• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 18
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 327
  • 168
  • 87
  • 83
  • 82
  • 66
  • 63
  • 58
  • 57
  • 41
  • 39
  • 33
  • 30
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Calibre vascular retiniano e a pressão arterial medida por monitoramento ambulatorial da pressão arterial

Pakter, Helena Messinger January 2010 (has links)
É bem conhecido que alterações vasculares iniciam como um processo silencioso e assintomático. A identificação precoce de anormalidades vasculares na retina em pacientes assintomáticos pode permitir a detecção de pacientes em risco de desenvolver DCV. Por prover visualização direta do leito vascular, a retina pode ser estudada não invasivamente mostrando o grau de acometimento da microcirculação. Avanços nas técnicas de fotografia retiniana e de análise digital de imagem tem permitido a mensuração objetiva de alterações vasculares da retina. Com isso, é possível quantificar anormalidades na microvasculatura retiniana, imprescindível para o estudo da fisiopatologia da hipertensão arterial sistêmica, bem como para a avaliação da associação com doença cardiovascular. Um software desenvolvido pela autora desta tese e colaboradores é capaz de medir calibre de arteríolas e vênulas de retinografias digitalizadas. Esse software, nomeado Retinal Analyser System (RAS), foi atualizado e houve a inclusão e testagem de um fator de escala ou calibração, apresentado no Artigo 1 dessa tese. Os métodos de análise de imagens da retina utilizados para medir calibre dos vasos retinianos não determinam exatamente o que está sendo medido. Assim, havia necessidade de investigar se o calibre medido no software RAS corresponde ao lúmen vascular somente ou se inclui a parede vascular. O Artigo 2 dessa tese apresenta a comparação de medidas de calibre de vasos retinianos, em retinografias coloridas com angiografias fluoresceínicas. Nesse artigo concluímos que, como as diferenças encontradas entre os dois métodos foram muito pequenas, o método microdensitométrico mede o lúmen vascular. Os calibres vasculares retinianos avaliados quantitativamente por métodos digitalizados tem mostrado uma associação significativa com incidência e gravidade da hipertensão arterial casual. No entanto, nas últimas décadas, tem sido discutido o valor da medida casual da pressão arterial para fins prognósticos. Em função da variação contínua da pressão arterial, de momento a momento, de acordo com as atividades do indivíduo, novos métodos podem complementar a avaliação através de medidas repetidas da pressão arterial, permitindo a detecção da pressão arterial usual. Tendo em vista essas considerações, o Artigo 3 dessa tese avaliou a associação entre os diferentes parâmetros da pressão arterial, medida pela MAPA, e os calibres vasculares retinianos. A relação entre pressão arterial e calibre arteriolar e venular da retina no momento da obtenção retinografia também foi estudada. Demonstramos que a pressão diastólica média das 24 horas, da vigília e do sono teve associação inversa e significativa com calibre arteriolar e razão arterio-venosa, mas não com calibre venular. A pressão arterial medida na hora da retinografia não mostrou associação com o calibre dos vasos retinianos. Assim concluímos que a associação entre o calibre arteriolar dos vasos retinianos e a pressão arterial não é influenciada pela variação instantânea da pressão arterial e, provavelmente, depende de lesões histológicas da parede arteriolar secundária à hipertensão sustentada. Através da MAPA também é possível avaliarmos a variação temporal da pressão arterial ao longo de um período de 24 horas, e assim estudar o ritmo circadiano e a ritimicidade da pressão arterial. Uma maneira de analisar a ritimicidade da pressão arterial é através do método Cosinor, um método de análise de regressão periódica, baseada na adaptação da função do coseno, para valores da pressão arterial com período de 24 horas. O método Cosinor gera, em cada elemento (indivíduo ou população), os seguintes parâmetros de validação do ritmo circadiano: MESOR (sigla em inglês para média do ritmo ajustada estatísticamente), acrofase e amplitude. O estudo do ritmo circadiano da pressão arterial, avaliado pela da análise de cosinor, e sua associação com os calibres vasculares retinianos, resultou no artigo 4 dessa tese. Nesse artigo, mostramos que o MESOR associa-se significativa e inversamente com calibre arteriolar, com uma magnitude de 0.8 a 1 micron de redução no calibre para um aumento de 10 mmHg do MESOR da pressão arterial. O calibre venular não mostrou associação com o MESOR. Também usamos a análise de Cosinor para população e avaliamos as diferenças nos ritmos da pressão arterial entre as populações do primeiro e dos demais quintis de calibre vascular. Através desta análise observamos que amplitude e acrofase da pressão arterial são estatisticamente diferente entre as populações do primeiro e demais quintis de calibre venoso, mas não arteriolar. Em resumo, enquanto o MESOR está associado ao calibre arteriolar, a amplitude e a acrofase estão associadas ao calibre venular. Concluindo, essa tese mostra, através de seus 4 artigos, a aplicação do software RAS para medida de calibres vasculares retinianos e a associação dessas medidas com pressão arterial, em uma população de pacientes hipertensos. A associação entre o calibre vascular retiniano, a pressão arterial medida 24 horas e o seu ritmo, demonstrada nessa tese, fortalece a hipótese que a avaliação da microvasculatura retiniana pode ser um marcador clínico importante de lesão em órgão. / It is well known that vascular changes begin as a silent and asymptomatic process. Early identification of retinal vascular abnormalities in asymptomatic patients may allow the detection of patients at risk. By providing unique visualization of the vascular bed, the retina can be studied no invasively and show the degree of microcirculation involvement. Advances in techniques of retinal photography and digital image analysis have allowed objective measurement of retinal vascular changes. Thus, it is possible to quantify abnormalities in the retinal microvasculature, essentially to study hypertension pathophysiology, and to assess its association to cardiovascular disease. Software developed by our research group is able to measure the caliber of arterioles and venules of digitized fundus. This software, named Retinal Analyzer System (RAS), has been updated by including and testing a scale factor, presented in Article 1 of this thesis. The current methods of image analysis used to measure the caliber of retinal vessels do not determine exactly what is being measured. Thus there was need to investigate whether the caliber measured in RAS software corresponds to the vascular lumen only or whether it includes the vascular wall. Article 2 of this thesis presents a comparison of the measurements of retinal vessels calibers in color fundus photography to those in fluorescein angiography. In this article we show that the differences found between the two methods were very small, and concluded that the microdensitometry method measures mainly the vascular lumen. The retinal vascular calibers measured quantitatively by microdensitometric methods have shown a significant association with incidence and severity of hypertension. However, studies evaluating these associations are based on casual blood pressure and, in recent decades, it has been discussed the value of casual blood pressure measurement. In light of continuous variation in blood pressure from moment to moment, according to the individual's activities, new methods can complement the assessments through repeated measurements of blood pressure, allowing the detection of usual blood pressure. Given these considerations, Article 3 of this thesis examined the association between different parameters of the blood pressure measured by ABPM, and retinal vascular caliber. The relationship between blood pressure at the time of retinography acquisition and retinal arteriolar and venular caliber was also studied. We show that the mean 24 hours, daytime and night time diastolic blood pressure were significantly and inversely associated with arteriolar caliber and arteriovenous ratio, but not with venular caliber. The pressure measured at the time of acquisition of the fundus showed no association with the caliber of retinal vessels, thus the association between arteriolar retinal vessels caliber and blood pressure is not influenced by instantaneous variation of blood pressure and probably depends of histological damage of arteriolar wall secondary to sustained hypertension. Using ABPM is also possible to evaluate the temporal variation of blood pressure over a period of 24 hours, and then study the circadian rhythm of blood pressure. One way to analyze the blood pressure rhythm is using the Cosinor method, a method of periodic regression analysis, based on the adaptation of the cosine function, for values of blood pressure with 24-hour period. The method Cosinor generates the following validation parameters of the circadian rhythm: MESOR (acronym for "Midline Estimated Statistic Of Rhythm"), acrophase and amplitude. The study of circadian rhythm of blood pressure, as assessed by analysis COSINOR and its association with retinal vascular caliber, resulted in Article 4 of this thesis. In this paper we show that MESOR is associated significantly and inversely with arteriolar caliber, with a magnitude of 0.8 to 1 micron reduction to an increase of 10 mmHg of blood pressure MESOR. The venular caliber was not associated with MESOR. We also use the Cosinor analysis to study differences in the rhythms of blood pressure among populations in the first quintile and the rest quintiles of vascular caliber. Through this analysis we found that amplitude and acrophase of blood pressure were statistically different between the populations of the first and the other quintiles of venous caliber, but not arterioles. In conclusion, this thesis shows, through its four articles, the application of RAS software to measure retinal vascular caliber and the association of these measurements with blood pressure in a population of hypertensive patients. The association between retinal vascular calibers, blood pressure measured 24 hours and rhythm, as demonstrated in this thesis, strengthens the hypothesis that assessment of the retinal microvasculature may be an important clinical marker of organ damage.
162

