Spelling suggestions: "subject:"lowlevel"" "subject:"low.level""
241 |
Estudo dos efeitos do laser de baixa intensidade na angiogênese em ruptura parcial do tendão calcâneo de ratos. / Study of the low level laser effect on angiogenesis in partial rupture of achilles tendon (tendo calcaneus) in rats.Salate, Ana Claudia Bonome 20 December 2004 (has links)
Made available in DSpace on 2016-06-02T20:19:19Z (GMT). No. of bitstreams: 1
DissACBS.pdf: 10545595 bytes, checksum: 079933a164ff065ae11e54e43ae5200a (MD5)
Previous issue date: 2004-12-20 / The purpose of this study was to analyze the 660 nm GaAlAs laser effect with 10 mW and
40 mW, during 10 seconds, on angiogenesis process and repair quality after partial lesion of
Achilles tendon in rats. It was used 104 male rats, that 96 rats had been submitted to lesion
by a falling of 186 g from a height of 20 cm, above the right tendon. These rats had been
randomly divided in 3 groups, treated in 3 (n = 32), 5 (n = 32) and 7 (n = 32) days,
respectively. Each of these groups was divided again into 4 subgroups, which were
submitted to laser with mean output of 10 mW (n = 8) and 40 mW (n = 8), a sham
treatment (n = 8), and a group with no treatment (n = 8). The analyzes were made by
vessels count that have been previous prepared with nanquim ink and by a semiqualitative
analyze of polynuclear cells presence, mononuclear cells presence, collagen organization
and neovascularization. A fourth group with 8 animals was established as control, without
lesion and used as reference for qualitative analyze. The comparison of the groups made
evident that the animals submitted to laser showed more vessels number than the control
groups (p<0,05) and the 40 mW subgroup showed better vascularization than the others
after 3 days of irradiation. (p<0,01). The semiqualitative analyze showed statistical
difference (p<0,05) when considering collagen organization and neovascularization in the
comparison between the 10 mW, 40 mW and control. Qualitatively, the groups treated with
laser showed better repair aspect. The results permit us to conclude that Low Level Laser
Therapy with 660 nm promoted an increase of the blood vessels number and better repair
quality and the mean output of 40 mW had begun the neovascularization precocious,
showing significant difference after 3 days of application. / A proposta desse estudo foi analisar os efeitos do laser AsGaAl, de 660 nm, com 10 mW e
40 mW de potência de saída, aplicado durante 10 segundos, no processo de angiogênese e
qualidade de reparo após lesão parcial do tendão calcâneo de ratos. Foram utilizados 104
ratos machos, sendo que 96 foram submetidos à lesão com a queda de um peso de 186
gramas na altura de 20 cm sobre o tendão direito. Estes foram divididos aleatoriamente em
3 grupos, tratados em 3 (n = 32), 5 (n = 32) e 7 (n = 32) dias, respectivamente. Cada um
desses grupos foi ainda dividido em 4 subgrupos, submetidos ao laser com potência de
saída de 10 mW (n = 8) e 40 mW (n = 8), grupo placebo (n = 8) e grupo sem tratamento (n
= 8). As análises foram feitas através da contagem dos vasos que foram previamente
corados com tinta nanquim e por meio de uma análise semiqualitativa da presença de
células polimorfonucleares, mononucleares, organização de colágeno e neovascularização.
Um quarto grupo com 8 animais foi estabelecido como controle padrão, sem lesão que foi
utilizado como referência para a análise qualitativa. A comparação dos grupos evidenciou
que os animais irradiados mostraram maior número de vasos do que os grupos controle
(p<0,05) e o subgrupo de 40 mW apresentou melhor vascularização que os demais após 3
dias de irradiação (p<0,01). A análise semiqualitativa evidenciou diferença estatística
(p<0,05) quando foi considerada a organização de colágeno e a neovascularização na
comparação entre os grupos 10 mW e 40 mW com os controle. Qualitativamente os grupos
tratados com laser apresentaram melhor aspecto do reparo. Os resultados nos permitem
concluir que a terapia laser de baixa intensidade, com comprimento de onda de 660 nm
promoveu aumento na neovascularização e melhora na qualidade de reparo e a potência de
saída de 40 mW iniciou a neovascularização precocemente, mostrando diferença
significativa após 3 dias de aplicação.
|
242 |
Ensaio clínico randomizado sobre a efetividade do laser em baixa intensidade no alívio da dor perineal no parto normal com episiotomia / Randomized clinical trial on the effectiveness of low-level laser therapy in the relief of perineal pain after normal childbirth with episiotomyJaqueline de Oliveira Santos 22 December 2010 (has links)
Introdução: A dor perineal é um dos efeitos adversos mais comuns da episiotomia, constituindo uma das morbidades maternas mais frequentes. Considerada como um dos maiores avanços na área da saúde, a irradiação com laser em baixa intensidade vêm se mostrando bastante promissora no tratamento de doenças musculoesqueléticas, por sua ação analgésica, anti-inflamatória e pela aceleração do processo cicatricial. Objetivo: Avaliar a efetividade da aplicação do laser em baixa intensidade para alívio da dor na região perineal após a episiotomia. Método: Trata-se de um ensaio clínico controlado, randomizado, paralelo e com mascaramento da participante e da pesquisadora. A amostra constitui-se de 114 puérperas com parto normal com episiotomia médio-lateral direita internadas no Alojamento Conjunto do Amparo Maternal, que referiram dor perineal 3, pela escala numérica de 0 a 10. Foram divididas em três grupos de 38 mulheres: grupo experimental infravermelho - tratadas com laser 780 nm; grupo experimental vermelho - irradiadas com laser 660 nm e grupo controle - submetidas à simulação do tratamento, mas sem irradiação do feixe de luz. Foi utilizado um laser de diodo, tamanho do spot de 0,04 cm2, dose de 8,8 J/cm2, potência de 35 mW, duração da irradiação de 10 segundos