• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 82
  • 47
  • 19
  • 3
  • 2
  • Tagged with
  • 150
  • 87
  • 49
  • 42
  • 34
  • 34
  • 34
  • 33
  • 32
  • 19
  • 18
  • 16
  • 15
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Radon: Vorkommen - Wirkung - Schutz

14 September 2021 (has links)
In der Broschüre erhalten Sie Informationen zu den Eigenschaften, sein Vorkommen und Empfehlungen für den Umgang mit Radon. Radon ist ein radioaktives Edelgas. Es ist natürlichen Ursprungs und wird hauptsächlich aus dem Boden in die Luft freigesetzt. Deshalb wird Radon vom Menschen eingeatmet und kann Lungenkrebs verursachen. Der Mensch kann sich vor den schädlichen Wirkungen durch geeignete Maßnahmen schützen. Redaktionsschluss: 26.03.2019
112

Umweltradioaktivität - Messung und Überwachung

16 September 2021 (has links)
Radioaktivität gibt es auf der Erde seit ihrer Entstehung und kommt im gesamten Lebensumfeld vor. Derzeit sind ca. 70 natürliche und weit über tausend künstlich erzeugte Radionuklide bekannt. Über einen bestimmten Zeitraum [z. B. eine Stunde (h), ein Jahr (a)], einer Strahlung ausgesetzt sein, heißt exponiert werden. Diese auf den menschlichen Körper einwirkende Strahlenexposition bewirkt die Aufnahme von Strahlungsenergie, die bei Wechselwirkung von Strahlung mit dem Körpergewebe an dieses abgegeben wird. In dieser Publikation wird das Vorkommen von Radioaktivität in der Umwelt und seine unterschiedlichen Auswirkungen auf den Menschen in Sachsen dargestellt. Sie ist eine Einführung in das Thema und richtet sich an die breite Öffentlichkeit. Redaktionsschluss: 30.09.2014
113

Berechnungen im Walzwerksbau

Merz, Jürgen, Münker, Jochen 10 May 2012 (has links)
Zusammenfassung Herr Merz: - Auf Basis von gerechneten Stützstellen können beliebige Flachzapfengeometrien innerhalb des Stützbereichs über den Ansatz {Durchmesser^3} umgerechnet werden. - Einfaches und schnelles Programm zur Bestimmung der Vergleichsspannung im Übergang vom Flachzapfenquerschnitt auf Rundquerschnitt - Ergebnisse stimmen sehr gut mit FE-Analysen überein. Zusammenfassung Herr Münker: Ausgehend von einem 2D-FEM-Modell werden mit dem FEM-Programm MSC.Marc der Wärmeeintrag in eine Rolle sowie die transienten Temperatur- und Spannungsfelder berechnet. Anschließend werden vergleichende 2D-FEM-Berechnungen mit den Programmen Mechanica Thermal und Structure durchgeführt. Die Erweiterung auf 3D-FEM-Berechnungen und die Ermittlung der Wärmespannungen in der Rolle schließen den Vortrag ab.
114

Translation and optimization of a gamma H2AX foci assay for the prediction of intrinsic radiation sensitivity

