Spelling suggestions: "subject:"apressão positiva"" "subject:"epressão positiva""
81 |
Efeito da fisioterapia respiratória precoce em pacientes no pós-operatório imediato de cirurgia de revascularização do miocárdio e seu impacto clínico / Early manual hyperinflation physiotherapy improves oxygenation parameters after myocardial revascularization : a randomized clinical trialBlattner, Clarissa Netto January 2008 (has links)
Objetivo: Verificar a eficácia da fisioterapia respiratória precoce, através da hiperinsuflação manual (HM) associada à pressão expiratória positiva final (PEEP) no pós-operatório de pacientes submetidos à cirurgia de revascularização do miocárdio (CRM). Método: Ensaio clínico randomizado. Participantes: Cinqüenta e cinco pacientes foram incluídos no estudo, onde o grupo intervenção foi submetido à técnica fisioterapêutica logo no pósoperatório imediato e o grupo controle recebeu a rotina assistencial do serviço. Foram avaliados parâmetros de oxigenação, através da gasometria arterial, tempo de extubação, complacência pulmonar e presença de complicações respiratórias pós-operatórias. Resultados: Houve melhora significativa no grupo intervenção quando comparado ao controle nos seguintes parâmetros: oxigenação (PaO2 93,4±5,51mmHg x 81,7±2,25mmHg – p<0,001), tempo de extubação (295,4±41,7min x 371,5±130,1min – p=0,005) e complacência estática (60,3±4,43ml/cmH2O x 51,8±3,22ml/cmH2O – p<0,001). Conclusão: O grupo que foi submetido à fisioterapia precoce com hiperinsuflação manual apresentou melhora significativa em termos de oxigenação, complacência estática e redução do tempo de permanência em ventilação mecânica, quando comparado ao grupo controle. A incidência de complicações respiratórias pós-operatórias foi similar nos dois grupos. / Question: How does immediate postoperative respiratory physiotherapy affect clinical parameters, oxygenation and static compliance after myocardial revascularization (MR), and what impact does it have on clinical outcome, pulmonary complications and intubation time? Design: Randomized clinical trial. Participants: Fifty-five patients scheduled for elective myocardial revascularization. Intervention: A physiotherapy technique was used for the intervention group immediately after surgery; the control group received the service’s routine care. Outcome measures: Oxygenation parameters were evaluated by means of arterial blood gases, extubation time, lung compliance and postoperative respiratory complications. Results: Improvement in the intervention group was significantly greater than in the control group according to the following parameters: oxygenation (PaO2 93.4±5.51 mmHg x 81.7±2.25 mmHg; p<0.001), extubation time (295.4±41.7 min x 371.5±130.1min; p=0.005) and static compliance (60.3±4.43 ml/cmH2O x 51.8±3.22 ml/cmH2O; p<0.001). Conclusion: The group that received early manual hyperinflation physiotherapy had significantly better oxygenation and static compliance and shorter mechanical ventilation times than the control group. The incidence of postoperative respiratory complications was similar in the two groups.
|
82 |
Avaliação ecocardiográfica e da capacidade funcional por ensaio clínico randomizado dos efeitos agudos de dois modos de ventilação não-invasiva nasal na insuficiência cardíaca compensadaMundstock, Lorena Contreras January 2008 (has links)
Introdução: Os efeitos agudos da ventilação não invasiva (VNI), comparando os modos continuous positive airway pressure (CPAP) versus bilevel positive airway pressure (BiPAP) devem ser melhor verificados em pacientes insuficiência cardíaca (IC) crônica. Objetivo: avaliar os efeitos agudos da VNI em pacientes com IC na resposta hemodinâmica da função cardíaca por ecocardiografia com Doppler Tissular e na avaliação da capacidade funcional através do teste de caminhada de 6 minutos (TC6min), utilizando modo CPAP versus BiPAP. Métodos vinte e seis pacientes portadores de insuficiência cardíaca selecionados de ambulatórios de cardiologia de hospitais-escola de Porto Alegre. Os pacientes foram randomizados para receber VNI pelos modos CPAP ou BiPAP durante 60 minutos. Foram realizados TC6min e ecocardiograma antes e após o uso da VNI. No modo CPAP foi utilizada pressão de 8 cmH2O, e no BiPAP foram 8 cmH2O de pressão inspiratória e 4 cmH2O de pressão expiratória. Resultados: o tempo de relaxamento isovolumétrico (TRIV) diminuiu após uso do CPAP (pré = 104,7±18,9 mseg versus pós = 60,48±19,2 mseg; p<0,05) e a fração de encurtamento (FS) diminuiu em ambos os modos (pré = 25,9±1,4% versus pós = 23,15±1,02%, P < 0,05). Entre os pacientes com fração de ejeção do ventrículo esquerdo (FEVE) >= 50%, houve aumento do diâmetro sistólico final do VE (DSFVE) (pré = 37,27±2,84mm versus pós = 41,8±2,77mm; p<0,05) e diminuição da FEVE (pré = 61,9±2,6% versus pós = 53,32±2,9%). A capacidade funcional não foi alterada com o uso da VMNI. Conclusão: O CPAP alterou significativamente o TRIV. A FEVE preservada influenciou os resultados da função contrátil do VE. A VNI não provocou alterações significativas sobre a capacidade funcional. / Introdução: The noninvasive ventilation (NIV) acute effects da ventilação não invasiva by comparing continuous positive airway pressure (CPAP) versus bilevel positive airway pressure (BiPAP) should be more investigated