Spelling suggestions: "subject:"compositeresin"" "subject:"compositesin""
91 |
Análise "in vitro" da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradoras /Calixto, Abraham Lincoln. January 2003 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Paulo Sergio Quagliato / Banca: João Carlos Gomes / Resumo: O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below) / Doutor
|
92 |
Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura /Mazur, Rui Fernando. January 2003 (has links)
Orientador: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Welingtom Dinelli / Banca: Rodrigo Nunes Rached / Banca: Paulo Sérgio Quagliatto / Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below). / Doutor
|
93 |
Avaliação da efetividade da fotoativação de dois materiais resinosos com diferentes fontes de luz, por meio da microdureza Knoop, resistência à compressão, resistência flexural e caracterização dos materiais / Evaluation of the effect of the light source on the photo polymerization of two resin material by the Knoop microhardness, compressive strength, flexural strength and material characterizationCecy Martins Silva 15 September 2006 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / O objetivo deste trabalho foi avaliar o efeito de um diodo emissor de luz (LED) Smart Lite PS (Dentsply) e da lâmpada halógena convencional Curing Light XL 3000 (3M) na efetividade de polimerização do compômero Dyract Ap (Dentsply) e da resina composta TPH Spectrum (Dentsply) por meio de testes de microdureza Knoop, resistência à compressão e resistência flexural e caracterização dos materiais. Foram confeccionadas 100 amostras e divididas em 12 grupos de acordo com o teste aplicado, a luz de polimerização e o material utilizado. A lâmpada halógena convencional selecionada, Curing Light XL 3000 (3M), tinha intensidade de 470mW/cm2 e comprimento de onda entre 400 e 510nm; o LED Smart Lite PS (Dentsply) tinha intensidade de 950mW/cm2 e comprimento de onda entre 450 e 490nm. O tempo de fotopolimerização para cada incremento com 2mm de espessura foi de 40 s. para a lâmpada halógena convencional e 10 s. para o LED. Para os testes de microdureza Knoop foram confeccionadas 20 amostras numa matriz cilíndrica com 8,0mm de diâmetro e 2,0mm de altura. As leituras da microdureza foram realizadas nas superfícies superiores e inferiores das amostras utilizando um microdurômetro Micromet 2003, com uma carga de 50 gf por 15 s. Para o teste de resistência à compressão foram confeccionadas 40 amostras numa matriz cilíndrica com 4,0mm de diâmetro e 8,0mm de altura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 500Kgf e velocidade de carregamento de 0,5 mm/min. Para o teste de resistência flexural foram construídas 40 amostras numa matriz em forma de caixa com 25,0mm de comprimento, 2,0mm de altura e 2,0mm de largura. A resistência foi medida na máquina de teste universal de ensaios Emic DL 10.000 com uma célula de carga 50Kgf e velocidade de carregamento de 0,5 mm/min. Cada material foi caracterizado pela termogravimetria, espectrometria no infravermelho, espectrometria de ressonância magnética nuclear, teor de cinzas, fluorescência de raios-X e microscopia eletrônica de varredura. Os resultados foram tratados por ANOVA e teste de SNK (p<0,05). Os resultados de microdureza Knoop, resistência à compressão e resistência flexural providos pela luz halógena foram melhores que os dos LED. A resina composta apresentou melhor performance que o compômero em todos os testes. / The goal of this work was to evaluate the effects of the blue light emitting diodes (LEDs) Smart Lite PS (Dentsply) and the conventional halogen lamp Curing Light XL 3000 (3M) on the polymerization effectiveness of the Dyract Ap compomer (Dentsply) and the TPH Spectrum composite resin (Dentsply) by the Knoop microhardness, compressive strength, flexural strength and material characterization tests. A hundred samples were prepared and divided into 12 groups according to the test applied, the polymerization light and the material. The conventional halogen lamp light had power of 470mW/cm and wavelength between 400 and 510nm; the LED light had power of 950mW/cm and wavelength between 450 and 490nm. The polymerization time for each material 2mm buildup was 40 seconds for the conventional halogen lamp and 10 seconds for LED. For the Knoop microhardness tests the 20 samples were cylinder shaped, 8mm diameter and 2mm height. The hardness was read in the upper and lower side of the samples by a micrometer (Micromet 2003), with 50 gf for 15 seconds. For the compressive strength test the 40 samples were cylinder shaped, 4mm diameter and 8mm height. The strength was measured in an universal testing machine Emic DL 10.000 with 500Kgf and cross-head speed of 0,5 mm/min. For the flexural strength test the 40 samples were box shaped, 25mm length, 2mm width and 2mm height. The strength was measured in an universal testing machine Emic DL 10.000 machine with 50Kgf and cross-head speed of 0,5 mm/min. Each material was characterized by Thermogravimetry, FT-IR analysis, Nuclear Magnetic Resonance, Ash Content Test, X-Ray Fluorescence and Scanning Electron Microscopy. The results were treated by ANOVA and SNK tests (p<0,05). The Knoop microhardness, compressive strength and flexural strength results provided by the halogen light lamp were better than the LED ones. The composite resin performed better than the compomer in all mechanical tests.
