• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 137
  • 26
  • 22
  • 9
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 219
  • 129
  • 58
  • 56
  • 53
  • 47
  • 38
  • 37
  • 36
  • 32
  • 30
  • 29
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da resistência das vias aéreas através da técnica do interruptor em pacientes com fibrose cística

Rocha, Alessandra January 2010 (has links)
Estudos para a avaliação da resistência das vias aéreas de pré-escolares com fibrose cística através da técnica do interruptor (Rint) são escassos. Foi realizado um estudo tranversal, com 38 pacientes acompanhados no ambulatório de Fibrose Cística do Hospital São Lucas da Pontifícia Universidade Católica do Rio Grande do Sul. Foram realizadas medida da Rint, seguida da avaliação espirométrica em todos os pacientes, repetindo os testes após o uso de salbutamol para a aferição da resposta ao broncodilatador. Nos resultados, foram encontradas forte correlação entre o inverso da Rint e o volume expiratório forçado no 1º segundo (VEF1), (r=0,8 p<0,001) e moderadas correlações entre o inverso da Rint e o fluxo expiratório forçado entre 25% e 75% da capacidade vital (FEF 25-75), (r=0,74 p<0,001) e entre o inverso da Rint e o índice de massa corporal (IMC), (r=0,62 p<0,001). A acurácia da avaliação da resposta ao broncodilatador pela Rint, foi testada através da curva ROC (Receiver Operator Characteristic Curve),comparando-se com resposta ao broncodilatador na espirometria. Foi obtida uma área de 0,75 para o ponto de corte de -28%, correspondendo a uma sensibilidade de 66% e uma especificidade de 82%. Os achados indicam que a Rint apresenta boa correlação com a espirometria, no entanto a técnica não possui uma acurácia suficiente para substituir a Espirometria na avaliação da resposta ao broncodilatador. / Few studies have been published on airway resistance measurements using the interrupter technique (IT). We performed a cross-sectional study, evaluating 38 children and adolescents with Cystic Fibrosis (CF), followed at the outpatient CF clinic of Hospital São Lucas from Pontifícia Universidade Católica do Rio Grande do Sul. Airway resistance (Rint) was measured by the IT, followed by spirometry in all patients. Measurements were repeated after inhalation of salbutamol in order to evaluate bronchodilator response. There was a strong corelation between inverse Rint and forced expiratory volume in one second (FEV1) (r=0.8, p<0.001) and fair correlations between the inverse Rint and mid expiratory flow (MEF) (r=0.74 p<0.001) and between inverse Rint and body mass index (BMI) (r=0.62 p<0.001). The accuracy of bronchodilator response by the IT was tested through the ROC (reciever operating curve), comparing results with spirometry bronchodilator response. An area of 0.75 under the curve was obtained, for the cutoff point of -28% of Rint, achieving a sensitivity of 66% and a specificity of 82%. The findings suggest that Rint shows good correlation with spirometry parameters, although the IT is not sufficiently acurate to replace spirometry in the evaluation of bronchodilator response.
122

Avaliação do valor prognóstico dos biomarcadores cardíacos perioperatórios em pacientes de moderado a alto risco cardiovascular submetidos à cirurgia não-cardíaca / Analysis of the maximal voluntary breath-holding time as pulmonary function tests in patients with obstructive ventilatory defects and normal controls

