabs no grupo do CGCHX os microrganismos encontrados foram Acinetobacter baumannii, Pseudomonas aeruginosa, Morganella morganii, Enterobater cloacae, Staphylococcus aereus e Staphylococcus epidermidis. O Staphylococcus aereus apresentou resistência a oxacilina, o que podemos sugerir a possibilidade de uma cepa MRSA. Quanto ao FTP foram seis amostras positivas com o crescimento de Serratia marcescens, Acinetobacter baumannii, Klebsiella pneumoniae, Staphylococcus epidermidis e Staphylococcus haemolyticus. A presença da Klebsiella pneumoniae sensível somente a amicacina sugere a possibilidade da cepa Klebsiella pneumoniae carbapenemas (KPC). Apesar dos achados evidenciarem um número maior de crescimento bacteriano no curativo gel de CHX, este estudo pode contribuir para o olhar e desenvolvimento de novos trabalhos para a nossa população, levando em consideração nosso clima e tipo de pele, como também a importância de medidas educativas permanentes no treinamento da equipe de saúde nos centros onde as novas tecnologias são implementadas / The use of Central Venous Catheter (CVC) enables the high complexity assistance to critically ill patients. However, these catheters infections show an association with the migration of skin microorganisms from the insertion site to the tip of the catheter. The use of new technologies to reduce skin colonization on the catheter insertion site reinforces the issue of skin disinfection and use of suitable dressing to this region. The recommendations from the Centers for Disease Control and Prevention (CDC) show the use of coverages with transparent polyurethane film (TPF) as an option of dressing, which protects and facilitates the visualization of the insertion site. However, the use of chlorhexidine gel dressing (CGD) has presented a higher response in preventing these colonizations and infections. Given the above, this study aimed to identify the microorganisms present on the skin swab after using the CGD and TPF at the time of removal of the CVC from a prospective cross-sectional study. The total of participants were 92 patients, 45 of them were using CGD and 47 were using FTP. In both groups, the average age was 60 years, white, and there was no significant difference between the number of men and women. The choice of preferred insertion site was the right internal jugular vein. There was growth in 13 samples Swabs in the CGD group. Microorganisms found were Acinetobacter baumannii, Pseudomonas aeruginosa, Morganella morganii, Enterobater cloacae, Staphylococcus aereus and Staphylococcus epidermidis. Staphylococcus aereus showed resistance to oxacillin, which can suggest the possibility of a MRSA strain. Related to the FTP group, there were six positive samples with the growth of Serratia marcescens, Acinetobacter baumannii, Klebsiella pneumoniae, Staphylococcus epidermidis and Staphylococcus haemolyticus. The presence of Klebsiella pneumoniae sensitive only to amikacin suggests the possibility of Klebsiellapneumoniaecarbapenemase strain (KPC). Despite findings showing a greater number of bacterial growth in the chlorhexidine gel dressing, this study may contribute to the development of new studies for population, taking into account the climate and skin type, as well as the importance of educational measures for the training of health team in centers where new technologies are implemented
232

AVALIAÇÃO DA QUALIDADE DA ÁGUA MINERAL COMERCIALIZADA EM POSTOS DE COMBUSTÍVEIS NO MUNICÍPIO DE GOIÂNIA.

