• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 150
  • Tagged with
  • 150
  • 150
  • 150
  • 81
  • 70
  • 65
  • 38
  • 28
  • 26
  • 21
  • 21
  • 21
  • 20
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Densitovolumetria pulmonar nas doenças intersticiais

Martini, Simone de Leon January 2005 (has links)
As doenças pulmonares intersticiais difusas caracterizam-se pela presença de um distúrbio ventilatório restritivo cuja intensidade está associada ao grau de extensão do comprometimento intersticial e consequentemente ao estágio da doença. As provas de função pulmonar em conjunto com o grau de comprometimento intersticial na TCAR são os principais métodos de avaliação utilizados para determinar o estágio da doença, bem como para acompanhar sua progressão e a resposta terapêutica. A densitovolumetria pulmonar realizada através da TC Helicoidal consiste em uma técnica objetiva e mais precisa que permite calcular a proporção de volume de pulmão com densidade aumentada pelo acometimento por fibrose sobre o volume de pulmão com densidade normal, ou seja, sem acometimento significativo dos interstícios. Na literatura, sugere-se –870 UH como o limiar de separação ideal para quantificação de fibrose pulmonar por tomografia computadorizada, acima do qual o pulmão seria considerado como apresentando aumento de densidade pela presença de fibrose ou de atenuação em vidro-fosco. O presente estudo comparou o limiar fixo em –870UH com a utilização de um limiar subjetivo ou variável selecionado com o auxílio de máscara de densidades em 30 pacientes com comprovação histológica FPI em relação as provas de função pulmonar. A correlação dos resultados da densitovolumetria pulmonar utilizando o limiar fixo (-870 HU) com as provas de função pulmonar foram de r= 0,265 com o VEF1, r=-0,450 com a CVF, r=-0,705 com a CPT e r= -0,305 com a DCO. Em comparação, as correlações entre os resultados da densitovolumetria pulmonar estabelecidos com base na seleção subjetiva de um limiar subjetivo foram: r= –0,347 com o VEF1, r= - 0,534 com a CVF, r= -0,734 com a CPT e r= –0,413 com a DCO. Tanto as medidas objetivas como subjetivas da extensão da fibrose realizadas pela densitovolumetria apresentaram boa correlação com as medidas funcionais que expressam restrição. As correlações foram fracas, quando correlacionadas com medidas funcionais que não expressam a extensão da fibrose pulmonar. A densitovolumetria pode proporcionar uma técnica mais precisa que a simples análise subjetiva das imagens de tomografia computadorizada de alta resolução em pacientes com FPI, sendo assim mais efetiva na avaliação evolutiva de cada paciente. / Diffuse interstitial pulmonary diseases are characterized by restrictive lung disorders whose intensity is associated with the extent of interstitial involvement and, consequently, the stage of the disease. Pulmonary function tests and HRCT assessment of the degree of interstitial involvement are the primary methods to establish the stage of the disease, to follow up its progression, and to evaluate therapeutic response. Pulmonary densitovolumetry using helical CT is an objective and accurate technique to calculate the proportion of volume of lung with increased density due to fibrosis with relation to volume of lung with normal density, that is, without significant interstitial involvement. Studies in the literature suggest - 870 UH as the ideal segmentation threshold to assess pulmonary fibrosis using CT; above this value, increased density due to fibrosis or ground-glass opacity should be considered. In this study, the use of a -870 HU fixed threshold was compared with the use of a subjective or variable threshold selected with the aid of a density mask in 30 patients with a histologic diagnosis of IPF, and results were correlated with pulmonary function test results. Correlations between pulmonary densitovolumetry using the fixed threshold (-870 HU) and pulmonary function tests were r= 0.265 for FEV1, r=-0.450 for FVC, r=-0.705 for TLC and r= -0.305 for DLCO. When pulmonary densitovolumetry with selection of a subjective threshold was used, results were: r= –0.347 for FEV1, r= -0.534 for FVC, r= -0.734 for TLC and r= –0.413 for DLCO. Both objective and subjective measurements of the extent of fibrosis using densitovolumetry had a good correlation with results of functional tests that indicate restriction. Correlations were weak with functional measurements that do not indicate the extent of pulmonary fibrosis. Densitovolumetry may be a more accurate technique than the simple subjective analysis of high-resolution CT images in patients with IPF, and may be, therefore, more effective in the evaluation of disease progression.
112

Acurácia da escala de Borg modificada no exercício de crianças e adolescentes com fibrose cística

