• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 13
  • 7
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 61
  • 61
  • 61
  • 26
  • 24
  • 21
  • 21
  • 20
  • 17
  • 13
  • 13
  • 12
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Characterization of proteins found in serum and sputum samples from ventilator associated pneumonia patients

Yenuga, Hima Priya 29 May 2020 (has links)
No description available.
32

Vilka munvårdsåtgärder är effektiva som prevention mot ventilatorassocierad pneumoni? : En litteraturöversikt

Einholt, Andreas, Wilhelmsson, Viktoria January 2023 (has links)
Bakgrund: Munhälsan hos intuberade patienter försämras successivt under vårdtiden. Risken att drabbas av VAP ökar dagligen och VAP anses vara en av de vanligaste komplikationerna till respiratorvård och patienter som drabbas kräver längre vårdtid. Munvård är en del av VAP-preventionen men det framgår inte vilka specifika munvårdsåtgärder som har effekt.    Syfte: Syftet med denna uppsats är att beskriva vilka munvårdsåtgärder som är mest effektiva avseende preventionen av VAP och därmed bör användas i intensivvårdssjuksköterskans dagliga arbete.   Metod: En systematisk litteraturöversikt med kvantitativ induktiv ansats. Sammanlagt 17 studier inkluderades i denna uppsats.    Resultat: Två huvudkategorier identifierades samt två subkategorier. Införandet av munvårdsprotokoll gav en statistiskt signifikant minskning av VAP-prevalens, klorhexidin kan vara effektivt mot VAP men det finns även andra antibakteriella lösningar som effektivt förebygger VAP.    Slutsats: För att bidra till ökad patientsäkerhet borde specialistsjuksköterskor inom intensivvård använda ett munvårdsprotokoll för att arbeta preventivt mot VAP. Utöver detta ska tandborstar regelbundet bytas ut, verksamheten borde även se över möjligheten att inkludera tandläkare. Dock är det aktuellt med ytterligare forskning om munvård för att i framtiden använda endast de munvårdsåtgärder som bevisats vara effektiva. / Background: The oral hygiene in intubated patients successively deteriorates during the period of care. The risk of contracting a VAP increases daily and VAP is considered to be one of the most common complications related to mechanical ventilation. The patients who are afflicted require a prolonged hospital stay. Oral hygiene is a part of VAP-prevention but it remains unclear as to which specific oral care measures are effective.    Aim: The aim of this study is to describe which oral care measures are the most effective in the prevention of VAP and therefore should be used by the intensive care nurse in the daily working routine.    Method: A systematic literature study with a qualitative inductive approach was used. A total of 17 studies were included in this essay.   Results: Two main categories were identified as well as two subcategories. The adoption of oral care protocols showed a statistically significant decrease of VAP, and chlorhexidine can be effective against VAP however there are also other antibacterial solutions which effectively prevent VAP.   Conclusion: In order to contribute to increased patient safety intensive care nurses should use an oral care protocol to prevent VAP. In addition to the protocol toothbrushes should be replaced regularly, and the ward should oversee the possibility of including dentists to optimize the oral care. Oral care requires additional research so that in the future it is possible to use only the oral care procedures that have been proven to be effective.
33

Analysis of Ventilator Associated Pneumonia Patients' Hospital and Intensive Care Charges, Length of Stay and Mortality

Lipovich, Carol Jean 08 August 2013 (has links)
No description available.
34

Étude de la nébulisation de deux antibiotiques en ventilation mécanique / Nebulization of two antibiotics during mechanical ventilation

Boisson, Matthieu 29 November 2016 (has links)
Les pneumopathies acquises sous ventilation mécanique (PAVM) sont responsables d'une mortalité élevée. La nébulisation d'antibiotiques permet d'améliorer l'efficacité de leur traitement. Pour autant, aucune donnée pharmacocinétique portant sur la colistine et la gentamicine ne permet de recommander un schéma posologique particulier.Nous avons comparé les propriétés pharmacocinétiques plasmatique et intra-pulmonaire de la colistine (administrée sous forme de prodrogue, le colistiméthate sodique ou CMS) et de la gentamicine selon le mode d'administration (nébulisation ou perfusion intraveineuse) chez des patients de réanimation présentant une PAVM.Les concentrations intra-pulmonaires de colistine et de gentamicine étaient, respectivement, de 10 à 40 et 50 à 70 fois supérieures, après nébulisation, à celles retrouvées après administration d'une même dose par voie intraveineuse. La nébulisation permettrait également de limiter le risque de toxicité systémique avec une biodisponibilité inférieure à 10%.En assurant de fortes concentrations intra-pulmonaires et un faible passage systémique, la nébulisation de CMS et de gentamicine pourrait être une bonne alternative à leur administration intraveineuse dans le traitement des PAVM. / Ventilator-associated pneumonia (VAP) is associated with high mortality. Nebulization of antibiotics improves outcome of patient with VAP. However, pharmacokinetic data concerning colistin and gentamicin allowing for optimal dosing regimen recommendation are lacking.We compared systemic and pulmonary concentrations of colistin (administered as an inactive prodrug, colistin methanesulfonate or CMS) and gentamicin according to the route of administration (nebulization and intravenous infusion) in critically ill patients with VAP.Intra-pulmonary concentrations of colistin and gentamicin were 10 to 40-fold and 50 to 70-fold much higher after nebulization than after the same dose by intravenous route, respectively. Nebulization has also the theoretical potential advantage to improve patients' safety in relation to the colistin biodisponibility lower than 10%.With high intra-pulmonary concentrations and very low systemic absorption, CMS and gentamicin nebulization may be good alternatives to intravenous infusion for VAP treatment.
35

