• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 18
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 327
  • 168
  • 87
  • 83
  • 82
  • 66
  • 63
  • 58
  • 57
  • 41
  • 39
  • 33
  • 30
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Avaliação dos indicadores biológicos de exposição aos metais em trabalhadores de fundições / Evaluation of biological indicators of exposure to metals in foundry workers

Santos, Claudia Regina dos 07 December 2004 (has links)
A produção de metais sanitários é um setor em constante fase de crescimento no país. O processo industrial envolve etapas como a evaporação, condensação e oxidação dos metais no ar que levam a formação de fumos metálicos em vários tipos de indústria, inclusive em fundições. A exposição do trabalhador ao ambiente contaminado pode levar ao aparecimento de alterações bioquímicas e, em algumas circunstâncias, de doenças profissionais. No setor de metais sanitários, são utilizadas ligas metálicas de latão, onde predomina o zinco e o cobre, sendo o chumbo, cádmio, manganês e níquel, metais que aparecem sob a forma de impurezas. Desses metais, apenas o chumbo sanguíneo (Pb-S) e o cádmio urinário (Cd-U) são regulamentados no Brasil, de acordo com a NR-7 do Ministério do Trabalho, como indicadores biológicos de exposição. No presente estudo, foram otimizados e validados métodos para a determinação de Pb-S, Cd-U, Mn-U e Ni-U por espectrometria de absorção atômica acoplado a forno de grafite. Posteriormente foram avaliados 273 indivíduos do sexo masculino (178 do grupo exposto e 95 do grupo controle) que trabalhavam em 8 fundições de metais sanitários de Loanda-PR. Os níveis de Pb-S apresentaram-se elevados, considerando o limite internacional. Os metais avaliados na urina Cd-U, Mn-U e Ni-U apresentaram concentrações relativamente baixas, sendo considerado o chumbo como o principal problema, relacionado aos fumos metálicos. Foram propostas medidas corretivas nos ambientes de trabalho e os níveis dos quatro metais em questão foram reavaliados em dois períodos diferentes (antes e após as modificações), apresentando no segundo momento reduções estatisticamente significativas. As médias observadas nos dois períodos foram de 42,74&#181;g/dL e 26,54&#181;g/dL para o Pb-S; 0,269 e 0,015&#181;g/g de creatinina para o Cd-U; 1,94 e 0,39&#181;g/g de creatinina para o Mn-U e 1,82 e 0,68&#181;g/g de creatinina para o Ni-U, com níveis de significância (p) < 0,05, evidenciando assim a importância da adequação do ambiente de trabalho na garantia de exposições seguras para o trabalhador. / The sanitary metal production is a sector in constant development in Brazil. This industrial process involves stages such as evaporation, condensation and oxidation of metals, therefore allowing the formation of metallic fumes in some types of industry, and also in foundries. The contaminated environment can induce, in the workers, biochemical alterations and, in some circumstances, occupational diseases. In the sanitary metal sector, alloys are used in which predominate the metals zinc and copper, being lead, cadmium, manganese and nickel, metals that can be found in the form of impurities. According to Brazilian legislation\'s (Ministry of Work) only lead in blood and cadmium in urine are regulated as biological monitoring of exposure. In the present study, methods based on graphite furnace atomic absorption spectrometry and zeeman background correction were validated for quantification of Pb-B, Cd-U, Mn-U and Ni-U, and 273 male individuais (178 exposed group and 95 non exposed - control group), working in 8 sanitary metal foundries, in Loanda, Paraná, a state located in the south of Brazil, were evaluated. The levels of Pb-B were higher than the international permissible limit. Relatively low concentrations were found for the other evaluated metals: Cd-U, Mn-U and Ni-U, thus lead can be considered, in this case, the main problem, associated with metallic fumes. Corrective measures in the work environment were proposed and implemented, thus the four metais were evaluated in two distinct situations (biological determinations were done before and after the modifications). The results of the second evaluation showed reductions those were statistically significant. The means obtained in the two determinations were 42,74&#181;g/dL and 26,54&#181;g/dL for Pb-B; 0,269 and 0,015&#181;g/g creatinine for Cd-U; 1,94 and 0,39&#181;g/g creatinine for Mn-U and 1,82 and 0,68&#181;g/g creatinine for Ni-U, with leveis of significance (p) < 0,05, thus evidencing the importance of the adequacy of the work environment in the guarantee of safe exposures for the workers.
182

Avaliação da variação de pressão de pulso (VPP) frente a diferentes concentrações inaladas de isoflurano, desflurano e sevoflurano: modelo experimental em suínos / Evaluation of pulse pressure variation (PPV) using different concentrations of isoflurane, desflurane and sevoflurane: experimental model in pigs

