• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 6
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 143
  • 110
  • 109
  • 85
  • 85
  • 78
  • 76
  • 57
  • 52
  • 50
  • 45
  • 42
  • 26
  • 24
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Estudo comparativo da eficácia da fonoforese, do ultra-som terapêutico e da aplicação tópica de hidrocortisona no tratamento do tendão de rato em processo de reparo tecidual / Comparative study of the efficacy of phonophoresis, therapeutic ultrasound and topic hydrocortisone application in the treatment of rat tendon in tissue repair process

Paulo Umeno Koeke 19 December 2003 (has links)
A proposta deste estudo foi comparar a eficácia de tratamento da aplicação tópica de hidrocortisona, do ultra-som terapêutico e da fonoforese no processo de reparo do tendão de Aquiles (tendo calcaneus) de ratos, após tenotomia. O grupo controle foi definido como tenotomizados com simulação da aplicação sônica e tendões não tenotomizados. Os dois grupos tratados com ultra-som terapêutico foram no modo pulsado. A irradiação do ultra-som terapêutico foi realizada na freqüência de 1 MHz e uma intensidade de 0.5 Watts por centímetro ao quadrado (SATA), por cinco minutos cada sessão. No 13° dia de pós-operatório, os tendões foram removidos e analisados por meio da microscopia de luz polarizada, com o propósito de investigar e medir a organização das fibras de colágeno, por meio da birrefringência. Os resultados demonstraram que o grupo tratado com a aplicação tópica de hidrocortisona apresentou valores estatísticos similares ao grupo que recebeu simulação sônica, indicando que não houve penetração da hidrocortisona e que as moléculas de colágeno responderam a estimulação ultra-sônica. Tal fato acontece provavelmente originado pelo efeito piezoelétrico que o ultra-som causa no tecido. O tratamento com fonoforese demonstrou ser o método mais eficiente, devido a maior birrefringência, revelando melhor organização e agregação das fibras de colágeno. Esses achados permitem concluir que o ultra-som terapêutico estimula a aceleração do processo de reparo tecidual e induz a penetração transcutânea da hidrocortisona a 10% numa concentração terapêutica / The purpose of this study was to compare the treatment efficacy of topic hydrocortisone appliance, therapeutic ultrasound and phonophoresis on the rats’ Achilles tendon (tendo calcaneus) repair process after tenotomy. The control group was designed in tenotomized with sham sonic application and non-tenotomized tendons. The two treated groups with therapeutic ultrasound was made in a pulsed mode. The irradiation of therapeutic ultrasound was performed at a frequency of 1 MHz and an intensity of 0.5 Watts for square centimeter (SATA), for five minutes each session. On the 13 th postoperative day, the tendons were removed and analyzed using the polarized light microscopy, with the purpose to detect and measure the organization of collagen fibers through birefringence. The results showed that the treated group with the hydrocortisone topic appliance showed similar statistician values of group that received sham sonic treatment, indicating that not have delivery transdermal and that the molecule of collagen respond to the ultrasonic stimulation. This fact occurs probably by piezoelectric effect originated by ultrasound on the tissue. The treatment with phonophoresis demonstrated being the method more efficient, due the high birefringence, revealing the best organization and aggregation of collagen fibers. These findings allow conclude that the therapeutic ultrasound stimulate the acceleration of tissue repair process and induce the transdermal delivery of hydrocortisone 10% in a therapeutic concentration
122

Estabilização segmentar lombar e TENS na hérnia discal lombar: um ensaio clínico randomizado / Lumbar segmental stabilization and TENS in lumbar disc herniation: a randomized controlled trial

