• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 12
  • 2
  • 1
  • Tagged with
  • 28
  • 28
  • 14
  • 13
  • 13
  • 10
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da qualidade de vida relacionada à saúde de pacientes portadores de marca-passo / Evaluation of the health-related quality of life of patients with pacemakers

Gonçalo, Sumaya dos Santos 28 June 2018 (has links)
Introdução: Pretende-se com a estimulação cardíaca artificial promover melhor qualidade de vida a portadores de complicações cardíacas graves, porém, a falta de conhecimento dos pacientes e o despreparo dos profissionais de saúde podem influenciar nos hábitos de vida e no surgimento de possíveis complicações. Objetivo: Avaliar a qualidade de vida relacionada à saúde (QVRS) de pacientes portadores de marca-passo (MCP) e explorar as associações entre QVRS e variáveis sociodemográficas, clínicas e sintomas de ansiedade e depressão. Método: Estudo observacional analítico, de corte transversal, realizado em hospital universitário do interior paulista. Uma amostra consecutiva e não probabilística foi constituída de pacientes de ambos os sexos, maiores de 18 anos, portadores de MCP há pelo menos um mês. Para a avaliação da QVRS, foi utilizado um instrumento genérico (SF-36) e um específico (AQUAREL). Para investigarmos a associação da QVRS com o sexo e o estado civil, utilizamos o teste t de Student. Para QVRS com a idade, o tempo de implante de MCP e os sintomas de ansiedade e de depressão, utilizamos o teste de Correlação de Pearson. O nível de significância foi de 0,05. Resultados: Participaram 88 pacientes, maioria do sexo masculino e com companheiro. Sua média de idade foi 64,3 (DP=13,0). Utilizando o SF-36, o domínio que apresentou maior média foi \"Aspectos Sociais\", e a menor, \"Aspectos Físicos\". Utilizando o AQUAREL, o domínio de maior média foi \"Arritmia\", e o de menor, \"Dispneia\". Quanto às associações, as mulheres apresentaram menores médias nos domínios \"Capacidade Funcional\", \"Estado Geral de Saúde\", \"Vitalidade\", \"Saúde Mental\" e \"Componente Mental\" do SF-36, bem como nos domínios \"Arritmia\" e \"Dispneia\" do AQUAREL, com significância estatística. Os pacientes sem companheiro apresentaram menores médias nos domínios \"Capacidade Funcional\", \"Vitalidade\" e \"Aspectos Sociais\" do SF-36, e nos domínios \"Arritmia\" e \"Dispneia\" AQUAREL, com significância estatística. Quanto à idade, as correlações foram significativas com os domínios \"Capacidade Funcional\" e \"Aspectos Físicos\" do SF-36, com baixa força de correlação. Quanto ao tempo de implante de MCP, as correlações foram significativas com o domínio \"Capacidade Funcional\" do SF-36 e com o domínio \"Arritmia\" do AQUAREL, com baixa força da correlação. Quanto à correlação da QVRS com os sintomas de ansiedade, foi significativa com os oito domínios do SF-36 e com os dois componentes, negativa, de forte magnitude no domínio \"Saúde Mental\" e no Componente Mental, e moderada em outros seis domínios. A correlação da ansiedade com os três domínios do AQUAREL foi negativa, significativa e de moderada magnitude. Quanto à correlação da depressão com a QVRS, foi significativa com os oito domínios do SF-36 e com os dois componentes, negativa, de forte magnitude no domínio \"Saúde Mental\" e moderada magnitude em quatro domínios e no Componente Mental. A correlação da depressão com os três domínios do AQUAREL foi negativa, significativa e de moderada magnitude. Conclusão: Os pacientes apresentaram pior QVRS nos domínios que avaliaram o quanto as condições físicas interferem no dia-a-dia. As mulheres, os pacientes sem companheiro e com maior sintomatologia de ansiedade e depressão apresentaram pior avaliação. / Introduction: Artificial cardiac stimulation aims to offer a better quality of life to those with severe cardiac problems. However, the lack of knowledge of the patients and the lack of preparation of health professionals can influence the life habits and lead to the surfacing of potential complications. Objective: Evaluating the health-related quality of life (HRQOL) of patients who have pacemakers (PM) and explore the associations between HRQOL and sociodemographic and clinical variables and symptoms of anxiety and depression. Method: Observational, analytical and cross-sectional study, conducted in a teaching hospital in the countryside of the state of São Paulo. A consecutive non-probabilistic sample was created including male and female patients above 18 years old who had had an MP for at least a month. To evaluate their HRQOL, a generic (SF-36) and a specific (AQUAREL) instruments were used. To investigate the association of HRQOL with sex and marital status, Student\'s t-test was used, and to analyze its relationship to age, time since MP implantation, and depression and anxiety symptoms, Pearson\'s Correlation Coefficient was used. The significance level was 0.05. Results: 88 patients participated, most were male and had partners. Age average was 64.3 (SD=13.0). The SF-36 domain with the highest average was \"Social Aspects\", and the one with the lowest, \"Physical Aspects\". The greatest average among AQUAREL domains was \"Arrythmia\", and the lowest, \"Dyspnea\". As to associations, women presented lower averages in the domains \"Functional Capabilities\", \"General Health State\", \"Vitality\", \"Mental Health\" and \"Mental Component\" of the SF-36. The same was true for AQUAREL domains \"Arrythmia\" and \"Dyspnea\", all these correlations statistically significant. Patients with no partners had statistically significant lower averages in the SF-36 domains \"Functional Capabilities\", \"Vitality\" and \"Social Aspects\", and in the AQUAREL domains \"Arrythmia\" and \"Dyspnea\". As to their age, correlations were significant with the SF-36 domains \"Functional Capabilities\" and \"Physical Aspects\", with low-strength correlations. As to the time passed since the PM implantation, low-strength correlations were significant in the SF-36 domain \"Functional Capabilities\" and the AQUAREL domain \"Arrythmia\". As to the correlation of HRQOL to anxiety symptoms, it was significant for the eight SF-36 domains and its two components, being negative and strong in the \"Mental Health\" domain and in the Mental Component, and moderate in the other domains. Anxiety was negatively, significantly and moderately correlated to all three AQUAREL domains. The correlation of depression to HRQOL, was significant in the eight SF-36 domains and its two components, negative and strong in the \"Mental Health\" domain and moderately strong in four Mental Component domains. Depression was negatively, significantly and moderately correlated to all three AQUAREL domains. Conclusion: Patients had lower HRQOL in the domains which evaluated how do physical conditions interfere in their daily lives. Women, patients with no partners and more anxiety and depression symptoms had worse results in the evaluation.
12

