• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 137
  • 26
  • 22
  • 9
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 219
  • 129
  • 58
  • 56
  • 53
  • 47
  • 38
  • 37
  • 36
  • 32
  • 30
  • 29
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

PIC Microcontroller Based Smart Inhaler System for Asthma Patients

Balasubramanian, Radhika 08 October 2012 (has links)
No description available.
152

Impulsna oscilometrija u evaluaciji astme i hronične opstruktivne bolesti pluća / Evaluation of Asthma and Chronic Obstructive Pulmonary Disease by Impulse Oscillometry

Vukoja Marija 29 October 2014 (has links)
<p>Astma i hronična opstruktivna bolest pluća (HOBP) su najče&scaron;će hronične nezarazne bolesti respiratornog sistema i predstavljaju značajan zdravstveni problem. U dijagnostici i proceni stepena poremećaja disajne funkcije u ovih bolesnika najče&scaron;će se koriste spirometrija i telesna pletizmografija. Impulsna oscilometrija predstavlja novu metodu u dijagnostici poremećaja plućne funkcije. Ova metoda je jednostavna za izvođenje i minimalno zavisi od saradnje pacijenta.Osnovni cilj ove doktorske disertacije bio je da se uporede parametri dobijeni impulsnom oscilometrijom, spirometrijom i telesnom pletizmografijom kod pacijenata sa astmom i hroničnom opstruktivnom bolesti pluća, utvrdi senzitivnost navednih metoda u detekciji opstruktivnog poremećaja ventilacije kao i povezanost parametara impulsne oscilometrije, spirometrije i telesne pletizmografije i stepena težine dispnoičnih tegoba kod odraslih pacijenata sa astmom i HOBP. Korelacijom parametara dobijenih impulsnom oscilometrijom i spirometrijom dobijena je umerena negativna korelacija vrednosti R5 sa FEV1 kod pacijenata sa astmom (r= -0.47, r&lt;0.001) i HOBP (r= -0.50, r&lt;0.001), kao i umerena pozitivna korelacija X5 sa FEV1 (r= 0.54, r&lt;0.001, kod pacijenata sa astmom; r= 0.56, r&lt;0.001 kod pacijenata sa HOBP). Registrovana je dobra korelacija Rt sa vrednostima R5 (r=0.63, r&lt;0.001) i H5 (r= -0.55, r&lt;0.001) kod pacijenata sa astmom, kao dobra korelacija Rt sa R5 (r=0.73, r&lt;0.001) i H5 (r= -0.74, r&lt;0.001) kod pacijenata sa HOBP. Kod pacijenata sa astmom nije registrovana razlika između tri metode u detekciji opstruktivnog poremećaja ventilacije kod pacijenata sa simptomima bolesti, dok se upotrebom sve tri metode povećala se senzitivnost. Sve tri metode bile su u slaboj korelaciji sa stepenom dispnoičnih tegoba kod pacijenta sa astmom. Svi HOBP pacijenti imali su spirometrijski registrovanu opstrukciju disajnih puteva. Senzitivnost impusne oscilometrije raste sa stepenom opstrukcije disajnih puteva, te je sposobnost detekcije opstruktivnog poremećaja ventilacije kod pacijenata sa FEV1%&lt;80 % iznosila 55%, 95% CI 43-67 %, a kod pacijenata sa FEV1%&lt;70 % 61%, 95% CI 47-73%. Registrovana je statistički značajna razlika vrednosti oscilometrijskih parametara u odnosu na spirometrijski stadijum HOBP. Kod pacijenata sa HOBP, sve tri metode bile su u umerenoj korelaciji sa stepenom dispnoičnih tegoba. Zaključujemo da postoji umerena korelacija impulsne oscilometrije sa spirometrijom i telesnom pletizmografijom kod pacijenta sa astmom i HOBP. Impulsna oscilometrija bolje korelira sa telesnom pletizmografijom u poređenju sa spirometrijom. Korelacija tri metode raste sa stepenom opstrukcije disajnih puteva. Komplementarna upotreba tri metode daje sveobuhvatniju sliku respiratorne funkcije kod pacijenata sa astmom i HOBP.</p> / <p>Asthma and chronic obstructive pulmonary disease (COPD) are most common chronic noninfectious diseases of the respiratory system, representing a major health issue. Spirometry and body plethysmography are the procedures which are most often performed to diagnose these diseases and evaluate the lung function impairment of the affected patients. Impulse oscillometry is a novel procedure to establish the lung function impairment. It is easy to perform, and minimally depends on a patient&#39;s cooperation. The major objective of this Ph. D. thesis is to compare the parameters obtained by impulse oscillometry, spirometry and body plethysmography in patients with asthma and COPD, establish the sensitivity of these procedures in detecting an obstructive ventilation disorder, and correlate the parameters of impulse oscillometry, spirometry and body plethysmpography to the severity of dyspneic symptoms in adult asthma and COPD patients. Correlating the parameters obtained by impulse oscillometry and spirometry, a moderate negative correlation of R5 values to FEV1 in asthma (r= -0.47, р&lt;0.001) and COPD patients (r= -0.50, р&lt;0.001) has been obtained, as well as a moderate positive correlation of X5 to FEV1 (r= 0.54, р&lt;0.001, in asthmatics; r= 0.56, р&lt;0.001 in COPD patients). A good correlation of Rt to R5 (r=0.63, р&lt;0.001) and Х5 values (r= -0.55, р&lt;0.001) has been registered in asthmatics, as well as a good correlation of Rt to R5 (r=0.73, р&lt;0.001) and Х5 (r= -0.74, р&lt;0.001) in COPD patients. In asthma patients, the three analysed procedures exhibited no difference in detecting an obstructive ventilation disorder in the patients with manifested symptoms, while the sensitivity improved when the procedures were complementary performed. Any of the three procedures correlated poorly to the severity of dyspneic symptoms in asthma patients. All COPD patients had a spirometry-registered airway obstruction. The sensitivity of impulse oscillometry increased with the severity of the airway obstruction, so its capacity to detect an obstructive ventilation disorder in the patients with FEV1%&lt;80 % was 55%, 95% CI 43-67 %, and in the patients with FEV1%&lt;70 %, it amounted to 61%, 95% CI 47-73%. A statistically significant difference in the values of all oscillometry parameters was registered depending on the spirometric COPD stage. In COPD patients, all the three procedures were moderately correlated to the severity of dyspenic symptoms. In conclusion, there is a moderate correlation of impulse oscillometry to spirometry and body plethysmography in asthma and COPD patients. Impulse oscillometry correlates better to body plethysmography than to spirometry. The correlation of the three procedures increases with the severity of the airway obstruction. The complementary application of these three procedures provides a more accurate assessment of the respiratory function in asthma and COPD patients.</p>
153