Hommerding, Patrícia Xavier January 2008 (has links)
Objetivos: Verificar a acurácia da escala de Borg modificada após o exercício na estimativa do comprometimento pulmonar medido pelo volume expiratório forçado no primeiro segundo (VEF1), em crianças e adolescentes com fibrose cística. Métodos: Estudo transversal e prospectivo em pacientes com FC (6 a 18 anos) em acompanhamento ambulatorial. Os parâmetros avaliados foram a sensação subjetiva da dispnéia através da escala de Borg modificada após o exercício correlacionando-a com a função pulmonar (espirometria) e secundariamente, com o teste de caminhada de 6 minutos (TC6) e com o estado nutricional pelo índice de massa corporal (IMC). Resultados: Foram incluídos 41 pacientes com a média de idade 11,1 ± 4,1 anos. A mediana da escala de Borg modificada após o TC6 foi 2(1-3). A média de percentual do previsto do volume expiratório forçado no primeiro segundo (VEF1%) foi de 96,6 ± 31,9%. Sessenta e um por cento dos pacientes apresentaram escore Z da distância percorrida (ZTC6) igual ou menor que -2. A escala de Borg modificada apresentou correlações fracas com as demais variáveis, quando toda a amostra foi avaliada. Houve correlação significativa e maior da escala com o VEF1 (r=-0,59; p=0,003) e com o ZTC6 (r=0,46; p=0,026), avaliando-se separadamente os pacientes com idade superior a 9 anos. Ao analisar os pacientes em diferentes níveis de corte de acordo com a idade pela curva ROC, obteve-se a partir do ponto de corte da escala de Borg modificada de 2,5 uma área de 0,80 proporcionando uma sensibilidade de 80% e especificidade de 77% na faixa etária superior a 9 anos para prever o VEF1% menor de 80%. Conclusão: A percepção subjetiva da dispnéia avaliada através da escala de Borg modificada apresenta acurácia em crianças com idade superior a 9 anos e adolescentes com fibrose cística. / Objectives: To evaluate the accuracy of the modified Borg scale to estimate lung impairment measured by forced expiratory volume in one second (FEV1) in children and adolescents with cystic fibrosis (CF). Methods: This cross-sectional prospective study was conducted with CF patients (6 to 18 years of age). Subjective perception of dyspnea, (modified Borg scale) before and after submaximal exercises, as well as its correlation with lung function (spirometry) and, secondarily, with the 6-minute walk test (6MWT) results and the nutritional status according to body mass index (BMI) were evaluated. Results: Forty-one patients aged 11.1 ± 4.1 years were included in the study. Median score in the modified Borg scale after 6MWT was 2 (1-3). Mean percent predicted of forced expiratory volume in one second (FEV1%) was 96.6 ± 31.9%. The z score of walked distance (Z6MWT) for 61% of the patients was equal to or lower than -2. The modified Borg scale correlated weakly with the other variables when all patients in the sample were analyzed. There was a significantly greater correlation of the scale with FEV1% (r=-0.59; P=0.003) and with 6MWTZ (r=0.46; P=0.026) when patients older than 9 years were evaluated separately. The ROC curve analysis revealed that a cut-off point of 2.5 in the modified Borg scale generated an area of 0.80, had a sensitivity of 80%, a specificity of 77% and accuracy of 0.78 to predict FEV1% lower than 80% in the group of patients older than 9 years. Conclusion: The modified Borg scale is accurate to assess the subjective perception of dyspnea of children older than 9 years and adolescents with cystic fibrosis.
113

Comparação das equações de valores de referência da função pulmonar mais utilizadas no Brasil: impacto no estadiamento da DPOC / Comparison of the equations of reference values ​​for lung function most used in Brazil: impact on staging of COPD

