• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 480
  • 38
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 534
  • 326
  • 112
  • 97
  • 86
  • 78
  • 68
  • 55
  • 55
  • 51
  • 44
  • 38
  • 38
  • 36
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Métodos espectrofotométrico, RP-UPLC e microbiológico para determinação de linezolida em formas farmacêuticas / Spectrophotometric, RP-UPLC and microbiological methods for determination of linezolida in pharmaceutical preparations

Alessandro Morais Saviano 23 October 2015 (has links)
A linezolida é um antibiótico oxazolidinona efetivo contra bactérias patogênicas gram-positivas, incluindo Staphylococcus aureus resistente a meticilina (MRSA), Staphylococcus aureus resistente a glicopeptídeos (GISA) e enterococci resistente a vancomicina (VRE). As oxazolidinonas inibem a translação bacteriana na fase de iniciação da síntese de proteínas, enquanto que a síntese de RNA e DNA não são afetadas. Diversos métodos por cromatografia líquida de alta-eficiência (HPLC) têm sido relatados para a determinação da concentração de linezolida em plasma humano, soro e urina. Entretanto, um número pequeno de métodos estão disponíveis para a determinação de linezolida em formulações farmacêuticas. O objetivo deste trabalho foi desenvolver e validar métodos espectrofotométrico, de cromatografia líquida de ultraeficiência em fase reversa (RP-UPLC), doseamento microbiológico em placas e doseamento microbiológico rápido em microplacas com leitura cinética para a determinação de linezolida em soluções injetáveis e comprimidos. Adicionalmente, foram identificadas e quantificadas as principais fontes de incerteza relacionadas aos métodos. O desenvolvimento dos métodos utilizou uma abordagem racional, empregando-se planejamento de experimentos (análise fatorial e metodologia de superfície resposta) para otimização das condições analíticas. As fontes de incertezas foram identificadas empregando-se diagrama de Ishikawa e quantificadas conforme procedimento da Eurachem/Citac. Os métodos desenvolvidos apresentaram especificidade/seletividade, linearidade, precisão, exatidão e robustez adequadas, conforme os critérios estabelecidos pelo ICH e ANVISA. A análise estatística demonstrou equivalência entre os resultados providos por cada um dos métodos, sendo intercambiáveis entre si. Portanto, os métodos podem ser empregados no controle de qualidade de rotina na indústria farmacêutica. / Linezolid is an oxazolidinone antibiotic effective against gram-positive pathogenic bacteria, including methicillin-resistant Staphylococcus aureus (MRSA), glycopeptide-intermediate Staphylococcus aureus (GISA) and vancomycin-resistant enterococci (VRE). Oxazolidinones inhibit bacterial translation at the initiation phase of protein synthesis, while RNA and DNA synthesis are not affected. Several high performance liquid chromatographic (HPLC) methods have been reported to determine the concentration of linezolid in human plasma, serum and urine. However, a few number of methods are available to determine the concentration of linezolid in pharmaceutical dosage forms. The aim of the present work was to develop and validate a spectrophotometric method, a reverse-phase ultra-high performance liquid chromatographic method, microbiological assay and microbiological rapid assay in microplates using kinetic reading for the determination of linezolid in injections and tablets dosage forms. In addition, the most important sources of uncertainty were identified and quantified for each method. A rational approach was used in the development of these methods, using design of experiments (factorial design and response surface methodology) for optimization of analytical conditions. The sources of uncertainties were identified using Ishikawa diagram and quantified as described in Eurachem/Citac procedure. The developed methods were specific/selective, linear, precise, accurate and robust, as required by ICH and ANVISA guidelines. Statistical analysis showed equivalence among the results provided by each method, being interchangeable. Thus, the methods may be employed in routine quality control analysis by pharmaceutical industry.
432

Quantificação da incerteza volumétrica na modelagem geológica / Quantifying geological modelling uncertainty