Alexandre Hideaki Oshiro 30 January 2013 (has links)
Introdução: Os anestésicos inalatórios empregados atualmente na prática clinica (isoflurano, sevoflurano e desflurano) possuem propriedades farmacocinéticas que favorecem rápida recuperação da anestesia, porém seu uso pode causar instabilidade hemodinâmica dose-dependente, relacionado à depressão direta da contratilidade miocárdica ou à hipovolemia relativa, derivado de um sequestro de sangue devido à vasodilatação do leito vascular periférico. Este estudo visa avaliar o comportamento da VPP durante a anestesia inalatória. Para tanto se utilizou três diferentes agentes inalatórios (isoflurano, sevoflurano e desflurano) em diferentes concentrações inaladas. Métodos: Foram utilizados 25 suínos divididos aleatoriamente em três grupos. Os animais foram submetidos à anestesia com o anestésico do respectivo grupo. Imediatamente após a determinação da CAM individual do agente inalatório em cada animal, ocorreu a primeira coleta de dados. O animal foi, então, exposto a diferentes níveis de CAM (1,0 CAM; 1,25 CAM) seguido por uma exposição decrescente de CAM (1,0 CAM); provocou-se então uma hemorragia correspondente a 30% da volemia e exposição a dois níveis de CAM (1,0 e 1,25), com 20 minutos em cada exposição. Ao final de cada período os valores ecocardiográficos e do VPP foram mensurados. A análise estatística foi realizada através de provas paramétricas empregando-se o método de comparações múltiplas para análise de variância com medidas repetidas (ANOVA). O grau de significância foi de 5% (p < 0,05). Resultados: Há aumento na variação de pressão de pulso com incremento de 25% na CAM dos anestésicos inalatórios (de 8±1 para 11±3% no grupo DESF, de 7±2 para 9±2 no grupo SEVO e de 9±4 para 10±3% no grupo ISO) sem diferença estatística entre os anestésicos. Apesar deste aumento na CAM e significativa hipotensão e queda no débito cardíaco, o aumento na VPP não torna o paciente responsivo a infusão de fluidos (o VPP permaneceu abaixo de 13%). Há pequena queda na PAM quando se eleva a CAM dos anestésicos em 25%, porém só há queda estatisticamente significativa no grupo DESF (de 84±7 para 68±12 mmHg). Não foram observadas alterações importantes em relação à contratilidade miocárdica. Conclusão: Observou-se que a VPP não é influenciada como o uso dos diferentes anestésicos inalatórios e apesar dos efeitos cardiovasculares esperados destes agentes, mantem-se a capacidade de demonstrar alterações de pré-carga mesmo em concentrações correspondentes a 1,25 CAM / Background: Inhalant anesthetics, such as isoflurane, sevoflurane and desflurane are widely used in daily clinical practice due to its pharmacological properties allowing a rapid recovery from anesthesia. Nevertheless, its use can lead to dose-dependent hemodynamic instability related to direct depression in myocardial contractility or to a relative hypovolemia caused by vasodilation of peripheral capillary bed. This study aims to evaluate the behavior of PPV during inhalant anesthesia. For this, three different anesthetics were used (isoflurane, sevoflurane and desflurane) with different inhaled concentrations. Methods: 25 young pigs were randomly assigned into three groups. Animals were anesthetized with its correspondent agent according to its group. After individual determination of minimal alveolar concentration (MAC), first data collection occurred. Pigs were then exposed to different MAC (1MAC and 1,25 MAC) followed by a decrease in MAC (1 MAC). At this point a 30% of estimated volemia hemorrhage was caused and pigs were exposed to a period of 1 MAC and after that 1,25 MAC. Each period lasted 20 minutes. At the end of each period, hemodynamic parameters and echocardiography were collected. Data were submitted to analysis of variance for repeated measures (ANOVA). P<0,05 was considered statistically significant. Results: There was an increase in PPV when with 1,25 MAC of all anesthetics. (from 8±1 to 11±3% in group DESF, from 7±2 to 9±2 in group SEVO and from 9±4 to 10±3% in group ISO), but without statistical difference among groups. Although there was an increase in PPV, followed by hypotension and drop in cardiac index, patients werent fluid responsive with a 25% increase in MAC, since PPV was lower than 13%. The decrease in blood pressure followed by 1,25MAC was only significant in DESF group (from 84±7 to 68±12 mmHg). No important alterations related to myocardial contractility were observed. Conclusion: PPV is not influenced by the use of different inhalant anesthetics and although there are cardiovascular effects of these agents which are expected, and were able to demonstrate alterations in preload even in concentration of 1,25 MAC
183

Magnitude e duração da resposta hipotensora em hipertensos: efeitos do exercício físico contínuo e intervalado / Magnitude and duration of hypotensive response in hypertensive patients: effects of continuous and interval physical exercise

