• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 368
  • 2
  • 1
  • Tagged with
  • 375
  • 375
  • 242
  • 239
  • 56
  • 54
  • 37
  • 34
  • 27
  • 27
  • 27
  • 27
  • 22
  • 22
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Análise térmica e energética de uma edificação residencial climatizada com sistema de Fluxo de Refrigerante Variável -VRF Fernando Pozza

Pozza, Fernando January 2011 (has links)
O trabalho apresenta uma análise térmica e energética de uma edificação localizada na zona bioclimática 1, que compreende as cidades mais frias do Brasil. A análise foi desenvolvida com o auxílio do programa de simulação dinâmica de edificações EnergyPlus em que foi determinado o consumo anual de energia elétrica de toda a edificação existente, bem como o consumo do sistema HVAC (Aquecimento, Ventilação e Ar Condicionado) do tipo split com ciclo reverso. O sistema HVAC existente representa 42% do consumo total de energia elétrica da edificação sendo que o aquecimento totaliza 89% do consumo do sistema HVAC. A avaliação do conforto térmico dos ambientes climatizados da edificação foi realizada tendo como referência as zonas de conforto de inverno e de verão definidas pela ASHRAE Standard 55-2004. Os ambientes apresentaram um percentual de 7,6 % a 33% das horas de operação do sistema HVAC fora da zona de conforto térmico de inverno da ASHRAE, considerando somente a temperatura operativa. A partir dos resultados da simulação da edificação existente foram propostas modificações na envoltória e o uso de um sistema de ar condicionado com tecnologia VRF (fluxo de refrigerante variável) a fim de reduzir o consumo de energia pelo HVAC e o número de horas desconfortáveis. A utilização de vidros duplos de maior transmissividade, superfícies com cores de maior absortividade solar, lã de vidro nas paredes externas e internas duplas e placas de EPS (Poliestireno Expandido) no piso da edificação, apresentaram ótimos resultados, reduzindo o consumo total de energia elétrica em 18,2% e o consumo do sistema HVAC passou a representar apenas 29,6% do total de energia da edificação. Após o aprimoramento da edificação foram selecionadas, a partir de catálogos de fabricantes, as máquinas com tecnologia VRF que atendessem a máxima carga térmica entre os dias de projeto ou arquivo climático sob determinadas condições. Os resultados obtidos com o sistema VRF apresentaram uma redução de 32,8% sobre o consumo de energia do sistema de HVAC e de 9,3 % sobre o consumo total de energia elétrica da edificação quando comparado com um ar condicionado tradicional do tipo split. Com a melhoria na envoltória e o uso da tecnologia VRF para climatização o percentual de horas fora das zonas de conforto da ASHRAE foram menores que os 4% estabelecido pela norma, quando considerado a temperatura operativa. O sistema VRF foi simulado adaptando o módulo de simulação de serpentinas de expansão direta com compressores de velocidade variável, do EnergyPlus, para quatro faixas de capacidades distintas do compressor (60%, 80%, 100% e 120%) e para cada faixa foram inseridas as correlações de desempenho da capacidade e potência elétrica de aquecimento e refrigeração para diferentes condições de operação. Nas simulações foram considerados a perda de desempenho e o consumo elétrico para a operação de degelo com ciclo reverso para temperaturas externas inferiores a 7º C. As simulações com o sistema VRF acoplado a edificação comprovam a capacidade de economizar energia elétrica, além de apresentar o menor custo especifico da energia para aquecimento em relação aos sistemas radiantes. / This dissertation presents the thermal and energetic analysis of a building located in the bioclimatic zone 01, which comprises the coldness regions of Brazil. The analysis was developed using the software for dynamic simulation of buildings called EnergyPlus, where was determined the annual consumption of electricity throughout the existing building as well as the consumption with lighting, electrical equipments and the HVAC system. The existing HVAC system represents 42% of total consumption and the heating corresponds to 89% of the total energy consumption of the HVAC system. The evaluation of thermal comfort zones of building were conducted with reference to the comfort zones of winter and summer from the ASHRAE Standard 55-2004. The thermal zones presented a percentage in the range of 7.6% to 33% of occupation hours outside the boundaries of ASHRAE thermal comfort zone (winter) evaluating the operating temperature. Based on simulation results of the existing building, changes were proposed in the envelope and in the use of a heat pump air conditioning system with VRF technology (variable refrigerant flow) to reduce the energy consumption of the HVAC and the number of hours outside the comfort zone. The use of double layers glasses with high transmissivity and surfaces colored with high solar absorption, wool glass in the external and double internal walls and EPS sheets on the building floor, presented excellent results. The modification of the envelope decreased 18.2 % in the total consumption of electricity and the HVAC system represents only 29.6% of the total energy of the building. After the building improvement was selected from catalogs of manufacturers, machines with VRF technology that could meet the maximum heat load between design days or weather file. The results obtained with the VRF system showed a 32.8% reduction on energy consumption of HVAC system and 9.3% about the total consumption of electricity of the building compared to a traditional heat pump air conditioning system with single speed compressor. With the improvement in the envelope and the use of VRF system the percentage of hours outside the ASHRAE comfort zones were lower than the 4% target set by the standard. The VRF system was modeled from model: Multi-Speed Electric DX Air Coil, of the EnergyPlus, for four different capacities of the compressor (60, 80, 100 and 120%) and for each capacity range were included the performance correlation of heating and cooling capacity, the correlations of electrical power heating and cooling for different condition of operate and correlation of the fraction of part load operation for each machine selected. As the study was conducted to the cooler regions of Brazil, defrost was considered in the simulation with reverse cycle for operating temperatures below 7°C. The heating energy with heat pump VRF presents lower specific cost compared to radiant systems like radiant floor and radiators.
332