Thyago de Oliveira da Silva 17 October 2016 (has links)
Gerenciar riscos é fundamental para que investimentos estejam protegidos de quaisquer fatores que possam modificar um cenário idealizado. Imprevistos não podem ser controlados, mas seus impactos podem ser minimizados se forem tomadas medidas de planejamento considerando diversos cenários da realidade. A indústria mineral se encaixa neste paradigma, pois diversas de suas áreas são estocásticas, desde flutuações econômicas e políticas até fenômenos relativos ao clima e à geologia. Uma destas características de difícil previsão é o volume das mineralizações em um depósito. Um cenário ideal é aquele em que é conhecido o valor esperado da variável de interesse, bem como sua dispersão, com mínimo e máximo definidos. Isto pode ser obtido a partir da combinação dos resultados de estimativa, que resultam em um valor esperado, aliados ao resultado das simulações, em que pode ser obtida a variância entre todos os cenários equiprováveis. Este trabalho propõe uma técnica para quantificar a incerteza dos volumes na modelagem geológica de domínios mineralizados em dois modelos geológicos, interpolado e interpretado, através da transferência da variância obtida nos resultados da simulação, e desta forma criar uma ferramenta de gerenciamento de risco e planejamento a partir dos resultados de incerteza. Para isto foram utilizados os dados de descrição geológica de 168 testemunhos de sondagem de um depósito de cobre, localizado no norte da Bahia. Os resultados mostraram a possibilidade em se utilizar os dados de variância da simulação para quantificar a incerteza em cada domínio do depósito. A partir do volume esperado em determinado modelo, e com os valores da variância da simulação, foi possível identificar uma gama de possibilidades volumétricas. Adicionalmente, a probabilidade de que cada bloco faça parte de um domínio foi calculada, e os volumes dos domínios foram parametrizados para auxiliar na avaliação da incerteza. / Managing risks is essential for investments being safe from any factors that may modify an idealized scenario. Unpredictabilities cannot be controlled, but their impacts can be minimized if planning measures are taken considering various scenarios of reality. The mining industry fits this paradigm, since several of its fields are stochastic, from economic and political fluctuations to phenomena related to climate and geology. One of these characteristics, which are difficult to predict, is the volume of mineralization at the deposit. An ideal scenario is the one in which both the expected value and its dispersion are known, with defined minimum and maximum. This can be achieved with the combination of results from estimates and simulations, the first providing the expected value and the last providing the variance of the variable. This research proposes a technique to quantify the volumetric uncertainty in geological modeling of mineralized domains on two geological models, interpreted and interpolated, by transferring the variance obtained in the simulation results, thus creating a risk and planning management tool from the uncertainty results. For that, we used a geological logging from a database set with 168 drillholes of a copper deposit located north of Bahia state, Brazil. The results showed that it is possible to use the variance from simulation to quantify the uncertainty in each deposit domain. Using the expected volume value in a specific model with the variance values of the simulations, it were able to identify a range of possibilities for the volumetric content of each domain. In addition, the probability of each block being a domain was calculated, resulting in a volume parametrization by probability that can assist in the uncertainty analysis.
433

Integração vertical em cadeias de suprimentos e os pressupostos da teoria dos custos de transação: um teste empírico