Radio frequency power absorption in a human model with pacemakers in MRI

Abrishamkar, Houman 13 November 2009 (has links)
The interactions of the radio frequency (RF) fields in magnetic resonance imaging (MRI) with a human body model are investigated. In particular, the interactions of these fields with an implanted pacemaker are studied. The specific absorption rate (SAR) levels in a heterogeneous body model are evaluated in two different birdcage coils - a resonant and a non-resonant coil - at a magnetic field of 1.5 T. The enhancement of the SAR due to an implanted cardiac pacemaker and the effect of the conductivity of the pacemaker lead on the SAR levels are investigated. The finite difference time domain (FDTD) technique is used to model these interactions. The SAR levels are found to be low in the heart region, and thus the SAR enhancement due to the pacemaker lead is relatively low. Modeling of the pacemaker leads as perfect conductors results in greater SAR enhancements than those produced by actual conductive leads.
13

Optimal pacing with an implantable pO₂ sensor /

Holmström, Nils Brage, January 1900 (has links) (PDF)
Diss. (sammanfattning) Stockholm : Tekn. högsk. / Härtill 4 uppsatser.
14

Implantable devices in heart failure : studies on biventricular pacing and continuous hemodynamic monitoring /

Braunschweig, Frieder, January 2002 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2002. / Härtill 6 uppsatser.
15

Aspectos tecnicos da cateterização do seio coronariano baseado no componente atrial do eletrograma intracavitario durante o procedimento de implante de marcapasso biventricular / Technical aspects of coronary sinus catheterization based on the atrial component of the intracavitary eletrogram and radiological anatomy during implantation procedure of a biventricular pacemaker

Souza, Fernando Sergio Oliva de 17 April 2008 (has links)
Orientador: Orlando Petrucci Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T10:51:42Z (GMT). No. of bitstreams: 1 Souza_FernandoSergioOlivade_D.pdf: 1025341 bytes, checksum: 15ba5e4c6177129ac03b697eb1f59cb9 (MD5) Previous issue date: 2008 / Resumo: A estimulação elétrica biventricular apresenta bons resultados no tratamento da insuficiência cardíaca congestiva refratária em portadores de cardiomiopatia dilatada com distúrbios de condução interventricular. OBJETIVO: Apresentar proposição utilizando técnica original simplificada para o implante de eletrodo de estimulação ventricular esquerda epicárdica, baseado na anatomia radiológica e no eletrograma intracavitário,enfatizando o componente atrial, demonstrando o resultado, complicações, ressaltando tempo total de utilização de fluoroscópio. CASUÍSTICA E MÉTODO: De Outubro de 2001 a Março de 2007 foram realizados 234 implantes de marca-passo biventricular em pacientes previamente selecionados, utilizando-se anatomia radiológica e observação de eletrograma intracavitário, dando-se prioridade ao componente atrial, demonstrando a taxa de sucesso, complicações e tempo total de utilização de radioscopia. RESULTADOS: O implante do sistema, utilizando-se a estimulação do ventrículo esquerdo via seio coronariano não foi possível em 19(8,1%) pacientes. Em 30(12,8%) pacientes foram observadas dificuldades na canulação do óstio coronário e em 52(22%) pacientes observaram-se dificuldades de progressão do eletrodo através do seio coronário. O tempo médio de utilização de radioscopia foi 18,69(±15,2) min. CONCLUSÃO: A utilização da técnica simplificada para cateterização do seio coronário sem utilização de bainha, baseada na anatomia radiológica e no eletrograma intracavitário, enfatizando o componente atrial, no tratamento de portadores de cardiomiopatia dilatada avançada, pela terapia de ressincronização cardíaca, demonstrou resultado satisfatório, índice de complicações pequeno, e baixa exposição do operador a radiação ionizante / Abstract: Biventricular pacing has present good results in treatment of congestive cardiac heart failure in patients with dilated miocardyopathy and interventricular conduction disturbance. PURPOSE: to present a proposal of using a original simplified technique for left epicardial ventricular lead stimulation, based on the radiological imaging of the anatomy and intracavitary electrogram, emphasizing the atrial component, showing the results, complications, highlighting the total fluoro time. METHODS: From October, 2001 up to March, 2007, 234 biventricular pacemaker implantations were performed in previously selected patients, using radiological anatomy and observation of the intracavitary electrogram, focusing on the atrial component, and showing the success rate, complications and total time of radioscopy utilization. RESULTS: The implantation of the system using left ventricular pacing via coronary sinus was not possible in 19(8,1%) patients. Difficulties on the cannulation of the coronary ostium were felt in 30(12,8%) patients and difficulties of lead advancement through the coronary sinus were felt in 52(22%) patients. The mean time of radioscopy utilization was 18.69(±15,2) min. CONCLUSION: the use of a simplified technique for coronary sinus cannulation without the aid of a sheath, based on the radiological imaging of the anatomy and intracavitary electrogram, emphasizing the atrial component, for the treatment of advanced dilated cardiomyopathy patients with cardiac resynchronization therapy, has shown satisfactory results, low incidence of complications, and low exposure of the operator to ionizing radiation / Doutorado / Cirurgia / Doutor em Cirurgia
16

