• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 10
  • 1
  • 1
  • Tagged with
  • 42
  • 42
  • 42
  • 30
  • 30
  • 30
  • 15
  • 14
  • 10
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Neobexiga gastroileal ortotópica e gastroileocistoplastia laparoscópicas: viabilidade técnica e análise crítica de um modelo experimental em suínos / Laparoscopic orthotopic gastroileal neobladder and gastroileocystoplasty: technical feasibility and critical analysis of an experimental porcine model

Eduardo Franco Carvalhal 13 September 2004 (has links)
Introdução: Reservatórios gastroileais (GI) compostos podem apresentar vantagens em relação a segmentos intestinais isolados em cirurgias de reconstrução urinária em pacientes selecionados. Apresentamos aqui as técnicas laparoscópicas de gastroileocistoplastia (ampliação vesical) e de neobexiga gastroileal ortotópica (substituição vesical), realizadas de forma completamente intracorpórea em um modelo suíno experimental. Avalia-se sua viabilidade técnica e resultados funcionais. Métodos: Após padronização da técnica em estudo piloto (três animais), realizaram-se as cirurgias de gastroileocistoplastia (Grupo I; N = 5) e neobexiga GI ortotópica (Grupo II; N = 10), envolvendo os mesmos princípios de ressecção laparoscópica de cunha gástrica e íleo. No grupo II, a criação da neobexiga GI incluiu reimplante ureteral bilateral no segmento gástrico com técnica antirefluxo e anastomose uretro-ileal. Foram utilizados exclusivamente grampeadores e técnicas de sutura livre laparoscópica, de forma completamente intracorpórea. Análise pré e pós-operatória de dados laboratoriais, capacidade vesical, avaliação histológica e por imagem (uretrocistografia, urografia venosa) dos reservatórios resultantes foi concluída ao final do seguimento de 8 a 12 semanas (Grupo I) e quatro a oito semanas (Grupo II). Resultados: Os segmentos ileal e gástrico alcançaram a pelve do animal em todos os casos. Tempo cirúrgico foi de 5,2 h para o Grupo I e 7,4 h para o Grupo II. Não houve conversões ou óbitos intra-operatórios. Todos os reservatórios GI apresentavam-se viáveis por ocasião da eutanásia em ambos os grupos. No Grupo I, quatro dos cinco animais completaram sem intercorrências o seguimento de 8 (N = 2) e 12 (N = 2) semanas. Um animal apresentou deterioração clínica, sendo levado precocemente à eutanásia por pielonefrite e alcalose metabólica. Houve aumento da capacidade vesical (a uma pressão vesical de 20cmH2O) de 650ml para 1025ml (p < 0,05) após a cirurgia de ampliação vesical. No Grupo II, cinco dos 10 animais completaram o seguimento previsto em quatro (N = 3) e oito (N = 2) semanas, com mínima alteração da função renal (Cr pré e pós-operatório=1,4 e 2,2mg/dl, respectivamente; p = 0,09). Três animais tiveram a eutanásia antecipada devido a obstrução ureteral com pielonefrite (N = 2) e alcalose hipoclorêmica severa (N=1). Dois óbitos foram associados a obstrução ureteral bilateral e sepse. Capacidade vesical média das neobexigas foi de 400ml. Não houve casos de refluxo vesico-ureteral à cistografia. Porém, sete das 20 unidades renais (35%) apresentaram estenose uretero-gástrica. Obstrução intestinal (N = 1), fístula gástrica (N = 1) e urinoma (N = 1) foram outras complicações do Grupo II. Conclusões: A ressecção gástrica laparoscópica para ampliação e substituição vesicais é viável e reprodutível. A gastroileocistoplastia laparoscópica apresenta adequado resultado