• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 18
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 327
  • 168
  • 87
  • 83
  • 82
  • 66
  • 63
  • 58
  • 57
  • 41
  • 39
  • 33
  • 30
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação do comportamento da pressão arterial em pacientes transplantados renais através de três métodos de mensuração / Evaluation of the blood pressure im kidney transplantation using three methods of measurement

Fabiana Agena 17 January 2011 (has links)
A hipertensão arterial apresenta alta prevalência entre os receptores de transplante renal sendo considerada um fator de risco cardiovascular importante influenciando na sobrevida do paciente e do enxerto. O objetivo principal deste estudo foi comparar se o controle da pressão arterial nos pacientes transplantados renais por meio da utilização de monitorização residencial da pressão arterial é mais comparável ao resultado da monitorização ambulatorial da pressão arterial quando comparada à medida da pressão arterial de consultório. No período de março de 2008 a abril de 2009, foram avaliados prospectivamente 183 pacientes transplantados renais, com tempo de transplante de 1 a 10 anos. Os pacientes foram submetidos a três métodos de medida de pressão arterial (PA): medida de pressão arterial em consultório, monitorização residencial da pressão arterial (MRPA), e monitorização ambulatorial da pressão arterial (MAPA). Foram avaliados 183 pacientes, dentre eles 94 eram homens (54 %) e 89 mulheres (46 %). A idade média foi de 50 ± 11 anos. O tempo de transplante médio foi de 57 ± 32 meses. Noventa e nove pacientes receberam enxertos de doadores falecidos (54 %) e 84 foram receptores de doadores vivos (46 %). Quando avaliados usando a medida de PA obtida em consultório, 56,3% apresentavam-se PA elevada e 43,7% com PA normal com média de 138,9/82,3 ± 17,8/12,1mmHg. Entretanto, quando avaliados pela MRPA, 55,2% dos indivíduos apresentavam-se PA normal e 44,8 % apresentavam-se PA elevada com média de 131,1/78,5 ± 17,4/8,9. Utilizando a MAPA observamos que 63,9 % dos indivíduos apresentavam-se PA normal e 36,1 % dos indivíduos apresentavam-se PA elevada com média de 128,8/80,5 ± 12,5/8,1. Verifica-se que os dois métodos (Consultório e MRPA) tem concordância significativa com a MAPA, mas a MRPA tem uma concordância maior que a medida de Consultório, comprovado pelo teste Exato de Fisher, com valor descritivo de 0,026. Pelo teste de McNemar, verificamos que não há simetria nos dados nos dois métodos (MRPA e Consultório). Os índices de correlação linear de Pearson dos métodos, comparadas a MAPA, foram de 0,494 para medida de consultório e de 0,768 para MRPA, com a MRPA com melhor correlação com a MAPA. Comparando os erros dos dois métodos pelo teste t pareado, obteve-se o nível descritivo de 0,837, pelo qual concluí-se que o erro médio da PA de Consultório é igual ao do MRPA. Analisando a curva ROC para as medidas de PA em cada método, observa-se que a PA em consultório apresenta-se áreas sob a curva mais baixas que as obtidas pela MRPA em relação a MAPA. Concluí-se que os resultados pressóricos obtidos com a MRPA são mais comparáveis aos resultados obtidos pela MAPA em relação àqueles obtidos pela medida de consultório, sendo factível sua realização em um hospital publico / Hypertension is highly prevalent among kidney transplantation recipients and considered an important cardiovascular risk factor influencing patient survival and kidney graft survival. The aim of this study were to compare the blood pressure (BP) control in kidney transplant patients through the use of home blood pressure monitoring is more comparable with the results of ambulatory blood pressure monitoring compared to the measurement of office blood pressure. From March 2008 to April 2009 prospectively we were evaluated 183 kidney transplant recipients with time after transplantation 1 - 10 years. Patients underwent three methods for measuring blood pressure: office blood pressure measurement (OM), home blood pressure monitoring (HBPM) and ambulatory blood pressure monitoring (ABPM). We evaluated 183 patients, among them 94 men (54%) and 89 women (46%). The average age was 50 ± 11 years. The average time of transplant was 57 ± 32 months. Ninety-nine patients received grafts from deceased donors (54%) and 84 were recipients of living donors (46%). When assessed using OM, 56.3% presented with uncontrolled and 43.7% with adequate control of BP with an average of 138.9 / 82.3 ± 17.8 / 12.1 mmHg. However, when measured by HBPM, 55.2% of subjects were controlled and 44.8% presented with uncontrolled BP with an average of 131.1 / 78.5 ± 17.4 / 8.9 mmHg. Using the ABPM we observed that 63.9% of subjects had was controlled and 36.1% of patients presented uncontrolled BP with an average 128.8 / 80.5 ± 12.5 / 8.1.mmHg We found that the two methods (OM and HBPM) has a significant agreement, but the HBPM has a higher agreement than OM, confirmed by Fisher exact test, with descriptive value of 0.026.We found that there is no symmetry in the data for both methods with McNemar test. Person´s correlation for the ABPM with the other two methods were 0.494 for office measurement and 0.768 for HBPM, best value of HBPM with ABPM. Comparing the errors of the two methods by paired t-test, we obtained the descriptive level of 0.837, we conclude that the average error is equal to OM of HBPM. Looking at the ROC curve for BP measurements in each method, we observed that BP in practice presents lower than those obtained by HBPM in relation to ABPM. We conclude that the results obtained with HBPM were closer to the ABPM results than those obtained with blood pressure obtained at OM
112

Avaliação do comportamento da pressão arterial em pacientes transplantados renais através de três métodos de mensuração / Evaluation of the blood pressure im kidney transplantation using three methods of measurement