Qualidade e capacidade diagnóstica da imagem de ressonância magnética cardíaca de 1,5 Tesla em pacientes com cardioversor desfibrilador implantável condicional / Quality and diagnostic capacity of the 1.5 Tesla magnetic resonance imaging in patients with conditional implantable cardioverter defibrillator

Andrade, Veridiana Silva de 28 May 2019 (has links)
Introdução: A realização do exame de ressonância magnética (RM), classicamente contraindicada aos portadores de dispositivo cardíaco eletrônico implantável (DCEI), passou a ser factível com a introdução dos recentes dispositivos condicionais para RM. Estes demonstraram superior grau de segurança na realização da RM, mas pouco se sabe sobre a qualidade e a capacidade diagnóstica das imagens obtidas no exame. Estas podem ser distorcidas pela presença do DCEI, sobretudo no que se refere ao cardioversor desfibrilador implantável (CDI), cuja quantidade de material ferromagnético é relevante. Objetivo: avaliar a qualidade e a capacidade diagnóstica da imagem de da RM cardíaca de 1,5 Tesla em portadores de CDI condicional. Método: Estudo piloto incluindo portadores de CDI condicional submetidos a RMC prévia (RMC1). Todos os pacientes realizaram exame de RMC pós-implante (RMC2), com protocolo específico de sequências de pulso utilizadas para cineressonância, realce tardio, perfusão miocárdica, mapa T1, mapa de fluxo, avaliação anatômica e de edema miocárdico. Todos foram submetidos à avaliação eletrônica do CDI, pré e pós RMC2, que constou de: medida do limiar de estimulação e sensibilidade, da impedância dos cabos-eletrodo e de choque, assim como da carga da bateria. Três especialistas avaliaram a qualidade das imagens de RMC, pré e pós-implante do CDI, que foram pontuadas por Escala de Likert. Esta gradua de 1 a 5 o impacto do artefato de imagem e a capacidade diagnóstica do exame. Para as imagens obtidas por múltiplos cortes a mesma pontuação foi utilizada para cada segmento do VE (segmentação da American Heart Association - AHA). A capacidade diagnóstica foi expressa, em percentual, pela taxa diagnóstica (sendo considerada diagnóstica pontuação maior ou igual a 3). Resultados: Foram estudados 22 pacientes submetidos a implante CDI condicional no período de agosto/2016 a abril/2018. Todas as imagens da RMC1 tiveram alta pontuação (3 a 5, m= 4,7) na escala de Likert. Por outro lado, em todos os exames da RMC2 ocorreram artefatos de suscetibilidade, sendo que as paredes anterior e lateral do VE foram mais afetadas. A pontuação média segmentar e respectivas taxas de imagens diagnósticas foram: 3,1 pontos e 82,32% para CINE SSFP; 1,74 e 27,80% para RT; 2,08 e 30,4% para perfusão miocárdica. As taxas de imagens diagnósticas obtidas nas aquisições por corte único foram: 0% para o mapa T1; 77,3% para avaliação anatômica (double e triple anatômico); 68,2% mapa de fluxo e 9,0% para avaliação do edema. Conclusão: Em portadores de CDI condicional, a qualidade das imagens e a capacidade diagnóstica do exame de RMC estão comprometidas por artefatos de suscetibilidade, presentes, sobretudo, nas paredes anterior e lateral de VE. Em particular a técnica de realce tardio, uma das mais importantes na RMC para diagnóstico de cardiomiopatias, demonstrou reduzida taxa diagnóstica, apontando a necessidade de novas técnicas para a detecção de fibrose/lesão miocárdica pela RMC. De forma geral, esses achados sugerem que é necessário realizar investigações adicionais, visando otimizar qualidade de imagem e capacidade diagnóstica da RMC nos portadores de CDI condicional / Introduction: Magnetic resonance imaging (MRI), which is classically contraindicated in patients with cardiac implantable electronic device (CIED), became feasible with the introduction of the recent MRI conditional devices. These have been proven to be safer, but little is known about the quality and diagnostic capacity of the acquired images, which can be distorted by the presence of CIED, especially with regard to the implantable cardioverter defibrillator (ICD), whose quantity of ferromagnetic material is relevant. Objective: to evaluate the quality and diagnostic value of the images acquired by cardiac MR in patients with conditional ICD. Method: Pilot study of patients with MR conditional ICD who were submitted to previous CMR (CMR1). All patients underwent an another CMR after ICD implantation (CMR2), under specific protocol of pulse sequences used for cine-resonance, late enhancement, myocardial perfusion, T1 mapping, anatomic and myocardial edema evaluation, and flow map. All patients underwent ICD electronic interrogations, immediate pre and post CMR2 measurements of battery voltage, capture thresholds, sensing, lead and shock impedance. Three specialists evaluated the quality of CMR images, pre and post implantation of ICD, which were scored by the Likert Scale. This graded measure from 1 to 5 the impact of the imaging artifact and the diagnostic ability of the examination. For the images acquired by multiple slices the same score was used for each left ventricule (LV) segment (American Heart Association - AHA criteria). Results: We studied 22 patients submitted to MR conditional ICD implantation. CMR1 had a high score (3 to 5, m = 4.7) on the Likert scale. On the other hand, in all CMR2 exams, there were artifacts of susceptibility, and the anterior and lateral LV walls were more affected. The mean segmental score and respective diagnostic image rates were: 3.1 points and 82.32% for Cine SSFP; 1.74 and 27.80% for LGE; 2.08 and 30,4% for myocardial perfusion. The rates of diagnostic images obtained in the single slice acquisition were 0% for T1 mapping; 77.3% for anatomical evaluation (double and triple anatomic); 68.2% for flow map and 9.0% for myocardial edema evaluation. Conclusion: In patients with MR conditional ICD, the quality of the images and the diagnostic capacity of the CMR examination are compromised by susceptibility artifacts, present mainly in the anterior and lateral LV walls. These findings suggest that further research is needed to optimize image quality and diagnostic capacity of CMR in patients with MR conditional ICD
17