Etude de la nébulisation de téicoplanine en ventilation mécanique / Nebulization of teicoplanin during mechanical ventilation

Chevallot-Béroux, Emmanuelle 16 December 2013 (has links)
La teicoplanine est utilisée par voie intraveineuse (IV) dans le traitement de la pneumonie acquise sous ventilation mécanique (PAVM) à Staphylocoque aureus méticilline résistant. Nous avons évalué la faisabilité et les bénéfices de la nébulisation de teicoplanine en ventilation mécanique (VM) par rapport à la voie IV. L’administration d’un aérosol de teicoplanine chez le rat a permis d’obtenir des concentrations pulmonaires 48 fois supérieures à celles après IV et des concentrations plasmatiques inférieures à celles après IV. Après avoir mesuré l’influence des nébuliseurs sur les paramètres ventilatoires du respirateur, nous avons sélectionné le nébuliseur Aeroneb Pro®. Les propriétés bactériologiques de l’antibiotique ne sont pas altérées par le nébuliseur et l’exposition d’un modèle d’épithélium pulmonaire in vitro à des doses 100 fois supérieures à celles utilisées en IV n’a pas montré de cytotoxicité. L’étude réalisée sur la nébulisation de teicoplanine chez le porc en VM a montré un dépôt pulmonaire moyen de 18,1%. En conclusion, la nébulisation de teicoplanine pourrait etre envisagée comme une nouvelle arme thérapeutique dans la PAVM. / Nebulization of teicoplanin should be an alternative way of administration in Ventilator-associated pneumonia (VAP) caused by Methicillin-resistant staphylococcus aureus. We assessed the faisibility and advantages of nebulization of teicoplanin in mechanical ventilation. After a nebulization of teicoplanin in a rat model, the lung concentrations were more than 48 times higher than the lung concentrations following intravenous administration. In the next study, we used an Aeroneb Pro® nebulizer selected according to its safe properties with ventilator which was evaluated in a bench study. Any cytotoxicity was observed with high doses of teicoplanin and nebulization did not affect its pharmacological properties. In mechanically ventilated piglets, teicoplanin was administered efficiently by nebulization wih an aerosol delivery of 18.1% [16.3-27.0]. Pharmacokinetic parameters are particularly consistent with this time-dependent antibiotic and emphasize the potential of airways delivery of teicoplanin. In conclusion, nebulization of teicoplanin adds a further challenge to the development of aerosol therapy of antibiotics in VAP.
36

Implantação de protocolo de prevenção da pneumonia associada à ventilação mecânica : impacto do cuidado não farmacológico

