• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • 17
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 65
  • 24
  • 19
  • 14
  • 13
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Dimensões do Nursing Role Effectiveness Model no acompanhamento dos resultados de pacientes submetidos à artoplastia do quadril / Nursing role effectiveness model dimensions in the follow-up of the patients outcomes undergoing to hip arthroplasty

Silva, Marcos Barragan da January 2017 (has links)
A avaliação de resultados voltada aos cuidados de saúde surge pela necessidade das profissões demonstrarem a sua efetividade nos resultados dos pacientes. Diversas abordagens têm sido utilizadas para identificar as relações entre as variáveis de Estrutura, Processo e Resultado na avaliação da qualidade do cuidado no contexto hospitalar. Pesquisadoras canadenses desenvolveram o Nursing Role Effectiveness Model (NREM), para auxiliar na identificação da contribuição da enfermagem aos cuidados de saúde. O NREM ainda não foi utilizado na perspectiva do Processo de Enfermagem Avançado, utilizando os Sistemas de Linguagem Padronizada NANDA-I, NIC e NOC para pacientes submetidos à Artroplastia do Quadril. Este estudo teve como objetivo analisar as relações entre as dimensões do Nursing Role Effectiveness Model no acompanhamento dos resultados de pacientes submetidos à Artroplastia do Quadril. Trata-se de um estudo longitudinal, aninhado a um desenho correlacional descritivo. Os dados foram coletados no Hospital de Clínicas de Porto Alegre. A população e amostra consistiram em pacientes submetidos à Artroplastia do Quadril, e enfermeiros assistenciais que prescreveram os cuidados a estes pacientes. No estudo longitudinal, os pacientes foram acompanhados por três a quatro dias consecutivos de pós-operatório, entre os meses de Março e Dezembro de 2016. Os enfermeiros foram entrevistados nos meses de Janeiro e Fevereiro de 2017. Os dados foram analisados estatisticamente. Os achados foram categorizados segundo as dimensões do NREM Estrutura, Processo e Resultado. Resultado: Foram incluídos 85 pacientes predominantemente do sexo feminino (58%), com média de idade de 64 (±13,5) anos. Na dimensão Estrutura, os pacientes foram diagnosticados, segundo a NANDA International (NANDA-I) com Dor Aguda (96%), Risco de Quedas (62%) e Mobilidade Física Prejudicada (54%), respectivamente. A maioria dos pacientes estava em repouso numa Cama Ortopédica (99%). Enfermeiros tinham uma idade média de 33 anos, Sendo a maioria (90%). Experiência com pacientes ortopédicos variou de um a seis anos. O nível de conhecimento na NANDA-I, NIC e NOC foi considerado de moderado a substancial. As intervenções de enfermagem, de acordo com a Nursing Interventions Classification (NIC) mais prescritas foram: Controle da DOR, Prevenção de QUEDAS e POSICIONAMENTO (Processo). Os Resultados da Nursing Outcomes Classification (NOC) (Posicionamento do corpo: autoiniciado, Mobilidade, Conhecimento: atividade prescrita e Nível de dor), tiveram mudanças significativas (P<0,001) durante o acompanhamento dos pacientes. As escalas apresentaram consistência interna (α>0,7). Conclui-se que as variáveis de Estrutura, Processo e Resultados, elencadas neste estudo, possuem relação; e de acordo com os efeitos que geram nos resultados alcançados no paciente, apresenta repercussões na qualidade do Processo de Enfermagem Avançado baseado nos Sistemas de Linguagem Padronizada NANDA-I, NIC e NOC para pacientes submetidos à Artroplastia do Quadril. / The evaluation of health outcomes arises from the need for professions to demonstrate their effectiveness in patient outcomes. Several approaches have been used to identify the relationships between the Structure, Process and Outcomes variables in the quality care evaluation in the hospital. Canadian researchers to developed the Nursing Role Effectiveness Model (NREM) to identify the nursing contribution to health care. The NREM was not analyzed from the perspective of the Advanced Nursing Process, using the Standardized Language Systems NANDA-I, NIC and NOC for patients undergoing Hip Arthroplasty. This study