Borges, Flávia Kessler January 2011 (has links)
Introdução: O teste de apneia respiratória tem sido testado e demonstrou ser de utilidade clínica. Objetivos: Determinar o tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVO) e em indivíduos normais e correlacionar os tempos de apneia com os testes de função pulmonar. Métodos: Foi realizado um estudo caso-controle incluindo pacientes com DVO (casos) e um grupo controle, composto por voluntários com espirometria normal, recrutados no Hospital de Clínicas de Porto Alegre (HCPA). A espirometria foi realizada com espirômetro computadorizado e o teste de apneia respiratória utilizando-se um sistema eletrônico microprocessado e um pneumotacógrafo ((Hans Rudolph ® – Kansas OH, EUA)– Kansas OH, EUA) como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil e os tempos máximos de apneia voluntária inspiratória e expiratória (TAVIM e TAVEM) foram determinados a partir do sinal adquirido. Resultados: Um total de 35 pacientes com DVO (casos) e 16 controles foram incluídos no estudo. O TAVIM foi significativamente menor nos casos (22,3 ± 11,8 s) do que no grupo controle (31,5 ± 15,7 s) com p = 0,025. O TAVEM também foi significativamente menor nos casos (16,9 ± 6,6 s) do que no grupo controle (22,1 ± 7,9 s) com p = 0,017. Foram encontradas correlações positivas moderadas entre TAVIM e CVF (r = 0,476, p = 0,004) e entre TAVIM e VEF1 (r = 0,383, p = 0,023). Conclusões: As medidas de TAVIM e TAVEM foram significativamente menores nos casos do que nos controles, e o TAVIM teve correlação moderada com a CVF e VEF1. Estes resultados fornecem uma evidência adicional da utilidade clínica do tempo de apneia como teste de função pulmonar. / Introduction: Breath-holding test has been tested in some clinical scenarios and has proved to be of clinical utility. Objectives: To determine the maximum voluntary breath-holding time in patients with obstructive ventilator defects and in normal subjects and to correlate the breathholding times with pulmonary function tests. Methods: We conducted a case-control study including patients with obstructive ventilator defects and a control group consisted of volunteers recruited in the same hospital, with normal spirometry. Spirometry was performed using a computerized spirometer. The Breath-holding test was conducted using an electronic microprocessor and a (Hans Rudolph ® – Kansas OH, EUA)pneumotachograph and flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal voluntary apnea inspiratory and expiratory times (MVAIT and MVAET) were determined from the acquired signal. Results: A total of 35 patients with obstructive ventilatory defects and 16 controls met the inclusion criteria and were included in the analysis. The MVAIT was lower in cases (22.3 ± 11.8 seconds) than in controls (31.5 ± 15.7 seconds) (p=0.025). MVAET was also lower in cases than in controls (16.9 ± 6.6 vs. 22.1 ± 7.9; p=0.017). We found positive and significant correlations between MVAIT and FVC (L) (r=0.476; p=0.004) and between MVAIT and FEV1 (L) (r=0.383; p=0.023). Conclusions: MVAIT and MVAET were significant lower in patients with obstructive ventilatory defects than in controls, and that MVAIT was correlated positively with FVC and FEV1 in cases. Our results provide additional evidence of usefulness of MVAIT as a pulmonary function test.
123

Análise dos tempos de apneia voluntária máxima como teste de função pulmonar em pacientes com distúrbios ventilatórios obstrutivos e normais / Analysis of the maximal voluntary breath-holding time as pulmonary function tests in patients with obstructive ventilatory defects and normal controls

Viecili, Raqueli Biscayno January 2011 (has links)
Introdução: O teste de apneia respiratória tem sido testado e demonstrou ser de utilidade clínica. Objetivos: Determinar o tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVO) e em indivíduos normais e correlacionar os tempos de apneia com os testes de função pulmonar. Métodos: Foi realizado um estudo caso-controle incluindo pacientes com DVO (casos) e um grupo controle, composto por voluntários com espirometria normal, recrutados no Hospital de Clínicas de Porto Alegre (HCPA). A espirometria foi realizada com espirômetro computadorizado e o teste de apneia respiratória utilizando-se um sistema eletrônico microprocessado e um pneumotacógrafo ((Hans Rudolph ® – Kansas OH, EUA)– Kansas OH, EUA) como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil e os tempos máximos de apneia voluntária inspiratória e expiratória (TAVIM e TAVEM) foram determinados a partir do sinal adquirido. Resultados: Um total de 35 pacientes com DVO (casos) e 16 controles foram incluídos no estudo. O TAVIM foi significativamente menor nos casos (22,3 ± 11,8 s) do que no grupo controle (31,5 ± 15,7 s) com p = 0,025. O TAVEM também foi significativamente menor nos casos (16,9 ± 6,6 s) do que no grupo controle (22,1 ± 7,9 s) com p = 0,017. Foram encontradas correlações positivas moderadas entre TAVIM e CVF (r = 0,476, p = 0,004) e entre TAVIM e VEF1 (r = 0,383, p = 0,023). Conclusões: As medidas de TAVIM e TAVEM foram significativamente menores nos casos do que nos controles, e o TAVIM teve correlação moderada com a CVF e VEF1. Estes resultados fornecem uma evidência adicional da utilidade clínica do tempo de apneia como teste de função pulmonar. / Introduction: Breath-holding test has been tested in some clinical scenarios and has proved to be of clinical utility. Objectives: To determine the maximum voluntary breath-holding time in patients with obstructive ventilator defects and in normal subjects and to correlate the breathholding times with pulmonary function tests. Methods: We conducted a case-control study including patients with obstructive ventilator defects and a control group consisted of volunteers recruited in the same hospital, with normal spirometry. Spirometry was performed using a computerized spirometer. The Breath-holding test was conducted using an electronic microprocessor and a (Hans Rudolph ® – Kansas OH, EUA)pneumotachograph and flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal voluntary apnea inspiratory and expiratory times (MVAIT and MVAET) were determined from the acquired signal. Results: A total of 35 patients with obstructive ventilatory defects and 16 controls met the inclusion criteria and were included in the analysis. The MVAIT was lower in cases (22.3 ± 11.8 seconds) than in controls (31.5 ± 15.7 seconds) (p=0.025). MVAET was also lower in cases than in controls (16.9 ± 6.6 vs. 22.1 ± 7.9; p=0.017). We found positive and significant correlations between MVAIT and FVC (L) (r=0.476; p=0.004) and between MVAIT and FEV1 (L) (r=0.383; p=0.023). Conclusions: MVAIT and MVAET were significant lower in patients with obstructive ventilatory defects than in controls, and that MVAIT was correlated positively with FVC and FEV1 in cases. Our results provide additional evidence of usefulness of MVAIT as a pulmonary function test.
124

