• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 18
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 327
  • 168
  • 87
  • 83
  • 82
  • 66
  • 63
  • 58
  • 57
  • 41
  • 39
  • 33
  • 30
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Eficácia das tecnologias de suporte no tratamento cirúrgico dos gliomas insulares / Efficacy of assistive technologies in the surgical treatment of insular gliomas

Barbosa, Breno José Alencar Pires 08 September 2016 (has links)
Introdução: No campo do tratamento cirúrgico de Gliomas, tem se observado um interesse crescente no uso de novas tecnologias de suporte como métodos auxiliares na obtenção do equilíbrio entre radicalidade cirúrgica e preservação da funcionalidade cerebral. Na maior parte dos estudos, a localização tumoral tem sido pouco considerada e a real eficácia das tecnologias de suporte ainda está pouco investigada nos gliomas insulares. Objetivos: avaliar a eficácia da fluorescência intraoperatória com 5-ALA, monitorização neurofisiológica, neuronavegação e tractografia no grau de ressecção tumoral (GRT), escores de funcionalidade, sobrevida global e sobrevida livre de progressão em uma coorte retrospectiva de gliomas insulares. Métodos: revisamos todos os casos de tumores insulares operados no Departamento de Neurocirurgia da Universidade de Tübingen - Alemanha, entre maio de 2008 e novembro de 2013. O grau de ressecção foi avaliado por volumetria. Foram utilizados os testes de Mann Whitney, Qui-quadrado e funções de Kaplan Meier para análise do efeito de cada tecnologia nos desfechos primários e secundários. Resultados: 28 casos - 18 homens (64%) e 10 mulheres (36%); idade média 52,5 anos (12 - 59) - foram inclusos para análise. Gliomas de alto grau corresponderam a 20 casos (71%), com 8 lesões de baixo grau (29%). As tecnologias mais utilizadas foram monitorização neurofisiológica (64%) e neuronavegação (68%). 5-ALA foi a única modalidade associada a taxas de ressecção > 90% (p = 0,05). O uso de tractografia determinou melhora no KPS (50% vs 5%, p = 0,02). Houve associação positiva entre o uso de neuronavegação e sobrevida global (23 vs. 27,4 meses, p = 0,03), mas o uso de 5-ALA se associou a piora na sobrevida global (34,8 vs 21,1 meses, p = 0,01) e sobrevida livre de progressão (24,4 vs. 11,8 meses, p = 0,01). Conclusões: Considerando os gliomas insulares, o presente trabalho demonstra pioneiramente que o uso de 5-ALA tem papel na obtenção de maiores taxas de ressecção, ainda que este achado possa estar associado a piora nas sobrevidas global e livre de progressão. Tractografia e neuronavegação parecem desempenhar papel importante no tratamento dos gliomas insulares, na medida em que determinaram melhor sobrevida global e funcionalidade, respectivamente. Estudos prospectivos com uma amostra mais proeminente e análise multivariada permitirão a avaliação do benefício real destas tecnologias de suporte no tratamento dos gliomas insulares / Introduction: In the field of Glioma surgery, there has been an increasing interest in the use of assistive technologies to overcome the difficulty of preserving brain function while improving surgical radicality. In most reports, tumor localization has seldom been considered a variable and the role of intraoperative adjuncts is yet to be determined for gliomas of the insula. Objectives: to evaluate the efficacy of fluorescence-guided resection with 5-ALA, intraoperative neurophysiological monitoring (IOM), neuronavigation, and tractography in the Extent of Resection (EOR), functionality scores, overall survival (OS) and progression-free survival (PFS) in a retrospective cohort of insular gliomas. Methods: we reviewed all cases of insular tumors operated on at the Department of Neurosurgery, University Hospital of Tübingen - Germany, between May 2008 and November 2013. EOR was determined by volumetric analysis. Mann Whitney, Chi-square and Kaplan Meier functions were used for assessment of each technology\'s effect on primary and secondary outcomes. Results: 28 cases (18 men (64%) and 10 women (36%); median age at diagnosis: 52.5 years, range 12 - 59) were considered eligible for analysis. High grade and low grade gliomas accounted for 20 (71%) and 8 (29%) cases, respectively. The most used technologies were IOM (64%) and Neuronavigation (68%). 