França, Fabio Jorge Renovato 01 October 2013 (has links)
INTRODUÇÃO: A hérnia de disco lombar (HDL) acomete cerca de 5% dos pacientes com de dor lombar e o tratamento cirúrgico nestes casos é cada vez menos indicado, optando-se, na maior parte dos casos, pelo conservador. Embora o método estabilização lombar (EL) e a estimulação elétrica nervosa transcutânea (TENS) tenham mostrado bons resultados em indivíduos portadores de dor lombar inespecífica, há escassa literatura que tenha verificado a eficácia destes tratamentos isoladamente em sujeitos acometidos por hérnia de disco lombar. OBJETIVO: Comparar a eficácia dos exercícios de estabilização lombar e da TENS na dor, incapacidade funcional, e capacidade de ativação do músculo transverso do abdome (TrA) de indivíduos com hérnia de disco lombar. METODOLOGIA: Participaram da pesquisa 40 indivíduos com idade variando de 25 a 58 anos com dor lombar e hérnia de disco, e foram randomizados em dois grupos: Grupo estabilização lombar (EL) (exercícios específicos para os músculos TrA e multífido lombar(ML)) (n=20) e Grupo TENS (GT) (n=20) que receberam atendimento com corrente de estimulação elétrica nervosa transcutânea. Foram avaliados quanto à dor (Escala Visual Analógica e Questionário McGill de Dor), incapacidade funcional (Índice de Incapacidade de Oswestry), e capacidade de recrutamento do TrA (Unidade de Biofeedback Pressórico-UBP). Os grupos foram tratados em duas sessões semanais com duração de 60 minutos por oito semanas. Cada indivíduo foi avaliado antes e após o tratamento. O nível de significância estabelecido foi de alfa=0,05. RESULTADOS: Após oito semanas, o grupo estabilização lombar mostrou melhora significativa na dor (p < 0,001), incapacidade funcional (p < 0,001), e capacidade de ativação do TrA (p < 0,001). O grupo TENS apresentou diferença estatisticamente significante apenas na dor (p < 0,012). A estabilização foi superior à TENS na melhora na dor (p < 0,001), incapacidade funcional (p < 0,001), e capacidade de ativação do TrA (p < 0,001). CONCLUSÃO: Os resultados indicam que a estabilização é efetiva na melhora da dor, incapacidade funcional, e capacidade da ativação do TrA, e a TENS apenas na dor. A estabilização foi superior à TENS em todas as variáveis / INTRODUCTION: Lumbar disc herniation (LDH) affects about 5% of low back pain (LBP) patients. Surgical treatment in these cases is increasingly less suitable, opting, in most cases, for the conservative. Although lumbar stabilization method and transcutaneous electric nerve stimulation (TENS) have shown good results in patients with nonspecific low back pain, there is scarce literature that has verified the effectiveness of these treatments alone in subjects suffering from lumbar disc herniation.OBJECTIVE: To compare the effectiveness of lumbar stabilization exercises and transcutaneous electrical nerve stimulation (TENS), on pain, functional disability and activation of the transversus abdominis muscle (TrA), in individuals with lumbar disc herniation (LDH). METHODS: This study involved 40 patients (age range 25-58 years) with lumbar disc herniation randomized into two groups: Stabilization group (SG: n=20); which received of stabilization exercises (transversus abdominis and lumbar multifidus muscles) and TENS group (TG: n=20), which received electrotherapy. The following instruments were used: visual analogue pain scale and McGill Pain Questionnaire for pain, Oswestry Disability Index for functional disability, and pressure biofeedback unit (PBU) for ability to contract the TrA. Analyses within and between groups were performed after treatment. Groups underwent 16 sessions, for 60 minutes, twice a week and they were evaluated before and after eight weeks. Significance level was set at alfa= 0.05. RESULTS: After eight weeks, lumbar stabilization group showed significant improvements in pain (p < 0.001), functional disability (p < 0.001), and the ability to contract the TrA (p < 0.001). There were no significant differences in TENS group in terms of disability (p < 0.264) or ability to contract the TrA muscle (p < 0.181), however, improvement in pain was demonstrated (p < 0.012). The stabilization was superior to TENS in terms of improvements in pain (p < 0.001), functional disability (p < 0.001), and ability to contract the TrA (p < 0.001). CONCLUSION: The results indicate that stabilization is effective in improving pain, functional disability, and the ability to contract the TrA in individuals with LDH. In the TENS group, the only improvement after treatment was in terms of pain. Stabilization was superior to TENS in all outcomes
123

Avaliação das propriedades imunomoduladoras de toxinas termo-lábeis do tipo II produzidas por Escherichia coli enterotoxigênica (ETEC) administradas por via transcutânea. / Evaluation of the immunomodulatory properties of type II heat-labile toxins produced by enterotoxigenic Escherichia coli (ETEC) administered by transcutaneous route.

Santos, Camila Mathias dos 27 May 2009 (has links)
Toxinas termo-lábeis expressas por Escherichia coli enterotoxigênica (LT-I, LT-IIa e LT-IIb) são adjuvantes sistêmicos e de mucosa. Essas proteínas apresentam reduzida identidade (<14%) em suas subunidades B e ligação a receptores distintos, o que pode resultar em propriedades biológicas diferenciais. O objetivo do trabalho foi avaliar a resposta imune induzida pela toxina LT-IIa e seu pentâmero B (LT-IIaB) administradas pelas vias transcutânea e intradérmica. Inicialmente as proteínas foram expressas em E. coli, purificadas e avaliadas quanto à funcionalidade in vitro. Numa segunda etapa, as propriedades imunomoduladoras de LT-IIa e LT-IIaB, imunogenicidade e atividade adjuvante, foram avaliadas em modelo murino. A resposta imune (humoral e celular) induzida contra ovalbumina (OVA), aplicada como antígeno, foi determinada. Os resultados demonstram que as atividades adjuvantes induzidas por LT-IIa e LT-IIaB variam de acordo com a via de inoculação e que as holotoxinas LT-I e LT-IIa induzem graus de inflamação e ativação de resposta imune distintos em camundongos. / Heat-labile toxins expressed by enterotoxigenic Escherichia coli (LT-I, LT-IIa and LT-IIb) are potent systemic and mucosal adjuvants. These proteins have low identity (<14%) in their B subunits and bind to different receptors, which may result in differential biological properties. The objective of this work was to evaluate the immune response induced by LT-IIa toxin and its pentameric B subunit (LT-IIaB) delivered by transcutaneous and intradermic routes. Initially the proteins of interest were expressed in recombinant E. coli strains, purified and tested for functionality in vitro. In a second moment, the immunomodulatory properties of LT-IIa and LT-IIaB, immunogenicity and adjuvant activity, were evaluated in mouse model. The humoral and cellular immune responses induced against ovalbumin (OVA) used as antigen were determined. The results show that the adjuvant activity of LT-IIa and its B pentamer depends on the route of inoculation and that LT-I and LT-IIa differ both on induction of inflammation and activation of immune responses in mice.
124

Eficácia analgésica da estimulação elétrica cerebral e periférica na dor lombar crônica inespecífica: ensaio clínico aleatorizado, duplo-cego, fatorial / Analgesic efficacy of cerebral and peripheral electrical stimulation in chronic nonspecific low back pain: a randomized, double-blind, factorial clinical trial