Rassamegevanon, Treewut 27 May 2020 (has links)
Radiotherapy remains one of the most important treatment modalities for cancer therapy. Malignant tumors show an extended spectrum of intrinsic radiation sensitivity even among tumors of the same entity or with similar histological features. Predicting intrinsic radiation sensitivity might improve treatment outcome and allow individualized treatment. Hence, an assay that provides a predictive information of the tumor’s intrinsic radiation sensitivity is of great need. Histone H2AX, a histone variant of histone H2A family, is rapidly phosphorylated upon DNA double strand break (DSB) induction resulting in gamma H2AX (γH2AX). Gamma H2AX accumulates at DNA DSB sites and subsequently recruits DNA damage repair factors. Formation of γH2AX is visualized by an immunohistology-based approach and detected as foci under an epifluorescent microscope. Gamma H2AX foci represent DNA DSBs, while residual γH2AX foci (foci detected 24 h post irradiation) are considered as unrepaired damages. In previous studies, the γH2AX foci assay showed a high potential as a predictive method for radiosensitivity. This thesis aims to further translate and optimize the ex vivo γH2AX foci assay for a clinical applicability. In this study, all experiments were performed using human head and neck squamous cell carcinoma (hHNSCC) xenograft models. For ex vivo investigations, tumors on the hind legs of nude mice were excised and cut into multiple pieces, or fine-needle biopsies of the tumors were taken. Tumor biopsies were reoxygenated in culture medium for 10 h or 24 h followed by radiation exposure of 0 8 Gy. Tumor biopsies were fixed and embedded in paraffin 24 h post irradiation. For the γH2AX foci assay under in vivo conditions, tumors-bearing mice were irradiated with single doses of 0 8 Gy. Tumors were excised, fixed, and paraffin embedded 24 h post irradiation. Manual quantification of γH2AX foci was performed exclusively in perfused areas, which were identified by pimonidazole (hypoxic marker) and BrdU (proliferation marker) staining. Foci number was corrected, normalized, and statistically analyzed by a linear mixed effects model (LMEM), linear regression model or analysis of covariance. To investigate tumor heterogeneity in the ex vivo γH2AX foci assay, γH2AX foci were enumerated in four equally treated tumor specimens per group i.e. unirradiated and ex vivo irradiated with 4 Gy. Strong intratumoral heterogeneity in γH2AX foci was determined with a minor intertumoral heterogeneity. No significant effect of reoxygenation between 10 h or 24 h was observed, enhancing clinical practicability of the assay. The effect of experimental settings was studied by analyzing data from this study (ex vivo) and from comparable published data (in vivo) with LMEM. Radiation induced nuclear area alteration was detected in some of the evaluated tumor models in under both experimental conditions. A greater intra and intertumoral heterogeneity were observed in the ex vivo set up compared to the in vivo set up. Radiation response determined by the γH2AX foci assay in ex vivo irradiated biopsies and in the corresponding in vivo irradiated tumors was evaluated. Between in vivo and ex vivo, four out of five tumor models showed comparable slopes of dose response curves (SDRC) of normalized and corrected γH2AX foci. SDRC of normalized γH2AX foci was able to classify tumors according to their intrinsic radiation sensitivity (TCD50). In conclusion, the ex vivo γH2AX foci assay holds a promising potential for predicting radiation sensitivity in solid tumors. The comparable radiation response assessed by γH2AX foci of in vivo irradiated tumors and the matching ex vivo irradiated tumor biopsies supports clinical applicability of the assay. Using SDRC of γH2AX foci as a predictor of radiosensitivity, radioresistant and radiosensitive tumors could be classified. The significant intratumoral heterogeneity in the ex vivo γH2AX foci assay suggests a limited representativeness of a single biopsy for radiosensitivity prediction. Additionally, the change of tumor microenvironment modulated cellular adaptation and DNA damage repair capability. The outcomes suggested that a sufficient number of cells, regions of interest, and biopsies are required to obtain a solid prediction.:Contents List of Abbreviations List of Figures List of Tables 1. Introduction 1.1 Effect of ionizing radiation on cellular level 1.1.1 Radiation induces cell death 1.1.2 Cell-cycle arrest mediated by radiation 1.2 DNA damage repair 1.2.1 Non homologous end joining (NHEJ) 1.2.2 Homologous recombination (HR) 1.2.3 Base damage repair and single strand break repair 1.2.4 Role of γH2AX in DNA damage repair 1.3 Prediction of tumor radioresponsiveness 1.3.1 Prediction of tumor radiation sensitivity by γH2AX 2 Tumor heterogeneity determined with a γH2AX foci assay: A study in human head and neck squamous cell carcinoma (hHNSCC) 2.1 Summary of the publication 3 Heterogeneity of γH2AX foci increases in ex vivo biopsies relative to in vivo tumors. 3.1 Summary of the publication 4 Comparable radiation response of ex vivo and in vivo irradiated tumor samples determined by residual γH2AX foci 4.1 Summary of the manuscript 5 Discussion 5.1 Tumor heterogeneity in γH2AX foci assay 5.2 Alteration of nuclear area post irradiation 5.3 Clinical relevance of the γH2AX foci assay 5.4 Technical challenges and limitations of the assay 5.5 Conclusion and Outlook 6 Abstract 7 Zusammenfassung 8 Bibliography Acknowledgement Appendices Part A: Materials A.1 Tumor lines A.2 Chemicals and Materials A.3 Devices and Software Part B: Supplementary materials B.1 Supplementary materials of publication I B.2 Supplementary materials of publication II B.3 Supplementary materials of manuscript
115

