• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analys av klimatskärmens lufttäthet i ett småhus

Hadodod, Melic, Ahlgren, Karl January 2007 (has links)
<p>Together with NCC and Sweco we measured the air-flow on a semi-detached house in Jönköping. When a pressure measurement is made, the house gets exposed to over- and under pressure. This is done in order to examine the houses climate shell. The climate shell of the semi-detached house we tested exceeded the required air thickness in BBR-2002, hence, measures have to be taken.</p><p>This report also displays the importance of building air thick houses and what consequences a non air-thick house can have for the ones residing the house. A discussion of different measures is on for the addressed problems with the flow-measurement and the alternative construction-solutions.</p><p>Furthermore we have described in this report of how to account for the performance of the air pressure, what kind of equipment we used and how we came up with the results. An ocular inspection was continually made in order for us to examine its gained results and thereby see why possible flaws arose.</p>
2

Analys av klimatskärmens lufttäthet i ett småhus

Hadodod, Melic, Ahlgren, Karl January 2007 (has links)
Together with NCC and Sweco we measured the air-flow on a semi-detached house in Jönköping. When a pressure measurement is made, the house gets exposed to over- and under pressure. This is done in order to examine the houses climate shell. The climate shell of the semi-detached house we tested exceeded the required air thickness in BBR-2002, hence, measures have to be taken. This report also displays the importance of building air thick houses and what consequences a non air-thick house can have for the ones residing the house. A discussion of different measures is on for the addressed problems with the flow-measurement and the alternative construction-solutions. Furthermore we have described in this report of how to account for the performance of the air pressure, what kind of equipment we used and how we came up with the results. An ocular inspection was continually made in order for us to examine its gained results and thereby see why possible flaws arose.
3

Optimering av täthetsprovning av ventiler / Optimization of leak testing of valves

Abrahamsson, Eric, Samuel, Palm January 2022 (has links)
Nordhydraulic är ett företag i Kramfors som tillverkar hydrauliska ventiler. Hydrauliska ventiller används inom en mängd olika områden för att styra hydrauliska maskiner. För att hydrauliska ventiler ska fungera korrekt måste dessa vara täta. På Nordhydraulic används en täthetsprovare av modell Nolek S9 N för att göra täthetstester. Täthetsprovaren fyller upp ventilerna med ett förbestämt tryck och mäter sedan flödet av luft in till ventilen som krävs för att bibehålla trycket. Idag har denna metod stora problem med falskt negativa resultat i monteringslinan, vilket innebär att täta ventiler ibland ger ett resultat som visar läckage och därför bildar en flaskhals i monteringen. Detta beror på att det finns många utrymmen i ventilen där luften har svårt att ta sig in. Syftet med det här arbetet var att ta fram ett bättre testprogram, alltså tidsinställningar av de olika parametrarna som används, till Nolek S9 N för att användas i täthetsprovningen för att minska stopp i monteringen. Framtagningen av detta program gjordes genom att göra mätningar med olika tidsinställningar samt anslutningsmetoder för att hitta de viktigaste parametrarna till programmet. Därefter gjordes mätningar på ventiler med monterings- och gjutfel för att se vilket flöde läckaget har vid dessa fel.  Arbetet resulterade i tre olika program för ventilen RS210 som vid tester i monteringen uppnådde godkäna resultat snabbare än det tidigare programmet som användes och med färre falskt negativa resultat. Slutsatsen är att de program som har tagits fram bör ge en förbättring av täthetsprovningen samt att den nuvarande gräns för godkända läckage kan höjas till 50 mm^3/s utan att missa de monteringsfel som kan uppstå. / Nordhydraulic is a company in Kramfors that manufactures hydraulic valves. Hydraulic valves are used in a variety of areas to control hydraulic machines. For hydraulic valves to function properly, they must be tight. At Nordhydraulic, a leak tester called Nolek S9 N is used to determine if valves are tight. The leak tester fills the valves with a predetermined pressure and then measures the flow of air into the valve required to maintain the pressure. Today, this method has major problems with false negative results in the assembly line, which means that tight valves may give a result that indicates leakage and thus can lead to a bottleneck in the assembly. This is because there are many spaces in the valve that are difficult to reach by the air. The purpose of this work was to develop a better program for the Nolek S9 N to be used in the leak test to reduce assembly stops. The development of this program is done by making measurements with different time settings as well as connection methods to find the most important parameters of the program. Then, measurements are made on valves assembly errors and casting errors to see what flow the leakage has at these errors. The work resulted in three different programs for the RS210 valve, which in tests in the assembly achieved approved results faster than the previous program and with fewer false negative results. The conclusion is that the developed program could provide an improvement of the leak test and that the current limit for approved leakage can be increased to 50 mm^3/s  without missing the assembly errors that may occur.
4

