Spelling suggestions: "subject:"microdureza."" "subject:"icrodureza.""
111 |
Soldagem em laminas finas de hastelloy c-276 por laser pulsado Nd:YAGMunekata, Ricardo Mitsuo [UNESP] January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:12Z (GMT). No. of bitstreams: 0
Previous issue date: 2011Bitstream added on 2014-06-13T19:35:03Z : No. of bitstreams: 1
munekata_rm_me_ilha.pdf: 4705141 bytes, checksum: 56254cadfa4c90cb796f3b90671140ee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho estudou a influência da energia do pulso de soldagem, no caso processo laser de Nd:YAG operando no modo pulsado, na soldagem de duas lâminas finas com 100 μm de Hastelloy C-276, utilizado no revestimento de sensores que trabalham em ambiente corrosivo da indústria sucroalcooleira, química petroquímica e alimentícia. Utilizou-se energia de pulso de 1,0 Joule a 2,25 Joules, com incremento de 0,25 Joules com a velocidade de soldagem de (ν) taxa de repetição (Rr) fixas de 525mm/min e 39Hz respectivamente e largura temporal de 4 ms. As soldas foram realizadas com proteção gasosa de argônio. Foram realizadas análises macrográficas e micrográficas das juntas soldadas, através de secções transversais das mesmas e ensaios de microdureza Vickers e ensaio de tração. Os resultados obtidos mostraram que o controle da energia do pulso, em processo de soldagem por laser de lâminas finas é de fundamental importância para a geração de juntas soldadas livres de descontinuidades. Os parâmetros geométricos da junta soldada, tais como largura do cordão, largura de união e profundidade do cordão, aumentaram em função do aumento da energia do pulso. O processo mostrou-se muito sensível à formação de porosidade e à presença de gap entre as lâminas / This work measured experimental investigations were carried out using a pulsed neodymium: yttrium aluminum garnet laser welding to examine the influence of the pulse energy in two thin foil welding with 100 μm thickness, employed to cover sensors that work in corrosive environment of the sugar and alcohol industry,chemical petrochemistry and nourishing. The pulse energy was varied from 1,0 to 2,25 J at an increment of 0.25 J and an increment of 0.25 Joules with a welding speed and(ν) repetition rate (Rr) fixed 525mm/min and 39Hz respectively and 4 ms pulse duration. The specimens were laser-welded in an argon atmosphere. The welds were analyzed by macroscopic and microscopic observations using optical microscopy and micro hardness and tensile test. The results indicated that pulse energy control, in laser welding of thin foils, is of considerable importance for weld quality since it can generate discontinuities free weld joints. The geometric parameters of the welded joints like bead width, connection width and bead depth increased with the pulse energy increasing. The process showed very sensitive to porosity formation and gap between couple
|
112 |
Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splintsRodrigo Gonçalves Soares 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
|
113 |
Efeito da radioterapia sobre as propriedades mecânicas, químicas e morfológicas do esmalte e da dentina de dentes permanentes - Estudo in vitro / Effect of radiotherapy on the mechanical, chemical and morphological property of the enamel and of the dentine of permanent teeth - In vitro studyLigia Maria Napolitano Gonçalves 14 March 2012 (has links)
O presente estudo teve como objetivo avaliar, in vitro, os efeitos da radiação com cobalto-60 nas propriedades mecânicas, morfológicas e químicas do esmalte e da dentina de dentes permanentes através da: 1- microdureza longitudinal; 2- microscopia eletrônica de varredura (MEV); e 3- espectroscopia de energia dispersiva de raios X (EDX). A microdureza do esmalte e da dentina (n=12 hemissecções vestibulares) foi avaliada em três profundidades (superficial, média e profunda), antes e a cada 10 Gy de irradiação, até uma dose cumulativa de 60 Gy. A morfologia do esmalte e da dentina foi avaliada por meio de MEV (n=8 hemissecções), em 2 hemissecções vestibulares irradiadas com dose cumulativa de 30 Gy, 2 hemissecções vestibulares irradiadas com dose cumulativa de 60 Gy e 4 hemissecções palatinas não irradiadas. A composição química do esmalte e da dentina foi avaliada por meio de EDX (n=4 hemissecções), utilizando-se as mesmas hemissecções previamente submetidas à MEV (com dose cumulativa de 60 Gy de irradiação, e nas hemissecções não irradiadas). Os dados foram analisados quanto à sua distribuição e submetidos à Análise de Variância a dois critérios. Para a diferenciação das médias, empregou-se o teste de Fisher. O nível de significância adotado foi de 5%. Com relação à microdureza no esmalte, pôde-se observar que houve diferença estatisticamente significante entre os grupos (p < 0,05). A microdureza no esmalte não irradiado não apresentou diferença estatisticamente significante em comparação com a do esmalte após irradiação com doses de 40, 50 e 60 Gy (p > 0,05), e apresentou-se maior que os valores de microdureza nas doses de 10, 20 e 30 Gy (p < 0,05). Com relação à microdureza nas diferentes profundidades pôde-se observar diferença significante (p < 0,05) entre elas, observando-se no esmalte superficial seus maiores valores. Na análise morfológica do esmalte observou-se que os espécimes irradiados apresentaram alterações crescentes, em função do aumento da dose de radiação, em comparação ao esmalte não irradiado. A porção interprismática tornou-se mais evidente após as doses de 30 e 60 Gy. Em relação à microdureza da dentina, pôde-se observar que houve diferença significante entre os grupos (p < 0,05). A microdureza na dentina não irradiada não apresentou diferença estatisticamente significante em comparação com a microdureza na dose de 40 Gy (p > 0,05) e apresentou valores superiores aos observados nas doses de 10, 20, 30, 50 e 60 Gy (p < 0,05). Em relação à microdureza nas diferentes profundidades avaliadas pôde-se observar diferença significante (p < 0,05) entre elas, sendo que a dentina média apresentou seus maiores valores. Na