Capacidade de difusão pulmonar e alterações nos exames de complemento C3 e C4 em tabagistas com e sem esquizofrenia

Sperb, Carolina Mello January 2012 (has links)
INTRODUÇÃO: Indivíduos com SZ (esquizofrenia) fumam até três vezes mais que a taxa da população em geral. Constatou-se que fumantes com esquizofrenia fumam mais intensamente do que comparados com fumantes não esquizofrênicos. Adicionalmente, existem relatos não sistemáticos de que apesar de alta taxa de tabagismo, os esquizofrênicos apresentam proporcionalmente pouca lesão pulmonar comparado com tabagistas de igual consumo sem esquizofrenia. Esta diferença, se confirmada, poderia sugerir mecanismos diferentes de reação a agentes exógenos nos sistema respiratório, e entre estes mecanismos diferentes poderia estar o sistema de complemento, já evidenciado em estudos do grupo de pesquisa, porém sem controle para tabagismo. Este estudo investigou se a capacidade de difusão pulmonar em SZ é maior que em NSZ, e se o sistema complemento C3 e C4 é diferente entre SZ e NSZ e ao mesmo tempo está associado a difusão pulmonar de forma diferente em SZ e NSZ. OBJETIVOS: comparar a capacidade de difusão pulmonar e complemento C3 e C4 em pacientes fumantes com e sem esquizofrenia e analisar se existe evidência de mecanismos diferentes mediando prejuízo na capacidade de difusão em tabagistas com e sem SZ. MÉTODOS: esse é um estudo caso controle pareado, desenhado para ser multicêntrico, no momento descrevendo resultados de um centro. Recrutados 30 tabagistas sendo 15 SZ e 15 NSZ pareados por sexo, idade e tempo de tabagismo. Foram medidos complemento C3 e C4, espirometria e difusão pulmonar, dependência de nicotina pelo Teste de Fargerstrom e psicopatologia psiquiátrica nos portadores de esquizofrenia pelo Escala Breve de Avaliação Psiquiátrica (BPRS). Os pacientes foram oriundos do centro colaborador do estudo no HCPA. RESULTADOS: C3 foi significantemente maior em SZ quando comparado com controles (p=0,041), e C4 não mostrou diferença. Houve associação negativa entre o C4 e a capacidade de difusão somente no grupo controle (r=-0,692; p=0,009), sem diferença significativa no grupo de esquizofrênicos (r=0,451; p=0,141). Os grupos foram equivalentes em idade, grau de dependência de nicotina, porém foram diferentes em relação a ocupação (p=0,001). O grupo de esquizofrênicos apresenta maior proporção de desempregados e em benefício do que os controles. Desta forma, apesar de C3 mais aumentado em esquizofrênicos, este sistema aparentemente não media perda de difusão pulmonar, enquanto que aparentemente C4 mostra diferença quanto a prejuízo de difusão em esquizofrênicos tabagistas (maior C4 associado a menor capacidade de difusão somente nos tabagistas sem esquizofrenia). CONCLUSÃO: Quanto ao sistema complemento, houve maior ativação do C3 em tabagistas portadores de esquizofrenia comparados com tabagistas sem esquizofrenia, o que corrobora pesquisas anteriores que descrevem ativação do sistema complemento na SZ indicado pelo aumento dos níveis de C3. Curiosamente, somente nos controles tabagistas foi identificada associação entre aumento de C4 e redução da capacidade de difusão pulmonar. Nos pacientes com esquizofrenia não houve relação entre ativação de C4 e prejuÍzo de difusão pulmonar, o que sugere um padrão de ativação do sistema de complemento diferente dos sujeitos normais, preferencialmente pela via C3 e não pela via C4. Este fator não parece estar afetado pela diferença em escolaridade e trabalho, visto que era esperado que o aumento fosse maior nos esquizofrênicos devido a maior gravidade representada por menor índice de trabalho e menor escolaridade. Este estudo, se confirmado em amostras maiores envolvendo os outros centros colaboradores, pode confirmar existência de mecanismos diferentes de reação inflamatória em esquizofrenia. / Background: Subjects with SZ (schizophrenia) smoke up to three times the rate of the general population. It was found that smokers with schizophrenia smoke more intensely than smokers compared with non-psychiatric. Additionally, there are no systematic reports that despite high rates of smoking, people with schizophrenia have proportionately less lung injury compared with smokers without schizophrenia equal consumption. This difference, if confirmed, would suggest different mechanisms of response to exogenous agents in the respiratory system, and between these different mechanisms could be the complement system, as evidenced in studies of the research group, but not control for smoking. This study investigated whether the pulmonary diffusion capacity in SZ is higher than in non-SZ, and the complement C3 and C4 is different between SZ and NSZ and if at the same time is associated with pulmonary diffusion differently in SZ and NSZ. OBJECTIVES: To compare the pulmonary diffusion capacity and complement C3 and C4 in smokers with and without schizophrenia and examine whether there is evidence of different mechanisms mediating impaired diffusion capacity in smokers with and without SZ. METHODS: This is a matched case-control study, designed as a multicenter, when describing the results of a center. Recruited 30 smokers and 15 non-schizophrenics and 15 schizophrenics matched for sex, age and duration of smoking. We measured C3 and C4 complement, spirometry and DLCO, nicotine dependence and the test Fargerstrom psychiatric psychopathology in patients with schizophrenia by Brief Psychiatric Rating Scale (BPRS). The patients came from the study's collaborating center at HCPA. RESULTS: C3 was significantly higher in SZ compared to controls (p = 0.041), and C4 showed no difference. There was a negative association between C4 and the ability to broadcast only in the control group (r =- 0.692, p = 0.009), no significant difference in the schizophrenic group (r = 0.451, p = 0.141). The groups were equivalent in age, degree of nicotine dependence, but were different in relation to occupation (p = 0.001). The schizophrenic group has a higher proportion of unemployed and for the benefit of the controls. Thus, although most of C3 increased in schizophrenics, this system apparently did not measure loss of pulmonary diffusion, while C4 shows apparent difference in the loss of diffusion in schizophrenic smokers (greater C4 associated with a lower diffusion capacity in smokers without schizophrenia only) . CONCLUSION: As the complement system, activation of C3 was higher in smokers with schizophrenia compared with smokers without schizophrenia, which corroborates previous studies that describe activation of the complement system in SZ indicated by increased levels of C3. Interestingly, only smokers in controls been identified association between increased C4 and reduction of pulmonary diffusion capacity. In patients with schizophrenia there was no relationship between activation of C4 and prejuízo pulmonary diffusion, which suggests a pattern of activation of the complement system different from normal subjects, preferably through C3 and not via C4. This factor does not seem to be affected by the difference in schooling and work, as it was expected that the increase was greater in schizophrenics because of greater severity represented by lower rates of work and less schooling. This study, if confirmed in larger samples involving other collaborating centers, can confirm the existence of different mechanisms of inflammatory response in schizophrenia.
125