5-ALA was the only technique associated with EOR > 90% (p = 0.05). Tractography determined improvement in the Karnofsky Performance Scale (50% vs 5% cases improved, p = 0.02). There was a positive association between the use of neuronavigation and overall survival (23 vs. 27.4 months, p = 0.03), but the use of 5-ALA was associated with shorter OS (34.8 vs. 21.1 months, p = 0.01) and PFS (24.4 vs. 11.8, p = 0.01). Conclusions: we demonstrate for the first time that for insular gliomas 5-ALA plays a role in achieving higher EOR, although this technology was associated with poor OS and PFS; Also tractography and neuronavigation can be of great importance in the treatment of insular gliomas as they determined better functionality and overall survival in this study, respectively. Prospective studies with a more prominent sample and proper multivariate analysis will help determine the real benefit of these adjuncts in the setting of insular gliomas
212

"Monitorização ambulatorial da pressão arterial de pacientes com oclusão do ramo da veia central da retina" / Blood pressure monitoring of branch retinal vein occlusion patients

Rosa, Alexandre Antonio Marques 24 November 2005 (has links)
Avaliou-se a prevalência de hipertensão arterial sistêmica (HAS) e a variação circadiana da pressão arterial (PA), através da Monitorização ambulatorial da pressão arterial (MAPA), em pacientes com oclusão do ramo da veia central da retina (ORVCR). Foram avaliados, prospectivamente, 93 casos/olhos de 83 pacientes. A ausência do descenso fisiológico da PA durante o sono ("non-dipper") foi definida como diminuição da pressão sistólica = 10% e a presença de descenso quando este valor fosse maior ("dipper"). Há uma prevalência extremamente alta (94%) de HAS em pacientes com ORVCR. Entre os hipertensos, uma grande parcela dos indivíduos "non-dipper" (n=34; 44,2%). Estas evidências sugerem que um nível mais sustentado de PA nas 24 horas possa ser um fator de risco para o desenvolvimento da ORVCR / Objective: Identifying with Blood pressure monitoring (BPM) in patients with branch retinal vein occlusion (BRVO): high blood pressure (HBP) prevalence, possible cases of white-coat normotension (WCNT) and variation of circadian blood pressure (BP). Methods: Prospectively, 93 cases/eyes of 83 patients with BRVO were evaluated at Ophthalmological Clinic of "Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo" (HCFMUSP). After that, patients were taken to Hypertension League of Nephrology Chair of HCFMUSP (LH-HCFMUSP) for clinical evaluation and blood pressure monitoring. Non-dipper was defined as a fall in systolic blood pressure = 10%, and dipper when this value was higher
213

Monitorização residencial da pressão arterial (MRPA) no controle da pressão arterial de pacientes em hemodiálise / Home blood pressure monitoring (HBPM) in the blood pressure control in hemodialysis patients

Silva, Giovanio Vieira da 25 August 2008 (has links)
INTRODUÇÃO: Não se sabe se o ajuste da terapia anti-hipertensiva baseado na Monitorização Residencial da Pressão Arterial (MRPA) pode melhorar o controle da pressão arterial em pacientes em hemodiálise. OBJETIVOS: Comparar a redução da pressão arterial (PA) e do índice de massa ventricular esquerda (IMVE) obtido com o uso da MRPA em relação às medidas da PA pré-diálise em pacientes em hemodiálise. MÉTODOS: Pacientes hipertensos em hemodiálise foram randomizados para ter a terapia anti-hipertensiva ajustada em dois grupos: controle, baseado na PA pré-diálise, e intervenção, baseada na MRPA. Antes e após 06 meses de acompanhamento, os pacientes realizaram Monitorização Ambulatorial da Pressão Arterial (MAPA) por 24 horas, MRPA durante uma semana e ecocardiograma transtorácico. RESULTADOS: 34 e 31 pacientes completaram o estudo no grupo intervenção e controle, respectivamente. As pressões arteriais sistólica (PAS) e diastólica (PAD) no período interdialítico pela MAPA foram significativamente menores no grupo intervenção em relação ao grupo controle no final do estudo (média 24 horas: 135 ± 13mmHg / 76 ± 7mmHg versus 147 ± 15mmHg / 79 ± 8mmHg, respectivamente - p<0,05). Na análise da MRPA, o grupo intervenção apresentou redução significativa somente para a PAS em comparação ao grupo controle (média semanal: 144 ± 21mmHg versus 154 ± 22 mmHg, respectivamente - p<0,05). Não houve diferenças entre os grupos intervenção e controle em relação ao IMVE ao final do estudo (108 ± 35 g/m2 versus 110 ±33 g/m2, respectivamente - p>0,05). CONCLUSÕES: O uso sistemático da MRPA no ajuste da terapia anti-hipertensiva em pacientes em hemodiálise propiciou maior controle da PA no período interdialítico em comparação às medidas da PA pré-diálise. A MRPA pode ser usada como um instrumento adjuvante útil no controle da pressão arterial em pacientes em hemodiálise / INTRODUCTION: It is not known whether the adjustment of the antihypertensive therapy based on Home Blood Pressure Monitoring (HBPM) can improve blood pressure (BP) control in hemodialysis patients. OBJECTIVES: To compare the reduction in BP and in the left ventricular mass index (LVMI) obtained with the use of HBPM in relation to that achieved with predialysis BP measurements in hemodialysis patients. METHODS: Hypertensive patients on hemodialysis were randomized to have the antihypertensive therapy adjusted according two groups: control, based on the predialysis BP measurements, and intervention, based on HBPM. Before and after 06 months of follow-up, patients were submitted to Ambulatory Blood Pressure Monitoring (ABPM) for 24 hours, HBPM during one week and transthoracic echocardiogram. RESULTS: 34 and 31 patients completed the study in the intervention and control groups, respectively. The systolic (SBP) and diastolic (DBP) blood pressure in the interdialytic period by ABPM were significantly lower in the intervention group compared with the control group at the end of the study (mean 24-hours BP: 135 ± 13 mm Hg / 76 ± 7 mmHg versus 147 ± 15 mm Hg / 79 ± 8 mmHg, respectively - p <0.05). When the interdialytic BP was analysed by HBPM, the intervention group showed significant reduction only for the PAS in comparison with control group (mean weekly BP: 144 ± 21 mm Hg versus 154 ± 22 mm Hg, respectively - p <0.05). There were no differences between intervention and control groups in relation to LVMI at the end of the study (108 ± 36 g/m2 versus 110 ± 33 g/m2, respectively - p> 0.05). CONCLUSIONS: The systematic use of HBPM in the adjustment of antihypertensive therapy in patients on hemodialysis has led to better control of BP during interdialytic period compared to that achieved with the predialysis BP measurements. The HBPM can be used as a useful adjunct instrument to control blood pressure in hemodialysis patients
214

Critérios eletrofisiológicos de prognóstico da função facial baseados no pontencial evocado motor do nervo facial intraoperatório durante os diversos tempos cirúrgicos da cirurgia do schwannoma vestibular / Electrophysiological parameters of facial motor evoked potential predict postoperative facial function during vestibular schwannoma resection

Sousa, Marcus André Acioly de 26 October 2011 (has links)
O potencial evocado motor facial (PEMF) tem-se mostrado um excelente método de monitorização do nervo facial, gerando resultados bastante confiáveis e reprodutíveis no que tange à predição da função facial pós-operatória. O critério eletrofisiológico mais utilizado até então para tanto tem sido a relação de amplitude do PEMF final-valor de base. Os objetivos deste trabalho foram avaliar as alterações intraoperatórias da amplitude e da complexidade do PEMF, correlacioná-las com o prognóstico facial no pós-operatório imediato e tardio e verificar se amplitude e complexidade constituem variáveis independentes de predição funcional. Os registros dos potenciais intraoperatórios dos músculos orbiculares do olho e da boca de 35 pacientes portadores de schwannoma vestibular (SV) foram coletados e analisados retrospectivamente de acordo com tempos cirúrgicos preestabelecidos: inicial, abertura da dura-máter, dissecação do tumor (TuDis), ressecção do tumor (TuRes) e final. No pós-operatório imediato, a função facial apresentou uma significativa correlação negativa com as relações de amplitude do PEMF durante a TuDis, a TuRes e ao final do procedimento nos músculos orbiculares do olho (p =0,003, 0,055 e 0,028, respectivamente) e da boca (p=0,002, 0,104 e 0,014, respectivamente). No último seguimento, entretanto, a correlação foi significativa apenas para o músculo orbicular da boca, durante a TuDis (p=0,005) e ao final do procedimento (p=0,102). As variações da complexidade dos potenciais alcançaram resultados mais significativos tanto no pós-operatório imediato, quanto no tardio, de forma que houve uma correlação negativa