análise morfológica da dentina observou-se a presença de fendas na estrutura dentinária, túbulos dentinários colabados/destruídos e fragmentação das fibras colágenas nas doses de 30 e 60 Gy, sendo as alterações mais intensas com aumento da dose de irradiação, para todas as regiões analisadas, em comparação à dentina não irradiada. Na análise química do esmalte e da dentina irradiados observou-se discreto aumento de oxigênio (O) e diminuição de fósforo (P) e cálcio (Ca), em comparação aos espécimes não irradiados. Os resultados permitiram concluir que a radioterapia não influenciou a microdureza do esmalte, como um todo, entretanto, quando analisou-se nas diferentes profundidades do esmalte, verificou-se um aumento da microdureza na região superficial. Na dentina, a radioterapia ocasionou diminuição da microdureza após praticamente todas as doses de radiação, em comparação à dentina não irradiada, sendo que na região da dentina média observaram-se seus menores dos valores. As alterações morfológicas das estruturas do esmalte e da dentina foram crescentes com o aumento das doses de irradiação observando-se a porção interprismática mais evidente, presença de fendas e túbulos dentinários colabados/destruídos e fragmentação progressiva das fibras colágenas. Quimicamente, após a irradiação, tanto no esmalte como na dentina, observouse um discreto aumento na porcentagem de oxigênio e redução nas porcentagens de fósforo e cálcio. / The present study had as objective to evaluate, in vitro, the effect of the radiation of 60 Cobalt (Co 60) in the mechanical, morphological and chemical properties of the enamel and of the dentine of permanent teeth by means of: 1- longitudinal microhardness; 2- scanning electron microscopy (SEM); and 3; energy dispersive X-ray spectroscopy (EDX). The microhardness of the enamel and of the dentine (n = 12 vestibular hemisections) was evaluated in three depths (superficial, medium and deep), before and at each 10 Gy of irradiation, until a total cumulative dose of 60 Gy. The morphology of the enamel and of the dentine was evaluated by means of a SEM (n = 8 hemisections), in 2 irradiated vestibular hemisections with total cumulative dose of 30 Gy, 2 irradiated vestibular hemisections with total cumulative dose of 60 Gy and 4 not irradiated palatine hemisections (control). The chemical composition of the enamel and of the dentine was evaluated by means of EDX (n = 4 hemisections), using the same hemisections previously submitted to SEM (with cumulative dose of 60 Gy of irradiation, and in the not irradiated hemisections). The data were analyzed about their distribution and submitted to the Analysis of Variance at two criteria. For the differentiation of the averages, the test of Fisher was used. The level of significance adopted was of 5%. About the longitudinal microhardness in the enamel, it was possible to be observed that there was no statistically significant difference between the groups (p < 0,05). The microhardness in the not irradiated enamel was similar to the enamel after the irradiation with doses of 40, 50 and 60 Gy (p > 0,05) and higher than the microhardness values in the doses of 10, 20, e 30 Gy (p < 0,05). About the microhardness in the different depths it was observed significant difference (p < 0,05) between them, being observed in the superficial enamel the greatest values of microhardness. In the morphological analysis of the enamel it was observed that the irradiated specimens presented growing alterations, due to the increase of the radiation dose, comparing to the not irradiated enamel. There was no difficulty in observing the prisms and the crystals after the irradiation, however the interprismatic portion became more evident after the radiation doses of 30 and 60 Gy. About the longitudinal microhardness of the dentine, it could be observed that there was significant difference between the groups (p < 0,05). The microhardness of the not irradiated dentine was not statistically significant compared to the microhardness in the dose of 40 Gy (p > 0,05) and it presented higher values to the observed ones in the doses of 10, 20, 30, 50 and 60 Gy (p < 0,05). About the relation to the microhardness in the different evaluated depths it was possible to observe significant difference (p < 0,05) among them, being that the medium dentine presented the highest values of microhardness. In the morphological analysis of the dentine it was observed the presence of cracks in the dentine structure, collapsed/destroyed dentine tubules and fragmentation of the collagen fibers in the doses of 30 and 60 Gy, being the alterations more intense with the increase of the dose of irradiation, for all the analyzed regions, comparing to the not irradiated dentine. In the chemical analysis of the irradiated enamel and the dentine it was observed the slight increase of oxygen (O) and decrease of phosphorus (P) and Calcium (Ca), comparing to the not irradiated specimens. The result allowed to be concluded that the radiotherapy occasioned the decrease of the microhardness of the enamel after the doses from 10 to 30 Gy, but in the following doses there was an increase of the microhardness, which became similar to the not irradiated enamel, being that in the superficial region it was observed the biggest increase of the microhardness. In the dentin, the radiotherapy caused decrease of the microhardness after practically all doses of radiation, comparing to the not irradiated dentine, being that in the region of the medium dentine the lowest values of microhardness were observed. The morphological alterations of the enamel and of the dentine structure were growing with the increase of the radiation doses observing the more evident interprismatic portion, presence of cracks and collapsed/destroyed dentine tubules and progressive fragmentation of collagen fibers. Chemically, after the irradiation, not only in the enamel but also in the dentin, it was observed a slight increase of percentage of the oxygen and decrease in the percentages of phosphorus and calcium.