in patients with chronic heart failure (CHF). Objective: evaluate the acute effects of NIV in patients with heart failure (HF) in the hemodynamic response of the cardiac function through echocardiography with Tissue Doppler and in the assessment of functional capability through the 6-minute walk test (6MWT), using CPAP vs. BiPAP modes. Methods: twenty-six patients with HF recruited from outpatient clinics of Cardiology schoolhospitals in Porto Alegre. The patients were randomized to receive NIV through CPAP or BiPAP modes for 60 minutes. The 6MWT and echocardiogram were performed before and after the use of NIV. In CPAP mode, 8 cmH2O pressure was applied and in BiPAP mode 8 cmH2O inspiratory pressure and 4 cmH2O expiratory pressure were applied. Results: The isovolumic relaxation time (IVRT) was reduced after the use of CPAP (before = 104.7±18.9 msec. vs. after = 60.48±19.2 msec.; p<0.05) and the shortening fraction was reduced in both modes (before = 25.9±1.4% vs. after = 23.15±1.02%, p<0.05). Patients with left ventricle ejection factor (LVEF)>= 50% presented increased left ventricle end systolic diameter (LVESD) (before = 37.27±2.84mm vs. after = 41.8±2.77mm; p<0.05) and reduced LVEF (before = 61.9±2.6% vs. after = 53.32±2.9%). The functional capability was not altered with the use of NIV. Conclusion: The CPAP significantly altered the IVRT. The preserved LVEF affected the results of LV contractile function. The NIV did not cause any significant alteration to the functional capability.
|
83 |
Abordagem por ressonância magnética do mecanismo de ação da pressão expiratória positiva nasal como forma de tratamento da apneia do sonoBraga, Carla Winei January 2012 (has links)
Esta tese de doutorado aborda o assunto apneia do sono, especialmente a síndrome de apneia e hipopneia obstrutiva do sono (SAHOS) como principal motivo de investigação. Nosso estudo teve como objetivo estudar o mecanismo fisiológico de funcionamento da válvula expiratória nasal (nEPAP) denominada Provent. Trata-se de um dispositivo descartável utilizado em ambas as narinas e que permite a inspiração normal, porém oferece resistência à expiração, fazendo com que o próprio paciente gere uma determinada pressão expiratória nasal. Este mecanismo de atuação da válvula determina algum grau de modificação na via aérea superior e no pulmão. Embora já se saiba que este dispositivo é efetivo no tratamento de pacientes com SAHOS leve e moderada3 o seu mecanismo fisiológico de funcionamento ainda não está completamente entendido. Utilizamos um método de ressonância magnética para avaliar a via aérea superior e o pulmão de pacientes em utilização do Provent nasal. Estudamos dez pacientes, 7 homens e 3 mulheres, entre 30 e 62 anos, com diagnóstico clínico de SAHOS e confirmado pela polissonografia (IAH>5 ev/h). Realizamos então, em diferentes momentos, polissonografia diagnóstica, polissonografia em uso da válvula nasal e exame de imagem (ressonância magnética). A faringe e o pulmão foram inspecionados e medidos durante alguns ciclos respiratórios, com e sem a válvula nasal. Neste estudo, validamos o exame de Ressonância Magnética para a avaliação da área transversal da via aérea superior e da capacidade residual funcional durante a respiração através da válvula nasal. Com os nossos resultados reforçamos os achados anteriores da literatura referentes aos três possíveis mecanismos de funcionamento desta válvula nasal: hiperinflação pulmonar importante aumentando a tração na traqueia, uma tendência à dilatação da faringe durante a expiração que se mantém no início da inspiração reduzindo a colapsabilidade da faringe e, finalmente, hipoventilação e aumento de PCO2. Considerando estes resultados, podemos dizer que a pressão expiratória positiva nasal pode ser uma alternativa de tratamento da SAHOS. Os resultados deste estudo são apresentados sob a forma de artigo já publicado em revista internacional de alto impacto científico (Journal of Applied Physiology). Adicionalmente, na forma de apêndice, realizamos outro estudo objetivando estudar o comportamento da SAHOS na Doença de Parkinson e as alterações ocasionadas em marcadores periféricos de lesão neuronal, especificamente a proteína S100B e a Enolase. Os transtornos do sono, incluindo os distúrbios respiratórios, são frequentes nos pacientes com Doença de Parkinson (DP), e, estudos já realizados mostram que a proteína S100B pode estar aumentada tanto em pacientes com SAHOS1 como naqueles com Doença de Parkinson2, sugerindo a possibilidade de algum grau de dano neuronal nestes pacientes quando comparados com indivíduos normais. Estes achados serviram de motivação para o estudo das variáveis neurofisiológicas do sono e do comportamento de biomarcadores em pacientes com Parkinson e, supostamente, SAHOS concomitantemente. / The issue of this doctoral thesis is Obstructive Sleep Apnea (OSA). Our study intended to clarify the mechanism of action of nEPAP (Nasal Expiratory Positive Airway Pressure), delivered with a disposable device (Provent, Ventus Medical). It has been shown to improve sleep disordered breathing (SDB) in some subjects3, but how it works is still not completely understood. We studied 10 patients, 7 males and 3 females, age between 30 and 62 years old, with clinic OSA and confirmed by sleep study (IHA>5). Sleep studies were performed in different nights, a night for diagnostic of OSA and other night under nasal valve. We did use MRI (Magnetic Resonance Imaging) to see upper airway and lung in patients wearing Provent. The present study demonstrate that significant hyperinflation (an increase in end expiratory lung volume) occurs during breathing through the device. In addition, there may be some trend to dilate the UA during expiration, and this may carry over into inspiration, providing a second mechanism to reduce the tendency of the UA to collapse in patients with SDB. Finally, we were able to show significant hypoventilation and a rise in PCO2 during breathing through the nEPAP during wakefulness, which may persist into sleep. Results are presented in the format of a paper published in a international journal with high scientific impact (Journal of Applied Physiology). In addition, as appendix, we did perform other protocol intended to study OSA in the Parkinson Disease (PD) and correlation with detectable levels of S100B and NSE, biochemical markers of neuronal damage. Sleep breathing disorders are frequent in Parkinson Disease and there are some studies showing that S100B, a known biochemical marker of astrocyte damage, is increased in both SAOS and PD1 2, suggesting a possible neuronal damage while compared to controls. These findings were motivation to investigate biochemical markers and sleep in patients with Parkinson. Our results suggest that sleep disturbance in PD causes a worse sleep quality and leads to S100B elevation during the night. Probably PD patients are suffering some degree of brain damage during the night that trigger a S100B response.
|
84 |
A influência das alterações nasais na adesão ao aparelho de pressão aérea positiva em pacientes com síndrome da apneia obstrutiva do sono / The influence of nasal alterations in adherence to the continuous positive airway pressure in obstructive sleep apnea patientsHaddad, Fernanda Louise Martinho [UNIFESP] 26 January 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:13Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-01-26 / Introdução: Trabalhos vêm mostrando uma maior ocorrência de alterações nasais em pacientes com Síndrome da Apneia Obstrutiva do Sono (SAOS) quando comparados a controles, porém a correlação existente entre a permeabilidade nasal e a adesão ao aparelho de pressão aérea positiva (CPAP) é assunto ainda controverso na literatura. Além disso, não existe um consenso sobre qual ou quais seriam os melhores métodos de avaliação da função nasal. Desse modo, o objetivo deste trabalho é avaliar a influência das alterações nasais na adesão ao CPAP, em pacientes com SAOS. Método: Foram incluídos pacientes de ambos os gêneros, entre 25 a 65 anos, com diagnóstico de SAOS moderada a grave. O protocolo constituiu de questionários, rinoscopia anterior, nasofibrolaringoscopia flexível, “peak flow ” nasal inspiratório, rinometria acústica e polissonografia para titulação pressórica do CPAP. Os pacientes receberam o CPAP para uso domiciliar por 6 meses e foram acompanhados em um programa educacional. Ao término de 6 meses, os pacientes que utilizaram o CPAP 4 horas ou mais por noite, em pelo menos 70% das noites, foram considerados como tendo boa adesão; os demais como tendo má adesão. Resultados: De 45 pacientes incluídos, 34 finalizaram o estudo. Onze (33,4%) pacientes eram do sexo feminino e 23 (67,6%) do sexo masculino, com idade média de 53,1 ± 9,1 anos. Dezesseis (47,1%) pacientes apresentaram boa adesão. Os parâmetros clínicos significantes foram: índice de massa corpórea (IMC), circunferência cervical (CC) e índice de apneia e hipopneia (IAH) maiores (p=0,030, p=0,006, p=0,032); e a saturação mínima da oxihemoglobina menor (p=0,041) no grupo de boa adesão. Os parâmetros nasais não apresentaram diferenças entre os grupos. As correlações com o maior número de horas de uso do CPAP foram: maior IMC (p=0,043), maior CC (p=0,007), maior IAH (p=0,043), maior pressão do CPAP (p=0,012), menor média das áreas nasais na posição supina (p=0,029). No modelo de regressão linear, os achados relacionados ao maior número de horas de uso do CPAP foram: maior CC (p=0,015), maior IAH (p=0,034), menor nota do quadro de sintomas nasais (p=0,007) e menor volume das fossas nasais na posição supina (p=0,001). Conclusões: A maior parte dos parâmetros nasais avaliados foram contraditórios ou não influenciaram a adesão ao CPAP. Os parâmetros que se correlacionaram à adesão ao CPAP neste grupo de pacientes com SAOS foram os preditores clínicos e polissonográficos da presença e gravidade da SAOS. / Introduction: Researches showed a higher incidence of nasal disorders in patients with Obstructive Sleep Apnea Syndrome (OSAS) compared to controls, but the correlation between the nasal permeability and positive airway pressure device (CPAP) compliance is controversy in the literature. Furthermore there is no consensus on what would or would be the best methods of assessment of nasal function. Thus, the aim of this study was to evaluate the contribution of nasal alterations in CPAP compliance in patients with OSAS. Method: We included patients of both genders, between 25 to 65 years, with moderate to severe OSAS. The protocol consisted of questionnaires, rhinoscopy, nasofibroscopy, nasal