funcional após três meses no modelo suíno. A neobexiga GI laparoscópica é tecnicamente viável no modelo suíno, apesar de sua complexidade. A descrição inicial é apresentada. Aperfeiçoamento da técnica de reimplante ureteral anti-refluxo laparoscópico é necessário antes de sua aplicação clínica. / Introduction: Composite gastroileal (GI) urinary reservoirs may present advantages over the use of isolated intestinal segments for urinary reconstructive procedures in selected patients. Herein, we present the laparoscopic techniques of gastroileocystoplasty (bladder augmentation) and GI orthotopic neobladder (bladder substitution), performed completely intracorporeally in a porcine model. Technical feasibility and functional results of these procedures are evaluated. Methods: After a pilot study (three animals) to technically standardize the procedures, gastroileocystoplasty (Group I, N = 5) and GI orthotopic neobladder (Group II; N = 10) were performed applying the same principles of wedge gastric resection and ileal resection. In Group II, creation of the neobladder included bilateral ureteral reimplantation into the gastric segment with an anti-reflux technique and an urethro-ileoanastomosis. Staplers and free-hand laparoscopic suture techniques were utilized exclusively, in a completely intracorporeal manner. Preop and postoperative analysis of laboratory data, bladder capacity, image (cystourethrography, intravenous urography) and histological evaluation of the resulting GI reservoirs was concluded at the end of follow-up, at eight and 12 weeks (Group I) and four and eight weeks (Group II). Results: Ileal and gastric patches reached the animal pelvis in all cases. Operative times were 5.2h for Group I and 7.4h for Group II. No conversions or intraoperative deaths occurred. All GI reservoirs were viable by the time of euthanasia in both groups. In Group I, four of the five animals completed the scheduled follow-up of 8 (N = 2) and 12 (N = 2) weeks without complications. One animal received early euthanasia due to pyelonephritis and metabolic alkalosis. Bladder capacity (at a bladder pressure of 20cmH2O) increased from 650ml to 1025ml (p < 0.05) after the bladder augmentation procedure. In Group II, five of 10 animals completed the scheduled follow-up at four (N = 3) and eight (N = 2) weeks, with minimal alteration on renal function (pre and postoperative Cr = 1.4 and 2.2mg/dl, respectively; p = 0.09). Three animals had an early euthanasia due to ureteral obstruction and pyelonephritis (N=2) and severe hipochloremic alkalosis (N = 1). Two deaths were associated to bilateral ureteral obstruction and sepsis. Mean bladder capacity for the neobladders was 400ml. No cases of vesico-ureteral reflux were seen at cystourethrography. However, seven of 20 renal units (35%) presented with uretero-gastric stenosis. Bowel obstruction (N = 1), gastric fistula (N = 1) and urinoma (N = 1) were other complications in Group II. Conclusions: Laparoscopic gastric resection for bladder augmentation and substitution purposes is feasible and reproducible. Laparoscopic gastroileocystoplasty presents adequate functional results after three months in the porcine model. Laparoscopic GI neobladder is technically viable in the porcine model, despite its complexity. The initial report is presented. Refinements of laparoscopic anti-reflux ureteral reimplantation techniques are necessary before its clinical application.
32

Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon technique

Marco Antonio Vieira Guedes 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
33

Emprego de veias preservadas em glicerol como substituto de enxerto de nervo: estudo experimental em ratos / Use of glycerol preserved veins as substitute of nerve graft: experimental study in rats

Armando dos Santos Cunha 03 September 2007 (has links)
Grandes perdas de tecido neural não permitem a reparação por meio de anastomose primária. Nesses casos, a auto-enxertia de nervo é considerado o melhor tratamento. A despeito de um tratamento cirúrgico adequado, déficits funcionais são observados e melhoras quanto à recuperação funcional e diminuição das seqüelas são desejáveis. Várias são as técnicas que almejaram esse propósito. A interposição de condutores tubulares, como ponte entre os cotos proximal e distal do nervo seccionado, apresenta-se como uma técnica alternativa que oferece vantagens teóricas. A veia é um material estudado como possível condutor tubular avaliado experimentalmente e em casos clínicos. Estudos recentes têm dado importância na utilização de transplantes de tecidos armazenados em banco de tecidos. O glicerol é utilizado para preservação de tecidos, tendo sido relatado seu uso em nervos e vasos. Entretanto, não há relatos da utilização de veias preservadas em glicerol como substituto de enxerto de nervo. O objetivo deste trabalho foi comparar, em ratos, o grau de regeneração neural, utilizando análise histológica e análise funcional, obtida com a interposição de enxerto autógeno de nervo, veia autógena, veia autógena preservada em glicerol e veia alógena preservada em glicerol. Com técnica microcirúrgica, foram criados defeitos de 5 mm do nervo fibular de ratos da raça Lewis. Os animais foram divididos em quatro grupos de seis, de acordo com o tratamento empregado para correção do defeito: nos animais do Grupo A (grupo controle), foi realizado o reposicionamento do fragmento de nervo retirado (auto-enxerto); nos animais do Grupo B, foi interposto um segmento de 1 cm de veia jugular externa autógena; nos animais do Grupo C, foi interposto a veia jugular externa autógena preservada em glicerol a 98% a 4ºC por sete dias; no Grupo D os animais doadores foram ratos da raça Sprague-Dawley que tiveram a veia jugular externa preservada em glicerol de forma igual ao Grupo C e utilizadas para reconstrução do defeito neural em ratos da raça Lewis, sendo considerado um enxerto alógeno preservado em glicerol. Os animais foram sacrificados após seis semanas para realização dos estudos histológicos. Para a avaliação da recuperação funcional foram estudados os padrões de deambulação dos ratos (\"walking track analysis\") no pós-operatório imediato, 3 e 6 semanas de pós-operatório. O grupo controle (auto-enxerto) apresentou resultados histológicos semelhantes aos grupos de veias preservadas em glicerol (autógena e alógena), entretanto apresentou uma maior reação tecidual perineural e maior presença de escape axonal se comparada a todos os grupos. A utilização de veia autógena sem preservação demonstrou padrão histológico com maior neoangiogênese e áreas de rarefação axonal com presença de tecido conectivo no estroma neoformado. O padrão histológico foi semelhante nos demais grupos. O grupo que utilizou veia autógena (sem glicerol) apresentou menor recuperação funcional quando comparado com os demais grupos para 3 e 6 semanas. O resultado funcional foi estatisticamente semelhante entre os grupos de veias preservadas (autógena e alógena) e o auto-enxerto. / Great losses of neural tissue cannot be repaired by primary conventional suturing. In such cases, nerve autografting is considered to be the treatment of choice. In spite of adequate surgical treatment, functional deficits occur. Also, improvement in functional recuperation and decrease in sequelae are expected. There are many techniques aiming at this purpose. The interposition of tubular conduits, as a bridge between the ends of a sectioned nerve, among these the vein graft, is an alternative technique which offers theoretical advantages. The vein is a studied material as possible evaluated tubular conductor experimentally and in clinical cases. Recent studies have given importance in the use of tissues transplants stored in banks. Glycerol is used for tissue preservation, having been told to its use in nerves and vessels. However, it does not have studies of the use of glycerol reserved veins in as substitute of nerve graft. The purpose of this study was to compare, in rats, the neural regeneration degree, using histological analysis and functional analysis, obtained after interposition of a nerve graft, autogenous vein, autogenous vein preserved in glycerol and allograft vein preserved in glycerol. A 5 mm neural gap in the fibular nerve of rats (Lewis breed) has been created under microsurgical techinique. Four groups of six animals each have been divided according to the treatment employed: Group A - control group: replacement of the fibular nerve itself (autograft); Group B - a 1omm segment of external jugular vein was interposed; Group C - a preserved external jugular vein in glycerol 98% per 7 days was interposed in the fibular nerve gap; Group D - external jugular vein preserved in glycerol of Sprague-Dawley rats had been used equal form to group C in Lewis rats. The animals had been sacrificed after 6 weeks for accomplishment of the histological studies. The functional walking track analysis was performed after in the pre-op, and in the pos-op (immediately, 3 and 6 weeks). The control group (autograft) presented similar histological results to the groups of glycerol preserved veins (autogenous vein and allograft vein), however it presented a bigger perineural tecidual reaction and bigger presence of escape axonal if compared with all the groups. The use of autogenous vein without preservation demonstrated histological results with greater neoangiogenesis and presence of connective tissue inside the neo-formed stroma. Histological pattern was similar to other studied groups. The group that used autogenous vein (without glycerol) presented little functional recovery for 3 and 6 weeks. No statistical difference was seen between groups A (autograft) and groups C and C(preserved veins) in the degree of functional recovery.
34

"Estudo anatômico comparativo entre o retalho escapular e o retalho perfurante da artéria toracodorsal" / Comparative anatomical study between the thoracodorsal artery perforator flap and the scapular flap