Estudo da degradação parcial de filmes de blendas de poli(tereftalato de butileno-co-adipato de butileno) e poli(ácido láctico) no processo de compostagem doméstica. / Study about the partial degradation of poly(butylene adipate-co-terephthalate) and poly(lactic acid) blends in the process of Home Composting.

João de Araújo Junior 11 March 2014 (has links)
Neste trabalho, foram estudadas blendas de poliésteres sintéticos e de fonte renovável - poli(tereftalato de butileno-co-adipato de butileno) - PBAT e poli(ácido láctico) - PLA, respectivamente, utilizados em sacolas de supermercado. Amostras destes materiais foram pesadas e enterradas em solo simulado por quatro meses para simular uma compostagem tradicional. As amostras foram então analisadas por Calorimetria Exploratória Diferencial (DSC), Termogravimetria e Termogravimetria Derivada (TG e DTG, incluindo uma Análise Cinética não isotérmica comparativa com sacolas de PE aditivadas com agente pró-degradante, Espectroscopia Vibracional Raman com Transformada de Fourier (FT-Raman), Difração de Raios X e Cromatografia de exclusão por tamanho. Embora não tenha havido perda de massa significativa no período do envelhecimento por compostagem tradicional, foram constatadas importantes alterações estruturais nas amostras, tais como a redução nas energias de ativação (Ea) para os processos de decomposição térmica, a redução na intensidade da banda relativa ao estiramento da carbonila presente nos poliésteres e também uma drástica redução da massa molecular dos polímeros. Em paralelo, a aceleração do processo de biodegradação com Vermicompostagem foi investigado, com resultados bastante promissores, incluindo a degradação total da amostra após um tratamento prévio de exposição à luz solar. / In this study, blends of the synthetic polyester poly(butylene adipate-cotherephtalate) - PBAT - and the natural one poly(lactic acid) - PLA - used as biodegradable plastic shopping bags were studied. Samples of these materials were weighed and buried in simulated soil for four months to simulate domestic composting. These samples were then studied by Differential Scanning Calorimetry (DSC), Thermogravimetry (TG, including a comparative non-isothermal Kinetic Analysis with PE shopping bags containing prodegradation agents), Transformed Fourier Raman Vibrational Spectroscopy (FT-Raman), Wide Angle X-Ray Diffraction (WAXD) and Gel Permeation Chromatography (GPC). It was observed that even though there was no significant mass loss in the period of the ageing when using conventional home composting, important structural changes were detected in the samples, such as the reduction of activation energies (Ea) for the thermal decomposition processes, the reduction of intensity of the peak associated with the stretching of the carbonyl present in both polyesters and also a dramatic decrease in molecular weights. In parallel, the acceleration of the biodegradation process with vermicomposting was investigated, with very promising results, including the total disintegration of the samples when submitted to a previous treatment of sun light exposure.
333

Desempenho reológico e entálpico da massa de pão com amido resistente de milho e transglutaminase. / Rheological and enthalpy performance of pan bread dough with maize resistant starch and transglutaminase.

