• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 25
  • 11
  • Tagged with
  • 114
  • 55
  • 44
  • 36
  • 35
  • 31
  • 27
  • 25
  • 23
  • 22
  • 16
  • 16
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Stratégies d’optimisation des protocoles en scanographie pédiatrique / Optimization Strategies on pediatric CT Protocol

Rani, Kaddour 14 December 2015 (has links)
Depuis le début des années soixante-dix, le nombre de scanners par hôpitaux n’a fait qu’augmenter et leur utilisation est de plus en plus fréquente. Même si cette technique permet de donner des informations cliniques précieuses, elle a un revers qui est l’exposition du patient à des rayonnements ionisants. La sensibilité des enfants aux rayonnements est plus grande que celle des adultes, les enfants ont une espérance de vie importante et ont donc plus de risques de développer des cancers dans le futur. Il y a donc nécessité de tenter de réduire la dose au patient. Cette thèse vise donc à développer des stratégies d’optimisation sur les protocoles cliniques en utilisant des méthodes de simulation et de modélisation permettant de comprendre l’influence des paramètres des protocoles sur les indicateurs de qualité d’image et sur la dose délivrée au patient. Ce travail se divise en quatre parties: La première partie porte sur la modélisation de l’influence des paramètres des protocoles scanographiques sur deux indicateurs de qualité d’image et un indicateur de dose en utilisant la méthodologie des plans d’expériences. La seconde partie traite du développement d’un Protocole Générique Optimisé (PGO) pour la région de l’abdomen. A partir des données des modèles développés, un PGO recalculé pour cinq morphologies de patients pédiatriques et pour quatre modèles de scanners a été réalisé. L’ensemble des résultats, ont permis le développement d’un outil d’aide à l’optimisation permettant à l’utilisateur de générer un protocole optimisé en fonction du modèle de scanner et de la morphologie du patient. / For the last 10-years, computed tomography (CT) procedures and their increased use have been a major source for concern in the scientific community. This concern has been the starting point for several studies aiming to optimize the dose while maintaining a diagnostic image quality. In addition, it is important to pay special attention to dose levels for children (age range considered to be from a newborn baby to a 16-y-old patient). Indeed, children are more sensitive to ionizing radiations, and they have a longer life expectancy. Optimizing the CT protocols is a very difficult process due to the complexity of the acquisition parameters, starting with the individual patient characteristics, taking into account the available CT device and the required diagnostic image quality. This PhD project is contributing to the advancement of knowledge by: (1) Developing a new approach that can minimize the number of testing CT scans examinations while developing a predictive mathematical model allowing radiologists to prospectively anticipate how changes in protocols will affect the image quality and the delivered dose for four models of CT scan. (2) Setting-up a Generic Optimized Protocol (based on the size of the phantom CATPAHN 600) for four models of CT scan. (3) Developing a methodology to adapt the GOP to five sizes of pediatric patient using Size Specific Dose Estimate calculation (SSDE). (4) Evaluating subjective and objective image quality between size-based optimised CT protocol and age-based CT protocols. (5) Developing a CT protocol optimization tool and a tutorial helping the radiologists in the process of optimization.
62

Développement et évaluation de nouveaux outils d'analyse géométrique 3D pour la prévention et le traitement des maladies aortiques / Development and evaluation of new 3D geometric analysis tools to prevent and treat aortic diseases