Vieira, Débora Feijó Villas Boas January 2009 (has links)
Contextualização: Na última década, houve um grande crescimento de ações de melhoria da qualidade assistencial e de promoção da segurança do paciente, com objetivo de diminuir a ocorrência de desfechos preveníveis, como a pneumonia associada à ventilação mecânica (PAVM). Embora existam várias diretrizes clínicas, ainda não há evidências suficientes para um consenso quanto aos cuidados não farmacológicos de prevenção (CNFP) a serem implantados e sua contribuição na redução da PAVM. Objetivos: Avaliar o impacto da implantação de CNFP na ocorrência da PAVM. Métodos: O estudo foi realizado com pacientes adultos, submetidos à ventilação mecânica (VM) por mais de 48 horas, internados em centro de tratamento intensivo clínico e cirúrgico, de 34 leitos. No primeiro artigo, é descrito um quase experimento com controles históricos, realizado no período de setembro de 2004 (pré-intervenção -20 meses) a dezembro 2007 (pós-intervenção – 20 meses). Constou do experimento a implantação do protocolo de prevenção da PAVM, com cuidados não farmacológicos. No segundo artigo, é descrito um estudo de coorte prospectiva de pacientes submetidos à VM no período de junho de 2006 a julho de 2007. Entre as onze medidas preventivas que fazem parte da rotina de cuidados, foram escolhidas seis para serem examinadas na rotina assistencial de pacientes submetidos à VM: manutenção da cabeceira elevada (HOB) de 30º a 45º; manutenção do circuito de VM (CVM) sem condensação e sujidade; manutenção de trocadores de umidade e calor (HME); monitorização da pressão do balonete (PB) do tubo endotraqueal entre 18 mmHg a 25 mmHg; realização da higiene oral (HO) e realização fisioterapia respiratória (FR). Estabeleceu-se um ponto de corte de 80% para adesão aos cuidados de prevenção. Considerou-se o CNFP como adequado quando, durante a internação, o paciente foi observado em frequência, igual ou maior de 80%. Resultados: No primeiro estudo, foram diagnosticados 367 episódios de PAVM durante os 40 meses, em um total de 20285 dias de ventilação mecânica. A taxa de PAVM baixou em 28,7%, ou seja, de 20,6 casos por 1.000 dias de ventilação no período pré-intervenção para 16 casos por 1.000 dias de ventilação nos 20 meses seguintes à intervenção (P<0,001). Na análise de regressão segmentada verificou-se uma redução abruta de nível significativa do desfecho (t = -2,506; p= 0,017), mas não foi observado uma redução de tendência significativa do desfecho (t= -1,670; p= 0,104). No segundo estudo, a adesão aos seis CNFP foi aferida em 5.781 observações, em 541 internações de pacientes submetidos à ventilação mecânica, com 111 casos de PAVM. Nas internações em que os pacientes receberam cuidados adequados de prevenção, houve redução na ocorrência de PAVM de 61% para a FR (OR=0,39; IC95%= 0,18 a 0,84); 43% para a HOB (OR=0,57; IC95%= 0,31 a 0,99). Houve interação entre HO e PB, com uma redução da razão de chances de 56% para HO (OR=0,44; IC95%= 0,24 a 0,82) e 58% para PB (OR=0,42; IC95%= 0,21 a 0,85). Na ausência de um desses dois cuidados, o outro presente passa a ser fator de risco. Estimouse a fração de risco atribuível para não realização de FR, HO, monitorização PB e manutenção da HOB em frequência adequada, implicando a ocorrência de, respectivamente, 49% (IC95%= 13% a 65%), 29% (IC95%= 9% a 39%), 32% (IC95%= 8% a 44%) e 9% (IC95%= 0% a 13%) das PAVM. Conclusão: Os cuidados de prevenção da PAVM implantados mostraram-se medidas tecnologicamente simples, exequíveis em qualquer realidade e de baixo custo, possibilitando redução no desenvolvimento de PAVM e aumento na segurança do paciente. / Context: In the past decade there has been a large increase in the number of measures aimed at improving service quality and promoting patient safety. Most of these measures have been aimed at reducing the incidence of preventable iatrogenic morbidities such as ventilator-associated pneumonia (VAP). While related clinical guidelines do exist, there is still little evidence to indicate which of the many non-pharmacological preventive care (NPPC) measures provide the best protection against VAP. Objectives: To evaluate the impact of NPPC interventions on the incidence of VAP. Methods: The population represented in this study are adult, intensive care patients, admitted without pneumonia, which required mechanical ventilation (MV) for at least 48 hours. The 34 bed intensive care center clinic and surgical is part of a public, university hospital in Porto Alegre, Brazil. The first article describes a quasi-experimental study done during the 40 months between September, 2004 and December, 2007. Halfway through this period a non-pharmacological, VAP prevention protocol was introduced to the routine care intubated patients. As such the control group are those patient treated prior to introduction of the protocol and the experimental group, those patients treated after its introduction. The second article describes a prospective study of cohort of patients requiring mechanical ventilation between June, 2006 and July 2007. Of the 11 NPPC interventions that make up the protocol, 6 were selected for this study: maintaining the head-of-bed elevation between 30º and 45º (HOB), maintaining the mechanical ventilation circuit (MVC) clean and dry, maintaining the heat moisture exchange (HME) equipment; maintaining endotracheal tube cuff pressure (CP) between 18 and 25 mmHg, realizing oral hygiene (OH) and doing respiratory physiotherapy (RP). These interventions were audited, for each patient during their entire length of stay, to measure compliance with the protocol. For each non-pharmacological preventive intervention, any patient receiving ≥8O% of the recommended frequency of care was considered to have received that intervention. Results: During a total of 20285 days of MV, 367 cases of VAP were diagnosed. The incidence of VAP fell 28.7% (p<0.001), between the 20 month pre-intervention period (20.6 cases/1.000 MV days) and the 20 month post-intervention periods (16 cases/1.000 MV days). In the analysis of segmented regression there was a significant abrupt reduction in the level of outcome (t = - 2.506; p=0.017), but reduction of tendency of the outcome was not significant (t= - 1.670; p= 0.104). In the second study compliance with the 6 non-pharmacological preventive interventions was measure by means of 5.781 observations in 541 patients of whom 111 developed VAP. Patients that received ≥8O% of the recommended frequency of a specific intervention exhibited a reduction in the risk of developing VAP: 61% for RP (OR= 0.39; CI95%= 0.18 to 0.84); 43% for HOB (OR= 0.57; CI95%= 0.31 to 0.99); 56% for OH (OR= 0.44; CI95%= 0.24 to 0.82) and 58% for CP (OR= 0.42; CI95%= 0.21 to 0.85). OH and CP maintenance are interdependent. In the absence of the other intervention each goes from being protective to being a risk factor. The VAP risk attributable to non-compliance in each of RP, OH, CP and HOB is estimated to be: 49% (CI95%= 13% to 65%), 29% (CI95%= 9% to 39%), 32% (CI95%= 8% to 44%) and 9% (CI95%= 0% to 13%) respectively. Conclusion: NPPC interventions are technologically simple, low cost that, in combination, provide a patient security and substantial level of protection against VAP.
37