Luís Henrique Ishida 16 August 2006 (has links)
Desde a primeira descrição do retalho perfurante de artéria toracodorsal (TAP), sua indicação tem sido questionada por se tratar de um retalho de características semelhantes aos retalhos fasciocutâneos escapulares baseados na artéria circunflexa escapular, que são bem conhecidos e reprodutíveis. Este estudo visa comparar características anatômicas destes dois retalhos, distinguindo-os para uma melhor indicação. Adicionalmente o estudo visa estudar o posicionamento do pedículo perfurante do retalho TAP. Vinte e um pares de retalhos (TAP e escapular) foram dissecados simultaneamente em cadáveres frescos. Os músculos latíssimo do dorso e redondo maior foram seccionados e os dois retalhos foram retirados em peça única. O comprimento do pedículo, diâmetro externo da artéria e da veia, espessura da derme e espessura do tecido celular subcutâneo de ambos os retalhos foram avaliados e comparados de forma pareada. A localização dos pedículos dos retalhos foi avaliada em ambos os retalhos. Os dados obtidos foram analisados estatisticamente através do teste t de Student. O retalho TAP apresentou um pedículo com média de 16,95 cm de comprimento, sendo 50% maior que o do retalho escapular (p<0,05). A espessura média da derme foi 2,12 mm, sendo 42% mais fina do que a do retalho escapular; e a do tecido subcutâneo foi 1,37 cm, sendo 28% mais fina do que a do retalho escapular (p<0,05). O pedículo do retalho TAP apresentou artéria com diâmetro médio de 3,14 mm e veia com diâmetro médio de 3,03 mm, enquanto o pedículo do retalho escapular apresentou artéria com diâmetro médio de 3,33 mm e veia com diâmetro médio de 2,95mm, ambos sem diferenças estatísticas. Nas dissecções estudadas, todos os pedículos dos retalhos escapulares se localizavam no “espaço triangular”. Já a localização dos pedículos perfurantes do retalho TAP não apresentou nenhum parâmetro constante. O estudo demonstrou que, apesar de se localizarem em sítios anatômicos adjacentes, o retalho TAP possui um pedículo mais longo e sua pele é mais fina do que o retalho escapular. Por outro lado, o posicionamento do pedículo do retalho escapular é constante, enquanto o pedículo perfurante do retalho TAP possui localização variável. / Indication of the thoracodorsal artery perforator (TAP) flap has been questioned because its characteristics are similar to those of scapular flaps based on the scapular circumflex artery. The scope of this study is to compare the anatomic features of these two flaps, differentiating them for a better indication. Twenty-one pairs of flaps (TAP and scapular) were dissected simultaneously in fresh cadavers. The length of the pedicles, thickness of the arteries and veins of the pedicles, and the thickness of the dermis and subcutaneous tissue of the flaps were assessed and compared. The position of the pedicles of both flaps was evaluated. The average length of the TAP flap pedicle was 16.95 cm, and it was 50% longer than the scapular flap (p<0.05). The mean thickness of the dermis was 2.12 mm and of the subcutaneous tissue 1.37 cm, respectively 42% and 28% thinner than the scapular flaps (p<0.05). No significant difference was evident between the thicknesses of the pedicles. The TAP arterial pedicle was 3.14 mm and the venous one 3.03 mm. The scapular flap demonstrated a 3.33 mm arterial pedicle and 2.95 mm for the venous one. The evaluation of the position of the pedicle of the scapular flap was constant; on the other hand, the perforator pedicle of the TAP flap did not show any constant anatomical parameter. The study revealed that although the TAP flap and the scapular flap lie in adjacent anatomical areas, the TAP flap has a longer pedicle and a thinner skin; their vascular pedicles have similar thickness; though the position of the thoracodorsal perforator pedicle is variable, when compared with the scapular flap.
35

Reconstrução de defeito de nervo fibular em ratos com veia glicerolada: análise histológica e funcional / Peroneal nerve gap reconstruction in rats by using glycerol-preserved veins: histological and functional assessment