Agena, Fabiana 17 January 2011 (has links)
A hipertensão arterial apresenta alta prevalência entre os receptores de transplante renal sendo considerada um fator de risco cardiovascular importante influenciando na sobrevida do paciente e do enxerto. O objetivo principal deste estudo foi comparar se o controle da pressão arterial nos pacientes transplantados renais por meio da utilização de monitorização residencial da pressão arterial é mais comparável ao resultado da monitorização ambulatorial da pressão arterial quando comparada à medida da pressão arterial de consultório. No período de março de 2008 a abril de 2009, foram avaliados prospectivamente 183 pacientes transplantados renais, com tempo de transplante de 1 a 10 anos. Os pacientes foram submetidos a três métodos de medida de pressão arterial (PA): medida de pressão arterial em consultório, monitorização residencial da pressão arterial (MRPA), e monitorização ambulatorial da pressão arterial (MAPA). Foram avaliados 183 pacientes, dentre eles 94 eram homens (54 %) e 89 mulheres (46 %). A idade média foi de 50 ± 11 anos. O tempo de transplante médio foi de 57 ± 32 meses. Noventa e nove pacientes receberam enxertos de doadores falecidos (54 %) e 84 foram receptores de doadores vivos (46 %). Quando avaliados usando a medida de PA obtida em consultório, 56,3% apresentavam-se PA elevada e 43,7% com PA normal com média de 138,9/82,3 ± 17,8/12,1mmHg. Entretanto, quando avaliados pela MRPA, 55,2% dos indivíduos apresentavam-se PA normal e 44,8 % apresentavam-se PA elevada com média de 131,1/78,5 ± 17,4/8,9. Utilizando a MAPA observamos que 63,9 % dos indivíduos apresentavam-se PA normal e 36,1 % dos indivíduos apresentavam-se PA elevada com média de 128,8/80,5 ± 12,5/8,1. Verifica-se que os dois métodos (Consultório e MRPA) tem concordância significativa com a MAPA, mas a MRPA tem uma concordância maior que a medida de Consultório, comprovado pelo teste Exato de Fisher, com valor descritivo de 0,026. Pelo teste de McNemar, verificamos que não há simetria nos dados nos dois métodos (MRPA e Consultório). Os índices de correlação linear de Pearson dos métodos, comparadas a MAPA, foram de 0,494 para medida de consultório e de 0,768 para MRPA, com a MRPA com melhor correlação com a MAPA. Comparando os erros dos dois métodos pelo teste t pareado, obteve-se o nível descritivo de 0,837, pelo qual concluí-se que o erro médio da PA de Consultório é igual ao do MRPA. Analisando a curva ROC para as medidas de PA em cada método, observa-se que a PA em consultório apresenta-se áreas sob a curva mais baixas que as obtidas pela MRPA em relação a MAPA. Concluí-se que os resultados pressóricos obtidos com a MRPA são mais comparáveis aos resultados obtidos pela MAPA em relação àqueles obtidos pela medida de consultório, sendo factível sua realização em um hospital publico / Hypertension is highly prevalent among kidney transplantation recipients and considered an important cardiovascular risk factor influencing patient survival and kidney graft survival. The aim of this study were to compare the blood pressure (BP) control in kidney transplant patients through the use of home blood pressure monitoring is more comparable with the results of ambulatory blood pressure monitoring compared to the measurement of office blood pressure. From March 2008 to April 2009 prospectively we were evaluated 183 kidney transplant recipients with time after transplantation 1 - 10 years. Patients underwent three methods for measuring blood pressure: office blood pressure measurement (OM), home blood pressure monitoring (HBPM) and ambulatory blood pressure monitoring (ABPM). We evaluated 183 patients, among them 94 men (54%) and 89 women (46%). The average age was 50 ± 11 years. The average time of transplant was 57 ± 32 months. Ninety-nine patients received grafts from deceased donors (54%) and 84 were recipients of living donors (46%). When assessed using OM, 56.3% presented with uncontrolled and 43.7% with adequate control of BP with an average of 138.9 / 82.3 ± 17.8 / 12.1 mmHg. However, when measured by HBPM, 55.2% of subjects were controlled and 44.8% presented with uncontrolled BP with an average of 131.1 / 78.5 ± 17.4 / 8.9 mmHg. Using the ABPM we observed that 63.9% of subjects had was controlled and 36.1% of patients presented uncontrolled BP with an average 128.8 / 80.5 ± 12.5 / 8.1.mmHg We found that the two methods (OM and HBPM) has a significant agreement, but the HBPM has a higher agreement than OM, confirmed by Fisher exact test, with descriptive value of 0.026.We found that there is no symmetry in the data for both methods with McNemar test. Person´s correlation for the ABPM with the other two methods were 0.494 for office measurement and 0.768 for HBPM, best value of HBPM with ABPM. Comparing the errors of the two methods by paired t-test, we obtained the descriptive level of 0.837, we conclude that the average error is equal to OM of HBPM. Looking at the ROC curve for BP measurements in each method, we observed that BP in practice presents lower than those obtained by HBPM in relation to ABPM. We conclude that the results obtained with HBPM were closer to the ABPM results than those obtained with blood pressure obtained at OM
113

Avaliação técnica SPME/LC na análise de antidepressivos em amostra de plasma para fins de monitorização terapêutica / Evaluation of SPME/LC technique in the antidepressants analysis in plasma sample for ends of therapeutic monitoring