|
94 |
Avaliação da influência do material de confecção das matrizes no teste de conversão monomérica por espectrometria no infravermelho de um compósito / Evaluation of the influence of the mould material on the degree of conversion by infrared spectroscopy of a compositeAdriana Riedlinger Mont'Alverne Bordalo 18 December 2007 (has links)
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante. / This study was undertaken in order to determine, in vitro, the influence of mould material by the degree of conversion in a composite, and assess which of the materials tested was more akin to an array of dentin. The assessment was made by examining the degree of conversion (DC). Three bipartite moulds were made of black Teflon, white Teflon and stainless steel. All of them had 10 mm of diameter and 2 mm of deep. To the control group it was used a bovine central incisor, which had its buccal face leveled off in a sander under refrigeration with help of sandpaper 800. After that, this tooth was prepared in high speed with a diamond bur 2294 (KG Sorensen). This bur is proper for preparing standardized cavities for laboratories tests, and has a flat end with stop. A cavity of 2 mm of deep for 9 mm of diameter was obtained by a low speed that made the walls finished. With a cylindrical carbide bur 2056 (KG Sorensen), through the tooth lingual, a penetration was made until an extremely thin wall of dentin was obtained. Thus, with a needle, a little perforation was made in the center of this dentin. The specimens were made dispensed the restorative material on a single increment. A strip of cellulose was placed on top and a glass slab was pressed on the top. The material was cured during 40 seconds by halogen light, Optilux 501 (Demetron), with 500 mW/cm. Immediately, after cured, the specimens were submitted, on the top and on the bottom, to analyze their degree of conversion by FTIR. For the uncured composite was used the technique of the film leaked and for the cured composite, the technique of the potassium bromide tablet (KBr). Five specimens of each group had been confectioned. In each group, the bottom and top composite of the samples was worn out until if getting of 1,5 the 2,0 mg of dust and mixed with 70 mg of KBr, for attainment of the tablet of KBr. The analysis of FTIR was made. The absorptions selected for the calculation had been 1610 cm-1 and 1637 cm-1, the peaks of the specters of the linkings of aromatical and alifatic carbons, respectively. The data had been treated statistical. It could be concluded that the groups of black Teflon, white Teflon and stainless steel had not presented differences between the degree of conversion of the top and the bottom, whereas the group of the dentin presented greater conversion of the top. Comparing the moulds between them, it could be noticed that in the top, the DC of the bovine tooth is greater that the DC of the stainless steel and black Teflon, the DC of white Teflon is greater that the DC of the stainless steel and black Teflon. The top of the groups of bovine tooth and black teflon been similar. In the bottoms of the specimens, it did not have significant difference between the tested groups. In accordance with the results gotten in the experiment, could be concluded that in the groups of black Teflon, white Teflon and stainless steel it did not have difference between 0 and 2 mm, that is, top and bottom, its means that the material of mould confection did not influence the degree of conversion of the composite. Already for the group of the dentin, the top presented value of bigger conversion, showing that, in this in case that, the material of the matrix intervened with the DC. It can also be perceived that a trend of the white Teflon mould to resemble more the dentin mould, therefore was the only group that presented similarity in the values of DC in the top of the samples. However analyzing the bottom of the samples, all the groups had values of the degree of conversion without significant difference.