|
114 |
Caracterização das camadas formadas pela nitretação a plasma de ferro sinterizado / CHARACTERIZATION OF LAYERS FORMED BY PLASMA NITRIDING AT SINTERED IRONFontes, Marcos Alves 06 March 2012 (has links)
Made available in DSpace on 2016-06-02T19:12:21Z (GMT). No. of bitstreams: 1
4512.pdf: 12085865 bytes, checksum: 9c98b7edb2a0238a143b2c8e9469a515 (MD5)
Previous issue date: 2012-03-06 / Ion nitriding is a process of thermo-physical-chemical treatment that provides a surface hardening, originated by interstitial diffusion of nitrogen on the ferrous and nonferrous alloys surfaces. Understanding and controlling the formation of the nitrided layer have considerable industrial interest due to the improvements regarding wear, corrosion and fatigue resistances on the metals and their alloys. In this work, it was performed the surface modification in sintered iron samples by ion nitriding process, with a gaseous mixture of 80% vol H2 and 20% vol N2, during times of 3 and 5 hours, using ion nitriding temperature of 500°C, 540°C and 580°C. The samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analyses, and wear and micro-hardness tests, comparing the results with sintered and steam treatment samples. The results showed that both nitride thickness and wear resistance increased with higher nitriding time and temperature, where the temperature was the variable that most influenced the aforementioned characteristics. The XRD analysis indicated that the nitrided layer near to the surface, for all samples, consisted in a mixture of y-Fe4N and e-Fe3N phases. / A nitretação iônica é um processo de tratamento termo-físico-químico que consiste em um endurecimento superficial, provocado pela difusão intersticial de nitrogênio atômico na superfície de ligas ferrosas e não ferrosas. O entendimento e o controle da formação da camada nitretada apresentam considerável interesse industrial devido às melhorias alcançadas nas resistências ao desgaste, corrosão e à fadiga dos metais e suas ligas. Neste trabalho, promoveu-se a modificação superficial de amostras de ferro sinterizado por meio do processo de nitretação a plasma, com uma mistura gasosa de 80% vol H2 e 20% vol N2, nos tempos de 3 e 5 horas, e temperaturas de nitretação de 500°C, 540°C e 580°C. As amostras foram caracterizadas por meios de análise de microscopia eletrônica de varredura (MEV) e difração de raios X (DRX), e quantificadas quanto aos níveis de desgaste e microdureza, em comparação com amostras sinterizada e ferroxidada. Os resultados mostraram que tanto as espessuras das camadas de nitretos como as resistências ao desgaste das amostras aumentaram com o tempo e temperatura de nitretação, sendo a temperatura a variável que mais influenciou nas características mencionadas. A análise de DRX indicou que a camada nitretada próxima a superfície, para todas as amostras, consiste de uma mistura de fases de  -Fe4N e -Fe3N.
|
115 |
Caracterização magnética de aço com a superfície endurecidaSilva, Gustavo Rodrigues da 03 December 2010 (has links)
Neste trabalho foram investigadas as propriedades magnéticas (curva de histerese e ruído Barkhausen) de alguns aços (ABNT 1045, 1050 e 1548) cujas superfícies foram endurecidas por indução. O objetivo era de desenvolver um ensaio não-destrutivo para determinar a espessura da camada endurecida, assim evitando a necessidade de realizar medidas (destrutivas) de microdureza. Medidas da susceptibilidade magnética mostraram um pico (ferrita) em torno de 800 A/m e outro (martensita) em torno de 3500 A/m. Assim procuramos correlacionar a amplitude do pico de ferrita com a espessura da camada dura na superfície. Para esta finalidade foram desenvolvidos sensores para medir ruído Barkhausen e um filtro para o processamento do sinal. Foi possível correlacionar medidas de microdureza com algumas características observadas nas medições magnéticas, como, por exemplo, a amplitude do sinal de ruído Barkhausen e o campo magnético do pico do sinal Barkhausen. Deste modo, encontrou-se uma relação entre a amplitude do ruído Barkhausen e a espessura da camada superficial. Seria desejável complementar essas medidas com outras e sugestões para uma continuação do trabalho são detalhadas. / Submitted by Marcelo Teixeira (mvteixeira@ucs.br) on 2014-06-03T20:29:34Z
No. of bitstreams: 1
Dissertacao Gustavo Rodrigues da Silva.pdf: 8142476 bytes, checksum: 29c4748e15d0fbcc852d788b9f1fa011 (MD5) / Made available in DSpace on 2014-06-03T20:29:34Z (GMT). No. of bitstreams: 1
Dissertacao Gustavo Rodrigues da Silva.pdf: 8142476 bytes, checksum: 29c4748e15d0fbcc852d788b9f1fa011 (MD5) / This work investigates the magnetic properties (hysteresis loop and Barkhausen noise) in some steels (ABNT 1045, 1050 and 1548) whose surfaces had been hardened by induction. The goal was to develop a non-destructive test procedure to determine the thickness of the hardened layer, thus avoiding the need to perform (destructive) measurements of the microhardness. Measurements of the magnetic susceptibility showed a peak (ferrite) around 800 A / m and other (martensite) at around 3500 A / m. Therefore, a correlation was sought between the peak amplitude of ferrite with the thickness of hard layer on the surface. For this purpose sensors were developed to measure Barkhausen noise as well as a filter for signal processing. It was possible to correlate measurements of microhardness with some features observed in magnetic measurements, for example, the amplitude of the Barkhausen noise and magnetic field of peak Barkhausen signal. Thus, a relationship was found between the amplitude of the Barkhausen noise and the thickness of the surface layer. It would be desirable to supplement these with other measurements and suggestions for further work are detailed.