Hazime, Fuad Ahmad 02 December 2015 (has links)
Recentes evidências sugerem que a dor lombar crônica está associada a alterações plásticas no cérebro, que podem ser modificadas por estratégias de neuromodulação. Neste ensaio clínico investigamos a eficácia analgésica de 12 sessões não consecutivas de estimulação transcraniana por corrente contínua (ETCC), estimulação elétrica periférica (EEP), ETCC+EEP e estimulação simulada (sham) em 92 pacientes com dor lombar crônica inespecífica. A intensidade, aspecto sensorial e afetivo da dor, incapacidade e percepção global de recuperação foram avaliadas antes do tratamento e quatro semanas, três e seis meses pós-randomização. Efeitos adversos, satisfação do paciente com o tratamento e fatores de confusão como ansiedade e depressão também foram avaliados. Os resultados demonstraram efeitos analgésicos clinicamente importantes da ETCC+EEP (MD = -2,6 IC95% = -4,4 a -0,9) e EEP isolada (MD = -2,2 IC95% = -3,9 a -0,4) comparada ao grupo sham, mas não da ETCC isolada (MD = -1,7 IC95% = -3,4 a -0,0). Além da manutenção do efeito analgésico por até três meses a ETCC+EEP obteve maior proporção de respondedores em diferentes pontos de corte. Os resultados sugerem que tanto a ETCC+EEP quanto EEP isolada são eficazes em curto prazo para o alívio da dor lombar crônica inespecífica. No entanto o efeito analgésico mais duradouro aliado a maior proporção de respondedores indicam um possível efeito aditivo e sinérgico da ETCC+EEP no alívio da dor em pacientes com dor lombar crônica não específica. Os nossos resultados não apoiam o uso da ETCC no regime de tratamento utilizado / Recent evidence suggests that chronic low back pain is associated with plastic changes in the brain that can be modified by neuromodulation strategies. In this clinical trial we have investigated the analgesic efficacy of 12 non-consecutive sessions of transcranial direct current stimulation (tDCS), peripheral electrical stimulation (PES), tDCS+PES and sham stimulation in 92 patients with chronic nonspecific low back pain. Intensity, the sensory and affective aspect of pain, disability, and overall perception of recovery were assessed before treatment and four weeks, three and six months post-randomization. Adverse effects, patient satisfaction with treatment and confounding factors such as anxiety and depression were also evaluated. The results showed clinically significant analgesic effects of tDCS+PES (Mean Reduction (MR) = -2.6; CI95% = -4.4 to - 0.9) and PES alone (MD = -2.2, CI95% = -3.9 to -0.4) compared to sham group, but not tDCS alone (MD = -1.7, CI95% = -3.4 to -0.0). In addition to maintaining the analgesic effect for up to three months, tDCS+PES treatment had a higher proportion of responders in different cutoff points. The results suggest that both tDCS+PES and PES alone are effective in relieving chronic nonspecific low back pain in the short term. However the most lasting analgesic effect, combined with a higher proportion of responders, indicates a possible additive and synergistic effect of tDCS+PES in relieving low back pain. Our findings do not support the use of tDCS alone in this condition
125

Biofeedback EMG ou eletroestimulação transcutânea parassacral em crianças com disfunção do trato urinário inferior: estudo prospectivo e randomizado / EMG Biofeedback or parasacral transcutaneous eletrical nerve stimulation in children with lower urinary tract dysfunction: study prospective randomized

