• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • Tagged with
  • 109
  • 60
  • 58
  • 33
  • 21
  • 20
  • 19
  • 19
  • 17
  • 17
  • 15
  • 14
  • 14
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Estudo da função da tuba de eustáquio em pacientes com retrações da membrana timpânica e em indivíduos normais / Assessment of eustachian tube function in patients with tympanic membrane retraction and in normal subjects

Canali, Inesângela January 2013 (has links)
Introdução: O diagnóstico das disfunções da tuba auditiva é essencial para o melhor entendimento da patogênese da otite média crônica. Estão descritos, na literatura, uma série de testes que avaliam a função tubária, entretanto, entre eles, há uma diversidade metodológica que varia desde os protocolos de aplicação até a padronização dos testes e seus resultados. Objetivo: Avaliar a variação da pressão na orelha média em pacientes com retração da membrana timpânica e em indivíduos normais, durante a realização dos testes de função tubária, bem como avaliar a variação intraindividual desses testes. Este estudo também tem por objetivo avaliar o número de movimentações da membrana timpânica na orelha contralateral, durante a realização dos testes. Métodos: Estudo observacional do tipo transversal e contemporâneo, onde o fator em estudo foi a variação de pressão na orelha média, durante a realização dos testes de função tubária (Manobra de Valsalva, Sniff Test, Manobra de Toynbee) em indivíduos normais e em pacientes com retrações timpânicas leves e moderadas/severas. Foram incluídos 38 pacientes, totalizando 76 orelhas. Os pacientes foram submetidos, em dois momentos diferentes, aos testes de função tubária para determinar a medida da pressão após cada manobra. Durante a realização dos testes, videotoscopia era realizada concomitantemente na outra orelha, a fim de se observar a movimentação da membrana timpânica. A análise estatística foi realizada por meio do programa SPSS versão 18.0, em que foram considerados como estatisticamente significativos os valores de p< 0,05. Resultados: A média ± desvio-padrão da idade foi de 11 ± 2,72 anos; 55,3% dos pacientes foram do sexo masculino e 44,7% do sexo feminino. A prevalência de curva A foi maior nos grupos de orelhas normais e retrações leves, enquanto que de curva C foi maior no grupo de retrações moderadas/severas. Observamos aumento das pressões na orelha média durante a realização da Manobra de Valsalva no primeiro momento de avaliação nos três grupos de orelhas (p= 0,012). A variação da pressão não foi significativa nem para o Sniff Test, nem para o Toynbee nos dois momentos de avaliação (p≥0,05). A concordância das medidas nos dois diferentes momentos foi de fraca a moderada para os testes nos três grupos de orelhas, e as variâncias da discrepância entre as medidas foram maiores nas orelhas com retrações moderadas/severas. Apesar de não ter atingido significância estatística, o número de movimentações da membrana timpânica foi maior durante a manobra de Valsalva nos três grupos de orelhas. Conclusão: Na população estudada, a média das pressões na cavidade timpânica apresentou uma variação significativa somente durante a Manobra de Valsalva, no primeiro momento de avaliação, nos três grupos de orelhas. As orelhas normais e as com retração leve se comportaram de forma semelhante entre si em todos os testes. As manobras utilizadas apresentaram uma variação intraindividual de fraca a moderada, sendo que maior variação ocorreu em orelhas com retrações moderadas/severas. O número de movimentações da membrana timpânica foi maior durante a manobra de Valsalva nos três grupos de orelhas. / Introduction: The diagnosis of Eustachian tube dysfunctions is essential for better understanding the pathogenesis of chronic otitis media. The literature describes a series of tests to assess tube function; however, there is methodological diversity between them, which varies from application protocols to standardization of tests and their results. Objective: To evaluate the variation in middle ear pressure in patients with tympanic membrane retraction and in normal subjects during tube function tests, as well as to evaluate intra-individual variation between these tests. This study also aimed to evaluate the number of tympanic membrane movements of the contralateral ear during the tests. Methods: An observational contemporary cross-sectional study was conducted, in which the factor under study was the variation in middle ear pressure during tube function tests (Valsalva maneuver, Sniff Test, Toynbee maneuver) in normal subjects and in patients with mild and moderate/severe tympanic retraction. A total of 38 patients (76 ears) were included in the study. Patients underwent tube function tests at two different time points, in order to determine the measure of pressure after each maneuver. During the tests, videotoscopy was performed concomitantly in the contralateral ear, in order to observe tympanic membrane movement. Statistical analysis was performed using SPSS software, version 18.0, considering p values < 0.05 as statistically significant. Results: Mean ± standard deviation for age was 11 ± 2.72 years; 55.3% of patients were male and 44.7% female. The prevalence of type A tympanogram was higher in the groups with normal ears and mild retraction, while type C tympanogram was higher in the group with moderate/severe retraction. An increase in middle ear pressure was observed during Valsalva maneuver at the first time point evaluated in the three groups of ears (p= 0.012). The variation in pressure was not significant either for the Sniff Test or for Toynbee maneuver at the two time points evaluated (p≥0.05). The agreement of the measures at the two different time points was from weak to moderate for the tests in the tree groups of ears, and the variations in discrepancy between measures were higher in ears with moderate/severe retraction. Although it had not reached statistical significance, the number of tympanic membrane movements was higher during the Valsalva maneuver in the tree groups of ears. Conclusion: In this study population, mean pressure in the middle ear showed a significant variation only during the Valsalva maneuver at the first time point evaluated in the three groups of ears. Normal ears and those with mild retraction behaved similarly in all tests. The maneuvers used showed intra-individual variation from weak to moderate, with the higher variation occurring in ears with moderate/severe retraction. The number of tympanic membrane movements was higher during the Valsalva maneuver in the three groups of ears.
72