Armando dos Santos Cunha 28 May 2013 (has links)
A auto-enxertia de nervo é considerado o melhor tratamento para a restauração de grandes perdas de nervo periférico. Mesmo com o tratamento cirúrgico adequado, déficits funcionais são observados e melhoras quanto à recuperação funcional e diminuição das seqüelas são desejáveis. Várias são as técnicas que almejaram esse propósito. A interposição de condutores tubulares, como ponte entre os cotos proximal e distal do nervo seccionado, apresenta-se como uma técnica alternativa que oferece vantagens teóricas. A veia é um material estudado como possível condutor tubular avaliado experimentalmente e em casos clínicos. Estudos recentes têm dado importância na utilização de transplantes de tecidos armazenados em banco de tecidos. O glicerol é utilizado para preservação de tecidos, tendo sido relatado seu uso em nervos e vasos. Entretanto, não há relatos da utilização de veias preservadas em glicerol como substituto de enxerto de nervo. O objetivo deste trabalho foi comparar, em ratos, o grau de regeneração neural, utilizando análise histológica qualitativa e quantitativa e a recuperação funcional, obtida com a interposição de enxerto autógeno de nervo, veia autógena, veia autógena preservada em glicerol e veia alógena preservada em glicerol. Com técnica microcirúrgica, foram criados defeitos de 5 mm do nervo fibular de ratos da raça Lewis. Os animais foram divididos em quatro grupos de seis, de acordo com o tratamento empregado para correção do defeito: nos animais do Grupo A (grupo controle), foi realizado o reposicionamento do fragmento de nervo retirado (auto- enxerto); nos animais do Grupo B, foi interposto um segmento de 1 cm de veia jugular externa autógena; nos animais do Grupo C, foi interposto a veia jugular externa autógena preservada em glicerol a 98% a 4ºC por sete dias; no Grupo D os animais doadores foram ratos da raça Sprague-Dawley que tiveram a veia jugular externa preservada em glicerol de forma igual ao Grupo C e utilizadas para reconstrução do defeito neural em ratos da raça Lewis, sendo considerado um enxerto alógeno preservado em glicerol. Os animais foram sacrificados após seis semanas para realização dos estudos histológicos. Para a avaliação da recuperação funcional foram estudados os padrões de deambulação dos ratos (walking track analysis)no pós-operatório imediato, 3 e 6 semanas de pós-operatório. O grupo controle (auto-enxerto) apresentou resultados histológicos semelhantes aos grupos de veias preservadas em glicerol (autógena e alógena), entretanto apresentou uma maior reação tecidual perineural e maior presença de escape axonal se comparada a todos os grupos. A utilização de veia autógena sem preservação demonstrou padrão histológico com maior neoangiogênese e áreas de rarefação axonal com presença de tecido conectivo no estroma neoformado. O padrão histológico foi semelhante nos demais grupos. A análise histológica quantitativa demonstrou estatisticamente menor concentração de axônios regenerados no grupo B (veia autógena) do que a dos demais grupos. O grupo que utilizou veia autógena (sem glicerol) apresentou menor recuperação funcional quando comparado com os demais grupos para 3 e 6 semanas. O resultado funcional foi estatisticamente semelhante entre os grupos de veias preservadas (autógena e alógena) e o auto-enxerto / Nerve autografting is considered the best treatment for the restoration of great losses of peripheral nerve. In spite of adequate surgical treatment, functional deficits occur. Also, improvement in functional recuperation and decrease in sequelae are expected. There are many techniques aiming at this purpose. The interposition of tubular conduits, as a bridge between the ends of a sectioned nerve, among these the vein graft, is an alternative technique which offers theoretical advantages. The vein is a studied material as possible evaluated tubular conductor experimentally and in clinical cases. Recent studies have given importance in the use of tissues transplants stored in banks. Glycerol is used for tissue preservation, having been told to its use in nerves and vessels. However, it does not have studies of the use of glycerol reserved veins in as substitute of nerve graft. The purpose of this study was to compare, in rats, the neural regeneration degree, using qualitative and quantitative histological analysis and functional recovery, obtained after interposition of a nerve graft, autogenous vein, autogenous vein preserved in glycerol and allograft vein preserved in glycerol. A 5 mm neural gap in the fibular nerve of rats (Lewis breed) has been created under microsurgical techinique. Four groups of six animals each have been divided according to the treatment employed: Group A Î control group: replacement of the fibular nerve itself (autograft); Group B Î a 1omm segment of external jugular vein was interposed; Group C Î a preserved external jugular vein in glycerol 98% per 7 days was interposed in the fibular nerve gap; Group D - external jugular vein preserved in glycerol of Sprague-Dawley rats had been used equal form to group C in Lewis rats. The animals had been sacrificed after 6 weeks for accomplishment of the histological studies. The functional walking track analysis was performed after in the pre-op, and in the pos-op (immediately, 3 and 6 weeks). The control group (autograft) presented similar histological results to the groups of glycerol preserved veins (autogenous vein and allograft vein), however it presented a bigger perineural tecidual reaction and bigger presence of escape axonal if compared with all the groups. The use of autogenous vein without preservation demonstrated histological results with greater neoangiogenesis and presence of connective tissue inside the neo- formed stroma. Histological pattern was similar to other studied groups. Quantitative histological analysis showed statistically lower concentration of regenerated axons in group B (autogenous vein) than the other groups.The group that used autogenous vein (without glycerol) presented little functional recovery for 3 and 6 weeks. No statistical difference was seen between groups A (autograft) and groups C and C (preserved veins) in the degree of functional recovery
36

Ultrassonografia intraoperatória para avaliação da necessidade de duroplastia no tratamento cirúrgico de doentes com malformação de Chiari tipo I / Intra operative ultrasonography for evaluation of the need of duroplasty in surgery for Chiari I malformation