MÄTNING AV LUFTTÄTHET I FLERBOSTADSHUS : <em>Gällande krav, praktiskt genomförda mätningar samt en tillämpbar metod</em>

Sörensen, Ida January 2009 (has links)
<p>Stor förvirring råder kring hur lufttätheten ska mätas i flerbostadshus. De metoder som finns och de resultat som erhålls vid täthetsprovning av småhus är inte alltid applicerbara på flerbostadshus även om mätenheterna är de samma. Detta föranleder problemställningen för detta examensarbete:</p><p><em>Varför och hur kontrolleras lufttätheten i ett flerbostadshus på ett praktiskt tillämpbart sätt, som också gör det möjligt att jämföra resultat från olika objekt?</em></p><p>Metoderna som används för att undersöka detta är litteraturstudier och samtal med erfarna personer, samt demonstration av en mätmetod i fullskala. En diskussion med initiativtagarna till detta examensarbete leder fram till en rekommenderad metod och en mall för hur detta ska utföras.</p><p>Byggnadsskalets luft-, diffusions- och vindtätning har stor betydelse för en byggnads energianvändning, fuktsäkerhet, termiska komfort och hygien, luftkvalitet, ljudmiljö, spridning av brand samt spridning av luftföroreningar utifrån och in. Lufttätheten är en avgörande faktor både för konstruktionens beständighet och för en god innemiljö i moderna byggnader. Lufttäta hus är dessutom lönsamma i längden för de inblandade aktörerna. På lång sikt även för miljön. Studier som gjorts visar att en byggnads energiåtgång för uppvärmning minskar med nästan 30 % om lufttätheten (egentligen luftgenomsläppligheten) förbättras från 0,8 l/s·m<sup>2</sup> till 0,4 l/s·m<sup>2</sup>. En så stor minskning av energianvändningen kunde inte åstadkommas med andra energiförbättringsåtgärder som undersöktes.</p><p>I Boverkets Regelsamling för byggande, BBR 2008 har kravet på lufttäthet tagits bort till förmån för ett funktionskrav för energianvändningen, under vilken lufttätheten faller in. Regelsamlingens allmänna råd hänvisar till standarden, SS-EN 13829 för bestämning av luftläckage.</p><p>De metoder som idag finns att tillgå för att mäta lufttätheten hos byggnader är spårgasmetoden, täthetsprovning med provisorisk vägg, det egna ventilationssystemet, med mottryck i angränsande utrymmen samt med tryckdörr. Den sistnämnda metoden provades på flerbostadshus i Umeå med goda resultat.</p><p>Observera att resultatet för denna rapport är en mall för mätningsförfarandet och den rekommenderade metoden för att mäta lufttäthet inom NCC i Umeå. Den beskriver en praktiskt tillämpbar metod där resultatet går att jämföra mellan olika objekt. Även en intern mätstorhet som beskriver ytterväggens täthet är framtagen.</p><p>Mätstorheten och standardens relevans diskuteras. Ändringen i BBR från specificerade krav till funktionskrav anses vara kunskapsdrivande. Det förfarande som beskrivs i resultatet har bedömts vara det mest optimala under rådande förhållanden med den standard som finns. En förändring av standarden skulle kunna leda till en bättre metod som ger mer informativt resultat.