Carvalho, Raphael Santos Teodoro de 28 August 2014 (has links)
Estudo de abordagem quantitativa e delineamento quase-experimental com o objetivo de comparar os efeitos dos exercícios dinâmicos contínuo e intervalado sobre a magnitude e duração da resposta hipotensora em hipertensos. A amostra foi composta por 20 idosos hipertensos de um município do interior paulista. As variáveis estudadas foram agrupadas nas categorias: sociodemográficas, antropométricas e hemodinâmicas. Cada participante foi submetido duas sessões de exercício físico, com intervalo de uma semana entre os treinos. As sessões de exercício contínuo foram realizadas a intensidade do limiar anaeróbio. Nas sessões de exercício intervalado, os indivíduos trabalharam no limiar de compensação respiratória por 4 minutos durante a fase ativa; na fase de recuperação, trabalharam a 40% do consumo máximo de oxigênio por 2 minutos. O tempo total de cada sessão foi de 42 minutos. Para obtenção dos dados hemodinâmicos, os participantes realizaram três exames de Monitorização Ambulatorial da Pressão Arterial (MAPA), com duração de 24 horas: MAPA controle, MAPA após exercício contínuo e MAPA após exercício intervalado. As análises descritivas, com cálculo de frequências absolutas e porcentagens e descrição das médias, desvio padrão e medianas, foram realizadas por meio do pacote estatístico SPSS, versão 15.0. A descrição das diferenças proporcionais entre os grupos foi realizada primordialmente por meio de aplicação do teste estatístico não paramétrico de Wilcoxon. Em todas as análises, foi adotado o nível de significância estatística de 5% (p&lt;0,05).Quando comparamos os resultados da MAPA realizada após o exercício contínuo aos valores derivados da MAPA controle, encontramos diferença estatisticamente significante para as variáveis Pressão Arterial Sistólica (PAS) vigília (p&lt;0,001), PAS sono (p&lt;0,001), Pressão Arterial Diastólica (PAD) vigília (p&lt;0,001), PAD sono (p&lt;0,001), Pressão Arterial Média (PAM) vigília (p&lt;0,001), PAD sono (p&lt;0,001), Frequência cardíaca (FC) sono (p&lt;0,03) e Duplo Produto (DP) vigília (p&lt;0,002) e sono (p&lt;0,001), sendo que todos os índices mostraram redução após a prática do exercício contínuo. À comparação dos resultados da MAPA após exercício intervalado aos resultados da MAPA controle, constatamos que, após a prática de exercício, houve redução nos valores de PAS vigília (p&lt;0,001), PAS sono (p&lt;0,001), PAD vigília (p&lt;0,001), PAD sono (p&lt;0,001), PAM vigília (p&lt;0,001), PAM sono (p&lt;0,001) e DP vigília (p&lt;0,001) e DP sono (p&lt;0,001). Na comparação do exercício contínuo ao intervalado, encontramos diferença estatisticamente significante para as variáveis PAS vigília (p&lt;0,001) e sono (p&lt;0,01), PAD vigília (p&lt;0,001), PAM vigília (p&lt;0,001), PAM sono (p&lt;0,01), DP vigília (p&lt;0,01) e DP sono (p&lt;0,001), que se mostraram mais reduzidas após a prática do exercício intervalado. Concluímos que a prática de exercício físico contínuo e intervalado promove a hipotensão pós-exercício (HPE) ao longo das 20 horas subsequentes à atividade. O exercício intervalado gera maior magnitude de HPE e menor sobrecarga cardiovascular em comparação ao exercício contínuo. / Quantitative study with a quasi-experimental design to compare the effect of continuous and interval dynamic exercises on the magnitude and length of the hypotensive response in hypertensive patients. The sample consisted of 20 hypertensive elderly patients from a city in the interior of the State of São Paulo, Brazil. The study variables were grouped in the following categories: sociodemographic, anthropometric and hemodynamic. Each participant was submitted to two physical exercise sessions with a one-week interval between the training. The continuous exercise sessions were held at the intensity level of the anaerobic threshold. In the interval exercise sessions, the participants exercised at the respiratory compensation threshold for four minutes during the active phase; in the recovery phase, they worked at 40% of the maximum oxygen consumption for two minutes. The total length of each session was 42 minutes. To obtain the hemodynamic data, the participants undertook three outpatient Ambulatory Blood Pressure Monitoring (ABPM) tests, which took 24 hours: control ABPM, ABPM after continuous exercise and ABPM after interval exercise. For the descriptive analyses, including the calculation of absolute frequencies and percentages and the description of means, standard deviations and medians, the statistical software SPSS version 15.0 was used. The description of the proportional differences between the groups was mainly based on the application of Wilcoxon\'s non-parametric statistical test. In all analyses, statistical significance was set at 5% (p&lt;0,05).When comparing the ABPM results after continuous exercise with the results of the control ABPM, a statistically significant difference was found for the variables Systolic Blood Pressure (SBP) wake (p&lt;0.001), SBP sleep (p&lt;0.001), Diastolic Blood Pressure (DBP) wake (p&lt;0.001), DBP sleep (p&lt;0.001), Mean Blood Pressure (MBP) wake (p&lt;0.001), MBP sleep (p&lt;0.001), Heart frequency (HF) sleep (p&lt;0.03) and Double Product (DP) wake (p&lt;0.002) and sleep (p&lt;0.001). All indices showed a drop after continuous exercise. In the comparison between the ABPM results after interval exercise with the control ABPM results, after the exercise, the following levels dropped: SBP wake (p&lt;0.001), SBP sleep¬ (p&lt;0.001), DBP wake (p&lt;0.001), DBP sleep (p&lt;0.001), MBP wake (p&lt;0.001), MBP sleep (p&lt;0.001) and DP wake (p&lt;0.001) and DP sleep (p&lt;0.001). In the comparison between the continuous and interval exercises, a statistically significant difference was found for the variables SBP wake (p&lt;0.001) and sleep (p&lt;0.01), DBP wake (p&lt;0.001), MBP wake (p&lt;0.001), MBP sleep (p&lt;0.01), DP wake (p&lt;0.01) and DP sleep (p&lt;0.001), which were lower after the interval exercise sessions. In conclusion, the practice of continuous and interval physical exercise promotes post-exercise hypotension (PEH) during the 20 hours after the exercise. Interval exercises lead to a larger HPE and less cardiovascular burden in comparison with continuous exercise.
184