Brock, Roger Schmidt 03 April 2017 (has links)
Objetivos: Malformação de Chiari do tipo I (MC-I) é a principal doença malformativa congênita da junção craniovertebral, manifestando-se com ampla variedade de sinais e sintomas neurológicos. A melhor técnica cirúrgica a ser empregada no tratamento dos pacientes com malformação de Chiari do tipo I é ainda controversa. A descompressão das estruturas da fossa craniana posterior com plástica de ampliação dural é considerada procedimento padrão. Embora efetiva e de baixa morbidade, a craniectomia occipital isolada, sem abertura e ampliação dural, implica maior taxa de recidiva dos sintomas. Métodos que selecionam os pacientes quanto a necessidade da duroplastia não foram estabelecidos. O presente trabalho avalia a eficácia da mensuração intraoperatória da velocidade do fluxo do líquido cefalorraquidiano através da ultrassonografia (USG) na seleção da técnica cirúrgica a ser utilizada. Métodos: Foram analisados de forma prospectiva 49 pacientes submetidos à cirurgia para MC-I. A indicação de craniectomia da fossa posterior associada ou não à plástica de ampliação da dura-máter baseou-se na velocidade do fluxo do líquido cefalorraquidiano, mensurada pela ultrassonografia intraoperatória. Dor cervical, cefaleia e qualidade de vida foram avaliadas antes e após o tratamento cirúrgico. Resultados: Dos 49 pacientes incluídos, 36 pacientes (73%) apresentavam fluxo do líquido cefalorraquidiano superior a 3 cm/s e não foram submetidos a duroplastia ampliadora. Nos 13 (27%) pacientes com fluxo inicial inferior a 3 cm/s, indicou-se craniectomia occipital com duroplastia de ampliação. Não houve diferença significativa entre os dois grupos com relação aos parâmetros estudados. Conclusão: A ultrassonografia intraoperatória com avaliação da dinâmica e velocidade do fluxo do líquido cefalorraquidiano da junção craniovertebral auxilia a indicação de duroplastia durante descompressão da fossa craniana posterior em pacientes adultos com MC-I / Objectives: Chiari malformation Type I (CM-I) is the main congenital malformation disease of the craniovertebral junction, and may be responsible for a variety of neurological symptoms. The ideal surgical technique used to treat patients with CM-I is still controversial. Invasive procedures that enters CSF space and are associated with dural repair, are considered the gold standard. Although effective and less morbidity, isolated bone decompression without dural opening, implies greater recurrence of symptoms. Objective parameters to select patients, who need or not to have a duroplasty performed, have not been established. Our study evaluates the efficacy of intra-operative CSF flow measurement through the use of ultrasonography (USG) as a determining parameter in the selection of these patients. Methods: We analyzed prospectively 49 posterior fossa surgeries for patients with CM-I. Patients underwent decompressive surgery with or without opening of the dura mater after conducting USG intra-operatively with measured flow rate, being adopted 3cm/s flow rate as a determining value. The quality of life before and after surgery and the improvement of neck pain and headache were the parameters evaluated. Results: Of the 49 patients enrolled, 36 patients (73%) had adequate CSF flow above 3 cm / s and have not undergone duroplasty. In 13 (27%) patients with initial flow < 3 cm / s an opening in dura mater was performed together with duroplasty. There was no significant difference between the two groups regarding the parameters studied. Conclusion: Intraoperative ultrasound with measurement of CSF flow, having a flow of 3 cm / s as cut-off, allows the proper selection of patients with CM-I that can have a less invasive surgery with bone decompression without duroplasty
37

"Influência da composição de carreador biodegradável na viabilidade do implante de células mesenquimais indiferenciadas do tecido adiposo humano" / Influence of scaffold composition in the viability of implantation of human adipose derived undifferentiated mesenchymal cells

Dietrich, Isa 09 December 2004 (has links)
Células mesenquimais indiferenciadas humanas foram obtidas por digestão enzimática e centrifugação do produto de lipoaspiração, expandidas in vitro, e implantadas no tecido subcutâneo de camundongos atímicos. No grupo I, cada animal recebeu o implante de uma membrana de 0,25cm2 de ácido glicólico e carbonato de trimetileno semeada com 1 x 106 destas células .No grupo II, cada um recebeu a injeção de 0,2ml de gel de ácido hialurônico reticulado contendo o mesmo número destas células. Com três semanas de implante, células humanas e vasos foram identificados nos dois carreadores. Entretanto, com oito semanas, somente no gel de ácido hialurônico as células humanas e os vasos estavam presentes / Human undifferentiated mesenchymal cells were obtained by enzymatic digestion and centrifugation of the product of liposuction. These cells were expanded, in vitro, and implanted subcutaneously in athymic mice. In group I, each animal received the implant of a 0,25cm2 membrane of glycolic acid and trimethylene carbonate, seeded with 1 x 106 of these cells. In group II, each one received 0,2 ml of cross-linked hyaluronic acid gel containing the same amount of these cells. With three weeks of implantation, human cells and vessels were identified in both carriers. However, with eight weeks of implantation, only in hyaluronic acid gel human cells and vessels were present
38