Avaliação das funções executivas em portadores de fibrilação atrial e insuficiência cardíaca / Evaluation of executive function in carriers of atrial fibrillation and heart failure

Vaughan, Renata Aparecida da Rocha 13 November 2017 (has links)
Introdução: A Insuficiência Cardíaca (IC) e a Fibrilação Atrial (FA) são patologias frequentes na população idosa e estão associadas a alterações da esfera cognitiva. No entanto, suas consequências sobre as funções executivas, responsáveis pela resolução de problemas, ainda não estão totalmente esclarecidas. Objetivo: investigar as características do funcionamento executivo em pacientes com FA e/ou IC e identificar se tal funcionamento é equiparável ao de um grupo controle. Método: Estudo observacional, de coorte transversal, realizado em hospital de atenção terciária em cardiologia que avaliou 191 sujeitos, com uma média de 69,1 anos de idade (mín.: 60; Max.: 82) distribuídos em cinco grupos distintos: com FA, com IC associada à FA, com IC e controles (com e sem marca-passo artificial MP). Os grupos foram pareados por faixa etária e variáveis sócio-demográficas, submetidos à avaliação neuropsicológica e a análise estatística envolveu testes não paramétricos (Kruskall-Wallys e Mann-Whitney), qui-quadrado de Pearson e teste exato de Fisher. Resultados: Nos indivíduos com FA comparados aos controles sem MP, observamos diferenças estatisticamente significativas relacionadas a memória operacional (p = 0,034), a memória tardia (p = 0,015), a memória semântica e fluência verbal (p < 0,001), a compreensão (p < 0,001), ao planejamento e a habilidade visuoespacial (p < 0,001), a percepção visual e a linguagem (p< 0,001) e ao controle inibitório e a velocidade de processamento, nas três fases do instrumento (p < 0,008; p < 0,004; p < 0,002). Já nos indivíduos com FA associada à IC, as diferenças observadas envolveram: a memória semântica e a fluência verbal (p = 0,05), o planejamento e a habilidade visuoespacial (p < 0,001), a percepção visual e a linguagem (p < 0,001) e o controle inibitório e a velocidade de processamento (p = 0,002; p < 0,001; p = 0,145, respectivamente). Os sujeitos com IC demonstraram o mesmo desempenho do grupo de indivíduos com FA e IC, com diferenças relacionadas às mesmas funções, exceto na primeira fase do instrumento que avaliou controle inibitório e a velocidade de processamento (p < 0,001). Quanto à funcionalidade, não observamos diferença estatisticamente significativa entre os grupos. Conclusões: O funcionamento executivo de indivíduos com FA ou IC não é equiparável ao de indivíduos sem essas doenças. A FA, de uma perspectiva neuropsicológica, intensifica o prejuízo das FE e também da memória / Introduction: Heart Failure (HF) and Atrial Fibrillation (AF) are frequent pathologies in the elderly population and are associated with cognitive disorders. However, its consequences on executive functions, which are responsible for solving problems, have not yet been fully clarified. Objective: to investigate the characteristics of executive functioning in patients with AF and/or HF and to identify if such functioning is comparable to that of a control group. Methods: A cross-sectional observational study performed in a tertiary care hospital in cardiology, which evaluated 191 subjects with a mean age of 69.1 years (min.: 60, Max.: 82) distributed in five different groups: AF, with HF associated with AF, with HF and controls (with and without pacemaker). The groups were matched by age group and socio-demographic variables, submitted to neuropsychological evaluation and statistical analysis involved non-parametric tests (Kruskall-Wallys and Mann-Whitney), Pearson\'s chi-square and Fisher\'s exact test. Results: In subjects with AF compared to non-pacemaker controls, we observed statistically significant differences related to operational memory (p = 0.034), late memory (p = 0.015), semantic memory and verbal fluency (p < 0.001), comprehension P < 0.001), visuospatial planning and ability (p < 0.001), visual perception and language (p < 0.001) and inhibitory control and processing speed in the three phases of the instrument (p < 0.008; p < 0.004, p < 0.002). In subjects with HF associated with HF, the observed differences involved: semantic memory and verbal fluency (p = 0.05), planning and visuospatial ability (p < 0.001), visual perception and language (p < 0.001) and inhibitory control and processing speed (p = 0.002, p < 0.001, p = 0.145, respectively). Subjects with HF demonstrated the same performance of the group of individuals with AF and HF, with differences related to the same functions, except in the first phase of the instrument that evaluated inhibitory control and processing speed (p < 0.001). Regarding functionality, we did not observe a statistically significant difference between groups. Conclusions: The executive functioning of individuals with AF or IC is not comparable to that of individuals without these diseases. AF, from a neuropsychological perspective, intensifies the damage of FE and memory
18

