• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 5
  • 4
  • Tagged with
  • 71
  • 71
  • 50
  • 50
  • 49
  • 45
  • 38
  • 36
  • 22
  • 21
  • 17
  • 16
  • 16
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Étude sur l'utilisation de liquides ioniques à base imidazolium pour l'extraction sélective de phosphopeptides

Sanon, Samantha Herntz 04 1900 (has links)
La phosphorylation des protéines constitue l’une des plus importantes modifications post-traductionnelles (PTMs) et intervient dans de multiples processus physiologiques tels, la croissance, la différenciation cellulaire, l’apoptose, etc. En dépit de son importance, l’analyse des phosphoprotéines demeure une tâche difficile en raison de leur nature dynamique (car la phosphorylation des protéines est un processus réversible) et de leur faible abondance relative. En effet, la détermination des sites de phosphorylation est souvent difficile car les phosphopeptides sont souvent difficiles à détecter par des méthodes d’analyse chromatographique classique et par spectrométrie de masse (MS). De récentes études ont démontré que les nombreuses méthodes d’enrichissement de phosphopeptides existantes ne sont pas complètes, et que le nombre total de phosphopeptides détectés ne chevauchent pas complètement ces méthodes. C’est pour cela qu’il existe une nécessité de combler les lacunes des méthodes d’enrichissement existantes afin d’avoir des analyses phosphoprotéomiques plus complètes. Dans cette étude, nous avons utilisé les liquides ioniques (LI), plus particulièrement les sels d’imidazolium, comme une technique d’enrichissement alternative, dans le but de favoriser une extraction sélective de phosphopeptides présents en solution. Les sels d’imidazolium ont donc été utilisés en raison de leurs propriétés physico-chimiques "facilement" ajustables selon la nature des substituants sur le noyau imidazolium et la nature de l’anion. Les sels de monoimidazolium et de bis-imidazolium possédant respectivement des chaînes linéaires à 4, 12 et 16 atomes de carbone et ayant différents anions ont été synthétisés et utilisés pour effectuer des extractions liquide-liquide et solide-liquide des phosphopeptides en solution. Dans un premier temps, des extractions liquide-liquide ont été réalisées en utilisant un liquide ionique (LI) ayant une chaine linéaire de 4 atomes de carbone. Ces extractions réalisées avec le bis(trifluoromethanesulfonyl) amide de 3-butyl-1-methylimidazolium (BMIM-NTf2) et l’hexafluorophosphate de 3-butyl-1-methylimidazolium (BMIM-PF6) n’ont pas montré une extraction notable du PPS comparativement au PN. Dans un deuxième temps, des extractions solide-liquide ont été réalisées en fonctionnalisant des particules solides avec des sels d’imidazolium possédant des chaines linéaires de 12 ou 16 atomes de carbone. Ces extractions ont été faites en utilisant un phosphopentapeptide Ac-Ile-pTyr-Gly-Glu-Phe-NH2 (PPS) en présence de 2 analogues acides non-phosphorylés. Il a été démontré que les sels d’imidazolium à chaine C12 étaient meilleurs pour extraire le PPS que les deux autres peptides PN (Ac-Ile-Tyr-Gly-Glu-Phe-NH2) et PE (Ac-Glu-Tyr-Gly-Glu-Phe-NH2) L’électrophorèse capillaire (CE) et la chromatographie liquide à haute performance couplée à la spectrométrie de masse (LC-MS) ont été utilisées pour quantifier le mélange des trois peptides avant et après extraction ; dans le but de mesurer la sélectivité et l’efficacité d’extraction de ces peptides par rapport à la composition chimique du liquide ionique utilisé. / Protein phosphorylation is one of the most important post-translational modifications because it is involved in multiple physiological processes such as growth, differentiation, apoptosis, etc. Despite its importance, the analysis of phosphoproteins remains a difficult task due to their dynamic nature (phosphorylation of proteins is a reversible process) and their low abundance. Indeed, the determination of phosphorylation sites is difficult because phosphopeptides are often difficult to detect by conventional chromatographic analysis and by mass spectrometric (MS) methods. Recent studies have shown that the existing methods of enrichment of phosphopeptides are not complete, and the total number of phosphopeptides detected does not overlap completely with those detected by these methods. The gaps in existing enrichment methods need to be filled in order to have more complete phosphoproteomic analyses. In the current study, ionic liquids (IL), specifically imidazolium salts, have been used in an alternative enrichment technique with potential for selective extraction of phosphopeptides from solution. Imidazolium salts were chosen because their physicochemical properties are readily adjustable depending on the nature of the substituent attached to the imidazolium core and the counter-anion. Monoimidazolium and bis-imidazolium salts with linear chains having respectively 4, 12, and 16 carbon atoms and with different anions were synthesized and used to carry out liquid-liquid and solid-liquid extractions of a phosphorylated peptide from a solution. At first, liquid-liquid extractions were carried out using an ionic liquid (IL) with a linear chain of 4 carbon atoms. These extractions performed with bis (trifluoromethanesulfonyl) amide 3-butyl-1-methylimidazolium (BMIM-NTf2) and hexafluorophosphate 3-butyl-1-methylimidazolium (BMIM-PF6) did not show a considerable extraction of PPS comparatively to the PN. Secondly, solid-liquid extractions were done by first functionalizing solid-phase particles with the imidazolium salts. The extractions were carried out using the phosphopentapeptide Ac-pTyr-Ile-Gly-Glu-Phe-NH2 (PPS) and its acidic non-phosphorylated analogues. It has been shown that the C12 chain imidazolium salts were better to extract PPS than the other two peptides PN (Ac-Ile-Tyr-Gly-Glu-Phe-NH2) and PE (Ac-Glu-Tyr-Gly-Glu-Phe-NH2). The extraction efficiency of these peptides was estimated by capillary electrophoresis (CE) and high performance liquid chromatography coupled with mass spectrometry (LC-MS).
62