Fatores de risco para infecções hospitalares em crianças críticas / Risk factors for nosocomial infections in critical children

Mirza Rocha Figueiredo 25 April 2007 (has links)
O objetivo desta tese foi avaliar a influências da exposição a diversos fatores de risco e ocorrência de infecção hospitalar (IH) e examinar fatores de risco relacionados às pneumonias associadas ao uso de ventilador mecânico (PAV) em crianças críticas. Usamos os métodos de estudo prospectivo envolvendo uma coorte de 268 crianças menores de três anos, realizado em unidade de pacientes graves, de janeiro de 1997 e setembro de 2000. Aplicou-se técnica de regressão de Poisson para estimar razões de risco e estratégia de abordagem hierárquica para identificar fatores de risco associados à IH. Apenas para 179 crianças críticas que usaram ventilador mecânico, aplicou-se a regressão de Cox para estimar razões de risco e identificar fatores de risco associados à PAV. Os resultados apresentaram 74 infecções hospitalares diagnosticadas no total, com taxa de incidência de 48,1 IH por 1000 pacientes-dia. Foi determinante para ocorrência de infecção hospitalar, idade superior a dois anos (Razão de Risco) [RR]: 2,66; intervalo de confiança [IC]: 95%: 1,46-4,58), uso de sonda vesical (RR: 2,92; IC 95%: 1,47-5,80), uso de nutrição parenteral (RR: 1,90; IC 95%: 1,15-3,13), realização de broncoscopia (RR: 1,84; IC 95%: 1,03-3,27), tempo de exposição ao cateter vascular central (RR: 2,36; IC 95%: 1,18-4,71) e ao ventilador mecânico (RR: 1,72; IC 95%: 0,94-3,15). Observou-se PAV em 29 crianças (16,3%), com taxa de incidência de 29,3 casos por 1000 dias de ventilação mecânica (IC 95%: 20,34-42,11), dos quais 50% dos eventos ocorreram até o quinto dia de ventilação. A taxa de risco diária aumentou até um máximo de 2,3%, observada no 7 dia de ventilação, e reduziu a partir daí. Foram fatores de risco para PAV na análise multivariada hierarquizada, idade acima de 1 ano (RR: 3,49; IC 95%; 1,64-7,45), cirurgia do aparelho digestivo (RR: 5,05; IC 95%; 2,17-11,78) e nutrição parenteral (RR: 2,68; IC 95%: 1,24-5,8). /exposição a antibióticos antes da internação conferiu proteção (RR: 0,29; IC 95%: 0,13-0,66). Concluímos que os resultados encontrados neste estudo indicam que a influência do tempo de exposição é determinante para a ocorrência de infecções hospitalares e está associado aos processos de cuidados do paciente crítico. Políticas institucionais direcionadas ao controles e prevenção das IH devem fazer de estratégias fundamentais para a qualidade da assistência e segurança do paciente internado. Vigilância de Saúde Pública e componentes longitudinais de estudo de fatores de risco para infecções hospitalares e para pneumonias associadas ao ventilador podem ajudar avaliar prognósticos e planejar e testar medidas preventivas, concentrando-se esforços na primeira semana de ventilação. / The objective of this thesis is evaluate the influence of exposure to some risk factors and the occurrence of nosocomial infections (NI) and to examine risk factors for ventilator-associated pneumonia (VAP) in critically ill children. We use the prospective study was carried out on 268 children less than three years old, at a pediatric intensive care unit, from January 1997 to September 2000. Poisson regression and hierarchized multivariate analysis were performed to estimate incidence rate ratios and to identify risk factors associated to nosocomial infections. To 178 children only, who were ventilated, Cox regression was performed to estimate hazards ration and to identify risk factors for VAP. Our results were 74 nosocomial infections were diagnosed, and the overall incidence of NI cases was 48.1 per 1000 patient-days. The final model showed as predictors of nosocomial infections were age over two (incidence rate ratio [IRR]: 2.66, confidence interval [CI] 95%:1.46- 4.58), urinary tract catheter (IRR: 2.92; CI 95%: 1.47-5.8), parenteral nutrition use (IRR: 1.90; CI 95%: 1.15-3.13), bronchoscope use (IRR: 1.84; CI 95%: 1.03-3.27), central catheters exposure time (IRR: 1,72; CI 95%: 0.94-3.15), 29 childrem (16.3%) developed VAP and the overall incidence was 29.3 per 1000 ventilator-days (OC 95%: 29.34-42.11); 50% of all cases had happened until day 5 of ventilator. The daily hazard risk increased to 2.2% at day 7, and decreased after that. Risk factors of VAP in hierarchized multivariate analysis were age over one (hazards ratio [HR]: 3.49; IC 95%: 1.64-7.45), digestive surgery (HR: 5.05; CI 95%: 2.17-11.78), parenteral nutrition (HR: 2.68; IC 95% 1.24-5.80). Exposure to antibiotics conferred protection (HR: 0.29; IC 95%: 0.13-0.65). Our conclusion is: the results suggest that the influence of the exposure time is determinant of nosocomial infections occurrence, and it is healthcare associated in critically ill patients. Institutional politics might be aimed at prevention and control activities, as strategy to promote healthcare quality and patient safety. Public health surveillance and longitudinal studies of risk factors for ventilator-associated pneumonias can help to assess prognosis, and devise and test preventive strategies, and efforts might be concentrated on the first week of ventilation assistance.
38