no músculo orbicular do olho apenas nas medidas finais (imediato, p=0;023; seguimento, p=0,116) e no músculo orbicular da boca durante a TuDis, a TuRes e a medida final (imediato, p=0,071, 0,000 e 0,001, respectivamente; seguimento, p=0,015, 0,001 e 0,01, respectivamente). As alterações intraoperatórias das relações de amplitude e de complexidade dos PEMFs parecem representar variáveis independentes, podendo ser utilizadas na predição da função facial pós-operatória durante cirurgias de ressecção de SV. Baseados nos resultados deste trabalho, a monitorização evento-valor de base é bastante útil, justificando mudanças imediatas da estratégia cirúrgica, com o intuito de reduzir as chances de uma lesão definitiva do nervo facial. / Facial motor evoked potential (FMEP) amplitude ratio reduction at the end of the surgery has been identified as a good predictor for postoperative facial nerve outcome. We sought to investigate variations in FMEP amplitude and waveform morphology during vestibular schwannoma (VS) resection and to correlate these measures with postoperative facial function immediately after surgery and at the last follow-up. Besides we analyzed the relationship between quantitative parameters. Intraoperative orbicularis oculi and oris muscles FMEP data from 35 patients undergoing surgery for VS resection were collected, then analyzed by surgical stage: initial, dural opening, tumor dissection (TuDis), tumor resection (TuRes) and final. Immediately after surgery, postoperative facial function correlated significantly with the FMEP amplitude ratio during TuDis, TuRes and final in both the orbicularis oculi (p´s=0.003, 0.055 and 0.028, respectively) and oris muscles (p´s=0.002, 0.104 and 0.014, respectively). At the last follow-up, however, facial function correlated significantly with the FMEP amplitude ratio only during TuDis (p=0.005) and final (p=0.102) for the orbicularis oris muscle. At both time points, postoperative facial paresis correlated significantly with FMEP waveform deterioration in orbicularis oculi during final (immediate, p=0.023; follow-up, p=0.116) and in orbicularis oris during TuDis, TuRes and final (immediate, p´s=0.071, 0.000 and 0.001, respectively; follow-up, p´s=0.015, 0.001 and 0.01, respectively). FMEP amplitude ratio and waveform morphology during VS resection seem to represent independent quantitative parameters that can be used to predict postoperative facial function. Event-to-baseline FMEP monitoring is quite useful to dictate when intraoperative changes in surgical strategy are warranted to reduce chances of facial nerve injury.
215

Monitorização terapêutica da agomelatina, sertralina e venlafaxina / Therapeutic monitoring of agomelatine, sertraline and venlafaxine

Moura, Bruna Cordeiro Santos de 04 December 2014 (has links)
Atualmente, a quantidade de pacientes que são diagnosticados com alguma forma de depressão, entre elas, o transtorno depressivo maior, aumenta consideravelmente, quer seja em razão de diagnósticos mais precisos ou pela própria epidemiologia da doença. Acresça-se o fato de que muitos pacientes, apesar da quantidade de tipos de antidepressivos atualmente disponíveis para a terapêutica, são refratários ao tratamento prescrito, em razão dos efeitos adversos apresentados ou ainda em razão de simplesmente não se observar melhora com a prescrição. Em razão disso, novos tratamentos farmacológicos são disponibilizados. Para auxiliar na máxima eficácia em sua utilização, esse trabalho propôs o desenvolvimento de metodologia analítica para a determinação simultânea de antidepressivos tricíclicos e não tricíclicos, a saber: moclobemida, venlafaxina, citalopram, agomelatina, duloxetina, amitriptilina e sertralina em plasma humano por cromatografia líquida de alta eficiência (HPLC), para posteriormente ser aplicada na monitorização de pacientes depressivos. O método consistiu na extração líquido-líquido com recuperação entre 73% a 86%, exceto para a moclobemida (55%). A separação foi obtida usando uma coluna em fase reversa LiChrospher® 60 RP-select B em LichroCART 250mm x 4mm, 5 ?m de diâmetro interno, Merck sob condições isocráticas com detecção em UV em 230 nm, com fase móvel composta por 35% de uma mistura de acetonitrila/metanol 55/5 v/v e 65% de tampão acetato 0,25M pH 4,4. As curvas padrão foram lineares em uma faixa de trabalho de 2,5-1000 ng/mL