• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • 17
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 65
  • 24
  • 19
  • 14
  • 13
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Moto-boys de Porto Alegre : convivendo com os riscos do acidente de trânsito

Veronese, Andréa Márian January 2004 (has links)
Esta dissertação tem por objetivo geral investigar de que modo os moto-boys vêem o risco do acidente de trânsito no seu cotidiano de trabalho, na cidade de Porto Alegre. O estudo foi realizado com base nas teorias sociológicas sobre ‘risco’, em especial as que enfatizam o caráter sociocultural dos seus significados. A pesquisa foi desenvolvida numa perspectiva qualitativa e seguiu os procedimentos metodológicos da Teoria Fundamentada nos Dados. A técnica de grupo focal foi a estratégia utilizada para a coleta dos dados. Os resultados da análise apontam que os ‘riscos do acidente de trânsito’ são produzidos por interesses pessoais e sociais no sentido das demandas por velocidade e urgência em relação ao interesse em ganhar mais e se manter empregado. Os moto-boys consideram os riscos de acidente de trânsito inerentes ao cotidiano do seu trabalho e tentam controlar estes riscos utilizando estratégias de autocuidado.
32

Bupivacaína racêmica a 0,5% e mistura com excesso enantiomérico de 50% (S75-R25) a 0,5% no bloqueio do plexo braquial para cirurgia ortopédica : estudo comparativo / Roberto Tsuneo Cervato Sato ; orientador, Luiz Carlos Von Bahten

Sato, Roberto Tsuneo Cervato January 2007 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2007 / Bibliografia: f. 56-60 / JUSTIFICATIVA E OBJETIVOS: Com a finalidade de encontrar uma droga mais segura que a bupivacaína racêmica, vários estudos foram realizados com seus isômeros. Este estudo tem como objetivo avaliar a eficácia da mistura com excesso enantiomérico de 50% (MEE / JUSTIFICATION & OBJECTIVES: In order to find a safer drug than racemic bupivacaine, many studies have been done into its isomers. This study aims to assess the effectiveness of a mixture with an enantiomeric excess of 50% (MEE50%) of bupivacaine (S75-R25
33

Placas ósseas confeccionadas a partir de diáfise cortical equina na osteossíntese femoral em coelhos = Bone plates produced from equine cortical bone in rabbits femoral osteosynthesis / Fernando Pinheiro Milori ; orientador, Antônia Maria do Rocio Binder do Prado / Bone plates produced from equine cortical bone in rabbits femoral osteosynthesis

Milori, Fernando Pinheiro January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, São José dos Pinhais, 2010 / Inclui bibliografias / A evolução tecnológica tem possibilitado o desenvolvimento e o aperfeiçoamento de novos materiais para implantes. Apesar dos fundamentais benefícios providos pelos dispositivos ortopédicos, complicações decorrentes de corrosão, degradação, infecção, além / Actually, technological advances have contributed to the development and improvement of new materials for implants. Despite the fundamental benefits provided by orthopedic materials, complications resulting from corrosion, degradation, infection, and othe
34

Tratamento das fraturas da diáfise do úmero: osteossíntese com placa em ponte versus tratamento não cirúrgico com órtese funcional. Ensaio clínico randomizado / Treatment of the humeral shaft fractures - minimally invasive osteosynthesis with bridge plate versus conservative treatment with functional brace. A randomised controlled trial