|
95 |
Avaliação quantitativa e qualitativa da rugosidade superficial de resinas compostas com nanopartículas submetidas a diferentes métodos de polimentoCosta, Catharina Simoni da January 2013 (has links)
Introdução: Existe no mercado odontológico muitos instrumentos rotatórios para serem utilizados no polimento final de uma restauração adesiva. Como são muitas as opções, e um mesmo fabricante tem mais de um tipo de instrumento rotatório para realizar a finalização da restauração, não se estabelece uma conduta única que determine qual o instrumento utilizar para resinas compostas que contenham nanopartículas. Objetivo: Avaliar, in vitro, o efeito de dois diferentes sistemas de polimento, baseados em um e multi etapas, sobre a qualidade e rugosidade da superfície de duas resinas com nanopartículas. Materiais e métodos: As amostras foram confeccionadas com resina nanoparticulada Filtek Z 350 XT (3M ESPE) e nanohíbrida Tetric N Ceran (Ivoclar Vivadent ). As amostras foram confeccionadas em moldes cilíndricos medindo 3 mm X 6 mm. Um único operador executou todos os procedimentos. Cada grupo foi composto por 20 amostras: 1) ZXT-Controle (sem polimento); 2)TNC-Controle (sem polimento); 3) ZXT+ Sof-Lex (seqüência Laranja – fina e superfina); 4) ZXT+ Optrapol; 5) TNC+ Optrapol ; 6) TNC+ Sof- Lex (seqüência Laranja – fina e superfina ). A rugosidade de superfície foi avaliada com rugosímetro (Ra), MEV e AFM. Estatística: Para análise das médias de rugosidade Ra (μm), os dados foram submetidos aos testes de normalidade de ANOVA, ao nível de significância de 5%. Uma vez verificada a distribuição normal dos resultados, estes foram submetidos à análise de variância, seguida pelo teste de Tukey com nível de significância de 5%. Resultados: As análises qualitativas e quantitativas mostraram que as resinas polidas com Optrapol apresentaram maior rugosidade superficial e o polimento com Sof-Lex não mostrou diferença estatística entre as resinas testadas. A menor rugosidade foi obtida com os grupos controle, sem diferença estatística entre as resinas. Conclusão: Optrapol promove maior rugosidade nas resinas testadas, e ZXT apresentou maior rugosidade. O polimento com Soft-Lex não mostrou diferenças estatisticamente significantes entre as resinas testadas. A rugosidade superficial das resinas foi menor com TNC, quando comparado com Optrapol. A menor rugosidade de superfície obtida foi pelo grupo controle. / Introduction: There are many tools on the market dental rotary for use in polishing of a restoration adhesive. As there are many choices, and the same manufacturer have more than one type of rotary apparatus of restoration, does not establish a single conduit to determine which tool to use composites containing nanoparticles. Objective: To evaluate, in vitro, the effect of two different polishing systems, based on a multi steps and on the quality and surface roughness of two composites nanoparticles. Materials and methods: The samples were prepared with nanofilled material resin Filtek Z 350 XT (3M ESPE) and nanohíbrid Tetric N Ceran (Ivoclar Vivadent). The samples were made in cylindrical molds measuring 3 mm X 6 mm. A single operator executed all procedures. Each group consisted of 20 samples: 1) ZXT-control (without polishing); TNC-2) control (without polishing); 3) ZXT Sof-Lex (Orange – fine and Superfine); 4) ZXT Optrapol; 5) TNC Optrapol; 6) TNC Sof-Lex (Orange – fine and Superfine). The surface roughness was assessed with porfilometry (Ra), SEM and AFM. Statistical analyses: For analysis of mean roughness Ra (um), the data were tested for normality of ANOVA, at a significance level of 5%. Once verified the normal distribution of the results, they were subjected to analysis of variance followed by Tukey's test with a significance level of 5%. Results: The qualitative and quantitative analyzes showed that resins polished with Optrapol showed higher surface roughness and polishing with Sof-Lex showed no statistical difference between the resins tested. The lowest roughness was obtained with the control group, with no statistical difference between the resins. Conclusion: Optrapol promotes greater roughness in the resins tested, and ZXT showed higher roughness. Polishing with Soft-Lex showed no statistically significant differences between the tested resins. The surface roughness of the resins with TNC was lower when compared with Optrapol. The lowest surface roughness was obtained by the control group.