Craiem, Damian 13 October 2016 (has links)
Les nouvelles technologies d'imagerie basées sur la tomodensitométrie en coupe permettent l'évaluation de très haute qualité de la structure 3D de l'aorte thoracique. La reconstruction virtuelle et les modèles géométriques de l'aorte sont indispensables à l'exploitation des images dont le temps de traitement manuel reste cependant considérable et les outils numériques insuffisants ou inadaptés pour mesurer correctement sa morphologie. L'aorte n'est pas un simple tube de conduction du sang mais un organe de régulation de la pulsatilité des ondes de pression provoquées par l'éjection cardiaque. Ses désordres biomécaniques peuvent accélérer la formation de calcifications dans sa paroi et entrainer des risques de graves complications, comme les anévrismes et les dissections. La réparation aortique basée sur l'implantation d'endoprothèses est en pleine évolution et requiert des renseignements morphologiques précis pour en améliorer le taux de succès. Notre objectif a été d'étudier la géométrie tridimensionnelle de l'aorte en développant des algorithmes appropriés. Une plateforme informatique a été conçue et testée pour étudier trois pathologies de l'aorte: l'athérosclérose calcifiée, l'anévrisme et la dissection. L'hypothèse du travail a été que la géométrie spécifique des artères de chaque individu joue un rôle complémentaire à celui des facteurs de risque traditionnels dans le développement de ces pathologies. Notre premier travail a montré que trois facteurs résument 80% de la variabilité géométrique de l'aorte thoracique: le volume aortique, le déroulement et la symétrie de l'arche aortique, avec des taux de variabilité respectifs de 46%, 22% et 12%. Dans deux travaux suivants, nous avons montré que les calcifications de l'aorte thoracique se concentrent principalement dans la crosse et dans le segment descendant proximal, et que cette distribution était associée à la morphologie de l'aorte indépendamment de l'âge, du sexe, de la surface corporelle et des facteurs de risque traditionnels. Le quatrième travail a montré que le score de dépôt calcique dans toute l'aorte thoracique incluant la crosse était plus étroitement associé aux complications non-cardiaques, vasculaires périphériques et cérébrales, que le score traditionnel de calcium coronaire. Il faut noter que la crosse aortique n'est pas visualisée dans les études de routine de calcium coronaire sans injection. Le cinquième travail décrit un modèle déformable capable de segmenter la lumière aortique dans un contexte pathologique. Il a été appliqué pour étudier de façon automatisée la taille d'un anévrisme abdominal avant et après la pose d'une endoprothèse. Dans le dernier travail, la méthode précédente a été adaptée pour étudier la géométrie aortique des patients atteints de dissection comparativement à un groupe témoin de patients qui en étaient indemnes. Trois variables géométriques ont été identifiées dans le modèle de prédiction du risque de dissection: le diamètre de la crosse, la longueur de l'aorte thoracique et l'âge. En conclusion, nos résultats montrent que les maladies aortiques sont étroitement associées à la géométrie de l'aorte indépendamment des facteurs de risque traditionnels. Les algorithmes que nous avons développés ouvrent la voie à l'automatisation et à une réduction de la variabilité des mesures. / New imaging technologies, including those associated with multislice computed tomography, allow to evaluate the structure of the thoracic aorta in 3D with an impressive resolution. Aortic virtual reconstruction and geometric modeling are essential for imaging evaluation because manual measurements are time-consuming, and the available tools still need to be adapted to complex aortic morphologies. The aorta is more than a simple tubular conduit vessel for blood. It also regulates the pulsatile pressure waves that are injected into the arterial system by the left ventricle. The biomechanical disorders produced by these waves can accelerate the formation of calcium deposits within the arterial wall. Furthermore, they are thought to be responsible for severe aortic complications, including aneurysms and dissections. Endovascular aortic repair is a modern technique based on the implantation of an endograft to restore the normal blood flow. Precise morphological measurements are required to improve this technique, for both surgery planning and patient follow up. Our objective was to develop original algorithms to study the aortic geometry in 3D. A computing platform was designed and tested to analyze three main aortic pathologies: calcified atherosclerosis, aneurysms and dissections. The hypothesis of our study was that the individual arterial geometry of a subject plays a complementary role in the development of vascular pathologies beyond traditional risk factors. Our first work revealed that 80% of the total geometric variability in the thoracic aorta might be explained using 3 factors: the aortic volume, the aortic arc unfolding and its asymmetry. Variability percentages accounted for 46%, 22% and 12%, respectively. The next 2 works, showed that calcifications in the thoracic aorta were concentrated in the aortic arch and in the proximal descending segment. This spatial distribution was associated with aortic morphology, independently of age, sex, body surface area and traditional risk factors. Our fourth article revealed that calcium deposits in the entire thoracic aorta (including the aortic arch) was associated with non-cardiac events, beyond the standard coronary artery calcium score. It is noteworthy that the aortic arch region is systematically excluded from standard scans. Our fifth manuscript described a novel deformable model applied to the aortic segmentation under pathological contexts. It was used to estimate the size and shape of abdominal aneurysms before and after endograft implantation. In the last work, this method was adapted to study the geometry of the thoracic aorta of patients with an aortic dissection with respect to a control group. Three anatomic variables were identified for the risk prediction model: the aortic arch diameter, the thoracic aortic length and the age of the patient. In conclusion, our results show that aortic diseases are closely associated with aortic geometry, independently from traditional risk factors. The developed algorithms improved the automation of measurements and reduced the variability of the estimations.
63

Analyse de la relation entre l’exposition aux rayonnements ionisants lors d’examens de scanographie et la survenue de pathologie tumorale, au sein de la cohorte « Enfant Scanner » / Analysis of the Relation Between Exposure to Ionising Radiation from Computed Tomography Scans in Childhood and Cancer Incidence within the "Cohorte Enfant Scanner" Study