Matsunaga, Fabio Teruo [UNIFESP] January 2015 (has links) (PDF)
Submitted by Diogo Misoguti (diogo.misoguti@gmail.com) on 2016-06-24T15:17:45Z No. of bitstreams: 1 2015-12-doutorado-fabio-teruo-matsunaga.pdf: 1999766 bytes, checksum: 32c62a76d06379cb082b6dcfd95ba755 (MD5) / Approved for entry into archive by Diogo Misoguti (diogo.misoguti@gmail.com) on 2016-06-24T15:18:31Z (GMT) No. of bitstreams: 1 2015-12-doutorado-fabio-teruo-matsunaga.pdf: 1999766 bytes, checksum: 32c62a76d06379cb082b6dcfd95ba755 (MD5) / Made available in DSpace on 2016-06-24T15:18:31Z (GMT). No. of bitstreams: 1 2015-12-doutorado-fabio-teruo-matsunaga.pdf: 1999766 bytes, checksum: 32c62a76d06379cb082b6dcfd95ba755 (MD5) Previous issue date: 2015 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: O tratamento não cirúrgico é, atualmente, considerado o método de escolha para a maioria das fraturas da diáfise do úmero, apesar de pacientes tratados com órtese funcional poderem apresentar resultados insatisfatórios. A osteossíntese com placa em ponte tem se mostrado uma técnica segura, com bons resultados. Objetivo: Avaliar a efetividade do tratamento das fraturas da diáfise do úmero, com placa em ponte (PP), em comparação com a órtese funcional (OR), considerando-se a função do membro superior. Métodos: Pacientes com fraturas da diáfise do úmero foram aleatoriamente alocados em um dos dois grupos. Os alocados no grupo PP foram encaminhados para o tratamento cirúrgico, com técnica conforme descrita por LIVANI, BELANGERO (2004). Os pacientes alocados no grupo OR foram tratados com órtese funcional, após 14 dias de uso de tala gessada. Todos os pacientes foram submetidos ao mesmo programa de reabilitação e acompanhados por até um ano. O desfecho primário foi a função do membro superior avaliada pelo questionário The Disabilities of the Arm, Shoulder and Hand (DASH). Como desfechos secundários, avaliamos a qualidade de vida, pelo questionário SF-36, complicações, dor, avaliada pela escala visual analógica, função do ombro, medido pelo escore Constant e radiografias. Resultados: Cento e dez pacientes foram incluídos no estudo. Houve diferença estatística favorável ao grupo PP, no DASH, após seis meses. No entanto, essa diferença não foi clinicamente significante. Não foi possível detectar diferença entre os grupos no questionário SF-36, dor, Constant e deformidade residual nas radiografias, incidência em perfil. Quanto à ocorrência de pseudartrose, tempo de consolidação e deformidade radiográfica residual no plano coronal, houve uma superioridade do grupo PP. Conclusão: Não houve diferença clínica entre o tratamento com PP com OR, quanto à função do membro superior, com um ano após intervenção. / Background: Conservative treatment is still considered the standard treatment of the majority of humeral shaft fractures. However, patients treated with this method can present unsatisfactory results. Minimally invasive bridge plate osteosynthesis have been showing a safe technique with good results. Objective: To investigate the effectiveness of surgical treatment of humeral shaft fractures with bridge plating in comparison to conservative treatment with functional brace, considering upper limb function. Method: Patients with humeral shaft fractures were allocated, after randomization, to one of the two groups. The ones allocated in bridge plate group were sent to surgical treatment, according to technique described by LIVANI and BELANGERO (2004). Patients allocated in nonoperative treatment were treated with functional brace after 14 days of initial cast immobilisation. All patients were included in the same rehabilitation program and were followed up for 1 year after intervention. Primary outcome was the DASH score. As secondary outcomes, we assessed , SF-36 questionnaire, treatment complications, Constant score, pain and radiographs. Results: one hundred and ten patients were included. Statistical difference was found in DASH scores favourable to bridge plate group 6 months after treatment. This difference was not clinically relevant. We could not detect difference between both groups in SF-36 questionnaire, pain, Constant score and radiographic deformity in lateral view. Nonunion rates, time of fracture healing and residual deformity in coronal plane were favourable to bridge plate group. Conclusion: Surgical treatment with bridge plating showed similar results compared to functional brace, considering upper limb function, one year after intervention.
35

Avaliação de microplacas de titânio em fraturas de tibiotarso em pombos domésticos (Colimba livia)