Silva, Bruno José Gonçalves da 20 April 2007 (has links)
As recentes técnicas miniaturizadas de preparo de amostra, microextração em fase sólida (SPME) e in tube SPME, apresentam uma série de vantagens em relação aos métodos clássicos de extração (extração líquido-líquido e extração em fase sólida), tais como: não requer instrumentação analítica sofisticada, utilização de pequenas quantidades de solventes orgânicos, rápido processo operacional, permite automação das análises, a reutilização das fases extratoras, e integra em um único sistema a extração, concentração e introdução da amostra no cromatográfico. Esta dissertação tem como objetivo a padronização, validação e comparação dos métodos SPME/LC-UV com dessorção off line e in tube SPME/LC-UV, para a análise dos antidepressivos da nova geração (mirtazapina, citalopram, paroxetina, duloxetina, fluoxetina e sertralina) em amostras de plasma para fins de monitorização terapêutica. As variáveis: fase extratora, pH da matriz, tempo e temperatura de extração e de dessorção e força iônica apresentaram grande influência na eficiência do processo SPME. O método SPME/LC-UV padronizado, apresentou limite de quantificação (LQ) de 25 a 50 ng mL-1, ampla faixa de linearidade (LQ ? 500 ng mL-1, r2 > 0,9970) e precisão inter ensaios com coeficientes de variação menor que 15% para todos os analitos. Apesar das baixas taxas de recuperação obtidas, de 8,1% (citalopram) a 17,1% (mirtazapina), o método SPME/LC-UV apresentou seletividade e sensibilidade analítica adequada. As variáveis: pH da matriz, fluxo e número de ciclos aspirar/dispensar e volume de amostra apresentaram grande influência na eficiência do processo in tube SPME. A etapa de precipitação de proteínas do plasma, anterior ao processo de extração, foi necessária para a eliminação dos compostos endógenos. O método in tube SPME/LC-UV padronizado apresentou seletividade adequada, precisão inter ensaios com coeficiente de variação menor que 10%, LQ de 20 a 50 ng mL-1, linearidade na faixa de concentração do LQ a 500 ng mL-1, com r2 > 0,9983 para todos os analitos e recuperação absoluta de 5,32% (mirtazapina) a 43,5% (sertralina). A técnica in tube SPME, quando comparada à SPME, permitiu a automação das análises, menor exposição do analista às amostras biológicas e solventes orgânicos, menor tempo de análise e menor volume de amostra de plasma. A eficácia dos métodos, SPME/LC-UV e in tube SPME/LC-UV, foi comprovada através das análises de amostras de plasma de pacientes em terapia com os antidepressivos, para fins de monitorização terapêutica. / The recent miniaturized sample techniques preparation, solid phase microextraction (SPME) and in tube SPME, present several advantages when compared with classic extraction methods (liquid-liquid extraction and solid phase extraction), such as: it does not require sophisticated analytical instrumentation, use small organic solvent amounts, fast operational process, automation of the analyses, reuse extraction phases, and incorporates, into a single procedure, sample extraction, concentration and sample introduction. The aim of this work is development, validation and comparison of methods SPME/LC-UV with off line desorption and in tube SPME/LC-UV, for analyses of antidepressants of the new generation (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) in plasma samples for therapeutic drug monitoring. Variables: extraction phase, matrix pH, time and temperature of extraction and desorption and ionic strength showed great influence in SPME process efficiency. The method SPME/LC-UV presented limit of quantification (LOQ) variety from 25 to 50 ng mL-1, wide range the of linearity (LOQ 500 ng mL-1, r2 > 0.9970) and interassays precision with coefficient of variation lower than 15% for all analytes. Although the low recovery, from 8.1% (citalopram) to 17.1% (mirtazapine), the method SPME/LC-UV presented adequate selectivity and analytical sensitivity. Variables: matrix pH, flow and number of aspirate/dispense cycles and sample volume showed great influence in the in tube SPME process efficiency. The protein precipitation of the plasma steps, previous to the extraction process, was necessary for the endogenous compounds elimination. The method in tube SPME/LC showed adequate selectivity, interassays precision with coefficient of variation lower than 10%, LOQ variety from 20 to 50 ng mL-1, linearity in range concentration from LOQ to 500 ng mL-1, with r2 > 0.9983 for all analytes and recovery from 5.32% (mirtazapine) to 43.5% (sertraline). The technique in tube SPME, compared with the SPME, permitted the automation of the analyses, minor exposition of the analyst to the biological samples and organic solvent, shorter analyses time and minor plasma sample volume. The effectiveness methods, SPME/LC-UV and in tube SPME/LC-UV, was proven through the analyses of plasma samples of patients in therapy with antidepressants, for therapeutic drug monitoring.
114

Estudo da gestação no período de 40 a 42 semanas: avaliação da vitalidade fetal e resultados neonatais / Study about pregnancy between 40 to 42 weeks: evaluation of the fetal well being and neonatal outcome

Lopes, Marco Antonio Borges 18 April 1996 (has links)
Neste trabalho foi proposto o estudo prospectivo de gestações após a 40a semana, objetivando: a) verificar os índices de morbidade e mortalidade perinatais; b) identificar os testes de avaliação da vitalidade fetal mais adequados para a vigilância destas gestações; c) comparar os resultados dos testes de avaliação da vitalidade fetal com os resultados perinatais na 1a e 2a semana, após a 40a semana de gestação, para testar o protocolo do Serviço. Para a realização do estudo, selecionaram-se 52, gestantes divididas em 2 grupos: GI (1a semana) com 32 gestantes e GIl (2a semana) com 20 gestantes. Acompanhou-se a vitalidade fetal com a Cardiotocografia de Repouso e Intraparto, Teste da Estimulação Sônica, Avaliação do Volume do Líquido Amniótico através da Técnica dos Quatro Quadrantes, Perfil Biofisico Fetal e Dopplerfluxometria Uterina e Umbilical, realizados 2 vezes na semana. Os resultados neonatais e os índices de morbidade foram: Índices de Apgar no 10 e 50 minutos (alterados < 7), pH da artéria umbilical (alterado < 7,20), peso dos recém-nascidos, tempo de internação dos recém-nascidos, oligoidrâmnia, líquido amniótico meconial, alterações na cardiotocografia com presença de desacelerações e índices de cesárea. O estudo permitiu como resultados e conclusões: a) a incidência de oligoidrâmnio foi de 44,23%, líquido meconial de 28,85%, cardiotocografia alterada, 50,00% e partos cesáreos, 57,70%, não havendo óbito fetal ou neonatal. Não houve alterações significativas nos índices de Apgar, pH da artéria umbilical e tempo de internação dos recém-nascidos. b) A cardiotocografia e, principalmente, a avaliação do volume do líquido amniótico, pelo índice de líquido amniótico, foram os métodos mais adequados na detecção de alterações verificadas neste grupo de gestantes. Do parâmetro ultra-sonográfico do Perfil Biofisico Fetal, apenas o Volume do Líquido Amniótico demonstrou ser importante. A Dopplerfluxometria (uterina e umbilical) não revelou nenhuma utilidade na vigilância destas gestações. c) A distribuição dos casos com oligoidramnia, líquido meconial, cardiotocografia alterada, índices de cesárea e pH da artéria umbilical < 7,20, semelhante na 41a semana (GI) e 42a semana (GIl), valida o protocolo do Serviço. d) Adicionalmente, este estudo permite ainda as seguintes observações: 1) importância da oligoidrâmnia e líquido meconial na determinação dos elevados índices de cesáreas; 2) incidência elevada (50,00) de nulíparas nesta casuística. / This study proposed pros.pectively the evaluation of the gestations after 40 weeks with these objectives: a) Analysis of the perinatal outcome. b) Identification of the proper test for fetal well-being assessment for this gestation. c) Comparation of these tests results with perinatal outcome at the first and second weeks after 40 weeks, therefore, testing the protocol of this Service. It recruited 52 patients divided in two groups: GI (1st week) with 32 patients and Gil (2nd week) with 20 patients. The fetal surveillance was assessed by antepartum and intrapartum cardiotocography, acoustic stimulation test, amniotic fluid volume assessment by the ultrasonographic four quadrant technique (amniotic fluid index), fetal biophysical profile and umbilical and uterine doppler velocimetry, ali tests were performed twice weekly. The neonatal outcome results and morbidity parameters were: Apgar index in 1st and s\" minutes (alterated < 7), umbilical artery pH (alterated < 7,20), the new born weight, oligohydramnios, meconium stained, deceleration (DIP 11 or umbilical deceleration) and cesarean section rates. The study permitted these results and conclusions: a) The oligohydramnios, meconium stained, cardiotocography alterations and cesarean section incidences were 44,23%, 28,85%, 50,00% and 57,70%, respectively. There was no fetal death. b) The cardiotocography and amniotic fluid assessment by the amniotic fluid index, were the best tests to detect the alterations verified. The amniotic fluid volume was the most important parameter in the fetal biophysical profile. Doppler (uterine and umbilical) revealed no utility. c) The equal distribution of the oligohydramnios, meconium stained, altereted cardiotocography, cesarean section and umbilical artery pH < 7,20 cases in the group studied reassure the Service protocol. d) In addition this study also permitted observation of: 1) The importance of the meconium stained in the cesarean section rate. 2) The nuliparus elevated incidence (50,00%) in this group.
115