Journy, Neige 14 November 2014 (has links)
La scanographie est une technique d’imagerie médicale performante offrant des bénéfices considérables pour le diagnostic et le suivi médical des patients. Néanmoins, la question des effets adverses potentiels induits par l’exposition aux rayons-X se pose, tant au niveau individuel qu’en termes de santé publique du fait de la fréquence du recours à cette procédure. Des premières études épidémiologiques suggèrent une augmentation du risque de cancer associée à l’exposition à la scanographie durant l’enfance ou l’adolescence. Néanmoins, l’interprétation de ces résultats reste controversée et les connaissances sur le risque de cancer radio-induit à ce niveau d’exposition et pendant l’enfance demeurent limitées.En France, la cohorte « Enfant Scanner » est mise en place par l’IRSN pour étudier l’incidence de cancer dans une population de près de 110 000 enfants ayant reçu des examens par scanographie avant l’âge de 10 ans dans 21 centres hospitaliers universitaires. Cette étude participe au projet européen Epi-CT, coordonné par le Centre International de Recherche sur le Cancer, intégrant neuf cohortes nationales sur la base d’un protocole commun. A partir de la cohorte française, cette thèse s’intéresse à caractériser les expositions des enfants recevant des examens diagnostiques par scanographie et à fournir des éléments de quantification du risque de cancer associé.Une évaluation dosimétrique est réalisée à partir des protocoles radiologiques utilisés en pédiatrie entre 2000 et 2011 dans les services hospitaliers participant. Cette étude présente l’évolution des expositions au cours de la période ainsi que la variabilité des pratiques dans les services. Les résultats montrent l’existence d’une marge d’optimisation des protocoles utilisés pour limiter l’exposition des patients, en particulier pour des explorations de la tête qui sont les examens les plus fréquents en pédiatrie.Une évaluation du risque de cancer potentiellement induit par des actes de scanographie pédiatrique a été réalisée, sur la base d’estimations de risque obtenues pour d’autres contextes d’exposition aux rayonnements ionisants. Les résultats montrent que chaque examen pourrait être associé à un excès de risque de tumeur du système nerveux central (SNC), de cancer du sein, de la thyroïde ou de leucémies compris entre 0,01‰ et 5‰. Le risque de cancer serait jusqu’à 7 fois supérieur pour des patients âgés de 1 an par rapport à des enfants de 10 ans. Les incertitudes attachées à ces prédictions de risque ont été quantifiées par simulations.A partir du suivi d’incidence de la cohorte, la relation dose-réponse a été étudiée entre le risque de tumeurs du SNC, de leucémies et de lymphome, et les doses cumulées aux organes d’intérêt reçues lors d’examens par scanographie. Aucune augmentation significative de risque n’a été mise en évidence. En 2011, le suivi dans la cohorte – 4 ans en moyenne– était en effet très court. Les analyses ont néanmoins caractérisé l’impact de syndromes d’immunodéficiences et d’autres facteurs génétiques de prédisposition au cancer sur les estimations de risque, et mis en évidence l’importance de prendre en compte l’indication des examens dans ce type d’étude.Le suivi de la cohorte doit être poursuivi afin de fournir des estimations de risque plus robustes. L’extension de la durée de suivi de cette population ainsi que les résultats attendus à partir d’autres études, notamment dans le cadre du projet Epi-CT, devraient constituer, dans les 5 prochaines années, une avancée tout à fait significative sur la question des risques associés à la scanographie. A ce jour, les prédictions réalisées dans le cadre d’évaluations de risque demeurent incertaines, en particulier pour les tumeurs du SNC, mais constituent une aide pour orienter le recours à la scanographie. Des efforts d’optimisation des procédures radiologiques demeurent, par ailleurs, encore nécessaires pour réduire les doses délivrées en pédiatrie ainsi que les risques possiblement associés / Computed tomography (CT) is a powerful imaging technique that provides great benefits for diagnosis and medical management of patients. Nonetheless, the widespread use of this procedure raises many concerns about the potential adverse effects induced by X-rays exposure, both in clinical practice and in terms of public health. First epidemiological studies have suggested an increased risk of cancer associated with CT scan exposures in childhood or adolescence. The interpretation of these results is, however, controversial, and evidence about radiation-induced risks of cancer is still limited at this level of exposure and during childhood.In France, the "Enfant Scanner" cohort was set up by IRSN to study the incidence of cancer among more than 100,000 children who received CT scans before the age of 10 in 21 university hospitals. This study is part of the European Epi-CT project – coordinated by the International Agency for Research on Cancer – which includes nine national cohorts set up on the basis of a common protocol. The current thesis, based on the French cohort, focuses on characterizing the exposure of children receiving diagnostic CT scans and quantifying the risk of cancer associated with these exposures.Dosimetric assessment was performed from the radiological protocols used in paediatrics between 2000 and 2011 in the participating hospitals. This study presents the evolution of the exposures during the period and the variability of practices in the radiology departments. The results show that there is a leeway for optimizing the procedures and limiting the exposure of patients, especially for scans of the head that account for most of the examinations in paediatrics.From these exposure measurements, a quantitative assessment of cancer risk potentially induced by CT scans in paediatrics was performed – on the basis of estimates of risk in other contexts of ionizing radiation exposure. The results show that each CT scan could be associated with an excess risk of tumours of the central nervous system, breast cancer, thyroid cancer or leukaemia ranging from 0.01‰ to 5‰. Cancer risks may be up to 7 times higher for patients aged 1 year compared to 10 year olds. Uncertainties attached to these risk predictions were quantified by simulations.From the follow-up of cancer incidence in the cohort, the dose-response relation was studied between the risk of tumors of the central nervous system, leukaemia and lymphoma, and cumulative X-ray doses to the organs of interest from CT scans. No significant increased risk was observed. Indeed, in 2011, the duration of the follow-up, i.e. 4 years on average, was very short. The analyzes have nevertheless characterized the impact of (acquired or hereditary) immunodeficiencies and other genetic factors predisposing to cancer on the risk estimates, and highlighted the importance of considering the indication of examinations in studies on CT scans.The follow-up of the cohort should be extended to provide more robust risk estimates. Extension of this study as well as expected results from other cohorts, particularly within the Epi-CT project, would provide, in the next 5 years, significant progresses on the issue of the potential adverse effects of CT. To date, risk predictions from quantitative risk assessment are still uncertain, especially for cerebral tumours, but should help to guide the use of CT. In addition, efforts for optimizing the radiological procedures are still needed to reduce the doses delivered in paediatrics and the potential associated risks.
64