Carvalho, Murilo Ferreira de 26 February 2015 (has links)
Made available in DSpace on 2016-08-10T10:44:44Z (GMT). No. of bitstreams: 1 MURILO FERREIRA DE CARVALHO.pdf: 1400419 bytes, checksum: 75547043b3858db174b07a0ac8565597 (MD5) Previous issue date: 2015-02-26 / Water is a vital resource to life. The use of a water that does not offer risks to the health of the consumer is guaranteed by the law, however, there is a need to ensure, through the verification of some parameters, that the water is of good quality, and thus, the mineral water can appear as a safe option, and this fact is verified by continuous growth in demand for this type of product. The objective of this work was to analyze some of the parameters of quality of natural mineral water, bottled in gallons 20 liters which is marketed in fuel stations in the city of Goiania and compare them with the relevant legislation. Among the physical-chemical parameters were evaluated pH, conductivity, total dissolved solids, levels of nitrate and fluoride. And among the microbiological parameters were evaluated the total coliform and thermotolerant coliform. We collected 21 samples, in seven points of sale different, in the months of June, August and October 2014, for that would have a differentiation in the lots of the products. For the evaluation of the pH was used the potentiometric method, for the conductivity, the method of conductivity, for total dissolved solids the gravimetric method, for the levels of nitrate the spectrophotometric method and for the fluoride the selective ion electrode method. Total coliforms and thermotolerant coliforms were determinated by the technique of multiple tubes. All samples, except only one (4.76 %), were within the parameters required by law relative to microbiological analyses, certifying that the mineral water is of good quality. The sample that was not within the parameters, presented total coliforms, but the contamination by this type of bacterium, can be an indication that the hygienic and sanitary conditions during the production process were far below what is needed. In addition, with respect to the physical-chemical parameters, although the samples were within the standards of the law, the labels of the products showed a significant difference when compared with the results obtained. Therefore, it is important to have a continuous monitoring of sources of mineral water and also the monitoring of the parameters that attest to the quality of the products that reach consumers. / A água é um recurso indispensável à vida. O uso de uma água que não ofereça riscos à saúde do consumidor é garantido pela legislação, no entanto, é preciso assegurar, mediante a verificação de alguns parâmetros, que a água é de boa qualidade e, sendo assim, a água mineral pode aparecer como uma opção segura, e esse fato é verificado pelo crescimento contínuo na demanda por esse tipo de produto. O objetivo desse trabalho foi analisar alguns parâmetros de qualidade da água mineral natural, envasada em galões de 20 litros que é comercializada em postos de combustível no município de Goiânia e compara-los com a legislação pertinente. Dentre os parâmetros físico-químicos, foram avaliados o pH, a condutividade, os sólidos dissolvidos totais, os teores de nitrato e fluoreto. E dentre os parâmetros microbiológicos, foram analisados os coliformes totais e os coliformes termotolerantes. Foram coletadas 21 amostras, em sete pontos de venda diferentes nos meses de junho, agosto e outubro de 2014, para que houvesse uma diferenciação nos lotes dos produtos. Para a avaliação do pH, foi empregado o método potenciométrico, para a condutividade, o método do condutivímetro, para os sólidos dissolvidos totais o método gravimétrico, para os teores de nitrato o método espectrofotométrico e para o fluoreto o método de eletrodo íon seletivo. A determinação dos coliformes totais e coliformes termotolerantes foi feita pela técnica dos tubos múltiplos. Todas as amostras, com exceção de uma (4,76%), se mostraram dentro dos parâmetros exigidos por lei no que se refere às análises microbiológicas, atestando que a água mineral é de boa qualidade. A amostra que não estava dentro dos parâmetros, apresentou coliformes totais, porém, a contaminação por esse tipo de bactéria pode ser indicativo de que as condições higiênico-sanitárias durante o processo produtivo estavam aquém do necessário. Além disso, com relação aos parâmetros físico-químicos, embora as amostras estivessem dentro dos padrões da legislação, os rótulos dos produtos mostraram significativa diferença quando comparados com os resultados obtidos. Por essa razão, é importante a contínua fiscalização das fontes de água mineral e também o monitoramento desses parâmetros que atestam a qualidade dos produtos que chegam aos consumidores.
233

Detecção e contagem de Streptococcus agalactiae em leite bovino pela reação em cadeia da polimerase / Detection and counting of Streptococcus agalactiae in bovine milk by polymerase chain reaction

Carvalho, Nara Ladeira de 31 July 2013 (has links)
O objetivo do presente estudo foi: a) comparar dois métodos de detecção e contagem de S. agalactiae, (cultura microbiológica e qPCR) em leite de vacas e de tanques; b) determinar a sensibilidade analítica e a repetibilidade do diagnóstico por qPCR em relação à cultura microbiológica para detecção de S. agalactiae em amostras compostas de leite de vaca e de tanque. Foram utilizadas amostras de leite de vaca (n=31) e de tanque (n=150), as quais foram submetidas à cultura microbiológica e contagem de S. agalactiae por cultura de microbiologia convencional e qPCR. Para avaliar a sensibilidade analítica, foi construída uma curva padrão com amostras de leite desnatado reconstituído estéril contaminado artificialmente com S. agalactiae (ATCC 13813). Em apenas duas amostras não foi possível amplificação de DNA, o que indica que a qPCR foi capaz de detectar S. agalactiae, em 96% e 97%, do leite de vaca e de tanque, respectivamente. Embora a técnica qPCR tenha apresentado alta sensibilidade analítica, não houve equivalência de resultados de contagem S. agalactiae entre os dois métodos propostos. Os coeficientes de variação interensaio utilizados para avaliar a técnica qPCR foram < 5%, o que demonstra que a técnica possui repetibilidade adequada. Portanto, não houve equivalência entre a contagem de S. agalactiae por cultura microbiológica padrão e a técnica de qPCR, provavelmente pela alta sensibilidade da técnica qPCR em quantificar DNA de células inviáveis. No entanto, a qPCR apresentou-se como uma técnica sensível para identificação de S. agalactiae em amostras de leite de vaca e de taque. / The aim of this study was to: a) to compare two methods of detection and enumeration of S. agalactiae (microbiological culture and qPCR) in cow`s milk and bulk tank milks, b) to determine the analytical sensitivity and repeatability of the diagnosis by qPCR in relation to microbiological culture for detection of S. agalactiae on composite samples of cow\'s milk and bulk tank milk. Samples of cow\'s milk (n = 31) and bulk tank milk (n = 150), which were submitted to microbiological culture and enumeration of S. agalactiae by conventional microbiology culture and qPCR. To evaluate the analytical sensitivity, a standard curve was made with samples of sterile reconstituted skim milk artificially contaminated with S. agalactiae (ATCC - 13813). In two samples was not possible the amplification of DNA, indicating that qPCR was able to detect S. agalactiae, 96% and 97% cow\'s milk and bulk tank milk, respectively. Although the technique has presented qPCR high analytical sensitivity, there was no equivalent result of counting S. agalactiae between the two proposed methods. The interassay coefficients of variation technique used to evaluate the qPCR were <5%, which demonstrate that the technique has adequate repeatability. So there was no equivalence between the counts of S. agalactiae by standard microbiological culture and qPCR technique, probably due to the high sensitivity of qPCR technique to quantify DNA of unviable cells. However, the qPCR presented as a sensitive technique for identifying S. agalactiae in samples of cow\'s milk and bulk tank milk.
234

Impacto do processo térmico assistido por micro-ondas sobre a funcionalidade do leite humano. / Impact of the microwave-assisted heating on the functionality of human milk.