Biomechanické charakteristiky nestacionárních respiračních režimů jako možných identifikátorů únavy při monotónní hypokinetické zátěži / Biomechanical chracteristics of nonstationary respiration as possible identificator of tiredeness under hypokinetic loading

Lopotová, Martina January 2014 (has links)
The general topic of this work is to reveal the potential relationship between tiredness cause by hypokinetic monotonous loading and breathing. The aim was to determine if there are suitable respiratory parameters that would indicate this tirednes and, if so, then verify their validity for predicting the tiredness phenomena accompanying huge range of everyday human activities. The performed experiment was attended by five volunteers who absolved measurements of electrical activity of brain, of breathing and of chest volume changes. The course of the experiment and the behaviour of probands were recorded by a camera. In the first part of each maesuremnt, a specified monotonous task (Task Tracking) was performed. The probands have had to follow the target moving with pseudocasual direction and speed by the cursor on the monitor. This task currently reflected the level of reliability and quality of the performed aktivity. In the second part of measurement, the probands had just to relax and watch a movie. Both parts were measured in two conditions - alert and tired (after 24 hours of sleep deprivation) proband. The data were compared with each other and evaluated. The measurements and the results showed that the rate of the tiredness can be fairly reliably assessed by monitoring of the volume...
126

Avaliação da resistência das vias aéreas através da técnica do interruptor em pacientes com fibrose cística