por ponto, energia de 0,35 J por ponto e energia total de 1,05 J. O mesmo protocolo de irradiação foi aplicado nos grupos experimentais, infravermelho e vermelho. A aplicação foi realizada de modo pontual, diretamente sobre a episiotomia, irradiando-se a porção central e as extremidades, superior e inferior da lesão, perfazendo três pontos de irradiação. A intensidade da dor perineal foi avaliada antes, imediatamente e 30 minutos após a irradiação, pela escala numérica de 0 a 10. A coleta de dados foi realizada entre novembro de 2009 e março de 2010, após a aprovação do Comitê de Ética em Pesquisa com Seres Humanos. Resultados: A idade média das puérperas foi de 22,8 ± 4,4 anos, a maioria era primigesta (80,7%) e nulípara (88,6%). As médias da dor perineal intra-grupo antes e imediatamente após a irradiação apresentaram diferença estatisticamente significativa nos três grupos (p0,001). Também houve diferença significativa na comparação intra-grupo das médias da dor perineal imediatamente e 30 minutos após a intervenção (p0,05), e antes e 30 minutos depois da irradiação (p0,001) nos três grupos analisados. A comparação das médias da dor perineal entre os grupos controle, infravermelho e vermelho não demonstrou diferença significativa nos três momentos de avaliação, indicando que os resultados analgésicos obtidos nos grupos tratados com laser em baixa intensidade foram equivalentes aos do grupo controle. Não foi constatada diferença significativa na proporção de redução da dor perineal entre os três grupos de comparação, imediatamente e 30 minutos depois da intervenção (p=0,234), indicando que o alívio da dor foi similar entre os grupos. A maioria das púerperas submetidas à laserterapia (96,0%) teve opinião favorável à utilização do laser na prática clínica, considerou o procedimento confortável (93,4%) e mencionou que repetiria o tratamento em outro período pós-parto (96,5%). Conclusão: O protocolo de tratamento com laser em baixa intensidade utilizado não demonstrou benefícios no alívio da dor perineal comparando-se os grupos experimentais com o controle. É necessário que novas propostas de pesquisa, analisando diferentes protocolos terapêuticos com o laser em baixa intensidade, sejam desenvolvidas para determinar um protocolo ideal efetivo no alívio da dor e do desconforto perineal entre as puérperas. / Introduction: Perineal pain is one of the most common adverse effects of episiotomy, constituting one of the most common maternal morbidity. Regarded as one of the biggest advances in health care, the low-level laser therapy have been shown very promising for the treatment of musculoskeletal diseases, for its analgesic and anti-inflammatory effects and for accelerating the healing process. Objective: To evaluate the effectiveness of the application of low intensity laser for pain relief in the perineal region after normal childbirth with episiotomy. Method: This is a controlled clinical trial, randomized, parallel, with blinding of participant and researcher. The sample consisted of 114 women during puerperium after a normal birth with right mediolateral episiotomy staying in the Communal Recovery Area of the Amparo Maternal, who reported perineal pain 3 on a scale of 0 to 10. The women were divided into three groups of 38 women: infrared experimental group - treated with laser with 780 nm; red experimental group - irradiated with 660 nm laser and a control group - underwent treatment simulation, but without irradiation of light beam. It was used a diode laser, with spot size of 0.04 cm2, the dose of 8.8 J/cm2, 35 mW power, irradiation duration of 10 seconds per point, 0.35 J of energy per point and total energy of 1.05 J. The same irradiation protocol was applied in the experimental groups, infrared and red. The application was done in punctual mode, directly over the episiotomy, radiating from the central portion and edges, top and bottom of the trauma, making up three points of irradiation. The perineal pain intensity was evaluated before, immediately and 30 minutes after irradiation, on a numeric scale from 0 to 10. The data were collected between November 2009 and March 2010, after the approval by the Research Ethics Committee. Results: The average age of the mothers was 22.8 ± 4.4 years, the majority were primiparous (80.7%) and nulliparous (88.6%). The average intra-group perineal pain before and immediately after irradiation showed a statistically significant difference in the three groups (p0.001). There was also a significant difference intra-group averages of perineal pain immediately and 30 minutes after the intervention (p0.05), and 30 minutes before and after irradiation (p0.001) in the three groups analysed. The comparison of the average of the perineal pain between the control, infrared and red groups showed no significant difference in the three evaluation moments, indicating that the analgesic results obtained in groups treated with low-level laser therapy were equivalent to the control group. There was no significant difference in the proportion of relief of perineal pain among the three comparison groups, immediately and 30 minutes after intervention (p=0.234), indicating that relief pain was similar between groups. The majority of the women underwent low-level laser therapy (96.0%) had a favorable opinion on the use of lasers in clinical practice, found the procedure comfortable (93.4%) and reported that would repeat the treatment in another postpartum period (96.5%). Conclusion: The treatment protocol with low-level laser therapy used in this study showed no benefit in the relief of perineal pain in the comparison between experimental groups with control. It is necessary that new research proposals, analyzing different treatment protocols with the laser at low-level laser therapy, should be developed to determine an ideal protocol in relief of perineal pain among the mothers.