Stanovení nových referenčních hodnot maximálních inspiračních a expiračních tlaků a hodnot PO.1 u normální populace ve věkovém rozmezí 16 až 17 let / Definition of new referential values of maximum inspiratory and expiratory pressures and P0.1 values in normal population of the 16 - to - 17 age range

Kálalová, Tereza January 2014 (has links)
The purpose of this thesis is to define norms for inspiratory (Pimax) and expiratory (Pemax) pressures and mouth occlusion pressure (P0.1) in healthy white population of the 16-17 age group in the Czech Republic, specifically the capital city of Prague and its close vicinity. Furthermore, this work aspires to ascertain whether there is a correlation between the respiratory pressures, P0.1 and selected anthropometric and pulmonary values. In order to define the norms, 79 children were tested, including 41 boys and 38 girls 16 to 17 years old. After establishing the subjects' case histories, anthropometric, spirometric inspiratory, expiratory and forced vital capacity measurements were made. The study defined the norms of respiratory pressures and P0.1 in 16 to 17-year-old boys and girls, thus achieving its main goal. Furthermore, a difference was found between the average measured Pimax and Pemax values for boys and girls, with the boys showing higher values comparing with the girls. The study did not ascertain a correlation between respiratory pressures, P0.1 and selected anthropometric values (age, height, weight, BMI, BSA). No correlation was found between respiratory pressures and static pulmonary volumes. Powered by TCPDF (www.tcpdf.org)
154

Ověření účinku přípravku Ventolin Inhaler N u sportovců bez diagnózy astmatu. / Verification of the effect of Ventolin Inhaler N in athletes without a diagnosis of asthma.

Hampejsová, Kateřina January 2014 (has links)
Title: Verification of the effect of Ventolin Inhaler N in athletes without a diagnosis of asthma. Thesis' objective: The main objective of this Thesis is to determine whether the medicament Ventolin Inhaler N affects the performance of athletes without a diagnosis of asthma. Specifically, it is about how this medicament influences the parameters in aerobic and anaerobic zone, spirometric parameters and total performance. The other objective is to verify if any of the adverse events of Ventolin Inhaler N appears before the load. Methods: The descriptive analysis method for obtaining information about the issue is used in this Thesis. A test up to a vita maxima on a treadmill according to the protocol of Bunce, spirometric measurement and an answer sheet for the evaluation of subjective feelings immediately after the test is used for the research. Test was realized using a method repeated measurement, each tested person passed the test twice, once using the Ventolin Inhaler N and once without it. Results were recorded into tables and analyzed in SPSS programme using statistical methods. Results: The medicament Ventolin Inhaler N affects the performance of athletes without a diagnosis of asthma. The Ventolin influences the spirometric parameters measured before the test (FEV1, FVC), the spirometric...
155

Avaliação do impacto da realização de espirometria na consulta médica nas condutas clínicas em pacientes com fibrose cística / Evaluation of the impact of the performance of spirometry in the medical consultation in the clinical conducts in patients with cystic fibrosis