Pereira, Marcella Cristiane Silveira [UNIFESP] 30 June 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-30. Added 1 bitstream(s) on 2015-08-11T03:26:07Z : No. of bitstreams: 1 Publico-12636.pdf: 1313292 bytes, checksum: 9dc5695df095889d7733e20c113824b4 (MD5) / Objetivo: Comparar os valores absolutos da CVF e VEF1 de uma amostra randomizada da populacao de Sao Paulo com mais de 40 anos de idade com os valores previstos das equacoes mais utilizadas no Brasil. Comparar os valores em percentuais do previstos da CVF e VEF1 das equacoes selecionadas com os da equacao PLATINO. Avaliar a mudanca de estadio da DPOC ao se utilizar as diferentes equacoes de referencia. Material e Metodos: Estudo retrospectivo, com 178 pessoas normais da amostra de moradores da regiao metropolitana de Sao Paulo, com idade .40 anos, proveniente do estudo PLATINO. Para a comparacao da CVF e do VEF1, foram subtraidos dos valores previstos a partir de cada equacao os valores absolutos obtidos de cada individuo, considerando uma diferenca de ate 0,15L, como definida pela ATS. Tambem foi realizada a diferenca entre os valores do percentual do previsto da CVF e VEF1 das equacoes com os da equacao PLATINO, com diferenca . 3% (ATS). O diagnostico de DPOC foi definido pela relacao VEF1/CVF < 0,70 pos-broncodilatador e a comparacao do estadiamento foi realizada utilizando a variavel VEF1 em porcentagem do previsto de cada equacao, tendo como referencia o percentual previsto da equacao PLATINO. As equacoes foram aplicadas de acordo com os seus limites de idade e altura. Teste t-student, Qui-quadrado e coeficiente de correlacao intraclasse foram utilizados para avaliar o comportamento da CVF e VEF1 nas diferentes equacoes e os dados foram apresentados em media, desvio padrao, erro padrao e intervalo de confianca de 95%. Resultados: Observamos que as equacoes que apresentam menor diferenca entre o valor previsto e o valor absoluto para CVF e VEF1, em ambos os sexos, foram Roca et al. (n=151), Pereira et al. 2007 (n=176), Enright et al (n=43) e PLATINO (n=178). A equacao Knudson et al (n=177). subestimou os valores absolutos para CVF e VEF1. Na comparacao com a equacao PLATINO, em percentual do previsto para CVF e VEF1, a equacao que apresentou menor diferenca foi a NHANES III (n=172), exceto para CVF masculina, que apresentou grande variabilidade. Foram avaliados 152 pacientes com DPOC, estadiados pelo VEF1, segundo a equacao PLATINO, observando-se mudanca no estadiamento em 29,6% dos pacientes em relacao as equacoes, tendo a equacao Knudson et al. apresentado o maior numero de alteracoes. Conclusao: Existe uma grande variabilidade nos valores previstos entre as equacoes de referencia. As equacoes que apresentaram menor variabilidade e melhor coeficiente de correlacao intraclasse foram Roca et al., NHANES III caucasiano et al., Enright et al. e PLATINO, recomendando-se o seu uso para a populacao brasileira. Existe mudanca no estadio da DPOC quando diferentes equacoes sao aplicadas, sugerindo-se o uso de uma unica equacao durante o tratamento do mesmo paciente para evitar eventuais alteracoes no tratamento. / Objective: To compare the absolute values of FVC and FEV1 found in a random sample of a Brazilian population over 40 years of age with values of equations most used in Brazil. To compare the values in percentage of predicted of FVC and FEV1 of the selected equations with the PLATINO equation ones. To evaluate the change in COPD staying when using different reference equations. Material and Methods: We conducted a retrospective study from a representative sample of residents in the metropolitan region of Sao Paulo, aged .40 years, from the PLATINO study. For comparison of the FVC and FEV1, were subtracted from the predicted values of each equation the absolute values obtained from each individual, considering the equation inadequate wherever there was a difference of up to 0.15 L as defined by ATS. We also evaluated the difference between the values of FVC and VEF1 in percentage of predicted of the equations with the PLATINO equation, considering as a limit a difference .3% (ATS). The diagnosis of COPD was defined as FEV1/FVC <0.70 after bronchodilator, and the comparison of staging was performed using the FEB1 in percentage of predicted in each equation, with reference to the percentage expected from the PLATINO equation. T-student test, chi-squared and the intraclass correlation coefficient were used to evaluate the performance of FVC and FEV1 in different equations and data are presented as mean, standard deviation, standard error and confidence interval of 95%. Results: After evaluating 178 healthy subjects, we observed that the equations that show less difference between the predicted value and the absolute value for both FEV1 and FVC in both sexes were Roca et al., Pereira et al. 2006, Enright et al. and PLATINO. The Knudson et al. equation underestimated the absolute values for both FVC and FEV1. In comparison with PLATINO equation, the percentage of predicted for FVC and FEV1, the equation showing the lowest difference was NHANES III, except for FVC male, who showed a wide variability. We evaluated 152 patients with COPD, observing staging changes in 29.6% in relation to the difference equations, being Knudson et al. the equation that showed the greatest number of changes. Conclusion: There is a great variability among the reference equations. The equations showing less variability and better intraclass correlation coefficient were Roca et al., Caucasian NHANES III et al., Enright et al. and PLATINO, which are the ones that should be recommended to be used for the Brazilian population. There is a change in the COPD staging when different equations are applied, suggesting that the use of a single equation for the treatment of the patient would avoid possible alterations in treatment. / TEDE / BV UNIFESP: Teses e dissertações
114

Função pulmonar e teste de caminhada de seis minutos em indivíduos com doença falciforme

