• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 57
  • 29
  • 28
  • 14
  • 12
  • 10
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito da natação sobre o músculo reto do abdome do rato: estudo morfológico e histoquímico

Rosa, Maria José Alvarez [UNIFESP] 30 January 2008 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-30. Added 1 bitstream(s) on 2015-08-11T03:25:42Z : No. of bitstreams: 1 Publico-10687.pdf: 1877074 bytes, checksum: a4c8dc96819854b6fe9209dc009690ba (MD5) / Tese em forma de artigo. Objetivo: Investigamos o efeito de dois protocolos de natação nas características morfológicas, contráteis e metabólicas dos diferentes tipos de fibras do músculo reto do abdome de rato. Métodos: Os ratos foram divididos em 3 grupos (N = 5 cada): a) grupo treinado 1h por dia (1h/dia), 2x por semana (2x/sem); b) grupo treinado 1h/dia, 5x por semana (5x/sem), ambos durante 9 semanas consecutivas; c) grupo controle: sedentário. Foram avaliados os pesos corporais, os diâmetros das fibras, pelo método de coloração HE, e a distribuição dos tipos de fibras pelas as propriedades metabólicas identificadas pela reação de NADH redutase e reação de ATP-ase miofibrilar. Resultados: O peso corporal aumentou no grupo treinado 2x/sem e diminuiu no grupo treinado 5x/sem em relação ao grupo controle. O diâmetro das fibras aumentou de 45,4 μm no grupo controle para 56,6 μm e 54,4 μm no grupo treinado 2x/sem e 5x/sem, respectivamente. Também foram observadas pequenas fibras angulosas atróficas. O exercício aeróbio remodelou a distribuição das fibras, aumentando a freqüência de fibras oxidativas lentas (SO) e oxidativas-glicolíticas rápidas (FOG) e diminuindo a freqüência de fibras glicolíticas (FG). Em resumo, a freqüência das fibras SO aumentou, enquanto a freqüência das FOG + FG diminuíram nos ratos treinados em comparação aos sedentários. Conclusões: Estes resultados mostram que os dois protocolos de exercício da natação aumentam prioritariamente o metabolismo aeróbio das fibras de contração lenta e intermediária, além de provocar grau variável de mudanças na morfologia das fibras. / TEDE
22

O Magic Circle aumenta a atividade eletromiográfica abdominal e a pressão intravaginal no exercício The Hundred do Método Pilates?

Paulitsch, Alessandra Fayh January 2013 (has links)
O Método Pilates parte do princípio da centralização, no qual todo movimento começa e é sustentado no centro do corpo, chamado de centro de força, ou, ainda, de powerhouse. Com a finalidade de ajudar o praticante do método a localizar o powerhouse, aumentar o controle e o recrutamento dos músculos que o compõem, Joseph Pilates criou o acessório Magic Circle, o qual consiste num aro flexível com aproximadamente 40 cm de diâmetro, utilizado, entre outras finalidades, para aumentar a atividade dos músculos abdominais em alguns exercícios do Método Pilates. O objetivo deste trabalho foi comparar a atividade eletromiográfica abdominal, bem como analisar a pressão intravaginal, nos exercícios The Hundred e The Hundred modificado, executados com e sem o acessório Magic Circle. Foram analisados, simultaneamente, o sinal eletromiográfico de superfície dos músculos reto abdominal, oblíquo externo, oblíquo interno e adutor longo, e a pressão intravaginal durante a execução dos exercícios The Hundred e The Hundred modificado com e sem a utilização do Magic Circle. Verificou-se uma maior atividade nos músculos abdominais apenas quando o Magic Circle foi utilizado em situações de instabilidade, enquanto a pressão intravaginal não foi afetada pelo uso do acessório. O Magic Circle pode ser recomendado para uma maior ativação da musculatura abdominal nas situações de maior instabilidade mecânica e não é recomendado quando se busca uma maior pressão intravaginal. / The Pilates method is based on the centering principle, in which every movement starts and is supported by the center of the body, called strong core or powerhouse. In order to help the practitioner locate the powerhouse and increase the control and recruitment of its muscles, Joseph Pilates created the accessory Magic Circle, which consists of a flexible ring, approximately 40cm wide, used, among other purposes, to increase abdominal muscle activity in some exercises of the Pilates Method. The aim of this study was to compare the abdominal electromiographic activity, as well as to analyze intra-vaginal pressure in the exercises The Hundred and The Hundred modified, performed with and without the accessory Magic Circle. The study simultaneously analyzed the electomiographic signal on the surface of the rectus abdominis, external oblique, internal oblique, aductor longus, as well as intra-vaginal pressure during the performance of the exercises The Hundred and The Hundred modified with and without the use of the Magic Circle. There was higher activity on the abdominal muscles only when the Magic Circle was used in instability situations, while the intra-vaginal pressure was not affected by the use of the accessory. The Magic Circle can be recommended for higher activation of the abdominal muscles in mechanical instability situations and is not recommended when pursuing higher intravaginal pressure.
23