para moclobemida, 5-2000 ng/mL para venlafaxina, citalopram, agomelatina, duloxetina e amitriptilina, 10-2000 ng/mL para sertralina. A precisão intra e interensaios foi efetuada em 3 concentrações (50, 200 e 500 ng/mL). Os coeficientes de variação para a precisão intraensaio foram menores que 8,8% para todos os compostos e os coeficientes de variação para a precisão interensaios foram menores que 8,6%. Os limites de quantificação foram de 2,5 ng/mL para a moclobemida, 5 ng/mL para venlafaxina, citalopram, duloxetina, agomelatina, amitriptilina e 10 ng/mL para sertralina com a etidocaína como padrão interno. Não se observou qualquer interferência das drogas normalmente associadas com antidepressivos. O método desenvolvido foi aplicado na monitorização de 79 pacientes em tratamento prolongado com amitriptilina, sertralina e venlafaxina. Paralelamente, foram avaliadas as concentrações plasmáticas de pacientes voluntários sadios submetidos a tratamento em dose única com agomelatina. A monitorização terapêutica se faz necessária para monitorar adesão ao tratamento já que a depressão está entre as principais causas mundiais de morbidade por incapacitação social e estimativa de prevalência crescente até 2030; caracterizando-se como um dos maiores e mais onerosos problemas de saúde pública. / Currently, the number of patients who are diagnosed with some form of depression, among them, major depressive disorder, increases considerably, either because of more accurate diagnosis or by the epidemiology of the disease. One should add the fact that many patients, despite the amount of types of antidepressants currently available for therapy are refractory to the treatment prescribed, because of the adverse effects appear, or their toxic effects, or by simply not observed improvement then the prescription. Therefore, new pharmacological treatments are available. To assist in maximum effectiveness in its use, this paper presents a methodology on HPLC for simultaneous determination of seven antidepressants, tricyclic and non-tricyclic, moclobemide, venlafaxine, citalopram, agomelatine, duloxetine, amitriptyline and sertraline in human plasma, later to be applied in monitoring depressed patients. The simple and accurate method of sample preparation consists of the liquid-liquid extraction with recovery between 73% to 86% (except for moclobemide, 55%). Separation was achieved using a reverse phase column Lichrospher® 60 RP-select B LiChroCART 4mm x 250mm, 5?m internal diameter, Merck, under isocratic conditions, with UV detection at 230nm, with a mobile phase consisting of a mixture of 35% acetonitrile:methanol 55/5 (v/v) and 65% 0.25M acetate buffer, pH 4.4. The standard curves were linear in the working range of 2,5-1000 ng/mL for moclobemide, 5-2000 ng/mL to venlafaxine, citalopram, agomelatine, duloxetine and amitriptyline and 10-2000ng/mL to sertraline. The intra and interassay precisions were performed at three concentrations (50, 200 and 500 ng/mL). The coefficients of variation for intra-assay precision were less than 8.6% for all compounds and the coefficients of variation for interassay precision were lower than 8.5%. The limits of quantification were 2.5 ng/mL for moclobemide, 5 ng/mL for venlafaxine, citalopram, duloxetine, agomelatine, amitriptyline and 10 ng/mL for sertraline. No interference of drugs normally associated with antidepressants was observed. The developed method was applied to the monitoring of 79 patients receiving prolonged treatment with amitriptyline, sertraline and venlafaxine. And, the plasma concentrations of healthy volunteer patients undergoing single dose agomelatine were evaluated. Therapeutic drug monitoring, is to ensure maximum clinical efficacy coupled with minimal adverse effects in patients undergoing long-term therapy is needed and to monitor adherence to treatment since depression is among the major causes of morbidity and social disability increasing prevalence estimate of 2030; characterized as one of the largest and most costly public health problems
216

Análise crítica do decaimento no nível do paratormônio intra-operatório para prognóstico de sucesso da paratireoidectomia no controle precoce do hiperparatireoidismo secundário e terciário / Critical analysis of the decrease in the level of intraoperative parathyroid hormone for the prognosis of successful parathyroidectomy in the early control of secondary and tertiary hyperparathyroidism

