• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 33
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 85
  • 85
  • 40
  • 14
  • 14
  • 12
  • 11
  • 11
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Valor prognóstico de provas funcionais na evolução tardia de pacientes com infarto agudo do miocárdio tratados com angioplastia coronária transluminal percutânea primária com implante de stent / Prognostic value of non-invasive functional tests during the follow-up of acute myocardial infarction treated with primary coronary stenting

Rica Dodo Delmar Büchler 25 June 2007 (has links)
Introdução: A angioplastia primária associada ao implante de stent é o tratamento de escolha no infarto agudo do miocárdio. Discute-se o valor de provas funcionais na abordagem de reestenose coronária, bem como o tempo ideal para sua realização. O objetivo deste estudo foi avaliar a importância do teste ergométrico, da cintilografia de perfusão miocárdica e do ecocardiograma bidimensional em repouso, no diagnóstico de reestenose em pacientes tratados durante as primeiras 12 horas de evolução do infarto com supra desnivelamento do segmento ST. Métodos: No período de agosto de 2003 a janeiro de 2006 foram selecionados 64 pacientes tratados com angioplastia primária e implante de stent nas primeiras 12 horas de evolução do primeiro infarto. Os pacientes realizaram ecocardiograma bidimensional em repouso, teste ergométrico com adição de derivações precordiais direitas e cintilografia de perfusão miocárdica com captação tomográfica (SPECT) sincronizada ao ECG (GATED SPECT), seis semanas (etapa1), seis meses (etapa 2) e um ano (etapa3) após a angioplastia primária. Foi realizado reestudo angiográfico no sexto mês de evolução. Resultados: A idade média foi 56,2 ±10,2 anos; 53 pacientes eram do sexo masculino. Doença uniarterial > = 50% foi observada em 46,9% dos casos. A artéria descendente anterior foi tratada em 48,4% dos pacientes, artéria coronária direita em 34,4%, artéria circunflexa em 10,9%, tronco de coronária esquerda em 3,1%,grande ramo diagonal em 1,6% e ponte safena em 1,6%. Reestenose angiográfica ocorreu em 28.8% dos 59 casos submetidos a reestudo. A fração de ejeção do ventrículo esquerdo ao ecocardiograma foi em média: 0,55 (etapa 1), 0,55 (etapa 2) e 0,56 (etapa 3). Observou-se diferença entre a fração de ejeção dos pacientes com e sem reestenose um ano após o procedimento (p=0,003). Sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia do teste ergométrico foram respectivamente: 53,3%, 69% , 38,1%, 80,6% e 64,9% na etapa 1 (p=0,123); 54,5%, 70,7%, 33,3%, 85,3% e 67,3% na etapa 2(p=0,159) e 38,5%, 66,7%, 27,8% ,76,5% e 59,6% na etapa 3 (p=0,747). A adição de derivações precordiais direitas não elevou os índices de sensibilidade em nenhuma das etapas. Os valores de sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácía obtidos após a cintilografia de perfusão miocárdica com MIBI, quando considerada a diferença de escores entre esforço e repouso >2, foram respectivamente 40%,78,6%, 40%, 78,6% e 68,4% na etapa1(p=0,185); 54,5%,87,8%,54,5%,87,8% e 80,8% na etapa 2 (p=0,006) e 25%,91,7%,50%,78,6% e 75% na etapa 3(p=0,156). Quando considerada a diferença de escores >4 os valores foram respectivamente: 13,3%,88,1%,28,6% ,74% e 68,4% na etapa 1(p>0,999); 36,4%,95,1%,66,7%,84,8% e 82,7% na etapa 2 (p=0,014) e 8,3%,94,4 %,33,3%,75,6% e 72,9 % na etapa 3 (p >0,999). Conclusões: O teste ergométrico não permitiu discriminar reestenose na população estudada, em nenhuma das etapas durante a evolução. A cintilografia miocárdica realizada seis meses após o infarto apresentou associação com reestenose. Os pacientes com reestenose apresentaram menores valores de fração de ejeção do ventrículo esquerdo um ano após a angioplastia primária, por avaliação ecocardiográfica. / Primary coronary angioplasty and stenting during acute myocardial infarction is the first treatment choice. Non-invasive testings have been used in the diagnosis of restenosis but its efficacy and time to be performed have to be determined. The purpose of this study was to evaluate exercise treadmill test, myocardial perfusion imaging and rest two-dimensional echocardiogram in the diagnosis of restenosis in patients treated during the first 12 hours of STelevation myocardial infarction.Methods: From August 2003 to January 2006, 64 patients were selected after primary coronary angioplasty and stenting. Rest two- dimensional echocardiogram, exercise treadmill test associated to right precordial leads and myocardial perfusion imaging according to GATED-SPECT were performed 6 weeks (step 1), 6 months (step 2) and one year (step 3) after the procedure.Coronary angiography was performed during the sixth month of follow-up.Results : Mean age was 56.2 ± 10.2 years; 53 patients were male. Single vessel disease > = 50% was observed in 46.9% of patients. The left anterior descending coronary artery was treated in 48.4%, the right coronary artery in 34.4%, the left circumflex in 10.9%, the left main coronary artery in 3.1%, a large diagonal branch in 1.6% and saphenous vein graft in 1.6% of the cases. Angiographic restenosis occurred in 28.8% from 59 patients submitted to coronary angiography. Mean left ventricular ejection fraction observed during rest two-dimensional echocardiogram was: 0.55 (step 1), 0.55 (step 2) and 0.56 (step 3). It was observed in patients with and without restenosis a significant difference in the left ventricular ejection fraction one year after the procedure (p= 0.003). Exercise treadmill test sensitivity, specificity, positive and negative predictive values and accuracy were respectively: 53.3%, 69%, 38.1%, 80.6% and 64.9% in step 1(p=0.123); 54.5%, 70.7%, 33.3%, 85.3% and 67.3% in step 2 (p=0.159) and 38.5%, 66.7%, 27.8%, 76.5% and 59.6% in step 3 (p=0.747). Right precordial leads did not show any additional significance. Sensitivity, specificity, positive and negative predictive values and accuracy during myocardial perfusion imaging when considering summed difference score > 2 were respectively: 40%, 78.6%, 40%, 78.6% and 68.4% in step 1(p=0.185); 54.5%, 87.8%, 54.5%,87.8% and 80.8% in step 2(p=0.006) and 25%, 91.7%, 50%, 78.6% and 75% in step 3(p=0.156). When considering summed difference score > 4 they were respectively: 13.3%, 88.1%, 28.6%, 74% and 68.4% in step 1(p> 0.999); 36.4%, 95.1%,66.7%, 84.8% and 82.7% in step 2 (p=0.014) and 8.3%, 94.4%, 33.3%, 75.6% and 72.9% in step 3(p> 0.999). Conclusions: Exercise treadmill test did not allow to discriminate restenosis in this population in all steps.Myocardial perfusion imaging performed 6 months after acute myocardial infarction was associated to restenosis. Patients with restenosis showed lower left ventricular ejection fraction one year after acute myocardial infarction by rest two-dimensional echocardiogram.
72