inspiratory peak flow, acoustic rhinometry and polysomnography. The patients received CPAP for home use for 6 months and were followed in an educational program. At the end of 6 months, patients who used CPAP 4 hours or more per night, at least 70% of nights were considered as having good compliance, and the others as having poor compliance.Results: Of 45 patients enrolled, 34 finished the study. Eleven (33.4%) patients were female and 23 (67.6%) males, mean age 53.1 ± 9.1 years. Sixteen (47.1%) patients had good compliance (use 􀂕 4 hours per night). Clinical parameters were significant: body mass index (BMI), neck circumference (NC) and apnea-hypopnea index (AHI) higher (p = 0.030, p = 0.006, p = 0.032), and oxyhemoglobin saturation minimum minor (p = 0.041) in the group with good compliance. Nasal parameters showed no differences between groups. The correlations with the largest number of hours of CPAP use were: higher BMI (p = 0.043), higher NC (P = 0.007), higher AHI (p = 0.043), higher CPAP pressure (p = 0.012), lower average of minimal sectional areas in the supine position (p = 0.029). In the linear regression model, the findings related to the greater number of hours of CPAP use were: higher CC (p = 0.015), higher AHI (p = 0.034), lower notes of nasal symptoms (p = 0.007) and lower volume of nasal cavity in the supine position (p = 0.001). Conclusions: Most nasal parameters evaluated were contradictory or did not influence adherence to CPAP. The parameters that were significantly correlated with adherence to CPAP in this group of OSA patients were clinical and polysomnographic predictors of the presence and severity of OSA. / TEDE / BV UNIFESP: Teses e dissertações
|
85 |
Investigação dos efeitos de dois níveis de pressão expiratória positiva nas vias aéreas sobre a dispneia, hiperinsuflação pulmonar dinâmica e tolerância ao exercício em portadores de Doença Pulmonar Obstrutiva CrônicaGass, Ricardo January 2017 (has links)
Introdução: A aplicação da pressão positiva expiratória (EPAP) em pacientes com DPOC durante o exercício pode reduzir a hiperinflação dinâmica (HD) e consequentemente a dispneia, enquanto, por outro lado, pode aumentar o trabalho resistivo da respiração. O objetivo do presente estudo foi avaliar os efeitos de duas intensidades de EPAP sobre a capacidade inspiratória, dispneia e tolerância ao exercício em pacientes com DPOC moderada a muito grave. Métodos: Estudo transversal, experimental, de 4 visitas. Na visita 1, os participantes realizaram um teste de exercício cardiopulmonar incremental limitados por sintomas (TECP). Nas visitas 2-4, com pelo menos 48 horas de intervalo, em ordem aleatória, eles realizaram TECP com carga constante (TECPct; 75% da carga de pico) sem EPAP, EPAP com 5cmH2O (EPAP5), ou EPAP com 10cmH2O (EPAP10). Resultados: O estudo incluiu 15 participantes não hipoxêmicos com DPOC moderada a muito grave (média de VEF1= 35,3 ± 10,9% do previsto). As intensidades sucessivas de EPAP durante o TECPct tenderam a causar uma redução progressiva da tolerância ao exercício (p=0,11). Destaca-se que 10 dos 15 pacientes apresentaram menor duração de exercício quando o EPAP10 foi comparado ao teste sem EPAP (-151 ± 105s, p <0,01 ou -41 ± 26%). Além disso, observou-se com EPAP (p <0,05) uma redução significativa da ventilação minuto, as custas de uma restrição na expansão do volume corrente. Por fim, a sensação de dispneia e medidas seriadas da capacidade inspiratória durante o exercício não foram diferentes entre as três intervenções. Conclusão: Níveis progressivos de EPAP durante o exercício tendem a causar uma redução progressiva na tolerância ao exercício em pacientes com DPOC sem melhora na dispneia e HD. / Introduction: The application of expiratory positive aiway pressure (EPAP) in COPD patients during exercise may reduce dynamic hyperinflation (DH), and consequently dyspnea, while, on the other hand, can increase the resistive work of breathing. Therefore, the objective of the current study was to evaluate the effects of two intensities of EPAP on inspiratory capacity, dyspnea and exercise tolerance in patients with moderate to very-severe COPD. Methods: Cross-sectional, experimental, 4-visit study. In the Visit 1, participants performed symptom-limited cycling incremental cardiopulmonary exercise test (CPET). In Visits 2-4, at least 48hrs apart, in a randomized order, they performed constant CPET (ctCPET) without EPAP, EPAP with 5cmH2O (EPAP5), or EPAP with 10cmH2O (EPAP10). Results: The study included 15 non-hypoxemic subjects ranging from moderate-to-very-severe COPD (mean FEV1=35.3 ± 10.9% of predicted). Successive intensities of EPAP during ctCPET tended to cause a progressive reduction in exercise tolerance (p=0.11). Of note, 10 of 15 presented shorter exercise duration when EPAP10 was compared to the test without EPAP (-151±105s, p<0.01 or -41±26%). Moreover, significant constraint to minute-ventilation, at expenses of limited tidal volume expansion, was observed with EPAP (p<0.05). Finally, dyspnea sensation and IC measurements were similar during exercise among the interventions. Conclusion: Progressive levels of EPAP during exercise tented to cause a progressive reduction in exercise tolerance in COPD patients without improvement in exercise dyspnea and DH.