Silveira, André Albuquerque 12 December 2018 (has links)
INTRODUÇÃO: A monitorização do paratormônio rápido (PTHr) é padrão no tratamento cirúrgico do hiperparatireoidismo primário, para garantir a retirada da paratireoide doente e preservação das saudáveis. Sua utilidade no tratamento cirúrgico do hiperparatireoidismo secundário à doença renal crônica é controversa. Esse estudo tem como objetivo verificar: 1) se a medida PTHr auxilia na predição do resultado cirúrgico precoce; 2) se existem diferenças de comportamento do PTHr entre pacientes dialíticos e transplantados; 3) se existem diferenças de comportamento do PTHr entre modalidades de operações distintas; 4) a acurácia do método em predizer controle do hiperparatireoidismo renal. MÉTODOS: Trata-se de estudo de coorte retrospectiva e prospectiva observacional, de pacientes com diagnóstico de HPTr, dialítico ou persistência após transplante renal, submetidos a paratireoidectomia total ou subtotal em único centro, no período de 2011 a 2016. Durante a cirurgia, realizamos coletas seriadas do PTHr, sendo três dessas amostras antes da exérese das glândulas paratireoides (basal periférico, basal central e pré-retirada), e duas após ressecção (10 min e 15 min). O critério de queda porcentual igual ou maior a 80% do maior valor entre as amostras basais, em 10 minutos, foi arbitrado preditor de êxito intra-operatório. Os pacientes foram seguidos durante intervalos regulares (15 dias, 3, 6 e 12 meses). Foram divididos em dois grupos (sucesso e falha da operação) de acordo com o controle dos níveis de PTH, cálcio e fósforo conforme consensos internacionais, ao término do seguimento de 1 ano. RESULTADOS: Duzentos e vinte e oito pacientes foram elegíveis, sendo 186 (81,6%) dialíticos e 42 (18,4%) transplantados. A paratireoidectomia alcançou sucesso em 92,1% (210/228) e falha em 7,9% (18/228) dos pacientes, sem diferenças de resultados entre grupos de diagnósticos diferentes e/ou tipos de operações distintas. O principal motivo de falha foi presença de glândula supranumerária, em 61,1% dos casos (11/18). A amostra basal central (BC) representou o real maior valor basal do PTHr para ambos os diagnósticos, porém com maior chance de picos do PTHr na amostra pré-retirada (PRE) nos pacientes transplantados. Após remoção da massa de tecido paratireóideo doente, os níveis de PTHr foram menores em 10 minutos quando comparados com as amostras basais (resultado estatisticamente significativo) para todos diagnósticos, tipos de operações e desfechos terapêuticos. No grupo sucesso, houve diferença estatisticamente significativa, entre as medidas de 10 e 15 minutos entre si, com valores menores em 15 minutos, enquanto que no grupo falha, sem distinção de 10 e 15 minutos entre si e com valores médios maiores em 15 min. Os valores do PTHr foram maiores no paciente dialítico quando comparados com transplantado, em todas as amostras (p < 0,001). No grupo sucesso, os pacientes dialíticos e transplantados, e os pacientes dialíticos submetidos a exérese total e subtotal apresentaram porcentual de queda do PTHr semelhantes em 10 e 15 minutos para as amostras BC e PRE; o paciente transplantado obteve decaimentos porcentuais menores quando houve ressecção subtotal. O grupo falha apresentou queda porcentual nitidamente menor e com significância estatística (p < 0,001), para todas amostra basais e em qualquer momento, quando comparado ao grupo sucesso. A função renal pré-operatória dos transplantados não influenciou a cinética de decaimento do PTHr (não teve correlação, p=0,09). A monitorização do PTHr influenciou a conduta cirúrgica em 7% (16/228) da casuística; o principal motivo foi a ocorrência de localização ectópica de umas das quatros paratireoides, responsável por 75% (12/16) dos casos. A paratireiodectomia bem sucedida exibiu impacto negativo na função do enxerto renal no pós-operatório, porém com posterior recuperação ao término de 1 ano. O método da dosagem do PTHr com o critério de 80% de queda, apresentou acurácia de 87%, sensibilidade de 88% e especificidade de 67% para a amostra BC em 15 minutos, e melhor especificidade (74%) na amostra PRE em 10 min. CONCLUSÕES: Em pacientes com hiperparatireoidismo renal, uso de medidas intra-operatórias do PTHr apresenta alta sensibilidade para indicar o sucesso da operação