Papel do monitoramento remoto contínuo na detecção e no manejo terapêutico da fibrilação atrial em idosos com marca-passo definitivo / Role of continuous remote monitoring to detect and in the management of atrial fibrillation in elderly pacemaker patients

Lima, Carlos Eduardo Batista de 24 April 2012 (has links)
Introdução: a fibrilação atrial (FA) é a arritmia mais frequente na prática clínica estando associada à elevada taxa de morbidade e mortalidade. O risco de acidente vascular cerebral (AVC) apresenta-se aumentado em pacientes com FA e há evidência de aumento progressivo do risco com o avançar da idade. A detecção precoce da FA pode permitir a antecipação terapêutica e consequente redução de morbimortalidade. Vários recursos diagnósticos têm sidos utilizados com essa finalidade incluindo o marca-passo cardíaco definitivo (MPD) que permite armazenar registros de elevada frequência no canal atrial. Sistemas atuais de monitoramento remoto contínuo (MRC) do portador de MPD permitem a identificação e o envio diário à distância destes eventos armazenados pelo dispositivo. Objetivo: definir o papel do MRC na detecção e no manejo da FA em idosos portadores de MPD. Método: foi um estudo prospectivo e randomizado com seleção consecutiva de 300 idosos (60 anos ou mais) entre março/2007 e janeiro/2010, em ritmo sinusal e com indicação para implante ou troca de MPD. Os pacientes (P) foram randomizados para grupo de intervenção (GI) em monitoramento remoto contínuo (n=150) e grupo controle (GC) em seguimento convencional (n=150) com consultas agendadas para 30, 90, 180 dias e posteriormente a cada seis meses até dois anos de seguimento. No GI foram realizadas consultas extras motivadas por alertas automáticos de FA com duração mínima de 2,5 horas enviados pelo sistema de MRC. Resultados: o tempo de seguimento médio foi de 435 dias. Não houve diferença entre os grupos (GI x GC) em relação à idade (75,5 x 74,3 anos, p=0,44), sexo (feminino 54,7% x 57,4%, p=0,46), indicação do MPD (BAV 89,7% x 88,7%; p=0,84) e eventos clínicos (incidência de FA 25,3% x 19,3%, p=0,42; AVC 1,4% x 0%, p=0,44 e óbitos 8,6% x 5,3%, p=0,16). Houve mais documentação eletrocardiográfica da FA no GI (10%) em comparação ao GC (4%), p=0,027 e o MPD detectou corretamente a FA em 95,2% desses casos. O tempo para a primeira recorrência da FA foi de 79 x 128 dias; p=0,005. O número de dias em FA foi menor no GI (16 dias; IConf 95%: 8,89 a 23,18) em relação ao GC (51,9 dias; IConf 95%: 21,89 a 81,93), p=0,028. Baseados no escore CHADS2 houve mais pacientes com indicação para terapia antitrombótica no GI (p=0,008). Foram realizadas 55 consultas extras motivadas pelo sistema de MRC com necessidade de mudança terapêutica em 81% dos casos (36% antitrombóticos, 20% antiarrítmicos, 13% reprogramação MPD e 12% cardioversão). Conclusões: o MRC proporcionou menor tempo para a detecção da FA reduzindo o número de dias em arritmia devido à antecipação da terapêutica. Houve mais pacientes com documentação eletrocardiográfica da FA e submetidos à terapia antitrombótica no GI. Os alertas automáticos do sistema de MRC apresentaram importância clínica na maioria das consultas extras havendo necessidade de modificações na terapia antiarrítmica e antitrombótica, assim como na reprogramação do MPD. Os resultados deste estudo destacam o MRC como ferramenta auxiliar no manejo da FA em idosos portadores de MPD / Introduction: atrial fibrillation (AF) is the most common arrhythmia in clinical practice and it is related to high prevalence of morbidity and mortality. The annual risk of stroke is increased in AF patients especially with advancing age. Early AF detection should anticipate the management of AF which can reduces morbidity and mortality. Atrial high rate episodes device detected is a good diagnostic tool in PM carriers and these events can be sent daily to the doctor by continuous remote monitoring (CRM) systems. The aim of this study was to determine the role of CRM to detect and in the management of AF in elderly pacemaker patients. Method: It was a randomized and prospective study. Between March/2007 and January/2010 we selected 300 consecutive patients with an indication to atrioventricular pacemaker implantation or generator change. There were included patients in sinus rhythm with 60 years old or more. They were randomized in remote group (RG=150) and control (CG=150). Follow-up (FU) was scheduled in 30, 90 and 180 days and after, 6/6 months until two years. Patients in RG had extra appointment if automatic AF alerts (minimum AF burden of 2.5 hours) were sent by CRM. Results: FU mean time was 435 days. There were no difference between studied groups (RG vs. CG) in age (75.5 vs. 74.3 years, P=0.44); gender (female 54.7% vs. 57.4%, P=0.46); pacemaker indication due to sick sinus syndrome 10.3% vs. 11.3% and AV block 89.7% vs. 88.7%, P=0.84; AF incidence 25.3% vs. 19.3%, P=0.42; stroke 1.4% vs. 0%, P=0.44 and death 8.6% vs. 5.3%, P=0.16. AF was documented by electrocardiogram in 21 patients (RG=10% vs. CG=4%, P=0.027) and the pacemakers detected AF correctly in 95,2%. Median time to first AF recurrence was 79 vs. 128 days, P=0.005. The mean AF days was 16.0 (IC95%; 8.89 to 23.18) vs. 51.91 (IC95%; 21.89 to 81.93); P=0.028. According CHADS2 score, there were more patients with an antithrombotic therapy indication in RG (P=0.008). In 55 extra appointments, there was a therapy change in 81% of them (36% antithrombotic therapy, 20% arrhythmic therapy, 13% pacemaker programming and 12% electrical cardioversion). Conclusion: CRM allowed earlier AF detection which reduced AF days by anticipated therapy. In RG, the time to detection of first AF recurrence was lower than in the conventional approach. There were more AF documented by EKG and more patients with an indication to antithrombotic therapy in RG. Most of extra appointment needed a therapy change with regard to antithrombotic or antiarrhythmic therapy and device programming. The results of this study point out the CRM like a good auxiliary tool in the management of AF in elderly pacemaker patients
185