|
243 |
Efeitos da terapia laser de baixa intensidade na regeneração muscular de ratos após criolesãoRodrigues, Natalia Camargo 01 March 2013 (has links)
Made available in DSpace on 2016-06-02T19:02:41Z (GMT). No. of bitstreams: 1
5282.pdf: 2759184 bytes, checksum: ddd5666e5ff979383a7a5f6cdf80a469 (MD5)
Previous issue date: 2013-03-01 / Financiadora de Estudos e Projetos / Skeletal muscle injuries from sport activities are usual, but despite the inherent healing capacity of muscle tissue, this process can be impaired depending on the injury extension, what can lead to atrophy, fibroses, pain and functional recovery incomplete, increasing the risks of recurrent lesions. In addition, biophysical and biochemical resources have been studied in an attempt to enhance the muscle regeneration process, as the low level laser therapy (LLLT). Many studies have showed that this therapeutic modality stimulates positives responses during muscle healing process. Thus, two studies were performed with the aim of evaluating the effects of LLLT (InGaAlP 660 nm), with the fluences of 10 J/cm2 and 50 J/cm2, during Tibiales anterior muscle regeneration after cryolesion. Sixty three Wistar rats (3 month of age, ±300 g) were randomly divided into 3 groups: injured control group (CG) injured animals without any treatment; treated group, at 10 J/cm2 (G10) and treated group, at 50 J/cm2 (G50). Each group was divided into 3 different subgroups (n=7) and on days 7, 14 and 21 post-injury, were sacrificed. The laser irradiation was performed at a single point and started 48 hours after injury, 5 times per week (each 24 hours), followed by an interval of 48 hours. At the first study, the effects of LLLT were analyzed on the muscle regeneration related on molecular mechanisms involved at repair process. The results showed a downregulation of mRNA Cox-2 expression in all treated groups after 14 and 21 days. On day 7, both treated groups had a downregulation of mRNA Vegf expression, but had a increase after 14 and 21 days of treatment, meanly at 50 J/cm2. The mRNA MyoD expression was upregulated with the higher fluence, in all periods evaluated, and with the lower fluence the MyoD levels increased only after 21 days. The Myogenin expression was downregulated in both treated groups on day 7, and was upregulated with dose of 10 J/cm2 after 21 days. These responses suggest that LLLT can improve the skeletal muscle regeneration through the gene expression stimulation. At the second study, the effects of LLLT were evaluated during muscle regeneration, through histological and immunohistochemical aspects. The treated groups had an inflammatory process modulation after 7 days. On day 14, the treated animals, with both fluences, showed organized new muscle fibers and less granulation tissue. After 21 days of lesion, all groups had complete tissue repair. Moreover, the irradiated groups had less necrosis area at the first experimental period evaluated, and, also had more blood vases quantity after 14 and 21 days, at 50 J/cm2. The immunohistochemistry analysis showed Myogenin expression in all experimental groups after 7 and 14 days, and at day 21st; the immunoexpression was detectable in the control group and in the treated group with lower fluence. Superior MyoD expression appeared in both treated groups during all evaluated periods. Concluding, both fluencies of LLLT played positive effects on muscle repair. Such findings are fundamentals to elucidate the biological and molecular mechanisms involved in the skeletal muscle regeneration. / Lesões do sistema músculo esquelético decorrentes de atividades esportivas são comuns, porém apesar da capacidade regenerativa intrínseca do tecido muscular, este processo pode ser prejudicado de acordo com a extensão da lesão, causando atrofia, fibrose, dor e incompleta recuperação funcional, aumentando o risco de lesões recorrentes. Dentro desse contexto, recursos biofísicos e bioquímicos tem sido estudados na tentativa de acelerar o processo de regeneração muscular, como a terapia laser de baixa intensidade (LLLT). Vários estudo demonstram que esta modalidade terapêutica estimula respostas positivas durante o reparo do tecido muscular. Diante disso, foram desenvolvidos dois estudos com o objetivo de verificar os efeitos da LLLT (InGaAlP 660 nm), com as fluências de 10 J/cm2 e 50 J/cm2, durante a regeneração do músculo tibial anterior criolesionado. Sessenta e três ratos da linhagem Wistar (3 meses de idade, ±300 g) foram distribuídos randomicamente em 3 grupos: grupo controle lesado sem nenhum tratamento (GC), grupo lesado e tratado com 10 J/cm2 (G10) e grupo lesado e tratado com 50 J/cm2 (G50). Ainda, todos os grupos foram subdivididos em 3 subgrupos (n=7), onde os animais foram eutanasiados depois de 7, 14 e 21 dias da indução da lesão. A irradiação laser foi realizada em um único ponto e se iniciou 48 horas após a criolesão, 5 vezes por semana (a cada 24 horas), seguidos de um intervalo de 48 horas. No primeiro estudo, foram analisados os efeitos da LLLT na regeneração muscular em relação aos mecanismos moleculares envolvidos no processo de reparo. Os resultados demonstraram que ocorreu uma redução da expressão do RNAm do Cox-2 em todos os grupos irradiados após 14 e 21 dias. No sétimo dia, a expressão do RNAm do VEGF não aumentou nos dois grupos tratados, entretanto sua expressão aumentou depois de 14 e 21 dias de tratamento, principalmente com a fluência de 50 J/cm2. A expressão do RNAm da MyoD foi aumentada com a fluência maior, em todos os períodos analisados, e com a fluência menor apenas depois de 21 dias. A expressão da Miogenina foi reduzida em ambos os grupos tratados em 7 dias, e foram aumentadas com a fluência de 10 J/cm2 depois de 21 dias. Estes resultados sugerem que a LLLT pode melhorar a regeneração muscular através da estimulação da expressão gênica. No segundo estudo, foram avaliados os efeitos da LLLT durante a regeneração muscular, nos seus aspectos histológicos e imunohistoquímicos. Uma modulação do processo inflamatório em 7 dias foi visualizada nos grupos tratados. No 14o dia, os animais irradiados, com as duas fluências, apresentaram fibras musculares jovens organizadas e pouco tecido de granulação. Depois de 21 dias de lesão, todos os grupos apresentaram tecido muscular organizado similar ao músculo esquelético sem lesão. Além disso, uma menor área de necrose no primeiro período experimental foi observada nos grupo tratados e uma maior quantidade de vasos sanguíneos depois de 14 e 21 dias foi visualizada no grupo tratado com a fluência de 50 J/cm2. A imunohistoquímica demonstrou expressão da Miogenina em todos os grupos experimentais depois de 7 e 14 dias, e no 21o dia, no grupo controle e no grupo tratado com a menor fluência. Maior expressão da MyoD esteve presente nos grupos tratados em todos os períodos avaliados. Concluindo, as duas fluências da LLLT desempenharam efeitos positivos durante o reparo muscular. Tais resultados são fundamentais na elucidação dos mecanismos biológicos e moleculares envolvidos na regeneração muscular.