Leite, Juliana Aparecida dos Santos 06 March 2018 (has links)
Neste trabalho, foram determinadas as propriedades dielétricas e a condutividade elétrica de quatro tipos leite (leite humano e 3 tipos de leite vaca - cru, integral e semi-desnatado) e de três fórmulas infantis (FIs) empregando a técnica de cabo coaxial de ponta aberta. As medições das propriedades dielétricas foram realizadas na faixa de frequência de (500 a 3000) MHz e em temperaturas de (5 a 90) ºC. O comportamento dielétrico de todos os tipos de leite e das FIs foi caracterizado por dois mecanismos principais (condução iônica e rotação dipolar), que se mostraram dependentes da frequência e da temperatura. Também foi estudada a inativação da enzima fosfatase alcalina (ALP), presente em leite de vaca e humano, utilizando um reator de micro-ondas focalizadas em processo térmico descontínuo. Durante o processamento, por meio de um sensor de fibra óptica, em contato direto com o leite, foram obtidos os históricos de temperatura dos quais os parâmetros cinéticos D e z foram calculados no intervalo de temperatura de (50 a 80) ºC e tempos de (15, 30, 45, 60, 180 e 300) s. A inativação térmica da ALP obedeceu a cinética de primeira ordem e os parâmetros cinéticos determinados foram: z = 4,4 ºC e D70ºC = 1,1 s para o leite humano e z = 7,4 ºC e D70ºC = 44,3 s para o leite de vaca tipo B. Os resultados desse estudo mostraram que o tratamento térmico assistido por micro-ondas, na condição ótima de 60 ºC por 30 s, foi eficiente na inativação de micro-organismos patogênicos (Staphylococcus aureus e Salmonella) e na preservação do perfil de ácidos graxos em leite humano. Além disso, o tratamento térmico assistido por microondas resultou em menores perdas de proteínas, como as imunoglobulinas e lactoferrina, quando comparado ao processamento térmico convencional (Holder), utilizado nos Bancos de Leite Humano (BLH), demonstrando que pode ser considerado uma tecnologia alternativa para o processamento de alimentos líquidos. / In this work, the dielectric properties and electrical conductivity of four types of milk (human milk and 3 types of cow milk - raw, whole and low-fat) and three infant formulae (IFs) were measured using the open-ended coaxial method. The measurements of the dielectric properties were performed at frequency range from (500 to 3000) MHz and temperatures from (5 to 90) ºC. The dielectric behavior of all types of milk and IFs was characterized by two main mechanisms (ion conduction and dipole rotation), which showed dependency in relation to frequency and temperature. The inactivation of alkaline phosphatase (ALP), present in cow and human milk, was also studied using a microwave reactor focused on a batch process. During the processing, by means of a fiber optic sensor, the temperature histories were obtained from which the kinetic parameters D and z were calculated at temperature range from (50 to 80) °C and times from (15, 30, 45, 60, 180 and 300) s. The thermal inactivation of the ALP followed the first-order kinetics and the kinetic parameters determined were: z = 4.4 °C and D70°C = 1.1 s for human milk and z = 7.4 °C and D70 °C = 44.3 s for the type B cow\'s milk. The results of this study showed that microwave-assisted heating, under optimum condition (60 ºC for 30 s), was efficient for inactivation pathogenic microorganisms (Staphylococcus aureus and Salmonella) and preservation of fatty acids profile in human milk. In addition, microwave-assisted heating resulted in lower losses of important proteins, such as immunoglobulins and lactoferrin, compared to conventional thermal processing (Holder), used in Human Milk Banks (BLH), demonstrating that it can be considered an alternative technology for the processing of liquid foods.
235

Ocorrência e caracterização de Giardia e Cryptosporidium em águas captadas para abastecimento público no município de Cajamar-SP e avaliação do risco / Occurrence and characterization of Giardia and Cryptosporidium in water collected for public supply in the municipality of Cajamar-SP and risk assessment