Emisssões otoacusticas e medidas de imitancia acustica com tons de sonda de 226 e 1.000Hz em neonatos / Otoacoustic emissions and acoustic immitance measurements using 226 and 1000Hz probe tones in neonates

Tazinazzio, Tatiana Guilhermino 15 August 2018 (has links)
Orientadores: Maria Francisca Colella dos Santos, Sergio Tadeu Martins Marba / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-15T13:54:09Z (GMT). No. of bitstreams: 1 Tazinazzio_TatianaGuilhermino_M.pdf: 808223 bytes, checksum: a6dc55813f9697cacf282acb5759a681 (MD5) Previous issue date: 2010 / Resumo: Objetivo: Analisar os resultados encontrados na imitanciometria com tons de sonda de 226 e 1.000Hz em neonatos sem indicadores de risco para perda auditiva (IRPA) e correlaciona-los com as Emissões Otoacústicas Transitórias (EOAT), além de estudar o reflexo acústico com tom de sonda de 226Hz. Métodos: Foram avaliados 52 neonatos a termo, 27 do sexo masculino e 25 do feminino, com faixa etária de 11 a 51 dias de vida. Foram realizadas anamnese, meatoscopia, EOAT, Timpanometria com tons de sonda de 226 e 1000Hz e pesquisa do Reflexo Acústico Ipsilateral. Resultados: Os dados foram analisados independentes de sexo e orelha. Em relação à EOAT, 78,8% estavam presentes. As curvas timpanométricas encontradas com tom de sonda de 226 Hz foram: A (55,8%), D (40,4%), Ar (1,0%), B (2,9%); já com tom de sonda de 1000 Hz encontramos: A (74%), D(1%), B (14,4%) e Bloqueada (10,6%). O reflexo acústico ipsilateral com tom de sonda de 226 Hz estava presente na maioria dos neonatos sem IRPA. Conclusões: Uma relação estatisticamente significante foi encontrada quando comparamos as curvas timpanométricas do tipo A e D (com tom de sonda de 226Hz). E quando comparamos a sonda tipo A e a bloqueada (sonda de 1.000Hz) com a curva tipo B e as relacionarmos com a EOAT foi também estatisticamente significante. Além disso, verificamos uma maior detecção de alteração de orelha média quando a imitanciometria foi realizada com tom de sonda de 1000Hz, do que com a realizada com a de 226Hz. A curva timpanométrica usando a sonda de 1.000Hz mostrou ser mais adequada para detecção de alterações da orelha média que a sonda de 226Hz / Abstract: Objective: To assess the results found in Immittance measurements using 226Hz and 1000Hz in neonates without Hearing Loss Risks Indicators (HLRI) and to correlate them to Transient Evoked Otoacoustic Emissions (EOAT) and also to study Acoustic Reflex using 226Hz probe tones. Methods: Assessments of 52 full - term neonates, being 27 males and 25 females on an age group from 11 to 51 days of life. Anamnese, Meatoscopy, EOAT, Tympanometry using 226 and 1000 probe tones and Ipsilateral Acoustic Reflex Research were performed. Results: Data were analyzed regardless gender and ears. In relation to EOAT (78,8%) were present. Tympanometric curves using 226Hz probe tone found were: A ( 55,8%), D (40,4%) and Ar (1,0%), B (2,9%); and the ones found using 1000Hz probe tone were: A (74%), D (1%), B (14,4%) and Blocked (10,6%). According to p-value, there has been a relation among Tympanometric and general reproductivity. On the sample, 81,7% of the ears indicated presence of Acoustic Reflex. Conclusions: A significant statistically relation was found when it was compared Tympanometric curves types A and D using 226Hz. When it was compared the probe tones types A and blocked (using 1000Hz) to tympanometric curves type B, they were related to the EOAT emissions, which were also statistically significant. Besides, it was also verified a greater detection of changes on middle ear when the immitanciometry was performed using 1000Hz probe tone than the one performed using 226Hz probe tone. Tympanometric curve using 1000Hz probe tone showed to be more adequated for the detection of changes of middle ear than 226Hz probe tone / Mestrado / Saude da Criança e do Adolescente / Mestre em Saude da Criança e do Adolescente
73

Reflectância de orelha média na síndrome de Down / Wideband reflectance in Down syndrome