Avaliação do impacto do processo de limpeza na esterilização de medidores de implantes mamários / Assesment of the cleaning process impact in sterilization of mamary implant sizers

Muradian Filho, José 12 November 2007 (has links)
O procedimento cirúrgico para implantes mamários inclui os chamados medidores, utilizados para a mensuração de volume e geometria antes colocação do implante definitivo na paciente. Esses dispositivos são constituídos por um invólucro de elastômero de silicone grau médico da classe siloxano ou poliuretano e cheios com volumes pré-estabelecidos de gel ou elastômero de silicone, grau médico, sendo apresentados em diversos volumes e formas equivalentes ao volume e forma do implante correspondente. Este trabalho avaliou o processo de limpeza manual dos medidores para implantes, sob o ponto de vista da redução da carga microbiana, propiciando a eficácia do processo de esterilização, nas condições encontradas nos Centros Cirúrgicos Hospitalares e utilizando seus equipamentos usuais. Foram realizados testes de desafio microbiológico em amostras de medidores com superfície texturizada e superfície revestida com poliuretano, utilizando cinco microrganismos (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans e Aspergillus niger) e dois tipos de detergente para comparação: não enzimático e enzimático. Determinou-se a biocarga antes e após a limpeza, e em seguida realizou-se a esterilização a 126°C por 30 minutos (1,4 kgf/cm2) das amostras, que foi avaliada por teste de esterilidade. Os resultados mostraram que a etapa de lavagem contribuiu para a redução de 4 ciclos logarítmicos da população inicialmente considerada e não houve diferença entre os resultados de biocarga dos medidores com superfície texturizada e superfície revestida com poliuretano. O processo de limpeza dos medidores com detergente não enzimático ou enzimático seguido de esterilização apresenta eficiência suficiente para garantir a esterilidade requerida para a utilização dos medidores. / The surgical procedure for mammary implants include the so called sizers, used to measure both volume and geometry prior to the definitive placement in the womans breast. These devices present a silicon elastomer or polyurethane external capsule, medical grade, siloxan class filled with predetermined gel or silicon elastomer volumes, also medical grade and are presented in several shapes and volumes equivalent to the shapes and volumes of the corresponding final implant. This study evaluated the manual cleaning process of the sizers focusing in the bioburden thus rendering an effective sterilization process, under the usual equipment and conditions found in the hospital surgery centers. Microbial challenge tests were performed using 5 microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus niger) and two types of detergent , non enzymatic and enzymatic for comparison. Bioburden was determined before and after the cleaning procedure and after that samples were sterilized at 126°C (1,4 kgf/cm2) for 30 minutes, which was evaluated through sterility testing. Results shown that the cleaning step contributed to a 4 log cycle reduction in the samples initial bioburden and that there was no difference between bioburden results in both types of sizers (textured or polyurethane capsule). The cleaning process using non enzymatic or enzymatic detergents followed by sterilization shows enough effectiveness to ensure the required sterility for using the sizers.
39

Análise das complicações vasculares em receptores de transplante hepático intervivos

Steinbrück, Klaus January 2012 (has links)
Submitted by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-28T13:11:50Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) DISSERTAÇÃO KLAUS STEINBRUCK.pdf: 1704112 bytes, checksum: 061dda187540e95c23369cc5a57f8c98 (MD5) / Approved for entry into archive by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-28T13:12:05Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) DISSERTAÇÃO KLAUS STEINBRUCK.pdf: 1704112 bytes, checksum: 061dda187540e95c23369cc5a57f8c98 (MD5) / Made available in DSpace on 2017-09-28T13:12:05Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) DISSERTAÇÃO KLAUS STEINBRUCK.pdf: 1704112 bytes, checksum: 061dda187540e95c23369cc5a57f8c98 (MD5) Previous issue date: 2012 / Hospital Federal de Bonsucesso, Serviço de Cirurgia Hepato-Biliar / O objetivo deste estudo foi avaliar as complicações associadas às reconstruções vasculares nos receptores de Transplante Hepático Intervivos operados no Hospital Federal de Bonsucesso, no período de dezembro de 2001 e fevereiro de 2011. Foram levantados dados referentes aos receptores, seus respectivos doadores e relacionados ao procedimento cirúrgico, visando identificar possíveis fatores de risco ao desenvolvimento das complicações vasculares. Cento e quarenta e quatro transplantes foram realizados em 141 receptores, 76 adultos e 65 crianças. Foram identificadas sete complicações (4,9% do total) da artéria hepática, cinco complicações (3,5%) da veia porta e uma complicação (0,7%) da veia hepática. Devido ao pequeno número de complicações, não foi possível realizar análise estatística de fatores de risco. A sobrevida em um ano dos pacientes com e sem complicação vascular foi de 26% e 82%, respectivamente. A sobrevida em um ano dos enxertos utilizados em pacientes com e sem complicação vascular foi de 15% e 82%, respectivamente. Houve diferença estatística (p < 0,001) na sobrevida de pacientes e enxertos, que foi menor no grupo que apresentou complicações vasculares. Concluiu-se que as técnicas de reconstrução vascular utilizadas no Hospital Federal de Bonsucesso apresentam resultados comparáveis aos grandes centros internacionais. A presença de complicação na reconstrução vascular diminui a sobrevida do receptor e do enxerto / The objective of this study was to evaluate the complications associated with vascular reconstruction in recipients of living donor liver transplantation at Bonsucesso Federal Hospital, between December 2001 and February 2011. Data associated to recipients, their donors and surgical procedure were collected to identify possible risk factors for vascular complications development. One hundred and forty-four transplants were performed in 141 recipients, 76 adults and 65 children. We identified seven hepatic artery complications (4.9% of total), five complications (3.5%) of portal vein and one complication (0.7%) of hepatic vein. Due to the small number of complications, statistical analysis of risk factors could not be performed. The 1-year survival of patients with and without vascular complications was 26% and 82%, respectively. The 1-year survival of grafts in patients with and without vascular complications was 15% and 82%, respectively. There was statistical difference (p <0.001) on survival of patients and grafts, which was lower in the group with vascular complications. It was concluded that techniques used in vascular reconstruction at Bonsucesso Federal Hospital showed results comparable to major international centers. The presence of vascular complications in the reconstruction decreases survival of recipients and grafts
40