|
116 |
Polimerização com laser de argônio: influência na tensão de contração, microdureza, resistência flexural e módulo de elasticidade de uma resina composta / Polymerization with the argon laser: Influence on shrinkage stress microhardness, percentage of maximum hardness, flexural strength and flexural modulus of a composite resinCarina Sinclér Delfino 19 September 2008 (has links)
O objetivo desse estudo foi verificar a influência da fotoativação com laser de argônio na tensão de contração (TC), microdureza (M), porcentagem de dureza máxima (PDM), resistência flexural (RF) e módulo de elasticidade (ME) de uma resina composta híbrida. A fotoativação foi realizada com laser de argônio 200mW por 10 segundos (L1), 200mW por 20 segundos (L2), 250mW por 10 segundos (L3) e 250mW por 20 segundos (L4). Como controle foi utilizada a luz hálógena por 20 segundos (H). A TC foi monitorada por 5 minutos em corpos-de-prova com 5mm de diâmetro e 1mm de altura. A M e a PDM foram obtidas em corpos-de-prova com 2mm de espessura após 7 dias a 37°C. Para obtenção da RF e do ME foram confeccionados corpos-de-prova nas dimensões 10 X 2 X 1mm (comprimento, largura e espessura), testados após 24h a 37°C. Os dados obtidos foram analisados por ANOVA/Teste de Tukey (p<0,05). Os valores de TC (MPa) foram estatisticamente mais baixos para o grupo L3 (1,3)c, seguido pelos grupos L1(2,7)b, L4 (3,4)a,b, L2 (3,7)a e H (4,5)a. Para os valores de M não houve diferença estatisticamente significante quando o mesmo tempo de fotoativação foi utilizado, sendo L1= 70,1a, L2= 78,1b, L3= 69,9a, L4= 78,1b e H= 79,9b. Todos os grupos apresentaram uma PDM de no mínimo 80%. Apenas o grupo L1 apresentou diferença estatisticamente significante na RF (MPa) e no ME (GPa), 86,2 e 5,4 respectivamente, sendo inferior. Dentro dos grupos estudados, o L3 apresentou propriedades mecânicas adequadas e mínima tensão de contração, além de possibilitar redução do tempo clínico para fotoativação de restaurações com a resina testada em 50%. / The objective of this study was to verify the influence of photoactivation with the argon ion laser on shrinkage stress (SS), followed by evaluation of Vickers microhardness (VM), percentage of maximum hardness (PMH), flexural strength (FS) and flexural modulus (FM) of a composite resin. Methods: The light curing units used were argon ion laser and halogen light. The groups were: L1- laser at 200mW for 10 seconds; L2- laser at 200mW for 20 seconds; L3- laser at 250mW for 10 seconds; L4- laser at 250mW for 20 seconds; and H- halogen light at 275mW for 20 seconds. The SS was monitored for 5 minutes in samples 5-mm in diameter by 1-mm in height. The VM and PHM were obtained in samples with a thickness of 2-mm after 7 days at 37°C. To FS and FM the samples were prepared using a stainless steel mold 10 x 2 x 1mm (length, width and height) and measured after 24h storage at 37°C. Data were analyzed by ANOVA/Tukey`s test (p<0.05). Results: The values of SS (MPa) were statistically lower for the group L3(1.3)c, followed by groups L1(2.7)b, L4 (3.4)a,b, L2(3.7)a and H(4.5)a. To the values of VM there was no difference when the same time of photo activation was used, being L1= 70.1a, L2=78.1b, L3= 69.9a, L4= 78.1b and H= 79.9b. All groups showed a PMH of at least 80%. Only the group L1 showed difference in FS (MPa) and FM (GPa), 86.2 and 5.4 respectively, being lower. Conclusion: within the studied groups, the L3 group presented adequate mechanical properties and minimum SS, reducing the clinical working time for photo activation of restorations with the tested resin in 50%.