Jordana Costa Soares 13 August 2013 (has links)
INTRODUÇÃO: A síndrome de Down apresenta elevados índices de alteração da função da orelha média, bem como malformações congênitas na orelha externa, média e interna. Tais condições podem interferir na transmissão sonora pelo sistema tímpano-ossicular até a cóclea e vias auditivas centrais, afetando a compreensão da linguagem falada. Uma recente ferramenta de avaliação da orelha média, a reflectância de energia de faixa ampla, pode quantificar a energia sonora refletida ou absorvida no meato acústico externo ao longo de uma ampla faixa de frequências, mais rapidamente do que a timpanometria. OBJETIVO: Comparar as medidas de reflectância de energia de faixa ampla entre crianças com síndrome de Down e um grupo controle pareado por idade, de acordo com os achados timpanométricos. MÉTODOS: Foram analisados os dados de quatro grupos com síndrome de Down, entre 28 e 195 meses, sendo: timpanometria normal (19 orelhas), timpanometria plana (13 orelhas), timpanometria com pressão negativa moderada (6 orelhas), timpanometria com pressão negativa severa (4 orelhas). Todos os achados foram comparados a um grupo controle (21 orelhas). Os participantes foram submetidos aos exames de timpanometria e reflexo acústico ipsilateral com frequência de sonda de 226 Hz., audiometria tonal limiar, limiar de reconhecimento de fala, emissões otoacústicas evocadas por estímulo transiente e reflectância de energia na faixa de 200 a 6000 Hz. com estímulos do tipo chirp e tons puros. RESULTADOS: Os cinco grupos estudados exibiram diferentes padrões de curvas de reflectância de energia, sem diferença significativa em algumas comparações. Houve correlação negativa entre o volume do meato acústico externo e a reflectância com estímulo chirp entre 250 e 1600 Hz. e com o estímulo de tons puros entre 258 e 1500 Hz., e entre o pico de admitância da timpanometria e a reflectância com estímulo chirp em 500 e 1000 Hz. Não houve correlação entre as frequências da reflectância com estímulo chirp em 1000 e 2000 Hz e os resultados das emissões otoacústicas em 1000, 2000 Hz. e Response. A técnica de análise discriminante utilizada para classificar os dados dos participantes com base nos valores da reflectância com estímulo chirp em 1000 e 1600 Hz., alcançou um índice de classificação correta de 60% para os participantes com síndrome de Down. CONCLUSÕES: Foi possível caracterizar a curva de respostas da orelha média, para diferentes timpanogramas, na síndrome de Down, por meio da reflectância de energia de faixa ampla. Crianças com síndrome de Down com timpanograma normal apresentaram curva de reflectância semelhante ao grupo controle. A análise discriminante por meio dos resultados da timpanometria e reflectância com estímulo chirp em 1600 e 1000 Hz. classificou corretamente 60% dos dados pesquisados nas crianças com síndrome de Down / INTRODUCTION: Children with Down syndrome have high incidence of disorders of the middle ear, as well as congenital abnormalities in the external, middle and inner ear. Such conditions may change the sound transmission through the ossicular chain to the cochlea and central auditory pathways, impairing the comprehension of spoken language. An recent assessment tool of the middle ear, the wideband reflectance energy, can measure the sound energy reflected or absorbed in the ear canal over a wide frequency range, faster than tympanometry. OBJECTIVE: To compare the wideband reflectance measurements between children with Down syndrome and a control group matched by age, according to the tympanometric findings. METHODS: This study evaluated four groups with Down syndrome, between 28 and 195 months: normal tympanogram (19 ears), flat tympanogram (13 ears), moderate negative pressure tympanogram (6 ears), severe negative pressure tympanogram (4 ears). All findings were compared to a control group (21 ears). The subjects underwent to tympanometry and acoustic reflex ipsilateral with a 226 Hz probe tone frequency, pure tone audiometry, speech recognition thresholds, transient otoacoustic emissions and wideband reflectance over the 200-6000 Hz range with chirp and tone stimuli. RESULTS: Results revealed that the five groups had different reflectance curves, without significant difference in some comparisons. There was a negative correlation between the volume of the external auditory meatus and the wideband reflectance with the chirp stimulus between 250 and 1600 Hz and with the tone stimulus between 258 and 1500 Hz, and between the static acoustic admittance at the tympanic membrane level and the wideband reflectance with chirp stimulus at 500 and 1000 Hz. There was no correlation between the frequency of the chirp stimulus with reflectance at 1000 and 2000 Hz and the results of the otoacoustic emissions at 1000, 2000 Hz and general response. The discriminant analysis technique used to classify participants\' data based on the values of reflectance with chirp stimulus in 1000 and 1600 Hz, achieved a correct classification rate of 60% for participants with Down syndrome. CONCLUSIONS: The findings showed the responses of the middle ear, for different tympanograms in Down syndrome through the wideband reflectance. In this study, children with Down syndrome and normal tympanogram showed wideband reflectance curve similar to the control group. A discriminant analysis with the tympanometric results and reflectance with chirp stimulus at 1600 and 1000 Hz correctly classified 60% of the data for children with Down syndrome
74

Efeito da estimulação contralateral nas medidas de reflectância acústica / Effect of contralateral stimulation on acoustic reflectance measurements