Bataiero, Marcel Oliveira 18 April 2016 (has links)
Introdução: O risco à saúde humana ocasionado pela contaminação biológica de águas captadas para abastecimento público é realçado pela ocorrência de surtos de doenças associadas aos protozoários Giardia e Cryptosporidium, que possuem baixas doses infecciosas e alta capacidade de sobrevivência no ambiente, além de serem capazes de resistir ao processo tradicional de desinfecção da água (cloração). Partindo-se da hipótese de que há um risco elevado de infecção por estes protozoários pela ingestão de água tratada por métodos convencionais e que fazem uso de mananciais superficiais impactados por contaminação biológica, resultando num possível incremento da incidência de diarréias, este estudo se propôs a verificar a ocorrência destes protozoários em águas captadas para abastecimento público no município de Cajamar-SP, caracterizar sua patogenicidade e avaliar o risco associado ao seu consumo através da água tratada. Métodos: Foram coletadas 48 amostras do ribeirão dos Cristais no ponto de captação da estação de tratamento de água, semanalmente, durante 12 meses (de 16/05/2013 a 21/05/2014). A detecção e a análise da concentração dos protozoários foram realizadas de acordo com Método 1623.1 da United States Environmental Protection Agency e a extração e caracterização dos espécies/genótipos de Giardia e Cryptosporidium foi realizada através metodologias moleculares e seqüenciamento. O risco de infecção pela ingestão de cistos de Giardia e oocistos de Cryptosporidium presentes na água tratada foi calculado usando a ferramenta da Avaliação Quantitativa do Risco Microbiológico, a partir dos dados de concentração dos patógenos obtidos pelo Método 1623.1, eficiência de remoção dos (oo)cistos durante o processo convencional de tratamento da água, modelo dose-resposta e taxa de ingestão diária de água para indivíduos menores de 5 anos e maiores de 21 anos. Resultados: Cistos de Giardia foram detectados em 83,3% das amostras (40/48), com concentrações variando desde o limite de detecção (&lt;0,1) até 8,6 cistos/L. Oocistos de Cryptosporidium foram etectados em 37,5% das amostras (18/48), com concentrações variando desde o limite de detecção (&lt;0,1) até 2 oocistos/L. As espécies/genótipos encontrados (Giardia intestinalis A e B e Cryptosporidium parvum e hominis) são característicos de contaminação antrópica e são frequentemente identificados em estudos epidemiológicos como responsáveis por surtos. A estimativa do risco anual de infecção por Giardia foi de 3,3x10-3 (IC95% 4,6x10-3) para crianças e de 11,5x10-3 (IC95% 13,3x10-3) para adultos, enquanto o risco por Cryptosporidium foi de 1,1x10-3 (IC95% 1,7x10-3) para crianças e de 3,9x10-3 (IC95% 5,0x10-3) para adultos. O incremento da incidência de diarréias foi observado no cenário de estudo após um acidente que resultou em transbordamento de esgotos não tratados no manancial, coincidindo com o aumento na detecção de (oo)cistos. Conclusão: Os resultados evidenciaram que a vulnerabilidade do ribeirão dos Cristais a contaminações biológicas pode culminar em um risco elevado de infecção e adoecimento por Giardia e Cryptosporidium através da ingestão de água tratada. Portanto, o caso é preocupante, tanto do ponto de vista do tratamento e abastecimento de água potável, quanto da degradação e contaminação do manancial, evidenciando a necessidade de se estabelecer medidas de intervenção direcionadas a promover a qualidade da água e garantir sua segurança / Introduction: The risk to human health caused by biological contamination of source water from public water supply is highlighted by the occurrence of outbreaks associated with the protozoa Giardia and Cryptosporidium, which have low infectious doses and high capacity of survival in the environment, besides being capable of withstanding traditional process for water disinfection (chlorination). Considering that there is a high risk of infection by these protozoa through drinking water treated with conventional methods uptaked from surface waters impacted by biological contamination, resulting in a possible increase in the incidence of diarrhea, this study aimed to verify the occurrence of these protozoa in waters collected for public supply in Cajamar-SP, characterize their pathogenicity and evaluate the risk associated with its consumption. Methods: Forty eight samples were collected in ribeirão dos Cristais, at uptake point of the water treatment plant, weekly, for 12 months (from 05/16/2013 to 05/21/2014). The detection and quantification of protozoa were carried out according to the United States Environmental Protection Agency Method 1623.1, and the extraction and characterization of species/genotypes of iardia and Cryptosporidium were performed through molecular methods and sequencing. The risk of infection by ingestion of Giardia and Cryptosporidium (oo)cysts present in the treated water were calculated using the Quantitative Microbial Risk Assessment tool, based on the concentration data of pathogens obtained by the Method 1623.1, removal efficiency of (oo) cysts in the conventional process of water treatment, dose-response model and rate of daily water intake for individuals under the age of 5 years and over 21 years. Results: Giardia cysts were detected in 83.3% of the samples (40/48), with concentrations ranging rom the detection limit (&lt;0.1) to 8.6 cysts/L. Cryptosporidium oocysts were detected in 7.5% of the samples (18/48), with concentrations ranging from the detection limit (&lt;0.1) to 2 oocysts/L. The species/genotypes found (Giardia intestinalis A and B and Cryptosporidium parvum and hominis) are characteristic of anthropogenic contamination and are often identified in epidemiological studies as being responsible for outbreaks. The estimated annual risk of infection by Giardia was 3,3x10-3 (95% CI 4,6x10-3) for children and 11,5x10-3 (95% CI 13,3x10-3) for adults, while the risk for Cryptosporidium was 1,1x10-3 (95% CI 1,7x10-3) for children and 3,9x10-3 (95% CI 5,0x10-3) for adults. The increase in the incidence of diarrhea was observed in the study scenario after an accident that resulted in an overflow of untreated sewage that reached the reservoir, coinciding with an increase in the detection of the (oo)cysts. Conclusion: The results showed that the vulnerability of the ribeirão dos Cristais to biological contamination may result in a high risk of infection and illness by Giardia and Cryptosporidium through the drinking water consumption. Therefore, the case is of concern, both from the point of view of the treatment and supply of drinking water, as well as to the degradation and contamination of the water source, highlighting the need to establish intervention measures aimed at promoting water quality and ensure its safety
236