Eficácia da monitorização residencial da pressão arterial no controle da hipertensão : um ensaio clínico randomizado com monitorização ambulatorial da pressão arterial

Silva, André Luis Ferreira da January 2008 (has links)
Título: Eficácia da monitorização residencial da pressão arterial no controle da hipertensão: um ensaio clínico randomizado com monitorização ambulatorial da pressão arterial Introdução: A hipertensão arterial é o principal fator de risco para doenças cardiovasculares e sua prevalência é elevada tanto nos países desenvolvidos quanto naqueles em desenvolvimento. Apesar da existência de opções terapêuticas farmacológicas e não farmacológicas eficazes, as taxas de controle da hipertensão arterial ainda são insatisfatórias em todo o mundo. A má-adesão à prescrição terapêutica é um fenômeno complexo e pouco compreendido que contribui para as baixas taxas de controle da hipertensão. Diferentes estratégias foram testadas em ensaios clínicos com o objetivo de melhorar a adesão terapêutica, com resultados variados. No entanto, o panorama geral da adesão à medicação anti-hipertensiva não mudou significativamente. A monitorização residencial da pressão arterial (MRPA) com dispositivos oscilométricos automáticos tem sido proposta como um instrumento capaz de melhorar a adesão e influenciar no controle da hipertensão, mas seu real efeito ainda é debatido. Objetivo: avaliar a eficácia da MRPA no controle terapêutico (aferido por MAPA de 24h) de pacientes hipertensos não controlados, em uso de anti-hipertensivos, comparativamente ao acompanhamento usual no consultório médico. Métodos: O presente relato trata de análise interina de um estudo em andamento. Este ensaio clínico prospectivo controlado está sendo realizado no ambulatório de hipertensão do Hospital de Clínicas de Porto Alegre, onde 62 indivíduos hipertensos não controlados, em tratamento farmacológico, foram randomizados para 2 grupos: MRPA ou cuidados habituais. Para participação no estudo, era necessário que a pressão arterial (PA) estivesse elevada tanto no consultório (PA > 140/90 mmHg) quanto na monitorização ambulatorial de 24h (MAPA média de 24h >130/80 mmHg). Os pacientes alocados para a intervenção receberam um dispositivo oscilométrico validado (OMROM 705- CP) e foram treinados para a aferição residencial da pressão arterial, além de receberem orientações não farmacológicas para manejo da hipertensão. O grupo controle foi submetido a consultas médicas de acordo com cronograma semelhante ao do grupo intervenção, recebendo as mesmas orientações não farmacológicas. Não houve ajuste dos medicamentos durante o estudo. Após um seguimento de 60 dias, os participantes foram submetidos a uma segunda MAPA de 24h para aferição do desfecho principal, definido como a variação nos parâmetros da MAPA entre a linha de base e o encerramento. Resultados: Após ajuste para as respectivas pressões na linha de base e para a idade, identificou-se uma tendência de maior queda nas pressões sistólicas e diastólicas no grupo MRPA, atingindo significância estatística para a PA diastólica noturna (7,5 versus 0,9 mmHg, P = 0,01). Conclusão: MRPA parece melhorar o controle da hipertensão arterial de indivíduos em tratamento medicamentoso independentemente do ajuste de medicamentos. O mecanismo para tal efeito não é completamente compreendido, mas possivelmente envolva melhora na adesão aos medicamentos e nos hábitos de vida. A análise final desse estudo, com uma maior amostra estudada, é necessária para comprovar a tendência identificada.
163