Tathiany Silva Pichelli 22 November 2013 (has links)
Introdução: A Reflectância acústica é um procedimento introduzido mais recentemente na clínica audiológica, cuja abrangência diagnóstica pode ainda ser explorada. Suas medidas têm sido citadas como uma importante ferramenta na avaliação das afecções da orelha média, sendo um método considerado vantajoso em relação à timpanometria. Tem havido crescente interesse no estudo da estimulação acústica contralateral e seu efeito na ativação da via eferente auditiva. Estudos têm demonstrado que a introdução de estímulo simultâneo na orelha contralateral gera mudanças no padrão de respostas auditivas, tanto em medidas de emissões otoacústicas como em imitância acústica. Desta forma, surgiu o interesse em investigar a ocorrência de mudanças no padrão de resposta da curva de reflectância, quando pesquisada com a aplicação de ruído de banda larga na orelha contralateral. Objetivo: Verificar a influência da estimulação contralateral nas medidas de reflectância acústica da orelha média em adultos jovens. Metodologia: A casuística foi composta por 30 participantes de ambos os gêneros, na faixa etária de 18 a 30 anos. Procedimentos: Inspeção do meato acústico externo; Imitanciometria; Audiometria tonal limiar; Pesquisa do limiar de ruído branco; Pesquisa da Reflectância Acústica em dois passos: (a) foi obtida a curva de reflectância no intervalo de frequência de 200 a 6000 Hz na intensidade de 60dB SPL utilizando-se os estímulos chirp e de tons puros, e (b) o procedimento foi repetido com os mesmos parâmetros e estímulos, com a presença de ruído contralateral simultâneo por meio de fones de inserção a 30 dBNS em relação ao limiar de ruído branco. Resultados: Os resultados apontaram que não existem diferenças quando comparados gêneros. Quando a análise foi realizada separadamente por orelha houve diferenças entre estímulos chirp e de tons puros nas frequências de 1,5 e 2 kHz em orelha direita. Entre as condições de teste e reteste as diferenças estatísticas foram nas frequências de 0,25 e 0,5 kHz em orelha direita para estímulo de tons puros. A análise entre as condições de teste, reteste e teste com ruído contralateral apresentou diferença estatística na frequência de 2 kHz (pvalor 0,011 em teste e 0,002 em reteste) para estímulo chirp em orelha direita. A comparação entre orelhas esquerda e direita identificou diferenças estatísticas nas frequências de 3 e 4 kHz para os dois tipos de estímulos utilizados. Conclusão: Este estudo permite concluir que a ativação da via auditiva eferente por meio da estimulação acústica contralateral com ruído branco produz mudanças nos padrões de respostas da reflectância acústica, aumentando suas respostas e modificando a transferência de energia sonora da orelha média / Introduction: The acoustic reflectance is a procedure introduced more recently in audiology, which diagnostic scope can be further explored. Its measurements have been cited as an important instrument in the evaluation of middle ear affections, as a method considered advantageous in relation to tympanometry. There has been growing interest in the study of contralateral acoustic stimulation and its effect on activation of the auditory efferent pathway. Studies have shown that the introduction of simultaneous stimulation in the contralateral ear generates changes in the pattern of auditory responses in both measures of otoacoustic emissions as in acoustic impedance. Therefore, emerged the interest in investigating the occurrence of changes in the response pattern of the reflectance curve when studied with the application of broadband noise in the contralateral ear. Objective: Investigate the influence of contralateral stimulation on acoustic reflectance measurements of the middle ear in young adults. Methods: The sample consisted of 30 participants of both genders, aged 18-30 years. Procedures: Inspection of the external acoustic meatus; imitanciometry; pure tone audiometry threshold; threshold research of White Noise; acoustics reflectance research in two steps: (a) obtaining of reflectance curve in the frequency range 200-6000 Hz in the intensity of 60dB SPL using chirp stimuli and pure tone, and (b) repeating the procedure with the same parameters and stimuli with contralateral noise simultaneously through insert earphones at 30 dBNS over the white noise threshold. Results: The results presented no difference compared genres. The analysis performed separately by ear presented differences between chirp stimuli and pure tone at frequencies of 1.5 and 2 kHz in the right ear. Between test and retest conditions the statistical differences in frequencies were at frequencies of 0.25 and of 0.5 kHz in the right ear for pure tone. Analysis of the conditions of test, retest and test with contralateral noise presented statistical difference at the frequency of 2 kHz (pvalue on test 0.011 and 0.002 on retest) for chirp stimulus in the right ear. The comparison between left and right ears identified statistical differences at the frequencies of 3 and 4 kHz for the two types of stimuli used. Conclusion: This study shows that the activation of the efferent auditory pathway by contralateral acoustic stimulation with white noise produces changes in response patterns of acoustic reflectance, increasing their responses and modifying the transfer of sound energy from the middle ear
75

Timpanometria em lactentes utilizando sonda de multifrequência / Multifrequency tympanometry in infants

Tâmyne Ferreira Duarte de Moraes 28 February 2011 (has links)
O objetivo deste trabalho foi realizar a caracterização das medidas de imitância acústica de lactentes de zero a três meses de idade utilizando timpanometria de multifrequência. Foram avaliados 54 lactentes sem queixas auditivas e com presença de emissões otoacústicas evocadas transientes, por meio de entrevista audiológica, inspeção visual do meato acústico externo e medidas de imitância acústica nas frequências de 226Hz, 678Hz e 1000Hz, coletando-se os registros timpanométricos relacionados ao efeito de oclusão, à forma da curva timpanométrica, à pressão de pico timpanométrico, ao volume equivalente do meato acústico externo e ao pico compensado da admitância acústica estática. Os resultados indicaram presença de efeito de oclusão nas três frequências: 2,88% em 226Hz; 4,81% em 678Hz e 3,85% em 1000Hz; predomínio de curva timpanométrica em pico único (65,35% em 226Hz, 81,82% em 678Hz e 77,00% em 1000Hz); pressão de pico timpanométrico variando de -150 a 180daPa, com valores considerados normais; aumento do volume equivalente do meato acústico externo com aumento da frequência da sonda (0,64ml em 226Hz, 1,63mmho em 678Hz e 2,59mmho em 1000Hz), assim como os valores do pico compensado da admitância acústica estática (0,51ml em 226Hz, 0,55mmho em 678Hz e 1,20mmho em 1000Hz). Foram classificados como normais 93,06% dos timpanogramas realizados com 226Hz, 80,81% em 678Hz e 82,00% em 1000Hz. Por meio destas avaliações e resultados encontrados foi possível caracterizar as medidas de imitância acústica dos lactentes. / The aim of this study was to characterize acoustic immittance measures of infants from zero to three months of age using multifrequency tympanometry. 54 infants without hearing complaint and with transient evoked otoacoustic emissions presence were evaluated by an audiologic interview, a visual inspection of the ear canal and measures of acoustic immittance in the frequencies of 226Hz, 678Hz and 1000Hz, where tympanometric records of the occlusion effect, tympanometric curve type, tympanometric peak pressure, equivalent ear canal volume and peak compensated static acoustic admittance were collected. The results indicated presence of occlusion effect in three frequencies: 2.88% at 226Hz, 4.81% at 678Hz and 3.85% at 1000Hz; predominance of tympanometric curve with single peak ( 65.35% at 226Hz, 81.82% at 678Hz and 77.00% at 1000Hz), tympanometric peak pressure ranging from -155 to 180daPa with normal limits, equivalent ear canal volume increase with the frequency of the probe increase (0.64ml at 226Hz, 1.63mho at 678Hz and 2.59mmho at 1000Hz) and the increase of the peak compensated static acoustic admittance values with the frequency increase (0.51ml at 226Hz, 0.55mmho at 678Hz and 1.20mmho at 1000Hz). 93.06% of tympanograms were classified as normal at 226Hz, 81.82% at 678Hz and 77.00% at 1000Hz. Considering these evaluations and results it was possible to characterize the acoustic immittance measures of infants.
76