Função dos músculos do assoalho pélvico : comparação entre mulheres praticantes do método Pilates e sedentárias

Barbosa, Lia Janaina Ferla January 2014 (has links)
Pesquisas relacionadas os músculos do assoalho pélvico (MAP) tem ganhado espaço na última década principalmente quando se refere a alterações na sua função. A maioria das pesquisas encontradas na literatura diz respeito às disfunções dos MAP. É importante conhecer formas de condicionamento dessa musculatura que possa evitar a perda de função, seja por falta de exercícios os por alterações decorrentes do processo de envelhecimento. Sabe-se que em mulheres com disfunção o treinamento dos músculos do assoalho pélvico (TMAP) tem um efeito positivo na melhora da função desse grupo muscular o qual comumente é treinado isoladamente. Porém as formas de melhorar o condicionamento independente de um quadro de disfunção ainda são pouco investigadas, visto que mulheres não ingressam em um TMAP de forma preventiva. Já há registros de exercícios que podem gerar impacto negativo sobre a função dessa musculatura, como corrida e jump, mas não sobre exercícios que possam melhorar a função. A existência de um sinergismo entre os músculos profundos do tronco, em especial do transverso abdominal (TrA), e do assoalho pélvico (AP) é tema de estudos recentes e uma estratégia de prevenção seria a prática de exercício físico regular, que enfatize a coativação dos músculos abdominais e do AP. Assim, esta dissertação teve como foco de estudo identificar a presença ou não de sinergismo abdomino-pélvico em mulheres hígidas e também identificar se a função dos MAP de mulheres que praticam o Método Pilates diferem de sedentárias. O Método Pilates tem por objetivo melhorar o condicionamento de todos os grupos musculares que compõem o powerhouse, incluindo, portanto, TrA e os MAP. O primeiro estudo foi uma revisão sistemática das pesquisas que buscou identificar a presença de sinergismo em mulheres sem disfunções do assoalho pélvico. Tal revisão seguiu as recomendações propostas pela Colaboração Cochrane e a busca na literatura incluiu as bases MEDLINE, Cochrane CENTRAL e EMBASE, além de busca manual, do início das bases até agosto de 2013. Foram incluídos estudos observacionais transversais, com mulheres hígidas que foram avaliadas quanto à presença de sinergismo abdomino-pélvico. Foram incluídos 10 artigos e todos demonstraram a existência de sinergismo entre os músculos abdominais e músculos do assoalho pélvico (MAP) em mulheres hígidas nas posturas supina, sentada e em ortostase. O conhecimento desse sinergismo pode favorecer a proposição de estratégias de tratamento e prevenção das disfunções dos MAP feminino. O segundo estudo que compôs esta dissertação teve por objetivo verificar se existe diferença na função dos MAP entre mulheres praticantes do Método Pilates e sedentárias. O estudo foi observacional e transversal, com uma amostragem composta por mulheres praticantes do Método Pilates (GMP) e sedentárias (GS). O nível de significância e o poder estatístico foram fixados em 5% e 80%, respectivamente, e o tamanho da amostra foi de no mínimo 24 indivíduos para cada grupo - Grupo Método Pilates (GMP) e Grupo Sedentárias (GS). Para avaliação da função dos MAP utilizou-se a perineometria e a Escala PERFECT e uma Ficha de Anamnese. Foi utilizada estatística inferencial, sendo o nível de significância adotado menor ou igual a 0,05. Foram avaliadas um total de 60 mulheres, sendo 30 do GMP e 30 do GS. Este estudo demonstrou não haver diferença significativa entre o GMP e o GS em nenhuma das variáveis analisadas. Conclui-se que mulheres praticantes do Método Pilates não diferem de mulheres sedentárias em relação à função dos MAP. / Searches related muscles of the pelvic floor (MAP) has gained ground over the last decade particularly when it comes to changes in its function. Most studies found in the literature with regard to disorders of MAP. It is important to know ways of conditioning these muscles which can prevent loss of function, either by lack of exercise for the changes resulting from the aging process. It is known that the dysfunction in women with pelvic floor training (PFMT) muscles have a positive effect on the improvement of the function of this muscle group which is commonly trained alone. But the ways to improve the fitness of an independent frame of dysfunction are still poorly investigated, since women do not enter into a TMAP preventively. Already there are reports of exercises that can have a negative impact on the function of these muscles, such as running and jump, but not about exercises that can improve function. The existence of a synergism between the deep trunk muscles, particularly the transversus abdominis (TrA), and pelvic floor (AP) is the subject of recent studies and a prevention strategy would be the practice of regular exercise that emphasizes coactivation abdominal muscles and the AP. Thus, this dissertation focused study to identify the presence or absence of abdominal-pelvic synergism in healthy women and to identify the function of the MAP of women who practice Pilates differ from sedentary. The Pilates method aims to improve the conditioning of all muscle groups that make up the powerhouse, including therefore TrA and MAP. The first study was a systematic review of research aimed at identifying the presence of synergism in women without pelvic floor dysfunction. This review followed the recommendations proposed by the Cochrane Collaboration and the literature search included the MEDLINE, EMBASE and Cochrane CENTRAL databases, and manual search, the start of the bases until August 2013 transversal observational studies were included, with healthy women who were evaluated for the presence of abdominal-pelvic synergism. 10 articles were included and all demonstrated the existence of synergism between the abdominal muscles and pelvic floor muscles (PFMs) in healthy women in the supine, sitting postures and standing positions. Knowledge of this synergism may favor the proposition of strategies for treatment and prevention of disorders of the female MAP. The second study that composed this dissertation aimed to verify whether there are differences in the function of MAP between practitioners of Pilates and sedentary women. The study was observational and cross-sectional, with a sample composed by practitioners of Pilates (GMP) and sedentary (GS) women. The significance level and statistical power were set at 5% and 80%, respectively, and the sample size was at least 24 subjects for each group - Group Pilates Method (GMP) and Sedentary Group (GS). To evaluate the role of MAP was used perineometry and Scale PERFECT and a sheet of Anamnesis. Inferential statistics were used, and the significance level less than or equal to 0.05. A total of 60 women, 30 and 30 of the GMP GS were evaluated. This study showed no significant difference between the GMP and the GS in any of the variables analyzed. It is concluded that women who practice Pilates Method not differ from sedentary women in relation to the function of MAP.
24

Análise eletromiográfica de exercícios abdominais realizados por mulheres no meio líquido