Estudo da segurança e da estabilidade do implante de cabo-eletrodo atrial direito pela via epidemiocárdiaca através do seio transverso em modelo animal suíno / Evaluation of safety and stability of right atrial lead implantation by epimyocardial access through the transverse sinus in a swine model

Bueno, Sávia Christina Pereira 13 June 2013 (has links)
Introdução: Embora o implante de marcapasso atrioventricular pela via endovenosa seja considerado o estado da arte, situações clínicas e técnicas que podem impossibilitar o implante transvenoso de cabos-eletrodos têm sido cada vez mais frequentes, tornando-se necessária a proposição de abordagens cirúrgicas alternativas. Objetivos: O presente estudo visou o implante de marcapasso atrioventricular utilizando nova técnica para implante de cabo-eletrodo atrial no átrio direito, com o objetivo de avaliar no período intra-operatório e nos 30 primeiros dias de seguimento: a segurança e a reprodutibilidade do procedimento cirúrgico; a taxa de deslocamento dos cabos-eletrodos; as condições de estimulação e sensibilidade; as alterações morfológicas na cavidade pericárdica e as alterações histopatológicas epimiocárdicas. Métodos: Sob anestesia geral, foram operados 10 porcos adultos da raça Large White. Os cabos-eletrodos foram implantados, sob visão direta, no ventrículo esquerdo e no átrio direito, pelo seio transverso, através de toracotomia anterolateral esquerda. As condições de estimulação e de sensibilidade para os cabos-eletrodos atrial e ventricular, nas configurações unipolar e bipolar, foram avaliadas no intra-operatório, pós-operatório imediato, no 7º e 30º dias de pós-operatório. Ao final do estudo, os animais foram reoperados por toracotomia longitudinal mediana para observação das aderências pericárdicas e análise das condições histopatológicas da junção entre o cabo-eletrodo e o epimiocárdico. Resultados: Todos os animais permaneceram vivos até o último dia do estudo, não tendo ocorrido complicações intra-operatórias graves. As condições de estimulação e sensibilidade para os cabos-eletrodos atriais e ventriculares, nas configurações unipolar e bipolar, mantiveram-se estáveis ao longo do estudo e apresentaram comportamento semelhante. Notou-se aumento progressivo dos limiares atriais, variando de 0,50 ± 0,38 a 1,86 ± 1,31 volts nos períodos intra-operatório e 30o pós-operatório, respectivamente. Comportamento semelhante foi observado para os limiares ventriculares, que variaram de 0,43 ± 0,23 volts, no intra-operatório, a 1,22 ± 0,49 volts, no 30o pós-operatório. As medidas de impedância atrial e ventricular apresentaram uma discreta queda ao longo do tempo, sendo que a impedância atrial variou de 486,80 ± 126,35 a 385,0 ± 80,52 Ohms no período intra-operatório e 30o pós-operatório, respectivamente. A impedância ventricular variou de 700,40 ± 203,67 Ohms, no intra-operatório, a 409,30 ± 58,96 Ohms, no 30o pós-operatório. A sensibilidade, tanto em átrio quanto em ventrículo, mostrou-se estável a partir do pós-operatório imediato. A inspeção da cavidade pericárdica mostrou aderências em todos os animais e em todas as regiões avaliadas, não sendo observados derrame ou constrição pericárdica. A análise microscópica mostrou que o contato com os cabos-eletrodos provocou espessamento do epimiocárdio no átrio direito, ventrículo esquerdo e na artéria pulmonar. A cicatriz formada na junção entre o cabo-eletrodo e o epimiocárdio atrial foi semelhante à formada na região do implante dos cabos-eletrodos ventriculares. Conclusões: O implante do cabo-eletrodo atrial direito pelo seio transverso foi seguro e reprodutível. A efetividade do procedimento foi confirmada pelas condições estáveis de estimulação e de sensibilidade durante o período de seguimento