|
96 |
Ablação de resinas compostas com laser de Er:YAG sob diferentes fluxos de água / Er:YAG laser ablation of composite resin different water flowsLilian Tan Moriyama 22 March 2006 (has links)
O uso do laser na Odontologia é bastante variado. O laser de Er:YAG tem se mostrado como um instrumento eficiente na remoção de restaurações de resina composta. É sabido que a falta ou excesso de água podem atrapalhar o processo de ablação com este laser, pois seu comprimento de onda de emissão (2940nm) coincide com o principal pico de absorção da água. Este trabalho tem como finalidade investigar o efeito da variação do fluxo de água, de forma controlada, no processo de ablação de resina composta restauradora com laser de Er:YAG, através da avaliação dos aspectos morfológicos da superfície irradiada sob microscopia eletrônica de varredura, da quantidade de material removido e das alterações de temperatura durante a irradiação na presença e na ausência de água. Os experimentos foram conduzidos utilizando um sistema laser de Er:YAG, pulsado no regime de microssegundos, já de uso clínico odontológico. Foram confeccionadas amostras em resina composta do tipo híbrida e diferentes condições de trabalho foram utilizadas para analisar a real influência da água: diferentes energias por pulso (100, 200, 300 e 400mJ), freqüências (5Hz, 10Hz e 15Hz) e fluxos de água (zero, 0.01, 0.06, 0.23, 0.32, 0.64 e 0.87ml/s). Os resultados mostram que o fluxo de água influencia no mecanismo de ablação de resinas compostas com laser de Er:YAG, tornando a ablação mais eficiente. Há dois mecanismos envolvidos neste processo: a vaporização explosiva e a interação termomecânica mediada por água, onde há ejeção hidrodinâmica das partículas. A água, além de resfriar o campo de interação, evita a fusão e ressolidificação e facilita a ablação, tornando-a mais precisa. / Laser in Dentistry is used in several ways. Er:YAG laser has proved to be an efficient tool for removal of composite resin restoration. It is well-known that the lack or the excess of water may make difficulties for the ablation process with this laser, due to its emission wavelength (2940nm) to coincide with the main water absorption peak. The aim of the present work is to investigate the effect of water flow rate variation on composite resin ablation process using Er:YAG laser, through the evaluation of morphological aspects of irradiated surface under scanning electron microscopy; the amount of removed material and the temperature variations during the irradiation with and without water. The experiments were performed using a microsecond pulsed Er:YAG laser system, that is already used in clinical Dentistry. Hybrid composite resin samples were prepared and different conditions of irradiation were used to analyze water real influence: different energy per pulse (100, 200, 300 e 400mJ), pulse repetition rate (5Hz, 10Hz e 15Hz) and water flow rate (zero, 0.01, 0.06, 0.23, 0.32, 0.64 e 0.87ml/s). The results show that the water flow rate influences the ablation mechanism of composite resins using Er:YAG laser, providing a more efficient ablation. There are two mechanisms involved in this process: the explosive vaporization and the thermal-mechanical interaction through water, on which particles are ejected hydrodynamically. Water not only cools the interaction site, but also prevent from melting and resolidification and provides an easier and more precise ablation.
|
97 |
Estudo in vitro do efeito de unidades fotoativadoras com diferentes comprimentos de onda na dureza (por meio de micro e ultramicroendentação) e módulo de elasticidade de uma resina composta nanohíbrida / Effect of light sources with different wavelengths in micro and ultramicrohardness and elastic modulus of a nanohybrid composite resin. An in vitro studyJesuina Lamartine Nogueira Araujo 04 June 2013 (has links)