Figueiredo, Paulo André Poli de January 2004 (has links)
O objetivo deste trabalho foi verificar a atividade elétrica dos músculos oblíquo externo, reto femoral e das porções supra-umbilical e infra-umbilical do reto abdominal, durante a execução de determinados exercícios abdominais realizados no meio líquido. A amostra foi composta por 20 (vinte) mulheres adaptadas ao meio líquido, com idade entre 21 e 29 anos. A atividade elétrica foi coletada com eletrodos de superfície, sendo o sistema de coleta de dados previamente adaptado, evitando o contato com a água. O exercício de flexão de tronco até a posição sentada, realizado em seco, foi utilizado como referência, sendo o valor root mean square (RMS), da fase ascendente deste exercício, empregado para a normalização da amplitude do sinal coletado durante os demais exercícios. Flexões de tronco e de quadril foram realizadas no meio líquido, na posição horizontal, com o apoio de um tubo nos membros superiores e em um ritmo padrão, sendo dois destes exercícios também realizados em máxima velocidade. Foi utilizado ANOVA two ways, em cada músculo, pelos fatores exercícios e fase. Para melhor compreender a ativação em cada fase, utilizou-se ANOVA one way no valor da fase ascendente de cada músculo pelo fator exercício, assim como somente nos valores da fase descendente. Para verificar onde estavam as diferenças, utilizou-se o Post Hoc de Tukey. Os dados foram também normalizados no tempo, sendo apresentados gráficos da atividade eletromiográfica dos músculos durante todo o ciclo de cada exercício. Ao analisar os exercícios como um todo, constatou-se que os exercícios aquáticos em ritmo padrão possuem menor atividade que o de referência Ao analisar a fase ascendente dos exercícios aquáticos em ritmo padrão, o músculo reto abdominal em todos os exercícios, e o oblíquo externo nos exercícios sem apoio são tão eficiente quanto o exercício referência, mostrando que a instabilidade da posição horizontalizada e a resistência ao movimento compensam a diminuição do peso hidrostático. Já na fase descendente, além de menor atividade, o padrão da atividade muscular modifica nos exercícios aquáticos, possivelmente, mantendo uma atividade de estabilização, enquanto outro grupo muscular é responsável pelo movimento. A realização do exercício em máxima velocidade apresentou uma grande atividade eletromiográfica dos músculos abdominais no meio líquido e, para o reto femoral, a amplitude de movimento foi muito importante para sua ativação. Dessa forma, a flexão de tronco em máxima velocidade é um exercício de grande atividade abdominal e baixa atividade dos flexores de quadril. As características das forças externas ao corpo, nos exercícios abdominais realizados no meio líquido, proporcionam uma situação única de redução de peso hidrostático, resistência ao movimento, apoio relativo e tendência de rotação para atingir o equilíbrio estável.
25

O Magic Circle aumenta a atividade eletromiográfica abdominal e a pressão intravaginal no exercício The Hundred do Método Pilates?

Paulitsch, Alessandra Fayh January 2013 (has links)
O Método Pilates parte do princípio da centralização, no qual todo movimento começa e é sustentado no centro do corpo, chamado de centro de força, ou, ainda, de powerhouse. Com a finalidade de ajudar o praticante do método a localizar o powerhouse, aumentar o controle e o recrutamento dos músculos que o compõem, Joseph Pilates criou o acessório Magic Circle, o qual consiste num aro flexível com aproximadamente 40 cm de diâmetro, utilizado, entre outras finalidades, para aumentar a atividade dos músculos abdominais em alguns exercícios do Método Pilates. O objetivo deste trabalho foi comparar a atividade eletromiográfica abdominal, bem como analisar a pressão intravaginal, nos exercícios The Hundred e The Hundred modificado, executados com e sem o acessório Magic Circle. Foram analisados, simultaneamente, o sinal eletromiográfico de superfície dos músculos reto abdominal, oblíquo externo, oblíquo interno e adutor longo, e a pressão intravaginal durante a execução dos exercícios The Hundred e The Hundred modificado com e sem a utilização do Magic Circle. Verificou-se uma maior atividade nos músculos abdominais apenas quando o Magic Circle foi utilizado em situações de instabilidade, enquanto a pressão intravaginal não foi afetada pelo uso do acessório. O Magic Circle pode ser recomendado para uma maior ativação da musculatura abdominal nas situações de maior instabilidade mecânica e não é recomendado quando se busca uma maior pressão intravaginal. / The Pilates method is based on the centering principle, in which every movement starts and is supported by the center of the body, called strong core or powerhouse. In order to help the practitioner locate the powerhouse and increase the control and recruitment of its muscles, Joseph Pilates created the accessory Magic Circle, which consists of a flexible ring, approximately 40cm wide, used, among other purposes, to increase abdominal muscle activity in some exercises of the Pilates Method. The aim of this study was to compare the abdominal electromiographic activity, as well as to analyze intra-vaginal pressure in the exercises The Hundred and The Hundred modified, performed with and without the accessory Magic Circle. The study simultaneously analyzed the electomiographic signal on the surface of the rectus abdominis, external oblique, internal oblique, aductor longus, as well as intra-vaginal pressure during the performance of the exercises The Hundred and The Hundred modified with and without the use of the Magic Circle. There was higher activity on the abdominal muscles only when the Magic Circle was used in instability situations, while the intra-vaginal pressure was not affected by the use of the accessory. The Magic Circle can be recommended for higher activation of the abdominal muscles in mechanical instability situations and is not recommended when pursuing higher intravaginal pressure.
26