Anormalidades da homeostase pressórica identificadas através da monitorização ambulatorial da pressão arterial : estudo transversal em adultos com diferentes graus de tolerância à glicose

Piccoli, Vanessa January 2016 (has links)
O pré-diabetes (PDM), da mesma forma que o diabetes mellitus (DM), associa-se com complicações micro e macrovasculares. Existem evidências de que existem anormalidades da homestoase da pressão arterial em indivíduos com PDM. Através da monitorização ambulatorial da pressão arterial (MAPA) é possível identificar o padrão de homeostase pressórica de indivíduos com diferentes graus de tolerância à glicose. Evidências demonstram que as medidas de pressão arterial (PA) obtidas por MAPA apresentam melhor associação com lesões de órgãos alvo se comparadas a medidas obtidas em consultório. Medidas de PA obtidas através de MAPA demonstram melhor correlação com complicações crônicas microvasculares do DM. Entretanto, dispõe-se de poucos dados na literatura sobre o comportamento da pressão arterial de 24 horas em indivíduos com PDM. Este trabalho é inicialmente constituído de uma revisão direcionada sobre homeostase pressórica em indivíduos com diferentes graus de tolerância à glicose seguido de um artigo original a respeito do tema. O artigo se trata de um estudo transversal que avaliou o padrão de homeostase pressórica de 24 horas em 138 indivíduos com diferentes graus de tolerância à glicose. O estudo demonstrou que através da MAPA é possível observar uma elevação dos níveis de pressão arterial ao longo de 24 horas de acordo com a piora da tolerância à glicose. / As diabetes mellitus (DM), prediabetes is associated with microvascular and macrovascular complications. There is evidence of presence of abnormalities in blood pressure (BP) homeostasis in individuals with prediabetes (PDM). Ambulatory blood pressure monitoring (ABPM) enables to identify the pattern of BP homeostasis in individuals with different degrees of glucose tolerance. Evidences have shown that BP measurements obtained by ABPM have a better association with target organ damage compared to measurements obtained in the office. Studies have also shown better correlation of BP measurements obtained by ABPM with microvascular chronic complications of DM. However, there are few data in literature about the behavior of 24 hours BP in subjects with prediabetes. This study consists of a review focused on BP homeostasis in subjects with different degrees of glucose tolerance and an original article about this issue. This is a cross-sectional study that evaluated how BP homeostasis behaves along 24 hours in 138 subjects with different degrees of glucose tolerance. The study demonstrated that through the ABPM is possible to observe an increase in blood pressure levels over 24 hours according to a worsening of glucose tolerance.
186

Frequência das contrações uterinas em gestações gemelares assintomáticas em uso de progesterona natural: estudo randomizado, duplo cego, placebo controlado / Uterine contractions frequency in asymptomatic twin pregnancies under natural progesterone use: a randomized, double-blind, placebo-controlled study