Este trabalho avaliou in vitro a dureza e módulo de elasticidade de uma resina composta nanohíbrida (Tetric N-Ceram/Ivoclair-Vivadent) com diferentes cores, fotoativada por duas unidades com diferentes comprimentos de onda em 3 espessuras (1, 2 e 3mm) comparadas à partir da superfície irradiada (0mm). Os espécimes foram divididos em grupos (n=5): microdureza Knoop-KHN, ultramicrodureza-DUH e módulo de elasticidade-ME, cor (A2 e Bleach-M(BM), fotoativador LEDazul (Elipar Freeligth2/3M(750mW/25s/430-480nm(FL) e LEDazul/violeta Bluephase/Ivoclar/Vivadent (1200mW/cm²/15s/380-515nm(B15) e 30s(B30). Os espécimes foram armazenados por 24h/37ºC. Os ensaios de KHN foram realizados no HMV-2000/Shimadzu, com carga de 25gf/40s, e de DUH e ME no DUH 211S/Shimadzu com força de 10mN e tempo de espera de 0s. Foram realizadas 5 endentações na superfície irradiada (0mm) e na base das amostras (1, 2 e 3mm). A análise estatística foi realizada por ANOVA, Tukey e correlação de Pearson (p<0,01%). O teste de Pearson mostrou haver correlação direta entre a KHN e a DUH. A fonte FL promoveu maiores valores de KHN e de DUH para as duas resinas testadas; enquanto que a fonte B15, promoveu o maior valor de ME. Quanto às espessuras, 0 e 1mm apresentaram maiores valores de KHN e de DUH, e menores de ME que as espessuras de 2 e 3mm. A cor A2 apresentou maior valor de KHN e DUH e menor ME que a cor Bleach-M. Assim, de acordo com a metodologia proposta e os resultados apresentados pode-se concluir que apesar de a luz LEDazul/violeta propor uma maior eficácia na polimerização de resinas de cor clara, no tocante às propriedades avaliadas isso não foi verificado. / This study evaluated in vitro the hardness (micro and ultramicro) and elastic modulus of a nanohybrid composite resin (Tetric N-Ceram/Ivoclar-Vivadent) with different colors, light sources and thickness. The specimens were divided into groups (n=5): KHN-Knoop microhardness, DUH-nanohardness and ME-elastic modulus; colors: A2 and Bleach-M (BM); light sources: LEDblue Elipar Free light 2/3M-ESPE (750mW/cm²/ 25s/430-480nm- (FL)), LEDblue/violet Bluephase/Ivoclar-Vivadent (1.200mw/cm²/15s/380-515nm) (B15) and 30s (B30); thickness: 1mm, 2mm and 3mm, compared to the irradiated surface (0mm). Specimens were stored dry for 24hours at 37ºC after photo curing. Assays were performed at KHN in HMV-2000/ Shimadzu with load of 25gf at 40s and DUH/ME in DUH 211S/Shimadzu with force of 10mN and no hold time (0s). 5 indentations of each test were made in the surfaces opposites to the photo curing. A statistical analysis was performed by ANOVA, Tukey and Pearson correlation (p<0.01%). Pearsons Test showed a direct correlation between KHN and DUH. Comparison between KHN and ME in the studied resins indicated that the light source FL promoted higher values of KHN and DUH to both resins tested, whereas the B15 light source promoted the higher ME value. Regarding thickness 0mm and 1mm showed higher KHN and DUH and lower ME than 2 and 3mm thickness. A2 color showed higher KHN and DUH and lower ME than BM. Thus, according to the proposed methods and the presented results, the LEDblue/violet was not better for curing the light color of the nanohybrid resin, than LEDblue.
|
98 |
Avaliação quantitativa e qualitativa da rugosidade superficial de resinas compostas com nanopartículas submetidas a diferentes métodos de polimentoCosta, Catharina Simoni da January 2013 (has links)
Introdução: Existe no mercado odontológico muitos instrumentos rotatórios para serem utilizados no polimento final de uma restauração adesiva. Como são muitas as opções, e um mesmo fabricante tem mais de um tipo de instrumento rotatório para realizar a finalização da restauração, não se estabelece uma conduta única que determine qual o instrumento utilizar para resinas compostas que contenham nanopartículas. Objetivo: Avaliar, in vitro, o efeito de dois diferentes sistemas de polimento, baseados em um e multi etapas, sobre a qualidade e rugosidade da superfície de duas resinas com nanopartículas. Materiais e métodos: As amostras foram confeccionadas com resina nanoparticulada Filtek Z 350 XT (3M ESPE) e nanohíbrida Tetric N Ceran (Ivoclar Vivadent ). As amostras foram confeccionadas em moldes cilíndricos medindo 3 mm X 6 mm. Um único operador executou todos os procedimentos. Cada grupo foi composto por 20 amostras: 1) ZXT-Controle (sem polimento); 2)TNC-Controle (sem polimento); 3) ZXT+ Sof-Lex (seqüência Laranja – fina e superfina); 4) ZXT+ Optrapol; 5) TNC+ Optrapol ; 6) TNC+ Sof- Lex (seqüência Laranja – fina e superfina ). A rugosidade de superfície foi avaliada com rugosímetro (Ra), MEV e AFM. Estatística: Para análise das médias de rugosidade Ra (μm), os dados foram submetidos aos testes de normalidade de ANOVA, ao nível de significância de 5%. Uma vez verificada a distribuição normal dos resultados, estes foram submetidos à análise de variância, seguida pelo teste de Tukey com nível de significância de 5%. Resultados: As análises qualitativas e quantitativas mostraram que as resinas