Dosimetry of Highly Pulsed Radiation Fields

Gotz, Malte 21 March 2018 (has links)
Durch die Einführung von Synchrozyklotronen und Laser-Teilchenbeschleunigern, entwickelt mit dem Ziel günstigere und kompaktere Protonentherapieanlagen bereitzustellen, werden stark gepulste Strahlenfelder möglicherweise Anwendung in der Teletherapie finden. Darüber hinaus bergen stark gepulste Strahlenfelder das Potential klinischer Vorteile durch eine bessere Schonung gesunden Gewebes oder die verbesserte Behandlung bewegter Tumore. Allerdings ergeben sich neue Herausforderungen im Bereich der Dosimetrie, der Grundlage für eine präzise therapeutische Anwendung ionisierender Strahlung. Diese Herausforderungen betreffen sowohl den Bereich der klinischen Dosimetrie für die unmittelbare Strahlenanwendung als auch die Strahlenschutzdosimetrie zum Schutz von Umwelt und Personal. Luftgefüllte Ionisationskammern, die primären Messinstrumente der klinischen Dosimetrie, sind von einem zunehmenden Signalverlust aufgrund von Volumenrekombination betroffen, da stark gepulste Strahlenfelder eine hohe Ionisationsdichte innerhalb eines sehr kurzen Zeitraums erzeugen. Beschreibungen für diese Effekte sind zwar gut etabliert für die moderat gepulsten Felder im gegenwärtigen klinischen Einsatz (Boags Theorie), allerdings sind die dafür nötigen Näherung höchst wahrscheinlich unzureichend für die stark gepulsten Strahlenfelder zukünftiger Beschleuniger. Ferner sind Dosisleistungsmessgeräte, welche im Strahlenschutz als fest installierte oder mobile Überwachungsdosimeter eingesetzt werden, nur für kontinuierliche Strahlenfelder geprüft und bauartzugelassen, was Zweifel an ihrer Eignung für die Messung gepulster Felder eröffnet. In dieser Arbeit wurden beide Bereiche der Dosimetrie, sowohl Strahlenschutz als auch klinische Dosimetrie, untersucht, um die medizinische Anwendung stark gepulster Strahlung zu ermöglichen. Für ein möglichst umfassendes Verständnis wurden dabei experimentelle Untersuchungen mit theoretischen Überlegungen und Entwicklungen verzahnt. Mit dem ELBE-Forschungsbeschleuniger wurde ein gepulster 20 MeV Elektronenstrahl und somit ein gepulstes Strahlungsfeld erzeugt, welches eine systematische Untersuchung in einem großen Bereich in Bezug auf Pulsdosis und Pulsdauer erlaubte. Ionisationskammern für den klinischen Einsatz wurden mit diesem Elektronenstrahl direkt bestrahlt und ein Faraday-Becher diente als unabhängige Referenzmessung. Dosisleistungsmessgeräte hingegen wurden im, durch den Elektronenstrahl im Faraday-Becher erzeugten, Bremsstrahlungsfeld bestrahlt. Dabei fungierte die Ionisationskammer vor dem Faraday-Becher als Strahlmonitor und diente zur Bestimmung der Referenzdosis des Bremsstrahlungsfeldes über eine Querkalibrierung mit Thermolumineszenzdosimetern. Es wurden drei Dosisleistungsmessgeräte basierend auf unterschiedlichen Messprinzipien untersucht, die damit einen großen Teil der im Strahlenschutz eingesetzten Messprinzipien abdecken: Die Ionisationskammer RamION, das Proportionalzählrohr LB1236-H10 und der Szintillationsdetektor AD-b. Für die klinische Dosimetrie wurden zwei verbreitete Ionisationskammergeometrien untersucht: die Advanced Markus Kammer als Flachkammer und die PinPoint Kammer als Kompaktkammer. Zusätzlich zu der üblichen Luftfüllung wurde außerdem eine Füllung mit reinem Stickstoff und zwei Flüssigionisationskammern mit Isooctan und Tetramethylsilan untersucht. Ferner wurde eine numerische Berechnung der Volumenrekombination in Ionisationskammern durch die Beschreibung der Prozesse von Ladungsfreisetzung, Ladungstransport und Reaktion entwickelt, um eine Beschreibung zu erhalten, die ohne die für Boags Theorie notwendigen Näherungen auskommt. Insbesondere berücksichtigt diese Berechnung den Einfluss der freigesetzten Ladungen auf das elektrische Feld, der in Boags Theorie vernachlässigt wird. Von den drei untersuchten Dosisleistungsmessgeräten zeigte nur das RamION Messungen innerhalb der gegebenen Toleranzen in den untersuchten Strahlungsfeldern. Die unerwartet schlechte Präzision des AD-b Szintillationsdetektors, der keinen prinzipiellen Beschränkungen in gepulsten Feldern unterliegen sollte, wurde auf die Signalverarbeitung im Messgerät zurückgeführt, welche das prinzipielle Problem einer unbekannten Signalverarbeitung in kommerziellen Geräten hervorhebt. Das LB 1236-H10 Proportionalzählrohr andererseits maß den Erwartungen entsprechend. Dies unterstützt zwar die in DIN IEC/TS 62743 dargelegten Erwartungen für zählende Dosimeter, zeigt allerdings zugleich die allgemeine Unzulänglichkeit solcher Instrumente für die Messung stark gepulster Felder und demonstriert die Notwendigkeit für weitere normative Bestrebungen, um einheitliche Bedingungen für die Untersuchung nicht-zählender Dosimeter (wie das RamION) zu schaffen. Durch die Aufnahme dieser Ergebnisse in die Literatur der Strahlenschutzkommission wurde hier der Grundstein für eine solche Entwicklung gelegt. Die Untersuchung der Ionisationskammern für klinische Dosimetrie zeigte z.T. starke Abweichungen zwischen Boags Theorie und experimentellen Beobachtungen. Boags Theorie beschreibt Volumenrekombination hinreichend genau lediglich für die zwei Flüssigionisationskammern. Im Falle sämtlicher gasgefüllter Kammern waren effektive Parameter notwendig, deren Wert kaum einen Zusammenhang mit der ursprünglichen Definition besaß. Doch auch dieser Ansatz versagt jedoch für die Advanced Markus-Kammer bei Sammelspannungen ≥ 300 V und Pulsdosen ab ca. 100 mGy. Das entwickelte numerische Berechnungsverfahren lieferte eine deutlich passendere Berechnung der Volumenrekombination und ermöglichte es, die Ursache für die Unterschiede zu Boags Theorie in dem Einfluss der freigesetzten Ladungen auf das elektrische Feld zu identifizieren. Eine aufgrund der erhöhten Pulsdosis erhöhte positive Raumladung verlangsamt die Sammlung der normalerweise schnellen freien Elektronen, welche von Volumenrekombination zunächst unbeeinträchtigt sind. Aufgrund der längeren Verweildauer im Kammervolumen, lagert sich jedoch ein höherer Anteil der Elektronen an und bildet negative Ionen. Der daraus resultierende höhere Anteil an Ladungen die Volumenrekombination ausgesetzt sind, zusätzlich zu der erhöhten