• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 400
  • 400
  • 400
  • 200
  • 179
  • 91
  • 63
  • 61
  • 59
  • 54
  • 54
  • 49
  • 46
  • 43
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Influência da presença de materiais metálicos na capacidade diagnóstica de diferentes métodos por imagem - radiografia convencional, radiografia digital e tomografia computadorizada de feixe cônico - investigação in vitro / Influence of the presence of metallic materials in the diagnostic ability of diverse imaging methods - conventional radiograph, digital radiograph and cone-beam computed tomography - in vitro reserach

Liedke, Gabriela Salatino January 2014 (has links)
O objetivo desta tese foi avaliar a interferência da presença de materiais metálicos na imagem radiográfica e tomográfica por meio da análise da adaptação marginal de restaurações e coroas metálicas. Esta investigação resultou em 3 artigos: uma revisão sistemática da literatura para identificar o estado da arte com relação ao uso dos métodos radiográficos; um estudo in vitro comparando o desempenho do filme radiográfico convencional e dos sistemas digitais VistaScan Dürr Dental, Digora Classic Soredex e Express Instrumentarium – com e sem o emprego de filtros para o pós processamento da imagem; e um estudo in vitro avaliando o processamento das imagens da TCFC – utilizando diferentes espessuras de reconstrução. Na revisão sistemática foram incluídos 14 estudos, sendo classificados de baixa ou moderada qualidade, de acordo com os critérios QUADAS de classificação. Na investigação radiográfica (artigo 2), os maiores valores de sensibilidade (0,67 0,83), especificidade (0,81 0,92) e acurácia (0,73 0,86) foram obtidos com radiografias convencionais e imagens digitais originais. Na avaliação tomográfica (artigo 3), os valores da aucROC variaram de 0,60 a 0,72, sendo que o limite inferior do intervalo de confiança mostrou-se abaixo ou muito próximo da linha de referencia. Frente aos resultados, conclui-se que imagens radiográficas originais (convencionais ou digitais) devem ser preferidas para a avaliação de dentes com restaurações metálicas. Quanto à TCFC, mesmo quando se aumenta a espessura de reconstrução da imagem e diminui-se o artefato, ainda assim não há melhora na acurácia do diagnóstico. / The aim of this thesis was to evaluate the interference of the presence of metallic materials on radiographic and tomographic image by assessing misfits tooth and restoration in metal-restored teeth. This investigation resulted in three articles: a systematic review of the literature to identify the state of the art on the use of radiographic methods; an in vitro study comparing the performance of conventional film and digital phosphor plate systems Vistascan Dürr Dental, Digora Classic Soredex and Instrumentarium Express – exported as original images and with the use of post processing filters; and an in vitro study evaluating the post-processing of CBCT images – using diverse reconstruction thicknesses. The systematic review retrived 14 studies, classified as low- / moderate quality based on QUADAS criteria. For radiographic evaluation (article II), higher sensitivity (0.67 0.83), specificity (0.81 0.92) and accuracy (0.73 0.86) values were obtained with conventional and digital original images. For tomographic evaluation (article III), mean aucROC ranged from 0.60 to 0.72, and the analysis of the 95% CI showed the lower bound of the curve bellow or very close to the reference line. Based on the results, it is concluded that original images (conventional or digital) should be preferred for the assessment of teeth with metal restorations. Considering CBCT images, even thought increased reconstruction thickness decreased perceived artifact, it did not improve diagnosis accuracy.
262

Estudo da precocidade diagnóstica dos melanomas cutâneos primários em Porto Alegre por análise de imagem computadorizada