Ohara, Daniela Gonçalves 20 February 2014 (has links)
Made available in DSpace on 2016-06-02T20:19:22Z (GMT). No. of bitstreams: 1 5746.pdf: 1041939 bytes, checksum: b8d3091d836cd0fc85f86f1628bc4e8c (MD5) Previous issue date: 2014-02-20 / Financiadora de Estudos e Projetos / Background: Sickle Cell Disease (SCD) is characterized by a genetic mutation in beta hemoglobin chain, causing dysfunctions in the body, such as pulmonary function and functional capacity. Objective: To assessment the changes in pulmonary function and functional capacity in patients with sickle cell disease, as well as identify the relationship between these variables. Methods: Descriptive transversal study, exploratory and quantitative methodology, in which 21 subjects with sickle cell disease were evaluated (29±6 years), regarding sociodemographic, anthropometric, lung function (spirometry), respiratory (manovacuometer) and peripheral (Handgrip strength - HS) muscle strength and functional capacity (six-minute walk test - 6MWT). Proceeded to statistical analysis using the Shapiro-Wilk test, Paired t Student, Wilcoxon, Pearson and Spearman correlation (p<0.05). Results: It was observed changes in pulmonary function in 47.6% of subjects, 42.8% had a restrictive ventilatory pattern (RVP) and 4.8% had mixed ventilatory pattern. Maximal inspiratory pressure (MIP) presented predicted value below for women (obtained: 64±13cmH2O/ predicted: 93±2cmH2O) and maximum expiratory pressure (MEP), HS and distance walked during 6MWT had values below of predicted for men (obtained values: 103±27cmH2O; 39±7Kgf; 447±62m and predicted values: 143±5cmH2O; 45±1Kgf; 731±61m, respectively) and women (obtained values: 64±17cmH2O; 27±7Kgf; 405±71m and predicted values: 94±2cmH2O; 33±1Kgf; 683±30m, respectively). Positive correlations was observed of maximum voluntary ventilation (MVV) with MEP (r = 0.4; p=0.046) and body mass index (BMI) (r = 0.6; p=0.003); and HS with MIP (r = 0.7; p=0.001), MEP (r = 0.6; p=0.002), MVV (r = 0.5; p=0.015), distance walked in 6MWT (r = 0.4; p=0.038) and BMI (r=0.6; p=0.004). Conclusion: DF promoted changes in lung function and functional capacity, which predominated a RVP and reduced tolerance to physical exertion. In addition, these variables correlated with each other. / Contextualização: A Doença Falciforme (DF) caracteriza-se por mutação genética na cadeia beta da hemoglobina, gerando disfunções no organismo, como comprometimento da função pulmonar e da capacidade funcional. Objetivos: Avaliar as alterações da função pulmonar e da capacidade funcional de indivíduos com DF, assim como identificar a relação entre essas variáveis. Métodos: Estudo descritivo, transversal, de caráter exploratório e metodologia quantitativa, no qual foram avaliados 21 indivíduos com DF (29±6 anos), segundo aspectos sociodemográficos, antropométricos, função pulmonar (espirometria), força muscular respiratória (manovacuometria) e periférica (força de preensão palmar - FPP) e capacidade funcional (teste de caminhada de seis minutos - TC6). Procedeu-se à análise estatística com os testes Shapiro-Wilk, t de Student pareado, Wilcoxon, correlação de Pearson e Spearman (p<0,05). Resultados: Observou-se alteração da função pulmonar em 47,6% dos indivíduos, sendo 42,8% com padrão ventilatório restritivo (PVR) e 4,8% padrão ventilatório misto. A pressão inspiratória máxima (PImáx) apresentou valor abaixo do previsto somente para as mulheres (obtido: 64±13cmH2O/ previsto: 93±2cmH2O), enquanto a pressão expiratória máxima (PEmáx), a FPP e a distância percorrida no TC6 apresentaram valores abaixo do previsto tanto para homens (valores obtidos: 103±27cmH2O; 39±7Kgf; 447±62m e valores previstos: 143±5cmH2O; 45±1Kgf; 731±61m, respectivamente) quanto para as mulheres (valores obtidos: 64±17cmH2O; 27±7Kgf; 405±71m e valores previstos: 94±2cmH2O; 33±1Kgf; 683±30m, respectivamente). Observaram-se correlações positivas da ventilação voluntária máxima (VVM) com a PEmáx (r=0,4; p=0,046) e índice de massa corporal (IMC) (r=0,6; p=0,003); e da FPP com a PImáx (r=0,7; p=0,001), PEmáx (r=0,6; p=0,002), VVM (r=0,5; p=0,015), distância percorrida no TC6 (r=0,4; p=0,038) e IMC (r=0,6; p=0,004). Conclusão: A DF promoveu alterações na função pulmonar e na capacidade funcional, havendo predominância do PVR e redução da tolerância aos esforços físicos. Além disso, essas variáveis apresentaram correlação entre si.
115

Acurácia da escala de Borg modificada no exercício de crianças e adolescentes com fibrose cística