Avaliação do impacto do processo de limpeza na esterilização de medidores de implantes mamários / Assesment of the cleaning process impact in sterilization of mamary implant sizers

José Muradian Filho 12 November 2007 (has links)
O procedimento cirúrgico para implantes mamários inclui os chamados medidores, utilizados para a mensuração de volume e geometria antes colocação do implante definitivo na paciente. Esses dispositivos são constituídos por um invólucro de elastômero de silicone grau médico da classe siloxano ou poliuretano e cheios com volumes pré-estabelecidos de gel ou elastômero de silicone, grau médico, sendo apresentados em diversos volumes e formas equivalentes ao volume e forma do implante correspondente. Este trabalho avaliou o processo de limpeza manual dos medidores para implantes, sob o ponto de vista da redução da carga microbiana, propiciando a eficácia do processo de esterilização, nas condições encontradas nos Centros Cirúrgicos Hospitalares e utilizando seus equipamentos usuais. Foram realizados testes de desafio microbiológico em amostras de medidores com superfície texturizada e superfície revestida com poliuretano, utilizando cinco microrganismos (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans e Aspergillus niger) e dois tipos de detergente para comparação: não enzimático e enzimático. Determinou-se a biocarga antes e após a limpeza, e em seguida realizou-se a esterilização a 126°C por 30 minutos (1,4 kgf/cm2) das amostras, que foi avaliada por teste de esterilidade. Os resultados mostraram que a etapa de lavagem contribuiu para a redução de 4 ciclos logarítmicos da população inicialmente considerada e não houve diferença entre os resultados de biocarga dos medidores com superfície texturizada e superfície revestida com poliuretano. O processo de limpeza dos medidores com detergente não enzimático ou enzimático seguido de esterilização apresenta eficiência suficiente para garantir a esterilidade requerida para a utilização dos medidores. / The surgical procedure for mammary implants include the so called sizers, used to measure both volume and geometry prior to the definitive placement in the womans breast. These devices present a silicon elastomer or polyurethane external capsule, medical grade, siloxan class filled with predetermined gel or silicon elastomer volumes, also medical grade and are presented in several shapes and volumes equivalent to the shapes and volumes of the corresponding final implant. This study evaluated the manual cleaning process of the sizers focusing in the bioburden thus rendering an effective sterilization process, under the usual equipment and conditions found in the hospital surgery centers. Microbial challenge tests were performed using 5 microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus niger) and two types of detergent , non enzymatic and enzymatic for comparison. Bioburden was determined before and after the cleaning procedure and after that samples were sterilized at 126°C (1,4 kgf/cm2) for 30 minutes, which was evaluated through sterility testing. Results shown that the cleaning step contributed to a 4 log cycle reduction in the samples initial bioburden and that there was no difference between bioburden results in both types of sizers (textured or polyurethane capsule). The cleaning process using non enzymatic or enzymatic detergents followed by sterilization shows enough effectiveness to ensure the required sterility for using the sizers.

Page generated in 0.0681 seconds