Predictive values of neurological examination, otoscopic examination and brainstem auditory evoked response (BAER) in calves with otisis media-interna

Finnen, Andrea 04 1900 (has links)
Présentement, le diagnostic d’otite moyenne-interne chez le veau est basé sur la présence de signes cliniques appropriés ainsi que les tests diagnostiques tels que la radiographie et la tomodensitométrie. L’objectif de cette étude prospective était d’évaluer les valeurs prédictives de l’examen neurologique, l’examen otoscopique et le test des potentiels auditifs évoqués (PAE) dans le diagnostic d’otite moyenne-interne chez le veau, en utilisant la tomodensitométrie comme test standard. Le deuxième objectif était de définir les valeurs de référence pour le PAE chez le veau normal et d’en décrire les anomalies chez des veaux atteints d’otite moyenne-interne. Dix-sept veaux de race Holstein entre 5-7 semaines d’âge ont été inclus. Tous les veaux ont eu un examen neurologique, un examen otoscopique et une évaluation des PAEs. Les veaux ont été tranquillisés avec de la xylazine intraveineuse (0,05-0,15mg/kg) pour la tomodensitométrie des bulles tympaniques afin d’évaluer pour la présence d’otite moyenne-interne. Selon les résultats de la tomodensitométrie, 11 des 17 veaux étaient atteints avec otite moyenne, 4 de façon unilatérale et 7 bilatéralement. Cinq ondes ont été identifiées de façon constante sur les tracés des PAEs des 6 veaux normaux. Les valeurs positives prédictives pour le PAE, l’examen neurologique et l’examen otoscopique étaient 94,7%, 91,7% et 66,7% respectivement. D’un point de vue clinique, le test le plus fiable dans le diagnostic d’otite moyenne-interne chez le veau est le PAE. Les anomalies ont été observées au PAE avant le développement des signes neurologiques chez certains veaux. / Currently, the antemortem diagnosis of otitis media-interna is based upon the presence of appropriate clinical signs and adjunctive diagnostic imaging including radiography and computed tomography. The purpose of this prospective study was to evaluate predictive values of neurological examination, otoscopic examination and BAER in calves for the diagnosis of otitis media-interna using computed tomography as the gold standard. The second objective was to define BAER reference values in normal calves and to describe BAER abnormalities in calves affected with otitis media-interna. Seventeen Holstein calves between 5 and 7 weeks of age were included. All calves had a neurological examination, otoscopic examination and BAER. Calves were sedated with intravenous xylazine (0.05-0.15 mg/kg [0.02-0.07 mg/lb]) for computed tomography of the tympanic bullae to evaluate for the presence of otitis media-interna. Based upon computed tomographic results, 11 of 17 calves were affected with otitis media, 4 unilaterally and 7 bilaterally. Five waveforms were consistently identified on BAER traces from 6 normal calves. The positive predictive value of BAER, neurological examination and otoscopic examination were 94.7%, 91.7% and 66.7% respectively. Clinically, the most reliable non-invasive diagnostic test to diagnose otitis media-interna in the calf is the BAER. Abnormalities were observed on BAER before the development of neurological deficits in approximately 40% of calves allowing earlier diagnosis.
65