Hommerding, Patrícia Xavier January 2008 (has links)
Objetivos: Verificar a acurácia da escala de Borg modificada após o exercício na estimativa do comprometimento pulmonar medido pelo volume expiratório forçado no primeiro segundo (VEF1), em crianças e adolescentes com fibrose cística. Métodos: Estudo transversal e prospectivo em pacientes com FC (6 a 18 anos) em acompanhamento ambulatorial. Os parâmetros avaliados foram a sensação subjetiva da dispnéia através da escala de Borg modificada após o exercício correlacionando-a com a função pulmonar (espirometria) e secundariamente, com o teste de caminhada de 6 minutos (TC6) e com o estado nutricional pelo índice de massa corporal (IMC). Resultados: Foram incluídos 41 pacientes com a média de idade 11,1 ± 4,1 anos. A mediana da escala de Borg modificada após o TC6 foi 2(1-3). A média de percentual do previsto do volume expiratório forçado no primeiro segundo (VEF1%) foi de 96,6 ± 31,9%. Sessenta e um por cento dos pacientes apresentaram escore Z da distância percorrida (ZTC6) igual ou menor que -2. A escala de Borg modificada apresentou correlações fracas com as demais variáveis, quando toda a amostra foi avaliada. Houve correlação significativa e maior da escala com o VEF1 (r=-0,59; p=0,003) e com o ZTC6 (r=0,46; p=0,026), avaliando-se separadamente os pacientes com idade superior a 9 anos. Ao analisar os pacientes em diferentes níveis de corte de acordo com a idade pela curva ROC, obteve-se a partir do ponto de corte da escala de Borg modificada de 2,5 uma área de 0,80 proporcionando uma sensibilidade de 80% e especificidade de 77% na faixa etária superior a 9 anos para prever o VEF1% menor de 80%. Conclusão: A percepção subjetiva da dispnéia avaliada através da escala de Borg modificada apresenta acurácia em crianças com idade superior a 9 anos e adolescentes com fibrose cística. / Objectives: To evaluate the accuracy of the modified Borg scale to estimate lung impairment measured by forced expiratory volume in one second (FEV1) in children and adolescents with cystic fibrosis (CF). Methods: This cross-sectional prospective study was conducted with CF patients (6 to 18 years of age). Subjective perception of dyspnea, (modified Borg scale) before and after submaximal exercises, as well as its correlation with lung function (spirometry) and, secondarily, with the 6-minute walk test (6MWT) results and the nutritional status according to body mass index (BMI) were evaluated. Results: Forty-one patients aged 11.1 ± 4.1 years were included in the study. Median score in the modified Borg scale after 6MWT was 2 (1-3). Mean percent predicted of forced expiratory volume in one second (FEV1%) was 96.6 ± 31.9%. The z score of walked distance (Z6MWT) for 61% of the patients was equal to or lower than -2. The modified Borg scale correlated weakly with the other variables when all patients in the sample were analyzed. There was a significantly greater correlation of the scale with FEV1% (r=-0.59; P=0.003) and with 6MWTZ (r=0.46; P=0.026) when patients older than 9 years were evaluated separately. The ROC curve analysis revealed that a cut-off point of 2.5 in the modified Borg scale generated an area of 0.80, had a sensitivity of 80%, a specificity of 77% and accuracy of 0.78 to predict FEV1% lower than 80% in the group of patients older than 9 years. Conclusion: The modified Borg scale is accurate to assess the subjective perception of dyspnea of children older than 9 years and adolescents with cystic fibrosis.
116

Densitovolumetria pulmonar nas doenças intersticiais

Martini, Simone de Leon January 2005 (has links)
As doenças pulmonares intersticiais difusas caracterizam-se pela presença de um distúrbio ventilatório restritivo cuja intensidade está associada ao grau de extensão do comprometimento intersticial e consequentemente ao estágio da doença. As provas de função pulmonar em conjunto com o grau de comprometimento intersticial na TCAR são os principais métodos de avaliação utilizados para determinar o estágio da doença, bem como para acompanhar sua progressão e a resposta terapêutica. A densitovolumetria pulmonar realizada através da TC Helicoidal consiste em uma técnica objetiva e mais precisa que permite calcular a proporção de volume de pulmão com densidade aumentada pelo acometimento por fibrose sobre o volume de pulmão com densidade normal, ou seja, sem acometimento significativo dos interstícios. Na literatura, sugere-se –870 UH como o limiar de separação ideal para quantificação de fibrose pulmonar por tomografia computadorizada, acima do qual o pulmão seria considerado como apresentando aumento de densidade pela presença de fibrose ou de atenuação em vidro-fosco. O presente estudo comparou o limiar fixo em –870UH com a utilização de um limiar subjetivo ou variável selecionado com o auxílio de máscara de densidades em 30 pacientes com comprovação histológica FPI em relação as provas de função pulmonar. A correlação dos resultados da densitovolumetria pulmonar utilizando o limiar fixo (-870 HU) com as provas de função pulmonar foram de r= 0,265 com o VEF1, r=-0,450 com a CVF, r=-0,705 com a CPT e r= -0,305 com a DCO. Em comparação, as correlações entre os resultados da densitovolumetria pulmonar estabelecidos com base na seleção subjetiva de um limiar subjetivo foram: r= –0,347 com o VEF1, r= - 0,534 com a CVF, r= -0,734 com a CPT e r= –0,413 com a DCO. Tanto as medidas objetivas como subjetivas da extensão da fibrose realizadas pela densitovolumetria apresentaram boa correlação com as medidas funcionais que expressam restrição. As correlações foram fracas, quando correlacionadas com medidas funcionais que não expressam a extensão da fibrose pulmonar. A densitovolumetria pode proporcionar uma técnica mais precisa que a simples análise subjetiva das imagens de tomografia computadorizada de alta resolução em pacientes com FPI, sendo assim mais efetiva na avaliação evolutiva de cada paciente. / Diffuse interstitial pulmonary diseases are characterized by restrictive lung disorders whose intensity is associated with the extent of interstitial involvement and, consequently, the stage of the disease. Pulmonary function tests and HRCT assessment of the degree of interstitial involvement are the primary methods to establish the stage of the disease, to follow up its progression, and to evaluate therapeutic response. Pulmonary densitovolumetry using helical CT is an objective and accurate technique to calculate the proportion of volume of lung with increased density due to fibrosis with relation to volume of lung with normal density, that is, without significant interstitial involvement. Studies in the literature suggest - 870 UH as the ideal segmentation threshold to assess pulmonary fibrosis using CT; above this value, increased density due to fibrosis or ground-glass opacity should be considered. In this study, the use of a -870 HU fixed threshold was compared with the use of a subjective or variable threshold selected with the aid of a density mask in 30 patients with a histologic diagnosis of IPF, and results were correlated with pulmonary function test results. Correlations between pulmonary densitovolumetry using the fixed threshold (-870 HU) and pulmonary function tests were r= 0.265 for FEV1, r=-0.450 for FVC, r=-0.705 for TLC and r= -0.305 for DLCO. When pulmonary densitovolumetry with selection of a subjective threshold was used, results were: r= –0.347 for FEV1, r= -0.534 for FVC, r= -0.734 for TLC and r= –0.413 for DLCO. Both objective and subjective measurements of the extent of fibrosis using densitovolumetry had a good correlation with results of functional tests that indicate restriction. Correlations were weak with functional measurements that do not indicate the extent of pulmonary fibrosis. Densitovolumetry may be a more accurate technique than the simple subjective analysis of high-resolution CT images in patients with IPF, and may be, therefore, more effective in the evaluation of disease progression.
117