Hampe, Suzana Vozári January 1997 (has links)
Fundamentos: A literatura tem demonstrado que a detecção precoce e a remoção cirúrgica em fases iniciais reduz a mortalidade do melanoma e que, em conseqüência, a identificação do melanoma em fases curáveis deve ser encorajada. Objetivos: O interesse principal do estudo foi conhecer se os melanomas cutâneos, no meio, estão sendo diagnosticados em fases iniciais, através de método reprodutível e armazenável. Metodologia: Foi realizado um estudo transversal com os casos de melanomas cutâneos primários, analisados nos laboratórios de patologia de Porto Alegre, de 1° de janeiro de 1994 a 30 de junho de 1995, a fim de avaliar se os diagnósticos foram realizados em estágios precoces. Os casos foram revisados por três dermatopatologistas, que classificaram quanto ao tipo histológico e quanto ao nível de invasão de Clark. Foi realizado um consenso com pelo menos duas concordâncias. A espessura de Breslow foi considerada fator prognóstico determinante e foi medida através de um sistema de análise de imagem computadorizada, por dois membros da equipe. Resultados: Do total de 279 casos que preencheram os critérios de inclusão, 2,15% eram intraepiteliais. Dos melanomas invasivos, 52% tinham espessura ≤ 1,5 mm. Quando agrupado por sexo e procedência, as mulheres de Porto Alegre, capital do estado do Rio Grande do Sul, tiveram a mais alta taxa de diagnóstico precoce (75% ≤ 1,5 mm). O tronco foi o sítio predominante no homem e freqüente na mulher. O melanoma de espalhamento superficial foi o tipo histológico mais freqüente (80,9%), seguido pelo nodular (10,1%). Para definir os determinantes do diagnóstico precoce, foram realizados cruzamentos simples, dos melanomas intraepiteliais somados aos de espessura <0,76 mm, com o sexo, a idade, a procedência, a situação previdenciária, a região anatômica e o tipo histológico. A análise de variáveis múltiplas demonstrou que apenas o sexo (feminino), o sítio anatômico (outras regiões exceto membros inferiores) e a procedência (Porto Alegre) mostraram-se variáveis independentes para determinar um diagnóstico precoce. A idade ≥ 40 anos apresentou significância próxima ao limite. O tipo histológico foi excluído do modelo, uma vez que gerou instabilidade estatística. Conclusão: Embora o número de casos fosse pequeno, o diagnóstico do melanoma ainda é tardio (52% com até 1,5 mm de espessura). Entretanto, existe um subgrupo de diagnóstico precoce que são mulheres, sobretudo de Porto Alegre, possivelmente por estarem mais atentas e informadas sobre os riscos do melanoma. As mudanças no estilo de vida, nas últimas décadas, provavelmente são responsáveis pela maior incidência no tronco e pela alta freqüência de melanoma de espalhamento superficial encontrada. A análise da espessura tumoral por projeção em tela de computador mostrou-se um recurso auxiliar vantajoso. / Background: Early detection and surgical removal of malignant melanoma has been shown to reduce mortality, therefore identification of primary cutaneous melanoma at early stages should be promptly encouraged. Objectives: The main subject of the study was analyze if cutaneos malignant melanoma have early diagnosis by a computer image analysis system. Methods: A cross-sectional study was performed with the cases of primary cutaneous melanoma, analysed by pathology laboratories in Porto Alegre, from 1st January, 1994 to 30th June, 1995, to determine whether the diagnosis was performed at early stages. Three dermatopathologists reviewed the histological type and Clark’s level of invasion by light microscopy and a consensus was achieved with at least two agreements. Breslow’s thickness was measured by computer analyses image system, by two members of the study. Results: Of a total 279 cases selected, 2,15% were in situ malignant melanoma, 52% of the invasive melanomas showed a thickness of ≤ 1,5 mm. When grouped by gender and citizenship, women from Porto Alegre had the earlier diagnosis (75% ≤1,5 mm). The predominant site in men was the trunk and also very frequent in woman. Superficial spreading melanomas comprised 80,9% of cases, followed by 10,1% nodular. Bivariate analysis was perfomed to define determinants of earlier diagnosis, using in situ and < 0,76 mm thickness cases: gender, age, citizenship, anatomic location, health insurance situation and histological type. Through multivariate analysis only gender (female), anatomic site (other than lower extremities) and citizenship (Porto Alegre) were significant independent determinants, while age ≤ 40 presented a marginal significance. The histological type was excluded from the model since it generated statistical instability. Conclusions: Although the number of cases was small, the diagnosis is still late (52% with ≤1,5 mm). This study identifies a group of patient with early diagnosis: women, mainly from Porto Alegre are probably more aware about risk of melanoma. Lifestyle changes in the last decades could be responsible for the highest incidence of melanomas on the trunk and of the high frequency of superficial spreading malignant melanoma. The computer image analysis system showed to be an advantajous tool for the measurement of tumor thickness.
263