Reis, Joceara Neves dos 30 November 2015 (has links)
INTRODUÇÃO: A disfunção do trato urinário inferior (DTUI) pode decorrer de contrações vesicais durante a fase de enchimento (hiperatividade do detrusor) ou a falta de coordenação entre a contração vesical e o relaxamento dos músculos do assoalho pélvico durante o esvaziamento vesical (disfunção miccional). Várias publicações sugerem benefícios do uso de biofeedback eletromiográfico (EMG) e eletroestimulação transcutânea parassacral (ENTP) no tratamento destas condições. Contudo faltam estudos controlados comparando estas duas formas de tratamento. OBJETIVO: Comparar a eficácia das técnicas de biofeedback EMG e ENTP em crianças com DTUI. MÉTODOS: Estudo prospectivo e randomizado com 64 crianças, sendo 43 meninas e 21 meninos com idade média 9,39 anos. As crianças foram divididas em dois grupos de tratamento: grupo biofeedback (GB) e grupo de ENTP (GE). Os critérios para avaliar a eficácia do tratamento foram a taxa de resolução dos sintomas noturnos e diurnos, comprovados por diário miccional, urofluxometria, questionários (DVSS - Dysfunction voiding symptoms score), avaliação da qualidade de vida (QV), melhora da constipação e do número de episódios de infecção do trato urinário (ITU).RESULTADOS: No GB 54,9% das crianças tiveram resposta completa e no GE 60,6% em relação a melhora diurna (p=0,483) e 29,6% e 25% em relação a melhora noturna respectivamente (p=0,461). Em relação ao diário miccional, urofluxometria e DVSS, ambos os grupos tiveram melhora estatisticamente significante (p=0,001), porém a QV não teve diferença entre os grupos (p=0,959 e p=0,065). Na avaliação da constipação, houve decréscimo no GB de 61,3% para 19,4% (p=0,002) e no GE de 33,3% para 6,2% (p=0,013). Nenhuma criança apresentou ITU após o término do tratamento (p < 001). CONCLUSÃO: O biofeedback EMG e a ENTP são efetivos para o tratamento de DTUI.Esta eficácia se traduz por melhora dos sintomas diurnos e noturnos bem como na avaliação feita por questionário e urofluxometria. Ambas as técnicas se mostrarm eficazes, embora o biofeedback tenha requerido um menor número de sessões / INTRODUCTION: The lower urinary tract dysfunction (LUTD) may be due to bladder contractions during the filling phase (detrusor overactivity) or the lack of coordination between bladder contraction and relaxation of the pelvic floor muscles during bladder emptying (voiding dysfunction ). Several publications have suggested benefits of using electromyographic biofeedback (EMG) and parasacral transcutaneous electrical nerve stimulation (TENS) in treating these conditions. However there is a lack of controlled studies comparing these two forms of treatment. OBJECTIVE: To compare the effectiveness of EMG biofeedback and parasacral TENS techniques in children with DTUI. METHODS: A prospective and randomized study with 64 children, 43 girls and 21 boys, mean age 9.39 years. The children were divided into two treatment groups: biofeedback group and parasacral TENS. The criteria for assessing the effectiveness of techniques were the rate of resolution of daytime and nighttime symptoms, improvements in voiding diary, uroflowmetry and questionnaires. (DVSS - Dysfunction voiding symptoms score). We also acessed changes in quality of life (QOL) constipation and number of episodes of lower urinary tract infection (UTI). RESULTS: GB 54.9% of children had complete response in EMG biofeedback group and 60.6% in those treated by parasacral TENS in daytime symptoms (p = 0.483) and 29.6% and 25% in night time respectively (p = 0.461). Regarding the voiding diary, uroflowmetry and DVSS, both groups had statistically significant improvement (p = 0.001), but the QOL showed no difference between groups (p = 0.959 and p = 0.065). In the evaluation of constipation, there was a decrease in EMG biofeedback group 61.3% to 19.4% (p = 0.002) and in parasacral TENS group 33.3% to 6.2% (p = 0.013). No child had UTI after the end of treatment (p <.001). CONCLUSION: EMG biofeedback and the parasacral TENS are effective for treating DTUI. This efficiency translates into improved daytime and nighttime symptoms as well as in the evaluation made by questionnaire and uroflowmetry. Both techniques showed excellent results, although biofeedback required a fewer number of sessions
126

Uso da Estimulação Elétrica Nervosa Transcutânea (TENS) na redução dos sintomas de neuropatia periférica induzida por quimioterapia anti-neoplásica / Transcutaneous Electrical Nerve Stimulation (TENS) in reducing the symptoms of chemotherapy induced peripheral neuropathy

Tonezzer, Tania 16 December 2016 (has links)
INTRODUÇÃO: A neuropatia periférica induzida por quimioterapia (NPIQ) está entre os efeitos colaterais mais comuns decorrentes da quimioterapia antineoplásica e uma das principais causas da redução da dose ou interrupção do tratamento. Os sintomas mais prevalentes são a dor e a parestesia, acarretando desconfortos crônicos e perda de habilidades funcionais, interferindo negativamente na qualidade de vida dos pacientes. Estudos recentes têm avaliado o uso da Estimulação Elétrica Nervosa Transcutânea (TENS) nesta patologia, apresentando evidências positivas na redução da dor, porém seu efeito nos sintomas de parestesia e nas atividades de vida diária destes pacientes ainda não foram avaliados. OBJETIVO: Investigar os efeitos da Estimulação Elétrica Nervosa Transcutânea (TENS) nos sintomas de dor, parestesia e nas atividades de vida diária da NPIQ em indivíduos com diagnóstico de câncer de mama e colorretal, submetidos ao tratamento de quimioterapia. MÉTODOS: Trata-se de um ensaio clínico duplo-cego, controlado, randomizado e multicêntrico, com abordagem quantitativa, em pacientes submetidos ao tratamento de quimioterapia, contendo em seu protocolo os seguintes quimioterápicos: paclitaxel e oxaliplatina. Os sujeitos da pesquisa utilizaram o dispositivo terapêutico TENS com modulação de frequência entre 7 e 75 Hz na região distal dos membros, no local de maior desconforto, com intervenções diárias de 60 minutos, durante três ciclos de quimioterapia (45 dias). Os participantes foram divididos em dois grupos: grupo TENS ativa (GTA) e grupo TENS placebo (GTP). A avaliação dos efeitos da TENS foi medida através dos seguintes instrumentos: a Escala Visual Analógica (EVA) para avaliar os sintomas de dor e parestesia e Questionário de Neurotoxicidade Induzida por Anti-neoplásicos (QNIA) para avaliação dos sintomas da NPIQ. RESULTADOS: Finalizaram a pesquisa 24 pacientes. Não se observou uma diferença significativa entre os 2 grupos no que se refere ao desfecho primário de redução dos sintomas de dor (p = 0.666), parestesia (p = 0,673) e impacto da TENS na frequência dos sintomas (p = 0,5906) e atividades de vida diária (p = 0,8565). CONCLUSÃO: Estes resultados sugerem que a TENS aplicada no modo de modulação de frequência não foi eficaz para melhorar os sintomas de neuropatia periférica induzida por quimioterapia, durante os ciclos de quimioterapia. Não houve, porém, agravamento dos sintomas em ciclos subsequentes ao início dos sintomas da doença / BACKGROUND: Peripheral neuropathy induced by chemotherapy (PNIC) is amongst the most common side effects derived from antineoplastic chemotherapy and one of the principal causes of dose reduction or treatment interruption. The most prevalent symptoms are pain and numbness, resulting from chronic discomfort to loss of functional abilities, negatively affecting quality of life and autonomy of patients. Recent studies have evaluated the use of Transcutaneous Electrical Nerve Stimulation (TENS) in this disease, pointing to evidence of pain reduction, but its effect on symptoms of paresthesia and in daily life activities have not yet been evaluated. OBJECTIVE: To investigate the effects of Transcutaneous Electrical Nerve Stimulation (TENS) for reducing the symptoms of pain, paresthesia and the daily activities of PNIC in patients diagnosed with breast cancer and colorectal cancer undergoing chemotherapy treatment. METHODS: It is a double-blind, controlled, randomized, multicenter clinical trial with a quantitative approach in a sample of 24 patients undergoing chemotherapy treatment, containing in its protocol the following chemotherapeutic agents: paclitaxel and oxaliplatin. The research subjects used the TENS therapeutic device with frequency modulation between 7 and 75 Hz in the distal limb, on the location of greatest discomfort with daily interventions lasting 60 minutes for three chemotherapy cycles (45 days). Participants were divided into two groups: active TENS group (ATG) and placebo TENS group (PTG). The assessment of the effects of TENS was measured by the following instruments: The Visual Analogue Scale (VAS) to assess the symptoms of pain and numbness and Questionnaire for Neurotoxicity Induced by Anti-neoplastic (QNIA) to assess the symptoms of PNIC. RESULTS: A 24-patient study was completed. There was no significant difference between the two groups regarding the primary endpoint of reduced pain symptoms (p = 0.666) and paresthesia (p = 0.673), neither any measurable impact of TENS in the frequency of symptoms (p = 0.5906) or activities of daily living (p = 0.8565). CONCLUSION: These results suggest that TENS applied in frequency modulation mode is not effective for ameliorating the symptoms of peripheral neuropathy induced by chemotherapy during chemotherapy cycles. There was, however, no worsening of symptoms in subsequent cycles after the onset of symptoms
127