Conception des circuits de polarisation des détecteurs et de maintien de la tension de base du LabPET II

Panier, Sylvain January 2014 (has links)
Par le passé, la collaboration entre le Centre d'Imagerie Médicale de Sherbrooke (CIMS) et le Groupe de Recherche en Appareillage Médicale de Sherbrooke (GRAMS) a permis de développer le scanner LabPET. Celui-ci fut le premier scanner de Tomographie d'Émission par Positrons (TEP) commercial utilisant des photodiodes à effet avalanche (PDA) comme détecteur. Depuis, cette collaboration a permis de faire évoluer le scanner afin d'améliorer cette modalité d'imagerie et d'y ajouter la tomodensitométrie (TDM). Les attentes pour la prochaine génération du scanner sont donc grandes. Cette nouvelle génération du scanner, le LabPET II, verra les deux modalités nativement intégrées et elles utiliseront la même chaine de détection. Ce scanner se verra doté de nouveaux détecteurs organisés en matrices de 64 cristaux de 1,1 par 1,1 mm². Cette nouvelle matrice, associée à ses deux matrices de 32 PDA, a prouvé sa capacité à fournir une résolution spatiale inférieure au millimètre. L'utilisation de ce nouveau module de détection pourra donc permettre au LabPET II d'être le premier scanner bimodal (TEP/TDM) commercial atteignant une résolution submillimétrique. Ce scanner permettra de s'approcher un peu plus de la résolution spatiale ultime en TEP tout en permettant une bonne localisation anatomique grâce à l'ajout d'une imagerie TDM rudimentaire. Pour atteindre ces objectifs, une intégration complète de l'électronique frontale a été nécessaire. Dans les versions précédentes, seuls les préamplificateurs de charge et les filtres de mise en forme étaient intégrés; dans cette nouvelle version, toute l'électronique analogique ainsi que la numérisation et les liens de communications devront être intégrés. Pour ce faire, la technique de temps de survol au-dessus d'un seuil (ou ToT pour «Time-over-Threshold») a été préférée à la solution utilisée par le LabPET I qui nécessitait un convertisseur analogique-numérique par canal. La contrepartie de cette solution est l'obligation de maintenir la tension de base à une valeur fixe et commune à tous les canaux. Le circuit de polarisation des PDA a aussi dû être intégré dans l'ASIC, car il occupait énormément de place sur la carte d'électronique frontale du LabPET 1. Dans ce mémoire seront décrits la conception, l'intégration et les tests de ces deux circuits du système. Ils ont démontré leur efficacité tout en n'occupant que très peu de place dans le circuit intégré spécialisé (ASIC) du «module de détection». Au vu des sources bibliographiques recensées, le module de détection du LabPET II devrait être l'un de ceux ayant la plus forte densité de canaux (environ 45 par centimètre carré) et le seul combinant électronique analogique faible bruit, numérique et haute tension (~450 V). La réalisation de cette nouvelle génération devrait permettre au partenariat CIMS/GRAMS de réaffirmer leur position de leader dans le domaine en améliorant les outils d'imagerie à la disposition des chercheurs en médecine préclinique.
66

Fracture partielle de la tête radiale : développement et validation d’un outil radiologique et impact sur la fonction du coude

Couture, Anne 04 1900 (has links)
No description available.
67

Amélioration du calcul de la masse osseuse par micro-tomodensitométrie X : prise en compte des phénomènes physiques / Bone mass measurement improvement in micro-CT taking into account the physical phenomena