Efeitos da estimulação elétrica neuromuscular na morfologia da musculatura abdominal e peitoral de pacientes críticos em ventilação mecânica

Dall'Acqua, Ana Maria January 2015 (has links)
Objetivo: Avaliar os efeitos da estimulação elétrica neuromuscular (EENM) na espessura muscular abdominal e peitoral de pacientes críticos em ventilação mecânica invasiva (VMI). Metodos: Estudo randomizado duplo cego. Foram incluídos 25 pacientes com idade média de 59±14 anos com no máximo 15 dias de internação hospitalar que estavam com 24 a 48 horas de VMI. Os pacientes foram randomizados para o grupo intervenção (EENM associado a fisioterapia convencional) ou para o grupo convencional (EENM placebo associada a fisioterapia convencional). As intervenções foram realizadas diariamente, tendo duração inicial de 30 minutos, até o sétimo dia ou extubação dos pacientes. Medições e Principais Resultados: O desfecho primário foi espessura muscular transversal do reto do abdomem e peitoral do lado dominante avaliados através da ultrassonografia antes e após o protocolo. Na comparação da interação entre os grupos encontramos diferença significativa (p>0,001), onde as medidas do peitoral e abdominal foram preservadas no grupo intervenção, havendo uma diminuição significativa no grupo controle. Conclusão: Houve preservação da massa muscular no grupo intervenção e uma diminuição significativa das medidas no grupo convencional.
27

Comparação entre o uso de fio inabsorvível (polipropileno) e fio absorvível (poliglactina 910) na fixação de prótese de polipropileno em correção de defeitos músculo-aponeuróticos da parede abdominal: estudo experimental em ratos