Gouvea, Aline Silva January 2010 (has links)
Entre os problemas cirúrgicos das aves, as fraturas são os de maior prevalência. Em virtude das variações no tamanho, peso, anatomia óssea peculiar, alta incidência de fraturas complicadas e às diferentes demandas funcionais entre espécies e indivíduos, não foi possível estabelecer ainda um método ideal de osteossíntese para os ossos longos das aves. Por isso, diversos estudos têm sido realizados buscando um método adequado para as diferentes necessidades desses animais. Microplacas de titânio comumente utilizadas em cirurgias maxilofaciais de humanos foram empregadas recentemente na osteossíntese de aves, porém com poucos resultados disponíveis. O objetivo do presente estudo foi avaliar a utilização das microplacas de titânio no tratamento de fraturas experimentais de tibiotarso em pombos domésticos (Columba livia). Foram utilizadas 30 aves, adultas, machos e fêmeas, com 7 meses de idade, pesando entre 400 a 500 gramas, oriundas do Biotério Central da Universidade Federal de Santa Catarina (UFSC). Os animais foram separados aleatoriamente em 3 grupos de dez animais, sendo que no grupo 1 foi utilizado uma microplaca de titânio com 6 furos e espaçador central, no grupo 2 com 8 furos sem espaçador central e no grupo 3 com 8 furos com espaçador central. Após avaliação clínica, as aves foram submetidas a osteotomia médio-diafisária no tibiotarso direito para colocação das diferentes configurações de microplaca de titânio, sendo fixadas com microparafusos de titânio com 7mm de comprimento. Os animais foram avaliados clinica e radiograficamente até os 90 dias de pós-operatório. Após esse período, foi realizada eutanásia em 2 animais de cada grupo. Em todos animais foi observado a consolidação óssea, no grupo 1 o tempo médio e o desvio padrão foram 32,9±9,9; no grupo 2 30,8±6,7 e no grupo 3 26,6±6,4 dias, não havendo diferença estatística entre os grupos. O envergamento do implante foi a complicação mais frequente. A configuração da microplaca resultou em diferença estatística significativa em relação a deambulação e ao grau de envergamento nos diferentes grupos. Sendo que no grupo 3 houve maior precocidade no apoio do membro e menor grau de envergamento em relação aos outros grupos. Histologicamente foi verificado formação de calo ósseo em todos animais e presença de tecido ósseo ao redor da microplaca e microparafusos. Apesar das complicações observadas as microplacas de titânio são uma opção para osteossíntese de tibiotarso em aves de médio porte. / Among the surgical problems in birds, the fractures are the most prevalent. Due to variations in size, weight, peculiar bone anatomy, high incidence of complicated fractures and the functional demands of different species and individuals, is not possible yet to establish an ideal method for osteosynthesis of long bones in birds. Therefore, several studies have been conducted looking for a suitable method for the different needs of these animals. Titanium microplates commonly used in human maxillofacial surgery have been recently employed in osteosynthesis of birds, but with few results available. The aim of this study was to evaluate the use of titanium microplates in the treatment of tibiotarsus fractures in pigeons (Columba livia) 30 birds were used, adult males and females, with 7 months old, weighing from 400 to 500 that came from the Animal Center Facility of the Federal University of Santa Catarina (UFSC). The animals were divided into 3 groups with ten animals each. In group 1 a titanium microplate with 6 holes and a central spacer were used; in group 2 a titanium microplate with 8 holes without a spacer in the center; in group 3 a titanium microplate with 8 holes with central spacer. After clinical evaluation, the birds were submitted to mid-diaphyseal osteotomy in the right bone for placement of different configurations of the titanium plate, and fixed with titanium microscrews 7mm long. The animals were evaluated clinically and radiographically until 90 days postoperatively. After this period, euthanasia was performed in 2 animals from each group. In all animals was observed bone healing and in group 1 the mean and standard deviation were 32.9 ± 9.9, in group 2 30.8 ± 6.7 in group 3 26.6 ± 6.4 days, not having statistical difference in healing time between groups. The bending of the implant was the most common complication. The configuration of the plate resulted in a statistically significant difference in relation to walking and the degree of bending in different groups. Moreover, in group 3 there was higher precocity in the member suppor and a lower degree of bending in relation to other groups. Histologically it was verified the formation of the callus in all animals and the presence of bone tissue around the plate and microscrews. Despite the complications of titanium microplates, they are an option for osteosynthesis of tibiotarsus in birds of medium size.
36

Avaliação de microplacas de titânio em fraturas de tibiotarso em pombos domésticos (Colimba livia)