Silva, Adilson Aderito da 03 March 2009 (has links)
Made available in DSpace on 2016-03-15T19:31:18Z (GMT). No. of bitstreams: 1 Adilson Aderito da Silva.pdf: 1146737 bytes, checksum: 8cd5e83fb0f914d05834ba4cd0ffbb5b (MD5) Previous issue date: 2009-03-03 / Fundo Mackenzie de Pesquisa / Based on the transaction cost reasoning this doctoral dissertation proposed a model that theorizes on the relationship between uncertainty, bounded rationality, asset specificity, opportunism and vertical integration in supply chains. An extensive literature review was conducted in three basic fields: transaction cost economics; organizational theory; and strategy to better understand the definition of those variables and their theoretical relationship. The review also helped to identify scales used in previous research to measure the research variables. The identified scales were then back translated and adapted to be used in this research. The research instrument was pre-tested and then it was made available on the internet from April to October 2008 and managers from industrial organizations classified in the D section in the Brazilian SIC and also listed in the database of FIESP (São Paulo State Industry Association) were asked to participate in the survey. The section D includes industries that perform physical, chemical and biological transformation of inputs into new products. From the population we selected only firms classified by the association as medium or large sizes which resulted in a target of three thousand potential subjects. Electronic messages which explained the survey proposal and instructions to fill in the questionnaire were sent through the internet. All those that not answered the first message received another message few days later and they were again contacted by phone. Due to the nature of the study only middle managers and directors working in the target firms were asked to answer the questionnaire. Some 111 good responses were available in the end of data collection process and they represent 87 different firms and 14 economic activities the collected data were analyzed using the EQS 6.1 software, which allowed the validation of the research constructs through SEM. The use of this methodology represented an innovation in the research field, because it gives the possibility to include more variables in the basic model, and they are simultaneously considered in the search of explanations for vertical integration. This choice brought important methodological contributions to the research field. Validation of the uncertainty construct as multidimensional derived from three types of uncertainty. The second contribution was to test the construct bounded rationality as a second order latent variable and in the first order were used two types of uncertainty effect and response. The third contribution refers to the level of refinement introduced by the use of the EQS software and structural equation modeling. This approach allowed us to verify the validation of the theoretical model. The statistical significance of most tested direct and indirect relationships among constructs confirmed the proposed theoretical model. Another finding derived from the data is that the explanation of degree of vertical integration in supply chain has to consider all research constructs included in the model to interact together. So no single construct in the TCT can explain alone the vertical integration. / Neste trabalho um modelo teórico para testar o relacionamento entre incerteza, racionalidade limitada, especificidade dos ativos, o comportamento oportunista e o grau de integração vertical em cadeias de suprimentos foi proposto e testado. Para tal foi realizada uma revisão na literatura de Teorias das Organizações, Teoria dos Custos de Transação e Economia visando fundamentar os conceitos subjacentes nessas variáveis latentes e identificar escalas com indicadores que se apresentaram confiáveis em estudos prévios. A partir dessa revisão, elaborou-se um instrumento para a coleta de dados que ficou disponível on-line entre os meses de abril a outubro de 2008. O universo da pesquisa foi definido pelo conjunto de empresas da indústria de transformação classificadas na seção D do CNAE (2004) constantes na base da Federação das Indústrias do Estado de São Paulo - FIESP envolvendo a transformação física, química ou biológica de materiais, substâncias ou componentes para a obtenção de novos produtos. Nesse universo foram selecionadas e convidadas para participar da pesquisa 3000 empresas. O convite foi efetuado, num primeiro momento, a partir do envio de mensagens eletrônicas contendo os objetivos, as instruções e o link de acesso à pesquisa e, num segundo momento, o convite foi ratificado junto aos respondentes por meio de contatos telefônicos. Dada a sua natureza, a pesquisa de campo foi limitada àqueles que desempenhavam funções de Gerentes ou de Diretores em suas empresas, resultando numa amostra com 111 respondentes, que representaram 87 empresas em 14 setores de atividades econômicas. Os dados coletados foram processados com o software EQS 6.1 que permitiu operacionalizar e validar os construtos propostos por meio da Modelagem por Equações Estruturais. A utilização dessa metodologia de análise representou um avanço em relação aos estudos anteriores, pois possibilitou a inclusão de um número maior de variáveis latentes no modelo de mensuração para avaliar o grau de integração vertical em cadeias de suprimentos. Nesse sentido o estudo trouxe contribuições metodológicas importantes no campo da pesquisa empírica em Teorias das Organizações e Teoria dos Custos de Transação. A primeira foi a validação do construto de incerteza como um construto multidimensional que subsiste em incerteza de estado, de efeito e de resposta. A segunda foi operacionalização do pressupostode racionalidade limitada como um construto de segunda ordem a partir das incertezas de efeito e de resposta. A terceira contribuição está relacionada ao nível de refinamento introduzido pelo processamento dos dados com o EQS 6.1 por meio de Equações Estruturais. A partir dessa abordagem foi possível verificar que a validação do modelo proposto, foi suportada pelos dados empíricos. As significâncias estatísticas dos efeitos diretos e indiretos entre os construtos propostos confirmaram empiricamente o relacionamento entre: incerteza, racionalidade limitada; especificidade dos ativos; e, comportamento oportunista. Estes conceitos, que são apresentados como pressupostos e dimensões básicas na Teoria dos Custos de Transação, são relevantes para explicar o grau de integração vertical em cadeias de suprimentos somente se considerados conjuntamente.
434

CARACTERIZAÇÃO METROLÓGICA DE UM MEDIDOR VOLUMÉTRICO PARA PEQUENAS TAXAS DE FLUXO DE GÁS UTILIZANDO O MÉTODO DE DIFERENÇA DE PRESSÃO / CHARACTERIZATION OF A GAUGE METROLOGICAL VOLUMETRIC FOR SMALL FLOW RATE OF GAS USING THE METHOD PRESSURE DIFFERENCE

Abreu, Pedro Augusto Lopes 16 March 2011 (has links)
Made available in DSpace on 2016-08-17T14:53:15Z (GMT). No. of bitstreams: 1 Pedro Augusto Lopes Abreu.pdf: 1389353 bytes, checksum: 81ce9ae4d3b6d093a60100d28069418b (MD5) Previous issue date: 2011-03-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A system for measuring low rates of gas flow has great importance for some industrial and especially for scientific applications where usually high accuracy and low uncertainty are required. This type of measurement systems have undergone a great development in recent years primarily due to the concern with the release of gases in natural processes occurring in the environment, such as anaerobic biodegradation process which releases methane and the use in the production of biogas. In this work, the development of low-volume gas flow rate measurement system using the method of pressure difference in a container of known volume is presented. A microcontroller is used to control two valves located one gas inlet and the other at the gas outlet of the container. Appropriate analysis of uncertainty propagation is carried out, and components suitable are selected for the development of the meter in order to perform the measurement with low uncertainty. Simulations and experimental tests are presented for validating the proposed system. / Os sistemas de medição de pequenas taxas de fluxo de gás tem grande relevância nos âmbitos industriais e científicos, nos quais suas aplicações exigem geralmente medições com baixa incerteza. Esses sistemas de medição tem tido uma grande evolução ultimamente. Isso se deve, principalmente, à preocupação com a liberação de gases em processos biológicos naturais como, por exemplo, o gás metano liberado no processo de biodegradação anaeróbio, e que também é aproveitado como biogás. Neste trabalho, apresenta-se o desenvolvimento de um medidor para pequenos volumes de gases utilizando o método de diferença de pressão em um recipiente de volume conhecido. Um microcontrolador é utilizado no controle das duas válvulas localizadas na entrada e na saída do recipiente. São realizados estudos apropriados de análise e propagação de incertezas, e são escolhidos componentes adequados para o desenvolvimento e construção do medidor, de modo a realizar a medição com boa exatidão e baixa incerteza. Simulações e testes experimentais são apresentados para validação do sistema proposto.
435