</p> / <p>There is a great perplexity about how air permeability should be measured in multiple-unit dwellings. The methods available and the obtained results for determination of air permeability in single-dwelling houses are not applicable for multiple-unit dwellings, even if the derived quantities are the same. This causes the problem for this report:</p><p><em>Why and how should the air permeability be determined for a multiple-unit dwelling in a functional and applicable way, which also makes it possible to compare the obtained results from different dwelling units?</em></p><p>The methods used to explore solutions are literature studies, conversation with professionals and a full-scale demonstration of one of the methods. A discussion with the initiators of this report leads to the recommended method and a model for how it should be performed.</p><p>The air-, diffusion- and windtightness of the building envelope are of big importance to the building. The use of energy, moisture transfer, thermal comfort and hygiene, air quality, noise, spreading of fire and spreading of air pollutions are all affected by it. The air tightness is a crucial element for the durability of the building and to secure a good indoor environment. Air tight buildings are also cost-effective in the long run for the involved participants. They are also good for the environment. A study that have been made show that the energy-use for heating buildings will be reduced with almost 30 % if the air permeability improves from 0,8 l/s·m<sup>2</sup> to 0,4 l/s·m<sup>2</sup>. Such a big reduction of the energy use could not be accomplished with any other energy improvement-move that was investigated in the study.</p><p>The Swedish building regulations, Boverkets Regelsamling för byggande BBR, used to have a demand for the air tightness of buildings. It has been removed in favor of a demand of the function for the energy use, which also include the air tightness. The common advices in BBR refer to the standard, SS-EN 13829 for determination of air permeability.</p><p>The methods available for determination of air permeability in buildings are the tracer-gas method, determination with a temporary wall, the ventilation system, with corresponding pressure in adjacent spaces and determination with a Blower Door. The last method was demonstrated in multiple-unit dwellings in Umeå, Sweden, with good results.</p><p>Note that the result of this report is a methodology and how the method should be performed within buildings erected by NCC in Umeå. It describes a functional and applicable method where the results can be compared between different objects. An internal quantity which describes the air permeability of the external wall has been developed.</p><p>A discussion of the relevance if the derived quantity and the standard has been made. The change in BBR to demands of the function for the energy use has been considered to be a driving force for knowledge. The procedure described in the results has been considered to be the optimum procedure for existing conditions with the standard available. A change in the standard would lead to a better method which would give more informative results.</p>
5