Gouvea, Aline Silva January 2010 (has links)
Entre os problemas cirúrgicos das aves, as fraturas são os de maior prevalência. Em virtude das variações no tamanho, peso, anatomia óssea peculiar, alta incidência de fraturas complicadas e às diferentes demandas funcionais entre espécies e indivíduos, não foi possível estabelecer ainda um método ideal de osteossíntese para os ossos longos das aves. Por isso, diversos estudos têm sido realizados buscando um método adequado para as diferentes necessidades desses animais. Microplacas de titânio comumente utilizadas em cirurgias maxilofaciais de humanos foram empregadas recentemente na osteossíntese de aves, porém com poucos resultados disponíveis. O objetivo do presente estudo foi avaliar a utilização das microplacas de titânio no tratamento de fraturas experimentais de tibiotarso em pombos domésticos (Columba livia). Foram utilizadas 30 aves, adultas, machos e fêmeas, com 7 meses de idade, pesando entre 400 a 500 gramas, oriundas do Biotério Central da Universidade Federal de Santa Catarina (UFSC). Os animais foram separados aleatoriamente em 3 grupos de dez animais, sendo que no grupo 1 foi utilizado uma microplaca de titânio com 6 furos e espaçador central, no grupo 2 com 8 furos sem espaçador central e no grupo 3 com 8 furos com espaçador central. Após avaliação clínica, as aves foram submetidas a osteotomia médio-diafisária no tibiotarso direito para colocação das diferentes configurações de microplaca de titânio, sendo fixadas com microparafusos de titânio com 7mm de comprimento. Os animais foram avaliados clinica e radiograficamente até os 90 dias de pós-operatório. Após esse período, foi realizada eutanásia em 2 animais de cada grupo. Em todos animais foi observado a consolidação óssea, no grupo 1 o tempo médio e o desvio padrão foram 32,9±9,9; no grupo 2 30,8±6,7 e no grupo 3 26,6±6,4 dias, não havendo diferença estatística entre os grupos. O envergamento do implante foi a complicação mais frequente. A configuração da microplaca resultou em diferença estatística significativa em relação a deambulação e ao grau de envergamento nos diferentes grupos. Sendo que no grupo 3 houve maior precocidade no apoio do membro e menor grau de envergamento em relação aos outros grupos. Histologicamente foi verificado formação de calo ósseo em todos animais e presença de tecido ósseo ao redor da microplaca e microparafusos. Apesar das complicações observadas as microplacas de titânio são uma opção para osteossíntese de tibiotarso em aves de médio porte. / Among the surgical problems in birds, the fractures are the most prevalent. Due to variations in size, weight, peculiar bone anatomy, high incidence of complicated fractures and the functional demands of different species and individuals, is not possible yet to establish an ideal method for osteosynthesis of long bones in birds. Therefore, several studies have been conducted looking for a suitable method for the different needs of these animals. Titanium microplates commonly used in human maxillofacial surgery have been recently employed in osteosynthesis of birds, but with few results available. The aim of this study was to evaluate the use of titanium microplates in the treatment of tibiotarsus fractures in pigeons (Columba livia) 30 birds were used, adult males and females, with 7 months old, weighing from 400 to 500 that came from the Animal Center Facility of the Federal University of Santa Catarina (UFSC). The animals were divided into 3 groups with ten animals each. In group 1 a titanium microplate with 6 holes and a central spacer were used; in group 2 a titanium microplate with 8 holes without a spacer in the center; in group 3 a titanium microplate with 8 holes with central spacer. After clinical evaluation, the birds were submitted to mid-diaphyseal osteotomy in the right bone for placement of different configurations of the titanium plate, and fixed with titanium microscrews 7mm long. The animals were evaluated clinically and radiographically until 90 days postoperatively. After this period, euthanasia was performed in 2 animals from each group. In all animals was observed bone healing and in group 1 the mean and standard deviation were 32.9 ± 9.9, in group 2 30.8 ± 6.7 in group 3 26.6 ± 6.4 days, not having statistical difference in healing time between groups. The bending of the implant was the most common complication. The configuration of the plate resulted in a statistically significant difference in relation to walking and the degree of bending in different groups. Moreover, in group 3 there was higher precocity in the member suppor and a lower degree of bending in relation to other groups. Histologically it was verified the formation of the callus in all animals and the presence of bone tissue around the plate and microscrews. Despite the complications of titanium microplates, they are an option for osteosynthesis of tibiotarsus in birds of medium size.
37