Cardiotocografia ante-parto e percepção materna dos movimentos fetais na avaliação do bem estar fetal em gestantes diabeticas

Pereira, Belmiro Gonçalves, 1955- 27 November 1996 (has links)
Orientador: Anibal Faundes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-22T05:05:49Z (GMT). No. of bitstreams: 1 Pereira_BelmiroGoncalves_D.pdf: 1535645 bytes, checksum: 0d0fcf1ee8c166a1310bd7bab516e569 (MD5) Previous issue date: 1996 / Resumo: A avaliação das condições fetais em diabéticas continua sendo fator preocupante na assistência pré-natal. O diagnóstico correto das provas de vitalidade fetal ainda é problema, principalmente quando se trata de permitir que a gestação prossiga. Estudamos o "Nonstress test" (NST) de 214 gestações de diabéticas atendidas no Pré-Natal Especializado (PNE) do Centro de Atenção Integral à Saúde da Mulher (CAISM), entre junho de 1988 e maio de 1996. Estudamos também o Estímulo Acústico (EA), isoladamente, e depois associado ao NST. Classificamos estes exames como reativos (R), hiporreativos (HR) ou não reativos (NR), de acordo com a variação da freqüência cardíaca aos movimentos fetais ou ao EA. Avaliamos ainda a percepção materna dos movimentos fetais (PMMF) de 209 dessas gestações, classificados como "normais" quando maiores que sete em até uma hora e "anormais' se isso não ocorreu. Comparamos estas variáveis (independentes) com os resultados perinatais, como sinais de sofrimento fetal (SF) à prova de Pose ou intra-parto, Apgar de 10 e 50 minutos de vida menor que sete e diagnóstico neonatal de anóxia (variáveis dependentes). Calculamos os valores de sensibilidade, especificidade, valor preditivo positivo (VPP) e valor preditivo negativo (VPN). Posteriormente, controlamos tais resultados pelas variáveis hipertensão, controle metabólico e idade gestacional. As diferenças estatísticas for~m avaliadas pelo teste de X2 para comparação de testes de diagnóstico!, e considerou-se como significativa a diferença que correspondeu a p<0,05. Cerca de 18% dos NST foram NR e cerca de 50% deles se tornaram reativos após o EA. Estes exames apresentaram boa especificidade, próxima a 90% e VPN entre 90 e 100%, enquanto a sensibilidade e VPP variaram bastante, dependendo da condição que se pretendia predizer. Não foram encontradas diferenças estatísticas da- capacidade de diagnóstico para variáveis perinatais entre a PMMF e os métodos monitorizados, exceto para SF que foi melhor diagnosticado pelo NSTIEA. Não foram encontradas diferenças quando se controlou por hipertensão, controle metabólico e idade gestacional / Abstract: Fetal well-being in pregnant diabetics is a continous concern during ante-natal care. The correct diagnosis of fetal surveillance tests remain a problem, considering the perspective of allowing pregnancy to continue. Non-stress test (NST) was studied on 214 diabetic pregnancies at the High Risk Prenatal Care at the Centro de Atenção Integral à Saúde da Mulher (CAISM), between June 1988 and May 1996. Vibro-acustic Stimulation (EA) was also studied, either isolated or in association to NST. Tests were classified as reactive (R), hiporeactive (HR) or. not-reactive (NR), according to the characteristics of fetal heart frequency variability in response to fetal movements or EA. Maternal perception of fetal movements (PMMF) of 209 of these pregnancies was also studied. This test was classified as normal when seven or more movements were perceived by the mother within one hour and abnormal when less than seven fetal movements were perceived within the same period of observation. The results of these tests (independent variables) were compared with the signs of fetal distress (SF) during labor or a occitocin-induced contraction stress test, with Apgar scores bellow seven at the 1st and 5th minutes of life or with neonatal diagnosis of hipoxia (dependent variables). Sensitivity, specificity, positive predictive value (VPP) and negative predictive value (VPN) were calculated. These results were then controlled bythe variables: hypertension, metabolic control and gestacional age. Statistical" differences between diagnostic tests, were calculated by Chi-square test and considered significative for p<Ok,05. Some 18% of the NST tests were NR and 50% of them became R after EA. These tests had specificity around 90% and VPN between 90% and 100%, whereas sensitivity and VPP varied depending on the condition evaluated. No statistical differences were observed for the diagnosis of perinatal variables between the PMMF and electrically monitored methods, except for fetal distress that was better diagnosed by NST/EA. No differences were observed when hypertension, metabolic control or gestational age were used as controlled variables / Doutorado / Tocoginecologia / Doutor em Tocoginecologia
164

Análise contínua de medidas de cateter de artéria pulmonar volumétrico, ecotransesofágico, variações da pressão arterial sistêmica e marcadores de hipoperfusão tissular no choque hemorrágico em suínos / Continuous analyses of pulmonary, volumetric artery catheter parameters, transesophageal echocardiography, pressure pulse variation, and biomarkers of tissue hypoperfusion during hemorrhagic shock in swine. Experimental study in swines