|
117 |
\"Estudo do efeito da distância da ponta de aparelhos fotoativadores na microdureza e no grau de conversão da resina composta usando luz halógena, laser de argônio e LED\" / Study of the effect of light curing tip distance on microhardness and on degree of conversion of a composite resin using halogen light, argon laser and LED.Kátia Martins Rode 16 February 2007 (has links)
O objetivo desse estudo foi avaliar o efeito da distância da ponta fotoativadora na profundidade de polimerização da resina composta por meio de testes de microdureza Vickers e da análise do grau de conversão pelo método FT-Raman. O aparelho de luz halógena (500 mW/cm2) e o LED (900 mW/cm2) foram utilizados na sua intensidade convencional. O laser de argônio, na potência de 250 mW. Os tempos de fotoativação foram de 40 segundos para a luz halógena, 20 segundos para o LED e 20 e 30 segundos para o laser. E as distâncias da ponta fotoativadora foi padronizada com anéis de 3, 6 e 9 mm de altura. A resina composta micro-híbrida foi inserida em porção única, em matrizes de polipropileno pretas com as espessuras de 1 a 4 mm. Os corpos-de-prova foram armazenados por uma semana a seco, a 37ºC em recipientes protegidos da luz. Os dados da microdureza e do grau de conversão foram analisados separadamente por meio da análise de variância e teste de Tukey, com nível de significância de 5% e depois correlacionados pelo teste de correlação de Pearson. Os resultados obtidos permitiram concluir que: o aumento da distância da fonte de luz promoveu uma diminuição nos valores de microdureza e no grau de conversão para todos os tipos de fontes de luz estudados e o mesmo ocorreu com o aumento da espessura de resina composta diminuindo também os valores de microdureza e grau de conversão. Houve uma alta correlação entre a análise PDM (porcentagem de dureza máxima) e a análise do grau de conversão e entre o teste de microdureza e a análise do grau de conversão. As fontes de fotoativação estudadas promoveram grau de conversão e microdureza correspondentes entre si, desde que a espessura da resina fosse de 1 mm de espessura e a que a fonte estivesse a uma distância máxima de 3 mm. / This study evaluated the influence of curing tip distance on cure depth of a composite resin, measuring the Vickers microhardness and determining the degree of conversion, using FT-Raman spectroscopy. The halogen light (500 mW/cm2) and the LED (900 mW/cm2) were used with conventional intensity of power and the argon laser with 250mW. The exposure time was 40 seconds to halogen light, 20 seconds to LED and 20 and 30 seconds to Argon laser. And the curing tip distances used (0, 3, 6 e 9 mm) were controlled by metals rings. The composite was placed in one increment, in a black polipropilen matrix with thickness of the 1 to 4 mm. The specimens were stored for one week in dry stove, for 37ºC in containers protect from the light. The values of microhardness and degree of coonversion were analyzed separately by ANOVA (Analysis of variance) and Tukey test, with significance level for 5%. Then, the correlation was analyzed by Pearson test. The results obtained conclude that: the increased of tip distance produced a decreased in microhardness and degree of conversion values; the microhardness and degree conversion values decreased as the thickness increased; it showed a higher correlation between the qualities of polymerization and the degree of conversion and between the microhardness test and the degree of conversion. The present study suggests that the units of polymerization studied produced microhardness and degree of conversion values that corresponded to each other, only with 1mm of thickness and using a tip distance of 3 mm, at most.
|
118 |
Estudo da progressão e inibição de lesões artificiais de cárie através de alterações da microdureza superficial / Progression and inhibition of artifical caries lesions in human and bovine substrate evaluated by surface microhardnessFrancisco Carlos Rehder Neto 29 January 2009 (has links)
Os objetivos do presente estudo foram avaliar a progressão e a inibição de lesões artificiais de cárie comparando-se substrato humano e bovino, e também avaliar potenciais agentes remineralizantes no controle da progressão destas lesões. Este trabalho foi divido em duas partes. Inicialmente, para validar o modelo de indução das lesões e comparar o substrato humano ao bovino, sessenta fragmentos de esmalte (30 humanos e 30 bovinos) e 60 fragmentos de dentina (30 humanos e 30 bovinos) medindo 4x4x2 foram embutidos, planificados e polidos e avaliados quanto à microdureza superficial (MDS, Knoop) utilizando-se carga estática e tempo de aplicação de 25g, por 5s para esmalte e 10 g por 10 segundos para dentina. Lesões incipientes de cárie foram induzidas através de um modelo de ciclos de pH. Os espécimes foram imersos por 1 hora em solução desmineralizante e por 22 horas em solução remineralizante, o que correspondia a um ciclo de pH. Novas medidas de MDS foram realizadas ao final de cada ciclo de pH, sendo que para dentina foram realizados 3 ciclos e para esmalte 8 ciclos. A Análise de Variância (ANOVA) foi conduzida seguindo-se o delineamento fatorial, 2x9, para esmalte; e 2x4 para dentina. Análises de Regressão foram utilizadas para determinar a equação do modelo que rege a perda de conteúdo mineral ao longo do tempo de indução das lesões de cárie. A Análise de Variância (ANOVA) demonstrou diferenças altamente significativas