Hidroxiapatita associada a gentamicina: um estudo da influencia da gelatina no meio da precipitação e do processo de secagem na inibição do crescimento bacteriano

Moreira, Jussany Maria de Barros 27 October 2009 (has links)
Made available in DSpace on 2017-07-24T19:38:01Z (GMT). No. of bitstreams: 1 dissertacao - parte liberada.pdf: 1154549 bytes, checksum: d7a9809bce797a5c245ab7132bbf659b (MD5) Previous issue date: 2009-10-27 / Several studies have demonstrated that hydroxyapatite outstands amongst bioceramics, since it presents excellent biocompatibility with human bone mineral phase, stoichiometric formula (Ca10(PO4)6(OH)2 ), with Ca/P ratio equal 1,67. It also has the capability of bonding chemically with the tissue, which makes it a bioactive material. Despite the structure and properties of bone tissue representing one of the major fields of study, nowadays the interest is in the possibility of incorporating drugs to such biomaterials. In this work, HA and HA:Gel composites were prepared through the precipitation method, which consisted of the mixture of a Ca(OH)2 (2 mol.L-1 ) solution to a H3PO4 (1,2 mol.L-1) solution, in constant agitation, heating and pH control. The precipitate obtained were put to age for a day and later one part of them was dried in oven at 100ºC and another part lyophilized for 48 hours. Powders were then sieved, calcined and had gentamicin sulfate (C21H43N5O7.2,5H2SO4) added to them in 0,25, 0,5, 1,0 e 2,0% in mass concentrations. These powders were characterized through: infrared absorption spectroscopy, X-ray diffractometry, scanning electronic microscopy (SEM), transmission electronic microscopy (TEM), granulometric analyses, specific superficial area by the BET method, differential thermal analysis (DTA) and thermogravimetry (TG). In all samples analyzed, the mineral part was characterized as carbonated hydroxyapatite. It was observed that the morphology and crystal size are influenced by the drying method and gelatin addition. The Ca/P ratio found was above the desired one for the stoichiometric hydroxyapatite. Through the SEM and TEM analysis, the presence of agglomerates, characteristic to apatites was noticed. The samples microbiological activity evaluation with saliva, with 0,5, 1,0 e 2,0% gentamicin sulfate in mass resulted in UFC equal zero, and samples with 0,25% of the same drug in mass presented sharp decrease in the colonies development, however, only the HA:Gel dried in oven, the UFC remained equal zero. Microbiological analysis results confirm the antibiotic inhibitor action when impregnating the hydroxyapatite. / Estudos demonstram que a hidroxiapatita, vem se destacando entre as biocerâmicas, pois apresenta excelente biocompatibilidade com a fase mineral do osso humano, de fórmula estequiométrica (Ca10(PO4)6(OH)2 ), com razão Ca/P igual a 1,67. Tem a capacidade de unir-se quimicamente com o tecido, o que a torna um material bioativo. Apesar da estrutura e propriedades do tecido ósseo representar um dos maiores campos de estudo, na atualidade o interesse está na possibilidade de incorporação de drogas a esses biomateriais. Neste trabalho foram preparados compósitos de HA e HA:Gel pelo método da precipitação, que consistiu na mistura de uma solução de Ca(OH)2 (2 mol.L-1) com uma solução de H3PO4 (1,2 mol.L-1), sob agitação constante,aquecimento e controle de pH. Os precipitados obtidos foram envelhecidos por um dia e posteriormente uma parte deles foi seco em estufa à 100ºC e a outra parte foi liofilizada por 48 horas. Os pós foram peneirados, calcinados e em seguida adicionados sulfato de gentamicina (C21H43N5O7.2,5H2SO4) em concentrações de 0,25, 0,5, 1,0 e 2,0% em massa. Os pós obtidos foram caracterizados por: espectroscopia de absorção na região do infravermelho; difratometria de Raios X; microscopia eletrônica de varredura (MEV-EDS), microscopia eletrônica de transmissão (MET), análises granulométricas, área superficial específica pelo método BET; análise térmica diferencial (DTA) e termogravimetria (TG). Em todas as amostras analisadas a parte mineral foi caracterizada como hidroxiapatita carbonatada. Foi verificado que a morfologia e o tamanho dos cristais são influenciados pelo tipo de secagem e pela adição de gelatina. A razão Ca/P encontrada foi superior a desejada para hidroxiapatita estequiométrica. Através das análises de MEV e MET observa-se a presença de aglomerados, característicos as apatitas. A avaliação da atividade microbiológica das amostras frente à saliva, com impregnação de 0,5, 1,0 e 2,0% em massa de sulfato de gentamicina obteve-se a contagem de Unidade Formadora de Colônia (UFC) igual a zero, sendo que nas amostras com 0,25% em massa do mesmo antibiótico houve uma grande diminuição no crescimento de colônias, porém apenas na amostra de HA:Gel seca em estufa, a contagem de UFC, permaneceu igual a zero. Os resultados das análises microbiológicas comprovam a ação inibidora do antibiótico quando impregnados a hidroxiapatita.
237