Gianlupi, Álvaro January 2002 (has links)
O objetivo deste estudo é comparar a fixação da tela de prolipropileno na correção de defeitos músculo-aponeuróticos da parede abdominal com fio absorvível (poliglactina 910-Vicryl®) e fio inabsorvível (polipropileno-Prolene®). Oitenta e um ratos machos da linhagem Wistar, pesando de 180 a 220g, foram submetidos a ressecção longitudinal de um segmento músculo-aponeurótico e peritoneal (3x2 cm) da parede abdominal, seguida por reforço com tela de polipropileno, em forma de ponte sobre a aponeurose. Foram distribuídos em dois grupos de acordo com o fio usado para fixação da tela: grupo Vicryl® - fixada com 8 pontos separados e eqüidistantes em forma de “U” com fio poliglactina 910 4-0; e grupo Prolene® - fixada com fio polipropileno 4-0. A pele foi suturada com fio mononylon® 4-0. Após 90 dias, os animais foram submetidos à eutanásia e avaliados macroscopicamente, quanto à presença de hérnia e avaliação histológica da reação inflamatória crônica, absorção do fio e percentagem de fibrose pela técnica vídeo-morfométrica assistida por computador. Utilizaram-se as técnicas de coloração de hematoxilina–eosina e picrossírius. Não houve diferença estatisticamente significante entre os grupos, quanto à presença de hérnia incisional (p=0,194). Constatou-se que houve maior fibrose no grupo Prolene pela avaliação histológica de reação inflamatória crônica, o que não foi verificado quando avaliado pela técnica vídeo-morfométrica (p=0,0005). Em relação à reação inflamatória crônica, não houve diferença entre os grupos quando avaliados os gigantócitos, linfócitos e neutrófilos. Houve maior número de macrófagos no grupo Prolene® (p=0,02). Não houve absorção do Vicryl® após 90 dias. Conclui-se que a fixação de tela de polipropileno pode ser feita com êxito com fios absorvíveis como a poliglactina 910 (Vicryl®). / The aim of this study is to assess fixation of a polypropylene mesh in the repair of incisional hernias comparing an absorbable (polyglactin 910) suture and an inabsorbable (polypropylene) one. Eighty-one male rats of the Wistar breed, weighing from 180g to 220g, were submitted to a longitudinally resection of a musculoaponeurotic and peritoneal segment (3x2 cm) of the abdominal wall. Reconstruction was performed by reinforcement with Marlex® mesh, overlaid on the aponeurosis. They were distributed in two groups according to the thread used for mesh fixation as follows: (1) Vicryl® group, fixed with 8 stitches 4.0 Polyglactin 910 suture; and (2) Prolene® group, fixed with 4.0 polypropylene suture. The skin suture was performed with 4.0 mononylon® continuous stitches. After 90 days, animals were sacrificed and submitted to macroscopic evaluation for the presence of hernias. Histologic samples were stained for Hematoxylin-Eosine and Sirius-Red and were assessed for signs of cicatrization such as chronic inflammatory reaction, fibrosis, suture absortion and percentage of fibrosis by computer-assisted video morfometric technic. There was no significant difference between the groups studied in relation to hernia formation (p=0,194). The histologic study showed significant increase of fibrotic reaction in the Prolene® group (p=0,0005), but this finding was not confirmed in the video-morfometric evaluation. Considering chronic inflammatory reaction, there was no difference between groups in relation to giant cells, lymphocytes and neutrophils. However, in the Prolene® group, macrophages were significantly increased (p=0,02). Polyglactin 910 has not been absorved 90 days after the procedure. The results of this study suggest that the fixation of polipropilene mesh is effective using absorbable sutures in the repair of ventral (incisional) hernias.