Marcos Antonio de Oliveira 25 November 2009 (has links)
INTRODUÇÃO: Diferentes parâmetros hemodinâmicos, incluindo os indicadores estáticos de pré-carga cardíaca como o índice de volume diastólico final ventrículo direito (IVDFVD) e parâmetros dinâmicos como a variação de pressão de pulso (VPP) têm sido usados na tomada de decisão para considerar o processo da expansão volêmica em pacientes em estado grave. O objetivo deste estudo foi comparar a reanimação por fluidos guiados tanto por VPP ou IVDFVD após choque hemorrágico induzido experimentalmente. MÉTODO: vinte e seis suínos anestesiados e ventilados mecanicamente foram alocados em três grupos: controle (Grupo I), VPP (Grupo II) e IVDFVD (Grupo III). Foi induzido choque hemorrágico por retirada de sangue até atingir a pressão arterial média de 40mmhg, que foi mantida por 60 minutos. Parâmetros foram medidos no tempo basal (B), no tempo do choque (Choque 0), sessenta minutos depois do choque (Choque 60), imediatamente depois da ressuscitação com hidroxietilamido 6% (130/0. 4) (R0), uma hora (R60) e duas horas (R120) depois ressuscitação. Os pontos de avaliação da reanimação por fluidos foram determinados pelo retorno aos valores basais iniciais de VPP e IVDFVD. A análise estatística dos dados foi baseada em ANOVA para medidas repetidas seguidos pelo teste de Bonferroni (P<0.05%). RESULTADOS: O volume e tempo para ressuscitação foram maiores no grupo III do que no grupo II (Grupo III = 1305±331ml e Grupo II = 965±245ml; p<0.05 e Grupo III = 24.8± 4.7min e Grupo II = 8.8 ± 1.3 min, p<0.01, respectivamente). Todos os parâmetros estáticos e dinâmicos, bem como os biomarcadores de oxigenação tecidual foram afetados pelo choque hemorrágico e quase todos os parâmetros foram totalmente restaurados após a reanimação em ambos os grupos. CONCLUSÃO: Neste estudo em modelo de choque hemorrágico, a reanimação guiada pelo VPP utilizou menor quantidade de fluido e menor quantidade de tempo do que quando guiado por IVDFVD derivado de cateter de artéria pulmonar. / INTRODUCTION: Different hemodynamic parameters, including static indicators of cardiac preload as right ventricular end-diastolic volume index (RVEDVI) and dynamic parameters as pulse pressure variation (PPV) have been used in the decision-making process regarding volume expansion in critically ill patients. The objective of this study was to compare fluid resuscitation guided by either PPV or RVEDVI after experimentally-induced hemorrhagic shock. METHODS: 26 anesthetized and mechanically ventilated pigs were allocated into control (Group-I), PPV (Group-II) and RVEDVI (Group- III). Hemorrhagic shock was induced by blood withdrawal to target mean arterial pressure of 40mmHg, maintained for 60 minutes. Parameters were measured at baseline, time of shock, sixty minutes after shock, immediately after resuscitation with hydroxyethyl starch 6% (130/0.4), one hour and two hours thereafter. The endpoint of fluid resuscitation was determined as the baseline values of PPV and RVEDVI. Statistical analysis of data was based on ANOVA for repeated measures followed by the Bonferroni test (P<0.05). RESULTS: Volume and time to resuscitation were higher in Group-III than in Group-II (Group-III = 1305±331ml and Group-II = 965±245ml; p<0.05 and Group-IIII = 24.8±4.7min and Group-II = 8.8±1.3 min, p<0.05, respectively). All static and dynamic parameters and biomarkers of tissue oxygenation were affected by hemorrhagic shock and nearly all parameters were restored after resuscitation in both groups. CONCLUSION: In the proposed model of hemorrhagic shock, resuscitation to the established endpoints was achieved within a smaller amount of time and with less volume when guided by PPV than when guided by pulmonary artery catheter-derived RVEDVI.
165

Fatores associados às concentrações séricas de fármacos utilizados no tratamento da tuberculose