Epilepsia Refratária e Lamotrigina: Monitorização terapêutica e resposta clínica em pacientes ambulatoriais / Refractory Epilepsy and Lamotrigine: Therapeutic Drug Monitoring and Clinical results in outpatients

Baldoni, André de Oliveira 27 September 2013 (has links)
Introdução: O tratamento farmacológico é primeira opção para o tratamento da epilepsia, e cerca de 40% dos pacientes não respondem à monoterapia e, sendo necessário o uso de dois ou mais fármacos antiepilépticos (FAE) para o melhor controle das crises epilépticas. Nesta situação clínica a lamotrigina (LTG) é o FAE de segunda geração com maior prevalência de uso, em associação com os demais FAE. Objetivo: Analisar o perfil sociodemográfico, farmacoepidemiológico, clínico e laboratorial dos pacientes com epilepsia refratária em uso de LTG, bem como verificar a racionalidade da monitorização terapêutica da LTG. Casuística e Método: Este estudo de caráter observacional e transversal foi realizado com 75 pacientes com epilepsia refratária em uso de LTG atendidos no Ambulatório de Epilepsia de Difícil Controle (AEDC) do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (HCFMRP-USP), no período de maio/2011 a abril/2012. As variáveis clínicas analisadas foram a qualidade de vida (Quality of Life in Epilepsy - Qolie-31), o perfil de eventos adversos (AEP - Adverse Events Profile) e a adesão ao tratamento medicamentoso (Morisky- Green). Os dados sociodemográficos e farmacoterapêuticos foram coletados através dos prontuários médicos. Além disso, foi realizada a dosagem da concentração plasmática da LTG e dos FAE de primeira geração. Para testar as hipóteses o nível de significância foi fixado em ? = 0,05, e intervalo de confiança de 95%. O trabalho foi aprovado pelo Comitê de Ética em Pesquisa do HCFMRP (no 8791/2010). Resultados e Discussão: Identificou-se elevada prevalência de uso de politerapia (97%), 29% dos pacientes apresentaram concentrações plasmáticas de LTG abaixo do intervalo de referência preconizado (< 2,5 mg/L), 45% utilizaram doses mg/kg/dia abaixo do recomendado, e 60% apresentaram comprometimento com a adesão ao tratamento medicamentoso. Os FAE de primeira geração influenciaram de forma significativa a concentração plasmática de LTG (p< 0,01). A concentração plasmática de LTG apresentou associação com a dose (mg/kg/dia) utilizada pelos pacientes (p = 0,0096). Os eventos adversos mais prevalentes foram sonolência e dificuldade de concentração. Baixos escores foram observados em todos os domínios relacionados à qualidade de vida (Qolie-31), sugerindo comprometimento significativo desse parâmetro humanístico entre os pacientes com epilepsia refratária. A qualidade de vida apresentou associação inversamente significativa com os eventos adversos obtidos pelo AEP (r = -0.69, p<0.01). Conclusão: Os pacientes com epilepsia refratária em uso de LTG apresentaram elevada prevalência de problemas clínicos, humanísticos e farmacoterapêuticos, o que demonstra a necessidade de implementação de estratégias para otimização do tratamento farmacológico, tais como, implementação efetiva e permanente da monitorização terapêutica de LTG nos serviços de saúde. / Introduction: The pharmacological treatment is the first choice for the treatment of epilepsy and about 40% of patients are not responding to monotherapy. Therefore these require two or more antiepileptic drugs (AED) for better control of seizures. In this clinical situation, lamotrigine (LTG) is the AED of second generation most used in combination with other AED. Objective: To analyze the demographic, pharmacoepidemiological, clinical and laboratorial profile of patients with refractory epilepsy using LTG, as well as, to analyze the rationality of LTG therapeutic monitoring. Casuist and Methods: This observational and cross-sectional study was conducted on 75 adult outpatients with refractory epilepsy in use of LTG attended at the Ambulatory of epilepsy difficult to control (AEDC) of the Ribeirão Preto Medical School University Hospital (HCFMRP-USP). The patients were invited between May 2011 to April 2012. The clinical variables analyzed by questionnaire were quality of life (Quality of Life in Epilepsy - QOLIE-31), adverse event profile (AEP - Adverse Events Profile) and medication adherence (Morisky-Green). The sociodemographic and pharmacotherapeutic variables were collected through medical records. In addition, it was performed plasma concentration of LTG and of the first generation AED. To test the hypotheses the significance level was set at ? = 0.05, and a confidence interval of 95%. The study was approved by the Research Ethics Committee of HCFMRP-USP. Results and Discussion: It was observed high prevalence of use of polytherapy (97%), 29% of patients had LTG plasma concentrations below the recommended reference range (<2.5 mg / L), 45% used doses mg/kg/day lower than recommended, and 60% were not adherent to medication. The first generation AED influenced significantly in the LTG plasma concentration (p <0.01). The LTG dose (mg/kg/day) used by patients presented positive association with LTG plasma concentration (p = 0.0096). The most prevalent adverse events were somnolence and difficulty concentrating. Low scores were observed in all subscales related to quality of life (QOLIE-31), suggesting significant harm of this humanistic parameter among patients with refractory epilepsy. The quality of life was associated inversely with adverse events obtained by AEP (r = - 0.69, p <0:01). Conclusion: Patients with refractory epilepsy using LTG had high prevalence of clinical, humanistic and pharmacotherapeutic problems, which demonstrates the need to implement strategies for optimization of pharmacological treatment, such as, implementation of permanent and effective therapeutic monitoring of LTG in health services.
116