Diana Buchner de Oliveira Sanchez 15 May 2009 (has links)
O objetivo desse trabalho foi estudar a influência da substituição parcial da farinha de trigo (FT) por amido resistente de milho (ARM) e da adição da enzima transglutaminase (TG) sobre o desempenho reológico e entálpico da massa de pão. O ARM foi adicionado como uma alternativa de aumentar a ingestão de fibra alimentar (FA), enquanto que a TG foi adicionada como forma de suprir a diluição do glúten, catalisando as ligações. Foram realizadas análise de textura da massa (extensão uniaxial, biaxial e Texture Profile Analysis - TPA), análise térmica de calorimetria exploratória diferencial (DSC) e reológica (reofermentógrafo). De acordo com um planejamento experimental estrela com três pontos centrais e quatro axiais as análises foram conduzidas em cinco níveis de substituição da farinha de trigo (FT) pelo amido resistente de milho (ARM): 1,5 %; 3,5 %; 8,5 %; 13,5 %; 15,5 % (base 100 % mistura) e cinco níveis de adição de enzima transglutaminase (TG): 0,03 %; 0,05 %; 0,10 %; 0,15 %; 0,17 %. As mesmas análises foram realizadas em massa produzida com farinha de trigo (controle), sem adição de ARM e TG. A substituição de FT por ARM influenciou mais os parâmetros de textura do que a adição de TG. A resistência à extensão atingiu um valor 32 % maior que o controle com a substituição de 8,5 % de ARM e adição de 0,12 % de TG. Nos ensaios realizados no DSC foram identificados três picos endotérmicos, sendo eles: fusão da água, gelatinização do amido do trigo (60 °C) e gelatinização do ARM (115 °C). A altura máxima de desenvolvimento da massa (Hm), medida no reofermentógrafo, foi influenciada significativamente, diminuindo com o aumento da adição de ARM. A absorção de água aumentou conforme a adição de fibras, porém até 11 % de substituição por ARM pode ser considerado igual ao controle. No intervalo estudado, a TG não contribuiu positivamente no desempenho da massa e, portanto, baseado nos resultados obtidos, a mistura com substituição de FT por ARM até 8,5 % não influenciará significativamente os seus parâmetros reológicos e de textura, podendo ser utilizada para manufatura de pão com maior teor de fibras. / The objective of this work was to study the partial substitution of wheat flour (WF) to maize resistant starch (MRS) and the addition of transglutaminase enzyme (TG) on the rheological and enthalpy properties of pan bread dough. The MRS was added as an alternative to increase the fiber ingestion while TG was added to supply the gluten dilution, catalyzing the bonds. Texture analyses (uniaxial extension, biaxial extension and Texture Profile Analysis TPA), thermal analysis on Differential Scanning Calorimetric (DSC) and rheological tests (rheofermentometer) were carried out in pan bread dough produced with five levels of wheat flour substitution from maize resistant starch: 1.5 %; 3.5 %; 8.5 %; 13.5 %; 15.5 % (basis on 100 % of mixture) and five addition levels of transglutaminase (TG): 0.03 %; 0.05 %; 0.10 %; 0.15 %; 0.17 % according to a composite design (2²) with three central and four star points. The same tests were conducted in pan bread dough without added MRS and TG and considered as control. The substitution of WF from MRS has more influenced the textural parameters than the addition of TG. The extension strength achieved a value 32 % higher than control with the substitution of 8.5 % of MRS and 0.12 % of TG. During the DSC tests, it has been found three endothermic peaks: fusion of water, gelatinization of wheat starch (60 °C) and gelatinization of MRS (115 °C). The maximum dough height (Hm), obtained from rheofermentometer curves, was significantly influenced, decreasing with the increase the addition of MRS. The absorption of water increased with the fibers addition, however up to 11 % of substitution of MRS, it could be considered equal to the control. TG did not contribute positively on the dough performance, at studied interval, and therefore mixture with substitution of WF by MRS up to 8.5 % will not significantly influence their rheological and texture parameters and can be used to manufacture pan bread with high fiber content.
334

Modelos numéricos de pilares mistos curtos de seções circulares de aço preenchidos com concreto em situação de incêndio / Nonlinear numerical analysis of circular concrete filled steel short columns under fire condition