28

Análise eletromiográfica de exercícios abdominais realizados por mulheres no meio líquido

Figueiredo, Paulo André Poli de January 2004 (has links)
O objetivo deste trabalho foi verificar a atividade elétrica dos músculos oblíquo externo, reto femoral e das porções supra-umbilical e infra-umbilical do reto abdominal, durante a execução de determinados exercícios abdominais realizados no meio líquido. A amostra foi composta por 20 (vinte) mulheres adaptadas ao meio líquido, com idade entre 21 e 29 anos. A atividade elétrica foi coletada com eletrodos de superfície, sendo o sistema de coleta de dados previamente adaptado, evitando o contato com a água. O exercício de flexão de tronco até a posição sentada, realizado em seco, foi utilizado como referência, sendo o valor root mean square (RMS), da fase ascendente deste exercício, empregado para a normalização da amplitude do sinal coletado durante os demais exercícios. Flexões de tronco e de quadril foram realizadas no meio líquido, na posição horizontal, com o apoio de um tubo nos membros superiores e em um ritmo padrão, sendo dois destes exercícios também realizados em máxima velocidade. Foi utilizado ANOVA two ways, em cada músculo, pelos fatores exercícios e fase. Para melhor compreender a ativação em cada fase, utilizou-se ANOVA one way no valor da fase ascendente de cada músculo pelo fator exercício, assim como somente nos valores da fase descendente. Para verificar onde estavam as diferenças, utilizou-se o Post Hoc de Tukey. Os dados foram também normalizados no tempo, sendo apresentados gráficos da atividade eletromiográfica dos músculos durante todo o ciclo de cada exercício. Ao analisar os exercícios como um todo, constatou-se que os exercícios aquáticos em ritmo padrão possuem menor atividade que o de referência Ao analisar a fase ascendente dos exercícios aquáticos em ritmo padrão, o músculo reto abdominal em todos os exercícios, e o oblíquo externo nos exercícios sem apoio são tão eficiente quanto o exercício referência, mostrando que a instabilidade da posição horizontalizada e a resistência ao movimento compensam a diminuição do peso hidrostático. Já na fase descendente, além de menor atividade, o padrão da atividade muscular modifica nos exercícios aquáticos, possivelmente, mantendo uma atividade de estabilização, enquanto outro grupo muscular é responsável pelo movimento. A realização do exercício em máxima velocidade apresentou uma grande atividade eletromiográfica dos músculos abdominais no meio líquido e, para o reto femoral, a amplitude de movimento foi muito importante para sua ativação. Dessa forma, a flexão de tronco em máxima velocidade é um exercício de grande atividade abdominal e baixa atividade dos flexores de quadril. As características das forças externas ao corpo, nos exercícios abdominais realizados no meio líquido, proporcionam uma situação única de redução de peso hidrostático, resistência ao movimento, apoio relativo e tendência de rotação para atingir o equilíbrio estável.
29