Use of a Technetium99m-Sestamibi Scan to Detect Ipsilateral Double Adenoma in a Patient With Primary Hyperparathyroidism: A Case Report

Gabriel, Joseph G., Contreras, Alejandro, Rosenthal, Andrew 01 January 2017 (has links)
INTRODUCTION: Patients with primary hyperparathyroidism generally have a single parathyroid adenoma that causes excessive excretion of parathyroid hormone. For about 2% to 15% of these patients, a double adenoma is present that involves one lesion on each side of the neck. CASE PRESENTATION: We describe a case of double parathyroid adenoma causing asymptomatic hypercalcemia. A presurgical technetium99m (Tc99m) sestamibi scan suggested an ipsilateral double adenoma in the left thyroid lobe. An intraoperative parathyroid hormone assay confirmed its successful removal. DISCUSSION: Although double adenomas are not yet widely acknowledged, presurgical imaging and nuclear scans can help to localize multiple lesions, and intraoperative parathyroid hormone assays can confirm the diagnosis and cure.
73

Rodent FDG-PET imaging for the pre-clinical assessment of novel glioma therapies

Assadian, Sarah January 2007 (has links)
No description available.
74

Comparação entre a estratificação clínica e a cintilografia de perfusão miocárdica como preditores de eventos cardiovasculares em candidatos a transplante renal / Comparison between clinical stratification and myocardial perfusion scintigraphy as a predictor of cardiovascular events in kidney transplant candidates