Controle de Salmonella sp. em carcaças de frango pelo uso de descontaminantes químicos durante o processo de abate e as consequências na qualidade da carne /

Nicolau, Juliana Pampana. January 2016 (has links)
Orientador: Elisa Helena Giglio Ponsano / Coorientador: Marcos Franke Pinto / Banca: Maria Luiza Poiatti / Banca:Andréa Fontes Garcia / Banca: Flavia Lombardi Lopes / Banca:Marcelo Vasconcelos Meireles / Resumo: O Brasil é um grande produtor e exportador de carne de frango e, por isso, deve primar em fornecer o produto com segurança e qualidade. A Salmonella sp. destaca-se dentre os patógenos que podem contaminar a carne de frango e, para minimizar sua prevalência, a legislação brasileira permite o uso de até 5 ppm de hipoclorito de sódio no pré-resfriamento de carcaças de frango, enquanto que outros países preconizam o uso de ozônio e ácido láctico para a mesma finalidade. Este estudo objetivou verificar se diferentes concentrações de hipoclorito de sódio, ozônio e ácido láctico, utilizados isoladamente e em conjunto na descontaminação de carcaças de frango, são eficazes na eliminação desse patógeno e se provocam alterações em suas características de qualidade. Para pesquisar a eliminação da Salmonella sp., carcaças foram contaminadas com Salmonella Enteritidis e, em seguida, submetidas aos tratamentos com os sanitizantes. Para a pesquisa sobre as características da carne, as carcaças foram tratadas com os sanitizantes e analisadas quanto a pH, rancidez, cor e sabor. O hipoclorito de sódio foi o sanitizante mais eficiente para a descontaminação das carcaças e, também, o que mais provocou alterações nas características da carne, como a redução do pH e da rancidez e o aumento da luminosidade. Na análise sensorial, não se encontrou diferença entre os tratamentos com os diferentes sanitizantes. Concluiu-se que o uso isolado do hipoclorito de sódio na concentração máxima permitida no Bra... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brazil is a major producer and exporter of poultry meat and must aim to provide the product with safety and quality. Salmonella sp. is among the pathogens that can contaminate poultry meat and, to minimize its prevalence, Brazilian laws allow the use of up to 5 ppm of sodium hypochlorite in the precooling of poultry carcasses while other countries recommend the use of ozone and lactic acid. This study aimed to investigate if sodium hypochlorite, ozone and lactic acid used in different concentrations for the decontamination of broilers carcasses, alone or in combination, are effective for eliminating this pathogen and if their use may change the quality characteristics of broiler meat. To investigate the elimination of Salmonella sp., the carcasses were contaminated with Salmonella Enteritidis and then treated with the sanitizers. For the evaluation of the meat characteristics, carcasses were treated with the sanitizers and analyzed for pH, rancidity, color and flavor. Sodium hypochlorite was the most efficient sanitizer for the decontamination of the carcasses and also the one which caused most changes in meat characteristics, such as lowering pH and rancidity and increasing lightness. Sensory analysis showed no difference among treatments. In conclusion, the use of sodium hypochlorite alone at the maximum allowable concentration in Brazil was enough to eliminate the pathogen, not requiring the use of any other sanitizers for the same purpose, and the changes it caused to mea... (Complete abstract click electronic access below) / Doutor
238

Aspectos da qualidade da tetraciclina em preparações farmacêuticas sólidas. Correlação entre os métodos de dosagem por cromatografia líquida de alta eficiência e turbimético / Aspects of the quality of tetracycline in solid pharrnaceutical forrnulations. Correlation between HPLC and microbiological methods