|
244 |
Variabilidade em escala associada com jatos de baixo nível e ondas de gravidade na camada limite noturna do Pantanal / Scale variability associated with low-level jets and gravity waves in the nocturnal boundary layer in PantanalMartins, Hardiney dos Santos 22 August 2011 (has links)
The Nocturnal Boundary Layer (NBL) turbulent structure above Pantanal Mato-Grossense, under
the influence of low-level jets (LLJ) and gravity waves (GW), is investigated. Experimental data
obtained during the Interdisciplinary Pantanal Experiment (IPE) dry season (IPE-2), and wet
season (IPE-3), carried out between 07th and 22th September, 1999, and 16th and 28th February,
2002, respectively, according to database from Universidade Federal do Mato Grosso, city of
Corumbá. Radiosonde data have been used to identify LLJ presence and classify them as: type 1
LLJ (jet associated to the sheltering surface) and type-2 LLJ (jet which causes upside-down
mixture). In addition to the radiosonde data, fast response data (wind velocity components,
temperature and humidity), measured from a 25m high micrometeorological tower, at 16Hz (IPE-
2) and 8Hz (IPE-3) samples were used. These fast response data were then decomposed in time
and scale via Wavelet Transform (WT), with complex Morlet mother wavelet. From the phase
difference between the wind velocity s vertical component (w) and temperature (T), obtained
through wavelet s cross spectrum, the presence of GW (phase difference near to 90º criterion)
were detected. The next step was to establish categories to analyse Pantanal NBL characteristic
state phenomena, which were based on LLJ, GW and length groups of occurrence. Such groups
are: type 1 LLJ, type 2 LLJ, no LLJ, with GW and no GW. From the amount of data of each
group, statistic parameters (variance, skewness, adimensional kurtosis, correlation coefficients
and covariances) were estimated by scale, in order to investigate the Pantanal NBL turbulence
structure and its variability in scale under the action of each of these groups. It was noticed that,
above all groups, type 1 LLJ is the most global intermittence provocative forcing in all micrometeorological series of data in Pantanal. On the other hand, type 2 LLJ is the less global
intermittence provocative forcing. With GW group shows an intermediate behavior between
groups type 1 LLJ and type 2 LLJ when considering global intermittence promotion. The length
scales 0.4m to 5000m were resolved in this study. It was also noticed that Pantanal NBL shows
two scale bands with remarkable different characteristics due to predominant distinct forcings in
it. For the first length scale band it prevails a mechanical force in the statistical parameters
behavior, to all groups and in both seasons. For the second length scale band it prevents the
action of buoyancy forces and mesoscale effects in the statistical parameters behavior in
Pantanal. As a result, it predominate stable conditions in the dry season; in the wet season,
however, NBL may present as a slightly unstable layer, due to a bigger water heat capacity and
its ability to behave as a energy sink during the day and heat source during the night. The early
evening transition period clearly shows a stable behavior to the dry season and unstable to the
wet season. / Investiga-se a estrutura da turbulência na Camada Limite Noturna (CLN) acima do Pantanal
Mato-Grossense sob a influência de jatos de baixo nível (JBN s) e ondas de gravidade (OG s). Os
dados experimentais são provenientes do Experimento Interdisciplinar do Pantanal (IPE), na
estação seca (IPE-2), realizado no período entre 07 e 22 de Setembro de 1999, e na estação
inundada (IPE-3), realizado no período entre 16 e 28 de Fevereiro de 2002, na base de estudos da
Universidade Federal do Mato Grosso do Sul, no município de Corumbá. Utilizaram-se dados de
radiossondagens para identificar a presença e classificar os JBN s como: JBN tipo 1 (jato
associado à blindagem da superfície) e JBN tipo 2 (jato que promove mistura de cima para
baixo). Além dos dados de radiossondagem, utilizaram-se dados de resposta rápida (componentes
da velocidade do vento, temperatura e umidade) medidos em torre micrometeorológica de 25m
de altura a uma taxa de amostragem de 16Hz (IPE-2) e 8Hz (IPE-3). Os dados de resposta rápida
foram decompostos em tempo e escala via Transformada em Ondeletas (TO), com ondeleta-mãe
complexa de Morlet. A partir da diferença de fase entre a componente vertical da velocidade do
vento (w) e temperatura (T), obtida através do espectro cruzado de ondeleta, detectou-se a
presença de OG s (critério de diferenças de fase próximas de 90º).A partir disso estabeleceram-se
categorias para análise de fenômenos característicos do estado da CLN pantaneira, as quais, se
basearam em classes de ocorrência de JBN, de OG e duração das mesmas. As classes são: com
JBN tipo 1, com JBN tipo 2, sem JBN, com OG e sem OG. A partir do conjunto de dados de cada
classe, foram estimados parâmetros estatísticos (variâncias, skewnesses, curtoses adimensionais,
coeficientes de correlação e covariâncias), por escala, para investigar a estrutura da turbulência na
CLN do Pantanal e sua variabilidade em escala sob a ação de cada uma dessas classes. Observouse
que o JBN tipo 1, entre todas as classes, é o forçante que mais promove intermitência global nas séries de dados micrometeorológicos do Pantanal. Por outro lado, a classe JBN tipo 2 é o
forçante que menos promove intermitência global. A classe com OG apresenta um
comportamento intermediário entre as classes JBN tipo 1 e JBN tipo 2 na promoção de
intermitência global. Foram resolvidas escalas de comprimento de 0,4m até 5000m. Observou-se,
também, que a CLN do Pantanal apresenta duas bandas de escalas com características
marcadamente diferentes devido aos forçantes distintos predominantes nas mesmas. Para a
primeira banda de escalas de comprimento predomina a ação mecânica no comportamento dos
parâmetros estatísticos, para todas as classes e nas duas estações. Para a segunda banda de escalas
de comprimento predomina a ação das forças de flutuabilidade e efeitos de mesoescala no
comportamento dos parâmetros estatísticos no Pantanal. Como consequência disto, na estação
seca predominam condições estáveis e na estação inundada, a CLN pode apresentar-se como uma
camada levemente instável, devido a maior capacidade térmica da água e de sua capacidade de
comportar-se como sumidouro de energia durante o dia e fonte de calor durante a noite. O
período de transição tarde-noite demonstra claramente um comportamento estável para a estação
seca e instável para a estação inundada.