Moto-boys de Porto Alegre : convivendo com os riscos do acidente de trânsito

Veronese, Andréa Márian January 2004 (has links)
Esta dissertação tem por objetivo geral investigar de que modo os moto-boys vêem o risco do acidente de trânsito no seu cotidiano de trabalho, na cidade de Porto Alegre. O estudo foi realizado com base nas teorias sociológicas sobre ‘risco’, em especial as que enfatizam o caráter sociocultural dos seus significados. A pesquisa foi desenvolvida numa perspectiva qualitativa e seguiu os procedimentos metodológicos da Teoria Fundamentada nos Dados. A técnica de grupo focal foi a estratégia utilizada para a coleta dos dados. Os resultados da análise apontam que os ‘riscos do acidente de trânsito’ são produzidos por interesses pessoais e sociais no sentido das demandas por velocidade e urgência em relação ao interesse em ganhar mais e se manter empregado. Os moto-boys consideram os riscos de acidente de trânsito inerentes ao cotidiano do seu trabalho e tentam controlar estes riscos utilizando estratégias de autocuidado.
38

Material particulado, microbiota aérea e perfil de resistência de Staphylococcus aureus em suspensão durante o intra-operatório de cirurgias ortopédicas em um hospital de médio porte de São Carlos, SP

Almeida, Cristiane Leite de 22 January 2010 (has links)
Made available in DSpace on 2016-06-02T19:48:16Z (GMT). No. of bitstreams: 1 2825.pdf: 1262073 bytes, checksum: b2962d5f301de96324cede3691966cb9 (MD5) Previous issue date: 2010-01-22 / The control of surgical site infection, especially during clean is important, especially when exposed bone in orthopedic surgery. A study was conducted exploratory study aimed to assess the impact of particulate matter, air and microbial resistance profile of Staphylococcus aureus in suspension for the intraoperative orthopedic procedures in a medium-sized hospital in São Carlos, SP. In the initial ten samples, the results indicate presence of filamentous fungi in 69% of the samples and 93.75% of the bacterial samples were identified as Gram positive and Gram negative 6.25%. In the 10 samples analyzed in the second stage, the UFC's of bacteria had an average of 97.80%, standard deviation of 51.60%, coefficient of variation of 52.75% and range between 21 and 178. We identified the presence of Staphylococcus aureus, Staphylococcus spp. and Shigella spp. 25%, 75% and 25% of samples, respectively. Held an antibiotic for Staphylococcus aureus isolated from the air in the operating room, and found that the strain had high levels of resistance to most antibiotics used, with sensitivity only two of 15 antimicrobial agents tested. The presence of suspended particles was above the recommended standard for the surgery, suggesting the need for an effective control of air quality. It was observed that during surgery there was a significant increase in suspended particles in accordance with WHO standards and CONAMA. The increase in the number of the surgical team in the room probably generated an increase of suspended particles and hence an increase in microbial range. Of the surgeries performed, one can see that in 70% of the operating room door was closed and 50% with air conditioning was off. In 3 (60%) of surgeries in which the air conditioning was off, we found the incidence of a bacterial genus. / O controle da infecção do sítio cirúrgico, principalmente em cirurgias limpas, é relevante, principalmente quando há exposição óssea, em cirurgias ortopédicas. Foi realizado um estudo exploratório e prospectivo que objetivou verificar a incidência de material particulado, microbiota aérea e perfil de resistência de Staphylococcus aureus em suspensão durante o intra-operatório de cirurgias ortopédicas em um hospital de médio porte de São Carlos, SP. Nas dez amostras iniciais, os resultados demonstraram presença de fungos filamentosos em 69% das amostras e 93,75% das amostras bacterianas foram identificadas como Gram positivas e 6,25% Gram negativas. Nas 10 amostras realizadas na segunda etapa, as UFC s de bactérias apresentaram média de 97,80%, desvio padrão de 51,60%, coeficiente de variação de 52,75% e amplitude entre 21 e 178. Foram identificadas a presença de Staphylococcus aureus, Staphylococcus spp. e Shigella spp. em 25%, 75% e 25% das amostras, respectivamente. Realizou-se um antibiograma para Staphylococcus aureus isolados do ar da sala cirúrgica, e verificou-se que a bactéria apresentou elevados índices de resistência a maioria dos antibióticos utilizados, com sensibilidade apenas a dois dos 15 antimicrobianos testados. A presença de material particulado em suspensão estava acima do padrão recomendado durante o intra-operatório, sugerindo a necessidade de um controle efetivo da qualidade do ar. Observou-se que durante os procedimentos cirúrgicos houve um aumento considerável do material particulado em suspensão, de acordo com padrões da OMS e CONAMA. O aumento no número de pessoas da equipe cirúrgica na sala provavelmente gerou um aumento de material particulado em suspensão e, conseqüentemente, um aumento na variedade microbiana. Das cirurgias realizadas, pode-se verificar que em 70% destas, a porta da sala cirúrgica encontrava-se fechada e 50% estava com ar condicionado desligado. Em 3 (60%) das cirurgias em que o ar condicionado estava desligado, observou-se a incidência de um gênero bacteriano.
39