Monitorização terapêutica do topiramato em pacientes com epilepsia refratária / Therapeutic Drug Monitoring of topiramate in patients with refractory epilepsy

Fabiana Angelo Marques 06 April 2015 (has links)
A estratégia mais amplamente utilizada no tratamento da epilepsia é a farmacoterapia. Entretanto cerca de 30% dos pacientes mesmo utilizando o fármaco adequado para o seu diagnóstico não respondem ao tratamento proposto, sendo então diagnosticados com epilepsia refratária. Entre as drogas antiepilépticas (DAE) utilizadas no tratamento da epilepsia refratária encontra-se o topiramato (TPM). O objetivo do presente estudo foi avaliar a concentração plasmática (Cp) do TPM verificando a influência da dose prescrita (mg/Kg/dia), sexo, idade e o uso de outras DAE sobre a mesma, correlacionando-a com a frequência de crises epilépticas, reações adversas, qualidade de vida e adesão a farmacoterapia. Este estudo observacional transversal foi realizado com 37 pacientes com epilepsia refratária em uso de TPM atendidos no Ambulatório de Epilepsia de Difícil Controle do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo. As variáveis de interesse foram qualidade de vida (Quality of Life in Epilepsy - QOLIE-31), reações adversas ao medicamento (RAM) (Liverpool Adverse Event Profile - LAEP), adesão a farmacoterapia (Modified Morisky Scale - MMS), tipo de crise epiléptica, tipo de epilepsia, frequência das crises, características farmacoterapêuticas e sociodemográficas, obtidas por meio de instrumentos na entrevista com o paciente ou em prontuário. Além disso, amostras de sangue de todos os participantes foram coletadas para dosagem da Cp de TPM, lamotrigina e DAEs de primeira geração em uso. O trabalho foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Ciências Farmacêuticas de Ribeirão Preto-USP (nº 030/2014). A idade média dos pacientes foi 40 anos (DP 10,7) e apresentavam prevalentemente epilepsia focal sintomática (73,0%) e crises parciais complexas (67,6%). Em relação ao perfil farmacoterapêutico, 97,3% dos pacientes estavam em politerapia, sendo o esquema farmacoterapêutico mais prevalente a associação entre TPM, carbamazepina e clobazam (29,8%). A Cp de 83,8% dos pacientes em uso de TPM encontraram-se abaixo do intervalo de referência recomendado (5,0 -20,0 mg/L), sendo a Cp média de 3,21 mg/L (DP 2,76). A dose prescrita (mg/Kg/dia) e o uso concomitante de indutores do metabolismo do TPM explicaram 69,0% da variabilidade da Cp do TPM: estimou-se que o aumento na dose de 1,0 mg/Kg/dia tenha promovido o aumento de 0,68 mg/L na Cp do TPM, enquanto o uso de indutores esteve relacionado a uma redução de 2,97 mg/L (p?0,001). Os pacientes com Cp < 5,0 mg/L apresentaram o número médio de crises epilépticas maior do que aqueles com Cp no intervalo de referência (p<0,001). A pontuação média do LAEP foi de 40,5 (DP 10,1) e a sonolência, problemas de memória e o nervosismo e/ou agressividade foram as reações adversas mais prevalentes. Com relação à qualidade de vida o escore médio obtido no QOLIE-31 foi de 47,7 (DP 15,2), sendo que a preocupação com as crises e a função social foram os domínios que apresentaram maior comprometimento na qualidade de vida dos pacientes. Ademais, foram encontradas evidências de uma relação inversa entre RAM e a qualidade de vida, sendo que o aumento de um ponto no escore do LAEP reduz o escore do QOLIE-31 em 0,91 pontos. Finalmente, segundo resultados do MMS, 62,2% dos pacientes eram aderentes ao tratamento medicamentoso. Em conclusão a dose prescrita e o uso de DAE indutoras do metabolismo do TPM influenciaram a Cp deste fármaco, a qual afetou o controle das crises epilépticas. Diante disto sugere-se a monitorização terapêutica como uma ferramenta para a otimização da farmacoterapia e da resposta clínica. / The most widely used strategy in epilepsy treatment is pharmacotherapy. However, near 30% of all patients, even though receiving the appropriate drug, do not respond to recommended treatment. Among the antiepileptic drugs (AED) used for the treatment of refractory epilepsy there is topiramate (TPM). The aim of this study was to evaluate TPM\'s plasma concentration (Cp) and to verify the influence of some variables [prescribed dose (mg/Kg/day), sex, age and other AED in use] on it, as well as correlate TPM\'s Cp with the frequency of epileptic crises, adverse events, quality of life and adherence to pharmacotherapy. This cross-sectional study enrolled 37 patients diagnosed with refractory epilepsy in use of TPM attended at the Epilepsy of Difficult Control\'s ambulatory of the Ribeirão Preto Medical School University Hospital. The investigated variables were quality of life (Quality of Life in Epilepsy - QOLIE-31), adverse drug reactions (ADR) (Liverpool Adverse Event Profile - LAEP), adherence to pharmacotherapy (Modified Morisky Scale - MMS), type of epileptic crisis, type of epilepsy, frequency of crises, pharmacotherapeutic and sociodemographic characteristics, all of them obtained through medical records and/or face to face interview. Moreover, blood samples of all patients were collected in order to measure Cp of TPM, lamotrigine and first generation AEDs in use. The study was approved by the Research Ethics Committee of the School of Pharmaceutical Sciences of Ribeirão Preto-USP (nº 030/2014). The patients\' mean age was 40 years (SD 10.7) and they showed predominantly symptomatic focal epilepsy (73.0%) and partial complex seizures (67.6%). Considering the pharmacotherapeutic profile, 97.3% of them were under polytherapy, in which the most prevalent regimen consisted in the combination of TPM, carbamazepine and clobazam (29.8%). From all patients in use of TPM, the mean Cp for this drug was 3.21 mg/L (SD 2.76) and 83.8% presented values below the recommended reference range (5.0 mg/L). The prescribed dose (mg/Kg/day) and concomitant use of TPM\'s metabolism inducers explained 69.0% of TPM\'s Cp variability: it was estimated that an increment of 1.0 mg/Kg/day in the dosage of TPM has lead to an increase of 0.68 mg/L in its Cp, while the use of inducers was related to a decrease of 2.97 mg/L (p?0.001). Patients with Cp < 5.0 mg/L showed a larger mean number of crises than those whose Cp was within the reference range (p<0.001). The LAEP\'s mean score was 40.5 (SD 10.1) and somnolence, memory problems and nervousness and/or agitation were the most common adverse events. Regarding quality of life, QOLIE-31\'s mean score was 47.7 (SD 15.2), wherein concern about the crisis and social role were the areas related to greater impairment in patients\' quality of life. Furthermore, we found evidences of an inverse relationship between ADR and quality of life in which the one point increase in LAEP score reduced QOLIE-31 score in 0.91 point. Finally, according to MMS results, 62.2% of patients were adherent to their treatment. In conclusion prescribed dose and concomitant use of AEDs that induced TPM\'s metabolism influenced on this drug\'s Cp, which seemed to affect epileptic seizures control. Thus, we suggest the use of therapeutic drug monitoring of TPM as a tool for pharmacotherapy optimization so as to improve the clinical response in these patients.
117