Arantes, Rodolfo Leite 18 September 2009 (has links)
A doença cardiovascular (DCV) é uma condição clínica comum entre pacientes (pcts) portadores de doença renal crônica (DRC) e é causa de eventos fatais observados peri transplante renal (TX). A melhor estratégia de avaliação cardiovascular em candidatos a transplante (CTR) ainda é controversa.Ignora-se se todos os pacientes devem ser submetidos a testes não-invasivos/invasivos ou se estes devem ser reservados aqueles com determinadas características clínicas, como população geral. O objetivo deste estudo foi comparar a estratificação de risco baseada em método nãoinvasivo de detecção de doença coronária com dois métodos de estratificação clínica de risco cardiovascular preconizados pela American Society of Transplantation (AST) e European Renal Association (ERA). A AST subdivide os pcts em : alto risco (idade maior ou igual a 50 anos e/ou diabete e/ou DCV clínica) e baixo risco (os demais). A ERA subdivide em: alto risco (DCV clínica), risco intermediário (diabéticos e/ou idade maior ou igual a 50 anos) e baixo risco (os demais). Nós estudamos 386 pcts com DRC em diálise enviados ao nosso serviço para avaliação cardiovascular antes da inclusão na lista de espera de TX. Foram estratificados quanto ao risco de eventos de acordo com os dois algoritmos acima e alterações na cintilografia de perfusão miocárdica (SPECT-MIBI) com dipiridamol e acompanhados até a morte, TX ou ocorrência de eventos. A estratificação clínica (RR:1,8 [IC95% 1,3 2,6- P<0,0001] e o SPECT-MIBI (RR:1,5 [IC95% 1,2-1,9-P=0,002] identificaram os pcts de maior risco de eventos cardiovasculares . Apenas os pcts ASTalto risco (RR1,4 [IC95%1,1-1,8-P=0,002] e ERA médio risco com SPECTMIBI alterado (RR:1,7 [IC95% 1,2-2,3-P=0,003] tiveram maior incidência de eventos. Os pcts de baixo risco pelos dois algorítmos de estratificação clínica (P=0,50) e do sistema ERA alto risco (RR:1,1 [IC95% 0,8-1,5-P=0,41], não se beneficiaram dos resultados do estudo não-invasivo. Concluímos que os estudos não-invasivos não devem ser utilizados em todos os CTR mas devem ser reservados aos pcts previamente identificados pela estratificação clínica de risco. Esses resultados permitem uma abordagem mais racional da avaliação pré- TX com melhor uso dos recursos econômicos escassos. / Cardiovascular (CV) disease is a common condition in chronic kidney disease (CKD) patients and is the leading cause of fatal events during and after renal transplantation. The best strategy for CV evaluation and coronary risk stratification in renal transplant candidates remains controversial. Moreover, there is no consensus regarding the best strategy for detection of coronary artery disease (CAD). We still do not know if all patients should be evaluated by noninvasive testing or if this approach should be restricted to individuals with clinical evidence of CAD, as in the general population. The objective of this study was to compare CV risk stratification based on nonivasive testing for CAD with two clinical stratification methods as advanced by The American Society of Transplantation (AST) and by The European Renal Association (ERA), respectively. The AST divides patients in high risk (age50 years and/or diabetes and/or CV disease) and low risk (all others).The ERA divides : high risk (CV disease), intermediate risk (age 50 years and/or diabetes), and low risk (as above). We studied 386 CKD patients treated by hemodyalisis, to CV evaluation before being admitted to the renal transplant waiting list. All patients were stratified for the risk of future major cardiovascular events (MACE) using the clinical algorithms and also by myocardial scintigraphy (SPECT-MIBI) with dipyridamol and followedup until death, transplant or MACE. Clinical algorithms (RR:1,8 [IC95% 1,3 2,6-P<0,0001] and SPECT-MIBI(RR:1,5 [IC95% 1,2-1,9-P=0,002] identified patients at increased risk of events. The combined use of clinical stratification followed by SPECT showed that the only patients that would benefit from SPECT risk stratification were those belonging the AST-high risk (RR1,4 [IC95%1,1-1,8-P=0,002] and ERA-intermediate risk groups (RR:1,7 [IC95% 1,2-2,3-P=0,003]. In all other groups :ERA-high-risk (RR:1,1[IC95% 0,8-1,5- P=0,41] and ERA and AST-low-risk (P=0,50) SPECT did not add to the probability of events defined by clinical stratification alone. We conclude that SPECT should not be applied to all renal transplant candidates but should be restricted to those considered at a category of risk as defined by clinical algorithms. These results delineate a more rational approach to risk stratification in renal transplant candidates with a better utilization of economical resources.
75

"Avaliação da função renal com estudos radioisotópicos (DTPA-99mTc, DMSA-99mTc e EC-99mTc) em pacientes submetidos à quimioterapia com agentes nefrotóxicos" / Radioisotopic evaluation of renal function with 99mTc-DTPA, 99mTc-DMSA and 99mTc-EC in patients underwent chemotherapy with nephrotoxic agents

Benedita Andrade Leal de Abreu 06 April 2006 (has links)
Pacientes com diagnósticos oncológicos diversos sob terapia com agentes nefrotóxicos, foram avaliados através de procedimentos radioisotópicos, em três momentos diferentes. Os achados radioisotópicos foram comparados com as avaliações laboratoriais rotineiras. Não mostraram alterações estatisticamente significativas os seguintes parâmetros: uréia, creatinina, sedimentos anormais e índice de Crockoft-Gault. Concluiu-se que a avaliação da função renal com os métodos rotineiramente utilizados na prática oncológica não foram estatisticamente significativas. Dentre os estudos utilizando radionuclídeos, o DTPA-99mTc e DMSA-99mTc, evidenciaram alterações, enquanto o EC-99mTc, não as detectou / Patients with different oncologic diagnoses under treatment with nephrotoxic drugs were evaluated by radioisotopic agents at three different moments. Radioisotopic data were compared with biochemical routine tests. Concerning laboratorial parameters like serum creatinine, urea and Cockroft Gault index, no statistically significant changes were observed. Possible to conclude that renal function evaluation with methods routinely used in oncological practice did not reveal any statistically significant change. Radioisotopic studies using 99mTc-DTPA and 99mTc-DMSA showed considerable alterations, however with 99mTc-EC no significant changes were evidenced
76

Considerações referentes à influência do posicionamento dos membros superiores sobre o resultado da cintilografia de perfusão do miocárdio / Considerations about the influence of upper arms positioning on myocardial perfusion scintigraphy results