aimed to analyze the relationships between the dimensions of the Nursing Role Effectiveness Model in the follow-up of the outcomes of patients undergoing for Hip Arthroplasty. It is a longitudinal study nested for descriptive correlative design. The data were collected at Hospital de Clínicas de Porto Alegre, Brazil. The population and sample consisted of patients undergoing to Hip Arthroplasty, and nurse assistants who prescribed care for these patients. In the longitudinal study patientes were followed for three to four postoperative day, on the March to December 2016. Nurses were interviewed in January and February 2017. Data were statistically analyzed. The findings were categorized according to the dimensions Structure, Process and Outcomes, from NREM. Results: Variables Structure, were included 85 patients predominantly female (58%), mean age 64 (± 13.5) years. The patients were diagnosed with Acute Pain (96%), Risk of Falls (62%) and Impaired Physical Mobility (54%), respectively. The majority of patients were resting in the Orthopedic Bed (99%). Nurses had a mean age of 33 years, being the majority (90%) female. Experience with orthopedic patients ranged from one to six years. Knowledge level in NANDA-I, NIC and NOC was considered moderate to substantial. The most prescribed NIC nursing interventions were: PAIN Control, FALL Prevention and POSITIONING, considered as Process variables. The Nursing outcomes NOC (Body Positioning: self-initiated, Mobility, Knowledge: prescribed activity and Pain Level) included in the Outcome dimension from NREM, had significant changes (P <0.001) during the follow-up. The scales showed internal consistency (α> 0.7). It is concluded that the Structure, Process and Outcomes variables are related and according to the effects it generates on the outcomes achieved, it has repercussions on the Advanced Nursing Process quality based on the Standardized Language Systems NANDA- I, NIC and NOC for patients submitted to Hip Arthroplasty.
62

Análise da carga microbiana nos instrumentos utilizados em cirurgias ortopédicas / Analysis of the microbial load in the instruments used in orthopedic surgeries

Flávia Morais Gomes Pinto 29 April 2009 (has links)
O insucesso nos procedimentos cirúrgicos ortopédicos em razão de infecção pode levar a consequências desastrosas como a osteomielite e a perda de próteses implantadas. A infecção hospitalar é um desfecho de causa multifatorial, na qual a esterilização segura do instrumental cirúrgico ocupa uma posição de extrema importância. Não se sabe até o momento quais os reais desafios microbiológicos que a Central de Material e Esterilização (CME) vem enfrentando ao reprocessar a diversidade dos materiais utilizados nos procedimentos cirúrgicos. Micro-organismos com capacidade para esporular estão presentes em quantidade e frequência significativa? Sabe-se que estes se constituem como desafio mensurável na prática da esterilização, fazendo parte de indicadores biológicos. O objetivo desta pesquisa foi determinar e analisar a carga microbiana recuperada do instrumental cirúrgico, após uso em cirurgias ortopédicas, quantificando e identificando o gênero e a espécie do crescimento de bactérias e fungos. A investigação caracterizou-se como uma pesquisa exploratória, de campo e transversal com abordagem quantitativa. As amostras foram coletadas no Instituto de Ortopedia e Traumatologia (IOT) do Hospital das Clínicas (HC) da Faculdade de Medicina da Universidade de São Paulo (FMUSP), com técnica asséptica, depositando-as individualmente em um saco plástico previamente esterilizado, adicionando 500 mL de água de injeção. Para obtenção da carga microbiana, o instrumental foi sonicado em lavadora ultrassônica (US) por três sessões de 5 segundos cada e, consecutivamente, agitado por 5 minutos para complementar a extração da carga microbiana potencialmente presente na superfície dos materiais (externa e internamente). Em seguida, os lavados foram divididos em três partes iguais e submetidos à filtração em filtro Millipore® de 0,45 µm. Cada membrana foi cultivada em meio apropriado para o crescimento aeróbio, anaeróbio e