Ladungsmenge, bedingt eine Erhöhung der Volumenrekombination mit der Pulsdosis, die sich nicht durch Boags Theorie beschreiben lässt. Insbesondere von Bedeutung ist dieser Effekt bei hohen elektrischen Feldstärken und kleinen Elektrodenabständen, die in einem hohen Anteil freier Elektronen resultieren. Des Weiteren erlaubt das numerische Verfahren die Berechnung für beliebige Pulsdauern, wohingegen Boags Theorie auf verschwindend geringe Pulsdauern beschränkt ist. Im Allgemeinen ergab das numerische Berechnungsverfahren Ergebnisse in guter Übereinstimmung mit den experimentellen Beobachtungen für die sehr verschiedenartigen Füllungen von Luft, Stickstoff und Flüssigkeiten. Auch die geometrisch komplexere Kompaktkammer konnte prinzipiell damit beschrieben werden, wobei sich jedoch für die untersuchte PinPoint-Kammer einige Diskrepanzen zu den experimentellen Beobachtungen ergaben. Eine vielversprechende Weiterentwicklung der Berechnung wäre die verbesserte Beschreibung der Sammelspannungsabhängigkeit der Volumenrekombination. In ihrer derzeitigen Form erfordert die Berechnung eine Charakterisierung jeder Kammer und Spannung, was durch eine Weiterentwicklung der Berechnung möglicherweise eliminiert werden könnte. Nichtsdestotrotz stellt die entwickelte numerische Berechnung eine deutliche Verbesserung gegenüber Boag's Theorie durch die korrekte Beschreibung der Pulsdosis- und Pulsdauerabhängigkeit der Volumenrekombination in stark gepulsten Felder dar, was prinzipiell eine absolute Dosimetrie dieser Felder ermöglichen sollte.:1 Introduction 2 Scientific Background 2.1 General Aspects of Dosimetry 2.1.1 The Radiation Dose 2.1.2 Limitations of Absorbed Dose 2.1.3 Radiation Therapy vs. Radiation Protection 2.2 Pulsed Radiation 2.2.1 Terminology 2.2.2 Sources 2.3 Ionization Chambers for Radiation Therapy Dosimetry 2.3.1 Principle of Operation 2.3.2 Calibration and Correction Factors 2.3.3 Saturation Correction and Volume Recombination 2.4 Numerical Solution of Advection-Diffusion-Reaction Equations 2.5 Dose Rate Meters for Radiation Protection Dosimetry 2.5.1 Counting Tubes 2.5.2 Scintillation Detectors 2.5.3 Current Regulatory Developments 3 Material and Methods 3.1 Common Experimental Setup 3.1.1 Radiation Source ELBE 3.1.2 Beam Monitoring Equipment 3.2 Dose Rate Meter Measurements 3.2.1 Measurement Series and Procedure 3.2.2 Reference Measurements 3.3 Ionization Chamber Measurements 3.3.1 Measurement Series and Procedure 3.3.2 Experimental Determination of Volume Recombination 3.4 Numerical Calculation of Volume Recombination 3.4.1 Plane-parallel Chamber Geometry 3.4.2 Adaption to Thimble Chamber Geometry 3.4.3 Input Parameters 4 Dose Rate Meter Investigation 4.1 Results 4.2 Discussion and Conclusion 5 Ionization Chamber Investigation 5.1 Field Homogeneity and Stability 5.2 Uncertainty Considerations 5.3 Advanced Markus Chamber in Air 5.3.1 Experimental and Calculation Results 5.3.2 Comparison to Literature 5.3.3 Validity of the Numerical Model 5.3.4 Discussion of the Recombination Rate 5.3.5 Relevance of the Free Electron Fraction 5.4 Advanced Markus Chamber in N 2 5.4.1 Experimental and Calculation Results 5.4.2 Discussion of the Electron-Ion Recombination 5.5 PinPoint Chamber 5.5.1 Results and Discussion 5.6 Liquid Ionization Chamber 5.6.1 Experimental and Calculation Results 5.6.2 Discussion 5.7 Conclusion and Outlook 6 Summary 7 Zusammenfassung Bibliography Appendix A Evaluation of the Faraday Cup Data B Description of the Implemented Numerical Solver Danksagung / Synchrocyclotrons and laser based particle accelerators, developed with the goal to enable more compact particle therapy facilities, may bring highly pulsed radiation field to external beam radiation therapy. In addition, such highly pulsed fields may be desirable due to their potential clinical benefits regarding better healthy tissue sparing or improved gating for moving tumors. However, they pose new challenges for dosimetry, the corner stone of any application of ionizing radiation. These challenges affect both clinical and radiation protection dosimetry. Air-filled ionization chambers, which dominate clinical dosimetry, face the problem of increased signal loss due to volume recombination when a highly pulsed field liberates a large amount of charge in a short time in the chamber. While well established descriptions exist for this volume recombination for the moderately pulsed fields in current use (Boag's formulas), the assumptions on which those descriptions are based will most likely not hold in the prospective, highly pulsed fields of future accelerators. Furthermore, ambient dose rate meters used in radiation protection dosimetry as survey meters or fixed installations are generally only tested for continuous fields, casting doubt on their suitability to measure pulsed fields. This thesis investigated both these aspects of dosimetry - clinical as well as radiation protection - to enable the medical application of highly pulsed radiation fields. For a comprehensive understanding, experimental investigations were coupled with theoretical considerations and developments. Pulsed fields, varying in both dose-per-pulse and pulse duration over a wide range, were generated with the ELBE research accelerator, providing a 20 MeV pulsed electron beam. Ionization chambers for clinical dosimetry were investigated using this electron beam directly, with an aluminium Faraday cup providing the reference measurement. Whereas the dose rate meters were irradiated in the photon field generated from stopping the electron beam in the Faraday cup. In those measurements, the reference was calculated from the ionization chamber, then serving a an electron beam monitor, cross-calibrated to the photon field with thermoluminescent dosimeters. Three dose rate meters based on different operating principles were investigated, covering a large portion of the operating principles used in radiation protection: the ionization chamber based RamION, the proportional counter LB 1236-H10 and the scintillation detector AD-b. Regarding clinical dosimetry, measurements of two prominent ionization chamber geometries, plane-parallel (Advanced Markus chamber) and thimble type (PinPoint chamber), were performed. In