Rocha, Alessandra January 2010 (has links)
Estudos para a avaliação da resistência das vias aéreas de pré-escolares com fibrose cística através da técnica do interruptor (Rint) são escassos. Foi realizado um estudo tranversal, com 38 pacientes acompanhados no ambulatório de Fibrose Cística do Hospital São Lucas da Pontifícia Universidade Católica do Rio Grande do Sul. Foram realizadas medida da Rint, seguida da avaliação espirométrica em todos os pacientes, repetindo os testes após o uso de salbutamol para a aferição da resposta ao broncodilatador. Nos resultados, foram encontradas forte correlação entre o inverso da Rint e o volume expiratório forçado no 1º segundo (VEF1), (r=0,8 p<0,001) e moderadas correlações entre o inverso da Rint e o fluxo expiratório forçado entre 25% e 75% da capacidade vital (FEF 25-75), (r=0,74 p<0,001) e entre o inverso da Rint e o índice de massa corporal (IMC), (r=0,62 p<0,001). A acurácia da avaliação da resposta ao broncodilatador pela Rint, foi testada através da curva ROC (Receiver Operator Characteristic Curve),comparando-se com resposta ao broncodilatador na espirometria. Foi obtida uma área de 0,75 para o ponto de corte de -28%, correspondendo a uma sensibilidade de 66% e uma especificidade de 82%. Os achados indicam que a Rint apresenta boa correlação com a espirometria, no entanto a técnica não possui uma acurácia suficiente para substituir a Espirometria na avaliação da resposta ao broncodilatador. / Few studies have been published on airway resistance measurements using the interrupter technique (IT). We performed a cross-sectional study, evaluating 38 children and adolescents with Cystic Fibrosis (CF), followed at the outpatient CF clinic of Hospital São Lucas from Pontifícia Universidade Católica do Rio Grande do Sul. Airway resistance (Rint) was measured by the IT, followed by spirometry in all patients. Measurements were repeated after inhalation of salbutamol in order to evaluate bronchodilator response. There was a strong corelation between inverse Rint and forced expiratory volume in one second (FEV1) (r=0.8, p<0.001) and fair correlations between the inverse Rint and mid expiratory flow (MEF) (r=0.74 p<0.001) and between inverse Rint and body mass index (BMI) (r=0.62 p<0.001). The accuracy of bronchodilator response by the IT was tested through the ROC (reciever operating curve), comparing results with spirometry bronchodilator response. An area of 0.75 under the curve was obtained, for the cutoff point of -28% of Rint, achieving a sensitivity of 66% and a specificity of 82%. The findings suggest that Rint shows good correlation with spirometry parameters, although the IT is not sufficiently acurate to replace spirometry in the evaluation of bronchodilator response.
127

Fisioterapia respiratória em cirurgia bariátrica: procediemntos de avaliação e intervenção