Reflectância de banda larga em recém-nascidos: uso combinado de procedimentos eletroacústicos / Wideband reflectance in newborns: combined use of electroacoustic procedures

Kilza de Arruda Lyra e Silva 16 December 2011 (has links)
INTRODUÇÃO: Os resultados da triagem auditiva neonatal podem ser afetados por condições transientes no meato acústico externo e na orelha média. A reflectância de banda larga (RBL) surge como um instrumento de diagnóstico que fornece medidas objetivas do estado da orelha média e pode explicar variações na forma de como a orelha média recebe, absorve e transmite a energia sonora. Dessa forma, a RBL apresenta um grande potencial para a detecção de alterações de orelha média em recém-nascidos. OBJETIVO: Verificar a correlação entre as medidas de reflectância da energia de banda larga com as medidas das emissões otoacústicas e as imitanciométricas em recém-nascidos. MÉTODO: Estudo de casos. Para este estudo foram avaliados 77 recém-nascidos (40 do sexo masculino e 37 do feminino) de idades entre 27 e 78h sem riscos para perda auditiva segundo o JCHI (2007), e com emissões otoacústicas presentes por estímulo transiente (EOAT). Foram submetidos ao teste das mediadas de EOAT, da reflectância da energia com os estímulos chirp e tom puro numa faixa de 0.2 a 6 kHz, e da timpanometria e reflexo acústico ipsilateral com as frequências da sonda de 226 e 1000 Hz. Os estímulos ativadores de 1000 e 2000 Hz e ruído de banda larga foram usados no reflexo acústico. RESULTADOS: Os resultados apontaram que os recém-nascidos com EAOT presentes revelaram uma configuração de curva da reflectância com característica peculiar da idade, ou seja, baixa reflectância na frequência de 6000 Hz. O timpanograma de curva do tipo A foi obtido em 90,2% das orelhas com a sonda de 1000 Hz, e com a sonda de 226 Hz a maioria (89%) das orelhas apresentaram curva do tipo pico duplo. A configuração da curva 3B/3G foi apresentada em 69,8% das orelhas na sonda de 226 Hz, e as configurações 1B/1G (43%) e 1B/1G S (27%) juntas foram obtidas em 70% das orelhas. Na sonda de 1000 Hz os recém-nascidos avaliados apresentaram 100% de presença dos reflexos acústicos ipsilaterais para estímulos ativadores de 2000 Hz e ruído branco. Não houve diferença significativa entre os resultados do sexo masculino e do feminino. CONCLUSÃO: Este estudo demonstrou que a inter-relação entre o nível de amplitude das EOAT, a configuração timpanométrica B/G e a reflectância apresentou diferenças no comportamento por orelha. Algumas frequências e configurações B/G indicaram uma tendência da diminuição de EOAT com o aumento da reflectância. Dada a equivalência entre os estímulos chirp e tom puro, qualquer um pode ser usado para avaliação da orelha média em recém-nascidos / INTRODUCTION: Newborn hearing screening test outcomes can be influenced by transient conditions in the ear canal and middle ear. Wideband reflectance (WBR) emerges as a diagnostic tool that provides objective measures of the status of the middle ear and can explain variations in how the middle ear receives, absorbs and transmits sound energy. Thus, the WRL has a great potential for the detection of middle ear disorders in newborns. OBJECTIVE: To verify the correlation between wideband reflectance power measurement with otoacoustic emissions and immittance measurement in newborns. METHOD: Case studies. This study evaluated 77 newborns (40 males and 37 females) aged from 27 to 78 hours without risk of hearing loss according to JCHI (2007), and transient evoked otoacoustic emissions present (TEOAE). The newborns underwent the test of TEOAE measurement, the power reflectance using both tone and chirp stimuli from 0.2 to 6 kHz, and 226 and 1000 Hz admittance probe-tone tympanometry and ipsilateral acoustic reflex. The stimuli triggers 1000 and 2000 Hz and broadband noise were used in the acoustic reflex. RESULTS: Results showed that newborns with EAOT present revealed a configuration of the reflectance curve, peculiar feature of the age, i.e., low reflectance in the frequency of 6000 Hz. Single-peaked tympanogram was obtained in 90.2% of ears using a 1000 Hz probe tone, and double-peaked tympanogram was found in 89% of the ears using a 226 Hz probe tone. The 3B/3G tympanograms were found in 69.8% of the ears at 226 Hz probe tone, and the tympanograms 1B/1G (43%) and 1B/1G S (27%) together were obtained in 70% of the ears. In the 1000 Hz probe tone newborns evaluated showed 100% presence of ipsilateral acoustic reflexes to activating stimuli of 2000 Hz and white noise. No significant differences were obtained across gender considering the results of all test evaluated in newborns. CONCLUSION: This study demonstrated that the inter-relationship between the level of TEOAE amplitude, tympanometric configuration B/G and reflectance showed differences according in the ear. Some frequencies and configurations B/G indicated a trend of TEOAE decreasing of TEOAE with reflectance increasing. Given the equivalence between the tone and chirp stimuli, any of them can be used to evaluate the middle ear in newborns
77

Função da orelha média e das curvas de crescimento nas respostas das emissões otoacústicas / Middle-ear and growth functions on the responses of the otoacoustic emissions