Izaki, Marisa 01 August 2008 (has links)
I NTRODUÇÃO: Na cintilografia de perfusão do miocárdio, contrariamente ao desenvolvimento tecnológico ao longo do tempo, manteve-se desde o princípio a mesma forma, por vezes desconfortável ou mesmo inviável, de posicionamento na aquisição das imagens: decúbito dorsal com os braços elevados. OBJETIVOS: O objetivo da pesquisa foi o de avaliar se na aquisição da cintilografia de perfusão do miocárdio o posicionamento com os membros superiores abaixados(T) apresenta os mesmos resultados que os obtidos com os membros superiores elevados(C), tanto em termos de alterações perfusionais como em relação aos parâmetros funcionais. . MÉTODOS: Foram estudados 120 pacientes, 83 (69%) do sexo masculino, com idade 59,4 ± 11,4 anos e peso 72,8 ± 14 kg. Foi realizada primeiramente a aquisição C e na seqüência a aquisição T, utilizando protocolo de um dia de repouso-estresse (dose 370 MBq e 1110 MBq de sestamibi-99mTc), com estresse sincronizado ao eletrocardiograma (gated- SPECT). Três modelos distintos de equipamentos de dois detectores foram utilizados no estudo. Os estudos foram processados usando reconstrução iterativa (OSEM). Na interpretação foi utilizado o modelo de segmentação miocárdica de 17 segmentos, pontuados de 0 a 4 (normal a ausente) segundo o grau de captação. Baseada na análise de um observador dentre um grupo de sete, foi realizada a comparação da totalidade dos segmentos e também segmento a segmento das aquisições C e T nas etapas de estresse e de repouso. Foi comparada também a somatória das pontuações das etapas de estresse(SSS) e repouso(SRS). Os pacientes foram divididos segundo dois critérios: primeiramente, normais (SSS=0) e anormais (SSS>1) e posteriormente, em de baixo risco (SSS3) e de maior risco (SSS>3) A comparação dos parâmetros funcionais de fração de ejeção do ventrículo esquerdo (FEVE), volume diastólico final (VDF), volume sistólico final(VSF), somatória dos escores de motilidade (SMS) e somatória dos escores de espessamento (STS) foi baseada nos valores obtidos de modo automático utilizando o programa computacional Quantitative Gated SPECT. RESULTADOS: No modo C, 23,3% dos pts referiram algum grau de dor no membro superior ou no ombro e no modo T 5 %. Houve diferença significativa (p<0,05) na comparação dos 2040 segmentos miocárdicos entre C e T, ao estresse e ao repouso. Nos 63 pts normais não houve diferença significativa dos escores entre C e T ao estresse e ao repouso. O mesmo foi observado nos 80 pts de baixo risco. Nos 57 pts anormais houve boa correlação entre os valores de SSS (Rho=0,93, p=0,0001) e SRS (Rho=0,93, p=0,0001), mas com valores não equivalentes (p<0,05), sendo a média dos valores de SSS (9,28±8,10) e SRS (7,89±7,34) da aquisição T inferiores à média dos valores de SSS (10,07±7,71) e SRS (8,46±7,35) encontrada na aquisição C. Nos 40 pts de risco, houve boa correlação dos valores de SSS(Rho=0,95, p=0,0001) e SRS(Rho=0,96 p=0,0001), porém a média dos valores de SSS (12,53±7,54) e SRS (10,60±7,08) da aquisição T foi significantemente (p<0,05) inferior à média dos valores de SSS (13,43±6,81) e SRS(11,33±6,97) encontrados na aquisição C. Os parâmetros funcionais apresentaram boa correlação entre C e T, exceto o VDF(p=0,0001). CONCLUSÕES: Os modos C e T apresentam boa correlação dos parâmetros funcionais, exceto o VDF. Embora a aquisição T tenha sido um pouco mais confortável e tenha demonstrado boa correlação nos achados perfusionais, em pts anormais e de maior risco há tendência à subestimação dos defeitos perfusionais. Considerando a importância da medida precisa da intensidade e extensão das alterações perfusionais em termos de avaliação prognostica e decisão terapêutica, a aquisição com membro superior abaixado deve ser evitada. Em situações onde a aquisição com membros superiores abaixados é a única alternativa, os resultados da cintilografia devem ser interpretados com cuidado, especialmente em pacientes anormais e de maior risco, onde as alterações podem estar subestimadas / Contrary to the advances in imaging technology for nuclear cardiology applications, we keep using the same often uncomfortable and sometimes impracticable patient position- supine with arms raised above the head (C). We tested another position modality: supine with arms down at the sides of the trunk (T). The purpose of this study was to verify if the functional and perfusion results of the acquisition T are equivalent to those of the acquisition mode C. We studied 120 patients (pts), 83 (69%) male, aged 59.4±11.4 years and weighting 72.8±14 kg. We performed a one-day protocol (rest gated/stress), using 99mTc-sestamibi (370 MBq and 1110 MBq). In both times (rest and stress), we first performed acquisition in C and in sequence the acquisition in T. The studies were performed in three types of dual detector SPECT systems. T mode was executed successfully in all pts. Images were processed by the iterative reconstruction method (OSEM). Each study was independently interpreted by one nuclear medicine specialist from a group of seven physicians using the 17-segment model. The segments were scored using a 5-point model ranging from 0 (normal uptake) to 4 (uptake absent). The total score of the left ventricle at stress is referred to as the summed stress score (SSS) and at rest as the summed rest score (SRS). The patients were categorized in subgroups by two criteria: normal (SSS=0) or abnormal (SSS1) and low risk (SSS3) or risk (SSS>3). The values of the functional parameters of left ventricular ejection fraction (LVEF), end diastolic volume (EDV), end systolic volume (ESV), stress motion score (SMS) and stress thickening score (STS) for both C and T were automatically obtained by the quantitative gated SPECT (QGS) program and results were compared. Shoulder and/or back pain occurred in 23.3% of C patients and in 5% of T patients. There was no agreement between the 2040 segmental scores of both rest and stress in C and T modes (p<0.05). No significant differences between C and T were found for SSS and SRS in the 63 normal individuals nor in the 80 low risk patients. Good correlation between C and T was found for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001) in the 57 abnormal pts, but the mean SSS (9.28±8.10) and SRS (7.89±7.34) values of T were significantly lower (p<0.05) than the mean for SSS (10.07±7,71) and SRS(8.46±7,35) of C mode. Similar patterns were observed in the 40 risk pts; good correlation was found between C and T modes for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001), but the mean SSS (12.53±7.54) and SRS (10.60±7.08) values of T were significantly lower (p<0.05) than SSS (13.43±6.81) and SRS (11.33±6.97) of C mode. Good correlation between C and T was found for all functional parameters, except for EDV (p=0.0001). Although T mode appears to be more comfortable and presented a good correlation between SSS and SRS values, in abnormal and risk pts, the extent and severity of defects can be underestimated. Considering the important therapeutic and prognostic implications of an accurate perfusion measurement, the cardiac SPECT acquisition with the arms in down position should be avoided. When arms-down acquisition is the only alternative, scintigraphy results must be carefully interpreted, especially in abnormal scans whereas the amount of perfusion abnormalities can be underestimated.
77