Implantação de protocolo de prevenção da pneumonia associada à ventilação mecânica : impacto do cuidado não farmacológico

Vieira, Débora Feijó Villas Boas January 2009 (has links)
Contextualização: Na última década, houve um grande crescimento de ações de melhoria da qualidade assistencial e de promoção da segurança do paciente, com objetivo de diminuir a ocorrência de desfechos preveníveis, como a pneumonia associada à ventilação mecânica (PAVM). Embora existam várias diretrizes clínicas, ainda não há evidências suficientes para um consenso quanto aos cuidados não farmacológicos de prevenção (CNFP) a serem implantados e sua contribuição na redução da PAVM. Objetivos: Avaliar o impacto da implantação de CNFP na ocorrência da PAVM. Métodos: O estudo foi realizado com pacientes adultos, submetidos à ventilação mecânica (VM) por mais de 48 horas, internados em centro de tratamento intensivo clínico e cirúrgico, de 34 leitos. No primeiro artigo, é descrito um quase experimento com controles históricos, realizado no período de setembro de 2004 (pré-intervenção -20 meses) a dezembro 2007 (pós-intervenção – 20 meses). Constou do experimento a implantação do protocolo de prevenção da PAVM, com cuidados não farmacológicos. No segundo artigo, é descrito um estudo de coorte prospectiva de pacientes submetidos à VM no período de junho de 2006 a julho de 2007. Entre as onze medidas preventivas que fazem parte da rotina de cuidados, foram escolhidas seis para serem examinadas na rotina assistencial de pacientes submetidos à VM: manutenção da cabeceira elevada (HOB) de 30º a 45º; manutenção do circuito de VM (CVM) sem condensação e sujidade; manutenção de trocadores de umidade e calor (HME); monitorização da pressão do balonete (PB) do tubo endotraqueal entre 18 mmHg a 25 mmHg; realização da higiene oral (HO) e realização fisioterapia respiratória (FR). Estabeleceu-se um ponto de corte de 80% para adesão aos cuidados de prevenção. Considerou-se o CNFP como adequado quando, durante a internação, o paciente foi observado em frequência, igual ou maior de 80%. Resultados: No primeiro estudo, foram diagnosticados 367 episódios de PAVM durante os 40 meses, em um total de 20285 dias de ventilação mecânica. A taxa de PAVM baixou em 28,7%, ou seja, de 20,6 casos por 1.000 dias de ventilação no período pré-intervenção para 16 casos por 1.000 dias de ventilação nos 20 meses seguintes à intervenção (P<0,001). Na análise de regressão segmentada verificou-se uma redução abruta de nível significativa do desfecho (t = -2,506; p= 0,017), mas não foi observado uma redução de tendência significativa do desfecho (t= -1,670; p= 0,104). No segundo estudo, a adesão aos seis CNFP foi aferida em 5.781 observações, em 541 internações de pacientes submetidos à ventilação mecânica, com 111 casos de PAVM. Nas internações em que os pacientes receberam cuidados adequados de prevenção, houve redução na ocorrência de PAVM de 61% para a FR (OR=0,39; IC95%= 0,18 a 0,84); 43% para a HOB (OR=0,57; IC95%= 0,31 a 0,99). Houve interação entre HO e PB, com uma redução da razão de chances de 56% para HO (OR=0,44; IC95%= 0,24 a 0,82) e 58% para PB (OR=0,42; IC95%= 0,21 a 0,85). Na ausência de um desses dois cuidados, o outro presente passa a ser fator de risco. Estimouse a fração de risco atribuível para não realização de FR, HO, monitorização PB e manutenção da HOB em frequência adequada, implicando a ocorrência de, respectivamente, 49% (IC95%= 13% a 65%), 29% (IC95%= 9% a 39%), 32% (IC95%= 8% a 44%) e 9% (IC95%= 0% a 13%) das PAVM. Conclusão: Os cuidados de prevenção da PAVM implantados mostraram-se medidas tecnologicamente simples, exequíveis em qualquer realidade e de baixo custo, possibilitando redução no desenvolvimento de PAVM e aumento na segurança do paciente. / Context: In the past decade there has been a large increase in the number of measures aimed at improving service quality and promoting patient safety. Most of these measures have been aimed at reducing the incidence of preventable iatrogenic morbidities such as ventilator-associated pneumonia (VAP). While related clinical guidelines do exist, there is still little evidence to indicate which of the many non-pharmacological preventive care (NPPC) measures provide the best protection against VAP. Objectives: To evaluate the impact of NPPC interventions on the incidence of VAP. Methods: The population represented in this study are adult, intensive care patients, admitted without pneumonia, which required mechanical ventilation (MV) for at least 48 hours. The 34 bed intensive care center clinic and surgical is part of a public, university hospital in Porto Alegre, Brazil. The first article describes a quasi-experimental study done during the 40 months between September, 2004 and December, 2007. Halfway through this period a non-pharmacological, VAP prevention protocol was introduced to the routine care intubated patients. As such the control group are those patient treated prior to introduction of the protocol and the experimental group, those patients treated after its introduction. The second article describes a prospective study of cohort of patients requiring mechanical ventilation between June, 2006 and July 2007. Of the 11 NPPC interventions that make up the protocol, 6 were selected for this study: maintaining the head-of-bed elevation between 30º and 45º (HOB), maintaining the mechanical ventilation circuit (MVC) clean and dry, maintaining the heat moisture exchange (HME) equipment; maintaining endotracheal tube cuff pressure (CP) between 18 and 25 mmHg, realizing oral hygiene (OH) and doing respiratory physiotherapy (RP). These interventions were audited, for each patient during their entire length of stay, to measure compliance with the protocol. For each non-pharmacological preventive intervention, any patient receiving ≥8O% of the recommended frequency of care was considered to have received that intervention. Results: During a total of 20285 days of MV, 367 cases of VAP were diagnosed. The incidence of VAP fell 28.7% (p<0.001), between the 20 month pre-intervention period (20.6 cases/1.000 MV days) and the 20 month post-intervention periods (16 cases/1.000 MV days). In the analysis of segmented regression there was a significant abrupt reduction in the level of outcome (t = - 2.506; p=0.017), but reduction of tendency of the outcome was not significant (t= - 1.670; p= 0.104). In the second study compliance with the 6 non-pharmacological preventive interventions was measure by means of 5.781 observations in 541 patients of whom 111 developed VAP. Patients that received ≥8O% of the recommended frequency of a specific intervention exhibited a reduction in the risk of developing VAP: 61% for RP (OR= 0.39; CI95%= 0.18 to 0.84); 43% for HOB (OR= 0.57; CI95%= 0.31 to 0.99); 56% for OH (OR= 0.44; CI95%= 0.24 to 0.82) and 58% for CP (OR= 0.42; CI95%= 0.21 to 0.85). OH and CP maintenance are interdependent. In the absence of the other intervention each goes from being protective to being a risk factor. The VAP risk attributable to non-compliance in each of RP, OH, CP and HOB is estimated to be: 49% (CI95%= 13% to 65%), 29% (CI95%= 9% to 39%), 32% (CI95%= 8% to 44%) and 9% (CI95%= 0% to 13%) respectively. Conclusion: NPPC interventions are technologically simple, low cost that, in combination, provide a patient security and substantial level of protection against VAP.
39