Densitovolumetria pulmonar nas doenças intersticiais

Martini, Simone de Leon January 2005 (has links)
As doenças pulmonares intersticiais difusas caracterizam-se pela presença de um distúrbio ventilatório restritivo cuja intensidade está associada ao grau de extensão do comprometimento intersticial e consequentemente ao estágio da doença. As provas de função pulmonar em conjunto com o grau de comprometimento intersticial na TCAR são os principais métodos de avaliação utilizados para determinar o estágio da doença, bem como para acompanhar sua progressão e a resposta terapêutica. A densitovolumetria pulmonar realizada através da TC Helicoidal consiste em uma técnica objetiva e mais precisa que permite calcular a proporção de volume de pulmão com densidade aumentada pelo acometimento por fibrose sobre o volume de pulmão com densidade normal, ou seja, sem acometimento significativo dos interstícios. Na literatura, sugere-se –870 UH como o limiar de separação ideal para quantificação de fibrose pulmonar por tomografia computadorizada, acima do qual o pulmão seria considerado como apresentando aumento de densidade pela presença de fibrose ou de atenuação em vidro-fosco. O presente estudo comparou o limiar fixo em –870UH com a utilização de um limiar subjetivo ou variável selecionado com o auxílio de máscara de densidades em 30 pacientes com comprovação histológica FPI em relação as provas de função pulmonar. A correlação dos resultados da densitovolumetria pulmonar utilizando o limiar fixo (-870 HU) com as provas de função pulmonar foram de r= 0,265 com o VEF1, r=-0,450 com a CVF, r=-0,705 com a CPT e r= -0,305 com a DCO. Em comparação, as correlações entre os resultados da densitovolumetria pulmonar estabelecidos com base na seleção subjetiva de um limiar subjetivo foram: r= –0,347 com o VEF1, r= - 0,534 com a CVF, r= -0,734 com a CPT e r= –0,413 com a DCO. Tanto as medidas objetivas como subjetivas da extensão da fibrose realizadas pela densitovolumetria apresentaram boa correlação com as medidas funcionais que expressam restrição. As correlações foram fracas, quando correlacionadas com medidas funcionais que não expressam a extensão da fibrose pulmonar. A densitovolumetria pode proporcionar uma técnica mais precisa que a simples análise subjetiva das imagens de tomografia computadorizada de alta resolução em pacientes com FPI, sendo assim mais efetiva na avaliação evolutiva de cada paciente. / Diffuse interstitial pulmonary diseases are characterized by restrictive lung disorders whose intensity is associated with the extent of interstitial involvement and, consequently, the stage of the disease. Pulmonary function tests and HRCT assessment of the degree of interstitial involvement are the primary methods to establish the stage of the disease, to follow up its progression, and to evaluate therapeutic response. Pulmonary densitovolumetry using helical CT is an objective and accurate technique to calculate the proportion of volume of lung with increased density due to fibrosis with relation to volume of lung with normal density, that is, without significant interstitial involvement. Studies in the literature suggest - 870 UH as the ideal segmentation threshold to assess pulmonary fibrosis using CT; above this value, increased density due to fibrosis or ground-glass opacity should be considered. In this study, the use of a -870 HU fixed threshold was compared with the use of a subjective or variable threshold selected with the aid of a density mask in 30 patients with a histologic diagnosis of IPF, and results were correlated with pulmonary function test results. Correlations between pulmonary densitovolumetry using the fixed threshold (-870 HU) and pulmonary function tests were r= 0.265 for FEV1, r=-0.450 for FVC, r=-0.705 for TLC and r= -0.305 for DLCO. When pulmonary densitovolumetry with selection of a subjective threshold was used, results were: r= –0.347 for FEV1, r= -0.534 for FVC, r= -0.734 for TLC and r= –0.413 for DLCO. Both objective and subjective measurements of the extent of fibrosis using densitovolumetry had a good correlation with results of functional tests that indicate restriction. Correlations were weak with functional measurements that do not indicate the extent of pulmonary fibrosis. Densitovolumetry may be a more accurate technique than the simple subjective analysis of high-resolution CT images in patients with IPF, and may be, therefore, more effective in the evaluation of disease progression.
118