para o fator substrato (p<0,01) e para o fator ciclo (p<0,01) para ambos os substratos testados. Para o fator ciclo, a Análise de Regressão revelou que as funções que regem o comportamento da KHN ao longo do desafio cariogênico apresentaram como melhor ajuste, funções exponenciais, para todos os substratos testados. A segunda etapa deste trabalho objetivou avaliar a progressão de lesões artificiais de cárie em esmalte bovino, na presença ou ausência de agentes potencialmente remineralizantes. Fragmentos de esmalte bovino foram preparados e selecionados quanto a sua microdureza inicial. Lesões incipientes de cárie foram induzidas através de um modelo de ciclos de pH. Novas medidas de MDS foram realizadas (MDSpós-lesão). Instituíram-se, então, os seguintes tratamentos com: 1) dentifrício regular (RE, 1.100 ppm F, Sensodyne, GSK); 2) dentifrício contendo um vidro bioativo (VB, Oravive); 3) pasta à base de fosfato de cálcio amorfo, estabilizado por fosfopeptídeo de caseína (CPP-ACP, MI Paste, GC America) 4) CPP-ACP contendo 900 ppm F (MI Plus Paste, GC America). O grupo controle não foi exposto a qualquer agente potencialmente remineralizante (n=15). Aplicaram-se os tratamentos cinco vezes, sendo estes intercalados por um novo desafio cariogênico. Mensurou-se a MDSfinal. A ANOVA revelou diferença significativa entre os tratamentos (p = 0,0161). O Teste de Tukey foi aplicado e a diferença percentual na perda de conteúdo mineral calculada através da seguinte sentença [(MDSfinal MDSpós-lesão)/ MDSpós-lesão]/100. Os espécimes expostos ao VB (+7,1%), RE (+6,7%) e CPP-ACP+F (+3,8%) apresentaram menor perda mineral em relação àqueles que serviram como controle (-11,0%). O grupo CPP-ACP (+3,2%) diferiu do grupo controle e dos grupos VB e RE, apresentando resultado semelhante ao grupo CPP-ACP+F. Conclui-se que, o substrato bovino apresentou comportamento semelhante ao humano quanto à progressão de lesões artificiais de cárie, podendo ser considerado como uma opção viável em estudos sobre cárie dental e que na dependência do agente utilizado, pode haver efeito remineralizante, que se reflete no controle da progressão de lesões de cárie. / The aim of the study was to compare caries-like lesions progression in human and bovine substrate, and also investigate pastes containing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and calcium sodium phosphosilicate (VB) as remineralising agents to control caries lesion progression. This work was divided into two parts. Initially, the model for caries lesions induction was tested and human and bovine substrates were compared. Sixty specimens of enamel (30 bovine and 30 human) and sixty dentin specimens (30 bovine and 30 human) were submitted to a pH cycle protocol to induce artificial caries lesions. Human and bovine specimens were pretested for Knoop microhardness under 25 g load applied for 5 s for enamel and 10 g load applied for 10 s for dentin. Each pH cycle consisted of immersion of the specimens for 1 hour in demineralizing solution and 22 hours in remineralising solution, for eight days for enamel and for three days for dentin. Surface Knoop microhardness (SMH) was daily measured at each pH cycle conduced. Data were analyzed by ANOVA as a factorial design (2x9) for enamel, and (2x4) for dentin substrate. Regression analyses were used to model the SMH values of human and bovine (enamel and dentin) over the time. Regression analyses of the data showed that the SMH values for both human and bovine (enamel and dentin) decreased in an exponential model with the number of pH cycles. The second stage of this work aimed to evaluate the progression of artificial caries lesions in bovine enamel in the presence or absence of potentially remineralising agents. Enamel slabs of bovine teeth were embedded in polyester resin and had their enamel surfaces serially polished, and tested for surface microhardness (SMH) with a static load of 25 g applied for 5 s. After preformed incipient caries-like lesions they were evaluated by microhardness (SMHpost-lesion) and randomly assigned to five treatment groups(n=15): 1) regular dentifrice (RE, 1.100 ppm F, Sensodyne, GSK); 2) dentifrice with bio glass (VB, Oravive); 3) amorphous calcium phosphate stabilized by casein phosphopeptide (CPP-ACP, MI Paste, GC America); 4) CPP-ACP with 900 ppm F (MI Plus Paste, GC America) and 5) Control group not exposed to any remineralising agent (n=15). Treatments were applied five times, after the demineralization period in the cariogenic challenges. Post-treatments SMH measurements were conduced (SMHpost-tratment). The ANOVA applied to the percentage difference between SMH post-treatment/SMHpost-lesion, reveals a significant difference among the treatments (p=0.0161). The specimens exposed to VB (7.1%), RE (6.7%) and CPP-ACP+F (3.8%), showed lower mineral loss content in relation to those that was used as a control group (-11.0%). The group CPP-ACP (3.2%) did not differed from the other groups. In conclusion, since the bovine substrate presents some advantageous characteristics over the human substrate and the similar behavior observed between both substrates for enamel and dentin. The use of bovine tooth can be considered a viable and practical alternative to human tooth in dental caries research and for the second stage the remineralizing effect seems to be dependent of the remineralizing agent used, which reflects over the control of caries lesions progression.