pós-operatório. A única alteração morfológica encontrada na cavidade pericárdica foi a formação de aderências. Ocorreu adequada cicatrização na junção entre o cabo eletrodo e o epimiocárdio atrial / Introduction: Although transvenous access for atrioventricular pacemaker implantation is considered the state of the art, clinical and technical situations that may impede transvenous leads implantation have become increasingly common, making it necessary the proposal of new surgical approaches. Objectives: The present study was design to perform the implant of atrioventricular pacemaker using a new technique for placement of the atrial lead in the right atrium, aiming to evaluate in the intraoperative period and during the first 30 days of follow-up: the safety and reproducibility of the surgical procedure; lead dislodgment rate; conditions of pacing and sensing; morphological changes in the pericardium, as well as, histopathological changes in the epimyocardium. Methods: A total of 10 Large White adult pigs underwent pacemaker implantation under general anesthesia. By using an anterolateral thoracotomy, leads were implanted under visual guidance in the left ventricle and in the right atrium through the transverse sinus. Pacing and sensing parameters, in unipolar and bipolar modes, were obtained during the intraoperative and immediate postoperative period and on the 7th and the 30th postoperative day. At the end of the study, all animals underwent reoperation by thoracotomy through a median longitudinal sternotomy for evaluation of pericardial adhesions and histopathological analysis of the junction between the lead and epimyocardial wall. Results: All animals were alive until the end of the study and there were no serious intraoperative complications. Pacing and sensing parameters for atrial and ventricular leads in both unipolar and bipolar modes remain stable throughout the study and showed similar performance. We observed a progressive increase in atrial thresholds, ranging from 0.50 ± 0.38 to 1.86 ± 1.31 volts, during the intraoperative and on the 30-day postoperative, respectively. Similar result was observed for ventricular thresholds, which ranged from 0.43 ± 0.23 volts, intraoperatively, to 1.22 ± 0.49 volts on the 30-day postoperative. Atrial and ventricular impedance measurements decreased slightly over time, and the atrial impedance ranged from 486.80 ± 126.35 to 385.0 ± 80.52 Ohms during the intraoperative and on the 30-day postoperative, respectively. Ventricular impedance ranged from 700.40 ± 203.67 Ohms, intraoperatively, to 409.30 ± 58.96 Ohms, on the 30-day postoperative. Both atrial and ventricular sensing measurements remain stable since the immediate postoperative period. Pericardial adhesions were found in all animals and in all studied regions. There was no noticeable pericardial effusion or myocardial constriction. Microscopic analysis showed that contact with the electrode had caused thickening of the right atrium, left ventricle and pulmonary artery. Similar scar formation was found at the interface between atrial lead and epimyocardial, such as ventricular lead and epimyocardial. Conclusion: Implantation of the right atrial lead through the transverse sinus was safe and reproducible. The effectiveness of the procedure was confirmed by stable conditions of pacing and sensing parameters throughout the postoperative follow-up. Pericardial adhesion was the only change found in the pericardial morphology. There was adequate scar formation between the interface of atrial lead and the epimyocardial
19

Avaliação das funções executivas em portadores de fibrilação atrial e insuficiência cardíaca / Evaluation of executive function in carriers of atrial fibrillation and heart failure