Acurácia da escala de Borg modificada no exercício de crianças e adolescentes com fibrose cística

Hommerding, Patrícia Xavier January 2008 (has links)
Objetivos: Verificar a acurácia da escala de Borg modificada após o exercício na estimativa do comprometimento pulmonar medido pelo volume expiratório forçado no primeiro segundo (VEF1), em crianças e adolescentes com fibrose cística. Métodos: Estudo transversal e prospectivo em pacientes com FC (6 a 18 anos) em acompanhamento ambulatorial. Os parâmetros avaliados foram a sensação subjetiva da dispnéia através da escala de Borg modificada após o exercício correlacionando-a com a função pulmonar (espirometria) e secundariamente, com o teste de caminhada de 6 minutos (TC6) e com o estado nutricional pelo índice de massa corporal (IMC). Resultados: Foram incluídos 41 pacientes com a média de idade 11,1 ± 4,1 anos. A mediana da escala de Borg modificada após o TC6 foi 2(1-3). A média de percentual do previsto do volume expiratório forçado no primeiro segundo (VEF1%) foi de 96,6 ± 31,9%. Sessenta e um por cento dos pacientes apresentaram escore Z da distância percorrida (ZTC6) igual ou menor que -2. A escala de Borg modificada apresentou correlações fracas com as demais variáveis, quando toda a amostra foi avaliada. Houve correlação significativa e maior da escala com o VEF1 (r=-0,59; p=0,003) e com o ZTC6 (r=0,46; p=0,026), avaliando-se separadamente os pacientes com idade superior a 9 anos. Ao analisar os pacientes em diferentes níveis de corte de acordo com a idade pela curva ROC, obteve-se a partir do ponto de corte da escala de Borg modificada de 2,5 uma área de 0,80 proporcionando uma sensibilidade de 80% e especificidade de 77% na faixa etária superior a 9 anos para prever o VEF1% menor de 80%. Conclusão: A percepção subjetiva da dispnéia avaliada através da escala de Borg modificada apresenta acurácia em crianças com idade superior a 9 anos e adolescentes com fibrose cística. / Objectives: To evaluate the accuracy of the modified Borg scale to estimate lung impairment measured by forced expiratory volume in one second (FEV1) in children and adolescents with cystic fibrosis (CF). Methods: This cross-sectional prospective study was conducted with CF patients (6 to 18 years of age). Subjective perception of dyspnea, (modified Borg scale) before and after submaximal exercises, as well as its correlation with lung function (spirometry) and, secondarily, with the 6-minute walk test (6MWT) results and the nutritional status according to body mass index (BMI) were evaluated. Results: Forty-one patients aged 11.1 ± 4.1 years were included in the study. Median score in the modified Borg scale after 6MWT was 2 (1-3). Mean percent predicted of forced expiratory volume in one second (FEV1%) was 96.6 ± 31.9%. The z score of walked distance (Z6MWT) for 61% of the patients was equal to or lower than -2. The modified Borg scale correlated weakly with the other variables when all patients in the sample were analyzed. There was a significantly greater correlation of the scale with FEV1% (r=-0.59; P=0.003) and with 6MWTZ (r=0.46; P=0.026) when patients older than 9 years were evaluated separately. The ROC curve analysis revealed that a cut-off point of 2.5 in the modified Borg scale generated an area of 0.80, had a sensitivity of 80%, a specificity of 77% and accuracy of 0.78 to predict FEV1% lower than 80% in the group of patients older than 9 years. Conclusion: The modified Borg scale is accurate to assess the subjective perception of dyspnea of children older than 9 years and adolescents with cystic fibrosis.
119

Correlação entre perfil antropométrico, função respiratória e características do sono em crianças e jovens com síndrome de down