Aspects analytiques, cliniques et médico-judiciaires des nouvelles substances psychoactives / Analytical, clinical and forensic aspects of new psychoactive substances

Ameline, Alice 14 June 2019 (has links)
En raison de la diffusion incontrôlée sur le e-commerce, la sécurité et l’alternative légale aux stupéfiants habituels, les nouvelles substances psychoactives (NPS), d’apparition récente (2008), sont au cœur des phénomènes récents d’addiction et de décès mal expliqués. Au-delà des différents défis dans nos sociétés (prévention, législation), la capacité d’identifier les NPS dans des échantillons biologiques pour caractériser leur utilisation, présente de nombreux challenges analytiques. L’objectif principal de cette thèse a été de collecter des échantillons biologiques (sang, urine, cheveux) provenant de cas d’exposition à des NPS et d’y caractériser les substances présentes à l’aide de méthodes analytiques originales, dans le but d’enrichir les librairies de spectres de masse et d’améliorer, en conséquence, la détection de la consommation de NPS. En particulier, il s’agissait d’augmenter la fenêtre de détection de la prise de NPS en se focalisant sur les métabolites qui sont, le plus souvent, les produits majeurs d’élimination. Le développement analytique, par chromatographie liquide ultra haute performance couplée à la spectrométrie de masse en tandem (UHPLC-MS/MS), a demandé plusieurs mois d’optimisation afin d’obtenir une méthode robuste, exhaustive et sensible. Actuellement, la librairie de spectres MS comporte 114 NPS et est mise à jour régulièrement. A la suite de ce développement, ma thèse a porté sur l’étude de cas d’intoxication vus au service des urgences du CHU de Strasbourg, mais aussi en médecine légale, avec des situations de décès et d’identification de produits inconnus provenant de saisies (poudres et cristaux). Il a également été nécessaire de développer des outils analytiques complémentaires, tels que la caractérisation de métabolite(s) par étude sur microsomes hépatiques humains (HLMs), et l’utilisation de la spectroscopie par résonance magnétique nucléaire (RMN) afin d’identifier avec certitude certains composés et de déterminer leur degré de pureté. Les outils analytiques développés et la stratégie mise en place ont permis la rédaction de 18 publications, ainsi que l’agencement de nombreuses collaborations. / Due to the uncontrolled spread on the Internet and their legal alternative to usual drugs, the new psychoactive substances (NPS), recently appeared (2008), are at the center of recent phenomena of addiction and badly explained deaths. Beyond different challenges in our societies (prevention, legislation), the ability to identify NPS in biological samples, in order to characterize their use, presents many analytical challenges. The main objective of this thesis was to collect biological samples (blood, urine, hair) from cases of exposure to NPS and to characterize the substances present using original analytical methods, in order to enlarge the libraries of mass spectra and improve, as a result, the detection of NPS consumption. In particular, it was intended to increase the detection sensitivity of NPS intake by focusing on the metabolites that are often the major products of elimination. This analytical development, by ultra-high liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS), required several months of optimization in order to obtain a robust, exhaustive and sensitive method. At present, the mass spectra database has 114 NPS and is regularly updated. Thereafter, ma thesis focused on the study of cases of intoxication observed in the emergency department of Strasbourg, but also in legal medicine with situations of deaths and identification of unknown products collected from seizures (powders and crystals). It has also been necessary to implement complementary analytical tools, such as the characterization of metabolites by human liver microsomes (HLMs), and the use of nuclear magnetic resonance (NMR) spectroscopy to accurately identify the compounds and establish their purity degrees. The analytical tools developed, and the strategy adopted, allowed the writing of 18 publications, as well as the setting up of numerous collaborations.
63