Ualace de Paula Campos 28 June 2011 (has links)
INTRODUÇÃO: Dentre as medidas da função coclear, a curva de crescimento das Emissões Otoacústicas por produto de distorção (CCEOA PD) permite o registro da amplitude da emissão em função do crescimento sistemático nos níveis de tons primários. A CCEOA PD fornece parâmetros específicos sobre o limiar e o comportamento não-linear das EOA PD, porém a variabilidade das respostas inter e intrasujeitos reduz a confiabilidade dessa medida na avaliação da robustez das respostas cocleares e a relação dessa robustez com os limiares auditivos. OBJETIVOS: Esta pesquisa estudou as interações entre as medidas timpanométricas da orelha média e as medidas de função coclear em adultos jovens sem queixas auditivas, de acordo com as variáveis: antecedentes de alterações de orelha média, sexo e orelha direita / esquerda. MÉTODOS: Participaram 69 indivíduos com audição normal e idades entre 18 e 34 anos, sendo 21 homens e 48 mulheres. A caracterização das condições de orelha média foi obtida pela anamnese, com a informação dos antecedentes de alterações de orelha média e pela timpanometria com sondas de admitância de 226 e 1000 Hz. A audiometria foi realizada com resolução de 01 dB NA, o que possibilitou comparações mais refinadas entre o limiar psicoacústico da audiometria tonal, a amplitude do DP-Gram e os limiares das CCEOA PD. Além dessas variáveis, a interferência dos fatores sexo e orelha foram testadas em todas as análises. RESULTADOS/DISCUSSÃO: Os resultados apontaram que as curvas de crescimento sofreram influência significativa das variáveis sexo, antecedentes de alterações de orelha média e orelha direita \\ esquerda, porém, apenas a interferência dos antecedentes foi constante e causou um padrão de modificação, ou seja, o grupo com antecedentes apresentou respostas aquém das respostas do grupo sem antecedentes. Os limiares audiométricos também apresentaram alta correlação com as amplitudes das EOA PD e com os limiares das CCEOA PD, quando identificadas as variáveis que interferiram nos resultados. Considerando que o ruído de fundo foi controlado nessa pesquisa, durante a avaliação das EOA PD e CCEOA PD, os resultados confirmaram a importância da consideração dessas variáveis na composição de grupos com audição normal em pesquisas com medidas de emissões otoacústicas. Ainda sobre os resultados, foi possível, por meio da medida da curva de crescimento (slope e limiar), demonstrar que o padrão de crescimento das CCEOA PD é diferente nos casos de modificação nas condições de orelha média e isso foi verificado tanto pelos antecedentes de alterações de orelha média quanto pelas medidas timpanométricas com sonda de admitância de 1000 Hz. CONCLUSÃO: O limiar das CCEOA - PD estudado nessa pesquisa apresentou correlação positiva com valores audiométricos e negativa com o DP-Gram. A inclinação da curva de crescimento (slope) também apresentou alta correlação com os antecedentes de alterações de orelha média, apontando o potencial valor desta medida no estudo da função coclear saudável e alterada e, conseqüentemente, sua possível utilização nas medidas prescritivas de amplificação / INTRODUCTION: The Distortion Product Otoacoustic Emissions Input/Output function (DPOAE I/O function) is a subdivision of DPOAE, where the response amplitude is recorded such as a systematic growth function in the primary tones. The DPOAE I/O function provides specific parameters about the DPOAEs threshold and non-linearity. However, the response variability reduces the measure reliability to evaluate the cochlear robustness and the relationship between robustness and hearing thresholds. OBJECTIVE: This research studied the interaction between the tympanometric measures and cochlear functions measures in young adults without hearing complaints, considering the variables: middle-ear alteration antecedents, gender and right / left ear. METHODS: 69 normal hearing subjects, aged from 18 to 34 years participated of the study. From the total, 21 were men and 48 women. To reach the proposed objectives, the middle ear conditions were assessed by anamneses and 226 and 1000 Hz admittance probe-tone tympanometry. The audiometric thresholds were searched with 01 dBHL resolution to enable refined comparisons among pure-tone audiometry and DP-Gram amplitude and DPOAE I/O function thresholds. The gender and ear interference were also evaluated in all analyses. RESULTS/DISCUSSION: The results showed that the variables gender, antecedents and ear affected the I/O functions responses, but only the middle-ear alterations antecedents presented a constant modification pattern. In other words, the group with antecedents presented mainly reduced responses in comparison with no antecedents group. The audiometric thresholds also presented high correlation with DPOAE amplitudes and DPOAE I/O functions thresholds, after the detection of the variables affecting the results. As the background noise was controlled during this study, the results confirmed the importance of monitoring these variables in the normal hearing group compositions to perform researches with DPOAE. Regarding the DPOAE I/O functions (slope and threshold), the growth pattern was modified according the middle ear conditions, verified by the antecedents of middle ear alterations and 1000 Hz admittance probe-tone tympanometry. CONCLUSION: The DPOAE I/O function threshold studied presented positive correlation with audiometric thresholds and negative correlation with DP-Gram. The DPOAE I/O functions slope also showed high correlation with antecedents of middle ear alterations, denoting the potential value of this measure in the study of the healthy and damaged cochlear function and, hence, it possible application in amplification prescriptive measures
78

Aspectos fisiologicos e fisicos da orelha como emissora de sons / Physics and physiological aspects of the ear as a sound emitter system