Rodrigo Tadeu dos Santos 05 March 2009 (has links)
Os pilares mistos de aço preenchidos com concreto, quando submetidos a elevadas temperaturas, apresentam comportamento estrutural bastante satisfatório e reduzem no concreto o fenômeno denominado spalling, devido ao confinamento imposto pelo tubo de aço, mais pronunciado em seções tubulares circulares. Destaca-se ainda a reduzida taxa de aquecimento desse mesmo elemento misto em razão da baixa condutividade térmica do concreto, aspecto de grande interesse para fins de dimensionamento. O presente trabalho tem como principal objetivo modelar numericamente, em campo tridimensional, pilares mistos curtos com seções tubulares circulares de aço, preenchidos com concreto e submetidos ao incêndio-padrão prescrito pela ISO 834:1999. A modelagem se faz com vistas a simular o comportamento estrutural desse elemento em situação de incêndio, buscando avaliar a influência da elevação de temperatura na resistência do elemento e indicar para qual tempo e em que níveis de temperatura o acréscimo de resistência devido ao efeito do confinamento deixa de ser pronunciado. Para a modelagem numérica em campos térmico, estrutural e termo-estrutural, se utiliza o pacote comercial ANSYS ® V9.0, elaborado com base no método dos elementos finitos, o qual permite a análise transiente dos efeitos do gradiente térmico nos elementos estruturais. Os resultados das análises térmica, estrutural e acoplada são previamente comparados com valores obtidos com o código computacional TCD 5.5. A análise acoplada foi realizada para três diâmetros de pilares mistos, e as variações do diâmetro e da resistência à compressão do concreto foram consideradas, possibilitando uma análise paramétrica. Por fim, é apresentada uma análise inversa dos modelos, considerando carregamentos crescentes para campos de temperatura fixos. / Concrete-filled steel columns when subjected to high temperatures present satisfactory structural behavior and the reduction of the spalling phenomenon in the concrete due to confinement action of the steel tube, more notable in circular cross sections. Another advantage is the reduced heating rate of this element due to concrete low thermal conductivity, which is an interesting characteristic in designing procedures. The aim of this work is to develop 3D numerical models of circular concrete-filled steel short columns under fire exposure according to the ISO-834:1999 standard. The numerical models are developed to simulate the structural behavior of those composite short columns under fire condition, in order to evaluate the influence of increasing temperature in the strength of the structural element. This makes possible define the time and the temperature level in which the resistant increment due to the confinement effect is no more appreciable. To perform the numerical model of thermal, structural and thermal-structural fields, a commercial finite element analysis package ANSYS ® V9.0 is used, which allows transient analysis of the thermal gradient effects in the structural elements. The results from thermal, structural and coupled analyses are previously compared with the ones obtained with TCD 5.5 package. The coupled analysis is performed for three different columns, changing the diameter and concrete compression strength to be used in a parametric analysis. Finally, it is shown another analysis type, called reverse analysis, which considers increasing structural loads for fixed temperature fields.
335

Modelos numéricos de vigas mistas de aço e concreto pertencentes a sistemas de pisos mistos de pequena altura em situação de incêndio / Numerical modelling of composite slim floor beams in fire

Fábio Martin Rocha 08 March 2012 (has links)
Os pisos mistos de baixa altura caracterizam um sistema estrutural em que há a incorporação, parcial ou completa, do perfil metálico (viga de aço) na laje de concreto, promovendo a redução da altura da seção e, consequentemente, o aumento da altura útil do pavimento. A incorporação do perfil de aço na laje de concreto garante revestimento ao aço contra o fogo, melhorando o desempenho da viga de aço frente às ações do fogo. Com a finalidade de avaliar o desempenho térmico e estrutural desta solução construtiva, foram desenvolvidos modelos numéricos das vigas parcialmente revestidas presentes nesse sistema estrutural em duas etapas distintas: Na primeira é realizada a análise térmica bidimensional no pacote computacional DIANA para a obtenção dos campos térmicos nas seções transversais das vigas em questão e, a partir daí, considerá-los em um processador de cálculo de momentos plásticos resistentes em todo o intervalo de tempo analisado, sendo então possível avaliar a perda da capacidade portante da seção em função do tempo de exposição ao fogo. A segunda etapa consiste na criação de modelos numéricos tridimensionais em elementos finitos no pacote computacional DIANA, com o qual é possível obter o comportamento estrutural da viga mista de aço e concreto quando exposta ao incêndio padrão, considerando então os efeitos relativos à inclusão do gradiente de temperatura tais como a perda das propriedades mecânicas, a expansão e a interação entre os materiais. Tendo em vista as funcionalidades do código computacional DIANA, diversos modelos foram construídos procurando atingir a melhor aproximação com os resultados experimentais apresentados na literatura associados ao menor custo computacional possível. Dessa forma, foram analisados casos com (1) interação parcial e total entre o aço e o concreto e com (2) diferentes modelos constitutivos para os materiais em questão. Por fim, os resultados obtidos com a análise numérica a partir do DIANA são comparados com os do método dos momentos plásticos, que por sua vez, apresentam um custo computacional bastante reduzido / Slim floor frames consists on structural system in which the steel beam is completely or partially inserted in a concrete slab, that is usually used in profiled steel decks systems. The main goal of the slim floor systems is to obtain a minimum height of the composite beam section and, consequently, achieve a higher height of the floor or a lower total height of the building. The partial encasement of the steel beam in the concrete slab provides a thermal protection, improving the behavior of the beam when subjected to fire. In order to evaluate the thermal and structural behavior of the slim floor system, numerical models considering partially encased beams, which can be found in the slim floor structures, were created. The numerical evaluation procedure was divided in two steps. In the first step, a two-dimensional thermal analysis is carried out using the general finite-element software TNO DIANA to obtain the temperatures gradient in the cross section during the fire exposure time and then, use the data in a computational code developed in FORTRAN which calculates the bearing capacity, over the exposure time, of the slim floor beams by means of the plastic moment capacity method, using the reduction factors associated to the mechanical properties of the materials presented in Eurocode 4. The second step consists in to develop three-dimensional numerical models using the software TNO DIANA and then obtain the complete structural behavior of the beam when subjected to a fire condition. Another aspect related to the loss of mechanical properties was also considered, such as the thermal expansion and the interaction between the steel and the concrete. In view of the DIANA functions, several models were developed in order to achieve a better approximation, a low computational cost, of some tests results presented in wide world literature. The cases of partial and complete interaction between the materials were analyzed, as well as the different constitutive models for them, so that the results obtained at the two steps were compared, and an evaluation of the methods was done
336