Lilia Araujo Moura Lima de Oliveira 10 June 2015 (has links)
Objetivos: O presente estudo teve como objetivo comparar a frequência das contrações uterinas em gestações gemelares em uso da progesterona natural e de placebo. Método: Estudo randomizado, duplo-cego, placebo controlado, realizado no período de 01 de junho de 2007 a 31 de outubro de 2013. Participaram do estudo 341 gestantes, com 170 randomizadas no grupo progesterona e 171 no grupo placebo. Todas as gestantes realizaram exame de tocografia no período de 24 a 34 semanas e 6 dias, com duração de trinta minutos, a cada três semanas. A contração uterina foi definida como uma elevação da linha de base com amplitude acima de 5 mm e duração mínima de trinta segundos. Na comparação da frequência das contrações uterinas entre os grupos, nas diferentes idades gestacionais, utilizou-se o teste t de Student. O modelo de análise GEE - modelo generalizado de equações de estimação - foi utilizado na comparação, entre os grupos, da frequência das contrações uterinas em relação à idade gestacional no parto, e também na avaliação da interação da frequência das contrações uterinas com a medida do colo uterino e a corionicidade. Resultados: As características epidemiológicas e gerais das gestantes foram semelhantes nos dois grupos. A frequência média das contrações uterinas diferiu entre os grupos apenas na 34ª semana (P = 0,005), com frequência maior de contrações no grupo progesterona (4,81±3,24) em relação ao grupo placebo (2,73 ± 2,06). Não houve diferença significativa na comparação da frequência média das contrações uterinas e a idade gestacional no parto (< 28 sem, < 32 sem, < 34 sem e < 37 semanas) entre os grupos. Não foi observada interação da frequência das contrações uterinas com a medida do colo uterino ou com a corionicidade da gestação, em relação aos grupos progesterona ou placebo. Conclusão: O uso da progesterona natural não interfere na frequência das contrações uterinas nas gestações gemelares abaixo de 34 semanas gestacionais / Objectives: The aim of this study was to comparate uterine contraction frequency in twin pregnancies in use of natural progesterone and placebo. Methods: Randomized, double-blind, placebo-controlled study, conducted between June 1, 2007 to October 31, 2013. The study included 341 twin pregnancies, with 170 randomized in the progesterone group and 171 in the placebo group. All pregnancies had uterine contraction registration by tocodinamometry every three weeks, during 30 minutes between 24 to 34 weeks and 6 days. Uterine contraction was defined as an amplitude greater than 5 mm, from baseline registration, and a duration longer than 30 seconds. Comparison of contraction frequency between the groups at different gestational ages was examined using the parametric student t test. The model GEE - generalized estimating equation model - was used in the comparison, between the groups, the uterine contraction frequency according gestational age at delivery, and also for evaluating the interaction of the frequency contractions with cervical length and chorionicity. Results: Epidemiological and general characteristics of the pregnant woman were similar in both groups. At the 34 weeks, was only gestational age that presented difference (P = 0.005) in the mean uterine contraction frequency between progesterone (4.81 ± 3.24) and placebo (2.73 ± 2.06) groups. No difference in the mean uterine contraction frequency was observed between progesterone and placebo groups in relation to gestational age at delivery. Cervical length measurement and chorionicity did not influence the uterine contraction frequency according to progesterone or placebo. Conclusion: The use of natural progesterone in twin pregnancies does not affect the uterine contraction frequency before 34 weeks gestation
187

Comparação das medidas de pressão arterial no consultório, no domicílio e pela monitorização ambulatorial da pressão arterial (MAPA) em crianças com hipertensão arterial / Comparison of blood pressure measurement in the office, at home and ambulatory blood pressure (ABP) in children with arterial hypertension