Ferreira, Denise Rezende 29 August 2006 (has links)
Orientadores: Jorge Humberto Nicola, Ester Maria Danielli Nicola / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-07T13:57:05Z (GMT). No. of bitstreams: 1 Ferreira_DeniseRezende_M.pdf: 701948 bytes, checksum: fc978779bb5a79b92989795b47d5a788 (MD5) Previous issue date: 2006 / Resumo: A orelha é o receptor de sons em nosso organismo. O som é captado e conduzido pela orelha externa, amplificado e modulado na orelha média e transformado em sinal elétrico (conhecido como transdução) na orelha interna. Entretanto, as emissões otoacústicas e o zumbido objetivo são exemplos de um processo inverso, onde a orelha se comporta como um emissor de sons. Visando entender alguns destes eventos em que a emissão de sons ocorre, revisou-se a literatura da fisiologia da audição e das bases físicas do percurso do som através do sistema auditivo. Utilizou-se como ferramenta principal, os artigos contidos no Web of Science, dos últimos 25 anos. A partir deste ponto, desenvolveu-se um modelo teórico do percurso do som gerado na cóclea que se propaga em direção à membrana timpânica. Foram realizados cálculos para a atenuação do som decorrente da existência de uma inércia mecânica da estrutura janela oval ¿ ossículos ¿ tímpano. Para isso, considerou-se a razão entre as áreas da janela oval e tímpano e as dimensões dos dois braços de alavanca formada pelos ossículos. Como conclusão, verificou-se que som gerado na cóclea pela eletromotilidade das células ciliadas externas, sofre uma atenuação da ordem de 20 vezes ao passar pela cadeia tímpano-ossicular no sentido inverso. Além disto, demonstrou-se que na interface perilinfa ¿ janela oval, assim como aquela da cadeia ossicular para a membrana timpânica, a transmissão do som é considerável (70%), pois não há grandes diferenças entre as impedâncias acústicas dos meios envolvidos (líquidos labirínticos e sistema tímpano-ossicular). Assim, foi explicado, fisicamente, como as emissões de sons através da orelha podem ter origem a partir de movimentos de muito baixa energia, como aqueles gerados pela contração das células ciliadas externas / Abstract: Ear is the sound receptor in our body. Sound is captured and driven through external ear, amplified and modulated in middle ear and transduced to electrical sign in internal ear. However, otoacoustic emissions and objective tinnitus are examples of an inverse process, where ear can be a sound emitter. Trying to understand some of theses events, in which sound emission occurs, the physiology of hearing and the physical basis to the sound propagation through the ear was revised. It was used as main tool, articles of Web of Science, from the last 25 years. From this point, it was developed a theoretical model to the way of sound, generated inside cochlea that propagates in tympanic membrane direction. It was performed mathematical calculations to sound attenuation, caused by the mechanical inertia of oval window - ossicles - tympanic membrane structure. For that, it was considered the area ratio between oval window and tympanum and the lever action ossicular chain. We concluded that sound generation by electromotility of outer hair cells inside cochlea, is attenuated in 20 times when it passes through ossicular chain in the inverse way. Besides this lost in sound energy, it was also demonstrated that in perilymph-oval window interface sound transmission is considerable (70%), because there are not big differences between the acoustic impedances of involved structures. Then, in physical basis, it was shown how ear can emit sound from contraction of outer hair cells / Mestrado / Otorrinolaringologia / Mestre em Ciências Médicas
79

Evidências de células-tronco na cóclea humana adulta: formação de esferas e presença do marcador de células-tronco ABCG2 / Evidences of stem cells in the human adult cochlea: sphere formation and identification of ABCG2

Milene Massucci Bissoli 05 October 2016 (has links)
A cóclea humana adulta é reconhecidamente incapaz de se regenerar de modo significativo na prática clínica após uma lesão. Tal fato se explica pela perda da capacidade de proliferação de suas células sensoriais após o período neonatal. Em diferentes espécies de mamíferos neonatos, foi demonstrada a capacidade de proliferação das células sensoriais cocleares através de ensaios de formação de esferas e da presença de marcadores para células-tronco, como o ABCG2. Neste estudo, foram utilizadas cócleas humanas adultas para ensaio de formação de esferas e para a pesquisa do marcador de células-tronco ABCG2 através de citometria de fluxo. As cócleas foram obtidas de pacientes portadores de schwannomas vestibulares submetidos a procedimento cirúrgico para ressecção do tumor via translabiríntica e doadores de órgãos em morte encefálica. Foi possível observar formação de esferas in vitro e identificar o marcador ABCG2 através de citometria de fluxo nas células dissociadas do tecido coclear / The human cochlea is, allegedly, unable to regenerate after trauma due to the loss of the proliferation capacity after the neonatal period. It has been demonstrated in different neonatal mammal species that sensorial cochlear cells retain their proliferation capacity in the neonatal period using sphere-formation assays and stem cell markers such as ABCG2. In the present work, human adult cochleas have been used for sphereformation assay and flow cytometric identification of ABCG2. Human adult cochleas have been removed either from patients undergoing vestibular schwannoma resection via translabyrinthine approach or brain-dead organ donors. There have been identified sphere formation in vitro and the stem cell marker ABCG2 in flow cytometry analysis after cochlear dissociation
80

Análise comparativa da influência do pericôndrio no crescimento conjuntival sobre enxertos de cartilagem auricular em reconstrução palpebral: estudo experimental em coelhos / Comparative analysis of the influence of perichondrium on conjunctival epithelialization on cartilage grafts in eyelid reconstruction: experimental study in rabbits