|
119 |
Comparação in vitro de parâmetros para fotoativação de restaurações em resina composta por meio de microdureza e microscopia eletrônica de varredura / In vitro comparison of parameters for photoactivation of composite resin restorations using hardness and scanning electron microscopyCarlos Alberto Kenji Shimokawa 13 September 2013 (has links)
Este estudo in vitro teve como objetivo a comparação de diferentes protocolos para fotoativação de restaurações em resina composta por meio de teste de microdureza e análise da adaptação marginal com microscopia eletrônica de varredura. Foram confeccionadas restaurações de 2mmx4mmx2mm com a resina composta Premisa (Kerr) em 30 dentes bovinos. Durante o procedimento restaurador, o método de fotoativação teve variação, sendo um grupo ativado com o método contínuo (grupo controle) durante 20 segundos, utilizando o fotoativador Elipar Freelight 2; outro grupo utilizou o mesmo equipamento fotoativador, com variação da distância da ponta ativadora, a fim da promoção de um método soft-start (grupo soft-start), tendo distância inicial de 6mm por 20 segundos, seguido de distância mínima por mais 10 segundos; e um terceiro grupo utilizou a tecnologia PLS (grupo DEMI), fornecida pelo equipamento DEMI, que fornece uma luz pulsada e permite a polimerização adequada de uma resina composta em 5 segundos (segundo o fabricante). Após 24 horas de restaurados, mantidos em estufa a 37ºC, os dentes foram seccionados no sentido inciso cervical resultando em 60 corpos de prova, sendo metade deles utilizados em cada teste (N=10). As metades tiveram as superfícies correspondentes ao corte transversal lixadas até a obtenção de superfícies planas e polidas, sendo que 30 delas foram selecionadas aleatoriamente para o teste de microdureza Knoop em 3 diferentes profundidades e as outras 30 metades foram replicadas em resina epóxica para leitura em microscopia eletrônica de varredura. Com as imagens obtidas foram feitas medidas de porcentagem de perímetro de restauração com desadaptação marginal e largura da maior fenda encontrada. Foram aplicados testes estatísticos de análise de variância split plot para os resultados de dureza e one way para a adaptação marginal. Em relação à dureza, os testes mostraram não haver diferença estatisticamente significante entre os grupos avaliados, enquanto houve diferença nas diferentes profundidades (p<0,0001), sendo a dureza na região profunda maior do que na média, que foi maior do que na superficial. Para a adaptação marginal, os testes não mostraram diferença estatisticamente significante para a largura de maior fenda encontrada entre os grupos controle e DEMI, somente o grupo soft-start foi diferente dos outros grupos (p=0,0064), tendo ele os menores valores. Apesar de a porcentagem de perímetro com desadaptação marginal ter apresentado valores com grandes valores de desvio padrão, foi encontrada diferença estatisticamente significante entre os grupos controle e DEMI, mas não entre os grupos DEMI e soft-start. O teste de correlação de Pearson demonstrou correlação linear positiva entre largura da maior fenda encontrada e porcentagem de perímetro com desadaptação marginal. Foi possível a conclusão de que o protocolo de fotoativação soft-start melhorou a adaptação marginal das restaurações em resina composta, sem alterar a dureza do material; o equipamento fotoativador DEMI, com a utilização da tecnologia PLS, teve resultados sem diferença estatisticamente significante na avaliação da adaptação marginal, quando comparados ao grupo controle; nenhum dos protocolos de fotoativação testados causou alteração na dureza da resina composta fotoativada, quando comparadas entre si, havendo aumento dessa propriedade conforme houve aumento da profundidade. / This in vitro study aimed to compare different protocols for the photoactivation of composite resin restorations using microhardness test and analysis of marginal adaptation with scanning electron microscopy. Restorations with 2mmx4mmx2mm were made in 30 bovine teeth using the composite resin Premisa (Kerr). During the restorative procedure, the polymerization method had change, being one group activated with the continuous method (control group) for 20 seconds using the curing unit Elipar Freelight 2, another group used the same curing unit equipment, varying the distance from the activator tip in order to promote a soft-start method (soft-start group), with initial distance of 6mm for 20 seconds, followed by minimum distance for 10 seconds, and a third group used technology PLS (DEMI group) supplied from the DEMI, which provides a pulsed light and allows an adequate polymerization of a resin composite in 5 seconds (according to manufacturer). 24 hours after restoration, maintained at 37 ° C, the teeth were sectioned incisocervical towards resulting in 60 specimens, half of them being used in each test (N = 10). The halves were sanded on the transversal section surfaces to obtain flat and polished surfaces, of which 30 were randomly selected for Knoop microhardness testing in 3 different depths and the other 30 halves were replicated in epoxy resin for microscopy scanning electron reading. Measures of percentage of perimeter with marginal desadaptation and width of the largest slot found were made with the obtained images. Split plot analysis of variance tests were applied to hardness results and one way to the marginal adaptation. Regarding the hardness, tests showed no statistically significant difference among the groups, while there were differences at different depths (p<0,0001), being the hardness of the deep region highest than the medium, which was higher than the superficial. For marginal adaptation, tests showed no statistically significant difference for the width of the largest slot found between the control group and DEMI, only the soft-start group was different from the other groups (p=0,0064), having the lowest values. Despite the large standard deviations shown by the percentage of perimeter with marginal desadaptation, statistically significant difference was found between the control and DEMI, but not between groups DEMI and soft-start. The Pearson correlation test showed positive linear correlation between the width of the largest slot found and the percentage of perimeter with marginal desadaptation. It was possible to conclude that the soft-start photoactivation protocol improved the marginal adaptation of composite resin restorations, without changing the hardness of the material; DEMI curing unit equipment, using PLS technology, showed no statistically significant difference in the evaluation of marginal adaptation, comparing with the control group; none of the protocols tested photoactivation caused change in hardness of composite resin when compared to each other, with an increase of this property as the depth increased.