Moulim, Marcela Cangussu Barbalho 16 May 2011 (has links)
Made available in DSpace on 2016-06-02T20:18:14Z (GMT). No. of bitstreams: 1 3818.pdf: 2689353 bytes, checksum: 843410f25e482425b98ea3159b6b4b1e (MD5) Previous issue date: 2011-05-16 / Universidade Federal de Sao Carlos / Obesity, considered a worldwide epidemic, causes serious damage to health, especially to the respiratory function. These changes are caused by the extra adipose tissue in the chest wall and abdominal cavity of obese patients, which impairs the movement of the diaphragm and compress the lungs. In view of the limitations of conservative treatments, surgical interventions have been recommended as treatment of choice. This procedure can be carried out by laparoscopy or laparotomy (open). Because the pulmonary function is already in a compromised state before the operation in obese individuals, the choice for the surgical procedure to be used should consider the impact on respiration, thereby reducing the risk of developing postoperative pulmonary complications. Thus, the goal of the first study was to compare the effect on lung function and on pain of bariatric surgery performed by laparoscopy and laparotomy. Participated in this study 26 obese women who underwent bariatric surgery by laparoscopy (LG, n = 13) or laparotomy (OG, n = 13). The respiratory evaluation was performed in the preoperative period and on the second postoperative day by spirometry and other tests that evaluated respiratory muscle strength and diaphragmatic mobility. Pain was assessed by visual analogue scale on the second postoperative day. The results indicate that although there was no difference in the incidence of pulmonary complications and hospital stay between the groups, bariatric surgery performed by laparoscopy caused less pain and less impairment of pulmonary function in the postoperative period. Knowing the degree of impairment of pulmonary function in the postoperative period of bariatric surgery, especially by lapartomy, some strategies have been studied in order to attenuate these changes, such as preoperative inspiratory muscle training (IMT). Therefore, the objective of the second study was to determine whether the preoperative IMT in open bariatric surgery, is able to mitigate the impact of surgical trauma on muscle strength, in lung volumes and diaphragmatic mobility. We evaluated 32 obese women who underwent open bariatric surgery and randomized into two groups: one group that underwent preoperative IMT (IMT group - n = 15) or who received only conventional treatment (control group - n = 17). Tests were conducted to evaluate the respiratory muscle strength, lung volume and diaphragmatic excursion before the training period, after the training period and the first postoperative day. According to the results, could be verified that preoperative IMT improves inspiratory muscle strength (MIP) and attenuates the negative impact of open bariatric surgery to this variable, although it seems not to influence the MEP, the lung volume and diaphragmatic excursion. Additionally, studies have suggested that weight loss can reverse many changes in lung function caused by obesity. Therefore, in the third and final study, we evaluated the lung function of some patients (n = 14) of first and second study, sedentary, 1 year after bariatric surgery by means of spirometry and respiratory muscle strength tests. From the results we found that weight loss induced by bariatric surgery provides an improvement in ventilatory mechanics, increased lung volumes and respiratory endurance (MVV). However, there was also a reduction in respiratory muscle strength, probably caused by loss of lean body mass and reducing the burden breathing after weight loss. / A obesidade, considerada uma epidemia mundial atualmente, causa sérios danos à saúde em geral e especialmente à função respiratória. Essas alterações são causadas pelo grande depósito de gordura na região do tórax e abdômen dos obesos, que prejudica a movimentação do músculo diafragma, levando à redução do espaço intratorácico ocupado pelos pulmões. Nos casos de obesidade mórbida, a cirurgia tem sido recomendada como tratamento de escolha, já que o tratamento conservador é, na maioria das vezes, falho. Tal procedimento pode ser realizado por videolaparoscopia ou por laparotomia. Por se tratar de indivíduos que já apresentam prejuízos à função pulmonar no período pré-operatório, a escolha da via de acesso cirúrgico em obesos deve também levar em consideração aquela técnica que tenha menor repercussão na função pulmonar, reduzindo assim o risco de aparecimento de complicações pulmonares no período pós-operatório. Sendo assim, o objetivo do primeiro estudo foi comparar a repercussão na função pulmonar e na dor da cirurgia bariátrica realizada por videolaparoscopia e por laparotomia. Participaram desse estudo 26 mulheres obesas, que realizaram a cirurgia bariátrica por videolaparoscopia (GV, n=13) ou laparotomia (GL, n=13). A avaliação respiratória foi realizada no período pré-operatório e no segundo dia de pós-operatório por meio da espirometria, da manovacuometria e da mobilidade diafragmática. A dor foi avaliada pela escala visual analógica no segundo dia de pós-operatório. Os resultados obtidos indicam que apesar de não ter havido diferença na incidência de complicações pulmonares e no tempo de internação hospitalar entre os grupos, a cirurgia bariátrica realizada por videolaparoscopia causou menos dor e menor prejuízo à função pulmonar no período pós-operatório. Sabendo do grau de comprometimento da função pulmonar no período pós-operatório de cirurgia bariátrica, especialmente por laparotomia, algumas estratégias têm sido estudadas com o objetivo de atenuar essas alterações, tais como o treinamento muscular inspiratório (TMI) no pré-operatório. Sendo assim, o objetivo do segundo estudo foi verificar se a fisioterapia respiratória, por meio do TMI, realizada no préoperatório de cirurgia bariátrica aberta, é capaz de atenuar o impacto do trauma cirúrgico na força muscular respiratória, nos volumes pulmonares e na mobilidade diafragmática. Foram avaliadas 32 mulheres obesas submetidas à cirurgia bariátrica aberta e randomizadas em dois grupos: um grupo que realizou TMI no pré-operatório (grupo TMI - n=15) e outro que recebeu apenas o tratamento convencional (grupo controle n=17). Foram realizados testes para avaliação da força muscular respiratória, dos volumes pulmonares e da mobilidade diafragmática antes do período de treinamento, após o período de treinamento e no primeiro dia de pós-operatório. De acordo com os resultados pôde-se verificar que o TMI pré-operatório aumenta a força muscular inspiratória (PImax) e atenua o impacto negativo da cirurgia bariátrica aberta para essa variável, apesar de parecer não influenciar a PEmax, os volumes pulmonares e a mobilidade diafragmática. Adicionalmente, estudos têm sugerido que a perda de peso pode reverter muitas alterações da função pulmonar causadas pela obesidade. Por isso, no terceiro e último estudo, foi avaliada a função pulmonar de parte das voluntárias (n=14) do primeiro e segundo estudo, sedentárias, após 1 ano da realização da cirurgia bariátrica, por meio dos testes de espirometria e manovacuometria. A partir dos resultados observamos que a perda de peso induzida pela cirurgia bariátrica promove uma melhora na mecânica ventilatória, aumento dos volumes pulmonares e da endurance respiratória (VVM). No entanto, houve também uma redução na força dos músculos respiratórios, provavelmente causada pela perda de massa magra e redução da sobrecarga respiratória após a perda de peso.
128

Avaliação do valor prognóstico dos biomarcadores cardíacos perioperatórios em pacientes de moderado a alto risco cardiovascular submetidos à cirurgia não-cardíaca / Analysis of the maximal voluntary breath-holding time as pulmonary function tests in patients with obstructive ventilatory defects and normal controls