Uma interven??o educativa para profissionais de sa?de na preven??o de pneumonia associada ? ventila??o mec?nica / An educative intervention for the health-care workers to prevent ventilator-associated pneumonia

Melo, Cristiane Ribeiro de 29 May 2008 (has links)
Made available in DSpace on 2014-12-17T14:46:36Z (GMT). No. of bitstreams: 1 CristianeRM.pdf: 5245197 bytes, checksum: e2a591b692b29f0a98a345fa8cdc01ad (MD5) Previous issue date: 2008-05-29 / Quasi-experimental study, prospective with quantitative approach, performed at the Hospital do Cora??o in Natal, aimed at verified the existence of difference between the care given by health professionals to the patients under mechanical ventilation (MV) in the Intensive Care Unit, before and after an educative intervention. The population was of 31 professionals, with data collected between november 05 of 2007 to march 27 of 2008. The results show a yong population, female gender, middle level of education, nursing technique, working between 05 and 09 years on nursing profession, and 01 to 04 years on Intensive Care Unit; almost all, never had an kind of training over prevent pneumonia associated to mechanical ventilation; from those that had training, occur on the work place with duration from 12 to 24 hours. About endotracheal intubation, the cuff was tested with a sterilized syringe had a positive change after a educative intervention, increased from 75,0% to 100,0%; the sterile guide was used on 75,0% before and 100,0% after an educative intervention. Regarding endotracheal suction procedure, was not informed to the patient on 72,7% before, however was informed on 56,7% after; the hands was not previously washed 68,5% before, however was 63,3% after the procedure; mask was used on 74,2 % opportunities before and 76,7% after; the aspiration catheter had adequated size on 98,9% observation before and 100,0% after; the gaze was sterilized on 95,7% before and 100,0% after; the ventilator was connected to the patient during the aspiration intervals on 94,4% observation before and 100,0% after; the ambu bag was clean and protected on 76,1% before and 85,7% after; the aspiration catheter was discarded after be used on 98,9% before and 100,0% after; FIO2 was turned to the begging value on 32,9% observation before and 12,0% after; before the procedure 71,9% professions washed their hands and 73,3% after; before, notes of aspiration results were performed on 70,8% observation and 86,7% after. Regarding devices used on respiratory tract, aspirator flasks were not swapped on 84,6% observations before and 71,0% after; daily l?tex extention change was not performed on 93,6% observation before and 87,1% after; the ambu bag change was not performed on 50,0% observation before even if was duty or unprotected and on 75,8% opportunities was changed, after; nebulization was not prepared with sterile fluids or manipulated aseptically on 65,2% observation before, perhaps was on 71,7% after; before nebulizers were not changed on 65,2% observations, perhaps were on 60,9% after. Concerning ventilator breathing circuits, condense fluids cumulated on circuits were removed on 55,0% opportunities before, and 64,0% after; moisturizer was not filled with sterile water when already had small amount of liquid inside on 78,4% observations before, and 90,2% after; MV circuits were changed on 97,0% observations on presence of visible duty or when presents some kind of failure, before and 98,4% after. About body position, on 51,3% observations the decubitus position change were done before and 78,2% after; fowler position was maitened on 95,5% observations before and 98,2% after; Regarding respiratory physiotherapy, enteral diet was not interrupted before respiratory physiotherapy on 94,9% before and 90,0% after; respiratory physiotherapy devices were not disinfected or sterile on 69,6% observations before but they re on 60,0% after; before the cateter was not tested before introduction enteral diet or medications on 100,0% but after was done on 15,2%. About enteral feeding, intestine motility and measure of stomach contents were not done on 100,0% observations before, but was 15,2% after. We conclude that 05 of 07 valuated procedures in relation to MV, had a significant improvement on quality of care given after educative