quando há redução de 80% dos valores iniciais. Apesar de valores absolutos diferentes, as taxas de redução desse hormônio após uma paratireoidectomia bem sucedida não são significativamente diferentes em pacientes dialíticos e transplantados, em operação total com auto-enxerto ou subtotal, com efetiva queda em 10 minutos de amostragem. A utilização de uma medida adicional 15 minutos após a retirada das glândulas aumenta a acurácia do método. A medida intra-operatória do PTHr pode auxiliar na tomada de decisões durante a operação desses pacientes / INTRODUCTION: Rapid Parathyroid Monitoring (rPTH) is standard in the surgical treatment of primary hyperparathyroidism, to ensure the excision of the diseased parathyroid and preservation of healthy parathyroid glands. Its usefulness in the surgical treatment of hyperparathyroidism secondary to chronic kidney disease is controversial. This study aims to verify: 1) whether the rPTH measure assists in the prediction of the early surgical outcome; 2) whether there are differences in rPTH pattern between dialytic and transplanted patients; 3) if there are differences in the decay of the rPTH between different operations modalities; 4) the accuracy of the method in predicting control of renal hyperparathyroidism. METHODS: This is a retrospective and prospective observational cohort study of patients with a diagnosis of PTH, dialysis or persistence after renal transplantation, who underwent total or subtotal parathyroidectomy in a single center from 2011 to 2016. During surgery, we performed serial samples of the rPTH, three of these were before excision of the parathyroid glands (peripheral basal, central basal and pre-withdrawal), and two after resection (10 min and 15 min). The criterion of percentage drop equal to or greater than 80% of the highest value of the basal samples, in 10 minutes, was arbitrated predictor of intraoperative success. Patients were followed at regular intervals (15 days, 3, 6 and 12 months). They were divided into two groups (success and failure of the operation) according to the control of the levels of PTH, calcium and phosphorus according to international consensus, at the end of the 1 year follow-up. RESULTS: Two hundred and twenty-eight patients were eligible, being 186 (81.6%) dialytic and 42 (18.4%) transplanted. Parathyroidectomy achieved success in 92.1% (210/228) and failure in 7.9% (18/228) of the patients, with no differences in results between groups of different diagnoses and/or different types of operations. The main reason for failure was the presence of supernumerary glands, 61.1% of the cases (11/18). The central basal (CB) sample represented the actual higher baseline PTHr for both diagnoses, but with a higher chance of rPTH peaks in the pre-withdrawal sample (PRE) in the transplanted patients. After removal of the diseased parathyroid tissue mass, rPTH levels were lower in 10 minutes compared to baseline (statistically significant) for all diagnoses, types of operations and therapeutic outcomes. In the success group, there was a statistically significant difference between the 10 and 15 minutes measurements, with smaller values in 15 minutes, while in the failure group, there was no distinction of 10 and 15 minutes between them and with mean values greater in 15 min. The rPTH values were higher in the dialytic patient when compared to transplanted in all samples (p < 0.001). In the success group, dialytic and transplanted patients, and dialytic patients submitted to total and subtotal excision, presented similar percent drop in rPTH at 10 and 15 minutes for CB and PRE samples; the transplanted patient had lower percentage decreases when subtotal resection. The failure group had a significantly lower percentage drop and with statistical significance (p < 0.001), for all baseline and at any time, when compared to the success group. The preoperative renal function of the transplanted patients did not influence the kinetics of rPTH decay (had no correlation, p=0.09). The rPTH monitoring influenced the surgical management in 7% (16/228) of the series; the main reason was the occurrence of ectopic localization of one of the four parathyroid glands, responsible for 75% (12/16) of the cases. In transplanted patients, successful parathyroidectomy had a negative impact on renal graft function in the postoperative period, but