Borges, Flávia Kessler January 2011 (has links)
Introdução: O teste de apneia respiratória tem sido testado e demonstrou ser de utilidade clínica. Objetivos: Determinar o tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVO) e em indivíduos normais e correlacionar os tempos de apneia com os testes de função pulmonar. Métodos: Foi realizado um estudo caso-controle incluindo pacientes com DVO (casos) e um grupo controle, composto por voluntários com espirometria normal, recrutados no Hospital de Clínicas de Porto Alegre (HCPA). A espirometria foi realizada com espirômetro computadorizado e o teste de apneia respiratória utilizando-se um sistema eletrônico microprocessado e um pneumotacógrafo ((Hans Rudolph ® – Kansas OH, EUA)– Kansas OH, EUA) como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil e os tempos máximos de apneia voluntária inspiratória e expiratória (TAVIM e TAVEM) foram determinados a partir do sinal adquirido. Resultados: Um total de 35 pacientes com DVO (casos) e 16 controles foram incluídos no estudo. O TAVIM foi significativamente menor nos casos (22,3 ± 11,8 s) do que no grupo controle (31,5 ± 15,7 s) com p = 0,025. O TAVEM também foi significativamente menor nos casos (16,9 ± 6,6 s) do que no grupo controle (22,1 ± 7,9 s) com p = 0,017. Foram encontradas correlações positivas moderadas entre TAVIM e CVF (r = 0,476, p = 0,004) e entre TAVIM e VEF1 (r = 0,383, p = 0,023). Conclusões: As medidas de TAVIM e TAVEM foram significativamente menores nos casos do que nos controles, e o TAVIM teve correlação moderada com a CVF e VEF1. Estes resultados fornecem uma evidência adicional da utilidade clínica do tempo de apneia como teste de função pulmonar. / Introduction: Breath-holding test has been tested in some clinical scenarios and has proved to be of clinical utility. Objectives: To determine the maximum voluntary breath-holding time in patients with obstructive ventilator defects and in normal subjects and to correlate the breathholding times with pulmonary function tests. Methods: We conducted a case-control study including patients with obstructive ventilator defects and a control group consisted of volunteers recruited in the same hospital, with normal spirometry. Spirometry was performed using a computerized spirometer. The Breath-holding test was conducted using an electronic microprocessor and a (Hans Rudolph ® – Kansas OH, EUA)pneumotachograph and flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal voluntary apnea inspiratory and expiratory times (MVAIT and MVAET) were determined from the acquired signal. Results: A total of 35 patients with obstructive ventilatory defects and 16 controls met the inclusion criteria and were included in the analysis. The MVAIT was lower in cases (22.3 ± 11.8 seconds) than in controls (31.5 ± 15.7 seconds) (p=0.025). MVAET was also lower in cases than in controls (16.9 ± 6.6 vs. 22.1 ± 7.9; p=0.017). We found positive and significant correlations between MVAIT and FVC (L) (r=0.476; p=0.004) and between MVAIT and FEV1 (L) (r=0.383; p=0.023). Conclusions: MVAIT and MVAET were significant lower in patients with obstructive ventilatory defects than in controls, and that MVAIT was correlated positively with FVC and FEV1 in cases. Our results provide additional evidence of usefulness of MVAIT as a pulmonary function test.
129

Análise dos tempos de apneia voluntária máxima como teste de função pulmonar em pacientes com distúrbios ventilatórios obstrutivos e normais / Analysis of the maximal voluntary breath-holding time as pulmonary function tests in patients with obstructive ventilatory defects and normal controls

Viecili, Raqueli Biscayno January 2011 (has links)
Introdução: O teste de apneia respiratória tem sido testado e demonstrou ser de utilidade clínica. Objetivos: Determinar o tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVO) e em indivíduos normais e correlacionar os tempos de apneia com os testes de função pulmonar. Métodos: Foi realizado um estudo caso-controle incluindo pacientes com DVO (casos) e um grupo controle, composto por voluntários com espirometria normal, recrutados no Hospital de Clínicas de Porto Alegre (HCPA). A espirometria foi realizada com espirômetro computadorizado e o teste de apneia respiratória utilizando-se um sistema eletrônico microprocessado e um pneumotacógrafo ((Hans Rudolph ® – Kansas OH, EUA)– Kansas OH, EUA) como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil e os tempos máximos de apneia voluntária inspiratória e expiratória (TAVIM e TAVEM) foram determinados a partir do sinal adquirido. Resultados: Um total de 35 pacientes com DVO (casos) e 16 controles foram incluídos no estudo. O TAVIM foi significativamente menor nos casos (22,3 ± 11,8 s) do que no grupo controle (31,5 ± 15,7 s) com p = 0,025. O TAVEM também foi significativamente menor nos casos (16,9 ± 6,6 s) do que no grupo controle (22,1 ± 7,9 s) com p = 0,017. Foram encontradas correlações positivas moderadas entre TAVIM e CVF (r = 0,476, p = 0,004) e entre TAVIM e VEF1 (r = 0,383, p = 0,023). Conclusões: As medidas de TAVIM e TAVEM foram significativamente menores nos casos do que nos controles, e o TAVIM teve correlação moderada com a CVF e VEF1. Estes resultados fornecem uma evidência adicional da utilidade clínica do tempo de apneia como teste de função pulmonar. / Introduction: Breath-holding test has been tested in some clinical scenarios and has proved to be of clinical utility. Objectives: To determine the maximum voluntary breath-holding time in patients with obstructive ventilator defects and in normal subjects and to correlate the breathholding times with pulmonary function tests. Methods: We conducted a case-control study including patients with obstructive ventilator defects and a control group consisted of volunteers recruited in the same hospital, with normal spirometry. Spirometry was performed using a computerized spirometer. The Breath-holding test was conducted using an electronic microprocessor and a (Hans Rudolph ® – Kansas OH, EUA)pneumotachograph and flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal voluntary apnea inspiratory and expiratory times (MVAIT and MVAET) were determined from the acquired signal. Results: A total of 35 patients with obstructive ventilatory defects and 16 controls met the inclusion criteria and were included in the analysis. The MVAIT was lower in cases (22.3 ± 11.8 seconds) than in controls (31.5 ± 15.7 seconds) (p=0.025). MVAET was also lower in cases than in controls (16.9 ± 6.6 vs. 22.1 ± 7.9; p=0.017). We found positive and significant correlations between MVAIT and FVC (L) (r=0.476; p=0.004) and between MVAIT and FEV1 (L) (r=0.383; p=0.023). Conclusions: MVAIT and MVAET were significant lower in patients with obstructive ventilatory defects than in controls, and that MVAIT was correlated positively with FVC and FEV1 in cases. Our results provide additional evidence of usefulness of MVAIT as a pulmonary function test.
130