Erika Arai Furusawa 03 October 2008 (has links)
O diagnóstico e acompanhamento da hipertensão arterial (HA) no paciente pediátrico dependem da acurácia e da representatividade da medida da pressão arterial (PA). A monitorização ambulatorial da pressão arterial (MAPA), apesar de suas vantagens em relação à medida casual, apresenta custo elevado e pode trazer desconforto ao paciente. A medida residencial da pressão arterial (MRPA), apesar de pouco estudada na criança, apresenta-se como um alternativo potencial à MAPA. Os objetivos deste estudo foram comparar as medidas da PA aferidas no consultório, na MRPA, na Liga de Hipertensão e pela MAPA avaliando o efeito do ambiente/observador e determinando a freqüência de valores compatíveis com HA nessas 4 situações. Este estudo foi transversal,prospectivo e foram incluídos pacientes com HA e PA controlada ou não no consultório. Foram analisadas as médias das pressões arteriais sistólicas e diastólicas. A MRPA foi realizada com aparelho OMRON HEM 705 CP por 14 dias, em dois períodos (manhã ou tarde e noite). Na véspera do início da MRPA, o paciente compareceu à Liga de Hipertensão do HC-FMUSP para colocação do equipamento da MAPA (SPACELABS 90207). Foram analisados os dados de 40 pacientes (14 meninas e 26 meninos), idade média 12,1±3,6 anos. Não houve diferença estatística entre as médias das pressões sistólicas (ANOVA p=0,3100) e diastólicas (ANOVA p=0,7700) no consultório com as médias diurnas da MRPA e nem com as médias sistólicas (ANOVA p=0,8240) e diastólicas(ANOVA p=0,1530) do período noturno da MRPA. As médias das pressões sistólicas e diastólicas da Liga e da MAPA foram maiores do que as médias do consultório e da MRPA (p<0,001), porém não houve diferença estatística entre as médias sistólicas e diastólicas da Liga com a MAPA (p=0,077) e (p=0,962) respectivamente. As médias das pressões diastólicas da MRPA foram menores do que as médias do consultório (p=0,001). Em relação à freqüência de pacientes com PA não controlada, esta foi maior na Liga de Hipertensão (Mc Nemar p<0,005), enquanto as comparações entre consultório MRPA diurna, consultório-MAPA vigília, MRPA diurna- MAPA vigília não foram significantes (Mc Nemar p>0,05). Na MAPA sono, os pacientes apresentaram maior freqüência de PA controlada do que na MRPA noturna. Dez pacientes apresentaram PA não controlada no consultório, a MAPA confirmou o diagnóstico em 7/10 (17,5%) pacientes, enquanto 5/10 (12,5%) confirmaram pela MRPA. Nesse grupo, a hipertensão do avental branco ocorreu em 3/10 (7,5%) pacientes diagnosticados pela MAPA e em 5/10 (12,5%) diagnosticados pela MRPA.Trinta pacientes apresentaram valores de PA controlados no consultório, destes 24/30 (60%) pacientes confirmaram o diagnóstico pela MAPA e 26/30 (65%) pela MRPA. A hipertensão mascarada ocorreu em 6/30 (15%) pacientes diagnosticados pela MAPA e em 4/30 (10%) diagnosticados pela MRPA. Nesse estudo demonstrou-se concordância entre MAPA e MRPA (teste de Mc Nemar p<0,01) com boa reprodutibilidade à avaliação do índice Kappa (0,557). / The diagnosis and monitoring of hypertension in pediatric patients depend on the accuracy and reproducibility of blood pressure (BP) measurement. Ambulatory blood pressure monitoring (ABPM), despite its advantages over office BP, is costly and can cause discomfort to the patient. The blood pressure measured at home (HBP), although poorly studied in children, represents a potential alternative to ABPM. The objectives of this study were to compare BP measurement in four clinical conditions: office BP , casual BP measured at Liga de Hipertensão, HBP and ABPM, evaluate the effect of environment / observer and to determine the frequency of BP values compatible with the diagnosis of hypertension. This study was cross-sectional and prospective and included patients with arterial hypertension with/without properly controlled BP in the office. The means of systolic and diastolic BP were analyzed in the 4 clinical conditions. HBP was measured for 14 days using a validated fully automatic Omron HEM 705 CP device. ABPM was measured with SpaceLabs 90207 non-invasive portable oscilometric device. We analyzed data from 40 patients (14 girls and 26 boys), mean age 12.1 ± 3.6 (SD) years. There was no difference between systolic (ANOVA p = 0.3100) and diastolic (ANOVA p= 0.7700) BP in the office and daytime HBP nor with nightime systolic HBP ( ANOVA p = 0.8240) and diastolic HBP(ANOVA p = 0.1530). The average systolic and diastolic BP at the Liga de Hipertensão and ABPM were higher than office and HB P (p <0001), but there was no difference in the average systolic (p= 0.077) and diastolic (p = 0.962) BP between Liga and ABPM. The diastolic HBP was lower than office diastolic BP (p = 0001). The frequency of BP values compatible with hipertension was higher at the Liga de Hipertensão (Mc Nemar p <0005), while comparisons between officedaytime HBP, office- daytime ABPM and daytime HBP-ABPM were not significant (Mc Nemar p> 0.05). The BP measurements during nightime ABPM showed a higher frequency of values compatible with hypertension than the night HBP one. Ten patients were diagnosed hypertension in the office, ABPM confirmed the diagnosis in 7 / 10 (17.5%) patients, while 5 / 10 (12.5%) were confirmed by HBP. In this group, white-coat hypertension occurred in 3 / 10 (7.5%) patients as diagnosed by the ABPM and 5 / 10 (12.5%) as diagnosed by HBP.Thirty patients presented BP values within normal limits in the office, 24 / 30 (60%) patients confirmed this diagnosis by ABPM and 26/30 (65%) by HBP. Masked hypertension was diagnosed in 6 / 30 (15%) patients diagnosed by the ABPM and in 4 / 30 (10%) by HBP. This study confirmed a correlation between ABPM and HBP measurements (Mc Nemar test p <0.01) with good reproducibility as evaluated by the Kappa index (0.557).
188

Avaliação dos indicadores biológicos de exposição aos metais em trabalhadores de fundições / Evaluation of biological indicators of exposure to metals in foundry workers