Comparação entre o uso de fio inabsorvível (polipropileno) e fio absorvível (poliglactina 910) na fixação de prótese de polipropileno em correção de defeitos músculo-aponeuróticos da parede abdominal: estudo experimental em ratos

Gianlupi, Álvaro January 2002 (has links)
O objetivo deste estudo é comparar a fixação da tela de prolipropileno na correção de defeitos músculo-aponeuróticos da parede abdominal com fio absorvível (poliglactina 910-Vicryl®) e fio inabsorvível (polipropileno-Prolene®). Oitenta e um ratos machos da linhagem Wistar, pesando de 180 a 220g, foram submetidos a ressecção longitudinal de um segmento músculo-aponeurótico e peritoneal (3x2 cm) da parede abdominal, seguida por reforço com tela de polipropileno, em forma de ponte sobre a aponeurose. Foram distribuídos em dois grupos de acordo com o fio usado para fixação da tela: grupo Vicryl® - fixada com 8 pontos separados e eqüidistantes em forma de “U” com fio poliglactina 910 4-0; e grupo Prolene® - fixada com fio polipropileno 4-0. A pele foi suturada com fio mononylon® 4-0. Após 90 dias, os animais foram submetidos à eutanásia e avaliados macroscopicamente, quanto à presença de hérnia e avaliação histológica da reação inflamatória crônica, absorção do fio e percentagem de fibrose pela técnica vídeo-morfométrica assistida por computador. Utilizaram-se as técnicas de coloração de hematoxilina–eosina e picrossírius. Não houve diferença estatisticamente significante entre os grupos, quanto à presença de hérnia incisional (p=0,194). Constatou-se que houve maior fibrose no grupo Prolene pela avaliação histológica de reação inflamatória crônica, o que não foi verificado quando avaliado pela técnica vídeo-morfométrica (p=0,0005). Em relação à reação inflamatória crônica, não houve diferença entre os grupos quando avaliados os gigantócitos, linfócitos e neutrófilos. Houve maior número de macrófagos no grupo Prolene® (p=0,02). Não houve absorção do Vicryl® após 90 dias. Conclui-se que a fixação de tela de polipropileno pode ser feita com êxito com fios absorvíveis como a poliglactina 910 (Vicryl®). / The aim of this study is to assess fixation of a polypropylene mesh in the repair of incisional hernias comparing an absorbable (polyglactin 910) suture and an inabsorbable (polypropylene) one. Eighty-one male rats of the Wistar breed, weighing from 180g to 220g, were submitted to a longitudinally resection of a musculoaponeurotic and peritoneal segment (3x2 cm) of the abdominal wall. Reconstruction was performed by reinforcement with Marlex® mesh, overlaid on the aponeurosis. They were distributed in two groups according to the thread used for mesh fixation as follows: (1) Vicryl® group, fixed with 8 stitches 4.0 Polyglactin 910 suture; and (2) Prolene® group, fixed with 4.0 polypropylene suture. The skin suture was performed with 4.0 mononylon® continuous stitches. After 90 days, animals were sacrificed and submitted to macroscopic evaluation for the presence of hernias. Histologic samples were stained for Hematoxylin-Eosine and Sirius-Red and were assessed for signs of cicatrization such as chronic inflammatory reaction, fibrosis, suture absortion and percentage of fibrosis by computer-assisted video morfometric technic. There was no significant difference between the groups studied in relation to hernia formation (p=0,194). The histologic study showed significant increase of fibrotic reaction in the Prolene® group (p=0,0005), but this finding was not confirmed in the video-morfometric evaluation. Considering chronic inflammatory reaction, there was no difference between groups in relation to giant cells, lymphocytes and neutrophils. However, in the Prolene® group, macrophages were significantly increased (p=0,02). Polyglactin 910 has not been absorved 90 days after the procedure. The results of this study suggest that the fixation of polipropilene mesh is effective using absorbable sutures in the repair of ventral (incisional) hernias.
30