addition to common air-filled chambers, chambers filled with pure nitrogen and two non-polar liquids, tetramethylsilane and isooctane, were investigated. In conjunction with the experiments, a numerical solution of the charge liberation, transport, and recombination processes in the ionization chamber was developed to calculate the volume recombination independent of the assumptions necessary to derive Boag's formulas. Most importantly, the influence of the liberated charges in the ionization chamber on the electric field, which is neglected in Boag's formulas, is included in the developed calculation. Out of the three investigated dose rate meters only the RamION could be identified as an instrument truly capable of measuring a pulsed field. The AD-b performed below expectations (principally, a scintillator is not limited in detecting pulsed radiation), which was attributed to the signal processing, emphasizing the problem of a typical black-box signal processing in commercial instruments. The LB 1236-H10, on the other hand, performed as expected of a counting detector. While this supports the recent effort to formalize these expectations and standardize testing for counting dosimeters in DIN IEC/TS 62743, it also highlights the insufficiency of counting detectors for highly pulsed fields in general and shows the need for additional normative work to establish requirements for dose rate meters not based on a counting signal (such as the RamION), for which no framework currently exists. With these results recognized by the German radiation protection commission (SSK) the first steps towards such a framework are taken. The investigation of the ionization chambers used in radiation therapy showed severe discrepancies between Boag's formulas and the experimentally observed volume recombination. Boag's formulas describe volume recombination truly correctly only in the two liquid-filled chambers. All the gas-filled chambers required the use of effective parameters, resulting in values for those parameters with little to no relation to their original meaning. Even this approach, however, failed in the case of the Advanced Markus chamber for collection voltages ≥ 300 V and beyond a dose-per-pulse of about 100 mGy. The developed numerical model enabled a much better calculation of volume recombination and allowed the identification of the root of the differences to Boag's formulas as the influence of the liberated charges on the electric field. Increased positive space charge due to increased dose-per-pulse slows the collection and reduces the fraction of fast, free electrons, which are unaffected by volume recombination. The resultant increase in the fraction of charge undergoing volume recombination, in addition to the increase in the total amount of charge, results in an increase in volume recombination with dose-per-pulse that is impossible to describe with Boag's formulas. It is particularly relevant in the case of high electric fields and small electrode distances, where the free electron fraction is large. In addition, the numerical calculation allows for arbitrary pulse durations, while Boag's formulas apply only to very short pulses. In general, the numerical calculation worked well for plane-parallel chambers, including those filled with the very diverse media of liquids, nitrogen and air. Despite its increased complexity, the thimble geometry could be implemented as well, although, in the case of the PinPoint chamber, some discrepancies to the experimental data remained, probably due to the required geometrical approximations. A possible future development of the numerical calculation would be an improved description of the voltage dependence of the volume recombination. At the moment it requires characterizing a chamber at each desired collection voltage, which could be eliminated by an improved modeling of the volume recombination's dependence on collection voltage. Nevertheless, the developed numerical calculation presents a marked improvement over Boag's formulas to describe the dose-per-pulse dependence and pulse duration dependence of volume recombination in ionization chambers, in principle enabling the application of ionization chambers in the absolute dosimetry of highly pulsed fields.:1 Introduction 2 Scientific Background 2.1 General Aspects of Dosimetry 2.1.1 The Radiation Dose 2.1.2 Limitations of Absorbed Dose 2.1.3 Radiation Therapy vs. Radiation Protection 2.2 Pulsed Radiation 2.2.1 Terminology 2.2.2 Sources 2.3 Ionization Chambers for Radiation Therapy Dosimetry 2.3.1 Principle of Operation 2.3.2 Calibration and Correction Factors 2.3.3 Saturation Correction and Volume Recombination 2.4 Numerical Solution of Advection-Diffusion-Reaction Equations 2.5 Dose Rate Meters for Radiation Protection Dosimetry 2.5.1 Counting Tubes 2.5.2 Scintillation Detectors 2.5.3 Current Regulatory Developments 3 Material and Methods 3.1 Common Experimental Setup 3.1.1 Radiation Source ELBE 3.1.2 Beam Monitoring Equipment 3.2 Dose Rate Meter Measurements 3.2.1 Measurement Series and Procedure 3.2.2 Reference Measurements 3.3 Ionization Chamber Measurements 3.3.1 Measurement Series and Procedure 3.3.2 Experimental Determination of Volume Recombination 3.4 Numerical Calculation of Volume Recombination 3.4.1 Plane-parallel Chamber Geometry 3.4.2 Adaption to Thimble Chamber Geometry 3.4.3 Input Parameters 4 Dose Rate Meter Investigation 4.1 Results 4.2 Discussion and Conclusion 5 Ionization Chamber Investigation 5.1 Field Homogeneity and Stability 5.2 Uncertainty Considerations 5.3 Advanced Markus Chamber in Air 5.3.1 Experimental and Calculation Results 5.3.2 Comparison to Literature 5.3.3 Validity of the Numerical Model 5.3.4 Discussion of the Recombination Rate 5.3.5 Relevance of the Free Electron Fraction 5.4 Advanced Markus Chamber in N 2 5.4.1 Experimental and Calculation Results 5.4.2 Discussion of the Electron-Ion Recombination 5.5 PinPoint Chamber 5.5.1 Results and Discussion 5.6 Liquid Ionization Chamber 5.6.1 Experimental and Calculation Results 5.6.2 Discussion 5.7 Conclusion and Outlook 6 Summary 7 Zusammenfassung Bibliography Appendix A Evaluation of the Faraday Cup Data B Description of the Implemented Numerical Solver Danksagung
116