Yamamoto, Célia Hitomi 26 March 1999 (has links)
As tetraciclinas são encontradas no mercado sob várias formas farmacêuticas, sendo provenientes de diversos laboratórios farmacêuticos. Com o objetivo de avaliar a qualidade destes medicamentos, foram realizados os ensaios de dissolução in vitro e determinação quantitativa. Um total de 38 amostras de cápsulas de cloridrato de tetraciclina, fosfato de tetraciclina e cloridrato de oxitetraciclina e drágea de cloridrato de doxiciclina, englobando 12 fabricantes, foram analisadas. A dissolução do princípio ativo foi determinada para todas as amostras, conforme o método recomendado pela USP XXIII. Das amostras, duas foram reprovadas e outras quatro foram aprovadas após o reteste. A variação dos valores individuais obtidos no ensaio de dissolução para cada amostra, foi significativa, apresentando coeficiente de variação de até 14,2 %. A determinação quantitativa através do método microbiológico turbidimétrico empregando Staphylococcus aureus ATCC 29737, resultou em duas amostras de um mesmo fabricante com potência muito abaixo do limite especificado de 90 a 125 % do valor rotulado, com 55.5 e 68,7 %. Estudo comparativo desta metodologia com o método de cromatografia líquida de alta eficiência (CLAE) foi realizado. Para isto, o método da USP XXIII foi escolhida após o ensaio preliminar, seguido de determinação dos parâmetros de validação e adequação do método. O sistema cromatográfico estabelecido consistiu de coluna de fase reversa SYMMETRYTM C8 e fase móvel composta de oxalato de amônio 0,09 M, dimetilformamida e fosfato dibásico de amônio 0.18 M (64:32:4.7) com pH entre 7,6 e 7.7. Os resultados para determinação de cloridrato de tetraciclina confirmaram os valores obtidos no ensaio microbiológico, sendo reprovadas duas amostras. O teor máximo encontrado de 4-epianidrotetraciclina foi de 0,5 %, abaixo do limite de 3 % especificado na USP XXIII. Na comparação entre os dois métodos, foram observados resultados sempre superiores para o método microbiológico. A análise estatística destes resultados mostrou diferença significativa entre as médias das determinações obtidas a partir de cada método. / Tetracyclines are avaiable under several pharmaceutical forms and manufactured by different laboratories. Aiming at the evalution of the quality of these medicines, assays of in vitro dissolution and quantitative determination have been performed in 38 samples of tetracycline hydrochloride and phosphate and oxytetracycline hydrochloride capsules and docycycline hydrochloride coated tablet taken from 12 manufactures. The range of dissolution of the substance was determined in all the samples, according to the method recommended by USP XXIII. On the whole, only two of samples were rejected and all the others approved without restrictions, except four of them, wich required a retest. The evaluation of the individual values obtained in the assay of dissolution in each sample was significant, with a variation coefficient of up to 14.2%. The quantitative determination through the turbidimetric microbiological method employing Staphylococcus aureus ATCC 29737, resulted in two samples of tetracycline hydrochloride from the same manufatures with potency of 55.5 % and 68.7 % below the specified limit from 90 % to 125 % the labeled value. A comparative study of this method and the HPLC one was then performed. The USP XXIII method was chosen after a preliminary assay, followed by the determination of its validation parameters and system suitability. The established chromatographic method employed reversed phase column SYMMETRYTM C8 (octylsilane chemically bounded to totally porous sílica particles) and mobile phase consisting of ammonium oxalate 0.09 M, dimethyformamide and dibasic ammonium phosphate 0.18 M (63.9:32:4.7) adjusted to pH 7.6-7.7. The results confirmed the values obtained in the microbiological assay. When this method (HPLC) was used for the determination of 4-epianidrotetracycline, a maximum of 0.5 % was found, below the limit of 3% specified in the USP XXIII. The comparison between both methods reavealed constant superior results in the microbiological one, and the difference between the averages of the determinations from the methods was meaningful.
239

Avaliação das condições higiênico-sanitárias da alimentação servida às crianças em escolas do município de São José do Rio Preto - SP /

Werle, Catierine Hirsch. January 2011 (has links)
Orientador: Fernando Leite Hoffmann / Banca: Margarete Teresa Gottardo de Almeida / Banca: Maria Luiza Silva Fazio / Resumo: Os alimentos são passiveis de contaminação por diferentes agentes etiológicos que podem levar ao desenvolvimento de doenças afetando a saúde humana desencadeada por microrganismos patogênicos ou suas toxinas. O objetivo deste trabalho foi avaliar a merenda servida ás crianças, e as condições de preparo desta, através da análise microbiológica dos principais micro-organismos envolvidos em doenças transmitidas por alimentos.Este trabalho analisou 78 amostras de diferentes tipos de alimento servido para as crianças em 3 escolas do ensino infantil da cidade de São José do Rio Preto, 21 amostras de água utilizada no preparo da merenda e 29 amostras de Swab das mãos dos manipuladores. Avaliou-se a merenda foram quanto a presença de Salmonella spp., Escherichia coli, determinação do número mais provável de coliformes totais e termotolerantes, contagem de Bacillus cereus, Clostridios sulfito redutores, Staphylococcus coagulase positiva e bolores e leveduras. As amostras de água foram avaliadas quanto a contagem total de bactérias heterotróficas, coliformes totais, termotolerantes e pesquisa de E.coli. Investigou-se coliformes totais, termotolerantes, pesquisa de E.coli, contagem de Staphylococcus coagulase positiva e bolores e leveduras nas amostras de swab. Quando presentes cepas de E. coli e S. aureus foi realizado teste de sensibilidade a antimicrobianos. Para avaliação das condições de preparo da merenda realizou-se um check list nas cozinhas das escolas. 100% das amostras estavam de acordo com a legislação na contagem de Bacillus cereus, Clostridios sulfito redutores e pesquisa de Salmonella spp. 7,7% das amostras apresentaram contagens iguais ou superiores a 1100 NMP para coliformes totais, 1,3% não atendiam aos padrões estabelecidos para coliformes termotolerantes, em 6,4% das amostras foi detectado a presença de E.coli 1.3% apresentou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Foods are susceptible to contamination from different etiologic agents which can lead to the development of illnesses affecting human health triggered by pathogenic microorganisms or their toxins. The objective of the study is to evaluate the conditions in which the school meals are served to the children through a microbiological analysis of the principal food-related pathogens. This work analyzed 78 samples of different types of food served to children from 3 infant schools in the city of São José do Rio Preto, 21 water samples used in the preparation of school meals and 29 swab samples from the hands of the food handlers. The food samples were analyzed for the presence of Salmonella spp., Escherichia coli, the most probable number (MPN) of total and thermotolerant coliforms, the amount of Bacillus cereus, sulphite-reducing Clostridium, coagulase-positive Staphylococcus, mould and yeast. The water samples were tested for the total heterotrophic bacteria, total coliforms, thermotolerants, and traces of E. coli. The swab samples were analysed for total coliforms, thermotolerants, traces of E. coli, the amount of coagulase-positive Staphylococcus, mould and yeast. The strains of E. coli and S. aureus found were subjected to antimicrobial susceptibility testing. To evaluation of conditions of preparation of the meal took place a check list in school kitchens. 100% of the samples were in accordance with the legislation for the amount of Bacillus cereus, sulphite-reducing Clostridium and traces of Salmonella spp. 7.7% of the samples presented results equal to or above 1100 MPN for total coliforms while 1.3% did not comply with the standards established for thermotolerant coliforms. In 6.4% of the samples the presence of E. coli was detected; 1.3% presented results higher than 10 3 colony-forming units (CFU) for coagulase-positive Staphylococcus and 6.4% of the samples presented... (Complete abstract click electronic access below) / Mestre
240