|
86 |
Efeito da fisioterapia respiratória precoce em pacientes no pós-operatório imediato de cirurgia de revascularização do miocárdio e seu impacto clínico / Early manual hyperinflation physiotherapy improves oxygenation parameters after myocardial revascularization : a randomized clinical trialBlattner, Clarissa Netto January 2008 (has links)
Objetivo: Verificar a eficácia da fisioterapia respiratória precoce, através da hiperinsuflação manual (HM) associada à pressão expiratória positiva final (PEEP) no pós-operatório de pacientes submetidos à cirurgia de revascularização do miocárdio (CRM). Método: Ensaio clínico randomizado. Participantes: Cinqüenta e cinco pacientes foram incluídos no estudo, onde o grupo intervenção foi submetido à técnica fisioterapêutica logo no pósoperatório imediato e o grupo controle recebeu a rotina assistencial do serviço. Foram avaliados parâmetros de oxigenação, através da gasometria arterial, tempo de extubação, complacência pulmonar e presença de complicações respiratórias pós-operatórias. Resultados: Houve melhora significativa no grupo intervenção quando comparado ao controle nos seguintes parâmetros: oxigenação (PaO2 93,4±5,51mmHg x 81,7±2,25mmHg – p<0,001), tempo de extubação (295,4±41,7min x 371,5±130,1min – p=0,005) e complacência estática (60,3±4,43ml/cmH2O x 51,8±3,22ml/cmH2O – p<0,001). Conclusão: O grupo que foi submetido à fisioterapia precoce com hiperinsuflação manual apresentou melhora significativa em termos de oxigenação, complacência estática e redução do tempo de permanência em ventilação mecânica, quando comparado ao grupo controle. A incidência de complicações respiratórias pós-operatórias foi similar nos dois grupos. / Question: How does immediate postoperative respiratory physiotherapy affect clinical parameters, oxygenation and static compliance after myocardial revascularization (MR), and what impact does it have on clinical outcome, pulmonary complications and intubation time? Design: Randomized clinical trial. Participants: Fifty-five patients scheduled for elective myocardial revascularization. Intervention: A physiotherapy technique was used for the intervention group immediately after surgery; the control group received the service’s routine care. Outcome measures: Oxygenation parameters were evaluated by means of arterial blood gases, extubation time, lung compliance and postoperative respiratory complications. Results: Improvement in the intervention group was significantly greater than in the control group according to the following parameters: oxygenation (PaO2 93.4±5.51 mmHg x 81.7±2.25 mmHg; p<0.001), extubation time (295.4±41.7 min x 371.5±130.1min; p=0.005) and static compliance (60.3±4.43 ml/cmH2O x 51.8±3.22 ml/cmH2O; p<0.001). Conclusion: The group that received early manual hyperinflation physiotherapy had significantly better oxygenation and static compliance and shorter mechanical ventilation times than the control group. The incidence of postoperative respiratory complications was similar in the two groups.