|
245 |
Os efeitos do Biosilicato® e do laser terapêutico de baixa potência no processo de consolidação em tíbias de ratos / The effects of biosilicate® and low level laser therapy on bone consolodation in ratsT, Poliani de Oliveira 21 December 2009 (has links)
Made available in DSpace on 2016-08-17T18:39:32Z (GMT). No. of bitstreams: 1
2923.pdf: 9264279 bytes, checksum: 86047341701bdb7e402b715fb158961b (MD5)
Previous issue date: 2009-12-21 / Financiadora de Estudos e Projetos / Fractures of delayed consolidation and fractures with non-union are commonly found in medical practice and are associated with high morbidity and mortality. Within this context, biochemical and biophysical resource have been studied in an attempt enhance bone healing. Among these may be highlighted the use of bioactive materials and low level laser therapy (LLLT). Several studies suggest that both resources are able to stimulate proliferation of osteoblasts and osteogenesis at the fracture site, promoting a greater deposition of bone mass and accelerating the process of consolidation. So the main purpose of the present work was to evaluate the effects of low-intensity laser (λ = 830nm), with fluencies of 60J/cm² and 120J/cm² and a bioactive ceramic, Biosilicato®, used alone or associated on bone consolidation of the tibial fractures in healthy rats. For the study 60 male Wistar rats were randomly divided in 6 groups: group bone defect control (GCF); group bone defect irradiated with LLLT, at 60 J/cm2 (GL60); group bone defect irradiated with LLLT, at 120 J/cm2 (GL120); group bone defect filled with Biosilicate® (GB); group bone defect filled with Biosilicate® , irradiated with LLLT, at 60 J/cm2 (GB60); and group bone defect filled with Biosilicate®, irradiated with LLLT, at 120 J/cm2 (GB120). A low-energy GaAlAs 830nm, CW, 100 mW, 60 and 120 J.cm² was used in this study. The rats were anesthetized by intraperitoneal injection of ketamine and xylazine 2% and a standardized 2.0-mm-diameter bone defect was created by using a motorized drill under copious irrigation with saline solution. Laser irradiation was initiated immediately after the surgery procedure and it was performed every 48 h for 14 days. After 14 day post-surgery, biomechanical analysis revealed no statistical differences between experimental groups. However, the morphological and morphometric analysis showed that the laser, in the two fluencies evaluated showed values statistically higher than control group and the Biosilicate®. Interestingly, the groups treated with Biosilicate® and laser, in two fluencies, showed statistically lower values of newly formed bone in the area of the defect even when compared with the control group. The scanning electron microscopy showed an intense presence of the biomaterial in bone defects of their animals. From the results obtained in this study, we concluded that the low-intensity laser was more effective in the process of bone repair when compared with biomaterial or the two resources associated. / Fraturas com atraso na consolidação e fraturas com não-união óssea são comumente encontradas na prática médica e estão associadas a altos índices de morbidade e mortalidade. Dentro deste contexto, recursos biofísicos e bioquímicos têm sido estudados na tentativa de minimizar o tempo de consolidação óssea. Dentre estes, podem ser destacados o uso dos materiais bioativos e do laser terapêutico de baixa potência (LLLT). Vários estudos sugerem que ambos os recursos são capazes de estimular a proliferação de osteoblastos e a osteogênese no local da fratura, promovendo uma maior deposição de massa óssea e acelerando o processo de consolidação. Diante disso, este estudo teve o objetivo de verificar os efeitos do laser de baixa intensidade (λ = 830nm), com fluências de 60J/cm² e 120J/cm² e de uma vitrocerâmica bioativa, Biosilicato®, utilizados independentemente ou associados na consolidação óssea de fraturas tibiais em ratos saudáveis. Para o estudo, foram utilizados 60 ratos, da linhagem Wistar, distribuídos aleatoriamente nos seguintes grupos: grupo GCF: controle, com fratura e sem tratamento; grupo GL60: fratura tratado com LLLT, fluência de 60J/cm²; grupo GL120: fratura tratado com LLLT, fluência de 120J/cm²; grupo GB: fratura tratado com Biosilicato®; grupo GB60: fratura tratado com Biosilicato® e LLLT, fluência de 60J/cm² e grupo GB120: fratura tratado com Biosilicato® e LLLT, fluência de 120J/cm². Foi utilizado um laser de baixa potência As-Ga-Al, 830nm, CW, 100 mW, 60 e120 J/cm². Os ratos foram anestesiados por injeção intraperitonial de Ketamina e Xilasina. Em seguida, realizou-se defeitos ósseos de 2mm de diâmetro nas tíbias dos animais. A irradiação laser iniciou-se imediatamente após a cirurgia e a cada 48 horas totalizando, 7 aplicações em 14 dias. O sacrifício foi realizado no 14º dia. A análise biomecânica das tíbias não revelou diferenças estatísticas entre os grupos experimentais. No entanto, a análise morfológica e morfométrica revelaram que o grupo laser, nas duas fluências avaliadas, apresentou valores estatisticamente maiores que o grupo controle e o grupo Biosilicato®. Interessante, os grupos tratados com a associação do biomaterial e laser, nas duas fluências, apresentaram valores estatisticamente menores de osso neoformado, mesmo quando comparados ao grupo controle. A microscopia eletrônica de varredura mostrou uma intensa presença do biomaterial nos defeitos ósseos dos respectivos animais. A partir dos resultados obtidos neste estudo, pode-se concluir que o laser terapêutico de baixa potência foi mais eficaz no processo de reparo ósseo quando comparado ao biomaterial, ou mesmo com as duas modalidades de tratamento associadas.