Rodrigues, Ana Jacqueline Coelho, 92-99181-4774 31 August 2016 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-08-24T14:22:04Z No. of bitstreams: 2 Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-08-24T14:22:17Z (GMT) No. of bitstreams: 2 Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-08-24T14:22:17Z (GMT). No. of bitstreams: 2 Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-08-31 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Introduction: Tuberculosis (TB) is an infectious disease of high prevalence in Brazil. Thus, drug treatment used in the country is standardized by the TB treatment Basic Scheme and consists of rifampicin, isoniazid, pyrazinamide and ethambutol. The occurrence of low therapeutic levels of these drugs is reported in several people and many factors may contribute to this outcome. Therefore, this study aimed to determine the serum concentrations of antituberculosis drugs, and relating sociodemographic and laboratory variables with the levels obtained in samples from patients treated at a referral center in Manaus. Materials and Methods: This was an analyticalobservational cross-sectional study. The study population consisted of patients under treatment for TB treated at a referral center in the city of Manaus. The variables were compared between patients with low and normal serum using the chi-square test for categorical variables and Student's t test for continuous variables. For all the tests performed in this study, the significance level was 0.05. Results: Of 222 patients, 40.9% of patients had reduced serum levels for one of the tested drugs, and the prevalence of low more significant therapeutic levels were to isoniazid (60.8%) and rifampin (58.6%). Singles was found association with low serum concentrations of Isoniazid (p = 0.044), people with high school/graduate education (p = 0.028) and alcoholics (p = 0.038). Furthermore, in the case of Rifampicin, was association of people with a high school/graduate and lower therapeutic drug levels (p = 0.063). ANOVA analysis was performed and there was no association of the NAT2 genotypes and the serum concentrations with statistical significance (p <0.05). Conclusion: The presence of low concentrations of first-line drugs used to treat TB was found in a significant proportion of the population under study. Additional studies should be conducted to assess the impact of pharmacogenetics and adherence to treatment in these results, as well as to investigate the influence of low concentrations in treatment outcome. / Introdução: A tuberculose (TB) é uma doença infectocontagiosa de alta prevalência no Brasil. Desta forma, o tratamento medicamentoso empregado no país é padronizado pelo Esquema Básico de Tratamento da TB e é constituído por Rifampicina, Isoniazida, Pirazinamida e Etambutol. A ocorrência de baixos níveis terapêuticos desses fármacos no soro é relatada nas mais diversas populações e diversos fatores podem contribuir para este fato. Portanto, este estudo teve como objetivo determinar os fatores associados às concentrações séricas dos fármacos antituberculose, além de determinar fatores sócio demográficas e laboratoriais com esses níveis séricos obtidos em amostras de pacientes atendidos em uma unidade de referência em Manaus. Materiais e Métodos: Tratou-se de um estudo analítico-observacional de corte transversal. A população de estudo foi composta por pacientes sob tratamento da tuberculose atendidos em uma unidade de referência da cidade de Manaus. As variáveis foram comparadas entre os pacientes com níveis séricos baixos e normais usando o teste do qui-quadrado (χ²) para variáveis categóricas e teste t de Student para variáveis contínuas. Para todos os testes realizados neste estudo, o nível de significância adotado foi de 0,05. Resultados: Dos 222 pacientes, 40,9% dos pacientes apresentaram níveis séricos reduzidos para um dos fármacos testados, sendo que as prevalências de baixos níveis terapêuticos mais expressivas foram para Isoniazida (60,8%) e Rifampicina (58,6%). Foi verificada associação de solteiros com baixas concentrações séricas de Isoniazida (p=0,044), de pessoas com ensino médio/superior (p=0,028) e de etilistas (p=0,038). Além disso, no caso da Rifampicina, foi verificada associação de pessoas com escolaridade ensino médio/superior e baixos níveis terapêuticos deste fármaco (p=0,063). Foi realizada análise de variância e não houve associação dos genótipos de NAT2 e as concentrações séricas com significância estatística (p<0,05). Conclusão: A ocorrência de baixas concentrações séricas dos fármacos de primeira linha utilizados para o tratamento da TB foi constatada na população em estudo. Estudos adicionais devem ser realizados para avaliar o impacto da farmacogenética e da adesão ao tratamento nestes resultados, bem como investigar a influência das baixas concentrações no desfecho do tratamento.
166

Diagnóstico da estrutura urbana e da área de preservação permanente (APP) em uma ocupação desordenada na zona leste da cidade de Manaus, Amazonas

Ferreira, Alan dos Santos 17 December 2012 (has links)
Made available in DSpace on 2015-04-13T12:17:14Z (GMT). No. of bitstreams: 1 alan dos santos.pdf: 274316 bytes, checksum: c6654ea42d94e8445f97fc48a971c0a2 (MD5) Previous issue date: 2012-12-17 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / With the process of urban expansion spurred by population growth and development of productive and commercial activities, among other factors, have brought many problems to cities and their populations. As a consequence of inadequate planning of land use, this expansion has produced a degraded urban environment, with great influence on the quality of life of the population, the main constraints of this disorderly occupation demographic and socioeconomic determinants. In this sense, we studied the structure of an urban area in the East Zone disorderly occupation of the city of Manaus. The selected areas were communities Jorge Teixeira 3rd stage, Bairro Novo, Arthur Virgílio Neto and João Paulo, members of the Urban Design Unit UES (neighborhood) Jorge Teixeira, as Urban Environmental Master Plan of 2008 the city of Manaus. For the analysis and implementation of research, management and tabulation of the data for manipulation of the registration information and spatial attributes, we used the standardization of shapefile files (Shp), the software used were the ArcGis 9.3 and Spring 4.1, GIS tools , used the digital map of the urban area of Manaus, gerreferenciado in geographic projection systems DATUM SAD 69, and Quickbird satellite images aerophotogrammetric 2008 and 2010. The study communities were visited spot in the second half of 2007. The results show similar characteristics to one with the other due to lack of planning and structuring and planning for construction of homes, shops, streets, water supply systems, network systems, sanitary sewer collection and industrial trash collection. Lots of four communities in the study did not meet the guidelines of retreat and leaves the sides of the streets axles, distance between the neighboring lots, maximum building area, area for permeabilization, and consequently, the area of blocks and lots intended for different urban activities , and even industrial trades, disobeying the Master Plan Environmental and Urban Manaus. It follows that in the communities studied, by its geographical position and strategic situations present environmental conditions characterized by natural and man-made, natural reality of the current scenario of the Neighborhood. / Com o processo de expansão urbana incitado pelo crescimento populacional e desenvolvimento das atividades produtivas e comerciais, entre outros fatores, trouxeram diversos problemas às cidades e às suas populações. Como consequência de um planejamento inadequado de ordenamento territorial, essa expansão produziu um ambiente urbano degradado, com grande influência sobre a qualidade de vida da população, tendo como principais condicionantes dessa ocupação desordenada determinantes demográficos e socioeconômicos. Neste sentido, estudamos a estrutura urbana de uma área de ocupação desordenada na Zona Leste da Cidade de Manaus. As áreas selecionadas foram as comunidades Jorge Teixeira 3ª etapa, Bairro Novo, Arthur Virgílio Filho e João Paulo, integrantes da Unidade de Estrutura Urbana UES (bairro) Jorge Teixeira, conforme Plano Diretor Ambiental Urbano de 2008 da cidade de Manaus. Para a análise e execução da pesquisa, o gerenciamento e tabulação dos dados para manipulação das informações cadastrais e dos atributos espaciais, utilizou-se a padronização dos arquivos shapefile (.shp), os softwares utilizados foram o ArcGis 9.3 e Spring 4.1, ferramentas SIG, utilizou-se o mapa digital da área urbana do Município de Manaus, gerreferenciado em sistemas de projeção geográfica DATUM SAD 69, e imagens do satélite Quickbird 2008 e aerofotogramétrica de 2010. As comunidades do estudo foram visitadas in loco nos segundo semestre do ano de 2007. Os resultados mostram características semelhantes uma para com as outras devido a falta de ordenamento e planejamento para estruturação e edificação de residências, comércios, ruas, sistemas de abastecimento de água, sistemas de rede coletora de esgoto sanitário e industrial, coleta de lixo. Os lotes das quatro comunidades do estudo não obedecem às diretrizes de recuo e afastamentos dos eixos laterais das ruas, distância entre os lotes vizinhos, área máxima para edificação, área para permeabilização, e por conseqüência, área das quadras e lotes destinados para diferentes atividades urbanas, comércios e até mesmo industriais, desobedecendo ao Plano Diretor Ambiental e Urbano de Manaus. Conclui-se que nas comunidades estudadas, pelo seu posicionamento geográfico e estratégico, apresentam situações ambientais caracterizadas por condicionantes naturais e antrópicos, singulares à realidade do cenário atual do Bairro.
167