Mota, Carolina Silva Barboza de Aquino 24 May 2019 (has links)
Introdução: A doença pulmonar na fibrose cística (FC) é obstrutiva e supurativa, caracterizada por exacerbações recorrentes dos sintomas respiratórios e pela deterioração progressiva da função pulmonar. A gravidade da doença pulmonar é mensurada pelo volume expiratório forçado no primeiro segundo (VEF1), obtido através da espirometria. O VEF1 é um preditor de mortalidade bem documentado na literatura, utilizado como desfecho em ensaios clínicos e como parâmetro para indicar e monitorizar respostas terapêuticas. O objetivo do estudo foi avaliar o impacto da realização da espirometria em todas as consultas médicas na frequência das intervenções clínicas e na função pulmonar dos pacientes com FC. Métodos: Pacientes com diagnóstico de FC em acompanhamento em centro de referência, com idade entre 5-18 anos, realizaram uma espirometria antes de cada consulta médica durante o período de um ano (2014). Os dados coletados durante o seguimento foram comparados com o período de 24 meses anteriores ao estudo, período no qual os pacientes realizavam rotineiramente apenas uma espirometria a cada seis meses. Os principais desfechos avaliados foram diagnóstico de exacerbação pulmonar, frequência de introdução de novas terapias de uso crônico, encaminhamento ao ambulatório de transplante pulmonar e média do VEF1 basal. A utilização da espirometria para tomada de decisão clínica foi referida pelo médico assistente através de questionário. Resultados: Participaram do estudo 80 pacientes (idade média 12,1 anos e 61,3% do sexo masculino), tendo sido realizadas 418 consultas durante o ano de seguimento (5,2 consultas por paciente/ano). Exacerbações pulmonares foram diagnosticadas em 27,5% das consultas, com taxa de 1,44 exacerbações pulmonares por paciente/ano, frequência significativamente maior quando comparada com os anos 2012 (p=0,001) e 2013 (p=0,05). A espirometria foi útil para diagnóstico de exacerbação pulmonar em 83,5% das vezes, e em 21,9% destes casos o diagnóstico de exacerbação foi feito exclusivamente pelo parâmetro do declínio agudo do VEF1. Terapias de uso crônico foram introduzidas 0,4 vezes por paciente/ano, sem diferença estatisticamente significante com os períodos anteriores. A espirometria foi útil em 83,9% das vezes em que se iniciou uma nova terapia. Foram realizados três encaminhamentos para o serviço de transplante pulmonar, sem diferença estatística com os períodos anteriores. A média do VEF1 basal da amostra foi de 80% do previsto (DP+28,2), sem diferença significativa com os valores observados nos anos anteriores 78,1% em 2013 (p=0,27); e 76,7% em 2012 (p=0,7), indicando tendência para manutenção da função pulmonar destes pacientes. Conclusão: O estudo evidencia um impacto significativo da realização da espirometria rotineira em todas as consultas médicas no aumento do reconhecimento e tratamento de exacerbações pulmonares, com potenciais benefícios na função pulmonar destes pacientes / Background: Pulmonary disease in cystic fibrosis (CF) is obstructive and suppurative, characterized by recurrent exacerbations of respiratory symptoms and progressive deterioration of lung function. The severity of lung disease is measured by forced expiratory volume in the first second (FEV1), obtained through spirometry. FEV1 is a well documented predictor of mortality in the literature, used as an endpoint in clinical trials and as a parameter for indicating and monitoring therapeutic responses. The aim of the study was to evaluate the impact of performing spirometry during routine medical visits on the frequency of clinical interventions and lung function in CF patients. Methods: Patients with a diagnosis of CF in follow-up at the reference center, aged 5-18 years, underwent spirometry before each clinical visit during a one-year period (2014). Data collected during follow-up were compared with the 24-month period prior to the study, during which patients routinely performed only one spirometry every six months. The outcomes included diagnosis of pulmonary exacerbation, frequency of introduction of new therapies for chronic use, referral for pulmonary transplantation, mean baseline FEV1. The use of spirometry for clinical decision making was reported by the attending physician by questionnaire. Results: 80 patients (mean age 12.1 years and 61.3% males) participated in the study, and 418 visits were performed during the year of follow-up (5.2 visits per patient/year). Pulmonary exacerbations were diagnosed in 27.5% of the consultations, with a rate of 1.44 pulmonary exacerbations per patient/year, significantly higher than the year of 2012 (p = 0.001) and 2013 (p = 0.05). Spirometry was useful for diagnosis of pulmonary exacerbation in 83.5% of the time, and in 21.9% of these cases the diagnosis of exacerbation was made exclusively by the parameter of the acute decline of FEV1. Chronic use therapies were introduced 0.4 times per patient/year, with no statistically significant difference with previous periods. Spirometry was useful in 83.9% of the times a new therapy was started. Three referrals were made for pulmonary transplantation, with no statistical difference with previous periods. The mean baseline FEV1 of the sample was 80% predicted (SD+28.2), compared to 78.1% in 2013 (p=0.27); and 76.7% in 2012 (p=0.7), indicating a tendency for stabilization of the pulmonary function of these patients. Conclusion: The study evidences a significant impact of routine spirometry during routine encounters of CF patients in the increase of diagnosis and treatment of pulmonary exacerbations, with potential benefits for the pulmonary function of these patients
156

Avaliação da influência da dor pós-operatória na função pulmonar de pacientes submetidos à revascularização do miocárdio com diferentes drenagens torácicas / Evaluation of the influence of postoperative pain on the pulmonary function of patients submitted to myocardial revascularization with different thoracic drainage