Renata Aparecida da Rocha Vaughan 13 November 2017 (has links)
Introdução: A Insuficiência Cardíaca (IC) e a Fibrilação Atrial (FA) são patologias frequentes na população idosa e estão associadas a alterações da esfera cognitiva. No entanto, suas consequências sobre as funções executivas, responsáveis pela resolução de problemas, ainda não estão totalmente esclarecidas. Objetivo: investigar as características do funcionamento executivo em pacientes com FA e/ou IC e identificar se tal funcionamento é equiparável ao de um grupo controle. Método: Estudo observacional, de coorte transversal, realizado em hospital de atenção terciária em cardiologia que avaliou 191 sujeitos, com uma média de 69,1 anos de idade (mín.: 60; Max.: 82) distribuídos em cinco grupos distintos: com FA, com IC associada à FA, com IC e controles (com e sem marca-passo artificial MP). Os grupos foram pareados por faixa etária e variáveis sócio-demográficas, submetidos à avaliação neuropsicológica e a análise estatística envolveu testes não paramétricos (Kruskall-Wallys e Mann-Whitney), qui-quadrado de Pearson e teste exato de Fisher. Resultados: Nos indivíduos com FA comparados aos controles sem MP, observamos diferenças estatisticamente significativas relacionadas a memória operacional (p = 0,034), a memória tardia (p = 0,015), a memória semântica e fluência verbal (p < 0,001), a compreensão (p < 0,001), ao planejamento e a habilidade visuoespacial (p < 0,001), a percepção visual e a linguagem (p< 0,001) e ao controle inibitório e a velocidade de processamento, nas três fases do instrumento (p < 0,008; p < 0,004; p < 0,002). Já nos indivíduos com FA associada à IC, as diferenças observadas envolveram: a memória semântica e a fluência verbal (p = 0,05), o planejamento e a habilidade visuoespacial (p < 0,001), a percepção visual e a linguagem (p < 0,001) e o controle inibitório e a velocidade de processamento (p = 0,002; p < 0,001; p = 0,145, respectivamente). Os sujeitos com IC demonstraram o mesmo desempenho do grupo de indivíduos com FA e IC, com diferenças relacionadas às mesmas funções, exceto na primeira fase do instrumento que avaliou controle inibitório e a velocidade de processamento (p < 0,001). Quanto à funcionalidade, não observamos diferença estatisticamente significativa entre os grupos. Conclusões: O funcionamento executivo de indivíduos com FA ou IC não é equiparável ao de indivíduos sem essas doenças. A FA, de uma perspectiva neuropsicológica, intensifica o prejuízo das FE e também da memória / Introduction: Heart Failure (HF) and Atrial Fibrillation (AF) are frequent pathologies in the elderly population and are associated with cognitive disorders. However, its consequences on executive functions, which are responsible for solving problems, have not yet been fully clarified. Objective: to investigate the characteristics of executive functioning in patients with AF and/or HF and to identify if such functioning is comparable to that of a control group. Methods: A cross-sectional observational study performed in a tertiary care hospital in cardiology, which evaluated 191 subjects with a mean age of 69.1 years (min.: 60, Max.: 82) distributed in five different groups: AF, with HF associated with AF, with HF and controls (with and without pacemaker). The groups were matched by age group and socio-demographic variables, submitted to neuropsychological evaluation and statistical analysis involved non-parametric tests (Kruskall-Wallys and Mann-Whitney), Pearson\'s chi-square and Fisher\'s exact test. Results: In subjects with AF compared to non-pacemaker controls, we observed statistically significant differences related to operational memory (p = 0.034), late memory (p = 0.015), semantic memory and verbal fluency (p < 0.001), comprehension P < 0.001), visuospatial planning and ability (p < 0.001), visual perception and language (p < 0.001) and inhibitory control and processing speed in the three phases of the instrument (p < 0.008; p < 0.004, p < 0.002). In subjects with HF associated with HF, the observed differences involved: semantic memory and verbal fluency (p = 0.05), planning and visuospatial ability (p < 0.001), visual perception and language (p < 0.001) and inhibitory control and processing speed (p = 0.002, p < 0.001, p = 0.145, respectively). Subjects with HF demonstrated the same performance of the group of individuals with AF and HF, with differences related to the same functions, except in the first phase of the instrument that evaluated inhibitory control and processing speed (p < 0.001). Regarding functionality, we did not observe a statistically significant difference between groups. Conclusions: The executive functioning of individuals with AF or IC is not comparable to that of individuals without these diseases. AF, from a neuropsychological perspective, intensifies the damage of FE and memory
20

Estudo da segurança e da estabilidade do implante de cabo-eletrodo atrial direito pela via epidemiocárdiaca através do seio transverso em modelo animal suíno / Evaluation of safety and stability of right atrial lead implantation by epimyocardial access through the transverse sinus in a swine model