|
246 |
Os efeitos do Biosilicato® e do laser terapêutico de baixa potência no processo de consolidação em tíbias de ratos / The effects of biosilicate® and low level laser therapy on bone consolodation in ratsOliveira, Poliani de 21 December 2009 (has links)
Made available in DSpace on 2016-08-17T18:39:33Z (GMT). No. of bitstreams: 1
2329.pdf: 1318463 bytes, checksum: 91365257065327c5dbaf7e6100a4e5b1 (MD5)
Previous issue date: 2009-12-21 / Universidade Federal de Sao Carlos / Fractures of delayed consolidation and fractures with non-union are commonly found in medical practice and are associated with high morbidity and mortality. Within this context, biochemical and biophysical resource have been studied in an attempt enhance bone healing. Among these may be highlighted the use of bioactive materials and low level laser therapy (LLLT). Several studies suggest that both resources are able to stimulate proliferation of osteoblasts and osteogenesis at the fracture site, promoting a greater deposition of bone mass and accelerating the process of consolidation. So the main purpose of the present work was to evaluate the effects of low-intensity laser (λ = 830nm), with fluencies of 60J/cm² and 120J/cm² and a bioactive ceramic, Biosilicato®, used alone or associated on bone consolidation of the tibial fractures in healthy rats. For the study 60 male Wistar rats were randomly divided in 6 groups: group bone defect control (GCF); group bone defect irradiated with LLLT, at 60 J/cm2 (GL60); group bone defect irradiated with LLLT, at 120 J/cm2 (GL120); group bone defect filled with Biosilicate® (GB); group bone defect filled with Biosilicate® , irradiated with LLLT, at 60 J/cm2 (GB60); and group bone defect filled with Biosilicate®, irradiated with LLLT, at 120 J/cm2 (GB120). A low-energy GaAlAs 830nm, CW, 100 mW, 60 and 120 J.cm² was used in this study. The rats were anesthetized by intraperitoneal injection of ketamine and xylazine 2% and a standardized 2.0-mm-diameter bone defect was created by using a motorized drill under copious irrigation with saline solution. Laser irradiation was initiated immediately after the surgery procedure and it was performed every 48 h for 14 days. After 14 day post-surgery, biomechanical analysis revealed no statistical differences between experimental groups. However, the morphological and morphometric analysis showed that the laser, in the two fluencies evaluated showed values statistically higher than control group and the Biosilicate®. Interestingly, the groups treated with Biosilicate® and laser, in two fluencies, showed statistically lower values of newly formed bone in the area of the defect even when compared with the control group. The scanning electron microscopy showed an intense presence of the biomaterial in bone defects of their animals. From the results obtained in this study, we concluded that the low-intensity laser was more effective in the process of bone repair when compared with biomaterial or the two resources associated. / Fraturas com atraso na consolidação e fraturas com não-união óssea são comumente encontradas na prática médica e estão associadas a altos índices de morbidade e mortalidade. Dentro deste contexto, recursos biofísicos e bioquímicos têm sido estudados na tentativa de minimizar o tempo de consolidação óssea. Dentre estes, podem ser destacados o uso dos materiais bioativos e do laser terapêutico de baixa potência (LLLT). Vários estudos sugerem que ambos os recursos são capazes de estimular a proliferação de osteoblastos e a osteogênese no local da fratura, promovendo uma maior deposição de massa óssea e acelerando o processo de consolidação. Diante disso, este estudo teve o objetivo de verificar os efeitos do laser de baixa intensidade (λ = 830nm), com fluências de 60J/cm² e 120J/cm² e de uma vitrocerâmica bioativa, Biosilicato®, utilizados independentemente ou associados na consolidação óssea de fraturas tibiais em ratos saudáveis. Para o estudo, foram utilizados 60 ratos, da linhagem Wistar, distribuídos aleatoriamente nos seguintes grupos: grupo GCF: controle, com fratura e sem tratamento; grupo GL60: fratura tratado com LLLT, fluência de 60J/cm²; grupo GL120: fratura tratado com LLLT, fluência de 120J/cm²; grupo GB: fratura tratado com Biosilicato®; grupo GB60: fratura tratado com Biosilicato® e LLLT, fluência de 60J/cm² e grupo GB120: fratura tratado com Biosilicato® e LLLT, fluência de 120J/cm². Foi utilizado um laser de baixa potência As-Ga-Al, 830nm, CW, 100 mW, 60 e120 J/cm². Os ratos foram anestesiados por injeção intraperitonial de Ketamina e Xilasina. Em seguida, realizou-se defeitos ósseos de 2mm de diâmetro nas tíbias dos animais. A irradiação laser iniciou-se imediatamente após a cirurgia e a cada 48 horas totalizando, 7 aplicações em 14 dias. O sacrifício foi realizado no 14º dia. A análise biomecânica das tíbias não revelou diferenças estatísticas entre os grupos experimentais. No entanto, a análise morfológica e morfométrica revelaram que o grupo laser, nas duas fluências avaliadas, apresentou valores estatisticamente maiores que o grupo controle e o grupo Biosilicato®. Interessante, os grupos tratados com a associação do biomaterial e laser, nas duas fluências, apresentaram valores estatisticamente menores de osso neoformado, mesmo quando comparados ao grupo controle. A microscopia eletrônica de varredura mostrou uma intensa presença do biomaterial nos defeitos ósseos dos respectivos animais. A partir dos resultados obtidos neste estudo, pode-se concluir que o laser terapêutico de baixa potência foi mais eficaz no processo de reparo ósseo quando comparado ao biomaterial, ou mesmo com as duas modalidades de tratamento associadas.
|
247 |
Efeitos do laser de baixa intensidade e do Scaffold de Biosilicato® no processo de reparação óssea / Efeitos do laser de baixa intensidade e do Scaffold de Biosilicato® no processo de reparação óssea / Abstract: effects of low level laser therapy and Scaffold of Biosilicate® in the process of bone repair / Abstract: effects of low level laser therapy and Scaffold of Biosilicate® in the process of bone repairTim, Carla Roberta 24 February 2011 (has links)
Made available in DSpace on 2016-08-17T18:39:36Z (GMT). No. of bitstreams: 1
3621.pdf: 12488772 bytes, checksum: 3b893af6e3b0ea869fd5eda12f270c8a (MD5)