|
87 |
Avaliação ecocardiográfica e da capacidade funcional por ensaio clínico randomizado dos efeitos agudos de dois modos de ventilação não-invasiva nasal na insuficiência cardíaca compensadaMundstock, Lorena Contreras January 2008 (has links)
Introdução: Os efeitos agudos da ventilação não invasiva (VNI), comparando os modos continuous positive airway pressure (CPAP) versus bilevel positive airway pressure (BiPAP) devem ser melhor verificados em pacientes insuficiência cardíaca (IC) crônica. Objetivo: avaliar os efeitos agudos da VNI em pacientes com IC na resposta hemodinâmica da função cardíaca por ecocardiografia com Doppler Tissular e na avaliação da capacidade funcional através do teste de caminhada de 6 minutos (TC6min), utilizando modo CPAP versus BiPAP. Métodos vinte e seis pacientes portadores de insuficiência cardíaca selecionados de ambulatórios de cardiologia de hospitais-escola de Porto Alegre. Os pacientes foram randomizados para receber VNI pelos modos CPAP ou BiPAP durante 60 minutos. Foram realizados TC6min e ecocardiograma antes e após o uso da VNI. No modo CPAP foi utilizada pressão de 8 cmH2O, e no BiPAP foram 8 cmH2O de pressão inspiratória e 4 cmH2O de pressão expiratória. Resultados: o tempo de relaxamento isovolumétrico (TRIV) diminuiu após uso do CPAP (pré = 104,7±18,9 mseg versus pós = 60,48±19,2 mseg; p<0,05) e a fração de encurtamento (FS) diminuiu em ambos os modos (pré = 25,9±1,4% versus pós = 23,15±1,02%, P < 0,05). Entre os pacientes com fração de ejeção do ventrículo esquerdo (FEVE) >= 50%, houve aumento do diâmetro sistólico final do VE (DSFVE) (pré = 37,27±2,84mm versus pós = 41,8±2,77mm; p<0,05) e diminuição da FEVE (pré = 61,9±2,6% versus pós = 53,32±2,9%). A capacidade funcional não foi alterada com o uso da VMNI. Conclusão: O CPAP alterou significativamente o TRIV. A FEVE preservada influenciou os resultados da função contrátil do VE. A VNI não provocou alterações significativas sobre a capacidade funcional. / Introdução: The noninvasive ventilation (NIV) acute effects da ventilação não invasiva by comparing continuous positive airway pressure (CPAP) versus bilevel positive airway pressure (BiPAP) should be more investigated in patients with chronic heart failure (CHF). Objective: evaluate the acute effects of NIV in patients with heart failure (HF) in the hemodynamic response of the cardiac function through echocardiography with Tissue Doppler and in the assessment of functional capability through the 6-minute walk test (6MWT), using CPAP vs. BiPAP modes. Methods: twenty-six patients with HF recruited from outpatient clinics of Cardiology schoolhospitals in Porto Alegre. The patients were randomized to receive NIV through CPAP or BiPAP modes for 60 minutes. The 6MWT and echocardiogram were performed before and after the use of NIV. In CPAP mode, 8 cmH2O pressure was applied and in BiPAP mode 8 cmH2O inspiratory pressure and 4 cmH2O expiratory pressure were applied. Results: The isovolumic relaxation time (IVRT) was reduced after the use of CPAP (before = 104.7±18.9 msec. vs. after = 60.48±19.2 msec.; p<0.05) and the shortening fraction was reduced in both modes (before = 25.9±1.4% vs. after = 23.15±1.02%, p<0.05). Patients with left ventricle ejection factor (LVEF)>= 50% presented increased left ventricle end systolic diameter (LVESD) (before = 37.27±2.84mm vs. after = 41.8±2.77mm; p<0.05) and reduced LVEF (before = 61.9±2.6% vs. after = 53.32±2.9%). The functional capability was not altered with the use of NIV. Conclusion: The CPAP significantly altered the IVRT. The preserved LVEF affected the results of LV contractile function. The NIV did not cause any significant alteration to the functional capability.
|
88 |
Efeitos da aplicação da EPAP sobre a tolerância ao esforço em indivíduos portadores de insuficiência cardíaca / Effects of application of EPAP on exercise tolerance in individuals with heart failureThofehrn, Claudia 02 March 2012 (has links)
Made available in DSpace on 2016-12-06T17:06:54Z (GMT). No. of bitstreams: 1
Claudia Thofehrn.pdf: 804135 bytes, checksum: 1c917a778904272b382a9452df5cb3e7 (MD5)
Previous issue date: 2012-03-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Patients with heart failure (HF) are often limited by dyspnea and fatigue, often aggravated by pulmonary congestion present in this syndrome. Efficacy of Positive Expiratory Pressure Airway (EPAP) has been tested in diverse populations, as in the postoperative period of CABG surgery, stable chronic obstructive pulmonary disease and obstructive sleep apnea, providing effects such as variation in intraocular pressure alveolar, increased functional residual capacity, redistribution of extravascular fluid and decreased intrapulmonary shunt. In an attempt to reduce dyspnea and respiratory work in patients with HF using the EPAP is a therapeutic alternative in view of its beneficial effects and considering the changes in lung function are related to pulmonary edema. The aim of this study was to evaluate the effects of the use of EPAP on exercise tolerance in patients with HF, functional class II and III (NYHA). For the sample, we selected 28 patients with LVEF <40%, which conducted three tests of 6-minute walk (6MWT): learning with and without use of EPAP use of it. To generate a positive expiratory pressure, adapted to the mask expiratory resistor by a spring loaded set to offer a pressure of 8 cmH2O. The comparison between the data obtained was performed by paired t test or Wilcoxon test, depending on the normality of the data. As a result, it was found that the use of EPAP increased without significant minute volume and the perception of effort was increased after 6MWT that the associated use of positive pressure. With regard to oxygen saturation, the use of EPAP in 6MWT increased significantly the same, despite the finding baseline saturations were within normal parameters before testing. It was concluded that the use of EPAP did not increase