Desenvolvimento e aplicação de código computacional para análise de estruturas de aço aporticadas em situação de incêndio / Development and application of computational code for steel frame analysis in fire situation

Ronaldo Rigobello 17 October 2011 (has links)
O presente trabalho teve por objetivo desenvolver um código computacional com base no método dos elementos finitos, para análises termoestruturais de estruturas de aço aporticadas quando expostas a ações térmicas típicas de situações de incêndio. O código utilizado nas análises estruturais emprega elemento finito de pórtico não linear 3-D de formulação posicional. A formulação posicional utiliza como graus de liberdade as posições dos nós ao invés dos deslocamentos, resultando em uma descrição intrinsecamente não linear do comportamento geométrico das estruturas. Podem ser consideradas seções transversais quaisquer com o elemento finito em questão, e sua representação geral é tridimensional. Adota-se uma lei constitutiva tridimensional completa e a cinemática de Reissner, de modo que o modelo de plasticidade considera o efeito combinado das tensões normais e cisalhantes para verificação do critério 3-D de plasticidade. O código computacional desenvolvido permite que sejam realizadas análises térmicas transientes com base no método dos elementos finitos para se determinar campos de temperatura nas seções transversais dos elementos estruturais sujeitos ao fogo. Assim, a influência da temperatura nas propriedades dos materiais é levada em consideração para se avaliar o desempenho da estrutura em cada instante da análise em situação de incêndio, até que o colapso estrutural seja verificado. Análises de casos presentes na literatura são utilizados para validar os resultados obtidos, os quais comprovam a precisão do código computacional desenvolvido e da formulação posicional quando aplicados a análises de estruturas de aço aporticadas à temperatura ambiente e em situação de incêndio. / The present work deals with the development of a computational code based on the finite element method for thermo-structural analyses of steel framed structures when exposed to typical thermal actions of fire condition. The structural analysis is performed considering a computer code that uses 3-D frame nonlinear finite elements of positional formulation. This formulation is based on the positions of the finite element nodes, instead of displacements, which results in an intrinsically nonlinear description of the geometric behavior of structures. The cross-sections of finite elements can be of any geometry due to the tridimensional representation. A complete tridimensional constitutive law is used and, therefore, the effect of combined normal and shear stresses is taken into account for the tridimensional plasticity evolution. The developed computational code allows performing transient thermal analyses to determine the temperature field over the cross-sections of the structural elements subjected to fire. The influence of temperature on the material properties is considered to evaluate the structure response at each defined instant of the fire analysis, until the collapse occurs. The achieved results, when compared to those found in the literature, allow verifying the precision of the developed computational code when applied to steel frame analysis at ambient temperature and in fire situation.
337

Análise térmica e energética de uma edificação residencial climatizada com sistema de Fluxo de Refrigerante Variável -VRF Fernando Pozza