intervention, when compared before intervention / Estudo quase-experimental, com abordagem quantitativa, delineamento tempo-s?rie e dados prospectivos, realizado no Hospital do Cora??o de Natal, objetivando verificar a exist?ncia de diferen?a entre a assist?ncia prestada pelos profissionais de sa?de aos pacientes sob ventila??o mec?nica (VM) internados na UTI, antes e ap?s uma interven??o educativa. A popula??o fo de 31 profissionais, com dados coletados entre 05 de novembro de 2007 e 27 de mar?o de 2008. Os resultados mostram uma popula??o jovem, entre 20 e 30 anos de idade, do sexo feminino, ensino n?vel m?dio completo, na maioria, t?cnicos de enfermagem, trabalhando entre 05 e 09 anos na profiss?o, e 01 e 04 anos em UTI; a maioria nunca realizou treinamento acerca da preven??o de PAV; dos que realizaram, participaram em eventos da institui??o com dura??o entre 12 e 24 horas. Quanto ? intuba??o endotraqueal, o teste do cuff com seringa est?ril sofreu modifica??o positiva, ap?s a interven??o educativa, aumentando de 75,0% para 100,0%; o fio guia est?ril foi usado em 75,0% das ocasi?es antes e em 100,0% ap?s. Sobre aaspira??o endotraqueal, n?o foi explicado ao paciente sobre esse procedimento em 72,7% das situa??es antes, mas foi em 56,7% das vezes ap?s; a higieniza??o das m?os n?o foi realizada previamente em 68,5% das vezes antes, mas foi em 63,3% ap?s; a m?scara foi utilizada em 74,2% das oportunidades antes e em 76,7% ap?s; o cateter de aspira??o tinha o tamanho adequado em 98,9% das observa??es antes e em 100,0% ap?s; a gaze usada estava est?ril em 95,7% antes e em 100,0% ap?s; o ventilador foi conectado ao paciente durante os intervalos da aspira??o em 94,4% das oportunidades antes e em 100,0% ap?s; o ambu estava limpo e protegido em 76,1% das situa??es antes e em 85,7% ap?s; o cateter de aspira??o foi descartado ap?s o uso em 98,9% das oportunidades antes e em 100,0% ap?s; a extens?o de l?tex foi limpa em 86,5% das observa??es antes e em 93,3% ap?s; a FIO2 foi retornada ao valor inicial em 32,9% das vezes antes e em 12,0% ap?s; a higieniza??o das m?os ao t?rmino do procedimento foi feita em 71,9% das situa??es antes e em 73,3% ap?s; as anota??es referentes ? aspira??o foram feitas em 70,8% das observa??es antes e em 86,7% ap?s. Quanto aos dispositivos, a troca di?ria dos frascos aspiradores n?o foi obedecida em 84,6% das oportunidades antes e em 71,0% ap?s; a troca di?ria da extens?o de l?tex n?o foi realizada em 93,6% das vezes antes e em 87,1% ap?s; o ambu n?o foi trocado em 50,0% das observa??es, embora estivesse sujo e/ou desprotegido antes, mas em 75,8% das oportunidades esse dispositivo foi trocado ap?s; a nebuliza??o n?o foi preparada com flu?dos n?o est?reis e/ou manipulada assepticamente em 65,2% das ocasi?es antes; entretanto em 71,7% das vezes foram realizados ap?s; os nebulizadores n?o foram trocados em 65,2% das situa??es antes, mas foram em 60,9% ap?s. Acerca dos circuitos do VM, o condensado acumulado nos circuitos foi descartado em 55,0% das vezes antes e em 64,0% ap?s; o preenchimento do umidificador com ?gua, n?o foi feito em 78,4% das vezes em que possu?a l?quidos remanescentes antes e em 90,2% ap?s; os circuitos do VM foram trocados em 97,0% das oportunidades em que apresentavam sujidade vis?vel ou estavam defeituosos antes e em 98,4% ap?s. Quanto ? mudan?a de dec?bito, em 51,3% das vezes antes foi realizada e em 78,2% ap?s; a cabeceira do leito do paciente foi mantida elevada em 95,5% das observa??es antes e em 98,2% ap?s. Sobre a fisioterapia, a dieta enteral n?o foi interrompida antes das manobras fisioter?picas em 94,9% das situa??es antes e em 90,0% ap?s; os materiais usados durante a fisioterapia n?o estavam desinfetados e/ou est?reis em 69,6% das observa??es antes, mas estavam em 60,0% ap?s. Quanto ? nutri??o enteral, o teste da sonda antes de iniciar a dieta enteral ou de administrar medicamentos n?o foi realizado em nenhuma das oportunidades antes, entretanto foi em 15,2% ap?s; a motilidade intestinal e aferi??o do conte?do (residual) g?strico n?o foram verificadas em nenhuma das observa??es, mas foi em 15,2%, ap?s. Conclu?mos que, em 05 dos 07 procedimentos avaliados em rela??o ? VM, houve melhora significativa na qualidade da assist?ncia prestada quando comparados ao momento anterior ? interven??o educativa
40