Verificação da conformidade das atuais Heurísticas de usabilidade quando aplicado aos equipamentos médicos de diagnostico por imagem

FERNANDES, Walquir da Silva 30 January 2014 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-05-20T17:36:32Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO WalquirFernandes.pdf: 962005 bytes, checksum: 355a53e7ec6f6ea739aedc953d9d9d07 (MD5) / Made available in DSpace on 2016-05-20T17:36:32Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO WalquirFernandes.pdf: 962005 bytes, checksum: 355a53e7ec6f6ea739aedc953d9d9d07 (MD5) Previous issue date: 2014-01-30 / As avaliações de usabilidade tornaram-se necessárias no desenvolvimento de artefatos digitais. Esse trabalho visou analisar se o principio tradicional de usabilidade se apresenta adequado quando confrontado com as novas heurísticas de usabilidade aplicadas aos equipamentos médicos de diagnóstico por imagem. Foi realizada uma análise crítica das heurísticas de usabilidade atuais, confrontada com as Heurísticas de Nielsen. O resultado foi a elaboração de 10 heurísticas multiplas, resultante da análise de 4 grupos de heurísticas: -Principios do Design Interativo (Tognazzini) -Schneiderman “8 regras de ouro do Design de Interface”. -Principios de Design, segundo Tufte -Heurísticas de Nielsen. Um estudo de caso comparativo foi realizado entre o conjunto de heurísticas múltiplas e as heurísticas de Nielsen, com intuito de atingir o objetivo da pesquisa. / The evaluations of usability have become necessary in the development of digital artifacts. This study aimed to examine whether the traditional principle of usability itself suitable when confronted with new usability heuristics applied to medical diagnostic imaging equipment. A critical analysis of current usability heuristics, compared with the heuristics of Nielsen was performed. The result was the elaboration of 10 multiple heuristics, resulting from the analysis of 4 groups of heuristics: -Principles of Interactive Design (Tognazzini) -Schneiderman "8 Golden Rules of Interface Design". -Principles of Design, according to Tufte -Nielsen heuristics A comparative case study was conducted among the set of multiple heuristics and Nielsen heuristics, in order to achieve the research objective.
264

Ferramenta de comunicação e acesso remoto a imagens medicas / Tool for communication and remote access to medical images

Borges, Carmem Lucia 20 December 2003 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-06T06:58:33Z (GMT). No. of bitstreams: 1 Borges_CarmemLucia_M.pdf: 2608238 bytes, checksum: d1b5e1e569675e0c0e7e6bbedeaae9f1 (MD5) Previous issue date: 2003 / Resumo: O trabalho desta dissertação se baseia no desenvolvimento de uma ferramenta computacional (software) que permite a captação, transmissão, leitura, edição, e armazenamento remoto de dados biomédicos, com critérios de segurança, autenticação,autorização e integridade de dados. Como adicional importante, o software permite o acoplamento de um sistema de controle de serviços remoto. A aplicação segue um modelo de requisição de serviços cliente-servidor, sob uma arquitetura em camadas, escrita na linguagem de programação Java com as seguintes funcionalidades: visualização de imagens médicas (formato DICOM), edição remota de laudos com assinatura digital, armazenamento de dados relativos ao paciente (demográficos e imagens) e transmissão de imagens médicas. Seu objetivo principal é mostrar a possibilidade de edificação de softwares de acesso e controle remoto de dados biomédicos baseados em sistemas de segurança e permissão seletiva / Abstract: This work describes the development of a computational tool (software) that allows acquisition, transmission, reading, edition, and remote storage of biomedical data, following the protocols established for a Virtual Private Network - VPN, implying in security, authentication, authorization and integrity of data. The software allows the coupling of a control system of remote services. The application follows a model of requisition of services customer-server, under an architecture in layers, written in the programming language Java with the following functionalities: visualization of medical images (DICOM format), remote editing of medical findings with digital signature, storage of patient data (demographic and images) and transmission of medical images. Its objective is to show the possibility of construction of software for access and remote control of biomedical data based in security systems and selective permission / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
265