"Avaliação da função renal com estudos radioisotópicos (DTPA-99mTc, DMSA-99mTc e EC-99mTc) em pacientes submetidos à quimioterapia com agentes nefrotóxicos" / Radioisotopic evaluation of renal function with 99mTc-DTPA, 99mTc-DMSA and 99mTc-EC in patients underwent chemotherapy with nephrotoxic agents

Abreu, Benedita Andrade Leal de 06 April 2006 (has links)
Pacientes com diagnósticos oncológicos diversos sob terapia com agentes nefrotóxicos, foram avaliados através de procedimentos radioisotópicos, em três momentos diferentes. Os achados radioisotópicos foram comparados com as avaliações laboratoriais rotineiras. Não mostraram alterações estatisticamente significativas os seguintes parâmetros: uréia, creatinina, sedimentos anormais e índice de Crockoft-Gault. Concluiu-se que a avaliação da função renal com os métodos rotineiramente utilizados na prática oncológica não foram estatisticamente significativas. Dentre os estudos utilizando radionuclídeos, o DTPA-99mTc e DMSA-99mTc, evidenciaram alterações, enquanto o EC-99mTc, não as detectou / Patients with different oncologic diagnoses under treatment with nephrotoxic drugs were evaluated by radioisotopic agents at three different moments. Radioisotopic data were compared with biochemical routine tests. Concerning laboratorial parameters like serum creatinine, urea and Cockroft Gault index, no statistically significant changes were observed. Possible to conclude that renal function evaluation with methods routinely used in oncological practice did not reveal any statistically significant change. Radioisotopic studies using 99mTc-DTPA and 99mTc-DMSA showed considerable alterations, however with 99mTc-EC no significant changes were evidenced
78

Comparação entre a estratificação clínica e a cintilografia de perfusão miocárdica como preditores de eventos cardiovasculares em candidatos a transplante renal / Comparison between clinical stratification and myocardial perfusion scintigraphy as a predictor of cardiovascular events in kidney transplant candidates