fungos/leveduras. Para a identificação dos micro-organismos, foram utilizados kits e testes de identificação utilizados na rotina laboratorial de microbiologia clínica. Os resultados demonstraram que os três diferentes potenciais de contaminação apresentaram crescimento microbiano. Nas cirurgias limpas, 47% do instrumental estavam contaminados e o micro-organismo mais prevalente foi o Staphylococcus coagulase negativa (28%), seguido do Bacillus subtilis (11%). Nas cirurgias contaminadas e infectadas, houve um crescimento, de aproximadamente, 70% e 80%, respectivamente nos instrumentos, sendo maior o crescimento do Staphylococcus coagulase negativa (respectivamente, 32% e 29%) e Staphylococcus aureus (respectivamente, 28% e 43%). Considerando que os gêneros Bacillus e o Clostridium são capazes de esporularem, concluiu-se que a CME enfrenta um desafio ao precisar eliminar micro-organismos capazes de esporular, em uma densidade 102 UFC, menor que a dos indicadores biológicos e, aproximadamente, 78% dos micro-organismos recuperados foram bactérias vegetativas com sua curva de morte em torno de 80 ºC / The failure in orthopedic surgical procedures due to infection can lead to devastating consequences such as the loss of implanted prostheses. Hospital infection is an outcome with a multifactorial cause, in which the safe sterilization of the surgical instruments has an extremely important role. To date, it is not known what microbiological challenges the Material and Sterilization Center (MSC) has been facing when reprocessing the variety of materials used during these surgical procedures. Are microorganisms with the capacity to sporulate present in significant quantity and frequency? It is known that these microorganisms constitute a measurable challenge in sterilization practice and that they are part of the biological indicators. This study aimed at measuring the microbial load recovered from surgical instruments after their use in orthopedic surgeries, quantifying and identifying the genus and species of the bacterial and fungal growth. The study was characterized as an exploratory research, field research and cross-sectional with quantitative approach. The samples were collected at the Institute of Orthopedics and Traumatology (IOT) of Hospital das Clínicas (HC) of the School of Medicine of the University of São Paulo (FMUSP), using an aseptic technique, the samples were then placed in a plastic bag that had been previously sterilized with 500 mL of injection solution. To obtain the microbial load, the instruments were sonicated in an ultrasonic (US) washer for three 5-second sessions each and consecutively agitated for 5 minutes to complement the extraction of the microbial load potentially present on the surface of the materials (external and internally). Subsequently, the washed samples were fragmented in three equal parts and these were submitted to filtration in a 0.45 µm Millipore® filter. Each membrane was cultured in medium adequate for the growth of aerobic and anaerobic organisms, as well as fungi and yeasts. The identification of the microorganisms was carried out with identification kits and tests used in clinical microbiology laboratory routine. The results demonstrated that the three different contamination potentials presented microbial growth. In clean surgeries, 47% of the instruments were contaminated and the most prevalent microorganism was coagulase-negative Staphylococcus (28%) followed by Bacillus subtilis (11%). In contaminated and infected surgeries, a growth of approximately 70% and 80%, respectively, was identified in the instruments, with the higher growth being that of coagulase-negative Staphylococcus (respectively, 32% and 29%) and Staphylococcus aureus (respectively, 28% and 43%). Considering that the Bacillus and the Clostridium genera are capable of sporulating, we concluded that the MSC faces a challenge in having to eliminate microorganisms capable of sporulating, although in a lower density than that of biological indicators (102 UFC) and, approximately, 78% of the recovered microorganisms were vegetative bacteria that presented their curve of death at around 80ºC