Proposta para implantação de um programa de controle de qualidade de imagem em equipamento de ultra-som modo-B / Proposal to im plement an image quality control in B-mode ultrasound equipment

Zucatti, Glaucia Ribeiro 26 June 2003 (has links)
Orientador: Vera Lucia da Silveira Nantes Button / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e Computação / Made available in DSpace on 2018-08-07T03:52:25Z (GMT). No. of bitstreams: 1 Zucatti_GlauciaRibeiro_M.pdf: 2508491 bytes, checksum: f6ba34520ac2e744607166ba5fb60754 (MD5) Previous issue date: 2003 / Resumo: A necessidade da Garantia da Qualidade do serviço prestado no ambiente hospitalar tem sido enfatizada nas publicações em Engenharia Clínica. Este trabalho tem por objetivo principal o desenvolvimento de um programa de controle de qualidade de imagem aplicado a equipamentos de imagem médica gerada por ultra-som Modo-S, envolvendo a elaboração e aplicação de protocolos que descrevam inspeção física e mecânica e testes de desempenho aplicados a estes equipamentos. Para a realização dos testes de desempenho, utilizamos um phantom que permite a aquisição das seguintes características do equipamento: uniformidade de imagem, profundidade de penetração do campo ultra-sônico, precisão das medidas do sistema, detecção de vazios esféricos, resoluções axial e lateral e zona morta. Os procedimentos adotados para a avaliação destas características foram estabelecidos através da consulta a normas internacionais e outras bibliografias específicas. Estas bibliografias especificam que os controles do equipamento devem ser ajustados da mesma maneira a cada teste, portanto, neste trabalho também foi realizado um estudo que avalia a influência dos controles de ganho geral, faixa dinâmica e ampliação da imagem nos testes de desempenho. Foram avaliados dez equipamentos de dois departamentos de ecografia distintos. Os resultados dos testes de controle de qualidade de imagem demonstram que 60% dos equipamentos analisados apresentaram algum tipo de defeito na inspeção física e mecânica e que 95,83% dos transdutores analisados apresentou algum dos indicadores de qualidade além do limite de tolerância / Abstract: Clinical Engineering publications have emphasized the necessity of quality assurance of the services done in the hospital environment. The objective of this work was to develop an image quality control program to be applied to B-mode ultrasound scanners, which included the development and application of protocols which describe physical and mechanical inspection and performance tests. For the accomplishment of the performance tests, we have used a multipurpose phantom that allowed the evaluation of the following scanners characteristics: uniformity of image, sensibility (depth of the ultrasonic field penetration), precision of the system measurements, detection of spherical voids, axial and lateral resolutions and dead zone. The procedures adopted for the evaluation of these characteristics have been established through the examination of international standards and specialized publications. These bibliographic materials specify that the controls of the equipment must be adjusted in the same way at each test realization; therefore, this work also have carried through a study that evaluated the influence of varying the general gain and dynamic range controls and the magnification (zoom) of the image field view in the performance tests results. The quality control tests results showed that 60% of the evaluated equipments presented some kind of problem in the physical and mechanical inspections, and that 95.83% of the evaluated transducers presented some of the quality pointers values beyond the limit of tolerance / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
266

Avaliação automatica de parametros fisicos de qualidade de imagem em sistemas de radiologia digital odontologica

Albuquerque, Jorge Andre Girão 29 July 2018 (has links)
Orientador : Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T02:59:46Z (GMT). No. of bitstreams: 1 Albuquerque_JorgeAndreGirao_M.pdf: 5796408 bytes, checksum: 09bd57e0a31a84f22f0e6c4d5ab05252 (MD5) Previous issue date: 2001 / Mestrado
267

Incidência de lesão renal aguda e o uso de contraste endovenoso: estudo retrospectivo

Coser, Thyago Anzolin 22 May 2018 (has links)
No description available.
268

Registro de imagens 3D do cerebro humano / 3D image registration of the human brain