Implementação de método de potência sonora em serra-mármore / Implementing a sound power method for testing noise on masonry saw

Barbosa, Adriano Aurelio Ribeiro, 1977- 25 August 2018 (has links)
Orientador: Stelamaris Rolla Bertoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-25T10:59:34Z (GMT). No. of bitstreams: 1 Barbosa_AdrianoAurelioRibeiro_D.pdf: 5486627 bytes, checksum: fd9ac7f13185126d6aabd57ae00f989b (MD5) Previous issue date: 2014 / Resumo: A poluição sonora e sua influência sobre o meio ambiente e a qualidade de vida das pessoas têm sido focos de várias pesquisas em diversas partes do mundo. Estudos apontam a construção civil como fator gerador de ruídos que incomodam a sociedade. A contribuição das máquinas e das ferramentas utilizadas nas obras tem influência direta neste processo. Os usos frequentes destes facilitadores estão entre as vertentes de melhoria de qualidade, racionalização dos processos e aplicação de inovações tecnológicas no setor. O estudo do comportamento e a caracterização dos ruídos ambientais nos canteiros de obras da construção civil, devido às operações com equipamentos elétricos, apresentam importância para o setor. A determinação do ruído gerado por máquinas, quando em contato com as superfícies de corte dos materiais de construção, contribui com as ações de controle do ruído em atividades desta natureza para fins ocupacionais e de conforto ambiental. A serra-mármore é uma máquina elétrica manual, portátil, largamente utilizada, na construção civil, para executar pequenos cortes e acabamentos em pisos, azulejos, telhas, tijolos e madeiras e destaca-se pela sua versatilidade, praticidade, leveza e ergonomia. O objetivo deste trabalho é propor um material de condição de carga padrão para implementação de método de determinação de potência sonora do ruído gerado por serra-mármore e estabelecer a incerteza de medição associada às operações. A metodologia utilizada para o estudo considerou os níveis de ruído gerados nas operações de corte em relação ao ruído do equipamento sem carga em concordância com a ISO 3744:2010, que especifica a determinação de níveis de potência sonora de ruído transmitido através do ar, por um método de engenharia, num campo livre sobre um plano refletor. Os resultados indicaram elevados níveis de ruído com a carga padrão proposta e diferentes materiais de construção em relação às atividades da serra-mármore sem carga. Os níveis globais de potência sonora obtidos nas operações chegaram a 110,1dB. A relação da condição do equipamento vazio e com carga apontam diferenças de até 10,0dB. Os resultados revelaram similaridade nas incertezas de medição nas operações de serra em diferentes condições de carga. Foi possível avaliar quantitativamente o nível de ruído gerado nas operações de corte, bem como propor um material de carga padrão para a determinação de níveis de potência sonora. Resultou em 4,3dB a incerteza de medição expandida nas operações da serra-mármore em campo aberto sobre um plano refletor. O estudo representa ainda uma contribuição na análise de ruído nas obras, considerando as dificuldades na obtenção de valores dos espectros sonoros nas operações de máquinas portáteis de construção civil na literatura, como a serra-mármore / Abstract: Worldwide, noise pollution and its influence on environment and quality of life have been studied. And so, such researches have pointed out the building construction as the main responsible for disturbing sounds today. In this sector, machinery and tools have direct influence on this process. Thus, the regular use of such tools are the main concern aiming quality improvement, streamlining processes and application of technological innovations in the industry. For this reason, the study and characterization of environmental noise behavior at construction sites (due to electrical equipment) is relevant for the sector, in order to contribute to noise control actions in construction activities aiming occupational purposes and environmental comfort. The masonry saw (circular saw for granite stone) is an electrical device, regularly used on building construction for cutting and shaping floors, tiles, bricks and woods and stands out for its versatility, practicality, lightness and ergonomics. Thus, the aim of our study is to design material of proper standard condition and measurement uncertainty associated with operations and measurements to implement the method for determining sound power of noise generated by masonry saw. The method applied in this study was comparing noise levels - generated by cutting operations - and the noise of the equipment without charge, according the ISO 3744:2010 (which specifies sound levels transmitted through the air, by a method of engineering, in a free field over a reflecting plane. Results have indicated high levels of noise with the proposed standard charge and different building materials in relation to the activities of the unloaded masonry saw. The overall sound power levels obtained from operations reached 110.1 dB. The ratio of unloaded and loaded device points to differences of up to 10.0 dB. Also, results have revealed a similarity in the measurement uncertainties in masonry saw operations on different load conditions. It was possible to quantitatively assess the noise level generated during cutting operations, so proposing a standard charge for determining sound power levels. Finally, the expanded measurement uncertainty has resulted in 4.3 dB of the masonry saw in an open field over a reflecting plane. Moreover, the study represents a great contribution for analyzing noise levels from the use of portable machinery on building construction, considering the difficulties in obtaining values of sound spectra in the literature / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil
436