Reprocessamento e reutilização de cânulas de perfusão / Reprocessing and reuse of perfusion cannulas

Alzira Maria da Silva Martins 12 September 2005 (has links)
Os procedimentos utilizados para reprocessamento e reuso de artigos médicos de uso único não estão normalizados nem avaliados quanto a segurança. Os objetivos deste estudo foram: (i) determinar o tempo de esterilização e aeração de cânulas de perfusão em ambiente industrial; (ii) avaliar os níveis de resíduos de óxido de etileno, concentração de endotoxinas e resistência a tração de cânulas de perfusão após reprocessamento e reuso em ambiente hospitalar. No ambiente industrial as cânulas foram submetidas á esterilização com 450mg/L de 10% de óxido de etileno e 90% de CO2 por um período de 2 horas a uma temperatura de 45 a 55° C, umidade entre 30 e 90% aeração com 26 trocas de ar por hora com temperatura de 35°C. No ambiente hospitalar a cânula aramada TF 36460 foi utilizada em procedimento cirúrgico com circulação extracorpórea; lavada com água potável, desinfecção com detergente enzimático, enxague com água potável, embalada em papel grau cirúrgico e reprocessada por óxido de etileno com concentração de 500mg/L de 12% de óxido de etileno e 88% de Freon com tempo de exposição de 240 minutos, temperatura de 53°C, umidade entre 40-60% e aeração em temperatura ambiente. No ambiente industrial o tempo necessário para redução de 12 ciclos logarítmicos (SAL 10-6), foi de 120 minutos, no ambiente hospitalar foi de 240 minutos. O tempo de aeração variou de 19 a 28 horas na área industrial; e no ambiente hospitalar foi de 28 horas. No segundo reuso a cânula apresentou residual de óxido de etileno de 83,09 ppm; acima do limite especificado (&#8804;_25ppm). Os testes de resistência a tração e determinação da concentração de endotoxinas foram realizados até o quarto reuso não apresentando resultados fora dos limites especificados. O procedimento de reuso nas condições atuais realizado em ambiente hospitalar foi reprovado, pois não atendeu aos requisitos de residual de óxido de etileno descritos na portaria Brasileira Interministerial n&#176; 482. / The procedures used during reprocessing of disposables have not been normalized, nor assessed for safety. The objective of this study is to assess sterility, residual rate of ethylene oxide, pyrogenicity and resistance to traction results observed in perfusion cannulas after the sterilization process in industrial environments and after reprocessing and reuse in the hospital environment. In the industrial environment, the cannulas were submitted to sterilization with 450mg/L of EtO and 90% of CO2 during a period of 2 hours and at a temperature of 45-55°C, humidity ranging from 30 to 90% and aeration of 26 air changes per hour at a temperature of 35°C. For the hospital environment, we selected the TF 36460 wired cannula, and after using it on a surgical procedure with extracorporeal circulation, it was washed with clean water, disinfected with enzymatic detergent, rinsed with clean water, wrapped in surgical paper and reprocessed in 500mg/L ethylene oxide of 12% EtO and 88% Freon and exposed for 240 minutes at a temperature of 53°C, humidity ranging from 40 to 60% and aeration at room temperature. In the industrial environment, the time needed for decreasing 12 logarithm cycles (10-6) was 120 minutes, while in the hospital environment it was 240 minutes. The aeration time ranged between 19 and 28 hours in the industrial area, while in the hospital environment it took 28 hours. In the second reuse the cannula presented residual of ethylene oxide of 83,09 ppm; above of the specified limit (&#8804;25_ppm). The physical test and endotoxins concentration had been carried through until for reuse not presented results out of specified. The currently procedure of reuse in the hospital is disapproved therefore does not take care of the limits of ethylene oxide residues, recommended by Interministerial Brazilian regulation 482.
118