Favretto, Fernanda Oliveira 13 August 2018 (has links)
Orientador: Alexandre Xavier Falcão / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Computação / Made available in DSpace on 2018-08-13T10:55:58Z (GMT). No. of bitstreams: 1 Favretto_FernandaOliveira_M.pdf: 1878530 bytes, checksum: b516fce053de83b3dbd32fa789dcb9c9 (MD5) Previous issue date: 2009 / Resumo: O registro de imagens é o processo que alinha duas ou mais imagens em um mesmo sistema de coordenadas espaciais [31]. Na área de Imagens Médicas, o problema de registro de imagens tem muitas aplicações permitindo, por exemplo, a análise da variação de fenômenos e estruturas anatômicas ao longo do tempo, pelo registro de imagens de uma mesma modalidade obtidas em diferentes instantes de tempo; ou o estudo das informações anatômicas e fisiológicas combinadas para uma dada estrutura fenômeno, pelo registro de imagens obtidas por modalidades diferentes. O objetivo deste trabalho é o desenvolvimento de uma técnica de registro para imagens tridimensionais do cérebro humano, cuja motivação é o estudo comparativo de imagens de Ressonância Magnética pré- e pós-operatórias do cérebro de pacientes de epilepsia. Um estudo recente [80] tem observado que nos casos em que houve crises recorrentes, após a remoção cirúrgica do foco da crise, os pacientes apresentaram alterações nas substâncias cinza e branca do cérebro. O registro das imagens pré- e pós- operatórias desses pacientes permite a análise dessas alterações. Foi desenvolvida uma técnica de registro rígido que realiza o alinhamento de imagens 3D de forma automática, rápida e precisa. O método baseia-se no casamento das linhas de watershed marcador de cinza extraídas da imagem móvel com uma imagem de borda realçada pelo gradiente morfológico da imagem fixa. A busca dos parâmetros de rotação e translação que compõem a função de mapeamento é feita através de uma técnica proposta neste trabalho, denominada Descendente de Gradiente em Múltiplas Escalas (MSGD) - um variante do tradicional método de Descendente de Gradiente - a qual permite passos de tamanhos escalonados dos vetores de gradiente, evitando mínimos locais indesejáveis e convergindo para o ótimo desejado mais rapidamente. O método foi avaliado em imagens 3D de ressonância magnética do cérebro humano ponderadas em T1 e obteve bons resultados. Os experimentos envolveram 2 bases de dados. A primeira base é a base de dados de controle, composta por 200 pares de imagens, onde o registro foi realizado em aproxidamente 45s e obteve erro médio de rotação de 0, 06?, 0, 08? e 0, 08? com desvio padrão de 0, 06, 0, 25 e 0, 08 nos eixos X, Y e Z, respectivamente, e erro médio de translação de 1, 67mm, 1, 55mm e 2, 27mm com desvio padrão de 1, 83, 1, 45 e 2, 27 nos eixos X, Y e Z, respectivamente. A segunda base foi uma base de dados clínicos, composta por imagens pré- e pós-operatórias de pacientes com epilepsia, que comprovou a eficácia do método em dados clínicos reais. Também foram desenvolvidas duas técnicas de visualização do registro, uma delas baseada no mosaico das imagens registradas e a outra que combina as imagens em um único volume colorido, onde as alterações de tecidos são identificadas pelas cores vermelha e verde. Portanto, as principais contribuições deste trabalho são: uma metodologia para o registro, que envolve combinação eficiente de características, métrica de similaridade e estratégia de busca; a estratégia MSGD que se mostrou promissora para outros problemas de otimização; e uma técnica de visualização das imagens registradas na forma de um volume colorido. / Abstract: Image Registration is the process that aligns two or more images in a common reference system of spacial coordinates [31]. It is an important problem with several applications in Medical Imaging, enabling, for instance, the analysis of changes in anatomy along time by the registration of images from the same modality, and the study of combined anatomic and physiologic data by the registration of images from different modalities. The objective of this work is the development of a registration method for 3D images of the human brain, and the motivation is a comparative study of pre and post-surgical images from epilepsy patients. A recent study [80] has observed that some pacients, who did not cease the seizures after surgery, presented variations in their brain tissues. The registration of pre and post-surgical images enables the analysis of these tissue's variations. We developed a rigid registration method that aligns 3D images in a fast, automatic and accurate way. The method is based on the matching between watershed lines extrated from a source image and a morphological gradient image from the target image. The search for the parameters of rotation and translation that compose the mapping function is done by a techinique proposed in this work, named Multi-Scale Gradient Descent - a variant of the tradicional method Gradient Descent - which enables gradient's vectors with scaled magnitudes, avoiding undesirable local minima and fastly converging to the desired optimum. The method was evaluated on 3D T1-weighted Magnetic Ressonance Images of the human brain. The experiments used 2 data bases: a control data base, composed by 200 pairs of images, in which the method took approximately 45s and acceptable results; and a data base of patients, composed by pre- and post-surgical images, demonstrating the effectiveness of the method for real data. We have also developed visualization techiniques for the registred images: the checkerboard image, that alternates the target and registered source in a checkerboard pattern, allowing the user to inspect the correctness, coherence and continuity of the registration; and the colorized image, that combines the target and registered source images in a single colorized volume, such that the alterations of the tissues can be identified by the red and green colors. Therefore, the main contributions of this work are: a 3D registration methodology, that involves an effective combination of feature selection, similarity measure and search strategy; a search strategy, MSGD, that seems to be promissing for other optimization problems; and a visualization techinique that uses a colorized volume to combine the registered images. / Mestrado / Processamento e Analise de Imagens / Mestre em Ciência da Computação
269