Ocorrência de Acinetobacter baumannii resistente aos carbapenêmicos em pneumonias associadas a ventilação mecânica em uma unidade de terapia intensiva de adultos mista de um hospital universitário brasileiro: fatores de risco e prognóstico

Guimarães, Munick Paula 22 February 2011 (has links)
Mestre em Imunologia e Parasitologia Aplicadas / Acinetobacter baumannii emergiu como um dos patógenos hospitalares mais importantes em UTIs nos últimos anos devido principalmente a sua maior resistência aos antimicrobianos. Os fatores de risco associados a PAV por A. baumannii variam de acordo com a unidade e há controvérsias sobre sua virulência e mortalidade atribuída. O objetivo deste estudo foi avaliar os fatores de risco e a mortalidade hospitalar no prazo de 30 dias em pacientes com PAV por A. baumannii bem como diferenças quanto a essa mortalidade hospitalar e o uso de terapêutica adequada ou inadequada em pacientes com PAV por A. baumannii multirresistente versus não-multirresistente. Um estudo de pacientes com PAV por A. baumannii (casos) versus pacientes em uso de ventilação mecânica sem PAV (controles) quanto aos fatores de risco e evolução, foi realizado na UTI de adultos, mista, do Hospital de Clínicas da Universidade Federal de Uberlândia no período de 09/2008 a 08/2009. O hospital de Clínicas é de ensino e assistência terciária e sua UTI tem 15 leitos. O diagnóstico de PAV foi por critérios clínicos, radiológicos e microbiológicos com contagem &#8805;106 UFC/mL. A identificação das amostras foi feito com o Kit BD BBL Crystal Nonenteric e o antibiograma por difusão de disco seguindo as orientações do CLSI. Os resultados foram submetidos a análise univariada e multivariada e a investigação foi aprovada pelo Comitê de Ética e Pesquisa da UFU. As PAVs foram usualmente tardias (90,0%), com A. baumannii como o segundo agente etiológico mais frequente (25,7%) seguindo a Pseudomonas aeruginosa (32,5%). Os fatores de riscos significantes associados à infecções por este microrganismo na análise univariada foram: gênero masculino (p= 0,0144; OR= 4,814), diagnóstico clínico na admissão (p= 0,0129. OR=0,239), diagnóstico cirúrgico na admissão (p= 0,0321, OR= 4.607) ventilação mecânica &#8805; 7 dias (p= 0,0315, OR= 5,939), tempo de internação na UTI &#8805; 20 dias (p=0,0002, OR= 9,578), uso prévio de antibióticos (p=0,0006, OR=6,333) e uso prévio de carbapenêmicos (p< 0,0001, OR=10,250), persistindo como fatores independentes na análise multivariada uso prévio de carbapenêmicos (p=0,0249, OR= 6,280) e tempo de internação na UTI &#8805; 20 dias (p=0,0148, OR= 7,427). A. baumannii foi responsável por cerca de um quarto das PAVs, com o uso prévio de carbapenêmicos e internação na UTI &#8805; 20 dias comportandose como fatores de risco independentes. Embora a mortalidade hospitalar nas PAVs por este microrganismo não fosse diferente do grupo controle, elas foram causadas na sua maioria (87,5%) por amostras multiresistentes em pacientes em uso de terapêutica antibiótica empírica incorreta (87,5%).

Page generated in 0.3534 seconds