Sávia Christina Pereira Bueno 13 June 2013 (has links)
Introdução: Embora o implante de marcapasso atrioventricular pela via endovenosa seja considerado o estado da arte, situações clínicas e técnicas que podem impossibilitar o implante transvenoso de cabos-eletrodos têm sido cada vez mais frequentes, tornando-se necessária a proposição de abordagens cirúrgicas alternativas. Objetivos: O presente estudo visou o implante de marcapasso atrioventricular utilizando nova técnica para implante de cabo-eletrodo atrial no átrio direito, com o objetivo de avaliar no período intra-operatório e nos 30 primeiros dias de seguimento: a segurança e a reprodutibilidade do procedimento cirúrgico; a taxa de deslocamento dos cabos-eletrodos; as condições de estimulação e sensibilidade; as alterações morfológicas na cavidade pericárdica e as alterações histopatológicas epimiocárdicas. Métodos: Sob anestesia geral, foram operados 10 porcos adultos da raça Large White. Os cabos-eletrodos foram implantados, sob visão direta, no ventrículo esquerdo e no átrio direito, pelo seio transverso, através de toracotomia anterolateral esquerda. As condições de estimulação e de sensibilidade para os cabos-eletrodos atrial e ventricular, nas configurações unipolar e bipolar, foram avaliadas no intra-operatório, pós-operatório imediato, no 7º e 30º dias de pós-operatório. Ao final do estudo, os animais foram reoperados por toracotomia longitudinal mediana para observação das aderências pericárdicas e análise das condições histopatológicas da junção entre o cabo-eletrodo e o epimiocárdico. Resultados: Todos os animais permaneceram vivos até o último dia do estudo, não tendo ocorrido complicações intra-operatórias graves. As condições de estimulação e sensibilidade para os cabos-eletrodos atriais e ventriculares, nas configurações unipolar e bipolar, mantiveram-se estáveis ao longo do estudo e apresentaram comportamento semelhante. Notou-se aumento progressivo dos limiares atriais, variando de 0,50 ± 0,38 a 1,86 ± 1,31 volts nos períodos intra-operatório e 30o pós-operatório, respectivamente. Comportamento semelhante foi observado para os limiares ventriculares, que variaram de 0,43 ± 0,23 volts, no intra-operatório, a 1,22 ± 0,49 volts, no 30o pós-operatório. As medidas de impedância atrial e ventricular apresentaram uma discreta queda ao longo do tempo, sendo que a impedância atrial variou de 486,80 ± 126,35 a 385,0 ± 80,52 Ohms no período intra-operatório e 30o pós-operatório, respectivamente. A impedância ventricular variou de 700,40 ± 203,67 Ohms, no intra-operatório, a 409,30 ± 58,96 Ohms, no 30o pós-operatório. A sensibilidade, tanto em átrio quanto em ventrículo, mostrou-se estável a partir do pós-operatório imediato. A inspeção da cavidade pericárdica mostrou aderências em todos os animais e em todas as regiões avaliadas, não sendo observados derrame ou constrição pericárdica. A análise microscópica mostrou que o contato com os cabos-eletrodos provocou espessamento do epimiocárdio no átrio direito, ventrículo esquerdo e na artéria pulmonar. A cicatriz formada na junção entre o cabo-eletrodo e o epimiocárdio atrial foi semelhante à formada na região do implante dos cabos-eletrodos ventriculares. Conclusões: O implante do cabo-eletrodo atrial direito pelo seio transverso foi seguro e reprodutível. A efetividade do procedimento foi confirmada pelas condições estáveis de estimulação e de sensibilidade durante o período de seguimento pós-operatório. A única alteração morfológica encontrada na cavidade pericárdica foi a formação de aderências. Ocorreu adequada cicatrização na junção entre o cabo eletrodo e o epimiocárdio atrial / Introduction: Although transvenous access for atrioventricular pacemaker implantation is considered the state of the art, clinical and technical situations that may impede transvenous leads implantation have become increasingly common, making it necessary the proposal of new surgical approaches. Objectives: The present study was design to perform the implant of atrioventricular pacemaker using a new technique for placement of the atrial lead in the right atrium, aiming to evaluate in the intraoperative period and during the first 30 days of follow-up: the safety and reproducibility of the surgical procedure; lead dislodgment rate; conditions of pacing and sensing; morphological changes in the pericardium, as well as, histopathological changes in the epimyocardium. Methods: A total of 10 Large White adult pigs underwent pacemaker implantation under general anesthesia. By using an anterolateral thoracotomy, leads were implanted under visual guidance in the left ventricle and in the right atrium through the transverse sinus. Pacing and sensing parameters, in unipolar and bipolar modes, were obtained during the intraoperative and immediate postoperative period and on the 7th and the 30th postoperative day. At the end of the study, all animals underwent reoperation by thoracotomy through a median longitudinal sternotomy for evaluation of pericardial adhesions and histopathological analysis of the junction between the lead and epimyocardial wall. Results: All animals were alive until the end of the study and there were no serious intraoperative complications. Pacing and sensing parameters for atrial and ventricular leads in both unipolar and bipolar modes remain stable throughout the study and showed similar performance. We observed a progressive increase in atrial thresholds, ranging from 0.50 ± 0.38 to 1.86 ± 1.31 volts, during the intraoperative and on the 30-day postoperative, respectively. Similar result was observed for ventricular thresholds, which ranged from 0.43 ± 0.23 volts, intraoperatively, to 1.22 ± 0.49 volts on the 30-day postoperative. Atrial and ventricular impedance measurements decreased slightly over time, and the atrial impedance ranged from 486.80 ± 126.35 to 385.0 ± 80.52 Ohms during the intraoperative and on the 30-day postoperative, respectively. Ventricular impedance ranged from 700.40 ± 203.67 Ohms, intraoperatively, to 409.30 ± 58.96 Ohms, on the 30-day postoperative. Both atrial and ventricular sensing measurements remain stable since the immediate postoperative period. Pericardial adhesions were found in all animals and in all studied regions. There was no noticeable pericardial effusion or myocardial constriction. Microscopic analysis showed that contact with the electrode had caused thickening of the right atrium, left ventricle and pulmonary artery. Similar scar formation was found at the interface between atrial lead and epimyocardial, such as ventricular lead and epimyocardial. Conclusion: Implantation of the right atrial lead through the transverse sinus was safe and reproducible. The effectiveness of the procedure was confirmed by stable conditions of pacing and sensing parameters throughout the postoperative follow-up. Pericardial adhesion was the only change found in the pericardial morphology. There was adequate scar formation between the interface of atrial lead and the epimyocardial

Page generated in 0.0564 seconds