Aplicação do recurso de subtração radiografica digital na avaliação da região perimplantar

Bittar-Cortez, Juliana Araujo 02 February 2005 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T19:27:31Z (GMT). No. of bitstreams: 1 Bittar-Cortez_JulianaAraujo_M.pdf: 3295326 bytes, checksum: 3905a9f6f1bc2ee984cad244a6df872b (MD5) Previous issue date: 2005 / Resumo: O exame radiográfico após a instalação de implantes endósseos é um importante meio auxiliar de diagnóstico para se avaliar as alterações no tecido ósseo adjacente, pois durante as fases de reparo e remodelação, no primeiro ano após a implantação ocorre uma redução do osso marginal. Foi proposto investigar o uso da subtração radiográfica digital na avaliação da região perimplantar em um estudo in vivo. Trinta e quatro pacientes foram monitorados através de radiografias periapicais convencionais padronizadas, no primeiro acompanhamento pósoperatório após a cirurgia para instalação de implantes endósseos e quatro meses após, antes da segunda fase cirúrgica, ao final do período de remodelação óssea. As radiografias foram digitalizadas e imagens de subtração radiográfica digital foram criadas por meio de um programa de computador denominado EMAGO. Os dois tipos de imagens, digitalizadas e subtração radiográfica digital, foram comparadas quantitativamente a partir de medidas de densidade óssea, obtidas por meio do histograma de uma área selecionada e por meio de medidas lineares da altura óssea presente avaliando também a reprodutibilidade interobservadores. Dentro das condições deste estudo, concluiu-se que a subtração radiográfica digital tem uma capacidade de diagnóstico semelhante à imagem digitalizada convencional na avaliação de densidade óssea, entretanto, medidas de altura óssea podem ter valores mais próximos do real utilizando imagens de subtração, mas essas medidas apresentam uma variabilidade inter-observadores / Abstract: Radiographic evaluation in connection with implant installation is an important means of diagnosing changes in bone tissue around the implant, where during the healing and the early remodeling phases, a slight reduction of the marginal bone height occurs in the first year after implant placement. The proposition for this research was to validate the use of the digital subtractionradiography in the perimplant region assessment in an in vivo study. Thirty four patients were monitored by standardized periapical conventional radiography in thefirst postoperative follow-up after surgery for implant placement and four months later, prior to the second-stage surgery at the end of the healing period. The radiographs were digitized and digital subtraction radiography was created by means of EMAGO software. The two types of images, digitized and digitalsubtraction radiography, were compared quantitatively by measuring bone density of a selected area by the histogram and by assessing bone height with linear measurements and also evaluating the reproducible inter-observers. Within the limits of this study, it was concluded that digital subtraction radiography has similar diagnostic performance to those of conventional digitized radiography in evaluating bone density however, bone height can be more precisely assessed with the subtraction images but the measurements has an inter-observers variability / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
270