|
120 |
Determinação de parâmetros seguros e efetivos do laser de CO2 (?= 10,6 ?m) na redução da desmineralização da dentina radicular - Estudo in vitro / Determination of safe and effective parameters of CO2 laser (?= 10.6 ?m) on the reduction of root dentin demineralization - an in vitro studyWanessa Christine de Souza Zaroni 28 June 2007 (has links)
Estudos têm mostrado que a dentina pode ser modificada pelo laser pulsado de CO2 tornando-a um substrato mais ácido-resistente. Este estudo in vitro se propôs a estabelecer parâmetros seguros e efetivos de um laser pulsado de CO2 com comprimento de onda 10,6 ?m e avaliou seu efeito sobre a morfologia superficial e a composição química, assim como sobre a redução da desmineralização da dentina radicular. Noventa e cinco superfícies radiculares humanas obtidas de quarenta e oito terceiros molares foram aleatoriamente divididas em 5 grupos (n=15 para o grupo de controle e n=20 para os grupos irradiados com laser): G1 - Nenhum tratamento (controle), G2 - 2,5 J/cm2, G3 - 4,0 J/cm2, G4 - 5,0 J/cm2 e G5 - 6,0 J/cm2. A temperatura intrapulpar foi mensurada por meio de análise termográfica com termômetro de radiação infravermelha, as modificações químicas, por meio de espectroscopia FT-Raman e as alterações morfológicas por meio de microscopia eletrônica de varredura. Após o tratamento da superfície, os espécimes foram submetidos a 7 dias de ciclagem de pH, permanecendo diariamente em soluções desmineralizadora e remineralizadora por 3 h e 21 h, respectivamente. Após o desafio ácido, os espécimes foram seccionados e a perda mineral foi determinada por meio do teste de microdureza Knoop (5 g, 5 seg) em profundidades pré-determinadas em relação à superfície de dentina radicular (20 ?m - 275 ?m). Para todos os grupos irradiados, as mudanças de temperatura intrapulpar mostraram-se abaixo de 0,9°C. A espectroscopia FT-Raman não evidenciou alterações químicas entre os espécimes não-irradiados e os irradiados com laser de CO2. Entretanto a análise em microscópio eletrônico de varredura indicou que as densidades de energia a partir de 4,0 J/cm2 foram suficientes para induzir mudanças morfológicas na dentina radicular. Adicionalmente, para as densidades de energia iguais ou superiores a 4,0 J/cm2, foram observados efeitos de redução da desmineralização da dentina radicular induzidos pela irradiação laser. Pode-se concluir que densidades de energia em torno de 4,0 a 6,0 J/cm2 podem ser aplicadas à dentina radicular, a fim de promover mudanças morfológicas e reduzir a reatividade ácida da mesma, sem comprometer a vitalidade pulpar. / Studies have shown that dentin can be modified by pulsed CO2 laser to form a more acid-resistant substrate. This in vitro research aimed to establish safe parameters of a pulsed study 10.6 ?m CO2 laser and evaluate its effect on chemical and morphological features in dentinal surface, as well as on the reduction of root dentin demineralization. Ninety five human root surfaces obtained from forty eight third molars were randomly divided in 5 groups (n=15 for control group and n=20 for laser groups): G1 - No treatment (control), G2 -2.5 J/cm2, G3 - 4.0 J/cm2, G4 - 5.0 J/cm2 and G5 - 6.0 J/cm2. Intrapulpal temperature was evaluated during dentin irradiation by an infrared thermometer, chemical modifications by FT-Raman spectroscopy, and morphological modifications by SEM. After the surface treatment, the specimens were submitted to a 7 days pH-cycling model, consisted of the daily immersion in demineralizing and remineralizing solutions for 3 h and 21 h, respectively. After the acid challenge, the specimens were sectioned and the mineral loss was determined by means of cross-sectional Knoop microhardness (5 g, 5 sec) at different depths from the dentin root surface (20 ?m - 275 ?m). For all irradiated groups, intrapulpal temperature changes were below 0.9°C. FT-Raman spectroscopy did not show chemical changes in the irradiated specimens. However, scanning electron microscopy images indicated that fluences as low as 4.0 J/cm2 were sufficient to induce morphological changes in root dentin. Additionally, for fluences reaching or exceeding 4.0 J/cm2, laser-induced inhibitory effects on root dentin demineralization were observed. It was thus concluded that the laser energy density in the range of 4.0 to 6.0 J/cm2 could be applied to dental root dentin in order to produce morphological changes and reduce the acid reactivity of dentin without compromising the pulp vitality.
|
Page generated in 0.0497 seconds