Relações entre capital humano, sistemas de previdência e aposentadoria

Untem, Andre Okamoto 25 June 2012 (has links)
Submitted by Andre Untem (andre.untem@gmail.com) on 2012-12-19T16:03:46Z No. of bitstreams: 1 AndreOkamotoUntem_VersaoFinal.pdf: 2195184 bytes, checksum: 69027860a1e2b638618a529983245436 (MD5) / Approved for entry into archive by Marcia Bacha (marcia.bacha@fgv.br) on 2012-12-20T16:09:39Z (GMT) No. of bitstreams: 1 AndreOkamotoUntem_VersaoFinal.pdf: 2195184 bytes, checksum: 69027860a1e2b638618a529983245436 (MD5) / Made available in DSpace on 2012-12-20T16:10:00Z (GMT). No. of bitstreams: 1 AndreOkamotoUntem_VersaoFinal.pdf: 2195184 bytes, checksum: 69027860a1e2b638618a529983245436 (MD5) Previous issue date: 2012-06-25 / In this work, we will present a series of general and partial equilibrium models that deals with human capital accummulation, social security systems, labor supply and retirement. We willanalyse the relations between different mechanisms of human capital accummulation and productivity; relations between uncertaints and hypothesis about credit markets; and the influence of those variables on households' decision of retirment. / Neste trabalho, serão apresentados artigos que abordam modelos de equilíbrio geral e parcial que tratem da acumulação de capital humano, sistemas de previdência, oferta de trabalho e aposentadoria. São feitas análises entre diferentes mecanismos de acumulação humano e sua relação com produtividade; relações entre incertezas e hipóteses sobre mercados de crédito; e.a in uência dessas variáveis na aposentadoria das pessoas.
437

[en] DEVELOPMENT OF METHODOLOGY FOR CALIBRATING PIEZOELECTRIC TRANSDUCERS USED IN INTERNAL BALLISTICS FOR TRANSIENT PRESSURE MEASUREMENTS / [pt] DESENVOLVIMENTO DE METODOLOGIA DE CALIBRAÇÃO DE TRANSDUTOR PIEZELÉTRICO DE PRESSÃO UTILIZADO EM BALÍSTICA INTERNA