exercise tolerance in patients with HF in the 6MWT, but there is a need for additional studies to test different levels of the same long-term training and / or analyze patients with degrees of clinic more pronounced. / Pacientes portadores de Insuficiência Cardíaca (IC) frequentemente são limitados pela dispnéia e fadiga, muitas vezes agravadas pela congestão pulmonar presentes nesta síndrome. A eficácia da Pressão Positiva Expiratória nas Vias Aéreas (EPAP) já foi testada em diversas populações, como em pós-operatório de cirurgia de revascularização miocárdica, doença pulmonar obstrutiva crônica estável e apneia obstrutiva do sono, proporcionando efeitos como a variação na pressão intra-alveolar, aumento da capacidade residual funcional, redistribuição do líquido extravascular e diminuição do shunt intrapulmonar. Na tentativa de reduzir a dispnéia e o trabalho ventilatório em portadores de IC o uso da EPAP é uma alternativa terapêutica, tendo em vista seus efeitos benéficos e considerando que as alterações na função pulmonar estão relacionadas à edema pulmonar. O objetivo desta pesquisa foi avaliar os efeitos da utilização da EPAP sobre a tolerância ao esforço em indivíduos portadores de IC, classe funcional II e III (NYHA). Para a amostra, foram selecionados 28 pacientes com FEVE < 40%, os quais realizaram três testes de caminhada de 6 minutos (TC6 ): aprendizado, com uso da EPAP e sem uso da mesma. Para gerar a pressão positiva expiratória, adaptou-se à uma máscara um resistor expiratório por carga de mola ajustado para oferecer uma pressão de 8 cmH2O. A comparação entre os dados obtidos foi realizada por meio de teste t pareado ou teste de Wilcoxon, conforme a normalidade dos dados. Como resultado, verificou-se que o uso da EPAP aumentou sem significância o volume minuto, porém a percepção de esforço foi maior após o TC6 que associou o uso da pressão positiva. Com relação à saturação de oxigênio, o uso da EPAP no TC6 elevou a mesma significativamente, apesar das saturações basais encontrarem-se dentro de parâmetros normais antes da realização do teste. Concluiu-se que o uso da EPAP não promoveu aumento na tolerância ao esforço em indivíduos portadores de IC no TC6 , porém, há a necessidade de estudos adicionais que testem níveis diferentes da mesma no treinamento a longo prazo e/ou analisem pacientes com graus de descompensação clínica mais acentuada.
|
89 |
Efeito agudo do freno labial na hiperinsuflação dinâmica induzida pelo exercício e AVD em pacientes com DPOC / Acute effect of imposed pursed-lips breathing on dynamic hyperinflation induced by exercise and ADL in COPD patientsAraujo, Cintia Laura Pereira de 04 July 2013 (has links)
Made available in DSpace on 2016-12-12T17:32:55Z (GMT). No. of bitstreams: 1
Cintia Laura Pereira de Araujo.pdf: 891905 bytes, checksum: 68d6cdcc41dfe7c353a29f0ca21b680c (MD5)
Previous issue date: 2013-07-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Evidence has shown that dynamic hyperinflation (DH) is an important factor leading to dyspnea and consequent limitations in functional capacity of COPD patients. It is not been completely elucidated whether the pursed-lips breathing (PLB) is able to minimize DH and its effects on exercise tolerance in these patients. The aim of this study was to evaluate the acute effect of PLB on DH and functional capacity in patients with COPD. Twenty-five patients with COPD (16 men, mean age 64±7 years, FEV1=41.7±14.7% predicted, BMI=27.6±5.13kg/m2) randomly performed two six-minute walk tests with and without PLB (6MWTPLB and 6MWTNon-PLB) and two Glittre-ADL tests with and without PLB (TGlittrePLB e TGlittreNon-PLB). At baseline and immediately after the tests, the inspiratory capacity (IC) was assessed by the slow vital capacity (SVC) maneuver. The 6MWTNon-PLB and TGlittreNon-PLB induced similar DH magnitude (0.22±0.24L and. 0.31±0.23L respectively; p>0.05). PLB did not improve DH induced by the 6MWT (0.24±0.20L PLB and 0.22±0,24L non-PLB, respectively; p>0.05). DH in the TGlittrePLB was significantly lower than TGlittreNon-PLB (0.19±0.20L and 0.31±0.23L, respectively; p=0.02). PLB did not improve exercise tolerance neither on the 6MWT (457±63m PLB and 466±71m Non-PLB, respctively; p>0.05) or on the TGlittre (4.38min PLB and 4.23min Non-PLB, respectively; p>0.05). In conclusion, PLB reduced DH only on TGlittre and did not improve functional capacity. / Evidências têm demonstrado que a hiperinsuflação dinâmica é um dos fatores que levam a dispneia e consequente limitação na capacidade funcional de indivíduos com DPOC. Não está completamente elucidado se o freno labial (FL) é capaz de minimizar a hiperinsuflação dinâmica e seus efeitos na tolerância ao exercício nesses pacientes. O objetivo desse estudo foi avaliar os efeitos agudos do freno labial na hiperinsuflação dinâmica e na tolerância ao exercício em pacientes com DPOC moderada a muito grave. Vinte e cinco pacientes com DPOC (16 homens, 64±7 anos, VEF1=41,7±14,7% do previsto, IMC=27,6±5,13kg/m2) realizaram em dois dias, de forma aleatória dois testes de caminhada de seis minutos com e sem freno labial (TC6MFL e TC6MSem-FL) e dois testes de AVD-Glittre com e sem freno labial (TGlittreFL e TGlittreSem-FL). Antes e após cada teste foi avaliada a capacidade inspiratória (CI), por meio de espirometria simples com manobra de capacidade vital lenta (CVL) para avaliar a hiperinsuflação dinâmica (HD). O TC6MSem- FL e TGlittreSem-FL induziram similar magnitude de HD (0.22±0.24L vs. 0.31±0.23L; p>0.05). HD induzida pelo TGlittreFL foi significativamente menor que a induzida pelo TGlittreSem-FL (0.19±0.20L vs. 0.31±0.23L; p=0.02). FL não melhorou a HD induzida pelo TC6M (0.24±0.20L FL vs. 0.22±0,24L Sem-FL; p>0.05). FL não melhorou o desempenho no TC6M (457±63m FL vs. 466±71m Sem-FL; p>0.05); nem no TGlittre (4.38min FL vs. 4.23min Sem-FL; p>0.05). Conclui-se que o FL reduziu apenas a HD induzida pelo TGlittre e não melhorou o desempenho nos testes.