polidas com Optrapol apresentaram maior rugosidade superficial e o polimento com Sof-Lex não mostrou diferença estatística entre as resinas testadas. A menor rugosidade foi obtida com os grupos controle, sem diferença estatística entre as resinas. Conclusão: Optrapol promove maior rugosidade nas resinas testadas, e ZXT apresentou maior rugosidade. O polimento com Soft-Lex não mostrou diferenças estatisticamente significantes entre as resinas testadas. A rugosidade superficial das resinas foi menor com TNC, quando comparado com Optrapol. A menor rugosidade de superfície obtida foi pelo grupo controle. / Introduction: There are many tools on the market dental rotary for use in polishing of a restoration adhesive. As there are many choices, and the same manufacturer have more than one type of rotary apparatus of restoration, does not establish a single conduit to determine which tool to use composites containing nanoparticles. Objective: To evaluate, in vitro, the effect of two different polishing systems, based on a multi steps and on the quality and surface roughness of two composites nanoparticles. Materials and methods: The samples were prepared with nanofilled material resin Filtek Z 350 XT (3M ESPE) and nanohíbrid Tetric N Ceran (Ivoclar Vivadent). The samples were made in cylindrical molds measuring 3 mm X 6 mm. A single operator executed all procedures. Each group consisted of 20 samples: 1) ZXT-control (without polishing); TNC-2) control (without polishing); 3) ZXT Sof-Lex (Orange – fine and Superfine); 4) ZXT Optrapol; 5) TNC Optrapol; 6) TNC Sof-Lex (Orange – fine and Superfine). The surface roughness was assessed with porfilometry (Ra), SEM and AFM. Statistical analyses: For analysis of mean roughness Ra (um), the data were tested for normality of ANOVA, at a significance level of 5%. Once verified the normal distribution of the results, they were subjected to analysis of variance followed by Tukey's test with a significance level of 5%. Results: The qualitative and quantitative analyzes showed that resins polished with Optrapol showed higher surface roughness and polishing with Sof-Lex showed no statistical difference between the resins tested. The lowest roughness was obtained with the control group, with no statistical difference between the resins. Conclusion: Optrapol promotes greater roughness in the resins tested, and ZXT showed higher roughness. Polishing with Soft-Lex showed no statistically significant differences between the tested resins. The surface roughness of the resins with TNC was lower when compared with Optrapol. The lowest surface roughness was obtained by the control group.
|
99 |
Avaliação in vitro da liberação de fluoretos de duas resinas compostas modificadas por poliacidos e um ionomerico modificado por resinaMolleri, Roberto Rogerio 14 November 2000 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertaçâo (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T13:31:40Z (GMT). No. of bitstreams: 1
Molleri_RobertoRogerio_M.pdf: 1902314 bytes, checksum: baf7ac5c1ec9610da04287a80787fb87 (MD5)
Previous issue date: 2000 / Resumo: Muitos estudos demonstram a liberação de fluoretos dos cimentos de ionômero de vidro modificados por resina e de resinas compostas modificadas por poliácidos. Os efeitos anticariogênicos dos fluoretos têm levado a sua incorporação em um grande número de materiais dentários. O objetivo deste estudo foi quantificar e comparar in vitro a liberação de fluoretos de três materiais restauradores, duas resinas compostas modificadas por poliácidos, e um cimento de ionômero de vidro modificado por resina, nos períodos de 1,4,7,10,15 e 21 dias. Foram confeccionados cinco corpos-de-prova cilíndricos, com medidas de 3 mm de altura por 6 mm de diâmetro utilizando uma matriz metálica pré-fabricada. Os corpos de prova foram mantidos em recipientes com 20 mL de água destilada e deionizada, na temperatura de 37 graus centígrados. A água foi trocada após cada medição. A análise da água foi realizada por um potenciômetro modelo 720 A, marca Orion (Cambridge, MA, USA), acoplado a um eletrodo seletivo para fluoretos, modelo 9609, marca Orion (Cambridge, MA, USA), que determinou a quantidade de fluoretos em partes por milhão. Os dados foram submetidos à análise de variância e teste de Tukey. O estudo demonstrou o mesmo padrão de liberação de fluoretos para os três materiais, pois todos apresentaram maior liberação nas primeiras 24 horas. Após