Koubar, Khodor 22 November 2013 (has links)
Suite à l'allongement de la survie des patients atteints de la mucoviscidose (CF), des études ont montré la présence d'une perte osseuse chez les patients CF. Dans ce travail de thèse, une étude de l'évolution de la densité minérale osseuse chez des souris atteintes de mucoviscidose a été effectuée en utilisant un système de micro-tomodensitométrie X. Afin d'améliorer les précisions des mesure, deux méthodes de correction de deux phénomènes physiques ont été appliquées. La première méthode est une correction du durcissement de faisceau X et basée sur une segmentation de l'objet reconstruit après une première reconstruction et en utilisant des courbes d'atténuations précalculées. La deuxième méthode est une méthode de correction de la diffusion des rayons dans l'animal basée sur l'estimation des projections des diffusés en utilisant des noyaux de diffusion précalculées. Des améliorations au niveau de la qualité de l'image et les mesures de densité osseuses ont été obtenues. / Due to the increased survival of the patients with cystic fibrosis (CF), studies showed the presence of osteoporosis in CF patients. In this work, a follow-up study of the bone mineral density (BMD) formice with CF is done using a micro-CT system. In order to perform accurately the measurements, weapplied two correction methods aiming to reduce artifacts in CT images. The first correction method is abeam hardening correction technique based on a post-reconstruction procedure and usingpre-calculated linearization curves. The second correction method is a hybrid elimination approach of scatter radiations from acquisition projections and based on the use of pre-calculated scatter kernels,simulated analytically. Improvements have been shown concerning image quality (contrast, artifactsreduction) and BMD measurements.
68

Incertitudes et mouvement dans le traitement des tumeurs pulmonaires : De la radiothérapie à l’hadronthérapie / Uncertainties and motion management in lung radiotherapy : From photons to ions

Bouilhol, Gauthier 26 November 2013 (has links)
Cette thèse porte sur la prise en compte des incertitudes et du mouvement dans le traitement des tumeurs pulmonaires en radiothérapie, que ce soit par photons, par protons ou par ions légers (hadronthérapie). L’accent est mis sur les méthodes de prise en compte du mouvement dites "passives". Ces méthodes, ne nécessitant pas d’asservissement respiratoire pour la délivrance de la dose, sont moins lourdes à mettre en place, et limitent l’introduction de nouvelles sources d’incertitudes. Des contributions cliniques et méthodologiques sont proposées. Tout d’abord, l’imagerie tomodensitométrique (TDM) pour la planification des traitements doit faire l’objet d’une attention particulière dans le cas de tumeurs soumises aux mouvements respiratoires. Nous avons évalué l’influence de la présence d’artéfacts de mouvements dans les images TDM sur la qualité de la planification. Nous avons également proposé des méthodologies et des recommandations pour l’optimisation des paramètres d’acquisition ainsi qu’un algorithme original de détection automatique des artéfacts dans les images TDM 4D. L’une des principales sources d’incertitudes lors de la planification de traitements en radiothérapie concerne la délinéation des volumes cibles. Nous avons évalué la variabilité inter-observateur de délinéation du volume cible macroscopique (GTV) et du volume cible interne (ITV) via une méthode originale permettant de l’intégrer dans le calcul des marges de sécurité. La réduction des incertitudes dues au mouvement respiratoire peut être réalisée en associant au système de contention une compression abdominale afin de limiter l’amplitude du mouvement respiratoire. Nous avons proposé une étude visant à évaluer l’impact de l’utilisation d’un tel système en fonction de la localisation dans le poumon. En radiothérapie par photons, une stratégie appelée mid-position consiste à irradier la tumeur dans sa position moyenne pondérée dans le temps et permet de réduire les marges par rapport à une stratégie ITV tout en conservant une couverture dosimétrique correcte. Une partie du travail de la thèse a consisté à participer à l’élaboration d’une étude clinique visant à comparer les deux stratégies, ITV et mid-position. Dans la plupart des cas, le mouvement respiratoire a une distribution de probabilité non-gaussienne et asymétrique, pouvant invalider la recette de calcul de marges de van Herk pour des mouvements tumoraux fortement asymétriques et de grande amplitude. Nous avons proposé un modèle numérique afin de prendre en compte cette asymétrie. Enfin, la prise en compte du mouvement respiratoire en hadronthérapie par des marges de sécurité doit faire l’objet de considérations spécifiques, en particulier en raison de la sensibilité du dépôt de dose aux variations de densité sur la trajectoire du faisceau. Dans une dernière partie, la définition des marges de sécurité pour prendre en compte le mouvement respiratoire de manière optimale est discutée. / This PhD thesis focuses on the uncertainties and motion management in lung radiation therapy and particle therapy. Passive motion management techniques are considered. They consist in delivering the dose without any respiratory beam monitoring which may be difficult to set up or may introduce additional uncertainties. Clinical and methodological contributions about different treatment steps are proposed. First of all, computed tomography (CT) images for treatment planning must be carefully acquired in the presence of respiration-induced tumor motion. We assessed the impact of motion artifacts on the quality of treatment planning. We also proposed methodologies and recommendations about the optimization of 4D-CT acquisition parameters and an original method for automated motion artifact detection in 4D-CT images. Target delineation introduces one of the main source of uncertainties during radiation therapy treatment planning. We quantified inter-observer variations in the delineation of the gross tumor volume (GTV) and the internal target volume (ITV) using an original method in order to incorporate them in margin calculation. Reduction of motion uncertainties can be achieved by combining an abdominal pressure device with the immobilization system to reduce the amplitude of respiratory motion. We proposed a study to evaluate the usefulness of such a device according to the tumor location within the lung. Delivering the dose to the ITV implies an important exposure of healthy tissues along the tumor trajectory. An alternative strategy consists in irradiating the tumor in its time-averaged mean position, the mid-position. Margins are reduced compared with an ITV-based strategy while maintaining a correct tumor coverage. One part of the work consisted in participating in the implementation of a clinical trial in photon radiation therapy to compare the two strategies, ITV and mid-position. In the margin recipe proposed by van Herk, a Gaussian distribution of all combined errors is assumed. In most cases, respiratory motion has an asymmetric non-Gaussian distribution and the assumption may not be valid for strongly asymmetric tumor motions with a large amplitude. We proposed a numerical population-based model to incorporate asymmetry and non-Gaussianity of respiratory motion in margin calculation. Finally, when taking respiratory motion into account in particle therapy with safety margins, one must consider various parameters, particularly the dose deposit sensitivity to density variations. The last part is dedicated to a discussion on the defining of safety margins in order to optimally take into account respiratory motion.
69