A Search for Extended Gamma-Ray Emission from the Galactic Center with VERITAS

Kelley-Hoskins, Nathan 07 May 2020 (has links)
Dunkle Materie bindet etwa 24 % der gesamten Energie im Universum. Bis heute ist jedoch dessen Ursprung nicht bekannt. Untersuchungen von Galaxien und kosmologischen Messungen deuten auf Dunkle Materie hin. Ein Kandidat für Dunkle Materie ist das sogenannte Weakly Interactive Massive Particle (WIMP), welches nur der Schwerkraft und der schwachen Wechselwirkung unterliegt. Eines dieser supersymmetrischen Teilchen ist das Neutralino. Das Ziel dieser Arbeit ist es, nach Dunkler Materie in dieser Form zu suchen. Aufgrund seiner Nähe sowie der hohen Dichte an Dunkler Materie bietet das Zentrum unserer Galaxie besondere Möglichkeiten zur Suche nach diesen Teilchen. Es wird vermutet, dass Neutralinos miteinander wechselwirken, dabei in Teilchen des Standard Modells zerfallen und so Photonen mit hohen Energien entstehen. Die Suche nach hochenergetischen Gammastrahlen in der Nähe des Galaktischen Zentrums kann folglich das Rätsel der Dunklen Materie lösen. Das Gammastrahlenobservatorium VERITAS hat das Galaktische Zentrum für etwa 108 Stunden beobachtet. Diese Daten wurden mittels einer unbinned Likelihood-Analyse auf die Existenz von Dunkler Materie untersucht. Da VERITAS das Galaktische Zentrum bei geringer Elevation beobachtet, können nur Gammastrahlen in einem Energiebereich zwischen 4 und 70 TeV detektiert werden. Die Analysemethode modelliert sowohl die räumliche Verteilung der Dunklen Materie als auch das Gammastrahlenspektrum. Der Beitrag der Gammastrahlen, welcher nicht von Dunkler Materie erzeugt wird, ist mittels einer punktförmigen Quelle modelliert. Zum Schluss wird der Untergrund mit realen Daten außerhalb des Galaktischen Zentrums abgeschätzt. Im Energiebereich zwischen 4 und 100 TeV wurden keine Signale der Dunklen Materie gefunden. Obere Grenzwerte für den Wechselwirkungsquerschnitt der WIMPs ergeben ⟨σv⟩ < (6.6 − 7.6) × 10−25 cm^3 oberhalb von 70 TeV in einem 95-prozentigen Erwartungsintervall. / Dark matter accounts for 24% of the universe’s energy, but the form in which it is stored is currently unknown. Understanding what form this matter takes is one of the major unsolved mysteries of modern physics. Much evidence exists for dark matter in the measurements of galaxies, dwarf galaxies, galaxy clusters, and cosmological measurements. One theory posits dark matter is a new undiscovered particle that only interacts via gravity and the weak force, called a weakly interacting massive particle (WIMP). One WIMP candidate is a supersymmetric particle called a neutralino. The objective of this thesis is to search for these dark matter particles, and attempt to measure their mass and cross section. Dark matter particles appear to concentrate in most galaxy-scale gravitational wells. One region of space that is both nearby and assumed to have a high density of dark matter is the center of our own galaxy. The neutralino is expected to annihilate into Standard Model particles, which may decay into photons. Therefore, a search for gamma rays near the Galactic Center may uncover the presence of dark matter. 108 hours of VERITAS gamma-ray observations of the Galactic Center are used in an unbinned likelihood analysis to search for dark matter. The Galactic Center’s low elevation results in VERITAS observing gamma rays in the 4–70 TeV energy range. The analysis used in this thesis consists of modeling the halo of dark matter at the Galactic Center, as well as the spectrum of gamma rays produced when two WIMPs annihilate. A point source is added to model the non-dark-matter gamma-ray emission detected from the Galactic Center. Background models are constructed from data of separate off-Galactic-Center observations. No dark matter signal is found in the 4–100 TeV mass range. Upper limits on the WIMP’s velocity-averaged cross section have been calculated, which above 70 TeV result in new limits of ⟨σv⟩ < (6.6 − 7.6) × 10−25 cm3 at the 95% confidence level.
117