MÄTNING AV LUFTTÄTHET I FLERBOSTADSHUS : Gällande krav, praktiskt genomförda mätningar samt en tillämpbar metod

Sörensen, Ida January 2009 (has links)
Stor förvirring råder kring hur lufttätheten ska mätas i flerbostadshus. De metoder som finns och de resultat som erhålls vid täthetsprovning av småhus är inte alltid applicerbara på flerbostadshus även om mätenheterna är de samma. Detta föranleder problemställningen för detta examensarbete: Varför och hur kontrolleras lufttätheten i ett flerbostadshus på ett praktiskt tillämpbart sätt, som också gör det möjligt att jämföra resultat från olika objekt? Metoderna som används för att undersöka detta är litteraturstudier och samtal med erfarna personer, samt demonstration av en mätmetod i fullskala. En diskussion med initiativtagarna till detta examensarbete leder fram till en rekommenderad metod och en mall för hur detta ska utföras. Byggnadsskalets luft-, diffusions- och vindtätning har stor betydelse för en byggnads energianvändning, fuktsäkerhet, termiska komfort och hygien, luftkvalitet, ljudmiljö, spridning av brand samt spridning av luftföroreningar utifrån och in. Lufttätheten är en avgörande faktor både för konstruktionens beständighet och för en god innemiljö i moderna byggnader. Lufttäta hus är dessutom lönsamma i längden för de inblandade aktörerna. På lång sikt även för miljön. Studier som gjorts visar att en byggnads energiåtgång för uppvärmning minskar med nästan 30 % om lufttätheten (egentligen luftgenomsläppligheten) förbättras från 0,8 l/s·m2 till 0,4 l/s·m2. En så stor minskning av energianvändningen kunde inte åstadkommas med andra energiförbättringsåtgärder som undersöktes. I Boverkets Regelsamling för byggande, BBR 2008 har kravet på lufttäthet tagits bort till förmån för ett funktionskrav för energianvändningen, under vilken lufttätheten faller in. Regelsamlingens allmänna råd hänvisar till standarden, SS-EN 13829 för bestämning av luftläckage. De metoder som idag finns att tillgå för att mäta lufttätheten hos byggnader är spårgasmetoden, täthetsprovning med provisorisk vägg, det egna ventilationssystemet, med mottryck i angränsande utrymmen samt med tryckdörr. Den sistnämnda metoden provades på flerbostadshus i Umeå med goda resultat. Observera att resultatet för denna rapport är en mall för mätningsförfarandet och den rekommenderade metoden för att mäta lufttäthet inom NCC i Umeå. Den beskriver en praktiskt tillämpbar metod där resultatet går att jämföra mellan olika objekt. Även en intern mätstorhet som beskriver ytterväggens täthet är framtagen. Mätstorheten och standardens relevans diskuteras. Ändringen i BBR från specificerade krav till funktionskrav anses vara kunskapsdrivande. Det förfarande som beskrivs i resultatet har bedömts vara det mest optimala under rådande förhållanden med den standard som finns. En förändring av standarden skulle kunna leda till en bättre metod som ger mer informativt resultat. / There is a great perplexity about how air permeability should be measured in multiple-unit dwellings. The methods available and the obtained results for determination of air permeability in single-dwelling houses are not applicable for multiple-unit dwellings, even if the derived quantities are the same. This causes the problem for this report: Why and how should the air permeability be determined for a multiple-unit dwelling in a functional and applicable way, which also makes it possible to compare the obtained results from different dwelling units? The methods used to explore solutions are literature studies, conversation with professionals and a full-scale demonstration of one of the methods. A discussion with the initiators of this report leads to the recommended method and a model for how it should be performed. The air-, diffusion- and windtightness of the building envelope are of big importance to the building. The use of energy, moisture transfer, thermal comfort and hygiene, air quality, noise, spreading of fire and spreading of air pollutions are all affected by it. The air tightness is a crucial element for the durability of the building and to secure a good indoor environment. Air tight buildings are also cost-effective in the long run for the involved participants. They are also good for the environment. A study that have been made show that the energy-use for heating buildings will be reduced with almost 30 % if the air permeability improves from 0,8 l/s·m2 to 0,4 l/s·m2. Such a big reduction of the energy use could not be accomplished with any other energy improvement-move that was investigated in the study. The Swedish building regulations, Boverkets Regelsamling för byggande BBR, used to have a demand for the air tightness of buildings. It has been removed in favor of a demand of the function for the energy use, which also include the air tightness. The common advices in BBR refer to the standard, SS-EN 13829 for determination of air permeability. The methods available for determination of air permeability in buildings are the tracer-gas method, determination with a temporary wall, the ventilation system, with corresponding pressure in adjacent spaces and determination with a Blower Door. The last method was demonstrated in multiple-unit dwellings in Umeå, Sweden, with good results. Note that the result of this report is a methodology and how the method should be performed within buildings erected by NCC in Umeå. It describes a functional and applicable method where the results can be compared between different objects. An internal quantity which describes the air permeability of the external wall has been developed. A discussion of the relevance if the derived quantity and the standard has been made. The change in BBR to demands of the function for the energy use has been considered to be a driving force for knowledge. The procedure described in the results has been considered to be the optimum procedure for existing conditions with the standard available. A change in the standard would lead to a better method which would give more informative results.

Page generated in 0.0617 seconds