Imagerie de l'appendicite aiguë chez l'adulte

Keyzer, Caroline 23 November 2009 (has links)
L’appendicite aiguë est la pathologie abdominale aiguë courante et la plus fréquente parmi celles qui nécessitent une intervention chirurgicale rapide. L’imagerie occupe une place croissante dans son diagnostic parce qu’elle tente d’éviter simultanément les appendicectomies inutiles et les perforations appendiculaires compliquées de péritonite tout en recherchant des pathologies alternatives. Si plusieurs techniques d’imagerie sont disponibles – dont la radiographie sans préparation de l’abdomen (dont la performance est faible) et l’imagerie par résonance magnétique (peu disponible, en particulier en urgence) – l’ultrasonographie (US) et la tomodensitométrie (TDM) occupent des positions centrales. Nos études ont investigué la performance de ces dernières, en considérant notamment la réduction de la dose d’irradiation et le recours aux contrastes artificiels. En effet, l’irradiation liée à l’usage de la TDM est à considérer puisque les patients souffrant d’appendicite aiguë sont jeunes (en moyenne 30 ans) tout comme le recours aux contrastes associé à des coûts, de l’inconfort et des risques. Enfin, la performance de ces techniques étant susceptibles d’être influencée par la corpulence des patients et leur quantité de graisse intra-abdominale, l’influence de ces paramètres sur la performance a été évaluée.<p><p>A travers quatre études, nous avons montré que l’US et la TDM sans contraste IV ou entérique ont des performances similaires quant au diagnostic d’appendicite aiguë et de pathologies alternatives, indépendamment de l’expérience du radiologue et de la corpulence du patient. Néanmoins, les examens non concluants (sans diagnostic d’appendicite aiguë ni de pathologie alternative mais où l’appendice n’est pas vu) sont plus fréquents en US qu’en TDM. L’appendice normal, dont la visualisation permet d’exclure le diagnostic d’appendicite aiguë, est plus fréquemment visible en TDM qu’en US, mais en TDM la reproductibilité quant à considérer la même structure comme étant l’appendice dépend du lecteur. L’injection IV de contraste iodé n’augmente pas la proportion d’appendices détectés mais la reproductibilité d’un lecteur particulier. Aucune caractéristique du sujet ni de son appendice, y compris son environnement abdominal, ne permet de prédire cette reproductibilité. La performance de la TDM est constante quelle que soit la dose d’irradiation ou le recours au contraste IV et/ou entérique, indépendamment de la corpulence du patient. La hiérarchie de l’information apportée par les signes évocateurs d’appendicite aiguë n’est pas influencée par la dose; l’infiltration de la graisse péri-appendiculaire et le diamètre appendiculaire en étant les signes les plus prédictifs, malgré le moindre rapport signal/bruit de l’image générée à faible dose. La fréquence de visualisation de l’appendice est aussi indépendante de cette dose. L’exactitude du diagnostic dépend principalement du lecteur mais pas du contraste – quelle qu’en soit la voie d’administration (orale ou IV) – ni de la dose d’irradiation. Le genre du patient influence cependant cette exactitude, le diagnostic étant plus fréquemment correct chez l’homme que chez la femme, en particulier dans les pathologies alternatives.<p><p>En conclusion, comme les techniques US et TDM que nous avons investiguées ont des performances équivalentes, les risques associés à l’irradiation et au contraste doivent intervenir dans leur choix. L’US, utilisée en première intention, devrait être complétée par la TDM si son résultat n’est pas concluant. Dans ce cas, la TDM devrait être réalisée, toujours à basse dose d’irradiation, d’abord sans puis, si nécessaire, avec contraste IV et/ou oral.<p> / Doctorat en Sciences médicales / info:eu-repo/semantics/nonPublished
70