Avaliação de métodos diretos e indiretos de diagnóstico da brucelose em cães naturalmente infectados / Evaluation of direct and indirect methods of diagnosis of brucellosis in naturally infected dogs

Lara Borges Keid 12 May 2006 (has links)
Foram comparados procedimentos laboratoriais diretos e indiretos aplicados ao diagnóstico da brucelose canina causada por Brucella canis. Foram examinados 196 cães, os quais foram classificados em infectados, suspeitos e não infectados, de acordo com resultados obtidos no cultivo microbiológico em amostras de sangue, sêmen e swab vaginal, no exame clínico e de acordo com dados epidemiológicos. Os resultados obtidos nos exames laboratoriais foram correlacionados com os resultados dos exames clínicos. As técnicas laboratoriais empregadas foram soroaglutinação rápida (SAR), soroaglutinação rápida com emprego do 2-mercaptoetanol (SAR-2ME), imunodifusão em gel de ágar (IDGA), cultivo microbiológico e PCR em amostras de sangue, sêmen e swab vaginal. Foram observados 41,83% de positivos pela SAR, 14,28% pela SAR-2ME, 28,14% pela IDGA, 32,14% pela hemocultura, 19,6% pelo cultivo microbiológico de sêmen, 4,82% pelo cultivo microbiológico de swab vaginal, 33,16% pela PCR em sangue, 33,33% pela PCR em sêmen e 26,89% pela PCR em swab vaginal. Os valores de sensibilidade das provas de SAR, SAR-2ME, IDGA, PCR em sangue e PCR em swab vaginal foram respectivamente de 81,25%; 42,18%; 75%; 89,06% e 54%. A especificidade dos métodos de SAR, SAR-2ME, IDGA, PCR em sangue e PCR em swab vaginal foram respectivamente de 81,25%; 100%; 100%; 97,21% e 97,14%. Nos cães machos, as proporções de resultados positivos diagnosticados pelo cultivo microbiológico de sêmen foram semelhantes às observadas pelos demais métodos de diagnóstico utilizados. As proporções de resultados positivos obtidos pelas técnicas de SAR, SAR-2ME, IDGA, hemocultura, PCR em sangue e cultivo de swab vaginal foram maiores dentre os animais que apresentaram sinais clínicos sugestivos de brucelose. Não houve associação entre a presença de sinais clínicos de brucelose e resultados positivos pelo cultivo microbiológico de sêmen e PCR em amostras de sêmen e swab vaginal. / Nine laboratory tests used for Brucella canis infection diagnosis in 196 dogs were evaluated: rapid slide agglutination test (RSAT), 2-mercaptoetanol rapid slide agglutination test (2ME-RSAT), agar gel immunediffusion test (AGID), microbiological culture of blood, semen and vaginal swab and PCR in blood, semen and vaginal swab samples. The results of the laboratorial tests used were compared to the results of clinical examination. A total of 41,83% of positives were detected by rapid slide agglutination test, 14,28% by 2-mercaptoetanol rapid slide agglutination test, 28,14% by agar gel immunediffusion test, 32,14% by blood culture, 19,6% by culture of semen, 4,82% by vaginal swab culture, 33,16% by PCR in blood samples, 33,33% by PCR in semen and 26,89% by PCR in vaginal swab samples. The sensitivity of RSAT, 2ME-RSAT, IDGA, PCR in blood and vaginal swab samples was respectively 81,25%; 42,18%; 75%; 89,06% and 54%. The specificity of RSAT, 2ME-RSAT, IDGA, PCR in blood and vaginal swab samples was respectively: 81,25%; 100%; 100%; 97,21% e 97,14%. In male dogs, the proportion of positive results detected by microbiological culture of semen was similar to the proportion of positive results detected by RSAT, AGID and blood culture, but the proportion was lower than that detected by PCR in semen. A higher proportion of positives were detected by RSAT, 2ME-RSAT, AGID, blood culture, PCR in blood samples and culture of vaginal swab, in animals presenting clinical signs of brucellosis. No association was observed between the presence of clinical signs of brucellosis and positive results by culture of sêmen and PCR in semen and vaginal swab samples.

Page generated in 0.0543 seconds