Complicações pós-operatórias em cirurgia torácica relacionadas aos índices e testes preditores de risco cirúrgico pré-operatórios /

Ambrozin, Alexandre Ricardo Pepe. January 2009 (has links)
Resumo: Algumas variáveis propostas para predizer o risco de complicação pósoperatória (CPO) são a altura no teste da escada (TE) e a distância do teste de caminhada de seis minutos (TC6) e acreditamos que o tempo no teste da escada (tTE) também pode ser utilizado para este fim. Além disso, são utilizados a prova de função pulmonar e os índices pré-operatórios. Objetivo: Determinar se os índices de Torrington e Henderson, American Society of Anesthesiologists, Goldman, Detsky e Charlson, a variável VEF1 da espirometria e as variáveis obtidas nos testes de esforço (TC6 e TE) podem ser preditivos das complicações pós-toracotomia e qual deles seria o melhor preditor dessas complicações. Método: Foram avaliados pacientes com indicação de toracotomia para ressecção pulmonar ou não, maiores de 18 anos. As comorbidades foram obtidas e traçados os índices de Comorbidade de Charlson, de risco de Torrington e Henderson, de Goldman, de Detsky e o ASA. A espirometria foi realizada de acordo com a ATS, em espirômetro Medgraphics Pulmonary Function System 1070. O TC6 foi realizado segundo os critérios da ATS e a distância prevista calculada. O TE foi realizado numa escada à sombra, composta por seis lances, num total de 12,16m de altura. O tTE em segundos percorrido na subida da altura total foi obtido e a partir deste a Potência (P) foi calculada utilizando a fórmula clássica. Também foi estimado o VO2 a partir do tTE (VO2 t) e da P (VO2 P). No intra-operatório foram registradas as complicações e o tempo cirúrgico. E no pós-operatório foram registradas as CPOs. Para análise estatística os pacientes foram divididos em grupos sem e com CPO. Foi aplicado o teste de acurácia para obtenção dos valores preditivos para o TC6 e para o tTE, a curva ROC e dessa o ponto de corte. As variáveis foram testadas para uma possível associação com as CPO pelo teste t de ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Some varieties purposed to predict the postoperative complication (POC) risk are the height in the stair-climbing test (SCT) and the distance in the six minute walk test (6MWT), we also believe that the time on the stair-climbing test can also be used for this purpose. Besides, the pulmonary function test and the preoperative index are also used. Objectives: We aim to determine if the Charlson, Torrington and Henderson, Goldman, Detsky and American Society of Anesthesiologists indexes, the variable FEV1 obtained on the Spirometry and on the Cardiopulmonary Exercise Testing (6MWT, SCT) can be predictive of the complication after thoracic surgery and which one of them would be the best. Method: Patients with indication to thoracic surgery, for resection or not, and older than 18 years old were evaluated. The comorbidities were obtained and the Comorbidity Charlson, Torrington and Henderson risk, Goldman, the Detsky and ASA indexes were calculated. The spirometry was performed according to ATS in Medgraphics Pulmonary Function System 1070. The 6MWT was performed according to the ATS criteria and the predicted distance was calculated. The SCT was performed indoor, on six flights of stairs, which results as a 12,16m climb. The time on the SCT was obtained after finished the stair height total in seconds and the Power (P) was calculated using the class formula. The maximum oxygen uptake (VO2) was estimated from the time of SCT (VO2 t) and the P (VO2 P). In the intraoperative was registered the complication and the surgery time. And in the postoperative was registered the POC. In the statistics analysis, the patients were divided in groups with and without POC. It was applied the accuracy test for the distance 6MWT and for the time in the SCT. We have found the cutoff from the ROC curve. The correlation between the variables and POC were tested using the t test for independent population ... (Complete abstract click electronic access below) / Orientador: Daniele Cristina Cataneo / Coorientador: Antônio José Maria Cataneo / Banca: Roberto Saab Junior / Banca: Paulo Monoel Pego Fernandes / Banca: Irma de Godoy / Banca: Lidia Raquel de Carvalho / Doutor

Page generated in 0.1262 seconds