Pozza, Fernando January 2011 (has links)
O trabalho apresenta uma análise térmica e energética de uma edificação localizada na zona bioclimática 1, que compreende as cidades mais frias do Brasil. A análise foi desenvolvida com o auxílio do programa de simulação dinâmica de edificações EnergyPlus em que foi determinado o consumo anual de energia elétrica de toda a edificação existente, bem como o consumo do sistema HVAC (Aquecimento, Ventilação e Ar Condicionado) do tipo split com ciclo reverso. O sistema HVAC existente representa 42% do consumo total de energia elétrica da edificação sendo que o aquecimento totaliza 89% do consumo do sistema HVAC. A avaliação do conforto térmico dos ambientes climatizados da edificação foi realizada tendo como referência as zonas de conforto de inverno e de verão definidas pela ASHRAE Standard 55-2004. Os ambientes apresentaram um percentual de 7,6 % a 33% das horas de operação do sistema HVAC fora da zona de conforto térmico de inverno da ASHRAE, considerando somente a temperatura operativa. A partir dos resultados da simulação da edificação existente foram propostas modificações na envoltória e o uso de um sistema de ar condicionado com tecnologia VRF (fluxo de refrigerante variável) a fim de reduzir o consumo de energia pelo HVAC e o número de horas desconfortáveis. A utilização de vidros duplos de maior transmissividade, superfícies com cores de maior absortividade solar, lã de vidro nas paredes externas e internas duplas e placas de EPS (Poliestireno Expandido) no piso da edificação, apresentaram ótimos resultados, reduzindo o consumo total de energia elétrica em 18,2% e o consumo do sistema HVAC passou a representar apenas 29,6% do total de energia da edificação. Após o aprimoramento da edificação foram selecionadas, a partir de catálogos de fabricantes, as máquinas com tecnologia VRF que atendessem a máxima carga térmica entre os dias de projeto ou arquivo climático sob determinadas condições. Os resultados obtidos com o sistema VRF apresentaram uma redução de 32,8% sobre o consumo de energia do sistema de HVAC e de 9,3 % sobre o consumo total de energia elétrica da edificação quando comparado com um ar condicionado tradicional do tipo split. Com a melhoria na envoltória e o uso da tecnologia VRF para climatização o percentual de horas fora das zonas de conforto da ASHRAE foram menores que os 4% estabelecido pela norma, quando considerado a temperatura operativa. O sistema VRF foi simulado adaptando o módulo de simulação de serpentinas de expansão direta com compressores de velocidade variável, do EnergyPlus, para quatro faixas de capacidades distintas do compressor (60%, 80%, 100% e 120%) e para cada faixa foram inseridas as correlações de desempenho da capacidade e potência elétrica de aquecimento e refrigeração para diferentes condições de operação. Nas simulações foram considerados a perda de desempenho e o consumo elétrico para a operação de degelo com ciclo reverso para temperaturas externas inferiores a 7º C. As simulações com o sistema VRF acoplado a edificação comprovam a capacidade de economizar energia elétrica, além de apresentar o menor custo especifico da energia para aquecimento em relação aos sistemas radiantes. / This dissertation presents the thermal and energetic analysis of a building located in the bioclimatic zone 01, which comprises the coldness regions of Brazil. The analysis was developed using the software for dynamic simulation of buildings called EnergyPlus, where was determined the annual consumption of electricity throughout the existing building as well as the consumption with lighting, electrical equipments and the HVAC system. The existing HVAC system represents 42% of total consumption and the heating corresponds to 89% of the total energy consumption of the HVAC system. The evaluation of thermal comfort zones of building were conducted with reference to the comfort zones of winter and summer from the ASHRAE Standard 55-2004. The thermal zones presented a percentage in the range of 7.6% to 33% of occupation hours outside the boundaries of ASHRAE thermal comfort zone (winter) evaluating the operating temperature. Based on simulation results of the existing building, changes were proposed in the envelope and in the use of a heat pump air conditioning system with VRF technology (variable refrigerant flow) to reduce the energy consumption of the HVAC and the number of hours outside the comfort zone. The use of double layers glasses with high transmissivity and surfaces colored with high solar absorption, wool glass in the external and double internal walls and EPS sheets on the building floor, presented excellent results. The modification of the envelope decreased 18.2 % in the total consumption of electricity and the HVAC system represents only 29.6% of the total energy of the building. After the building improvement was selected from catalogs of manufacturers, machines with VRF technology that could meet the maximum heat load between design days or weather file. The results obtained with the VRF system showed a 32.8% reduction on energy consumption of HVAC system and 9.3% about the total consumption of electricity of the building compared to a traditional heat pump air conditioning system with single speed compressor. With the improvement in the envelope and the use of VRF system the percentage of hours outside the ASHRAE comfort zones were lower than the 4% target set by the standard. The VRF system was modeled from model: Multi-Speed Electric DX Air Coil, of the EnergyPlus, for four different capacities of the compressor (60, 80, 100 and 120%) and for each capacity range were included the performance correlation of heating and cooling capacity, the correlations of electrical power heating and cooling for different condition of operate and correlation of the fraction of part load operation for each machine selected. As the study was conducted to the cooler regions of Brazil, defrost was considered in the simulation with reverse cycle for operating temperatures below 7°C. The heating energy with heat pump VRF presents lower specific cost compared to radiant systems like radiant floor and radiators.
338

Dexametasona : interação com ácidos carboxílicos aromáticos no estado sólido / Dexamethasone : interaction with aromatic carboxylic acids in solid-state