Radiografia panorâmica e tomografia cone beam: Análise de tumores dos maxilares / Panoramic radiography and cone beam CT: Analysis of tumors of the maxillary

Barros, Renata Quirino de Almeida 20 July 2011 (has links)
Made available in DSpace on 2015-09-25T12:18:24Z (GMT). No. of bitstreams: 1 Renata Quirino de Almeida Barros.pdf: 651574 bytes, checksum: 691f9ca6ac269e365c41d390ddf57550 (MD5) Previous issue date: 2011-07-20 / The diagnosis through image of neoplastic lesions that affect the maxillomandibular complex has been worthful for dentists in the elaboration of the surgical planning. This work aims to evaluate and correlationate the accuracy of panoramic radiography compared to the cone beam computed tomography, regarding the delineation of odontogenic and non-odontogenic tumors, diagnosed at the city of Campina Grande, Paraíba, Brazil, in the period between November 2009 and March 2011. There were 23 tumors diagnosed in various regions of the maxillomandibular complex, whose panoramic radiographies and computed tomographies were analyzed by 2 radiologists, in terms of the following radiographic aspects: radiolucency, presence or absence of mineralizations, definition of the lesions edges, expansion and breaking of bone cortical, as well as the relation to the anatomic structures and dental elements. The results were: 73,9% of patients with odontogenic tumors and 26,1% non-odontogenic, having histopathological standard for diagnosis, 65,2% of female patients and 34,8% of male patients, 56,5% of tumors located at the mandible, 34,8% at the maxilla and 8,7% at both arcs. It was observed the limitation of panoramic radiography in the analysis of the radiographic aspects. The cone beam tomography offered results more focused and statistically meaningful for the evaluation of bone destruction, as well as for the expansion of vestibular and palatine/lingual cortical. It was concluded that despite of panoramic radiography being the chosen examination to visualize lesions in maxilla, cone beam computed tomography provides better accuracy in terms of delineation, expansion and breaking of cortical bones, helping in the surgical planning and patient s follow up. / O diagnóstico por imagem das lesões tumorais que acometem o complexo maxilo-mandibular tem sido de grande valia para o cirurgião-dentista na elaboração de um planejamento cirúrgico. Este trabalho teve como objetivo avaliar e correlacionar a acurácia da radiografia panorâmica frente à tomografia computadorizada cone beam no delineamento dos tumores odontogênicos e não odontogênicos dos maxilares, diagnosticados no município de Campina Grande PB, no período de novembro de 2009 a março de 2011. Foram diagnosticados 23 tumores em várias regiões do complexo maxilo-mandibular, cujas radiografias panorâmicas e tomografias computadorizadas foram analisadas por 2 radiologistas, quanto aos seguintes aspectos imaginológicos: forma de radioluscência, presença ou não de mineralizações, definição das margens da lesão, expansão e rompimento de cortical óssea, bem como relação com estruturas anatômicas e dentes. Os resultados nos mostraram que 65,2% dos pacientes eram do sexo feminino e 34,8% do masculino, 56,5% dos tumores estavam localizados na mandíbula, 34,8% na maxila e 8,7% em ambos os arcos, 73,9% dos pacientes apresentaram tumores odontogênicos e 26,1% não odontogênicos, tendo como padrão de diagnóstico o histopatológico. Observou-se a limitação da radiografia panorâmica na análise dos aspectos radiográficos observados. A tomografia cone beam ofereceu resultados mais direcionados e estatisticamente significativos para avaliação do rompimento das corticais vestibular e palatina/lingual, bem como para a expansão óssea. Concluiu-se que apesar da radiografia panorâmica ser o exame de escolha para visualizar as lesões que acometem os maxilares, a tomografia computadorizada de feixe cônico proporcionou uma melhor acurácia no delineamento, expansão e rompimento das corticais ósseas, auxiliando no planejamento cirúrgico e na proservação do paciente.

Page generated in 0.0582 seconds