o décimo dia houve estabilização na liberação para todos os materiais. A liberação de fluoretos nas resinas compostas modificadas por poliácidos se manteve menor e constante, se comparada ao cimento de ionômero de vidro modificado por resina, que apresentou valores médios maiores / Abstract: Many studies have shown the release of fluorides frem resin-modified glass ionomer and polyacid-modified composite resin. The anticariogenic effects ofthe fluoride ions have called for their use in a great number of dental materiais. The aim of this study was to evaluate and compare, in vitro, the fluoride release of three restorative materiais, the polyacid-modified composite resin and a resin-modified glass ionomer, in 1,4, 7, 10, 15, and 21 days. Five cylindrical samples were made, 3 mm high by 6 mm in diameter by using a pre-built metallic matrix. The samples were stored in 20 mL containers in deionized, distilled water, at 37°C. The water was replaced after each measurement. The water analysis was done by an Orion 720 A model potentiometer (Cambridge, MA, USA), attached to an Orion 9609 model selective electrode for fluorides (Cambridge, MA, USA), which determined the amount of fluorides in parts per milion. The study showed the same fluoride release pattern forthe three materiais, as ali ofthem presented a high release in thefirst24 hours. Afterthetenth day, there was a stabilization in the release for ali materials. The fluorides release in the 'polyacid-modified composite resin remained lower and constant, comparing to the resin-modified ionomer glass cement, which showed higher mean values / Mestrado / Mestre em Materiais Dentários
|
100 |
Adaptação marginal e resistencia a fratura de Inlays confeccionados em ceramica e compositos laboratoriaisSoares, Carlos José 12 December 2000 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T18:58:28Z (GMT). No. of bitstreams: 1
Soares_CarlosJose_M.pdf: 18449799 bytes, checksum: 7ca114de2d92eff546a3f14d3186d306 (MD5)
Previous issue date: 2000 / Resumo: A proposta deste estudo foi avaliar a adaptação marginal e a resistência à fratura de "inlays" confeccionados em quatro sistemas restauradores indiretos, porcelana feldspática Duceram LFC (Degussa) e três resinas laboratoriais, Solidex (Shofu), Artg1ass Heraeus Kulzer) e Targis (Ivoclar). Foram selecionados 60 molares inferiores, com dimensões semelhantes, que foram incluídos em cilindros de resina com reprodução do ligamento periodontal. Os dentes receberam preparos MOD com 6 'GRAUS¿ de expulsividade, realizados em aparelho padronizador. Em seguida, foram moldados com silicona por adição e as restaurações confeccionadas seguindo as orientações dos fabricantes. A avaliação da adaptação marginal foi feita em sistema computadorizado de coleta de imagem associado a um aparelho digital de medição. Com aumento de 40x, determinaram-se os pontos de medição, sendo 4 pontos para cada região, eclusal, proximal e cervical e, com aumento de 250X, determinou-se o valor da discrepância marginal, através de um sistema de coordenadas digitais. As restaurações foram fixadas empregando a associação do sistema adesivo Single Bond e o cimento resinoso Rely X (3M) e armazenadas em 100% de umidade a 37° C por 24 horas. As amostras foram então submetidas a um carregamento axial de compressão com velocidade de 0,5 mm/minuto até a completa fratura da restauração. Os dentes fraturados foram analisados, classificando-se o padrão de fratura em cinco níveis: I -fratura isolada da restauração; II - fratura da restauração com pequena porção do dente; III -fratura da restauração com menos da Y2 do dente, sem envolvimento radicular; IV - fratura da restauração com mais da Y2 do dente, sem envolvimento radicular.; V -fratura com envolvimento radicular. A interface de fratura foi analisada por microscopia eletrônica de varredura. Os valores da adaptação marginal foram analisados estatisticamente aplicando a análise de variância segundo o esquema de parcelas subdivididas, sendo os materiais restauradores as parcelas e as regiões, as subparcelas. Verificaram-se diferenças estatisticamente significantes entre as regiões (p=0.0001), independente do tratamento estudado (p= 0.60555) e também entre os materiais restauradores (p= 0.0001). A discrepância marginal encontrada na região oclusal foi estatisticamente inferior à encontrada na região proximal, e esta menor que na região cervical. Entre os materiais restauradores, a adaptação