63

Avaliação das exposições médicas e ocupacionais em cirurgias ortopédicas por meio do método Monte Carlo

Santos, Felipe Amorim 22 February 2018 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Clinical settings for vertebral compression fracture surgery were virtually modeled to estimate equivalent, effective, and cancer risk values normalized by the KAP (Kerma Product Area) for the patient and surgeon. This surgery is known as kyphoplasty and involves the use the equipament of type arch C, which provides real-time imaging and supports the surgeon during needle manipulation and delivery of surgical cement into the fractured vertebra. The radiation transport code used was MCNPX (Monte Carlo N-Particle eXtended) and two dual virtual anthropomorphic simulators: UFHADM and UFHADF (University of Florida Hybrid ADULT Male / Female). Two projections were simulated with seven tube voltage voltages for each. In the same scenario the KAP was calculated at the tube output, providing the calculation of the conversion coefficients (E/KAP, HT/KAP and RC/KAP). From the knowledge of experimental values of KAP and the results presented in this study, it was possible to estimate absolute values of equivalent, effective dose and cancer risk for different exposure conditions. In this work, scenarios were developed with and without the surgical table, in order to compare it with the existing data in the literature. The absence of the bed in the scenario promoted a percentual increase of 56% in the effective doses of patients in relation to the scenarios calculated with the bed. Regarding the surgeon, considering all projections, the use of personal protective equipment reduced the effective dose, on average, between 66-68%; while the use of the UTS reduced this same greatness by 2-5%. In relation to the study of cancer risk, colon and lung presented as a higher risk organ for the patient and surgeon, respectively. For the simulator undergoing kyphoplasty (pacient), considering a beam of 70 kVp, KAP of 5.5 Gy.cm2 and a effective cancer risk coefficient calculated in this work of 3.77 Gy-1.cm-2, it was estimated 21 cancer deaths were estimated, considering a universe of 106 cases. The data obtained in this work emphasize the importance of elaborating virtual scenarios that resemble clinical scenarios, generating E/KAP, HT/KAP and RC/KAP values that are closer to the real values. / Cenários clínicos para cirurgia de fratura por compressão da vértebra foram virtualmente modelados para estimar valores de dose equivalente, efetiva e risco de câncer normalizados pelo PKA (Produto Kerma Área) para o paciente e cirurgião. Esta cirurgia é conhecida como cifoplastia e envolve o uso do equipamento de radiodiagnóstico do tipo arco C, o qual fornece imagens em tempo real e dá suporte para o cirurgião durante a manipulação das agulhas e entrega de cimento cirúrgico dentro da vértebra fraturada. O código de transporte de radiação utilizado foi o MCNPX (Monte Carlo N-Particle eXtended) e duas duplas de simuladores antropomórficos virtuais: UFHADM e UFHADF (University of Florida Hybrid ADult Male/Female). Foram simuladas duas projeções com sete tensões de tubo para cada uma. No mesmo cenário foi calculado o PKA na saída do tubo, proporcionando o cálculo dos coeficientes de conversão (E/PKA – Dose Efetiva por PKA, HT/PKA – Dose equivalente por PKA e RC/PKA – Risco de Câncer por PKA). A partir do conhecimento de valores experimentais de PKA e dos resultados deste estudo, foi possível estimar valores absolutos de dose equivalente, efetiva e risco de câncer para diferentes condições de exposição. Neste trabalho foram desenvolvidos cenários com e sem a mesa cirúrgica, para comparação com os dados já existentes na literatura. A ausência da mesa no cenário promoveu um aumento percentual de 56% nos CCs de doses efetivas de pacientes em relação aos cenários calculados com a cama. Com relação ao cirurgião, considerando todas as projeções, o uso dos equipamentos de proteção pessoal reduziu a dose efetiva, em média, entre 66-68%; enquanto o uso do saiote reduziu entre 2-5% esta mesma grandeza. Em