Eficácia analgésica da estimulação elétrica cerebral e periférica na dor lombar crônica inespecífica: ensaio clínico aleatorizado, duplo-cego, fatorial / Analgesic efficacy of cerebral and peripheral electrical stimulation in chronic nonspecific low back pain: a randomized, double-blind, factorial clinical trial

Fuad Ahmad Hazime 02 December 2015 (has links)
Recentes evidências sugerem que a dor lombar crônica está associada a alterações plásticas no cérebro, que podem ser modificadas por estratégias de neuromodulação. Neste ensaio clínico investigamos a eficácia analgésica de 12 sessões não consecutivas de estimulação transcraniana por corrente contínua (ETCC), estimulação elétrica periférica (EEP), ETCC+EEP e estimulação simulada (sham) em 92 pacientes com dor lombar crônica inespecífica. A intensidade, aspecto sensorial e afetivo da dor, incapacidade e percepção global de recuperação foram avaliadas antes do tratamento e quatro semanas, três e seis meses pós-randomização. Efeitos adversos, satisfação do paciente com o tratamento e fatores de confusão como ansiedade e depressão também foram avaliados. Os resultados demonstraram efeitos analgésicos clinicamente importantes da ETCC+EEP (MD = -2,6 IC95% = -4,4 a -0,9) e EEP isolada (MD = -2,2 IC95% = -3,9 a -0,4) comparada ao grupo sham, mas não da ETCC isolada (MD = -1,7 IC95% = -3,4 a -0,0). Além da manutenção do efeito analgésico por até três meses a ETCC+EEP obteve maior proporção de respondedores em diferentes pontos de corte. Os resultados sugerem que tanto a ETCC+EEP quanto EEP isolada são eficazes em curto prazo para o alívio da dor lombar crônica inespecífica. No entanto o efeito analgésico mais duradouro aliado a maior proporção de respondedores indicam um possível efeito aditivo e sinérgico da ETCC+EEP no alívio da dor em pacientes com dor lombar crônica não específica. Os nossos resultados não apoiam o uso da ETCC no regime de tratamento utilizado / Recent evidence suggests that chronic low back pain is associated with plastic changes in the brain that can be modified by neuromodulation strategies. In this clinical trial we have investigated the analgesic efficacy of 12 non-consecutive sessions of transcranial direct current stimulation (tDCS), peripheral electrical stimulation (PES), tDCS+PES and sham stimulation in 92 patients with chronic nonspecific low back pain. Intensity, the sensory and affective aspect of pain, disability, and overall perception of recovery were assessed before treatment and four weeks, three and six months post-randomization. Adverse effects, patient satisfaction with treatment and confounding factors such as anxiety and depression were also evaluated. The results showed clinically significant analgesic effects of tDCS+PES (Mean Reduction (MR) = -2.6; CI95% = -4.4 to - 0.9) and PES alone (MD = -2.2, CI95% = -3.9 to -0.4) compared to sham group, but not tDCS alone (MD = -1.7, CI95% = -3.4 to -0.0). In addition to maintaining the analgesic effect for up to three months, tDCS+PES treatment had a higher proportion of responders in different cutoff points. The results suggest that both tDCS+PES and PES alone are effective in relieving chronic nonspecific low back pain in the short term. However the most lasting analgesic effect, combined with a higher proportion of responders, indicates a possible additive and synergistic effect of tDCS+PES in relieving low back pain. Our findings do not support the use of tDCS alone in this condition
128