Développement de méthodes chromatographiques liquides multidimensionnelles couplées à la spectrométrie de masse, préparation et analyse d'échantillons biologiques complexes.

Delmotte, Nathanaël 12 July 2007 (has links) (PDF)
Des immunoadsorbeurs ont été développés à partir de disques CIM monolithiques pour l'analyse de biomarqueurs impliqués dans des maladies cardio-vasculaires. Les colonnes développées ont permis d'isoler sélectivement la myoglobine et le NT-proBNP du sérum humain. Les colonnes anti-NT-proBNP ont permis l'isolation quantitative du NT-proBNP (R2=0,998) à des concentrations jusqu'à 750 amol/μL de sérum.<br />Six matériaux à accès restreints ont été évalués en fonction de leur aptitude à exclure l'hémoglobine d'hémolysats sanguins. Des injections à différents pH ont montré que la rétention de l'hémoglobine est drastiquement restreinte à pH 10,7. En raison d'une bonne stabilité à pH basique, la colonne polymérique Biotrap 500 MS RAM a été retenue pour l'extraction d'antibiotiques d'hémolysats sanguins. Des extractions quantitatives d'analytes à faibles concentrations (200 pg/μL) ont été réalisées sans effet mémoire d'hémoglobine sur la colonne.<br />Un nouveau système 2D-HPLC-ESI-MS/MS pour l'analyse protéomique a été développé. Le système est composé d'une séparation par RP-HPLC à pH 10,0, suivie d'une séparation par IP-RP-HPLC à pH 2,1. Ce nouveau système a été comparé à un système conventionnel SCX x IP-RP-HPLC. L'orthogonalité des méthodes de séparation est plus élevée dans l'approche SCX x IP-RP-HPLC que dans le schéma RP x IP-RP-HPLC. Cependant, en raison d'une meilleure distribution des peptides et d'une meilleure efficacité de séparation, le système RP x IP-RP-HPLC permet d'identifier significativement plus de peptides. Les deux approches sont complémentaires et une combinaison des deux systèmes permet d'identifier plus de peptides que des analyses répétées par un système unique.
64

Développement de techniques analytiques pour la détermination des agents anti-infectieux dans les eaux environnementales