Previous issue date: 2011-02-24 / Financiadora de Estudos e Projetos / Several resources have been studied in order to accelerate the process of bone repair. Among these resources, bioactive materials and low level laser therapy (LLLT) have gained prominence. Several studies suggest that both resources are able of stimulating osteoblast proliferation and osteogenesis at the fracture site, promoting a greater deposition of bone mass, which is fundamental for the consolidation process. Within this context, this project aimed to assess the effects of LLLT (_ = 830nm), with the fluencies of 120J/cm ² and scaffold Biosilicate®, used associated or not, on consolidation of induced tibial bone defects in the rats. In this study it was used 40 male Wistar rats (3 months ± 250g) divided into four groups (with 10 animals each): group control bone defect without any treatment (GC), group bone defect irradiated with LLLT 830nm (GL); group bone defect treated with implantation of scaffolds Biosilicate ® (GB); group bone defect treated with implantation of scaffolds Biosilicate ® and LLLT 830nm (GBL). The animals were submitted to laser irradiation (Ga-As-Al, 830nm, 100mW) at a single point on the bone defect for eight sessions, on alternate days. The euthanasia of animals occurred at day 15 after surgery, 24 hours after the last laser treatment session. Morphological analysis revealed that the laser group, showed better tissue organization in relation to other groups. Furthermore, morphometric analysis revealed that the irradiated animals showed a higher amount of newly formed bone compared to the other groups. The expression of COX-2 and RUNX-2/CBFA-1 were higher in GB and GBL groups. Also, biomechanical analysis revealed no statistical differences among experimental groups. From the results obtained in this study, it is possible to suggest that both treatments had osteogenic potential 15 days after surgery, but the LLLT was more effective in bone repair when compared to the biomaterials, or even when the two treatment modalities were associated. / Vários recursos têm sido estudados com o intuito de acelerar o processo de reparação óssea. Dentre esses recursos, os materiais bioativos e a Terapia Laser de Baixa Intensidade (LLLT) vêm se destacando, vários estudos sugerem que ambos os recursos são capazes de estimular a proliferação de osteoblastos e a osteogênese no local da fratura, promovendo maior deposição de massa óssea, fundamental para o processo de consolidação. Dentro deste contexto, esse projeto teve como objetivo verificar os efeitos da LLLT (_ = 830nm), com fluência de 120J/cm² e do scaffold de Biosilicato®, utilizados independentemente ou associados na consolidação de defeitos ósseos induzidos em tíbias de ratos. Foram utilizados 40 ratos machos da linhagem Wistar (3 meses de idade ± 250 gramas) distribuídos em 4 grupos experimentais com 10 animais cada: grupo controle com defeito ósseo e sem tratamento (GC); grupo defeito ósseo tratado com Laser 830nm (GL); grupo defeito ósseo tratado com implante de scaffolds de Biosilicato® (GB); grupo defeito ósseo tratado com implante de scaffolds de Biosilicato® e Laser 830nm (GBL). Os animais foram submetidos a irradiação Laser (Ga-As-Al, 830nm, 100mW) em um único ponto sobre o defeito ósseo por oito sessões de tratamento, em dias alternados. A eutanásia dos animais aconteceu no 15º dia após a cirurgia, 24 horas após a última sessão de tratamento Laser. A análise morfológica revelou que o grupo Laser, apresentou melhor organização tecidual em relação os demais grupos experimentais. Além disso, a análise morfométrica evidenciou uma maior quantidade de osso neoformado no grupo tratado com Laser comparado aos animais dos demais grupos. A expressão à COX-2 e a RUNX-2/CBFA-1 mostrou-se mais intensa nos grupos GB e GBL e na análise biomecânica não houve diferença estatística entre os grupos experimentais. A partir dos resultados obtidos neste estudo, pode-se sugerir que ambos os tratamentos apresentaram potencial osteogênico 15 dias após a cirurgia, porém a Terapia Laser de Baixa Intensidade foi mais eficaz no processo de reparo ósseo, quando comparado ao biomaterial, ou mesmo quando as duas modalidades de tratamento foram associadas.
|
248 |
Efeito do laser de baixa intensidade (830nm) associado ao exercício em ratos obesos exógenosAquino Junior, Antonio Eduardo de 29 June 2012 (has links)
Made available in DSpace on 2016-08-17T18:39:43Z (GMT). No. of bitstreams: 1
4546.pdf: 1425680 bytes, checksum: 4b119fcf0d7406ed02ba08a4e86ae082 (MD5)
Previous issue date: 2012-06-29 / Universidade Federal de Sao Carlos / Obesity is a multifactorial disease that has endogenous and exogenous origin and this includes 95% of all cases. One of the treatments takes into account the negative energy balance, which is the relationship between decreasing consumption and increased caloric expenditure. The aim of this study was to evaluate the systemic effects of low intensity laser associated the moderate exercise of swimming in obesity animals exogenous. Male Wistar rats were randomly distributed in eight groups (N=64). SC (sedentary chow-diet) SCL (sedentary chow-diet laser), EC (exercised chow-diet), ECL (exercised chow-diet laser), SH (sedentary high-fat diet), SHL (sedentary highfat diet laser), EH (exercised high-fat diet) and EHL (exercised high-fat diet laser). The exercise protocol followed parameters of Damaso, 1996. The irradiation parameters was 100mW, 60mW/cm2,and the Treatment time was 47s applied to both hind feet of the animals immediately after the exercise. Significant differences were found in groups with association between laser and exercise, in special the biochemical parameters (total cholesterol, triglycerides and LDL) as well as modification of the adipocytes area by morphometric analysis. The advent of new possibilities in the treatment of obesity and associated diseases such as dyslipidemia is crucial upon the pattern of eating behavior that modern society is willing to use. The therapy show to be a possible additional tool in treatment of obesity. / A obesidade é uma doença multifatorial que possui origem endógena e exógena e esta compreende 95% do total de casos. Um dos tratamentos leva em conta o balanço energético negativo, que é a relação entre diminuição do consumo e aumento do gasto calórico. O objetivo deste estudo foi analisar os efeitos sistêmicos do laser de baixa intensidade associado ao exercício moderado de natação em animais obesos exógenos. Foram utilizados 64 animais divididos em 8 grupos. Foi induzida obesidade por meio de dieta hipercalórica três semanas antes do início do projeto. Os grupos foram descritos como: SP (sedentário padrão), SNL (sedentário padrão laser), EP (exercitado padrão), EPL (exercitado padrão laser), SH (sedentário hipercalórico), SHL (sedentário hipercalórico laser), EH (exercitado hipercalórico) e EHL (exercitado hipercalórico laser). O protocolo de exercício seguiu parâmetros de Dâmaso, 1996. O parâmetro de irradiação foi de 100mW, 60mW/cm2, tempo de tratamento de 47s e aplicado nas duas patas traseiras dos animais logo após o exercício. A associação entre fototerapia e exercício de intensidade moderada em ralação à situação de obesidade experimental pela dieta foi capaz de promover a reversão de quadros de aumento celular, diminuição dos valores lipídicos séricos, tendo influência positiva quanto à diminuição do delta da massa corporal. O surgimento de novas possibilidades no tratamento da obesidade e de doenças associadas a ela, como por exemplo, as dislipidemias, são imprescindíveis mediante o padrão de comportamento alimentar que a sociedade atual se dispõe a utilizar. Assim, a possibilidade de um modelo clínico torna-se interessante mediante adequação da tecnologia empregada no experimento, para a prática clínica multidisciplinar.