Vieira, Irinea Beatriz Carvalho Ozelami 28 March 2018 (has links)
Justificativa e objetivos: Estudo longitudinal, prospectivo, randomizado para avaliar a influência do uso de um ou dois drenos pleuromediastinais na dor pós-operatória, na função pulmonar e na liberação de interleucinas pró-inflamatórias dos pacientes submetidos à revascularização do miocárdio. Casuística e método: 33 pacientes escalados para cirurgia eletiva de revascularização do miocárdio, com uso de CEC, foram alocados por sorteio em dois grupos: grupo GDU (dreno único) e grupo GDD (dreno duplo). No período pósoperatório foram avaliadas a intensidade da dor, a performance ventilatória por meio das medidas da CVF e da VEF1 e foram quantificadas as concentrações de interleucinas nos três primeiros dias do período pós-operatório. Resultados: 33 pacientes analisados, 16 no grupo GDU e 17 no grupo GDD. O grupo GDU apresentou valores espirométricos maiores que o grupo GDD (p<0,001) no pós-operatório, denotando menor interferência do dreno na respiração. A PaO2 arterial, no primeiro e segundo PO, aumentou significantemente no grupo GDU quando comparada com o grupo GDD (p<0,001). A intensidade da dor no grupo GDU, antes e após a espirometria, foi menor que no grupo GDD (p<0,001). Houve aumento significativo dos valores espirométricos em ambos os grupos, após a retirada do dreno pleural. As variações das concentrações de interleucina não foram significativas quando se compararam valores intra e intergrupos, embora tenha havido uma tendência a aumento da IL- 6, no primeiro dia de pós-operatório no grupo GDD. Conclusão: O uso de apenas um dreno torácico altera menos a função pulmonar, possibilita uma melhor recuperação dos parâmetros respiratórios, além de mostrar eficácia semelhante a dois drenos na drenagem torácica. / BACKGROUND AND OBJECTIVES: A prospective, randomized, longitudinal study to evaluate the influence of one or two pleuromediastinal drains on postoperative pain, pulmonary function, and the release of proinflammatory interleukins from patients undergoing myocardial revascularization. Patients and methods: 33 patients who underwent elective coronary artery bypass grafting (CABG) were randomized into two groups: GDU group (single drain) and GDD group (double drain). In the postoperative period, pain intensity, ventilatory performance were measured through FVC and FEV1 measurements, and interleukin concentrations were quantified in the first three days of the postoperative period. Results: 33 patients were analyzed, 16 in the GDU group and 17 in the GDD group. The GDU group presented higher spirometric values than the GDD group (p <0.001) in the postoperative period, indicating less interference of the drain in the breath. The arterial PaO2, in the first and second PO, increased significantly in the GDU group when compared to the GDD group (p <0.001). The pain intensity in the GDU group, before and after spirometry, was lower than in the GDD group (p <0.001). There was a significant increase in spirometric values in both groups, after the pleural drainage was removed. Variations in interleukin concentrations were not significant when comparing intra and intergroup values, although there was a tendency for IL-6 to increase on the first postoperative day in the GDD group. Conclusion: The use of only one thoracic drainage modifies pulmonary function less, allows better recovery of respiratory parameters, and shows similar efficacy to two drains in the thoracic drainage.
157

Fonction ventilatoire, asthme et facteurs de risque cardiométabolique / Lung function, asthma, and cardiometabolic risk factors