O Magic Circle aumenta a atividade eletromiográfica abdominal e a pressão intravaginal no exercício The Hundred do Método Pilates?

Paulitsch, Alessandra Fayh January 2013 (has links)
O Método Pilates parte do princípio da centralização, no qual todo movimento começa e é sustentado no centro do corpo, chamado de centro de força, ou, ainda, de powerhouse. Com a finalidade de ajudar o praticante do método a localizar o powerhouse, aumentar o controle e o recrutamento dos músculos que o compõem, Joseph Pilates criou o acessório Magic Circle, o qual consiste num aro flexível com aproximadamente 40 cm de diâmetro, utilizado, entre outras finalidades, para aumentar a atividade dos músculos abdominais em alguns exercícios do Método Pilates. O objetivo deste trabalho foi comparar a atividade eletromiográfica abdominal, bem como analisar a pressão intravaginal, nos exercícios The Hundred e The Hundred modificado, executados com e sem o acessório Magic Circle. Foram analisados, simultaneamente, o sinal eletromiográfico de superfície dos músculos reto abdominal, oblíquo externo, oblíquo interno e adutor longo, e a pressão intravaginal durante a execução dos exercícios The Hundred e The Hundred modificado com e sem a utilização do Magic Circle. Verificou-se uma maior atividade nos músculos abdominais apenas quando o Magic Circle foi utilizado em situações de instabilidade, enquanto a pressão intravaginal não foi afetada pelo uso do acessório. O Magic Circle pode ser recomendado para uma maior ativação da musculatura abdominal nas situações de maior instabilidade mecânica e não é recomendado quando se busca uma maior pressão intravaginal. / The Pilates method is based on the centering principle, in which every movement starts and is supported by the center of the body, called strong core or powerhouse. In order to help the practitioner locate the powerhouse and increase the control and recruitment of its muscles, Joseph Pilates created the accessory Magic Circle, which consists of a flexible ring, approximately 40cm wide, used, among other purposes, to increase abdominal muscle activity in some exercises of the Pilates Method. The aim of this study was to compare the abdominal electromiographic activity, as well as to analyze intra-vaginal pressure in the exercises The Hundred and The Hundred modified, performed with and without the accessory Magic Circle. The study simultaneously analyzed the electomiographic signal on the surface of the rectus abdominis, external oblique, internal oblique, aductor longus, as well as intra-vaginal pressure during the performance of the exercises The Hundred and The Hundred modified with and without the use of the Magic Circle. There was higher activity on the abdominal muscles only when the Magic Circle was used in instability situations, while the intra-vaginal pressure was not affected by the use of the accessory. The Magic Circle can be recommended for higher activation of the abdominal muscles in mechanical instability situations and is not recommended when pursuing higher intravaginal pressure.

Page generated in 0.0386 seconds