Segura, Pedro A. 08 1900 (has links)
Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles. / Anti-infectives are used to treat or prevent infections in humans, animals, insects and plants. The occurrence of traces of these substances in wastewaters, natural waters and even drinking water has caused concern among the scientific community especially because of their biological activiy. The goal of this research was to study the occurrence of anti-infectives in contaminated environmental waters (wastewaters, natural waters, and drinking water) and to develop new analytical methods able to quantitate and confirm their presence in these matrices. A meta-analysis on the occurrence of anti-infectives in contaminated environmental waters demonstrated that at least 68 parent compounds and 10 transformation products have been quantified to date. Environmental concentrations vary between 0.1 ng/L and 1 mg/L depending on the compound, the matrix and the source of contamination. According to this study, detrimental effects of anti-infectives on aquatic biota are possible and these substances could also affect indirectly human health because of their possible contribution to the dissemination of antibiotic resistance in bacteria. Preliminary tests on the development of a method of determination of anti-infectives in wastewaters showed the main difficulties to overcome during solid-phase extraction (SPE) as well as the importance of the detector selectivity. A novel method of determination of anti-infectives was described using off-line tandem SPE and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Six target anti-infectives (sulfamethoxazole, trimethoprim, ciprofloxacin, levofloxacin, clarithromycin and azithromycine) were quantitated at concentrations between 39 and 276 ng/L in samples of influent and effluent collected from a primary and physico-chemical wastewater treatement plant. Reported effluent concentrations indicate that the mean mass of these substances discharged daily in the St. Lawrence River was ~ 2 kg. In order to reduce total analysis time and simplify sample preparation, a new on-line SPE-LC-MS/MS was presented. This method used a column-switching technique to preconcentrate 1.00 mL of sample in an on-line SPE column. Method analytical performance allowed the quantitation of six anti-infectives in municipal wastewaters and limits of detection were of the same magnitude (13-60 ng/L) than methods based in offline SPE. Next, the application of turbulent flow chromatography on-line SPE columns for the preconcentration of six anti-infectives in wastewaters was explored. Results showed that these columns are an interesting alternative to traditional on-line SPE columns. Finally, in order to allow analysis of anti-infectives in surface and drinking water, we developed an on-line SPE-LC-MS/MS method using large-volume injections (10 mL). Breakthrough volumes of several on-line SPE columns were estimated and the column having the best retention, Strata-X, was chosen. Method detection and confirmation limits were between 1 and 6 ng/L. Analysis of real samples indicated that the concentration of the three target anti-infectives (sulfamethoxazole, trimethoprim and clarithromycin) was lower that the method detection limits. Accurate mass measurement by time-of-flight mass spectrometry and product ion spectra obtained by a reversed-energy ramp in a triple quadrupole mass spectrometer were explored as alternative confirmation methods.
65

Effet de la stérilisation par éléctrons accélérés sur les COC et sur l'impact des interactions avec des molécules actives.