Influência dos parâmetros estimulatórios na eficiência da contração muscular evocada pela estimulação elétrica funcional em pessoas hígidas ou com lesão medular

Beck, Eddy Krueger 08 October 2010 (has links)
CAPES / Introdução: A estimulação elétrica funcional (FES) é aplicada a pessoas portadoras de lesão medular (LM) com o objetivo de gerar movimentos funcionais artificialmente. A Mecanomiografia (MMG) mede a oscilação do músculo durante a contração. Os padrões estimulatórios são determinados pelos parâmetros: períodos on e off do pulso e do burst e suas amplitudes. Durante a sessão de aplicação da FES, o tecido neuromuscular responde de forma variada em decorrência de alterações fisiológicas como fadiga muscular e/ou adaptação do motoneurônio. Objetivo: na pesquisa desenvolvida, investigou-se a influência dos parâmetros estimulatórios na eficiência da contração muscular evocada pela FES em voluntários hígidos e portadores de lesão medular. Materiais e Métodos: participaram da pesquisa 10 voluntários hígidos (VHs) e 10 voluntários com LM (VLMs) com sensores de MMG posicionados sobre os ventres musculares dos músculos reto femoral e vasto lateral. Os estímulos elétricos foram aplicados sobre o nervo femoral para ativação do músculo quadríceps. Foram testados cinco padrões estimulatórios em dias diferentes, com oito contrações evocadas artificialmente e divididas em duas sessões com intervalo de 15 min entre elas. Resultados: foi proposto um índice de eficiência de FES com (1) o tempo de estimulação, (2) a menor variação angular e (3) a menor divergência dos descritores de MMG: frequência mediana (Median Frequency) e valor eficaz (Root Mean Square). Os padrões estimulatórios que apresentaram maior eficiência são os de 50 Hz para VHs e 70 Hz para VLMs, por manterem a contração evocada artificialmente por (1) maior tempo, com menor (2) variação angular e (3) resposta mecanomiográfica com menor alteração. Conclusões: conclui-se que os padrões estimulatórios empregando frequências de 50 Hz para VHs e de 70 Hz para VLMs foram mais eficientes na contração artificial por meio da FES. / Introduction: Functional electrical stimulation (FES) is applied to people with spinal cord injury (SCI) in order to artificially evoque functional movements. Mechanomyography (MMG) measures the oscillation of the muscle during contraction. The stimulatory profiles are controlled by the parameters: active and rest periods of the pulse and the burst and their amplitude. During the period of application of FES, the neuromuscular tissue responds in different ways, due to physiological changes such as muscle fatigue and/or adaptation of motor neurons. Objective: In the research developed, we investigated the influence of simulatory parameters on the efficiency of muscle contraction evoked by FES in healthy volunteers and patients with spinal cord injury. Materials and Methods: The healthy volunteers (HV) and ten subjects with SCI participated of the study. The MMG sensors were placed over the belly of the rectus femoris muscle and vastus lateralis. The electrical stimuli were yielded on the femoral nerve in order to activate quadriceps muscle. Five FES profiles were tested on different days with eight artificially evoked contractions divided into two sessions with an interval of fifteen minutes apart. Results: was proposed a FES efficiency index based on (1) stimulation time, (2) lower angular variation and (3) lower divergence of MMG descriptors: Median Frequency (MF) and Root Mean Square (RMS) value. FES profiles that showed better efficiency are: burst frequency of 50 Hz for HV and 70 Hz for SCI volunteers. They kept the contraction artificially evoked for (1) longer time, (2) lower angular variation of and (3) mechanomyographic response with minor modification. Conclusions: we conclude thar stimulatory profiles using frequencies of 50 Hz for HV and 70 Hz for SCI volunteers were more efficient for evoking contraction artificially.
129

Efeito de técnicas de neuromodulação sobre parâmetros bioquímicos e neurofisiológicos em pacientes com dor crônica musculoesquelética