Rodolfo Leite Arantes 18 September 2009 (has links)
A doença cardiovascular (DCV) é uma condição clínica comum entre pacientes (pcts) portadores de doença renal crônica (DRC) e é causa de eventos fatais observados peri transplante renal (TX). A melhor estratégia de avaliação cardiovascular em candidatos a transplante (CTR) ainda é controversa.Ignora-se se todos os pacientes devem ser submetidos a testes não-invasivos/invasivos ou se estes devem ser reservados aqueles com determinadas características clínicas, como população geral. O objetivo deste estudo foi comparar a estratificação de risco baseada em método nãoinvasivo de detecção de doença coronária com dois métodos de estratificação clínica de risco cardiovascular preconizados pela American Society of Transplantation (AST) e European Renal Association (ERA). A AST subdivide os pcts em : alto risco (idade maior ou igual a 50 anos e/ou diabete e/ou DCV clínica) e baixo risco (os demais). A ERA subdivide em: alto risco (DCV clínica), risco intermediário (diabéticos e/ou idade maior ou igual a 50 anos) e baixo risco (os demais). Nós estudamos 386 pcts com DRC em diálise enviados ao nosso serviço para avaliação cardiovascular antes da inclusão na lista de espera de TX. Foram estratificados quanto ao risco de eventos de acordo com os dois algoritmos acima e alterações na cintilografia de perfusão miocárdica (SPECT-MIBI) com dipiridamol e acompanhados até a morte, TX ou ocorrência de eventos. A estratificação clínica (RR:1,8 [IC95% 1,3 2,6- P<0,0001] e o SPECT-MIBI (RR:1,5 [IC95% 1,2-1,9-P=0,002] identificaram os pcts de maior risco de eventos cardiovasculares . Apenas os pcts ASTalto risco (RR1,4 [IC95%1,1-1,8-P=0,002] e ERA médio risco com SPECTMIBI alterado (RR:1,7 [IC95% 1,2-2,3-P=0,003] tiveram maior incidência de eventos. Os pcts de baixo risco pelos dois algorítmos de estratificação clínica (P=0,50) e do sistema ERA alto risco (RR:1,1 [IC95% 0,8-1,5-P=0,41], não se beneficiaram dos resultados do estudo não-invasivo. Concluímos que os estudos não-invasivos não devem ser utilizados em todos os CTR mas devem ser reservados aos pcts previamente identificados pela estratificação clínica de risco. Esses resultados permitem uma abordagem mais racional da avaliação pré- TX com melhor uso dos recursos econômicos escassos. / Cardiovascular (CV) disease is a common condition in chronic kidney disease (CKD) patients and is the leading cause of fatal events during and after renal transplantation. The best strategy for CV evaluation and coronary risk stratification in renal transplant candidates remains controversial. Moreover, there is no consensus regarding the best strategy for detection of coronary artery disease (CAD). We still do not know if all patients should be evaluated by noninvasive testing or if this approach should be restricted to individuals with clinical evidence of CAD, as in the general population. The objective of this study was to compare CV risk stratification based on nonivasive testing for CAD with two clinical stratification methods as advanced by The American Society of Transplantation (AST) and by The European Renal Association (ERA), respectively. The AST divides patients in high risk (age50 years and/or diabetes and/or CV disease) and low risk (all others).The ERA divides : high risk (CV disease), intermediate risk (age 50 years and/or diabetes), and low risk (as above). We studied 386 CKD patients treated by hemodyalisis, to CV evaluation before being admitted to the renal transplant waiting list. All patients were stratified for the risk of future major cardiovascular events (MACE) using the clinical algorithms and also by myocardial scintigraphy (SPECT-MIBI) with dipyridamol and followedup until death, transplant or MACE. Clinical algorithms (RR:1,8 [IC95% 1,3 2,6-P<0,0001] and SPECT-MIBI(RR:1,5 [IC95% 1,2-1,9-P=0,002] identified patients at increased risk of events. The combined use of clinical stratification followed by SPECT showed that the only patients that would benefit from SPECT risk stratification were those belonging the AST-high risk (RR1,4 [IC95%1,1-1,8-P=0,002] and ERA-intermediate risk groups (RR:1,7 [IC95% 1,2-2,3-P=0,003]. In all other groups :ERA-high-risk (RR:1,1[IC95% 0,8-1,5- P=0,41] and ERA and AST-low-risk (P=0,50) SPECT did not add to the probability of events defined by clinical stratification alone. We conclude that SPECT should not be applied to all renal transplant candidates but should be restricted to those considered at a category of risk as defined by clinical algorithms. These results delineate a more rational approach to risk stratification in renal transplant candidates with a better utilization of economical resources.
79

Considerações referentes à influência do posicionamento dos membros superiores sobre o resultado da cintilografia de perfusão do miocárdio / Considerations about the influence of upper arms positioning on myocardial perfusion scintigraphy results