Barakat, Hala 24 January 2013 (has links) (PDF)
L'objectif de ce travail de thèse était d'étudier l'effet de la stérilisation par électrons accélérés sur les copolymères d'oléfines cycliques (COC), utilisés comme conditionnement de produits pharmaceutiques, ainsi que son impact sur les interactions avec des formulations pharmaceutiques. Grâce à la méthodologie analytique adoptée qui a fait appel à différentes techniques de caractérisation, telles que la chromatographie d'exclusion stérique, la chromatographie liquide haute performance à polarité de phases inversée, la spectroscopie infra rouge à transformée de Fourier, la microscopie à force atomique et les mesures d'angles de contact, nous avons pu mettre en évidence différents types de modifications dans le volume et sur la surface du matériau après stérilisation ainsi qu'après vieillissement. La modification principale du dans la masse du matériau, observée à la dose réglementaire de stérilisation (25 kGy), est la scission des chaînes du polymère, qui s'accompagne de la création de composés de faible masse molaire, donc de migrants potentiels risquant d'influencer la sécurité d'emploi des COC. En effet, certains de ces composés ont été retrouvés avec une concentration relativement importante dans les solutions de mise en contact avec les COC stérilisés, et notamment en solution aqueuse. Toutefois, l'étude préliminaire de toxicité a montré l'absence de cytotoxicité des extractibles obtenus à la dose de la stérilisation.Les modifications relatives à la surface des COC radio-stérilisés sont, quant à elles, de deux natures : physique avec une augmentation de la rugosité de surface et chimique avec la formation de produits d'oxydation polaires ; ces deux types de modifications conduisent à l'augmentation de la mouillabilité de surface. Cependant dans certains cas, notamment après vieillissement, ces modifications sont relativement faibles, même à des doses supérieures à celle préconisée pour la stérilisation, ce qui peut être corrélé à l'absence de l'effet de l'irradiation sur le comportement des COC vis-à-vis des solutions médicamenteuses. En effet, aucune variation de la sorption des principes actifs choisis n'a été montrée entre les COC irradiés et non irradiés vieillis.
66

Analyse simultanée des hormones stéroïdiennes et leurs formes chimiques dans les matrices d'eau et d'urine par SPE-LC-MS/MS en ligne

Clemente Naldi, Amanda 12 1900 (has links)
No description available.
67

Développement de méthodologies analytiques pour l'étude de la migration depuis des contenants en matière plastique prévus pour des applications pharmaceutiques vers des solutions aqueuses et des fluides biologiques / Development of analytical methodologies for the migration study from plastic packaging material intended for pharmaceutical applications into aqueous solutions and biological fluids

Pouech, Charlene 02 July 2014 (has links)
Résumé confidentiel / Résumé confidentiel
68

Photochimie et oligomérisation des composés organiques biogéniques en phase aqueuse atmosphérique / Photochemistry and oligomerization of biogenic organic compounds in atmospheric aqueous phase

Renard, Pascal 25 November 2014 (has links)
La pollution atmosphérique liée aux aérosols organiques secondaire (SOA) représente un des enjeux majeurs du XXIème siècle. La photochimie multiphasique des SOA constitue le coeur et l'originalité de cette thèse.Le réacteur photochimique permet de simuler en laboratoire, l'oxydation en phase aqueuse atmosphérique des composés organiques volatils biogéniques (BVOC), et notamment, la méthyl vinyl cétone (MVK), afin d'étudier la formation ces SOA.Nous étudions la réactivité de la MVK en présence de ●OH et sa capacité à oligomériser en fonction des concentrations initiales de MVK, d'oxygène, et de ●OH. Une large stratégie analytique basée sur la chromatographie liquide couplée à la spectrométrie de masse (MS) permet d'identifier des produits de réaction, et d'établir un mécanisme réactionnel, expliquant la formation des oligomères, leurs rendements et leur vieillissement.Les données colligées servent d'entrées à un modèle de boîte multiphasique, afin d'explorer la sensibilité de l'oligomérisation aux conditions atmosphériques.Ensuite, nous comparons la réactivité de la MVK en présence de ●OH à celle induite par la photolyse de l'acide pyruvique; puis nous mesurons la tension de surface engendrée par ces deux systèmes d'oligomères. Enfin, la mobilité ionique couplée à la MS permet d'observer la co-oligomérisation d'une gamme étendue de BVOC en présence de ●OH.L'oligomérisation atmosphérique implique (i) une concentration minimale de précurseurs pouvant être atteinte dans les aérosols humides via la co-oligomérisation; (ii) une réactivité en compétition avec l'oxygène dissous dans la phase aqueuse, et dont la pertinence atmosphérique reste à explorer. / Air pollution caused by secondary organic aerosol (SOA) is one of the major challenges of this century. We focus this thesis on SOA , through an innovative approach, i.e. multiphase photochemistry.The photochemical reactor allows to simulate in laboratory, the atmospheric aqueous phase oxidation of biogenic volatile organic compounds (BVOC) and in particular, methyl vinyl ketone (MVK), and thus, to study SOA.We study the reactivity of MVK in the presence of ●OH and its ability to oligomerize under various initial concentrations of oxygen, MVK and ●OH. A wide analytical strategy based on liquid chromatography-mass spectrometry is used to identify the reaction products, and establish a chemical mechanism. We focus on these oligomers systems, formation, yield and aging. Collected data are used as inputs to a multiphase box model to explore the sensitivity of oligomerization to the variations of physical and chemical atmospheric parameters. The photochemistry of pyruvic acid generates radical chemistry and initiates MVK oligomerization. We closely compare this reaction to MVK ●OH oxidation. Then, we measure the surface activity of both systems. The ability of oligomers to partition to the interface could affect the climate. Finally, we used ion mobility - mass spectrometry to observe ●OH co-oligomerization of a mixture of organic compounds most representative of the atmosphere.Atmospheric oligomerization implies (i) a minimal concentration of precursors that could be reached in wet aerosol via the co-oligomerization; (ii) a reactivity in competition with the addition of the dissolved oxygen, whose the atmospheric relevance remains to be explored.
69