Avaliação do crescimento ósseo em implantes de titânio revestidos por plasma spraying com diferentes interfaces metal-filme

Cunha, Alexandre January 2008 (has links)
Made available in DSpace on 2013-08-07T18:53:51Z (GMT). No. of bitstreams: 1 000400633-Texto+Parcial-0.pdf: 244771 bytes, checksum: 929e01919e85f7195f849c8c0c09bddc (MD5) Previous issue date: 2008 / Titanium and its alloys are widely applied as orthopedic and dental materials implants because of their excellent biocompatibility, low elastic modulus and high corrosion and wear resistance. The main causes that influence the adequate biomaterial functionality are the bone tissue growth and its adhesion to the implant surface. Recent researches indicated that the adhesion between the living bone tissue and the implant is related to the surface roughness, due to surface modifications, and the increasing of bone ingrowths in this region. These surface modifications are achieved mostly by deposition of porous coating using thermal spraying technique, application of blasting of ceramic particulates and acid and electrochemical etchings. The main goal of this research is to estimate the osseointegration of titanium porous coating in contact with sheep cortical bone, as well as to evaluate the bone conductive behavior of these coatings. The second goal is to evaluate the adhesive strength of the titanium porous coatings deposited on modified surfaces of titanium coin shaped implants. X-ray fluorescence (XRF) and xray dispersive energy spectroscopy (EDS) were applied to verify the chemical composition of the Ti implants, titanium porous coatings and osseointegrated titanium implants. Scanning electron microscope (SEM) was applied to characterize the morphology of titanium coin shaped implants, titanium porous coating and the bone tissue/titanium porous coatings/titanium implants interface. Pull out tests were applied to evaluate the osseointegration and the adhesion of porous coatings on the surface of titanium coin shaped implants. The rupture tension values verified for titanium porous coatings are higher than the values verified for titanium implants without porous coatings (RENZ, 2007), mainly after 30 days of healing. The titanium porous coatings etched with HF showed the highest rupture tension values when compared with titanium porous coatings as deposited. The adhesion values of titanium porous coatings increased for modified surfaces when compared with the adhesion values verified for the machined surfaces. / Titânio e suas ligas são amplamente aplicados como materiais de implantes ortopédicos e odontológicos devido a sua excelente biocompatibilidade, baixo módulo de elasticidade e alta resistência ao desgaste e à corrosão. Os fatores que influenciam decisivamente a adequada funcionalidade de um biomaterial são o crescimento do tecido ósseo e a sua adesão à superfície do implante. Pesquisas recentes indicam que o processo de adesão entre o implante e o tecido vivo depende da rugosidade superficial, devido à modificação da sua superfície, e do crescimento ósseo nesta região. Essas modificações são alcançadas principalmente com a deposição de revestimentos porosos por aspersão térmica, a aplicação de jateamentos com particulados cerâmicos, ataques ácidos e eletroquímicos, entre outros. O objetivo específico desta pesquisa é estimar a osseointegração de filmes porosos de titânio em contato com a cortical óssea de ovinos, bem como avaliar o comportamento do processo de osseocondução desses filmes. O segundo objetivo é avaliar a adesão destes filmes porosos de titânio depositados sobre superfícies modificadas de discos de titânio. As técnicas de fluorescência de raios X e espectroscopia por energia dispersiva de raios X foram aplicadas para verificar a composição química dos implantes, filme de titânio e implantes osseointegrados.A Microscopia Eletrônica de Varredura foi usada para caracterizar a morfologia dos discos de Ti, filme de titânio e a interface tecido ósseo/filme de titânio/metal-base. Testes de tração foram aplicados para avaliar a osseointegração dos filmes de titânio e a adesão destes aos discos. Os valores de tensão de ruptura estimados para os filmes de titânio são superiores aos verificados em discos sem revestimento poroso de titânio (RENZ, 2007), principalmente no período de 30 dias pós-operatório. Os filmes de titânio atacados com ácido fluorídrico apresentaram os maiores valores de tensão de ruptura da interface osso-filme quando comparados aos filmes somente depositados, indicando aumento da osseointegração. Os valores de adesão dos filmes de titânio para as superfícies modificadas são maiores que os valores de adesão na superfície somente usinada.
40