relação ao estudo de risco de câncer, o cólon e pulmão apresentaram-se como órgãos de maior risco para o paciente e médico cirurgião, respectivamente. Para o simulador submetido a cirurgia de cifoplastia (paciente), considerando um feixe de 70 kVp, PKA de 5,5 Gy.cm2 e um o coeficiente de risco de câncer efetivo calculado neste trabalho de 3,77 Gy-1.cm-2, estimou-se 21 mortes por câncer, considerando um universo de 106 casos. Os dados obtidos enfatizam a importância da elaboração de cenários virtuais que se assemelham a cenários clínicos, gerando valores de E/PKA, HT/PKA e RC/PKA mais próximos dos valores reais. / São Cristóvão, SE
64

Avaliação da eficácia da esterização de furadeiras elétricas domésticas utilizadas em cirurgias ortopédicas / Evaluation of the efficacy of the sterilization of ordinary electric drills for orthopedic surgeries

Vania Regina Goveia 20 December 2007 (has links)
Estima-se que há mais de 50 anos, as furadeiras elétricas (FE) têm sido empregadas em cirurgias ortopédicas nos hospitais brasileiros para a perfuração óssea. Trata-se de equipamento elétrico, termossensível, não indicado para uso cirúrgico, não avaliado anteriormente quanto à eficácia da esterilização, suspeitando-se de risco potencial para infecções do sítio cirúrgico ou relacionadas a próteses ortopédicas. Os objetivos desse estudo foram: avaliar a carga microbiana de FE do uso cirúrgico e avaliar a eficácia da esterilização por óxido de etileno (ETO) de FE novas intencionalmente contaminadas. Trata-se de pesquisa experimental, laboratorial, randomizada e aplicada desenvolvida no laboratório de pesquisas experimentais da Escola de Enfermagem da Universidade de São Paulo. O trabalho foi realizado em duas fases. As condições assépticas foram rigorosamente seguidas para o controle das variáveis. Quinze FE analisadas na fase I, tiveram distribuição aleatória e cega, capturadas em um centro cirúrgico de um hospital escola. Foram cultivados: o ar gerado pelo motor e alíquotas de 10 µL do lavado das superfícies interna e externa das FE. Ainda nessa fase foi realizado um controle positivo onde uma FE foi contaminada com Serratia marcescens e um teste do método de filtração por membrana de porosidade de 0,45 µm com uma FE limpa, onde as membranas que filtraram diferentes quantidades do lavado foram cultivadas. Na fase II foram analisadas 22 FE e três perfuradores de osso (PO). Dezesseis FE constituíram o grupo experimental (GE), seis o controle positivo (GCP) e três PO constituíram o controle negativo (GCN). Todos os equipamentos previamente limpos e esterilizados foram submetidos à contaminação com esporos de Bacillus atrophaeus. As FE do GCP foram analisadas após a exposição ao contaminante, furadeiras do GE e perfuradores do GCN foram submetidos à limpeza e esterilização por ETO antes de serem analisados. Foram cultivados: ar gerado pelo motor e membrana filtrante após a filtração do lavado das superfícies interna e externa dos equipamentos. Foram realizadas coloração e microscopia: Gram para culturas positivas; Wirtz-Conklin para culturas positivas com bacilos Gram positivos. Os resultados mostraram que a carga microbiana de FE do uso cirúrgico é baixa e foi detectada em duas ocasiões no cultivo do ar, 1 ufc/FE e em uma ocasião no cultivo de alíquotas do lavado, 9 ufc/FE. O controle positivo realizado com Serratia marcescens comprovou a sensibilidade do método para amostras contendo alta concentração de contaminantes. O método filtração por membrana mostrou-se sensível para detectar baixa contaminação das FE, sendo o eleito para o teste de esterilidade. Os controles positivos apresentaram crescimento do microrganismo contaminante, comprovando a aderência ao material. Os controles negativos não apresentaram crescimento. Das 16 FE do GE, duas apresentaram crescimento sendo cada uma delas de 1ufc do contaminante inicial respectivamente no cultivo do ar e no cultivo da membrana. Foi comprovada a eficiência de 99,99999881% do processo de esterilização por ETO, com a probabilidade de sobrevivência de 1,19 x 10-8. Nas condições do desenvolvimento do experimento, a eficácia da esterilização das FE