Leone, Nathalie 19 February 2014 (has links)
Introduction Les mécanismes sous-jacents à la relation entre la fonction ventilatoire et l’incidence de pathologies cardiovasculaires restent incertains. Le syndrome métabolique, cluster des principaux facteurs de risque cardiovasculaire dont l’obésité abdominale, pourrait jouer un rôle dans cette relation. Le lien entre le syndrome métabolique et la fonction ventilatoire est méconnu. Parallèlement, peu de données ont été publiées sur la relation entre l’obésité abdominale et le risque d’asthme. De nombreuses études ont rapporté une relation positive entre l’indice de masse corporelle (IMC) et l’incidence de l’asthme en particulier chez la femme. L’IMC est un indice global qui ne permet pas de distinguer la masse maigre de la masse grasse ni d’estimer la distribution régionale de l’adiposité. L’adiposité, en particulier abdominale, tend à augmenter avec l’âge au détriment de la masse maigre. Chez le sujet âgé, bien que fréquent et souvent sévère, l’asthme reste peu étudié.Matériel et Méthodes La relation entre le syndrome métabolique et la fonction ventilatoire (Volume Expiratoire Maximal Seconde, Capacité Vitale Forcée) a été étudiée à partir des données de 121965 sujets ayant bénéficié d’un examen périodique de santé au centre IPC à Paris entre 1999 et 2006. Une analyse en composantes principales a permis d’évaluer la part respective de chacun des paramètres du syndrome dans cette relation. Puis, l’étude du déclin de la fonction ventilatoire (VEMS) et de son lien avec l’adiposité abdominale a été conduite chez près de 10000 sujets du centre IPC réexaminés à 5 ans. Enfin, la relation entre l’adiposité abdominale et la prévalence et l’incidence de l’asthme a été analysée au sein de la cohorte des 3 Cités chez 7643sujets âgés de 65 ans et plus. Principaux résultats Le syndrome métabolique était associé à l’altération de la fonction ventilatoire (Odds Ratio ajusté, Intervalle de Confiance à 95%=1,28 [1,20-1,37] et ORa=1,41 [1,31-1,51], respectivement pour le VEMS et la CVF<Limite Inférieure de la Normale). Cette association reposait essentiellement sur la présence de l’obésité abdominale indépendamment entre autres de l’IMC et du statut tabagique chez l’homme comme chez la femme. Un déclin accéléré de la fonction ventilatoire était associé au gain d’adiposité abdominale (∆VEMS= -24,6 ; -29,0 ; -36,2 ml/an pour un tour de taille « diminué », « stable » et « augmenté », respectivement). Un risque augmenté d’asthme était associé au surpoids abdominal et à l’obésité abdominale dans les deux sexes (ORa, IC95%=1,30 [1,02-1,65] et 1,76 [1,31-2,36], respectivement). Conclusion Ces résultats apportent des arguments en faveur du rôle de l’obésité abdominale dans le développement des pathologies respiratoires chroniques. Nos résultats suggèrent que la mesure de la fonction ventilatoire pourrait aider à identifier les sujets à haut risque cardiométabolique. / Introduction The mechanisms underlying the relationship between lung function and the incidence of cardiovascular disease remain uncertain. Metabolic syndrome, a cluster of major cardiovascular risk factors including abdominal obesity, may play a role in this relationship. Data on the association between lung function and metabolic syndrome are sparse. Few data have been published on the relationship between abdominal obesity and the risk of asthma. Many studies have reported a positive relationship between body mass index (BMI) and the incidence of asthma particularly in women. BMI is a crude measure of obesity that does not discriminate between muscle and adipose tissue mass or estimate regional adiposity. Adiposity, and particularly visceral fat mass, tends to increase with aging at the expense of muscle mass and these changes in body composition make BMI an inadequate body fatness indicator. In the elderly, although frequent and often severe, asthma remains poorly studied.Materials and MethodsFirst, the relationship between metabolic syndrome and lung function (Forced expiratory volume in one second, Forced Vital Capacity) was studied using data from 121,965 patients who had a health examination at the Paris Investigations Préventives et Cliniques center between 1999 and 2006. A principal component analysis was used to investigate the differential associations between lung function and specific components of metabolic syndrome. Second, the study of lung function (FEV1) decline and its relationship with abdominal fat was conducted among nearly 10,000 subjects followed 5 years later at the IPC center. Third, the relationship between abdominal adiposity and prevalence and incidence of asthma was analyzed within the 3 Cities cohort study including 7,643 subjects aged 65 and over.Main resultsMetabolic syndrome was associated with impaired lung function (Adjusted Odds Ratio, 95% Confidence Interval=1.28 [1.20-1.37] et ORa=1.41 [1.31-1.51], for FEV1 and FVC<Lower Limit of Normal, respectively). This association was mainly due on the presence of abdominal obesity independently of BMI and smoking status in men as in women. An accelerated decline in lung function was associated with abdominal fat gain (∆VEMS= -24.6 ; -29.0 ; -36.2 ml/year for waist circumference « decreased», « stable » et « increased », respectively). An increased risk of asthma was associated with abdominal overweight and abdominal obesity in both sexes (ORa, IC95%=1.30 [1.02-1.65] and 1.76 [1.31-2.36], respectively).ConclusionThese results provide arguments for the role of abdominal obesity in the development of chronic lung diseases. Measurement of lung function may help to identify patients at cardiometabolic high risk.
158

Estudo do efeito de três exercícios de ioga na capacidade respiratória em pacientes com distrofia muscular progressiva tipo Duchenne (DMD) / Effects of three respiratory techniques of yoga in the respiratory function of patients with Duchenne?s progressive muscular dystrophy