Claudia Regina dos Santos 07 December 2004 (has links)
A produção de metais sanitários é um setor em constante fase de crescimento no país. O processo industrial envolve etapas como a evaporação, condensação e oxidação dos metais no ar que levam a formação de fumos metálicos em vários tipos de indústria, inclusive em fundições. A exposição do trabalhador ao ambiente contaminado pode levar ao aparecimento de alterações bioquímicas e, em algumas circunstâncias, de doenças profissionais. No setor de metais sanitários, são utilizadas ligas metálicas de latão, onde predomina o zinco e o cobre, sendo o chumbo, cádmio, manganês e níquel, metais que aparecem sob a forma de impurezas. Desses metais, apenas o chumbo sanguíneo (Pb-S) e o cádmio urinário (Cd-U) são regulamentados no Brasil, de acordo com a NR-7 do Ministério do Trabalho, como indicadores biológicos de exposição. No presente estudo, foram otimizados e validados métodos para a determinação de Pb-S, Cd-U, Mn-U e Ni-U por espectrometria de absorção atômica acoplado a forno de grafite. Posteriormente foram avaliados 273 indivíduos do sexo masculino (178 do grupo exposto e 95 do grupo controle) que trabalhavam em 8 fundições de metais sanitários de Loanda-PR. Os níveis de Pb-S apresentaram-se elevados, considerando o limite internacional. Os metais avaliados na urina Cd-U, Mn-U e Ni-U apresentaram concentrações relativamente baixas, sendo considerado o chumbo como o principal problema, relacionado aos fumos metálicos. Foram propostas medidas corretivas nos ambientes de trabalho e os níveis dos quatro metais em questão foram reavaliados em dois períodos diferentes (antes e após as modificações), apresentando no segundo momento reduções estatisticamente significativas. As médias observadas nos dois períodos foram de 42,74&#181;g/dL e 26,54&#181;g/dL para o Pb-S; 0,269 e 0,015&#181;g/g de creatinina para o Cd-U; 1,94 e 0,39&#181;g/g de creatinina para o Mn-U e 1,82 e 0,68&#181;g/g de creatinina para o Ni-U, com níveis de significância (p) < 0,05, evidenciando assim a importância da adequação do ambiente de trabalho na garantia de exposições seguras para o trabalhador. / The sanitary metal production is a sector in constant development in Brazil. This industrial process involves stages such as evaporation, condensation and oxidation of metals, therefore allowing the formation of metallic fumes in some types of industry, and also in foundries. The contaminated environment can induce, in the workers, biochemical alterations and, in some circumstances, occupational diseases. In the sanitary metal sector, alloys are used in which predominate the metals zinc and copper, being lead, cadmium, manganese and nickel, metals that can be found in the form of impurities. According to Brazilian legislation\'s (Ministry of Work) only lead in blood and cadmium in urine are regulated as biological monitoring of exposure. In the present study, methods based on graphite furnace atomic absorption spectrometry and zeeman background correction were validated for quantification of Pb-B, Cd-U, Mn-U and Ni-U, and 273 male individuais (178 exposed group and 95 non exposed - control group), working in 8 sanitary metal foundries, in Loanda, Paraná, a state located in the south of Brazil, were evaluated. The levels of Pb-B were higher than the international permissible limit. Relatively low concentrations were found for the other evaluated metals: Cd-U, Mn-U and Ni-U, thus lead can be considered, in this case, the main problem, associated with metallic fumes. Corrective measures in the work environment were proposed and implemented, thus the four metais were evaluated in two distinct situations (biological determinations were done before and after the modifications). The results of the second evaluation showed reductions those were statistically significant. The means obtained in the two determinations were 42,74&#181;g/dL and 26,54&#181;g/dL for Pb-B; 0,269 and 0,015&#181;g/g creatinine for Cd-U; 1,94 and 0,39&#181;g/g creatinine for Mn-U and 1,82 and 0,68&#181;g/g creatinine for Ni-U, with leveis of significance (p) < 0,05, thus evidencing the importance of the adequacy of the work environment in the guarantee of safe exposures for the workers.
189

Desenvolvimento e implementação de um sistema de monitoramento de integridade estrutural baseado em rede de sensores

NUNES, Flávio Hernan Figueiredo 12 August 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-09T18:45:06Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoSistema.pdf: 40824930 bytes, checksum: 715f292ee47a5537f2fc0950ac3a15b3 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-11T12:59:03Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoSistema.pdf: 40824930 bytes, checksum: 715f292ee47a5537f2fc0950ac3a15b3 (MD5) / Made available in DSpace on 2017-01-11T12:59:03Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoSistema.pdf: 40824930 bytes, checksum: 715f292ee47a5537f2fc0950ac3a15b3 (MD5) Previous issue date: 2016-08-12 / CVRD - Companhia Vale do Rio Doce / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / Este trabalho tem como objetivo mostrar o desenvolvimento de um sistema para monitoramento de integridade estrutural, empregando rede de sensores. O projeto do nó sensor permite que este seja configurável, ao ponto de aceitar diversos tipos de sensores, tais como extensômetro, acelerômetro, sensor de temperatura, sensor de umidade, tendo também sido previsto o uso das tecnologias de comunicação com e sem fio.Ao contrário dos sistemas convencionais que são centralizados empregando longos cabos, o uso de uma rede de sensores é uma abordagem descentralizada, permitindo que os sensores fiquem mais próximos do circuito condicionador. Isso traz alguns benefícios, como a redução do comprimento dos cabos dos sensores, diminuição da captacão de ruído eletromagnético e a diminuição da impendância dos cabos, melhorando a resposta dos sinais gerado pelos sensores. São apresentados detalhes do circuito e da comunicação do nó sensor. E por ultimo são mostrados e discutidos os testes realizados. / The objective of this dissertation is show the design of a structural integrity monitoring system, employing sensor network. The project of sensor node allows many kind of sensors, such as electrical strain gage, accelerometer, temperature sensor, humidit sensor, also the sensor node is capable of communicating via wireless and wired technology. In contrast to conventional systems that are centralized and employ long cables, the use of a sensor network is a decentralized approach, allowing the sensors are closer to the conditioning circuit, this brings certain bene_ts, such as reducing the length of the sensor cables decreasing the uptake of electromagnetic noise and decrease the impedance of the cable, improving the response signals generated by sensors. They will be presented details of the circuit and the sensor node communication.
190

Linguagem de comunicação entre aplicações de gestão autónomas

Marques, Bruno Filipe Lopes Garcia January 2000 (has links)
Dissertação apresentada para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores (Área de especialização de Informática Industrial), na Faculdade de Engenharia da Universidade do Porto, sob a orientação do Professor Doutor Raúl Filipe Teixeira de Oliveira

Page generated in 0.056 seconds