• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • Tagged with
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sací měřič rezonance s větší měřicí cívkou / Grid dip meter with large-diameter measuring coil

Obr, Michal January 2011 (has links)
This master’s thesis deals with grid dip meter, its operating principle, characteristics and with measuring procedure. The thesis contains basic division of oscilators, its characteristics and operating principal. The master`s thesis contains complete design of grid dip meter with large-diameter measuring coil which is placed outside the device. Grip dip meter is made of SMD components on a one-sided printed wiring. Grip dip meter consist of transformer itself, that has two secondary windings as a supply for resonance meters and internal digital frequency meter. The device has analog panel gauge and BNC input for extrenal counter.
2

Utveckling av koncept för att reglera reaktiv effekt vid generatordrift via PLC : Framtagande och provning av prototyp / Development of concepts for regulating reactive power during generator operation via PLC : Creation and testing of prototype

Gran, Erik, Hård, Erik January 2019 (has links)
I projektet utreds möjligheterna kring att kunna kontrollera en generators reaktiva effektproduktion genom att styra magnetiseringsströmmen från en PLC. Som metod för styrning från PLC beslutades att en signal på 0-5V skulle användas. För att reglera magnetiseringen, och därmed i förlängningen den reaktiva effekten, beslutades att den befintliga manuella potentiometern skulle ersättas med två parallellkopplade digitala potentiometrar av typen MCP4261 som kontrollerades av en mikrokontroller. Att de digitala potentiometrarna skulle parallellkopplas beslutades efter en förstudie som visade på att det skulle resultera i en noggrannare reglering utan någon inskränkning på användbart reglerspann. Praktisk provning av mikrokontroller och digitala potentiometrar gav ett tillfredsställande och bra resultat med god upplösning. / This project investigates the possibilities of being able to control a generators reactive power production by controlling the excitation current from a PLC. As a method for controlling from PLC, it was decided that a signal of 0-5V should be used. In order to regulate the magnetization, and hence in the long term the reactive power, it was decided that the existing manual potentiometer would be replaced by two parallel-connected digital potentiometers of the type MCP4261 controlled by a microcontroller. The fact that the digital potentiometers would be connected in parallel was decided after a feasibility study which showed that in this way it would result in a more accurate regulation without any restriction on the usable control span. Practical testing of microcontrollers and digital potentiometers provided a satisfactory result with a good resolution.
3

Laut, Ton, Stärke

Schreiner, Florian 03 May 2010 (has links)
Historisch wird die Arbeit von zwei Daten her begrenzt, von den ersten hör-physiologischen Experimenten seit 1850, und von den massenwirksamen akustischen Inszenierungen der 1930er Jahre in „real auditory perspective“. Die Arbeit beginnt in Kapitel I mit dem tragischen Fall des Regisseurs und langjährigen Psychiatrie-Patienten Antonin Artaud, der die Sprache zugunsten von Lauten, Gebärden und Schreien verlässt. Seine Experimente zum Theater geben zu einer ersten Korrektur von Bildlichkeit Anlass. In Kapitel II wird der Vorrang der Bildlichkeit grundsätzlich in Frage gestellt, die Differenz von Bild und Klang wissenschaftshistorisch auseinandergesetzt, und ein „acoustic turn“ zur Welt vorbereitet. Die Untersuchungen des Physiologen und Akustikers Hermann von Helmholtz sind hier maßgeblich, denn sie beeinflussen die Technische Akustik von ihren Anfängen her. Das Kapitel III schließlich untersucht im transatlantischen Vergleich die technischen Bedingungen nach 1900. Die Beschallungsanlage hat nun die Fähigkeit, alltäglich in den Dienst genommen zu werden, und auch politischen Manipulationen diensthaft zu sein. / Historically the work is framed by two dates, by the physiological experiments of hearing and the mise en scène of a massed and sonic attack in so called „real auditory perspective“ of the 1930s. The first chapter starts with the tragedic and long living psychiatric case Antonin Artaud, who moves away from clarity of sounds to phones, gestures and crying. Such experiments give cause for a fundamental rethinking of meaning in the sense of picture, and leads to the second chapter which argues in more detail for the lap of our sonic understanding of the world. This way speeds up to an „acoutic turn“ by a retour to the biological grounds of sonic perception. The physiological and acoustic inquiries of Hermann von Helmholtz fit here to the ground for him being starting point of what will later be called „technische Akustik“. The third chapter bridges Europe´s early Telefunken-years with the United States and their chief acousticians at the legendary Bell Laboratories, and seeks finally for light in scientific amnesia against progress and control, or what the germans call „Betriebsamkeit“ and „Gestell.“ (Heidegger)

Page generated in 0.0387 seconds