ALFREDO JORGE BAHIA HEINE 30 December 2004 (has links)
[pt] A presente pesquisa de mestrado, de interesse da indústria de armamento, mais especificamente no controle de qualidade de lotes de munição, relaciona-se com o desenvolvimento de metodologia para calibração de transdutor piezelétrico para medição de pressão transiente cuja duração é da ordem de milisegundos. Como sua principal contribuição, o trabalho disponibiliza metodologia própria de calibração ainda não disponível no País, atribuindo confiabilidade a medições realizadas em fenômenos associados ao que se denomina balística interna, que se constitui no estudo científico dos processos que ocorrem no interior de uma arma de fogo a partir do instante de iniciação (ignição) do propelente. Não obstante a faixa de pressão estudada, de 34,7 a 349,8 bar), ser baixa se comparada com as pressões desenvolvidas na balística interna, que podem até superar 6000 bar, a simples substituição do gerador de pressão por outro de maior capacidade é suficiente para a calibração numa faixa mais larga utilizando-se a mesma metodologia. O complexo processo de balística interna foi simulado em condições laboratoriais pela submissão brusca do sensor piezelétrico, objeto da calibração, originalmente montado em uma câmara diminuta (cerca de dez vezes menor que o volume total de fluido pressurizado) de óleo à pressão atmosférica, a um pico de pressão induzido pela comunicação da câmara a uma linha de óleo pressurizada à pressão de calibração pré-determinada através de uma bomba hidráulica, pressão esta que caracteriza um ponto de calibração. Complementando o aparatus experimental utilizado para simular o fenômeno da balística interna, foi utilizado um sistema de medição com tempo de resposta compatível (rise time < 5 us) à ordem de grandeza da duração do fenômeno estudado. O aparatus experimental utilizado é tal que permite alterar a duração desses eventos por meio de uma válvula de restrição, o que resultou em eventos com duração de 2 a 2200 ms. O monitoramento do sinal de resposta do transdutor piezelétrico no curso da calibração realizada permite estabelecer o tempo-limite associado ao qual o sinal mantém-se isento de indesejável atenuação, considerada fonte de erro na medição de pressão. O processo de calibração desenvolveu-se para 10 pontos distintos, perfazendo um total de 340 experimentos (variando-se o transiente de pressão imposto ao transdutor), monitorando-se o sinal de resposta do transdutor contra o valor da pressão medida por um manômetro calibrado pelo laboratório de pressão da PUC-Rio, credenciado pelo INMETRO e, portanto, assegurando rastreabilidade das medições ao Sistema Internacional de Unidades. Alterações no aparatus experimental permitem que calibrações usualmente realizadas em regime de pressurização sejam também realizadas em regime de despressurização, viabilizando, dentre outras análises possíveis, o estudo de estabilidade e histerese do sinal do transdutor. O método experimental desenvolvido não apenas mostrou-se tecnicamente viável e adequado às condições laboratoriais da faixa de pressão na qual foi validado (34,7 a 349,8 bar), como também se mostrou viável economicamente. A incerteza associada a esse método, obviamente, é maior que aquela obtida com uma balança de peso morto, que se baseia num método primário. A incerteza associada ao método de calibração desenvolvido no presente trabalho de pesquisa pode ser diminuída se for usado um sistema de medição de tensão com melhor exatidão. / [en] The current research, of armaments industry s interest, more specifically in the quality control of ammunition lots, is related to the development of methodology for calibrating piezoelectric transducers for transient pressure measurements associated with events whose duration is of the order of milliseconds. As its main contribution, this work presents proper methodology, not available yet in the Country, to ensure reliability to measurements of pressure in internal ballistics, which is the scientific study of the operating processes within the gun from at the moment when the burning process of the propellant is initiated. In spite of the low transient pressure range studied, 34,7 to 349,8 bar, when compared with the pressures developed in internal ballistics, up to 6000 bar, the simple replacement of the pressure generator for another one of larger capacity is enough to allow for calibration in a wider pressure range using the same methodology. The complex process associated to internal ballistics was simulated in laboratorial conditions by the abrupt exposure of the piezoelectric sensor, object of the calibration, planned and originally mounted in a small oil chamber (about ten times smaller than the total volume of fluid pressurized) maintained at atmospheric pressure, to a pressure peak introduced by the communication of the small chamber to a line of oil pressurized at a desired calibration pressure level by means of a hydraulical pump used to feed the oil system. Each calibration pressure condition corresponds to what is called a calibration point. Complementing the experimental apparatus used to simulate the phenomenon of the internal ballistics, an adequate measurement system (rise time < 5 us, therefore adequate to the time duration of the studied phenomenon) was used. The experimental apparatus employed is such that the time duration of the events could be changed by means of a restriction valve, allowing events with duration from about 2 to 2200 ms. Within the calibration process, the monitoring of the piezoelectric transducer output signal allowed for establishing a specific time-limit to ensure that the signal remained exempt of undesirable attenuation, considered a source of error in the measurement of the transient pressure. The calibration process was developed for 10 distinct points, totalizing 340 experiments (varying the transient pressure to which the transducer is exposed), monitoring the output signal of the transducer against the value of the pressure measured with a manometer calibrated in the accredited pressure laboratory of PUC-Rio, traceable to the national standard maintained by the Brazilian National Metrology Laboratory (INMETRO) and, therefore, ensuring overall traceability of measurements to the International System of Units (SI). Modifications introduced in the experimental apparatus used allow that calibrations usually carried out under a regime of pressurization may also be carried out under a regime of unpressurization, making possible other studies such as stability and hysteresis of the transducer s output signal. From the technical point of view the experimental method proved to be feasible and suitable to the laboratorial conditions for the pressure range to which it was validated (34,7 to 349,8 bar). It also revealed economically viable. Although validated, the uncertainty associated with the proposed method, obviously is greater than the uncertainty associated with a dead weight tester, which is based on a primary method. However, the uncertainty associated with the method of calibration herein proposed can be minimized whenever a more accurate voltage measurement system is used.
438