por ETO foi comprovada / Electric drills have been used to perform orthopedic surgeries in Brazilian hospitals for almost more than 50 years. This electric equipment is heat-sensitive and it is not appropriate to use in surgical procedures. Until now the efficacy of sterilization of this item had been not evaluated as a potential risk for the occurrence of surgical site infection or infection related to orthopedic prosthesis. The objectives of this study were to evaluate the bioburden of the used electric drills and to evaluate the sterility of the new electric drills contaminated artificially. It is an experimental and randomized study performed in the research laboratory of the Nursing School of the São Paulo University. The study was performed in two phases following rigorous aseptic techniques to control the variables. In the first phase fifteen electric drills were taken in the operating room of the university hospital and included in the study using aleatory and blind methods. Cultures were performed from the air produced by the drill engine and the aliquots of 10µL of the rinsed water from the internal and external surface of the electric drill. One electric drill was included as a positive control and was contaminated with Serratia marcescens. A membrane filter with porous of 0,45 µm were cultured after had been exposed to the rinsed water from the internal and external surface of the clean electric drill. In the second phase were analyzed twenty two electric drills and three orthopedic drilling machines. Sixteen electric drills were included in the experimental group, six were the positive control group and three orthopedic drilling machines in the negative control group. All the equipments previously cleaned and sterilized were submitted to the contamination with Bacillus atrophaeus. The electric drills included in the positive control group were analyzed after exposed to the contaminant and the electric drills of the experimental group and orthopedic drills included in the negative control group were submitted to clean and ethylene oxide sterilization before to start the analysis. The air produced by the drill engine and the membrane filter after exposed to the rinsed water of the internal and external surface of the electric drill were cultured. It was performed Gram microscopy and Wirtz-Conklin to Gram positive bacilli. The results showed low bioburden in the electric drills in two episodes. So, 1 cfu/electric drill was found in one episode of the air culture and 9 cfu/electric drill in one episode of culture of the aliquot. The positive control with Serratia marcescens demonstrated the sensibility of the method in samples with high concentration of contaminants. The method of membrane filtration showed sensible to detect low bioburden of the electric drills. So it is elected for the sterility test. The positive controls showed the growth of the contaminant microrganism demonstrating the adherence to the material surface. The negative controls did not show growth. Two of the sixteen electric drills included in the experimental group showed each one growth of 1cfu of the initial contaminant of the air and the membrane cultures respectively. So the efficiency of the sterilization process was 99,99999881% and the probability of find survivor was 1,19 x 10-8. In these conditions the study demonstrates that the efficacy of the ethylene oxide sterilization was proved
65

PREVALÊNCIA DE ALTERAÇÕES ÓSSEAS NO TARSO DE POTROS CRIOULOS DE ATÉ VINTE E SEIS MESES DE IDADE / PREVALENCE OF BONE CHANGES IN THE TARSUS OF CRIOULO YEARLINGS UP TO 26 MONTH OF AGE

Gallio, Miguel 28 February 2013 (has links)