Analyse d’hormones stéroïdiennes par spectrométrie de masse dans les eaux du robinet, de surface et les eaux usées

Goeury, Ken 02 1900 (has links)
Il apparaît au grand jour que de nombreuses substances telles que les perturbateurs endocriniens sont introduites quotidiennement dans l’environnement. Ces molécules organiques bien souvent d’origine anthropique peuvent être employées dans d’innombrables circonstances : pharmaceutique, médecine, agriculture, cosmétique, agroalimentaire pour citer quelques exemples. Parmi ce large panel de composés, se trouvent les hormones stéroïdiennes. Un certain nombre de maladies et de modifications aussi bien comportementales que physiologiques tant chez l’humain que sur la faune aquatique sont attribuées à l’usage et aux rejets chroniques de ces perturbateurs endocriniens. Il est donc indispensable de développer une approche portée sur la prévention et l’étude des niveaux de contamination selon un seul maître-mot : précaution. Dans ce contexte, ce projet de doctorat visait à développer de nouvelles méthodes de détection des hormones stéroïdiennes à niveau ultra-trace dans diverses matrices environnementales. La sélection des composés ciblés dans ce projet s’est basée sur la nouvelle liste de perturbateurs endocriniens prioritaires de l’agence de protection de l’environnement des États-Unis (US EPA), récemment élargie à d’autres classes de substances dont le bisphénol A. Les méthodes analytiques ont été développées non seulement dans l’eau du robinet (EPA 539), mais également dans d’autres matrices plus complexes (eaux de surface, eaux usées). Commune à l’ensemble des procédures testées, la phase de validation analytique a permis de vérifier la conformité avec les exigences de performance de l’EPA. La première méthode mise au point repose sur une pré-concentration rapide de l’échantillon par extraction sur phase solide en ligne (on-line SPE) couplée à la chromatographie liquide à ultra-haute performance (UHPLC) et à la spectrométrie de masse en tandem (MS/MS). La méthode validée présente de nombreux avantages—reproductibilité, automatisation, temps d’analyse minimal, logistique réduite et surtout des limites de détection de 0,10 ng·L-1 à 7,5 ng·L-1 selon les différentes matrices étudiées. Cette méthode apparaît particulièrement adaptée pour la détection des hormones dans les eaux usées, en lien avec les plus fortes concentrations attendues. Cependant, il est apparu pertinent d’améliorer encore la sensibilité des méthodes dans certains contextes, notamment dans le cadre des iv analyses d’eau de surface, compte tenu des critères de qualité applicables. La principale modification fut apportée au niveau de l’extraction et de la purification des échantillons. Amendée à la faveur des différentes matrices, l’étape d’extraction par SPE hors-ligne automatisée (off-line SPE) a permis d’atteindre des limites de détection adéquates variant de 0,010 ng·L-1 à 6,0 ng·L-1 dépendamment de la matrice et du composé. Un aspect original de cette étude a consisté à étudier de façon plus systématique les facteurs de robustesse de la méthode lorsque soumise à certaines variations, tant au niveau de l’analyse instrumentale (phases mobiles, volume d’injection) que des protocoles (emploi de différents agents de conservation, par exemple). L’analyse de la phase dissoute ne saurait être suffisante pour comprendre le devenir environnemental des perturbateurs endocriniens dans les milieux aquatiques, notamment leur distribution. Dans cette optique, la phase particulaire en suspension dans la colonne d’eau (SPM) fut également étudiée après optimisation et validation de la méthode d’extraction. Les limites de détection obtenues étaient comprises entre 0,10 ng/g et 3,0 ng/g, un degré de performance adéquat au regard des teneurs attendues dans l’environnement. De telles méthodes ne trouveraient pas de fondement si elles n’étaient