"Cardiotocografia estimulada em gestações de baixo risco: estudo comparativo da resposta cardíaca fetal à estimulação vibratória e sônica" / Stimulated cardiotocography in low-risk pregnancies: comparative study of fetal cardiac response to vibratory and sonic stimulation

Adriana Cristina de Souza 07 June 2006 (has links)
Trata-se de estudo prospectivo, comparativo da resposta da freqüência cardíaca fetal (FCF) à estimulação vibratória e sônica, quanto à amplitude e duração, em 113 fetos de gestações de baixo risco. A população estudada foi discriminada em quatro grupos: 1) 25 semanas a 28 semanas e seis dias; 2) 29 semanas a 32 semanas e seis dias; 3) 33 semanas a 36 semanas e seis dias e 4) 37 a 42 semanas. Comparando-se a amplitude e a duração da resposta da FCF na faixa três e na faixa quatro, a resposta à estimulação vibratória foi menor que a sônica. Nas faixas um e dois não houve diferença nas respostas. Conclui-se que a estimulação vibratória promove resposta fetal (FCF) menos intensa com amplitude e duração de resposta menor quando comparada à estimulação sônica em faixa de idade gestacional mais tardia / This prospective study compares the response in terms of fetal heart rate acceleration after vibratory and sonic stimulation, in a sample of 113 fetuses of low-risk pregnancies. The study population was divided into four groups according to gestational age: group 1 - 25 weeks to 28 weeks and 6 days; group 2 - 29 weeks to 32 weeks and 6 days; group 3 - 33 weeks to 36 weeks and 6 days, and group 4 - 37 to 42 weeks. Comparing the amplitude and duration of the cardioacceleratory response between group 3 and 4, the response after vibratory stimulation was lower than sonic. In the groups 1 and 2, the response was similar. The study concludes that vibratory stimulation promotes a less intense response with amplitude and duration lower than sonic stimulation in latter gestational age
168

Avaliação técnica SPME/LC na análise de antidepressivos em amostra de plasma para fins de monitorização terapêutica / Evaluation of SPME/LC technique in the antidepressants analysis in plasma sample for ends of therapeutic monitoring

Bruno José Gonçalves da Silva 20 April 2007 (has links)
As recentes técnicas miniaturizadas de preparo de amostra, microextração em fase sólida (SPME) e in tube SPME, apresentam uma série de vantagens em relação aos métodos clássicos de extração (extração líquido-líquido e extração em fase sólida), tais como: não requer instrumentação analítica sofisticada, utilização de pequenas quantidades de solventes orgânicos, rápido processo operacional, permite automação das análises, a reutilização das fases extratoras, e integra em um único sistema a extração, concentração e introdução da amostra no cromatográfico. Esta dissertação tem como objetivo a padronização, validação e comparação dos métodos SPME/LC-UV com dessorção off line e in tube SPME/LC-UV, para a análise dos antidepressivos da nova geração (mirtazapina, citalopram, paroxetina, duloxetina, fluoxetina e sertralina) em amostras de plasma para fins de monitorização terapêutica. As variáveis: fase extratora, pH da matriz, tempo e temperatura de extração e de dessorção e força iônica apresentaram grande influência na eficiência do processo SPME. O método SPME/LC-UV padronizado, apresentou limite de quantificação (LQ) de 25 a 50 ng mL-1, ampla faixa de linearidade (LQ ? 500 ng mL-1, r2 > 0,9970) e precisão inter ensaios com coeficientes de variação menor que 15% para todos os analitos. Apesar das baixas taxas de recuperação obtidas, de 8,1% (citalopram) a 17,1% (mirtazapina), o método SPME/LC-UV apresentou seletividade e sensibilidade analítica adequada. As variáveis: pH da matriz, fluxo e número de ciclos aspirar/dispensar e volume de amostra apresentaram grande influência na eficiência do processo in tube SPME. A etapa de precipitação de proteínas do plasma, anterior ao processo de extração, foi necessária para a eliminação dos compostos endógenos. O método in tube SPME/LC-UV padronizado apresentou seletividade adequada, precisão inter ensaios com coeficiente de variação menor que 10%, LQ de 20 a 50 ng mL-1, linearidade na faixa de concentração do LQ a 500 ng mL-1, com r2 > 0,9983 para todos os analitos e recuperação absoluta de 5,32% (mirtazapina) a 43,5% (sertralina). A técnica in tube SPME, quando comparada à SPME, permitiu a automação das análises, menor exposição do analista às amostras biológicas e solventes orgânicos, menor tempo de análise e menor volume de amostra de plasma. A eficácia dos métodos, SPME/LC-UV e in tube SPME/LC-UV, foi comprovada através das análises de amostras de plasma de pacientes em terapia com os antidepressivos, para fins de monitorização terapêutica. / The recent miniaturized sample techniques preparation, solid phase microextraction (SPME) and in tube SPME, present several advantages when compared with classic extraction methods (liquid-liquid extraction and solid phase extraction), such as: it does not require sophisticated analytical instrumentation, use small organic solvent amounts, fast operational process, automation of the analyses, reuse extraction phases, and incorporates, into a single procedure, sample extraction, concentration and sample introduction. The aim of this work is development, validation and comparison of methods SPME/LC-UV with off line desorption and in tube SPME/LC-UV, for analyses of antidepressants of the new generation (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) in plasma samples for therapeutic drug monitoring. Variables: extraction phase, matrix pH, time and temperature of extraction and desorption and ionic strength showed great influence in SPME process efficiency. The method SPME/LC-UV presented limit of quantification (LOQ) variety from 25 to 50 ng mL-1, wide range the of linearity (LOQ 500 ng mL-1, r2 > 0.9970) and interassays precision with coefficient of variation lower than 15% for all analytes. Although the low recovery, from 8.1% (citalopram) to 17.1% (mirtazapine), the method SPME/LC-UV presented adequate selectivity and analytical sensitivity. Variables: matrix pH, flow and number of aspirate/dispense cycles and sample volume showed great influence in the in tube SPME process efficiency. The protein precipitation of the plasma steps, previous to the extraction process, was necessary for the endogenous compounds elimination. The method in tube SPME/LC showed adequate selectivity, interassays precision with coefficient of variation lower than 10%, LOQ variety from 20 to 50 ng mL-1, linearity in range concentration from LOQ to 500 ng mL-1, with r2 > 0.9983 for all analytes and recovery from 5.32% (mirtazapine) to 43.5% (sertraline). The technique in tube SPME, compared with the SPME, permitted the automation of the analyses, minor exposition of the analyst to the biological samples and organic solvent, shorter analyses time and minor plasma sample volume. The effectiveness methods, SPME/LC-UV and in tube SPME/LC-UV, was proven through the analyses of plasma samples of patients in therapy with antidepressants, for therapeutic drug monitoring.
169