Rodrigues, Marcos Rojo 31 August 2007 (has links)
A evolução da Distrofia Muscular de Duchenne (DMD) culmina na morte dos pacientes por problemas respiratórios, que aparentemente estão relacionados com a fraqueza de sua musculatura. O propósito deste estudo foi avaliar o efeito de três exercícios respiratórios de ioga na função respiratória em pacientes com DMD. A escolha dos exercícios foi motivada pelo fato de não se encontrar similares nos procedimentos fisioterápicos atuais no ocidente e por poderem ser praticados sem a necessidade de aparatos ou ajuda externa, facilitando sua execução diária. Os exercícios foram ensinados individualmente no ambulatório do Hospital das Clínicas da Universidade de São Paulo em dias regulares de consultas dos pacientes. As séries, bem como a sua progressão, levaram em consideração as limitações individuais. Foi realizada uma avaliação inicial das condições respiratórias (função pulmonar e pressões respiratórias) em 85 pacientes com idade entre 6 e 14 anos. Estas avaliações foram repetidas a cada 5 meses (em média) ao longo do treinamento. Os dados foram analisados de diferentes maneiras: pacientes que fizeram todas as avaliações ao longo de 10 meses (N=39); ao longo de 20 meses (N=18) e com os resultados dos pacientes que fizeram pelo menos uma avaliação além da inicial ao longo de 10 meses (N=70). Os grupos foram divididos por faixa etária em dois subgrupos (6 a 9 anos e 10 a 14 anos de idade). Constatou-se na análise com N=39 e N=70 que os pacientes mais novos que executaram os exercícios aplicados, apresentaram depois de 10 meses de treinamento, elevação nos valores absolutos e relativos da capacidade vital forçada (CVF), volume expiratório forçado em 1 segundo (VEF1) e pressão expiratória máxima (PEmax) e que os pacientes mais velhos, depois de 10 meses de treinamento, apresentaram melhora nos índices de pressão expiratória máxima (PEmax) em valores absolutos e relativos. Na análise com N=18 observou-se que os pacientes obtiveram melhora nos valores absolutos da função pulmonar (CVF e VEF1) até os 20 meses de treinamento quando comparamos com os valores do início e para a PEmax em valores absolutos, os resultados aumentam até 10 meses de treinamento e depois se mantém estáveis. Observou-se diminuição no declínio dos índices de função pulmonar dos pacientes quando comparados com crianças normais (porcentagem do predito). Constatou-se na análise determinada pela curva dos resultados da PEmax por faixa etária em valores relativos, que após 10 meses de prática dos exercícios de ioga, o declínio de seus valores foi retardado. O grande fator de melhora destes pacientes foi o aumento da força muscular expiratória forçada conseguido especialmente com a prática da técnica denominada kapalabhati. Recomendamos que estes exercícios sejam incorporados à prática clínica dos pacientes com DMD com a intenção de minimizar os danos causados pela perda da capacidade respiratória. / Duchenne Muscular Dystrophy (DMD) has a progression that culminates in the death of the patients for respiratory problems, which are apparently related to the weakness of the respiratory muscles. The objective of this study was to investigate the effects of three respiratory techniques of yoga in the respiratory function of patients with DMD. The selection of the exercises was conducted taking into account that there are no similar ones in the actual western physiotherapeutic procedures, and due to the fact that all of them may be practiced without the need of any apparatus or external help, making their daily practice easy. The exercises were taught individually in the Ambulatory of the General Hospital of the University of São Paulo during the regular appointments of the patients. The series of exercises, as well as their progressions, took into consideration the individual limitations. In order to establish the respiratory conditions (FVC, FEV1, PImax, and PEmax) of the group, an initial evaluation was conducted with 85 patients between 6 and 14 years old. The follow-up evaluations were carried out on an average 5-month interval, during the training period. Data were analyzed in different ways: subjects which had all the evaluations during 10 months of training (N=39); during 20 months of training (N=18) and with the results of patients that had at lest one evaluation besides the initial in the first 10 months (N=70). Furthermore, the total group was divided by age into 2 subgroups: (from 6 to 9 years old, and from 10 to 14 years old). The analysis of the groups with N=39, and N=70 revealed that, after 10 months of training, the younger subjects had increased their absolute and relative values of forced vital capacity (FVC), expiratory forced volume in 1 sec (FEV1), and maximal expiratory pressure (PEmax) , and that the older subjects, after the same period, had their absolute and relative PEmax also increased. In the analysis of the subgroup with N=18, there was an increase in the absolute values for pulmonary function (FVC and FEV1) until 20 months of training, while for PEmax this increase was seen only until 10 months, and afterwards there was a maintenance of its values. There was a reduction in the decline of the pulmonary function indexes of the patients when compared with healthy subjects (percentage of the predicted). The curve results of relative PEmax according to age revealed that after 10 months of practicing the prescribed exercises, the decline of its values was postponed. The greatest improvement in these children was found in the expiratory muscle power, attained through the practice of the technique called kapalabhati. We recommend the inclusion of these exercises to the clinical treatment of the DMD patients with the intention of minimizing the damage caused by the loss of respiratory capacity.
159

Avaliação da espirometria de gestantes expostas à poluição atmosférica da Região Metropolitana de São Paulo / Spirometric evaluation of pregnant women exposed to air pollution in the metropolitan region of São Paulo