Marisa Izaki 01 August 2008 (has links)
I NTRODUÇÃO: Na cintilografia de perfusão do miocárdio, contrariamente ao desenvolvimento tecnológico ao longo do tempo, manteve-se desde o princípio a mesma forma, por vezes desconfortável ou mesmo inviável, de posicionamento na aquisição das imagens: decúbito dorsal com os braços elevados. OBJETIVOS: O objetivo da pesquisa foi o de avaliar se na aquisição da cintilografia de perfusão do miocárdio o posicionamento com os membros superiores abaixados(T) apresenta os mesmos resultados que os obtidos com os membros superiores elevados(C), tanto em termos de alterações perfusionais como em relação aos parâmetros funcionais. . MÉTODOS: Foram estudados 120 pacientes, 83 (69%) do sexo masculino, com idade 59,4 ± 11,4 anos e peso 72,8 ± 14 kg. Foi realizada primeiramente a aquisição C e na seqüência a aquisição T, utilizando protocolo de um dia de repouso-estresse (dose 370 MBq e 1110 MBq de sestamibi-99mTc), com estresse sincronizado ao eletrocardiograma (gated- SPECT). Três modelos distintos de equipamentos de dois detectores foram utilizados no estudo. Os estudos foram processados usando reconstrução iterativa (OSEM). Na interpretação foi utilizado o modelo de segmentação miocárdica de 17 segmentos, pontuados de 0 a 4 (normal a ausente) segundo o grau de captação. Baseada na análise de um observador dentre um grupo de sete, foi realizada a comparação da totalidade dos segmentos e também segmento a segmento das aquisições C e T nas etapas de estresse e de repouso. Foi comparada também a somatória das pontuações das etapas de estresse(SSS) e repouso(SRS). Os pacientes foram divididos segundo dois critérios: primeiramente, normais (SSS=0) e anormais (SSS>1) e posteriormente, em de baixo risco (SSS3) e de maior risco (SSS>3) A comparação dos parâmetros funcionais de fração de ejeção do ventrículo esquerdo (FEVE), volume diastólico final (VDF), volume sistólico final(VSF), somatória dos escores de motilidade (SMS) e somatória dos escores de espessamento (STS) foi baseada nos valores obtidos de modo automático utilizando o programa computacional Quantitative Gated SPECT. RESULTADOS: No modo C, 23,3% dos pts referiram algum grau de dor no membro superior ou no ombro e no modo T 5 %. Houve diferença significativa (p<0,05) na comparação dos 2040 segmentos miocárdicos entre C e T, ao estresse e ao repouso. Nos 63 pts normais não houve diferença significativa dos escores entre C e T ao estresse e ao repouso. O mesmo foi observado nos 80 pts de baixo risco. Nos 57 pts anormais houve boa correlação entre os valores de SSS (Rho=0,93, p=0,0001) e SRS (Rho=0,93, p=0,0001), mas com valores não equivalentes (p<0,05), sendo a média dos valores de SSS (9,28±8,10) e SRS (7,89±7,34) da aquisição T inferiores à média dos valores de SSS (10,07±7,71) e SRS (8,46±7,35) encontrada na aquisição C. Nos 40 pts de risco, houve boa correlação dos valores de SSS(Rho=0,95, p=0,0001) e SRS(Rho=0,96 p=0,0001), porém a média dos valores de SSS (12,53±7,54) e SRS (10,60±7,08) da aquisição T foi significantemente (p<0,05) inferior à média dos valores de SSS (13,43±6,81) e SRS(11,33±6,97) encontrados na aquisição C. Os parâmetros funcionais apresentaram boa correlação entre C e T, exceto o VDF(p=0,0001). CONCLUSÕES: Os modos C e T apresentam boa correlação dos parâmetros funcionais, exceto o VDF. Embora a aquisição T tenha sido um pouco mais confortável e tenha demonstrado boa correlação nos achados perfusionais, em pts anormais e de maior risco há tendência à subestimação dos defeitos perfusionais. Considerando a importância da medida precisa da intensidade e extensão das alterações perfusionais em termos de avaliação prognostica e decisão terapêutica, a aquisição com membro superior abaixado deve ser evitada. Em situações onde a aquisição com membros superiores abaixados é a única alternativa, os resultados da cintilografia devem ser interpretados com cuidado, especialmente em pacientes anormais e de maior risco, onde as alterações podem estar subestimadas / Contrary to the advances in imaging technology for nuclear cardiology applications, we keep using the same often uncomfortable and sometimes impracticable patient position- supine with arms raised above the head (C). We tested another position modality: supine with arms down at the sides of the trunk (T). The purpose of this study was to verify if the functional and perfusion results of the acquisition T are equivalent to those of the acquisition mode C. We studied 120 patients (pts), 83 (69%) male, aged 59.4±11.4 years and weighting 72.8±14 kg. We performed a one-day protocol (rest gated/stress), using 99mTc-sestamibi (370 MBq and 1110 MBq). In both times (rest and stress), we first performed acquisition in C and in sequence the acquisition in T. The studies were performed in three types of dual detector SPECT systems. T mode was executed successfully in all pts. Images were processed by the iterative reconstruction method (OSEM). Each study was independently interpreted by one nuclear medicine specialist from a group of seven physicians using the 17-segment model. The segments were scored using a 5-point model ranging from 0 (normal uptake) to 4 (uptake absent). The total score of the left ventricle at stress is referred to as the summed stress score (SSS) and at rest as the summed rest score (SRS). The patients were categorized in subgroups by two criteria: normal (SSS=0) or abnormal (SSS1) and low risk (SSS3) or risk (SSS>3). The values of the functional parameters of left ventricular ejection fraction (LVEF), end diastolic volume (EDV), end systolic volume (ESV), stress motion score (SMS) and stress thickening score (STS) for both C and T were automatically obtained by the quantitative gated SPECT (QGS) program and results were compared. Shoulder and/or back pain occurred in 23.3% of C patients and in 5% of T patients. There was no agreement between the 2040 segmental scores of both rest and stress in C and T modes (p<0.05). No significant differences between C and T were found for SSS and SRS in the 63 normal individuals nor in the 80 low risk patients. Good correlation between C and T was found for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001) in the 57 abnormal pts, but the mean SSS (9.28±8.10) and SRS (7.89±7.34) values of T were significantly lower (p<0.05) than the mean for SSS (10.07±7,71) and SRS(8.46±7,35) of C mode. Similar patterns were observed in the 40 risk pts; good correlation was found between C and T modes for SSS (Rho=0.95, p=0.0001) and SRS (Rho=0.96 p=0.0001), but the mean SSS (12.53±7.54) and SRS (10.60±7.08) values of T were significantly lower (p<0.05) than SSS (13.43±6.81) and SRS (11.33±6.97) of C mode. Good correlation between C and T was found for all functional parameters, except for EDV (p=0.0001). Although T mode appears to be more comfortable and presented a good correlation between SSS and SRS values, in abnormal and risk pts, the extent and severity of defects can be underestimated. Considering the important therapeutic and prognostic implications of an accurate perfusion measurement, the cardiac SPECT acquisition with the arms in down position should be avoided. When arms-down acquisition is the only alternative, scintigraphy results must be carefully interpreted, especially in abnormal scans whereas the amount of perfusion abnormalities can be underestimated.
80

Pacientes com carcinoma papilífero de tireoide tratados com tireoidectomia total e não submetidos a dose ablativa com iodo radioativo: evolução da captação cervical do iodo radioativo e da tireoglobulina / Evolution of cervical radioactive iodine uptake and serum thyroglobulin after total thyroidectomy for the treatment of papillary thyroid carcinoma without radioiodine remnant ablation