Aplicação de filmes finos de titânio em componentes acetabulares de uhmwpe para proteção contra oxidação devido a exposição à radiação X

Vasconcellos, Letícia Araújo January 2006 (has links)
Made available in DSpace on 2013-08-07T18:54:53Z (GMT). No. of bitstreams: 1 000383160-Texto+Completo-0.pdf: 3194550 bytes, checksum: cc6dcfdfc93d7782e5f949d40152d488 (MD5) Previous issue date: 2006 / The use of multi-component hip implants to replace the femur head is widespread since the 70’s. These implants consist basically of a spherical metallic head and a stem, which are generally made of the same material, mostly 316-L stainless steel or Cr-Co alloys. This system is fitted into a polymeric component (UHMWPE) and implanted, which reestablishes the bone motion. One of the major causes of implant rejection is the generation of UHMWPE debris on the surface between the implant head and the polymeric component. The use of gamma rays sterilization of the implants and the periodical x-ray medical control could contribute to the premature degradation of the polymeric surface, resulting in quick wear and short lifetime of the implant. The main goal of this work is to study the protection grade of titanium thin films deposited on UHMWPE samples as a function of diagnosis x-ray exposition, comparing it with non-coated polymers, which were exposed to the same radiation. A group of samples were bathed on Hanks Balanced Salt Solution (HBSS), which is frequently used on cell cultures, since it simulates the physiological environment of human organism. The samples were analyzed by diverse characterization techniques as nanohardness, permitting to assess the surface mechanical properties of the polymer samples; scanning electron microscopy (SEM), to observe to superficial quality of the UHMWPE samples and Fourier transform infrared spectroscopy (FTIR) to evaluate chemical composition alterations of the polymer samples. After the samples being irradiated, they were used on the first part of this work were nanohardness tests were conducted resulting on diverse mechanical properties of the UHMWPE samples, varying from batch to batch. SEM analysis indicated two clear facts: firstly, Ti coated UHMWPE samples presented a superficial quality with less damage due to de x-ray exposition. Considering the obtained results it can be concluded that a thin titanium layer could decrease the UHMWPE superficial oxidation, confirming the initial hypothesis. / Os implantes de quadril são constituídos de uma cabeça esférica metálica que e. g., é de aço inoxidável 316-L ou ligas de Cr-Co, além de um componente polimérico (UHMWPE). A aplicação da radiação gama usada no processo de esterilização e dos raios X de diagnóstico utilizados no controle clínico da prótese podem contribuir na degradação prematura da superfície do UHMWPE resultando numa diminuição do seu tempo de vida útil. Neste trabalho, foi estudado o grau de proteção de revestimentos tipo filme fino de titânio sobre o componente polimérico (UHMWPE) em função da exposição aos raios X de diagnóstico, comparando-os com os polímeros não revestidos que também foram expostos ao mesmo tipo de radiação. Parte destas amostras foram submersas em uma solução de HBSS (Hank’s Balanced Salt Solution), a qual é freqüentemente utilizada em culturas de células, pois simula o meio fisiológico do organismo humano. As amostras foram analisadas por diversas técnicas de caracterização, dentre elas, a técnica de nanodureza para uma análise das propriedades mecânicas do polímero, microscopia eletrônica de varredura (MEV) para observação da qualidade superficial do UHMWPE e infravermelho por transformada de Fourier (FTIR) para avaliação das modificações na composição química do polímero. Após serem irradiadas, as amostras utilizadas na primeira parte do trabalho, os resultados dos testes de nanodureza levaram a concluir que as propriedades mecânicas do UHMWPE variam de lote para lote. As análises de MEV indicaram dois fatos claros: primeiramente que as amostras revestidas apresentavam uma qualidade superficial com menos danos que as amostras revestidas em concordância com as análises de nanodureza e FTIR. Desta forma, com base nos resultados obtidos, podemos concluir que nossa hipótese inicial, de que uma fina camada de titânio pode diminuir a oxidação superficial do UHMWPE, é verdadeira.

Page generated in 0.0642 seconds