|
249 |
Efeitos do laser de baixa intensidade e do exercício físico aeróbio sobre a regeneração do músculo tibial anterior de ratosAdabbo, Mayna 17 February 2012 (has links)
Made available in DSpace on 2016-08-17T18:39:50Z (GMT). No. of bitstreams: 1
5657.pdf: 4882476 bytes, checksum: ecaf13ba1de9758d6f63d658eefadedc (MD5)
Previous issue date: 2012-02-17 / Financiadora de Estudos e Projetos / The objective of this study was to analyze the effects of Low level laser therapy (LLLT) associated with aerobic physical exercise on the muscle regeneration process during 2 periods of rest after of the muscle injury in rats. Forty rats were divided into 2 groups (A and B), and 4 subgroups each: GC (Control Group) - cryolesioned untreated; GE (Exercise Group) - cryolesioned treated with aerobic physical exercise; GL (Laser Group) - cryolesioned treated with laser; GEL (Exercise and Laser Group) - cryolesioned treated with laser and aerobic physical exercise. The tibialis anterior (TA) of the middle belly was injured by a cooling iron bar (cryoinjury). The animals in Group A remained at rest for 3 days, while Group B remained at rest for 7 days. The laser parameters were: 780 nm, 15 mW, during 10 s, 0.152 J e 3.8 J/cm². Physical exercises with or without laser were performed during 5 days, each session lasting 12 min at a treadmill velocity of 17 m/min. The AT muscles were removed for histological and morphometric analysis. The damage area was significantly smaller for the GEL, when remained at rest for 3 and 7 days respectively, (4.4±0.42 % and 3.5±0.14 %, p < 0.05) compared to GL (18.6±0.64 % and 7.5±0.13 %), GE (21±0.26 % and 8.7±0.32 %) and GC (23.9±0.37 % and 21.4±0.38 %). In addition, the number of blood vessels were significantly higher for the GEL, when remained at rest for 3 and 7 days respectively, (71.2±13.51 % and 104.5±11,78, p < 0.05) compared to the GL (60.6±11.25 and 93.5±16.87), GE (51.6±7.3 and 93.8±15.1) and GC (34.4±2.54 and 65.7±14.1). Therefore, the laser applied before the physical exercise on the treadmill stimulated an angiogenesis and accelerated the process of muscle regeneration. / O objetivo deste estudo foi investigar os efeitos da laserterapia e do exercício físico aeróbio sobre a regeneração do músculo tibial anterior de ratos com diferentes períodos de repouso após a lesão. Foram utilizados para este estudo 40 ratos Wistar que foram submetidos à cirurgia para criolesão no músculo tibial anterior (TA). Os animais foram divididos em 2 grupos (A e B). Os animais do Grupo A permaneceram em repouso por 3 dias, enquanto o Grupo B permaneceu em repouso por 7 dia. Cada grupo foi subdividido em 4 grupos: o GC (Grupo Controle) lesionado e não tratado; o GE (Grupo Exercício) lesionado e tratado com exercício físico na esteira; o GL (Grupo Laser) - lesionado e tratado com laser e; o GEL (Grupo Exercício e Laser) lesionado e tratados com exercício físico na esteira e laser. Os parâmetros do laser utilizado foram 780 nm, 15 mW de potência, tempo de 10 s, com energia de 0,125J e dose de 3,8 J/cm2. O exercício físico com ou sem laser foi realizado durante 5 dias, cada sessão teve a duração de 12 minutos e a velocidade da esteira foi 17 m/min. Os músculos TA foram retirados para análise histológica e morfométrica. A área de lesão foi significativamente menor no GEL, quando o repouso foi mantido por 3 e 7 dias respectivamente, (4,4±0,42 % e 3,5±0,14 %, p < 0.05) comparado ao GL (18,6±0,64 % e 7,5±0,13 %), GE (21±0,26 % e 8,7±0,32 %) e GC (23,9±0,37 % e 21,4±0,38 %). Ainda, o número de vasos sanguíneos foi significantemente maior no GEL, quando o repouso foi mantido por 3 e 7 dias respectivamente, (71,2±13,51 % e 104,5±11,78, p < 0.05) comparado ao GL (60,6±11,25 e 93,5±16,87), GE (51,6±7,3 e 93,8±15,1) e GC (34,4±2,54 e65,7±14,1). Portanto, o laser aplicado antes do exercício físico na esteira estimulou a angiogênese e acelerou o processo de regeneração muscular.
|
250 |
Efeitos imediatos da laserterapia sobre o desempenho neuromuscular ap?s fadiga muscular induzida: ensaio cl?nico controlado, randomizado e cegoSilva, Rodrigo Marcel Valentim da 13 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:16:19Z (GMT). No. of bitstreams: 1
RodrigoMVS_DISSERT.pdf: 1040063 bytes, checksum: 766940b0097dd943c6d99b09073ebe7b (MD5)
Previous issue date: 2012-12-13 / The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 ?/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 ?/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue / O objetivo desse estudo foi investigar os efeitos imediatos da laserterapia sobre o desempenho neuromuscular em sujeitos saud?veis, ap?s um protocolo de fadiga muscular. Trata-se de um ensaio cl?nico, controlado, randomizado e cego, no qual participaram 80 volunt?rios de ambos os g?neros, ativos, com faixa et?ria entre 18 ? 28 anos. Inicialmente os volunt?rios realizaram uma avalia??o inicial (AV1), utilizando a eletromiografia do b?ceps braquial, associado ? avalia??o por dinamometria isocin?tica, com 5 contra??es conc?ntricas (60?/s) para flex?o de cotovelo. Os sujeitos foram alocados randomicamente em 4 grupos: o G1 (n=20), controle, G2 (n=20), placebo, o G3 (n=20), laser pr?-fadiga e o G4 (n=20), laser p?s-fadiga. O protocolo de fadiga muscular possu?a incluiu 30 contra??es isocin?ticas conc?ntricas (120?/s). Foi utilizado um laser de 808 nm, pot?ncia de 100 mW, energia total de 20 J, aplicado no ventre do m?sculo b?ceps braquial. Ap?s as interven??es os volunt?rios realizaram uma avalia??o final (AV2). Foi aplicado o teste de Anova two-way, com post-hoc de Turkey, com n?vel de signific?ncia de 5%. N?o existiu diferen?a significativa na avalia??o eletromiogr?fica. Na avalia??o dinamom?trica observou-se uma queda do Pico de Torque, Pico de torque normalizado pelo peso corporal (p<0,001) e Pot?ncia m?dia (p<0,05), entre as avalia??es inicial e final no grupo controle. Observou-se diferen?a significativa entre o controle e os demais grupos, em rela??o ao pico de torque (p<0,05), pico de torque pelo peso corporal (p<0,001) e pot?ncia m?dia (p<0,05). Assim, a laserterapia de baixa intensidade n?o alterou o desempenho neuromuscular ap?s a fadiga nesses sujeitos
|
Page generated in 0.051 seconds