Bergamini, Giovana January 2008 (has links)
A dexametasona (DEX) está entre os glicocorticóides mais comumente descritos para uso sistêmico apresentando uma atividade gliconeogênica, imunossupressora e antiinflamatória bem difundida. Apresenta, em sua estrutura, sítios com potencial capacidade de interação com outras moléculas. Alguns ácidos carboxílicos aromáticos (ACA) e seus derivados são utilizados como excipientes em formulações farmacêuticas e também possuem grupos funcionais com propriedades potenciais de interação. Esta associação aparece, portanto, como um bom modelo de estudo para a compreensão de interações em estado sólido. Este trabalho foi desenvolvido para verificar a existência de interações, no estado sólido, da DEX com os ACA: benzóico, salicílico, 4-hidróxi-benzóico, 2,4-diidróxi-benzóico, 2,3,4-triidróxi-benzóico, gálico, 3-hidróxi-fenilacético, 3,4-diidróxi-fenilacético e isoftálico. A fim de elucidar o comportamento destes sólidos em misturas físicas binárias equiponderais foram empregadas técnicas de calorimetria exploratória diferencial (DSC), espectroscopia no infravermelho e difratometria de raios-X. A dexametasona (DEX) está entre os glicocorticóides mais comumente descritos para uso sistêmico apresentando uma atividade gliconeogênica, imunossupressora e antiinflamatória bem difundida. Apresenta, em sua estrutura, sítios com potencial capacidade de interação com outras moléculas. Alguns ácidos carboxílicos aromáticos (ACA) e seus derivados são utilizados como excipientes em formulações farmacêuticas e também possuem grupos funcionais com propriedades potenciais de interação. Esta associação aparece, portanto, como um bom modelo de estudo para a compreensão de interações em estado sólido. Este trabalho foi desenvolvido para verificar a existência de interações, no estado sólido, da DEX com os ACA: benzóico, salicílico, 4-hidróxi-benzóico, 2,4-diidróxi-benzóico, 2,3,4-triidróxi-benzóico, gálico, 3-hidróxi-fenilacético, 3,4-diidróxi-fenilacético e isoftálico. A fim de elucidar o comportamento destes sólidos em misturas físicas binárias equiponderais foram empregadas técnicas de calorimetria exploratória diferencial (DSC), espectroscopia no infravermelho e difratometria de raios-X. / Dexamethasone is one of the most prescribed glucocorticoid drugs for systemic use with gluconeogenic, immunosuppressive and anti-inflammatory properties. Its molecule shows some interesting reactive sites, which can undergo physical associations with other substances. Aromatic carboxylic acid or derivatives are employed as excipients in pharmaceutical formulations and due to the presence of functional groups with potential interaction ability they can be considered so much as DEX as suitable models for a better understanding of interaction phenomena in binary mixtures in solid state. Following aromatic carboxylic acids were investigated: benzoic, salicylic, 4-hydroxybenzoic, 2,4-dihydroxybenzoic, 2,3,4-trihydroxybenzoic, gallic, 3-hydroxyphenylacetic, 3,4-dihydroxyphenylacetic and isophthalic. The occurrence of interaction was analyzed by differential scanning calorimetry (DSC), infrared spectroscopic and X-ray diffractometric techniques in order to elucidate the behavior of equiponderal binary physical mixtures. The characterization of the interactions was also performed by using molecular modeling tools. The results showed the interaction between the ACA and the DEX. Interaction potential was related neither to the number nor to the position of the hydroxyl groups in the aromatic ring of the ACA. Correlation analysis of the ACA’s theoretic pka and log P with thermal parameters were employed to explain the contribution of the molecules and some elected sites in the referred interactions. The relationship with Log P was satisfactory being its correlation coefficient equal to 0.71. The interactions induced an improvement of DEX hydrosolubility supporting the results originated from the solid state analyses, which suggested the occurrence of hydrogen bonds between dexamethasone and the evaluated ACA.
339

Analise termica na solidificação de ferros fundidos cinzentos hipoeuteticos / Thermal analysis on solidification of hypoeutectic gray cast iron