pas employées à l’analyse d’échantillons réels. C’est pourquoi, pour chaque méthode développée, une série d’échantillons d’eau a été analysée pour toutes les matrices étudiées. La quantification des hormones stéroïdiennes a permis de rendre compte des niveaux de concentrations retrouvés dans l’environnement. Une étude saisonnière d’un cours d’eau a également été réalisée durant quatre saisons (hiver, printemps, été et automne) afin d’évaluer les éventuelles variations saisonnières en termes d’occurrence et de concentration. / It is now admitted that many substances such as endocrine disruptors are released daily into the environment. This process can be of natural origin but is predominantly linked to human activity. Endocrine disruptors originate from numerous fields: medicine, agriculture, cosmetics, and the food industry, to name a few. Steroid hormones belong to this wide array of compounds. A significant number of human diseases and behavioral and physiological changes in both humans and aquatic life have been attributed to the use and chronic release of these endocrine disruptors. The effects of such a cocktail of substances are difficult to understand and evaluate. To date, the synergistic mechanisms or the potential cumulative effects are not well known. It remains essential to develop an approach focused on the prevention and the study of contamination levels with one key word in mind: precaution. In this context and aiming to detect steroid hormones in tap water, surface water and wastewater at trace levels, new analytical methods have been developed within the framework of this project. The first method developed is based on high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS / MS). LC-MS/MS hyphenation involved using an electrospray ionization source at atmospheric pressure with heating element (H-ESI). Pre-concentration and purification of the samples were executed by on-line solid phase extraction (on-line SPE). The validated method presents several advantages: reproducibility, automation, minimum analysis time, reduced logistics and above all, detection limits ranging from 0.10 ng·L-1 to 7.5 ng·L-1 considering the different matrices studied. The second approach proposed herein is based on the development of an analysis method allowing lower detection limits compared to the previous workflow. The same detection method was used, but a modification was made to the sample extraction and purification. Allowing for greater pre-concentration than online SPE, manual SPE (off-line SPE) was used in this method. Depending on the particular matrix, the extraction step allowed to reach adequate detection limits for the analysis of environmental aqueous samples: 0.010 ng·L-1 up vi to 6.0 ng·L-1 from the matrix-free sample to the most complex matrices. The use of an automated system also made it possible to make the extraction step robust and reproducible. The analysis of the dissolved phase of water samples cannot be sufficient to understand and comprehensively assess the contamination of aquatic environments. The particulate phase in suspension in the water column (SPM) was also studied. The extraction method was optimized and validated. Coupled with the previous method of analysis, it was possible to quantify the steroid hormones attached to suspended materials. The obtained detection limits ranged from 0.10 ng/g to 3.0 ng/g dry weight. For each developed method, dissolved phase samples were analyzed for all the studied matrices (tap water, surface water and wastewater). Quantification of steroid hormones allowed the comprehension of concentration levels found in the environment under usual discharge conditions in multiples matrices. A seasonal study of a watercourse was also carried out during the winter, spring, summer and fall seasons to observe possible seasonal variations in terms of occurrence and concentration.
70