[en] METHODOLOGY FOR METROLOGICAL EVALUATION OF THE CHARACTERISTICS OF A PTC POLYMERIC RESETTABLE THERMISTOR / [pt] METODOLOGIA PARA AVALIAÇÃO METROLÓGICA DE CARACTERÍSTICAS DE UM TERMISTOR PTC POLIMÉRICO REGENERATIVO

REINALDO NIVALDO DA SILVA 22 September 2005 (has links)
[pt] Esta dissertação propõe uma metodologia para avaliação metrológica de características do termistor PTC polimérico regenerativo LP60-110 usado como protetor contra sobrecorrente e sobre temperatura. Expressa a determinação da incerteza de medição dos parâmetros temperatura, tensão, corrente elétrica e resistência ôhmica de amostras do dispositivo. O termistor PTC (Positive Temperature Coefficient) polimérico regenerativo surgiu na década de noventa, como um elemento de proteção muito importante em função de suas características especiais. Pode ser usado como protetor de sobrecorrente e sobre temperatura, partida de motores, compensação de temperatura e em circuitos em geral. Para realização da pesquisa foi montado um circuito constituído de um cronômetro, dois multímetros, uma fonte de alimentação estável, uma carga resistiva variável colocada em série com o dispositivo termistor PTC polimérico regenerativo LP60-110 e este foi colocado em uma estufa térmica a seco com um termopar tipo K, o que permitiu controlar sua temperatura. Este circuito possibilitou estabelecer de forma simples uma corrente de limiar do termistor PTC circulando pela malha, tornando este sensível apenas à variação da temperatura. Os dados registrados foram suficientes para construção de curvas características e análise para determinação da Incerteza de medição. Devido ao fato de não existirem muitas informações sobre o sensor no mercado, a contribuição principal deste trabalho é a sistematização do levantamento das características do termistor para a verificação da confiabilidade dos dados do fabricante, juntamente com sua incerteza, fornecendo ao mesmo tempo informações ainda não disponíveis ao projetista de sistemas de proteção. / [en] This research aims at the development of a methodology for experimentally characterizing a PTC polymeric resettable thermistor LP60-110, used as an overcurrent and over temperature protection device. Uncertainty of measurement of the parameters, such as temperature, voltage, current and ohmic resistance is also determined. The PTC (Positive Temperature Coefficient) polymeric resettable thermistor started to be used in the 90`s, as a very important protection device because of its special characteristics. It can be used as an over current and over temperature protection device in electronic circuits, for engine start-up and as a temperature compensation device. An electric circuit was built to measure the thermistor characteristics, consisting of an stable voltage source and a variable resistance in series with the thermistor, which was place in a dry oven. A K type thermocouple was attached to it, so that its temperature could be measured and controlled. A chronometer and two multimeters were used as measuring instruments. By gradually decreasing the circulating current through the circuit, the Joule effect could be neglected, and the thermistor resitance was made only a function of ambient temperature, which is easier to measured. The acquired data were used to build several characteristics curves, which were analyzed and compared to the available ones from the manufacturers. Due to the fact that there are not many available information about the sensor in the market, the main contribution of this work is the development of a systematic procedure to obtain the thermistor performance data, so that the manufacturer data can be verified, together with its uncertainty, providing at the same time information not presently available in the market for system designers.
439

[en] DESIGN OF EXPERIMENTS TO ANALYZE THE INFLUENCE OF WATER ON THE UNCERTAINTY OF OIL FLOW MEASUREMENT WITH ULTRASONIC METERS / [pt] PLANEJAMENTO DE EXPERIMENTOS PARA ANÁLISE DA INFLUÊNCIA DO TEOR DE ÁGUA NA INCERTEZA DE MEDIÇÃO DE VAZÃO DE ÓLEO COM MEDIDORES ULTRASSÔNICOS