Medeiros, Liciane Fernandes January 2014 (has links)
A dor crônica musculoesquelética é um importante problema de saúde pública, pois, além de ter alta prevalência, suas consequências são nefastas à condição física, psicológica e comportamental, levando ao afastamento do trabalho e aposentadoria precoce. Considerando que quadros de dor crônica são relacionados a alterações biológicas em importantes sistemas endógenos, a busca de biomarcadores sistêmicos interrelacionados com este processo podeser útil para o entendimento dos possíveis efeitos terapêuticos e adversos de técnicas de neuromodulacão, tanto centrais quanto periféricas. Baseado nisto, o objetivo principal deste estudo foi avaliar o efeito dos tratamentos com estimulação magnética transcraniana repetitiva (rTMS) e eletroestimulação intramuscular (DIMST) na intensidade da dor e em parâmetros bioquímicos e neurofisiológicos em pacientes com dor crônica musculoesquelética,e, secundariamente, buscar possíveis biomarcadores em quadros de dor crônica musculoesquelética. Este estudo foi dividido em dois experimentos. No experimento 1, comparou-se o efeito das técnicas de neuromodulação periférica (DIMST) e central (rTMS) sobre os parâmetros de excitabilidade cortical e níveis séricos de BDNF, S100β, citocinas e parâmetros de estresse oxidativo em pacientes com SDM. Foram recrutadas 46 mulheres, com idade entre 19 e 75 anos e diagnóstico de síndrome dolorosa miofascial (SDM). Trata-se de um ensaio clínico randomizado, cego, em paralelo, controlado com placebo-sham. As pacientes foram randomizadas em 4 grupos: (1) rTMS+DIMST, (2) rTMS +sham-DIMST, (3) sham-rTMS+DIMST e (4) sham-rTMS + sham-DIMST. No experimento 2, avaliou-se parâmetros neurofisiológicos de excitabilidade cortical e níveis séricos de BDNF como marcadores de dor crônica musculoesquelética. Foram recrutadas 72 mulheres, com idade entre 19 e 75 anos e diagnóstico de osteoartrite (OA) e SDM. Os parâmetros mensurados foram: dor pela escala análogo-visual (EAV), limiar de dor por algometria (PPT) e excitabilidade cortical pelo TMS. No experimento 1, as pacientes mostrarem-se iguais entre os grupos no basal. Houve uma redução na dor mensurada pela EAV nos grupos 1, 2 e 3 em relação ao grupo 4. O parâmetro de excitabilidade, potencial evocado motor (MEP), apresentou um aumento de amplitude ao final da intervenção 2. Não foram observadas mudanças nos parâmetros bioquímicos analisados durante e ao final das intervenções, seja entre as intervenções e dentro das intervenções. No experimento 2, observou-se que o PPT apresenta uma correlação positiva com inibição intracortical (ICI) e negativa com a facilitação intracortical (ICF). As pacientes com SDM apresentam o período silente (CSP) mais longo que pacientes com OA. O BDNF e estradiol apresentam relação positiva com PPT; no entanto, quando foi avaliada a interação destes fatores, o efeito sobre o PPT foi em direção oposta. Em resumo, os tratamentos ativos, central e/ou periférico, mostraram-se eficazes no alívio da dor, porém, dentre os parâmetros bioquímicos analisados, não se observouum biomarcador responsivo a estas técnicas. Sugere-se uma relação entre dor crônica musculoesquelética e alterações na excitabilidade cortical do córtex motor. Além disto, é importante ressaltar que estes tratamentos não alteraram nenhum dos parâmetros de avaliação de dano celular, como, por exemplo, o aumento de proteína glial (S100β), sugerindo que são técnicas seguras no que se refere aos parâmetros avaliados nesta tese. Posteriores estudos são necessários buscando novos biomarcadores que permitam um melhor diagnóstico, prognóstico e avaliação da resposta ao tratamento com técnicas de neuromodulação na dor crônica musculoesquelética. / Chronic musculoskeletal pain is a major public health problem with high prevalence, because, besides its high prevalences, its consequences are harmful to the physical, psychological and behavioral condition, leading to absence from work and early retirement. Taking into account that chronic pain processes are related to biological changes in endogenous systems, searching systemic biomarkers interconnected with this process can be useful to understand the potential therapeutic and adverse effects of the neuromodulation techniques, both central and peripheral. Based on that, the aim of this study was to evaluate the effect of treatment with repetitive transcranial magnetic stimulation (rTMS) and intramuscular electrical stimulation (DIMST) on pain intensity, biochemical and neurophysiological parameters in chronic musculoskeletal pain patients. Secondly, the aim was to find possible biomarkers in chronic musculoskeletal pain conditions. This study was divided into two protocols. Protocol 1, it was compared the effect of central (rTMS) and peripheral (DIMST) neuromodulation techniques on pain intensity, cortical excitability parameters and serum levels of BDNF, S100β, cytokines and oxidative stress parameters in patients with myofascial pain syndrome (MPS.) Fourty women, aged between 19 and 75 years, MPS diagnosis were recruited. This is a randomized, blind, parallel, placebo - sham clinical trial. The patients were randomized into four groups: (1) rTMS + DIMST, (2) rTMS + sham-DIMST, (3) sham-rTMS + DIMST, and (4) sham-rTMS + sham-DIMST. Protocol 2, we assessed the neurophysiological parameters of cortical excitability and BDNF serum levels as markers of chronic musculoskeletal pain. Seventy-two women, aged between 19 and 75 years diagnosed with osteoarthritis (OA) and MPS were recruited. The measured parameters were: pain intensity by visual analogue scale (VAS), pain pressure threshold (PPT) and cortical excitability by TMS. In protocol 1, the patients presented similarities in the baseline between the four groups. The patients presented a reduction in painintensity measured by VAS in the groups 1, 2 and 3 in relation to group 4. After rTMS intervention, there was an increase in the MEP amplitude. There were no changes in biochemical parameters analyzed during and after the interventions. In protocol 2, it was observed that PPT has a positive correlation with intracortical inhibition (ICI) and negative correlation with intracortical facilitation (ICF). Patients with MPS exhibit longer silent period (CSP) than OA patients. BDNF and estradiol serum levels presented a positive correlation with PPT; however, when their interaction was assessed, the effect on the PPT was in the opposite direction. In summary, the active, central and/ or peripheral treatments were effective in relieving the pain; however, among the biochemical parameters analyzed, there was no biomarker responsive to these techniques. It is suggested a relationship between chronic musculoskeletal pain and changes in cortical excitability of the motor cortex. Furthermore, it is important to note that these treatments did not alter any of the parameters of cellular damage assessment, such as the increase of glial protein (S100β), suggesting that they are safe as to the parameters evaluated in these techniques. Further studies are needed to find new biomarkers that allow better diagnosis, prognosis and assessment of treatment response with neuromodulation techniques in chronic musculoskeletal pain.
130