Effet de la stérilisation par électrons accélérés sur les COC et sur l'impact des interactions avec des molécules actives / Effect of electron beam radio-sterilization on cyclo olefin copolymers and its impact on the interactions with active molecules

Barakat, Hala 24 January 2013 (has links)
L’objectif de ce travail de thèse était d’étudier l’effet de la stérilisation par électrons accélérés sur les copolymères d’oléfines cycliques (COC), utilisés comme conditionnement de produits pharmaceutiques, ainsi que son impact sur les interactions avec des formulations pharmaceutiques. Grâce à la méthodologie analytique adoptée qui a fait appel à différentes techniques de caractérisation, telles que la chromatographie d’exclusion stérique, la chromatographie liquide haute performance à polarité de phases inversée, la spectroscopie infra rouge à transformée de Fourier, la microscopie à force atomique et les mesures d’angles de contact, nous avons pu mettre en évidence différents types de modifications dans le volume et sur la surface du matériau après stérilisation ainsi qu’après vieillissement. La modification principale du dans la masse du matériau, observée à la dose réglementaire de stérilisation (25 kGy), est la scission des chaînes du polymère, qui s’accompagne de la création de composés de faible masse molaire, donc de migrants potentiels risquant d’influencer la sécurité d’emploi des COC. En effet, certains de ces composés ont été retrouvés avec une concentration relativement importante dans les solutions de mise en contact avec les COC stérilisés, et notamment en solution aqueuse. Toutefois, l’étude préliminaire de toxicité a montré l’absence de cytotoxicité des extractibles obtenus à la dose de la stérilisation.Les modifications relatives à la surface des COC radio-stérilisés sont, quant à elles, de deux natures : physique avec une augmentation de la rugosité de surface et chimique avec la formation de produits d’oxydation polaires ; ces deux types de modifications conduisent à l’augmentation de la mouillabilité de surface. Cependant dans certains cas, notamment après vieillissement, ces modifications sont relativement faibles, même à des doses supérieures à celle préconisée pour la stérilisation, ce qui peut être corrélé à l’absence de l’effet de l’irradiation sur le comportement des COC vis-à-vis des solutions médicamenteuses. En effet, aucune variation de la sorption des principes actifs choisis n’a été montrée entre les COC irradiés et non irradiés vieillis. / The aim of this work was to study the effect of electron beam radio-sterilization on cyclo olefins copolymers (COC) used as pharmaceutical storage materials, as well as to investigate its impact on the interaction with pharmaceuticals formulations. Due to the analytical methodology used which dealt with different techniques of characterization such as size exclusion chromatography, reversed phase high performance liquid chromatography, Fourier transformed infrared spectroscopy, atomic force microscopy and contact angle measurements, we have been able to put into evidence different kinds of modifications both in the bulk and on the surface of the sterilized material and also after ageing.The principal modification of material’s bulk, observed at the recommended dose for sterilization (25 kGy), was polymer chains scissions, accompanied with creation of low molecular weight compounds, that are potentials migrants that risk to affect the safe use of COC. Indeed, some of these compounds have been found with a relatively important concentration in the solutions where sterilized COC was stored, especially in aqueous solutions. However, the preliminary study of toxicity has shown the absence of cytotoxicity of the extractables obtained at the sterilization dose.Surface modifications of radio-sterilized COC are of two types: a physical one, with an increase of the surface’s roughness and a chemical one with the formation of polar oxidation products; these two modifications result in an increase of surface’s wettability that may be important. However, in some cases such as for aged samples, these modifications are relatively weak even at doses higher than the one recommended for sterilization, which can explain the absence of the effect of radiation on the behavior of COC towards drug solutions. Indeed, no variation of drug sorption has been observed between aged COC irradiated and none irradiated.

Page generated in 0.0598 seconds