Reprocessamento e reutilização de cânulas de perfusão / Reprocessing and reuse of perfusion cannulas

Martins, Alzira Maria da Silva 12 September 2005 (has links)
Os procedimentos utilizados para reprocessamento e reuso de artigos médicos de uso único não estão normalizados nem avaliados quanto a segurança. Os objetivos deste estudo foram: (i) determinar o tempo de esterilização e aeração de cânulas de perfusão em ambiente industrial; (ii) avaliar os níveis de resíduos de óxido de etileno, concentração de endotoxinas e resistência a tração de cânulas de perfusão após reprocessamento e reuso em ambiente hospitalar. No ambiente industrial as cânulas foram submetidas á esterilização com 450mg/L de 10% de óxido de etileno e 90% de CO2 por um período de 2 horas a uma temperatura de 45 a 55° C, umidade entre 30 e 90% aeração com 26 trocas de ar por hora com temperatura de 35°C. No ambiente hospitalar a cânula aramada TF 36460 foi utilizada em procedimento cirúrgico com circulação extracorpórea; lavada com água potável, desinfecção com detergente enzimático, enxague com água potável, embalada em papel grau cirúrgico e reprocessada por óxido de etileno com concentração de 500mg/L de 12% de óxido de etileno e 88% de Freon com tempo de exposição de 240 minutos, temperatura de 53°C, umidade entre 40-60% e aeração em temperatura ambiente. No ambiente industrial o tempo necessário para redução de 12 ciclos logarítmicos (SAL 10-6), foi de 120 minutos, no ambiente hospitalar foi de 240 minutos. O tempo de aeração variou de 19 a 28 horas na área industrial; e no ambiente hospitalar foi de 28 horas. No segundo reuso a cânula apresentou residual de óxido de etileno de 83,09 ppm; acima do limite especificado (&#8804;_25ppm). Os testes de resistência a tração e determinação da concentração de endotoxinas foram realizados até o quarto reuso não apresentando resultados fora dos limites especificados. O procedimento de reuso nas condições atuais realizado em ambiente hospitalar foi reprovado, pois não atendeu aos requisitos de residual de óxido de etileno descritos na portaria Brasileira Interministerial n&#176; 482. / The procedures used during reprocessing of disposables have not been normalized, nor assessed for safety. The objective of this study is to assess sterility, residual rate of ethylene oxide, pyrogenicity and resistance to traction results observed in perfusion cannulas after the sterilization process in industrial environments and after reprocessing and reuse in the hospital environment. In the industrial environment, the cannulas were submitted to sterilization with 450mg/L of EtO and 90% of CO2 during a period of 2 hours and at a temperature of 45-55°C, humidity ranging from 30 to 90% and aeration of 26 air changes per hour at a temperature of 35°C. For the hospital environment, we selected the TF 36460 wired cannula, and after using it on a surgical procedure with extracorporeal circulation, it was washed with clean water, disinfected with enzymatic detergent, rinsed with clean water, wrapped in surgical paper and reprocessed in 500mg/L ethylene oxide of 12% EtO and 88% Freon and exposed for 240 minutes at a temperature of 53°C, humidity ranging from 40 to 60% and aeration at room temperature. In the industrial environment, the time needed for decreasing 12 logarithm cycles (10-6) was 120 minutes, while in the hospital environment it was 240 minutes. The aeration time ranged between 19 and 28 hours in the industrial area, while in the hospital environment it took 28 hours. In the second reuse the cannula presented residual of ethylene oxide of 83,09 ppm; above of the specified limit (&#8804;25_ppm). The physical test and endotoxins concentration had been carried through until for reuse not presented results out of specified. The currently procedure of reuse in the hospital is disapproved therefore does not take care of the limits of ethylene oxide residues, recommended by Interministerial Brazilian regulation 482.
119

"Cardiotocografia estimulada em gestações de baixo risco: estudo comparativo da resposta cardíaca fetal à estimulação vibratória e sônica" / Stimulated cardiotocography in low-risk pregnancies: comparative study of fetal cardiac response to vibratory and sonic stimulation

Souza, Adriana Cristina de 07 June 2006 (has links)
Trata-se de estudo prospectivo, comparativo da resposta da freqüência cardíaca fetal (FCF) à estimulação vibratória e sônica, quanto à amplitude e duração, em 113 fetos de gestações de baixo risco. A população estudada foi discriminada em quatro grupos: 1) 25 semanas a 28 semanas e seis dias; 2) 29 semanas a 32 semanas e seis dias; 3) 33 semanas a 36 semanas e seis dias e 4) 37 a 42 semanas. Comparando-se a amplitude e a duração da resposta da FCF na faixa três e na faixa quatro, a resposta à estimulação vibratória foi menor que a sônica. Nas faixas um e dois não houve diferença nas respostas. Conclui-se que a estimulação vibratória promove resposta fetal (FCF) menos intensa com amplitude e duração de resposta menor quando comparada à estimulação sônica em faixa de idade gestacional mais tardia / This prospective study compares the response in terms of fetal heart rate acceleration after vibratory and sonic stimulation, in a sample of 113 fetuses of low-risk pregnancies. The study population was divided into four groups according to gestational age: group 1 - 25 weeks to 28 weeks and 6 days; group 2 - 29 weeks to 32 weeks and 6 days; group 3 - 33 weeks to 36 weeks and 6 days, and group 4 - 37 to 42 weeks. Comparing the amplitude and duration of the cardioacceleratory response between group 3 and 4, the response after vibratory stimulation was lower than sonic. In the groups 1 and 2, the response was similar. The study concludes that vibratory stimulation promotes a less intense response with amplitude and duration lower than sonic stimulation in latter gestational age
120

Aplicacao do oximetro de pulso em recem-nascidos internados na unidade de terapia intensiva, no bercario e durante atendimento na sala de parto