Effekte einzelbaumweise eingemischter einheimischer Eichen in Wäldern der Gemeinen Kiefer (Pinus sylvestris L.) auf Standorten geringer Trophie und Wasserversorgung im Süden Brandenburgs

Lehmann, Bernd 28 November 2007 (has links)
Das Forschungsvorhaben hat das Ziel den Einfluss einzelbaumweise eingemischter einheimischer Eichen in Wäldern der Gemeinen Kiefer (Pinus sylvestris L.) zu untersuchen. Die Untersuchungsflächen befinden sich im Nordosten Deutschlands (Brandenburg). Im Untersuchungsgebiet Jerischke hat die Kiefer ein Alter von 78 Jahren und die Eiche ein Alter von 205 Jahren. Im Untersuchungsgebiet Weidmannsruh befindet sich die Kiefer im Alter 70 und die Eiche im Alter 108. In Abhängigkeit von der Entfernung zur Eiche werden folgende Effekte der Eiche nach Intensität und Qualität untersucht: - Effekte auf Mikroklima und Strahlung, - Effekte auf Humusmorphologie und bodenchemische Parameter und - Effekte auf Bodenvegetation und epigäische Fauna. Grundsätzlich sind die positiven Effekte der Eiche auf 10 bis 15 m vom Eichenstamm in den Kiefernbestand hinein begrenzt.
118

Radon: Vorkommen - Wirkung - Schutz

30 June 2022 (has links)
In der Broschüre erhalten Sie Informationen zu den Eigenschaften, sein Vorkommen und Empfehlungen für den Umgang mit Radon. Radon ist ein radioaktives Edelgas. Es ist natürlichen Ursprungs und wird hauptsächlich aus dem Boden in die Luft freigesetzt. Deshalb wird Radon vom Menschen eingeatmet und kann Lungenkrebs verursachen. Der Mensch kann sich vor den schädlichen Wirkungen durch geeignete Maßnahmen schützen. Redaktionsschluss: 26.03.2019, aktualisiert November 2021
119

Measurement of Pulse Train Instability in Ultrashort Pulse Characterization

Escoto, Esmerando 10 March 2020 (has links)
Die Messung ultrakurzer Laserpulse ist ein Eckpfeiler der ultraschnellen Laserphysik, da die Gültigkeit eines Experiments von der Glaubwürdigkeit seiner Messtechnik abhängt. Etablierte Puls-Charakterisierungstechniken beruhen jedoch häufig auf einer Mittelung über viele Pulse. Daher können sie falsche Informationen liefern, wenn die zeitliche Form von Puls zu Puls variiert. Diese Dissertation bietet Strategien zum sicheren Erfassen und Messen einer Degradierung der Puls-Kohärenz mit Hilfe von frequenzaufgelöstem optischem Gating (FROG), spektraler Phaseninterferometrie für die direkte Rekonstruktion elektrischer Felder (SPIDER) und Dispersionsscan (D-scan). Zu diesem Zweck werden Verbesserungen der Charakterisierungstechniken entwickelt. Die in dieser Arbeit entwickelten neuen Werkzeuge eröffnen nun einen Weg zur Untersuchung der Degradierung der Inter-Puls-Kohärenz, was eine zuverlässige Ultrakurzpulsmetrologie ermöglicht und das zuvor nicht nachweisbare Problem der Pulsfolgeninstabilität löst. / The measurement of ultrashort laser pulses is a cornerstone of ultrafast laser physics, as the validity of any experiment depends on the credibility of its measurement technique. However, established pulse characterization techniques often rely on averaging over many pulses. Therefore, they can return incorrect information if the temporal shape varies from pulse to pulse. This thesis provides strategies to safely detect and measure interpulse coherence degradation, using frequency-resolved optical gating (FROG), spectral phase interferometry for direct electric-field reconstruction (SPIDER), and dispersion scan (d-scan). To this end, improvements of the characterization techniques themselves are devised. The set of new tools developed in this thesis now opens up an avenue for the investigation of interpulse coherence degradation, leading to a more reliable ultrashort pulse metrology and solving the previously undetectable problem of pulse train instability.
120