marginal da cerâmica Duceram LFC foi estatisticamente inferior à encontrada para os materiais Solidex, Artglass e Targis em todas as regiões analisadas, não havendo diferenças entre estes. Os valores de resistência à fratura foram submetidos à análise de variância, demonstrando a ocorrência de diferenças estatisticamente significantes entre os materiais restauradores (p= 0,001). O teste de Tukey ('alfa¿= 0,05) foi aplicado, verificando que os dentes restaurados com Duceram LFC (205,44 '+ ou ¿' 39,5IKgf), apresentaram resistência média estatisticamente inferior aos grupos que receberam "inlays" confeccionados com os compósitos Solidex (293,16 '+ ou ¿' 45,86Kgf), Artglass (299,87 '+ ou ¿' 41,08Kgf) e Targis (304,23 '+ ou ¿' 52,52Kgf), não havendo diferenças entre os três compósitos laboratoriais. O padrão de fratura das amostras restauradas com cerâmica foi predominantemente do tipo I e II, por outro lado, as amostras restauradas com compósitos laboratoriais apresentaram padrões de fraturas predominantemente do tipo III, IV e V / Abstract: The aim of this study was to evaluate the marginal adaptation and the fracture strenght of four different inlay indirect restorative systems: feldspathic Duceram LFC (Degussa) and three laboratory resins, Solidex (Shofu), Artglass (Heraeus Kulzer) and Targis (Ivoclar). Sixty inferior molar tetth with similar dimensions were selected and included in resin cylinders, reproducing the periodontal ligaments. Six degree expulsive MOD inlay preparations were realized in a standard cavity preparation equipment. Afterwards, they were molded with polyvinyl siloxane impression and the restorations were prepared following the manufacturer¿s instructions. The marginal adaptation evaluation was realized with an image collector computer system associated with a digital gauging appliance. Four gauging points were established, with a 405 magnification, on the occlusal, proximal and cervical regions. The marginal discrepancy was recorded with a 230X magnification, by means of a digital coordinate system. The inlays were luted with composite resin Relay X (3M), and adhesive system Single Bond (3M) and restored at 37 'DEGREE¿C and 100% humidity for 24 hours. Then, the samples were submitted to an axial compression load on a 0,5mm/minute speed until the complete fracture of the restoration. The fractured teeth were analyzed, and the fracture patterns were established in five levels: I ¿ isolated fracture of the restoration; II ¿ fracture of the restoration with a small part of the tooth; III ¿ fracture of the restoration with less than half of the tooth, without radicular involvement; IV ¿ fracture of more than half of the tooth, without radicular involvement; V ¿ fracture with radicular involvement. The fracture intrface was analyzed with a scanning electron microscope. The marginal adaptation values were statistically analyzed with the subdivided parceks analysis of variance, in which the restorative materials were the parcels, and the regions, the sub-parcels. Statistically significant differences were seen among regions (p=0.0001), not depending on the treatment studied (p=0.60555), and among the restorative materiais (p=0.0001).The marginal discrepancy recorded on the occlusal region was statistically inferior to that recorded on the proximal region, and the latter, smaller than that on the cervical region. Among the restorative materiais, the marginal adaptation of Duceram LFC was statistically inferior to that found for the materiais Solidex, Artglass and Targis, which showed no statistical differences among them. The ftacture strength values were submitted to the ANOVA, which showed statistically significant differences among the restorative materiais (p = 0.001). Tukey test (cx=0.05)was applied, asserting that the teeth restored with Duceram LFC (205,44:t 39,5IKgf) showed statistically inferior values than the other groups which were restored with the resin composites Solidex (293,16:t 45,86 Kgf), Artglass (299,87 :t 41,08Kgf) and Targis (304,23 :t 52,52Kgt). The resin composites revealed no statistically significant differences for the ftacture resistance values. The fracture pattems for the samples restored with porcelain were predominantly type I and fi, whereas the ftacture patterns recorded for the samples restored with indirect composites were mostly type m, IV, V / Mestrado / Dentística / Mestre em Clínica Odontológica
|
Page generated in 0.0695 seconds