Tratamento da hiperatividade vesical e incontinência de urgência empregando neuromodulação do nervo tibial posterior e exercícios pélvicos

Bruel, Tatiane Martinez e Silva 12 September 2014 (has links)
A incontinência urinária é considerada um problema mundial. Estima-se que ela afeta 30% da população feminina adulta, comprometendo a qualidade de vida destas mulheres. Os tratamentos conservadores de incontinência urinária, no geral, têm custo menor e não apresentam efeitos colaterais. A partir da proposta de um estudo multicêntrico, definiu-se a presente pesquisa com o objetivo de verificar a efetividade das técnicas de estimulação elétrica por neuromodulação do nervo tibial posterior e exercícios pélvicos no tratamento da hiperatividade vesical incontinência de urgência/mista. O equipamento utilizado foi desenvolvido pela equipe do Hospital de Clínicas de Porto Alegre e tem a capacidade de armazenar em memória os períodos de utilização bem como a intensidade ajustada pela paciente em ambiente domiciliar. Por meio do equipamento, estimula-se eletricamente, de forma intensiva, o nervo tibial posterior; já os exercícios pélvicos foram elaborados a fim de comparar a efetividade das técnicas. Para o ensaio clínico, foram selecionadas 26 mulheres, divididas em dois grupos que foram submetidas a um protocolo de dezesseis semanas (Grupo A: as primeiras oito semanas para a aplicação da estimulação tibial e as demais oito semanas para a realização dos exercícios da musculatura do assoalho pélvico; e Grupo B: as primeiras oito semanas para a realização dos exercícios da musculatura do assoalho pélvico e oito semanas para a estimulação tibial), em ambiente domiciliar. A cada período de oito semanas do tratamento, as voluntárias preencheram um questionário de qualidade de vida e um questionário de gravidade da incontinência urinária. Constatou-se, por meio do questionário de gravidade de incontinência urinária, uma redução das perdas urinárias, nas primeiras oito semanas do Grupo A que correspondiam ao tratamento com estimulação elétrica. 78,6% das voluntárias melhoraram, enquanto 21,4% não perceberam nenhum qualquer resultado. Nas últimas oito semanas que correspondia ao tratamento com exercícios do assoalho pélvico 78,6% não perceberam qualquer efeito e 21,4% relataram piorara nos sintomas de incontinência urinária. No Grupo B, nas primeiras oito semanas, de exercícios terapêuticos, 50% das voluntárias relataram piora nos sintomas, 33% não perceberam qualquer efeito e 16,7% melhoraram dos sintomas de incontinência urinária. Ao final das oito semanas, que correspondia ao tratamento com estimulação elétrica, 8,4% não perceberam qualquer efeito e 91,6% relataram melhora nos sintomas da incontinência urinária. Ao comparar-se as duas técnicas, verificou-se que enquanto as pacientes foram submetidas ao tratamento com estimulação elétrica, houve melhora significativa a percepção de incontinência urinária. A técnica de estimulação por neuromodulação do nervo tibial posterior com a nova instrumentação desenvolvida para uso domiciliar mostrou-se eficiente na minimização dos sintomas de incontinência urinária. / The urinary incontinence is a worldwide problem. Statistical data indicates that it affects 30% of the adult female population, compromising the quality of life of these women. Conservative treatments for urinary incontinence, in general, are cheaper and they do not cause side effects. For the proposition of a multicenter study, this research was defined aiming to investigate how effective the electric stimulation technique by using neuromodulation of the posterior tibial nerve and pelvic exercises is in the treatment of urgency/mixed bladder hyperactivity incontinence. The equipment used in the research had been developed by the biomedical engineering team of the Hospital de Clínicas at Porto Alegre. It can store in memory the period of time in which the equipment has been used as well as the stimuli intensity adjusted by the patient. By means of the equipment, we intensively stimulated electrically the patient’s posterior tibial nerve. Pelvic exercises were prescribed in order to assess the effectiveness of the neuromodulation technique. For the clinical trial, 26 women were selected and they were divided in two groups, both submitted to a sixteen weeks protocol, applied at home. During the first eight weeks, Group A was submitted to the electrical stimulation and on the remaining eight weeks, to exercises of the pelvic floor muscles. Differently, volunteers of Group B performed exercises during the first eight weeks and electrical stimulation on the last eight weeks. In each period of eight weeks of treatment, the volunteers answered the King’s Health Questionnaire and the Incontinence Severity Index Questionnaire. The analysis of the Incontinence Severity Index Questionnaire results presented a reduction in the urinary output. For Group A, in the first eight weeks (electrical stimulation), 78.6% of the volunteers reported improvement while 21.4% reported no effects. In the last eight weeks (exercises), 78.6% perceived no effects and 21.4% have the symptoms worsened. In the first eight weeks of the Group B (exercises), 50% of volunteers reported the worsening of symptoms and 33% felt no effects and 16,7% reported a reduction in the symptoms. In the last eight weeks (electrical stimulation), 8.4% perceived no effects and 91.6% reported improvements. By comparing the two techniques, we verified that while the patients were submitted to the application of electrical stimulation, there was significant improvement on the perception of urinary incontinence. The technique of stimulation by neuromodulation of posterior tibial nerve with the novel instrumentation developed for homecare was efficient and the participants of the study reported significant improvement in their condition.

Page generated in 0.0865 seconds