Contribuição de um programa educativo na monitorização da glicemia capilar em pessoas com diabetes mellitus tipo 2 / Contribution of an educational program to capillary glucose monitoring in people with type 2 diabetes mellitus

Rita Cássia Ismail 16 October 2015 (has links)
Trata-se de uma pesquisa de avaliação, realizada por análise de resultados antes e após uma intervenção, cujo objetivo principal foi avaliar a contribuição de um programa educativo na monitorização da glicemia capilar, em pessoas com diabetes mellitus tipo 2. A amostra ficou constituída por 82 pessoas, em seguimento ambulatorial em um hospital de atenção terciária do interior paulista. As intervenções educativas foram desenvolvidas em grupo aberto, por meio da ferramenta \"Mapas de Conversação em Diabetes\", fundamentada nos pressupostos da Teoria Social Cognitiva. O programa educativo se desenvolveu em quatro sessões, com duração média de uma hora e quinze minutos para cada tema, respectivamente: fisiopatologia, controle e complicações da doença, alimentação e atividade física, medicamentos e monitorização da glicemia capilar e da insulina. Além destas sessões, ocorreram dois encontros adicionais para a coleta dos dados, o primeiro antes das intervenções e o segundo, após o seu término. No terceiro encontro, enfatizaram-se os cuidados com a monitorização da glicemia capilar, e foram entregues glicosímetros e insumos para a avaliação da glicemia capilar no domicílio. Para a caracterização da amostra, utilizou-se a estatística descritiva, e para as análises dos dados utilizaram-se os testes de McNemar, para as variáveis categóricas, os Testes de Wilcoxon e o de Correlação de Spearman, mediante nível de significância de 5% (alfa = 0,05). Na caracterização da amostra, destacam-se: 48(58,54%) são do sexo feminino, e os respectivos valores médios da idade são 60,4(DP=8,4) anos; dos anos estudados 4,86(DP=3,86) anos e do diagnóstico da doença 15,3 (DP=8,2) anos. Para o valor de p<0,05, houve diferenças entre os momentos para o conhecimento dos cuidados da monitorização (valores da glicemia de jejum e pós-prandial, descarte dos insumos, sinais/sintomas, prevenção e tratamento da hipoglicemia e da hiperglicemia) e da frequência diária da monitorização da glicemia capilar. O programa educativo contribuiu com a melhora do conhecimento e com a frequência da monitorização da glicemia capilar / This was an evaluative study, developed by means of an analysis of results prior to and after an intervention, whose main objective was to evaluate the contribution of an educational program to capillary glucose monitoring in people with type 2 diabetes mellitus. The sample was made of 82 people, in ambulatory follow-up at a hospital that provides tertiary health care in the interior of the state of São Paulo. The educational interventions were developed in an open group, using the tool \"Diabetes Conversation Maps\", grounded on principles of the Cognitive Social Theory. The educational program was developed in four sessions, with an average duration of one hour and fifteen minutes for each subject, namely: physiopathology; disease control and complications; feeding and physical education; medications, capillary glucose monitoring, and insulin. In addition to these sessions, there were also two meetings for data collection; the first was held prior to intervention, and the second after their completion. At the third meeting, the researchers emphasized the care required for monitoring capillary glucose, and handed the participants with glucometers and materials for assessing capillary glucose at home. Descriptive statistics were used for sample characterization. The McNemar test was used for data analysis, and the Wilcoxon test and Spearman\'s correlation for categorical variables, with significance set at 5% (alpha = 0.05). Sample characteristics that stood out include: 48 (58.54%) participants were women, and respective mean values were 60.4 (SD=8.4) years of age; 4.86 (SD=3.86) years of education, and 15.3 (SD=8.2) years since the disease diagnosis. For the value of p<0.05, there were differences among the moments for learning about the monitoring care (interpretation of results, postprandial glucose levels, glucometer calibration, disposal of the materials, cleansing of the puncture site, knowledge of the terms hypoglycemia and hyperglycemia, conducts towards hypoglycemia and prevention of hypoglycemia and hyperglycemia) and the daily frequency of the capillary glucose monitoring. The educational program contributed to improve the knowledge and frequency of capillary glucose monitoring
170