Pastro, Luciana Duzolina Manfré 11 March 2015 (has links)
Introdução: A poluição do ar pode levar a alterações no sistema respiratório, especialmente entre certos grupos, como as gestantes, que são mais vulneráveis aos efeitos de poluentes atmosféricos. A gravidez é um período que envolve alterações funcionais e anatômicas no corpo da mulher, incluindo alterações na função pulmonar, o que pode ser avaliado por espirometria, um método simples, barato e eficaz. Objetivos: Os objetivos deste estudo foram a usar a espirometria para avaliar a função pulmonar de mulheres no primeiro trimestre (T1) e no terceiro trimestre (T3) de gravidez e analisar a influência da exposição a poluição do ar sobre os parâmetros espirométricos. Metodologia: O estudo foi realizado no Ambulatório de Obstetrícia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) entre Maio de 2011 e Agosto de 2013. Foram aplicados os seguintes critérios de inclusão: gestação única, idade gestacional no dia da primeira espirometria inferior a 13,86 semanas, ausência de doenças maternas préexistentes, preparação adequada para o teste de espirometria e amostradores passivos individuais (APIs) adequados para análise. Os critérios de exclusão foram a mudança de endereço, o aborto, o teste de espirometria inadequado e desistência de participar do projeto. Os APIs contendo dois filtros de celulose embebidos com solução absorvente para capturar os níveis de NO2 e outros dois filtros embebidos com solução de índigo blue para medir os níveis de O3 foram entregues às gestantes cerca de 12 dias antes da realização do teste de espirometria. Dados do relatório anual da Companhia Ambiental do Estado de São Paulo (CETESB) para o mesmo período dos amostradores passivos, foram utilizados. Para a espirometria, um espirômetro Koko foi utilizado, sendo considerada as duas melhores curvas para avaliar os resultados da função pulmonar. Análise estatística: Foi utilizado o teste Mann-Whitney para grupos independentes e Wilcoxon para os dependentes. Devido à pequena variação na exposição à poluição, a exposição no primeiro trimestre (Q1) e quarto trimestre (Q4) foram comparados para cada poluente em T1 e T3 através da análise nãoparamétrica para medidas repetidas. Resultados: Houve uma redução estatisticamente significativa dos valores absolutos (T1: 3,690 L; T3: 3,475 L) e preditos (T1: 101%, T3: 97,5%) da capacidade vital forçada (CVF), p < 0,0001. E uma redução estatisticamente significativa dos valores absolutos (T1: 3.080 L; T3: 2.950 L) e preditos (T1: 99%, T3: 96%) do volume expiratório forçado no primeiro segundo do procedimento (FEV1), p < 0,0001. A exposição à poluição foi semelhante em ambos os trimestres, exceto para a exposição de NO2 no API, o que foi inferior em T3 (p = 0,001). Independentemente do trimestre (T1 ou T3), o grupo de mulheres do Q4 (T1: 97,5%; T3: 98,5%) teve NO2 estatisticamente maior dos valores do fluxo expiratório forçado de 25 a 75% do procedimento (FEF25-75%) do que o grupo em Q1 (T1: 80%; T3: 92%). O grupo de mulheres do Q1 do NO2 teve um aumento significativo neste parâmetro de T1 a T3 (p = 0,042). Em termos de valores absolutos da relação FEV1/FVC, o grupo de mulheres no Q1 mostrou um aumento estatisticamente significativo neste parâmetro de T1 (0,810 L) para T3 (0,840 L) (p = 0,026). Em T3, os valores absolutos e relativos da CVF foram estatisticamente maiores para o grupo de gestantes do Q4 (3,535 L; 100,5%) de NO2 do que para o grupo de gestantes do Q1 (3,345 L; 92%). O grupo de gestantes do Q4 de O3 mostrou o VEF1 estatisticamente maior eno T1 (102,5%) do que no T3 (95,5%) (p < 0,001). Independentemente do trimestre, o grupo de gestantes do Q4 do MP10, teve valores absolutos da CVF (T1: 3.520 L; T3: 3,265 L) e os valores de VEF1 (T1: 2,915 L; T32.840 L) foram estatisticamente menor do que para o grupo em Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0,040; p = 0,035, respectivamente. Valores absolutos e preditos do pico de fluxo expiratório (PEF) em T1 das mulheres do Q4 (5,995 L; 80%) do MP10 foram estatisticamente menores do que para as mulheres no Q1 (6,675 L; 85%) (p = 0,006; p = 0,041 , respectivamente). Mulheres grávidas em Q4 (0,835 L) do MP10 tiveram os valores da relação VEF1/CVF estatisticamente menores valores do que as mulheres do Q1 (0,850 L) (p = 0,029). Conclusão: Exposição a NO2 e O3 foi associada com o aumento de alguns dos parâmetros de espirometria, indicando a presença de uma possível função de defesa pulmonar ou mecanismo compensatório em mulheres grávidas, quando expostos a esses poluentes. O MP10 foi associado com a redução de alguns parâmetros de espirometria durante a gravidez, indicando os efeitos danosos do poluente para a função do pulmão de mulheres grávidas / Introduction - Air pollution can lead to alterations to the respiratory system, particularly among certain groups, such as pregnant women, which are more vulnerable to the effects of air pollutants. Pregnancy is a period involving functional and anatomical changes in a woman\'s body. These changes include pulmonary function, which can be assessed by spirometry, a simple, inexpensive and effective method. Objectives - The aims of this study were to use spirometry to evaluate pulmonary function in pregnant women in the first trimester (T1) and the third trimester (T3) of pregnancy and to analyze the influence of air pollution exposure on the spirometry parameters. Methodology - This study was carried out at the Obstetrics Clinic of Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) between May 2011 and August 2013. The following inclusion criteria were applied: singleton pregnancy, 13.86 weeks gestational age at the first spirometry, no preexisting maternal diseases, adequate preparation for the spirometry test and individual passive samplers (IPAs) suitable for analysis. The exclusion criteria were change of address, abortion, inadequate spirometry testing and withdrawal from the project. The exposure to pollutants prior to the spirometry tests was assessed in T1 and T3. The passive samplers containing two cellulose filters soaked with absorbent solution to capture NO2 levels and two other filters soaked with indigo solution to measure O3 levels were provided to the pregnant women roughly 12 days prior to the spirometry test. Data from the environmental Company of São Paulo State (CETESB) annual report for the same period the passive samplers were used. For the spirometry, a Koko spirometer was used, taking the two best curves to assess lung function results. Statistical Analysis - We used Mann- Whitney tests for independent groups and Wilcoxon for the dependent ones. Due to the small variation in the exposure to pollution, exposure in the first quarter (Q1) and fourth quarter (Q4) were compared for each pollutant in T1 and T3 through non-parametrical analysis for repeated measurements. Results - It has been noted a significant statistical reduction of absolute and predicted forced vital capacity (FVC) values (3.690 L; 3.475 L) and forced expiratory volume during the first second of the procedure (FEV1) (3.080 L; 2.950 L) from T1 to T3. Exposure to pollution was similar in both trimesters, except for exposure to NO2 in the passive sampler, which was lower in T3 (p = 0.001). Regardless of the trimester (T1 or T3), the group of pregnant women in Q4 (97.5%; 98.5%) of NO2 had statistically higher predicted forced expiratory values of 25 to 75% of the procedure (FEF25-75%) than the group in Q1 (80%; 92%). Pregnant women in Q1 of NO2 had a significant increase in this parameter from T1 to T3 (p = 0.042). In terms of absolute FEV1/FVC values, pregnant women in Q1 showed a statistically significant rise in this parameter from T1 (0.810 L) to T3 (0,840 L) (p = 0,026). In T3, absolute and predicted FVC values were statistically higher for the group of pregnant women in Q4 (3.535 L; 100.5%) of NO2 than for the group of pregnant women in Q1 (3.345 L; 92%). Pregnant women in Q4 of O3 displayed statistically higher FEV1 values in T1 (102.5%) than in T3 (95.5%) (p < 0.001). Regardless of trimester, for the group of pregnant women in Q4 of MP10, absolute FVC (T1:3 .520 L; T3: 3.265 L) and FEV1 values (T1: 2.915 L; T3: 2.840 L) were statistically lower than for the group in Q1 (FVC - T1: 3.780 L; T3: 3.580 L) (FEV1 - T1: 3.180 L; T3: 3.065 L) p = 0.040; p = 0.035 respectively. Absolute and predicted peak expiratory flow (PEF) in T1 of pregnant women in Q4 (5.995 L; 80%) of MP10 were statistically lower than for the pregnant women in Q1 (6.675 L; 85%) (p = 0.006; p = 0.041, respectively). Pregnant women in Q4 (0.835 L) of MP10 displayed statistically lower absolute FEV1/FVC values than the pregnant women in Q1 (0.850 L) (p = 0.029). Conclusion - Exposure to NO2 and O3 was associated with the increase in some of the spirometry parameters, indicating the presence of a possible lung function defense or compensatory mechanism in pregnant women when exposed to those pollutants. The MP10 was associated with the reduction of some spirometry parameters during pregnancy, indicating the harmful effects of that pollutant to the lung function of pregnant women
160