Santos, Marcelus Vinicius de Araujo 11 June 2008 (has links)
Enquanto o papel dos enxertos cartilaginosos na reconstrução da lamela interna palpebral está bem estabelecido, o crescimento da conjuntiva sobre ele, proveniente de áreas adjacentes, necessita de comprovação mais aprofundada. Este estudo tem como objetivos analisar comparativamente, após a reconstrução palpebral inferior com enxertos de cartilagem auricular conchal com e sem pericôndrio, em ambas as pálpebras inferiores de coelhos, a presença de crescimento conjuntival sobre os enxertos, a área de epitelização conjuntival sobre eles, a integridade da estrutura corneana dos globos oculares em contato com os enxertos cartilaginosos e a presença de alterações das áreas dos enxertos de cartilagem com e sem pericôndrio, após sua implantação. Foram utilizados, para o experimento, 50 coelhos albinos adultos da raça New Zealand (Oryctolagus cuniculus), entre 3 e 4 meses de vida, com pesos médios variando de 2,5 a 3,0 quilogramas no início do experimento, provenientes do biotério da Faculdade de Medicina da Universidade de São Paulo. Cem pálpebras inferiores foram reconstruídas em sua lamela interna, com enxertos autógenos de cartilagem auricular conchal, e cobertos com retalho miocutâneo. As pálpebras do lado direito receberam enxerto de cartilagem com pericôndrio posicionado em contato direto com o globo ocular, enquanto as do lado esquerdo foram reconstruídas da mesma forma, porém com enxertos cartilaginosos sem pericôndrio. A cada semana, em um total de 5 semanas, eram sacrificados 10 animais após a reconstrução palpebral, e suas pálpebras inferiores foram analisadas macroscópica e histologicamente. A planimetria digital demonstrou que, com 5 semanas, a área média das cartilagens com pericôndrio apresentava redução de 8,33%, e a área média das cartilagens sem pericôndrio encontravase reduzida em 18,52%. Detectou-se, em cada semana de avaliação, que as áreas das cartilagens com pericôndrio se apresentaram significativamente maiores do que aquelas sem pericôndrio nas semanas 4 e 5 (p=0,0003 e p=0,0001, respectivamente), e uma tendência para significância na semana 2 (0,0706). Na primeira e terceira semanas, a diferença entre as áreas se manteve igual (p=0,8583 e p=0,2092). Em relação ao crescimento conjuntival, observouse que a diferença porcentual do crescimento sobre as cartilagens com e sem pericôndrio foi de 11,41% na primeira semana do experimento, de 13,64% na segunda semana, de 18,69% na terceira, de 10,38% na quarta, e de 6,17% na quinta. Observou-se, em cada semana do experimento, que a porcentagem média de crescimento da conjuntiva nas pálpebras reconstruídas com enxerto condro-pericondral apresentou-se significativamente maior do que aquelas apenas com enxerto cartilaginoso nas 5 semanas do experimento (p<0,0001). Observou-se que houve crescimento conjuntival sobre os enxertos de cartilagem em contato direto com o globo ocular, ocorrendo tanto nas cartilagens com pericôndrio, como naquelas que não o possuíam. A área de cobertura conjuntival com 5 semanas nas cartilagens com pericôndrio, foi maior do que a observada nas cartilagens sem pericôndrio. Não houve ceratite ou úlceras de córnea na maioria da amostra estudada e houve diminuição das áreas dos enxertos cartilaginosos em graus variados, com maior intensidade nos enxertos sem pericôndrio. / Although the role of cartilage grafts in reconstruction of the posterior eyelid lamella is well established, conjunctival epithelialization on such grafts has yet to be fully proven. The aim of this study is to perform a comparative analysis, after inferior eyelid reconstruction in rabbits with cartilage grafts with and without perichondrium, the presence of conjunctival epithelialization over conchal cartilage grafts, the area of conjunctival epithelialization over those grafts, the integrity of the corneal structure in contact with the cartilage grafts and the variation of the areas of the cartilage grafts with and without perichondrium. Fifty adult albino New Zealand rabbits (Oryctolagus cuniculus) between 3 and 4 months of age with average weights from 2.5 to 3.0 kilograms from the University of São Paulo Medical School animal colony were used for the experiment. The posterior lamellae of 100 lower eyelids from were reconstructed with autogenous grafts of conchal ear cartilage and covered with a myocutaneous flap. In the right eyelids, cartilage was grafted with the perichondrium in direct contact with the eyeball, while the left eyelids were reconstructed in a similar manner but using cartilage grafts without perichondrium. The animals were sacrificed after 1, 2, 3, 4 and 5 weeks after eyelid reconstruction, and their lower eyelids were analyzed macroscopically and histologically. The digital planimetry has demonstrated that in the first week of the experiment there was a reduction of 8,33%, in the average area of the cartilages with perichondrium and a reduction of 18,52% in the average area of the cartilages with perichondrium. The average areas of the cartilages with perichondrium were significantly larger than those on cartilages without perichondrium in weeks 4 and 5 (p=0,0003 and p=0,0001, respectively) and tended to vary over the week 2 (0,0706). No difference was noted between the areas in weeks 1 and 3 (p=0,8583 and p=0,2092). When the conjunctival growth was assessed, it was found that the percentage difference in conjunctival epithelialization on the cartilage with perichondrium and that without perichondrium was 11.41% in the first week of the experiment, 13.64% in the second week, 18.69% in the third, 10.38% in the fourth and 6.17% in the fifth. The average percentage conjunctival epithelialization in the eyelids reconstructed with a cartilage graft with perichondrium was significantly higher for the five weeks of the experiment than that in the eyelids reconstructed with cartilage without perichondrium (p<0.0001). It was found that there was conjunctival growth on the cartilage grafts with and without perichondrium when they were placed in direct contact with the eye. The area of the epithelialization on cartilages with perichondrium was larger than that on cartilages without perichondrium in week 5. Neither keratitis nor corneal ulcers were observed during the 5 weeks of the experiment in the majority of the animals operated on and there was reduction in the areas of the grafts in various degrees, with larger intensity in the grafts without perichondrium.

Page generated in 0.0505 seconds