Cardoso, Cesar Augusto 06 August 2013 (has links)
INTRODUÇÃO: O tratamento e o seguimento do carcinoma papilífero de tireoide (CPT) são individualizados pelos riscos de recorrência e mortalidade. A indicação do iodo radioativo (iodo-131) para ablação de remanescente tireóideo captante é controversa em casos classificados como de baixo risco. Por diminuir a massa tireóidea remanescente, a dose ablativa com iodo-131 (DAIR) facilita o seguimento pós-operatório, mas tem riscos e onera o tratamento. Não se encontrou na literatura estudo demonstrando a evolução da captação cervical do iodo-131 e da concentração sérica de tireoglobulina (TG) em pacientes submetidos à tireoidectomia total por CPT de riscos muito baixo e baixo, sem DAIR. OBJETIVO: Avaliar a evolução da captação cervical do iodo-131 e da concentração sérica de TG em pacientes com CPT de baixo e muito baixo risco, após tireoidectomia total e não submetidos a DAIR. MÉTODOS: Foi realizado estudo prospectivo não randomizado em pacientes com CPT de baixo e muito baixo risco submetidos a tireoidectomia total, atendidos no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo no período setembro de 2008 novembro de 2011. Após a tireoidectomia foi ministrada levotiroxina na dose necessária para manter a concentração de hormônio tireo-estimulante (TSH) entre 0,5 e 1,0 U/ml. Dosagem sérica de TG, pesquisa de corpo inteiro com iodo-131 (PCI) e dosagem de iodo urinário foram realizadas sob estímulo de TSH endógeno elevado por interrupção da reposição hormonal com levotiroxina, por 30 dias, e dieta pobre em iodo por 15 dias. Foram realizadas ultrassonografias cervicais três e 12 meses após a tireoidectomia. As concentrações séricas de TSH e tiroxina livre sem supressão do TSH foram realizadas seis, nove e 12 meses após a tireoidectomia. RESULTADOS: Dos 26 pacientes incluídos, 22 eram do sexo feminino (84,6%), e quatro, do masculino (15,4%), com idade variando de 27 a 45 anos (média de 38,5 anos e mediana de 39,5 anos). Onze pacientes (42,3%) foram estratificados como de muito baixo risco, e 15 (57,7%), como de baixo risco. Todos os pacientes estavam em hipotireoidismo, no momento da avaliação inicial e final (TSH > 30?U/ml), e os exames realizados seis, nove e 12 meses após a operação, com ingestão de levotiroxina, mostraram as medianas da concentração de TSH de 3,4 ?U/mL, 0,3 ?U/mL e 1,5 ?U/mL, respectivamente. A média da captação de iodo-131 caiu de 1,9% na avaliação inicial para 0,5% na final, e a média da concentração sérica de TG estimulada caiu de 3,1 ng/mL para 1,9 ng/ml. CONCLUSÃO: Houve diminuição estatisticamente significativa da captação cervical do iodo-131 e da concentração sérica de TG sem DAIR nos pacientes submetidos a tireoidectomia total por CPT de baixo e muito baixo risco, sem supressão do TSH / INTRODUCTION: The treatment and follow-up of papillary thyroid carcinoma (PTC) are individualized according to the risk of recurrence and mortality. Radioiodine ablation of thyroid remnant is controversial in low-risk patients. By reducing the thyroid remnant, ablation with radioiodine facilitates the follow-up, but it adds risks and increases the cost of the treatment. We found no published study showing the outcome of cervical uptake of radioactive iodine and the serum concentration of thyroglobulin (TG) in patients undergoing total thyroidectomy for PTC classified as very low risk and low risk who did not undertake ablative dose of radioactive iodine. OBJECTIVE: The aim of this study was to document changes in the cervical uptake of radioiodine and changes in TG concentrations in low-risk and very low-risk PTC patients not submitted to radioiodine remnant ablation (RRA). METHODS: We conducted a prospective non-randomized study in patients with PTC classified as low risk and very low risk undergoing total thyroidectomy at the General Hospital of the University of Sao Paulo, School of Medicine, from September 2008 to November 2011. Levothyroxine was administered after thyroidectomy at a dose required to maintain the concentration of thyroid stimulating hormone (TSH) between 0.5 and 1.0 ?U/ml. Serum thyroglobulin, whole body scan with iodine-131 and urinary iodine were evaluated under high endogenous TSH stimulation after 30 days levothyroxine withdrawal and iodine-poor diet for 15 days. Neck ultrasounds were performed three and 12 months after thyroidectomy. The concentration of serum TSH and free thyroxine without TSH suppression were measured six, nine and 12 months after thyroidectomy. RESULTS: Of the 26 patients included, 22 were female (84.6%) and four were male (15.4%), aged ranged from 27 to 45 years (mean 38.5 years, median 39.5 years). Eleven patients (42.3%) were classified as very low risk and 15 (57.7%) as low risk. All subjects were hypothyroidism at the time of the initial and final evaluations (TSH> 30 ?U/ml). Tests performed six, nine and 12 months after the operation with levothyroxine showed the median concentration of TSH 3.4 ?U/ml, 0.3 U/ml and 1.5 ?U/ml, respectively. The average uptake of iodine-131 dropped 1.9% at baseline to the end of 1.5% and higher mean serum thyroglobulin fell from 3.1 ng/mL to 1.9 ng/ml. CONCLUSION: There was a statistically significant reduction in cervical radioiodine uptake and in stimulated TG level over one year\'s observation of low-risk and very low-risk papillary thyroid carcinoma patients who were not treated with RRA, even in the absence of TSH suppression

Page generated in 0.1283 seconds