Analysis of a coupled system of partial differential equations modeling the interaction between melt flow, global heat transfer and applied magnetic fields in crystal growth

Druet, Pierre-Etienne 23 February 2009 (has links)
Hauptthema der Dissertation ist die Analysis eines nichtlinearen, gekoppelten Systems partieller Differentialgleichungen (PDG), das in der Modellierung der Kristallzüchtung aus der Schmelze mit Magnetfeldern vorkommt. Die zu beschreibenden Phenomäne sind einerseits der im elektromagnetisch geheizten Schmelzofen erfolgende Wärmetransport (Wärmeleitung, -konvektion und -strahlung), und andererseits die Bewegung der Halbleiterschmelze unter dem Einfluss der thermischen Konvektion und der angewendeten elektromagnetischen Kräfte. Das Modell besteht aus den Navier-Stokeschen Gleichungen für eine inkompressible Newtonsche Flüssigkeit, aus der Wärmeleitungsgleichung und aus der elektrotechnischen Näherung des Maxwellschen Systems. Wir erörtern die schwache Formulierung dieses PDG Systems, und wir stellen ein Anfang-Randwertproblem auf, das die Komplexität der Anwendung widerspiegelt. Die Hauptfrage unserer Untersuchung ist die Wohlgestelltheit dieses Problems, sowohl im stationären als auch im zeitabhängigen Fall. Wir zeigen die Existenz schwacher Lösungen in geometrischen Situationen, in welchen unstetige Materialeigenschaften und nichtglatte Trennfläche auftreten dürfen, und für allgemeine Daten. In der Lösung zum zeitabhängigen Problem tritt ein Defektmaß auf, das ausser der Flüssigkeit im Rand der elektrisch leitenden Materialien konzentriert bleibt. Da eine globale Abschätzung der im Strahlungshohlraum ausgestrahlten Wärme auch fehlt, rührt ein Teil dieses Defektmaßes von der nichtlokalen Strahlung her. Die Eindeutigkeit der schwachen Lösung erhalten wir nur unter verstärkten Annahmen: die Kleinheit der gegebenen elektrischen Leistung im stationären Fall, und die Regularität der Lösung im zeitabhängigen Fall. Regularitätseigenschaften wie die Beschränktheit der Temperatur werden, wenn auch nur in vereinfachten Situationen, hergeleitet: glatte Materialtrennfläche und Temperaturunabhängige Koeffiziente im Fall einer stationären Analysis, und entkoppeltes, zeitharmonisches Maxwell für das transiente Problem. / The present PhD thesis is devoted to the analysis of a coupled system of nonlinear partial differential equations (PDE), that arises in the modeling of crystal growth from the melt in magnetic fields. The phenomena described by the model are mainly the heat-transfer processes (by conduction, convection and radiation) taking place in a high-temperatures furnace heated electromagnetically, and the motion of a semiconducting melted material subject to buoyancy and applied electromagnetic forces. The model consists of the Navier-Stokes equations for a newtonian incompressible liquid, coupled to the heat equation and the low-frequency approximation of Maxwell''s equations. We propose a mathematical setting for this PDE system, we derive its weak formulation, and we formulate an (initial) boundary value problem that in the mean reflects the complexity of the real-life application. The well-posedness of this (initial) boundary value problem is the mainmatter of the investigation. We prove the existence of weak solutions allowing for general geometrical situations (discontinuous coefficients, nonsmooth material interfaces) and data, the most important requirement being only that the injected electrical power remains finite. For the time-dependent problem, a defect measure appears in the solution, which apart from the fluid remains concentrated in the boundary of the electrical conductors. In the absence of a global estimate on the radiation emitted in the cavity, a part of the defect measure is due to the nonlocal radiation effects. The uniqueness of the weak solution is obtained only under reinforced assumptions: smallness of the input power in the stationary case, and regularity of the solution in the time-dependent case. Regularity properties, such as the boundedness of temperature are also derived, but only in simplified settings: smooth interfaces and temperature-independent coefficients in the case of a stationary analysis, and, additionally for the transient problem, decoupled time-harmonic Maxwell.

Page generated in 0.0593 seconds