The Crioulo horse industry has increased exponentially in the last few years, this scenario, leads horse breeders to neglect individual aspects of the horse s development, interfering, mostly, in the nutritional management, as younger animals are participating in halter shows. These changes in horse management without considering individual aspects of growth, feeding and exercise level predispose these animals to the complex of diseases known as developmental orthopedic diseases. Radiographs were taken of both tarsi of 77 (31 fillies and 46 colts), of nine up to 26 months old Crioulo horses, competing or not in halter events. These young horses were divided in groups by age, with one including nine to 18 months old foals (G1) (34/77) and the other 19 to 26 months old ones (G2) (43/77). According to preparation or not for halter competition, horses were divided into GI (48/77) (average preparation time 4.55 months) and GC (control group, 29/77), respectively. Data were collected on 24 breeding farms or training centers, to determine the prevalence of osteoarticular changes. The results showed that 77.22% (61/77) presented some degree of radiographically visible lesions. The prevalence of lesions in males was 80.44%, 77.42% in females; 77.31% in the GC; 79.17% in the GI; 86.67% in G1 and 76.75% in G2. The mean body weight of the 10 to 12 month old yearlings (G1) was 293.25kg, representing 71.28% of the mature weight and that of the 19 to 26 month old ones (G2) was 360.5kg (87.71% of mature weight), the mean body weight of GC was 288.9kg (70.22% of the mature weight), and that of GI was 341.9kg (83.11% of the mature weight), even with the mean age of both groups being 16.79 and 18.98 months, respectively. A significant relationship was found between the animal s weight gain (p= 0.02; r= 0.26), body condition score (p= 0.03; r= 0.23), neck crest score (p= 0.018; r= 0.27) and wither s height (p= 0.01; r= 0.28) and the degree of the radiographic lesions found in the tarsi. Several factors can be involved in distal tarsal juvenile osteoarthritis; however the most important factor present in Crioulo breeding farms was the horse s overweight. / O comércio do cavalo Crioulo tem crescido de forma exponencial nos últimos anos, este cenário de valorização dos animais desta raça induz os proprietários e criadores a interferirem profundamente no manejo, principalmente nutricional, destes animais, decorrente da participação de potros e animais adultos em exposições e competições morfológicas. A interferência no manejo dos animais não levando em conta os aspectos individuais do desenvolvimento, sem controle exato da alimentação fornecida e do nível de exercício exigido predispõem os animais ao complexo de doenças conhecido como doenças ortopédicas do desenvolvimento. Foram examinados radiograficamente os tarsos de 77 animais (31 fêmeas e 46 machos), com nove até 26 meses de idade, participantes ou não de exposições ou competições morfológicas. Os animais foram divididos em grupos por idade, um incluindo potros de nove a 18 meses (G1) (34/77) e outro com animais de 19 a 26 meses (G2) (43/77), e pelo tempo de preparo para exposição morfológica em grupo controle (GC) (29/77) (sem preparo para exposição) e grupo incentivo (GI) (48/77), com preparo médio de 4,55 meses. Os dados foram coletados em 24 propriedades de criação ou centros de treinamento/preparo, para determinar a prevalência de alterações osteoarticulares. Observou-se que 77,22% (61/77) apresentaram alguma lesão radiograficamente visível. A prevalência de lesões articulares foi de 80,44% nos machos, 77,42% nas fêmeas, 77,31% nos animais do GC, 79,17% dos animais do GI, 86,67% nos animais do G1 e 76,75% nos animais do G2. O peso médio aos 10 a 12 meses de idade foi de 293,25kg, representando 71,28% do peso adulto e dos animais com idade de 19 a 26 meses o peso médio foi de 360,5kg (87,62% do peso adulto), nos animais do GC o peso médio foi de 288,9kg (70,22% do peso adulto) e os animais do GI apresentaram peso médio de 341,9kg (83,11% do peso adulto), mesmo a idade média dos dois últimos grupos tendo sido de 16,79 meses e 18,98 meses respectivamente. Foi constatada relação entre o aumento do peso dos animais (p= 0,02; r= 0,26), do escore corporal (p= 0,03; r= 0,23), do escore de deposição de gordura na crista do pescoço (p= 0,018; r= 0,27) e da altura (p= 0,01; r= 0,28) com as lesões radiográficas no tarso dos potros. Vários fatores podem estar envolvidos na osteoartrite társica distal, entretanto, o fator mais importante presente nas criações de cavalos Crioulos, é o sobrepeso.

Page generated in 0.0763 seconds