FILIPE CARELI DE ALMEIDA 20 February 2018 (has links)
[pt] O objetivo desta dissertação é avaliar a influência do teor de água e do fator do medidor na incerteza de malhas fiscais de medição de óleo utilizando medidores ultrassônicos. A motivação deste trabalho advém do fato do Regulamento Técnico de Medição de Petróleo e Gás Natural (RTM) existente limitar quais metodologias podem ser utilizadas para realizar a análise de teor de água e qual a incerteza máxima permitida para a malha de medição na qual esta se insere, porém não define a incerteza desta, havendo o risco de se adotar um dos métodos de análise permitidos e, ainda assim, a incerteza de medição da malha ultrapassar a definida pela legislação. Além disso, o RTM adota um critério de repetibilidade para a validação das calibrações dos medidores ultrassônicos, portanto avalia-se também a influência deste na incerteza da malha. A metodologia utilizada foi o planejamento de experimentos, utilizando superfície de resposta. Os resultados demonstram que é possível simular a influência da incerteza da análise da água e do fator do medidor na incerteza da malha. Por fim, as conclusões demonstram que as médias atualmente encontradas para incerteza do teor de água são adequadas para manter a incerteza da malha dentro da permitida pelo RTM, porém com pouca variação pode-se exceder este limite; a influência da incerteza do fator do medidor foi inferior ou similar à do teor de água e, por fim, sugere-se a adoção de um critério limite de incerteza ao invés de um critério de repetibilidade para os medidores ultrassônicos. / [en] The aim of this dissertation is to evaluate the influence of water content dissolved in crude oil and the meter factor on the uncertainty of the fiscal oil metering using ultrasonic flow meters. The development of this work is motivated by the fact that the Technical Regulation for the Measurement of Oil and Natural Gas (RTM) limits which methodologies can be used for water analysis and what is the maximum permissible uncertainty for the oil flow meter in which it is inserted. However, the RTM doesn t define the uncertainty of the water analysis. There is a risk of adopting one of the permitted methods of analysis and, even so, the measurement uncertainty of the flow meter exceeds the defined by the legislation. In addition, the RTM adopts a repeatability standard when validating the calibration of ultrasonic meters, thus the influence of this on oil uncertainty is also evaluated. The methodology used is the design of experiments and response surface. The results demonstrate that the influence of the water content uncertainty analysis and of the meter factor on the uncertainty of the oil flow meter can be simulated. Finally, the conclusions show that the average currently found for uncertainty of water is adequate to maintain the oil uncertainty within the allowed by the RTM, but small variations may cause this limit to be exceeded. The influence of the meter factor uncertainty was inferior or similar to the water content and, finally, it is suggested the adoption of a standard limit of uncertainty instead of a standard of repeatability for the ultrasonic meters.
440

[en] REAL ESTATE PROJECT VALUATION UNDER UNCERTAINTY: A REAL OPTIONS APPROACH / [pt] AVALIAÇÃO DE PROJETOS DE INCORPORAÇÃO IMOBILIÁRIA SOB INCERTEZA: UMA ABORDAGEM POR OPÇÕES REAIS

FERNANDO SOUZA DE MOURA RIBEIRO 29 September 2004 (has links)
[pt] Determinar a viabilidade e a prioridade de investimentos potenciais é um passo crítico para a tomada de decisões no âmbito empresarial. O método mais difundido e aceito mundialmente para análise de projetos é o Fluxo de Caixa Descontado (FCD), onde o valor do projeto é determinado pelo Valor Presente Líquido (VPL). No entanto, o FCD não reflete o valor da ação gerencial, maximizadora de resultados, assumindo implicitamente que a firma detém passivamente seus ativos reais (projetos). Sendo este método, portanto, muito limitado para tratar de incertezas e flexibilidades e levando freqüentemente a decisões equivocadas. Considerado por muitos renomados autores um novo paradigma na avaliação de investimentos, a Teoria de Opções Reais (TOR) veio complementar a teoria do FCD, exercendo um papel de ponte entre a intuição estratégica e o rigor analítico. Este trabalho tem por objetivo não somente apresentar algumas das várias flexibilidades existentes em projetos de incorporação imobiliária, como também mostrar como calcular seu valor de forma simples, intuitiva e adequada aos principais problemas de investimento enfrentados por empresas incorporadoras no seu dia a dia. A abordagem de avaliação de investimentos utilizando a TOR possibilita o entendimento das flexibilidades e incertezas inerentes ao processo de incorporação, auxiliando na elaboração de contratos com terceiros e provendo preciosos insights sobre negócios e investimentos estratégicos cada vez mais importantes devido ao acelerado ritmo de mudança econômica. / [en] In an enterprise scope, one critical step in the decision making process is the determination of potential investments feasibility and priority. Worldwide the most accepted method for evaluating a project is the Discounted Cash Flow (DCF), where the value of the project is given by the Net Present Value (NPV). However, the DCF does not reflect the value of managerial action, which maximizes results, assuming implicitly that the firm manages its real assets (projects) passively. Therefore, this method is too limited to deal with uncertainties and flexibilities and often leads to wrong decisions. Considered by many respected authors as a new paradigm in investment valuation, the Real Options Theory is viewed as a complement to standard DCF analysis which bridges the gap between strategic intuition and analytical rigor. This work aims not only to introduce some of the many flexibilities that exist in real estate development projects, but also to show how to evaluate projects in a simple and intuitive manner suitable for the investment decisions that developers face day by day. The Real Options approach provides the understanding of the flexibilities and uncertainties inherent to the project development process, assisting in contract making with third parties, as well as providing precious insights about businesses and strategic investments, insights that are more important than ever given the rapid pace of economic change.

Page generated in 0.0384 seconds