|
90 |
Investigação dos efeitos de dois níveis de pressão expiratória positiva nas vias aéreas sobre a dispneia, hiperinsuflação pulmonar dinâmica e tolerância ao exercício em portadores de Doença Pulmonar Obstrutiva CrônicaGass, Ricardo January 2017 (has links)
Introdução: A aplicação da pressão positiva expiratória (EPAP) em pacientes com DPOC durante o exercício pode reduzir a hiperinflação dinâmica (HD) e consequentemente a dispneia, enquanto, por outro lado, pode aumentar o trabalho resistivo da respiração. O objetivo do presente estudo foi avaliar os efeitos de duas intensidades de EPAP sobre a capacidade inspiratória, dispneia e tolerância ao exercício em pacientes com DPOC moderada a muito grave. Métodos: Estudo transversal, experimental, de 4 visitas. Na visita 1, os participantes realizaram um teste de exercício cardiopulmonar incremental limitados por sintomas (TECP). Nas visitas 2-4, com pelo menos 48 horas de intervalo, em ordem aleatória, eles realizaram TECP com carga constante (TECPct; 75% da carga de pico) sem EPAP, EPAP com 5cmH2O (EPAP5), ou EPAP com 10cmH2O (EPAP10). Resultados: O estudo incluiu 15 participantes não hipoxêmicos com DPOC moderada a muito grave (média de VEF1= 35,3 ± 10,9% do previsto). As intensidades sucessivas de EPAP durante o TECPct tenderam a causar uma redução progressiva da tolerância ao exercício (p=0,11). Destaca-se que 10 dos 15 pacientes apresentaram menor duração de exercício quando o EPAP10 foi comparado ao teste sem EPAP (-151 ± 105s, p <0,01 ou -41 ± 26%). Além disso, observou-se com EPAP (p <0,05) uma redução significativa da ventilação minuto, as custas de uma restrição na expansão do volume corrente. Por fim, a sensação de dispneia e medidas seriadas da capacidade inspiratória durante o exercício não foram diferentes entre as três intervenções. Conclusão: Níveis progressivos de EPAP durante o exercício tendem a causar uma redução progressiva na tolerância ao exercício em pacientes com DPOC sem melhora na dispneia e HD. / Introduction: The application of expiratory positive aiway pressure (EPAP) in COPD patients during exercise may reduce dynamic hyperinflation (DH), and consequently dyspnea, while, on the other hand, can increase the resistive work of breathing. Therefore, the objective of the current study was to evaluate the effects of two intensities of EPAP on inspiratory capacity, dyspnea and exercise tolerance in patients with moderate to very-severe COPD. Methods: Cross-sectional, experimental, 4-visit study. In the Visit 1, participants performed symptom-limited cycling incremental cardiopulmonary exercise test (CPET). In Visits 2-4, at least 48hrs apart, in a randomized order, they performed constant CPET (ctCPET) without EPAP, EPAP with 5cmH2O (EPAP5), or EPAP with 10cmH2O (EPAP10). Results: The study included 15 non-hypoxemic subjects ranging from moderate-to-very-severe COPD (mean FEV1=35.3 ± 10.9% of predicted). Successive intensities of EPAP during ctCPET tended to cause a progressive reduction in exercise tolerance (p=0.11). Of note, 10 of 15 presented shorter exercise duration when EPAP10 was compared to the test without EPAP (-151±105s, p<0.01 or -41±26%). Moreover, significant constraint to minute-ventilation, at expenses of limited tidal volume expansion, was observed with EPAP (p<0.05). Finally, dyspnea sensation and IC measurements were similar during exercise among the interventions. Conclusion: Progressive levels of EPAP during exercise tented to cause a progressive reduction in exercise tolerance in COPD patients without improvement in exercise dyspnea and DH.
|
Page generated in 0.0633 seconds