Felix, Elaine Aparecida January 1994 (has links)
O oxímetro de pulso tornou-se o método de escolha para monitorização não invasiva da oxigenação em recém-nascidos (RN). Em geral, as publicações são favoráveis quanto à obtenção da saturação de oxigênio através das leituras do oxímetro (Sp02) dando ênfase às facilidades de aplicação do sensor, à baixa freqüência de complicações, respostas rápidas e contínuas da Sp02 frente a mudanças na oxigenação sangüínea; e ainda à boa correlação da Sp02 com medidas invasivas da saturação de oxigênio no sangue arterial (Sa02). No entanto, a aplicabilidade do oxímetro de pulso em neonatos tem sido melhor documentada em unidades de terapia intensiva sendo escassos os trabalhos realizados em RN sadios, imediatamente após o parto. Este trabalho focaliza três aspectos da aplicação do oxímetro de pulso em neonatos: inicialmente compara os valores da saturação de oxigênio calculada (Sa02cal) na análise de gases sangüíneos com medidas da Sp02 em 32 RN doentes; numa segunda etapa busca relacionar os valores de Sp02 ao processo de adaptação normal à vida extra-uterina em 45 RN dentro dos primeiros dez minutos após o parto e no berçário, em 57 recém-nascidos nas primeiras duas horas de vida. Finalmente, identifica os problemas técnicos e Limitações no uso clinico do oxímetro de pulso capazes de influenciar a interpretação dos resultados. A análise comparativa de 45 pares de medidas simultâneas de Sp02 e Sa02cal obtidas dos 32 RN internados na unidade de cuidados intensivos mostrou uma correlação de O, 77 (Sp02 = 62,5 + 0,36 Sa02cal) enquanto a média das diferenças entre os valores absolutos da Sp02 e Sa02cal (bias) encontrada foi de 3,5% e a precisão de 5,6%. As diferenças entre as medidas foram menores em níveis de saturação de oxigênio acima de 85%. Abaixo destes, as Sp02 superestimaram os valores da Sa02cal. Os registros contínuos das medidas da Sp02 obtidos na sala de parto demonstraram que os valores médios da Sp02 foram sempre mais baixos para os neonatos avaliados nos primeiros dez minutos de vida (< 90%). Logo após, no berçário, foi verificado um aumento progressivo dos valores de Sp02 que rapidamente atingiram níveis ao redor de 92,7% em menos de 30 minutos, 95,5% em cerca de 60 minutos, alcançando subseqüentemente o patamar de 97,2 %. Foi adotado um critério padrão para a seleção de medidas contínuas da Sp02 isentas de dados espúrios. A extrema sensibilidade do sensor do oxímetro ao movimento e a outros fatores de interferências invalidou a maioria dos registros em neonatos nos primeiros 5 minutos após o parto. Estes problemas foram de relevância menor no ambiente menos conturbado do berçário. Neste estudo, o oxímetro de pulso mostrou-se útil para detectar os graus de variação da saturação de 02 no sangue arterial, característicos do período neonatal. Em adição, permitiu medir a velocidade em que o nível normal é alcançado após o parto. No contexto geral, o estudo demonstrou as falhas inerentes ao emprego da técnica. O equipamento não parece ser confiável em níveis de Sa02cal baixos e a interposição de fatores que interferem com a captação do sinal - se não forem excluídos das análises - fornecem resultados inacurados. Estas limitações exigem cautela na interpretação dos dados de monitorização da oxigenação do neonato. / Pulse oximetry has become the method of choice for non-invasive monitoring of oxygenation in newbo rn infants. In general, the reports have been favourable regarding neonatal oxygen saturation from the oximeter readings (Sp02) with emphasis on the easy application of Sp02 probes, infrequency of cutaneous injury, rapiel and continuous response of Sp02 to changes in blooel oxygenation, anel gooel correlation of Sp02 with invasive oxygen saturations (Sa02). So far, the applicability of pulse oximetry in neonates has been mainly elocumenteel in intensive care units anel less in healthy infants, immediately after delivery. This work focuses on three aspects of pulse oximetry application in neonates: 1- in the comparison of calculateel oxygen saturation values (Sa02cal) with Sp02 in 32 critically ill infants; 2- in following the normal aelaptation to extrauterine life within 10 minutes of ele livery (n=45) anel then through the first two hours (n=57); 3- in the ielentification of the technical problems encountereel eluring its routine clinicai use anel the pitfalls in the interpretation of results. The comparative analysis of 45 pairs of simultaneously measureel Sp02 anel Sa02cal obtaineel from 32 infants in the intensive care unit showeel a correlation of 0,77 (Sp02 = 62,5 + 0,36 Sa02cal) while the mean of the absolute differences between Sp02 and Sa02cal values (bi::~s) was founel to be 3,5% anel precision of 5,6%. The elifferences betwen measurements were small er at saturations above 85%. Sp02 overestimateel Sa02cal when the values of Sa02cal were at lower leveis. The continuous recoreling of the Sp02 taken in the elelivery room demonstrateel that the mean values of Sp02 were alwalys lower for neonates in their first 10 minutes of life (below 90%). Shortly thereafter at the nursery a progressive elevation of Sp02 was rapidly accomplisheel with mean values arou nel 92,7% in less than 30 minutes, 95,5% within 60 minutes reaching subsequently a plateau of 97,2 %. Criteria for measu ring continuously the Sp02 output from the oximeter were stanelarelizeel in oreler to obtain artifact free data. The extreme sensitivity of the oximeter probe to movement anel other interference facto rs invalielateel most of the records from newborns five minutes after elelivery. These problems were consiclerably less relevant in the unelisturbeel environment of the nursery. In this s tucly, the pulse oximeter provecl useful to detect the degree of oxygen saturation of arteri al blood which characterizes the neonatal period, anel to measure the speed with which the normal levei is attained after de livery. The overall s tudy has also shown the drawbacks of the technique. The equipment seems not to be reliable at JQ\.ver Sa02cal values anel the interposition of interfering factors disturbing signal captation, if not exclucled from the analysis, give inaccurate results. These limitations encountered here in are meaningful in monitoring oxygenation o f neonates anel cal I for caution in the interpretation of data.

Page generated in 0.0497 seconds