Silva, Jorge Ayrton da 13 February 2007 (has links)
Orientador: Amauri Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-08T17:48:12Z (GMT). No. of bitstreams: 1 Silva_JorgeAyrtonda_M.pdf: 5941604 bytes, checksum: 9ec8b76ce4cbb57c06994f1a8307f767 (MD5) Previous issue date: 2007 / A análise térmica é amplamente utilizada como método de controle de processos metalúrgicos e na investigação da composição química de ferros fundidos na prática de fundição. Um meio confiável de avaliação da composição de ferros fundidos é disponibilizado pela técnica do Carbono Equivalente, que é baseada na mudança de inclinação da curva de resfriamento na temperatura liquidus durante o resfriamento de uma amostra de ferro fundido a partir do estado líquido. O presente trabalho é focado no desenvolvimento de um novo sensor para análise térmica, um sensor de imersão, que objetiva contribuir com determinações mais confiáveis de composição durante as operações de fundição. Foram desenvolvidos experimentos em diferentes empresas de fundição, utilizando-se tanto o sensor de imersão quanto o tradicional sensor tipo cápsula, normalmente utilizado na prática de fundição. As comparações de composições químicas, medidas por essas duas técnicas e medidas fornecidas por análise de espectrometria de emissão óptica, demonstram que geralmente o sensor de imersão fornece resultados mais confiáveis. Uma análise térmica realizada durante o resfriamento de ferro fundido em um dispositivo unidirecional com uma coquilha, e utilizando um conjunto de termopares, permitiu também a determinação quantitativa de variáveis térmicas de solidificação, tais como: coeficientes transitórios de transferência de calor metal/molde e molde/ambiente e taxa de resfriamento à frente da isoterma liquidus / Abstract: Thermal analysis is a widely used method for metallurgical process control and investigation of alloy composition of cast irons in foundry practice. A reliable means of rapidly evaluating the composition of cast irons is available by the Carbon-Equivalent technique, which is based on the change in thermal arrest temperature of the liquidus as the sample of molten cast iron freezes. The present work focuses on the development of a new sensor for thermal analysis, a dip-sensor, wich aims to contribute to more reliable determination of alloy composition during casting operation. Experiments were carried-out in different foundries by using both the dipsensor and the traditional capsule-sensor, which is normally used in foundry practice. The comparison of alloy compositions measured by these two techniques with analysis performed by Arc/Spark spectrometry has shown that generally the dip-sensor provides more reliable results. Thermal analysis conducted during cooling of molten cast iron in a unidirectional chill apparatus, by using a set of thermocouples, has also permitted the quantitative determination of solidification thermal variables, such as: transient metal/mold and mold/ambient heat transfer coefficients and tip cooling rates / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
340

Desenvolvimento de método químico analítico forense para análise de merla por Análise Térmica e Cromatografia Gasosa de Alta Resolução / Development of forensic analytical chemistry method for examination of merla by Thermal Analysis and High Resolution Gas chromatography

MEDEIROS, Rodrigo Irani 18 March 2011 (has links)
Made available in DSpace on 2014-07-29T15:11:10Z (GMT). No. of bitstreams: 1 Tese Rodrigo I Medeiros.pdf: 2094204 bytes, checksum: 5d1ccae92a1ff1a8355428a531e6a4b9 (MD5) Previous issue date: 2011-03-18 / An analytical chemical method for the forensic analysis of an illicit drug merla, whose the main constituent is the cocaine was development. Thermogravimetric analysis admitted to understand the thermal behavior of samples and quantifying the stages of mass loss, which together with the quantification endothermic event in DSC, the results were essential for the generation of analytical answers used to construct the data matrix of the statistical analysis. An efficient process for the precipitation of inorganic substances was established, which simultaneously allowed the extraction of two liquid fractions, organic and aqueous, being determinate a partition coefficient of 96,22 % for cocaine, using ethyl acetate as solvent, which showed lower elution time (0.58 min.) among the solvents evaluated. A method by Fast GC for cocaine analysis was developed, reducing the analysis time of 14.5 to 4.5 min was developed, which allowed analyze merla sample and the normalization of the chromatographic peaks of cocaine, demonstrated the great variation of its concentration in merla. Noticed of the potential of the method involving the thermo-analytical and chromatographys techniques to generate experimental results obtained statistically enabled a classification and grouping of samples by Euclidean Distance by the Hierarchical Cluster Analysis (HCA), estimated whether seized samples with different users were manipulated in the same laboratory and if determined city has separate laboratories for illegal preparatiom of drug narcotic. / Neste estudo realizou-se o desenvolvimento de um método químico analítico forense para a análise de uma droga ilícita a base de cocaína, a merla. As análises termogravimétricas permitiram conhecer o comportamento térmico das amostras e quantificar as etapas de perdas de massa, que juntamente com a quantificação de evento endotérmico em DSC, foram essenciais para a geração de resultados analíticos utilizados na construção da matriz de dados do tratamento estatístico. Foi estabelecido um processo eficiente para a precipitação das substâncias inorgânicas, que simultaneamente permitiu a extração de duas frações líquidas, orgânica e aquosa, sendo determinado um coeficiente de partição de 96,22 % para a cocaína, tendo como solvente acetato de etila, o qual apresentou menor tempo de eluição (0,58 min.) dentre os solventes avaliados. Foi desenvolvido um método Fast GC para análise de cocaína, diminuindo o tempo de análise de 14,5 min para cerca de 4,5 min, o qual permitiu analisar as amostras de merla e, pela normalização dos picos cromatográficos da cocaína, perceber a grande variação de sua concentração na merla. Observou-se o potencial do método envolvendo as técnicas termoanalíticas e cromatográficas para geração de resultados experimentais que tratados estatisticamente possibilitaram a classificação e o agrupamento das amostras pela distância euclidiana obtida por Análise Hierárquica de Agrupamentos (HCA), avaliando se amostras apreendidas com diferentes usuários foram manipuladas em um mesmo laboratório e se determinada cidade possui laboratórios distintos de preparo ilegal de tóxico-entorpecente.

Page generated in 0.4235 seconds