Estudo clinico do alho fresco em voluntarios sadios : avaliação da agregação plaquetaria in vitro e in vivo e comportamento da pressão arterial atraves da MAPA in vivo

Abib Junior, Eduardo 11 December 2004 (has links)
Orientador: Gilberto de Nucci / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T10:02:10Z (GMT). No. of bitstreams: 1 AbibJunior_Eduardo_D.pdf: 639040 bytes, checksum: e96fa4a810e2980947816b23f3c078a1 (MD5) Previous issue date: 2005 / Resumo: Objetivo: Esta tese tem por objetivos: avaliar a agregação plaquetária e o comportamento da pressão arterial em três momentos (sem alho; alho dose única (3,5 g) e alho dose diária (3,5 g) duas vezes ao dia por 4 dias) em voluntários sadios; Analisar a resposta de agregação plaquetária in vitro adicionando extrato de alho diluído em PRP e por ultimo correlacionar os dados obtidos da analise da agregação com os parâmetros TxB2, GMPc entre in vivo e in vivo. Para Analise em in vivo foram selecionados dezoito (18) voluntários do sexo masculino, entre 18 a 45 anos, saudáveis, para estudo não randomizado, aberto e divididos em tres grupos (Grupo Sem alho; Grupo Com Alho Único e Grupo Alho Diário). Amostras de sangue dos voluntários foram coletadas de acordo com horários pré-estabelecidos. Após execução da agregação plaquetária, Pressão arterial através da MAPA e quantificação dos níveis de TXB2, foram realizadas análises estatisticas. Para analise in vitro foram selecionados 5 voluntários sadios, de ambos os sexos, isentos de qualquer medicação uma semana antes coleta. O sangue foi coletado e o PRP foi separado e adicionado extrato de alho em volume determinado. Após execução da agregação plaquetária e quantificação dos níveis de TXB2, foram tb realizadas análises estatisticas. Tendo estes dados tanto in vivo quanto in vivo procedeu-se a analise comparativa entre eles. Resultados : Na analise in vivo, tanto a agregação plaquetária quanto a inibição da formação de TxB2 não se observou diferença entre os outros grupos independente do agonista utilizado. Na analise in vitro, os resultados sugeriram que o extrato de alho, em quantidades pequenas, inibi a agregação plaquetária Os resultados se confirmaram com o TXB2, pois quantidades de extrato que foram capazes de inibir a agregação plaquetária induzida por todos agonistas, inclusive àquela induzida por AA, não causou diminuição significativa da síntese de TXA2 induzida por AA. Houve variação significativa da PA sistólica e FC com administração diária de alho fresco comparada ao sem alho e alho único. Conclusão: Concluímos que outros mecanismos podem estar envolvidos na inibição da agregação plaquetária que não da inibição da ciclooxigenase plaquetária quando utilizado o extrato de alho. Não há uma inibição da agregação plaquetária através da ação sobre a ciclooxigenase quando observado em voluntários que ingeriram alho fresco. A administração de alho in natura, pequenas quantidades (3,5g de dente de alho = 16 mg alicina/g de alho) pode contribuir para promover alterações no comportamento hemodinâmico como observado através da MAPA em voluntários sadios / Abstract: Objective: This thesis has as objectives: to evaluate the platelet aggregation and the behavior of blood pressure in three moments (control; garlic single dose (3,5 g) and garlic daily dose (3,5 g) twice a day for 4 days) in healthy volunteers; To analyze the in vitro platelet aggregation answer adding garlic extract diluted in PRP and the last to correlate the obtained data from the aggregation analysis with the TxB2, GMPc parameters between in vivo and in vivo. For the in vivo Analysis eighteen (18) healthy volunteers of the masculine gender between 18 and 45 years old were selected, for an open, non-randomized study and divided into three groups (Control; Group With Single Garlic and Group Daily Garlic). Samples of the volunteers' blood were collected according to the pre-established schedules. After execution of the platelet aggregation, blood Pressure through AMBP and quantification of TXB2 levels , statistical analyses were accomplished. For in vitro analysis 5 healthy volunteers of both genders were selected, free of any medication one week before collection. The blood was collected and the PRP was separated and added garlic extract in determined volume. After execution of the platelet aggregation and quantification of TXB2 levels, statistical analyses were also accomplished. Having these in vivo data as well in in vivo the comparative analysis between them was preceeded. Results: There was significant variation of the systolic BP and HR with daily administration of fresh garlic compared to control and single garlic. Regarding the platelet aggregation it was observed difference between the daily garlic group and the other two groups (P <0.005) when used agonist arachidonic acid. In the in vitro analysis, the results suggested that the garlic extract, in small amounts, can inhibit the platelet aggregation without affecting in a significant way the activity of ciclooxygenase. The results were confirmed with the TXB2, for amounts of extract that were capable to inhibit the platelet aggregation induced by all agonists, including that one induced by AA, didn't cause significant decrease of TXA2 synthesis induced by AA. Conclusion: We concluded that other mechanisms can be involved in the inhibition of the platelet aggregation other than the inhibition of the platelet ciclooxygenase when used the garlic extract. There is not an inhibition of the platelet aggregation through the action on the ciclooxygenase when observed in volunteers that ingested fresh garlic. The administration of garlic in natura, small quantities (3,5g garlic glove = 16 mg allicim/g garlic) can contribute to promote alterations in the hemodynamic behavior as observed through the AMBP in healthy volunteers / Doutorado / Clinica Medica / Doutor em Clínica Médica

Page generated in 0.0915 seconds