Formulation de nano-particules iodées comme agents de contraste a longue rémanence vasculaire pour tomodensitométrie / Formulation of iodinated nano-particles as micro-CT blood pool contrast media

Hallouard, François 12 December 2012 (has links)
L’objectif de cette thèse est de réaliser un agent de contraste vasculaire pour tomodensitométrie utilisable en préclinique. En collaboration avec le laboratoire de biogalénique de Strasbourg, ce travail a permis d’obtenir des nano-émulsions iodées produites par diffusion spontanée de surfactif et des nanoparticules iodées produites par ”émulsion - diffusion de solvant”, comme agent de contraste vasculaire. Ces émulsions et particules polymériques présentent en effet, un temps de rémanence vasculaire de plusieurs heures, un pouvoir contrastant suffisant pour un usage en tomodensitométrie (compris entre 170 et 400 HU), la possibilité de les administrer par intraveineuse et une stabilité de plusieurs mois. Les nano-émulsions, notamment celles produites à partir de Lipiodol®, sont les plus prometteuses comme agents de contraste vasculaire de par leur forte radiopacité (475 ± 30 HU) et leur rémanence vasculaire (T1/2 of 4.1 ± 1.10 h). Les nanoparticules iodées à base de PCL présentent un pouvoir contrastant inférieur (168 ± 13 HU) mais elles sont connus pour leur capacité à modifier la libération du principe actif encapsulé. De ce fait même si les agents de contraste de nature lipidique ou ceux inorganiques sont plus performant, elles restent intéressantes pour une visualisation rapide de la distribution du principe actif dans l’organisme. Cette thèse par ailleurs, apporte plusieurs éléments pour la compréhension de la formulation des nano-émulsions obtenues par diffusion spontanée de surfactif et celle des nanoparticules produites par ”émulsion - diffusion de solvant”. Concernant les nano-émulsions, l’influence de l’iodation des huiles et du surfactif a été étudiée autant sur le plan pharmacotechnique que ceux toxicologique et pharmacocinétique. Concernant les nanoparticules à base de PCL, nous avons montré que l’impact du type d’huile et de l’iodation, des polymères PCL et PCL-mPEG et de diverses méthodes de concentration sur la formulation / The aim of this thesis is to formulate a blood pool contrast agent for preclinical X-ray imaging application. In collaboration with the galenic laboratory of Strasbourg, this work has allowed to obtain iodinated nano-emulsions produced by spontaneous diffusion of surfactant and nano-particles produced by iodine ”emulsion - solvent diffusion” as blood pool contrast agent. These emulsions and polymer particles present indeed a vascular persistence of several hours, a sufficient contrast to be use in computed tomography (between 170 and 400 HU), the ability to be administered intravenous and stability of several months. Nano-emulsions, including those produced from Lipiodol®, are the most promising as blood pool contrast media by their high radiopacity (475 ± 30 HU) and vascular persistence (T1/2 of 4.1 ± 1.10 h). Iodinated nano-particles of PCL have a lower X-ray attenuation (168 ± 13 HU), but they are known for their control release of the encapsulated substances. Therefore even if inorganic or lipidic contrast agents show a better contrast, they remain attractive for rapid visualization of the co-encapsulated substance distribution in the body. This thesis also introduced several features for understanding the formulation of nano-emulsions obtained by spontaneous diffusion of surfactant and the nano-particles produced by ”emulsion - solvent diffusion.”

Page generated in 0.071 seconds