Efeito da fisioterapia respiratória no pós-operatório imediato, em pacientes submetidos à cirurgia abdominal alta: estudo prospectivo / Effect of respiratory physical therapy on immediate postoperative in patients submitted to high abdominal surgery: prospective study

Manzano, Roberta Munhoz 17 March 2006 (has links)
Introdução: A piora da função muscular respiratória pós-cirurgia aumenta o risco de hipoventilação, hipóxia, atelectasia e infecções. O fisioterapeuta tem um papel essencial na recuperação desses pacientes. O objetivo da pesquisa foi avaliar se a intervenção da fisioterapia respiratória no pós-operatório imediato de pacientes submetidos à cirurgia abdominal alta eletiva, em sala de recuperação pós-anestésica, resulta em melhor função pulmonar, observando valores de espirometria e oximetria de pulso e dados da evolução clínica. Métodos: O estudo é do tipo ensaio clínico prospectivo e aleatorizado observando-se valores de espirometria e oximetria de pulso. Também foi realizada análise retrospectiva dos prontuários. Os grupos foram avaliados no pré-operatório e no segundo pós-operatório (espirometria, oximetria de pulso, exame físico, escala analógica de dor). O grupo experimental recebeu fisioterapia respiratória na recuperação pós-anestésica. Resultados: Não houve diferença entre os valores espirométricos, de pico de fluxo expiratório e de saturação de oxigênio entre os grupos controle e experimental. No presente estudo a saturação de oxigênio melhorou após a fisioterapia (p=0,029). Porém essa melhora não se manteve até o segundo pós-operatório. Também foi avaliado o tempo de internação, tempo cirúrgico, escala analógica de dor e complicações pós-operatórias, não houve diferenças entre os grupos. Conclusões: A espirometria não se mostrou sensível para detectar eventual piora da função pulmonar no segundo pós-operatório. A saturação de oxigênio atingiu números próximos aos do pré-operatório após exercícios de fisioterapia. A fisioterapia respiratória no pós-operatório imediato não causou dor ao paciente / Introduction: Surgical procedures can affect the respiratory muscles increasing the risks to hypoventilation, hypoxia, atelectasis and infections. Physiotherapists are essentials to care those patients. The purpose of this study was to evaluate the intervention of chest physiotherapy in immediate postoperative, in anesthesia recovery period room, analyzing lung functions, spirometry and oximetry in patients submitted to elective abdominal surgery. Methods: Clinic prospective and arbitrary, observing spirometry and oxygen saturation. A retrospective analysis from the notes was also done. The groups were evaluated in preoperative and 2nd postoperative (spirometry, oxygen saturation, physic examination and graduated pain scale).The physiotherapy group received chest physiotherapy in recuperation post anaesthetic. Results: There is no evidence to support a significant difference between control group and physiotherapy group analyzing spirometric values, expiratory peak flow and oxygen saturation. The oxygen saturation improves after physical therapy (p=0,029). But this improve can\'t kept until second postoperative. The period in hospital, surgery duration, graduated pain scale and postoperative pulmonary complications were analyzed but there was not significant difference between groups. Conclusions: Spirometry was not able to show a possible worst in pulmonary function on the second postoperative. The oxygen saturation reached similar numbers to preoperative post chest physiotherapy. In immediate postoperative chest physiotherapy do not cause pain to the patient

Page generated in 0.0523 seconds