Santos, José Renato Campanelli Ferreira dos 05 February 2015 (has links)
Made available in DSpace on 2016-03-15T19:41:25Z (GMT). No. of bitstreams: 1 Alisson Rogerio Caetano de Siqueira.pdf: 1217726 bytes, checksum: 1361665d59b670b77eeaf91912135a0b (MD5) Previous issue date: 2015-02-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to characterize the anthropometric profile of a group of people with Down syndrome (DS), establishing correlations between body mass index variables, waist circumference, waist-hip ratio, body fat percentage established as from the bioelectrical impedance and skinfold measurements, with the peak expiratory flow and sleep characteristics. The study included 63 individuals with DS, of both sexes with age between 11 to 25, linked to DS care institutions. Data was collected: weight, height, waist circumference, hip circumference, body fat percentage by bioelectrical impedance and skinfold, peak expiratory flow and sleep characteristics from the Children Sleep Habits Questionnaire administered to the parents of the participants. Data were analyzed using Pearson's correlation test. All body composition variables showed marked tendency to excessive concentration of body fat with strong correlation. Waist-hip ratio presented high levels for risk of developing coronary heart disease and correlation with body composition variables for males only. The peak expiratory flow had similar results to other studies on DS with lower values compared to people with normal development but the correlation between body composition variables performed for males only. The characteristics of sleep showed results that suggest presence of sleep disorders with a high number of individuals classified above the cut-off point but the correlation with the body composition variables were observed in women only. It is believed that the lack of studies, specific reference tests and rates for the DS population is an important factor that can directly interfere in the data analysis. No composition index should be used in isolation and all results should be treated with discretion and careful manners in order that they are not over or underestimated. / O objetivo deste estudo foi caracterizar o perfil antropométrico de um grupo de pessoas com síndrome de Down (SD), estabelecendo correlações entre as variáveis de índice de massa corporal (IMC), circunferência de cintura (CC), relação cintura-quadril (RCQ), percentual de gordura (%G) estabelecida a partir da bioimpedância (BIA) e das medidas de dobras cutâneas (DC), com o pico de fluxo expiratório (PFE) e características do sono. Participaram do estudo 63 indivíduos com SD, de ambos os sexos com faixa etária compreendida entre 11 e 25 anos, vinculados a instituições de assistência à pessoa com SD. Foram coletados dados de peso, estatura, CC, circunferência de quadril, DC, %G por meio da bioimpedância, PFE e características do sono a partir do questionário Children Sleep Habits Questionnaire aplicado aos pais dos participantes. Os dados foram analisados por meio do teste de correlação de Pearson. Todas as variáveis de composição corporal apresentaram importante tendência de excessiva concentração de gordura assim como forte correlação entre si. A RCQ apresentou elevados índices para risco de desenvolvimento de doença coronariana e correlação com variáveis de composição corporal apenas para o sexo masculino. O PFE apresentou resultados semelhantes a outros estudos com SD, evidenciando valores inferiores se comparados à população com desenvolvimento típico, porém a correlação entre as variáveis de composição corporal apenas se apresentou para o sexo masculino. As características do sono mostraram resultados que sugerem a presença de distúrbios do sono com número elevado de indivíduos classificados acima da nota de corte, no entanto a correlação com as variáveis de composição corporal somente foram observadas no sexo feminino. Acredita-se que a escassez de estudos, testes e índices de referência específicos para a população com SD é um importante fator que pode interferir de maneira direta na análise do dados. Nenhum índice de composição corporal deve ser utilizado de maneira isolada e todos os resultados devem ser analisados com critério e de maneira cuidadosa afim de que não sejam super ou subestimados.
120

"Estudo comparativo de exercícios respiratórios em piscina aquecida para asmáticos graves e moderados: impacto de uma sessão" / A comparative study of breathing exercises in warm-water pool for moderate and severe asthma patients : a single session effects

Katia de Souza Pereira 29 September 2005 (has links)
Foi elaborado um programa de intervenção para pacientes asmáticos através da aplicação inédita de exercícios respiratórios em piscina coberta e aquecida, conduzidos por um fisioterapeuta, comparando-se o impacto de uma intervenção única do mesmo aplicado em solo. Participaram do estudo 40 pacientes adultos, asmáticos persistentes de moderados a graves, sem acompanhamento medicamentoso, fazendo uso apenas de ß2 agonista de curta duração. Avaliou-se a função pulmonar, a força muscular, a cirtometria, postura e escore de ansiedade. Verificou-se que a intervenção em água não foi prejudicial para os sujeitos, oferecendo alguns benefícios que superam aqueles encontrados em solo, como a mobilidade da caixa torácica, reeducação do padrão respiratório, melhora do desconforto respiratório e do estado de ansiedade / It was developed an original exercises program for asthmatic patients using breathing exercises in warm-water pool, conducted by a physiotherapist and subsequently compared with the same program performed in land in order to evaluate the effects of a single session respiratory exercise program. 40 adult patients, with moderated to severe asthma, without medical treatment, using only short action ß2 agonist were randomly allocated this study. It was evaluated the lung function, muscle strength, thoracic and abdominal circumference measurement, posture and anxiety. It was concluded that the water intervention is not harmful for the patients, offering some benefits which exceed those obtained in land, as thoracic mobility, reeducation of the respiratory pattern, improvement of the dyspnea and anxiety scores

Page generated in 0.0791 seconds