with a subsequent recovery at the end of 1 year. The rPTH dosage method with the 80% drop criterion showed an accuracy of 87%, a sensitivity of 88% and specificity of 67% for the CB sample in 15 minutes and a better specificity (74%) in the PRE sample in 10 min. CONCLUSION: In patients with renal hyperparathyroidism, the use of intraoperative measurements of rPTH has a high sensitivity to indicate the success of the operation when there is a reduction of 80% of the initial values. In spite of different absolute values, the rates of reduction of this hormone after successful parathyroidectomy are not significantly different in dialytic and transplant patients, in total autograft or subtotal operation, with an effective drop in 10 minutes of sampling. The use of an additional measurement 15 minutes after removal of the glands increases the accuracy of the method. The intraoperative measurement of rPTH may aid in decision making during the operation of these patients
217

Desenvolvimento de fases extratoras seletivas para técnicas de microextração para a determinação de fármacos e endocanabinóide em amostras de plasma por LC-MS/MS / Selective extractive phases for microextraction techniques for determination of drugs and an endocannabinoid in plasma samples by LC-MS/MS

Melo, Mônia Aparecida Lemos Pinto de 11 August 2017 (has links)
Este trabalho descreve o desenvolvimento de seletivas fases extratoras para técnicas de microextração empregadas para a determinação de fármacos e endocanabinóide em amostras de plasma por cromatografia líquida acoplada a espectrometria de massas em Tandem (LC-MS/MS). O capítulo I descreve o desenvolvimento e aplicação da fase extratora de material de acesso restrito (RAM) para a extração em ponteiras descartáveis (DPX) de dezesseis fármacos psicotrópicos em amostras de plasma de pacientes esquizofrênicos. Em virtude da complexidade de sintomas associados à esquizofrenia, a politerapia tem sido uma prática clínica cada vez mais comum. A maioria destes fármacos possui estreito índice terapêutico, o que requer acompanhamento adequado por meio de estudos de monitorização terapêutica. Tais estudos visam otimizar as doses terapêuticas, minimizar os efeitos adversos e avaliar a anuência do paciente ao regime de dosagens. O emprego da fase seletiva, RAM, permitiu a exclusão das macromoléculas, simultaneamente, a pré-concentração dos analitos de forma rápida e eficiente. A otimização das variáveis DPX favoreceu a sensibilidade e seletividade do método, empregando pequenos volumes de amostra biológica e de solvente orgânico. O método DPX/LC-MS/MS, desenvolvido e validado, apresentou linearidade adequada com limite inferior de quantificação na faixa de concentração de 0,5-20,0 ng mL-1, precisão inter e intra-ensaio com coeficientes de variação inferiores a 15% e exatidão com valores de EPRs variando de -12% a 11%. O método proposto foi aplicado com êxito na determinação destes fármacos em amostras de plasma de pacientes esquizofrênicos. As variações encontradas nas concentrações plasmáticas de alguns pacientes podem ser atribuídas a interações farmacocinéticas ou a variações inerentes ao paciente. No capítulo II, um polímero molecularmente impresso foi sintetizado in situ, no interior de um capilar de sílica fundida, para microextração em fase sólida no capilar (in-tube SPME) do endocanabinóide, anandamida (AEA), em amostras de plasma de pacientes com Doença de Parkinson (DP). A DP é caracterizada pela neurodegeneração dos neurônios dopaminérgicos. Estudos demonstram correlação entre os sistemas endocanabinóide e dopaminérgico, ligados ao controle motor. O processo de impressão molecular (não-covalente) do MIP, bem como os reagentes de síntese empregados, originaram sítios seletivos, complementares, em forma e tamanho à AEA. Micrografias eletrônicas de varredura (MEV) e espectros de infravermelho (FTIR) ilustraram as modificações físicas e químicas da superfície do capilar impresso e não impresso (NIP), após a polimerização. A otimização das variáveis in-tube SPME, favoreceu a eficiência das extrações. O método in-tube SPME/LC-MS/MS apresentou intervalo linear de 5 ng mL-1 (LOQ) a 20 ng mL-1; os ensaios de precisão apresentaram CV variando de 1,2 a 13% e exatidão com valores de EPRs variando de -3,6 a 7,5 %. Amostras de plasma de pacientes com DP foram analisadas pelo método de adição de padrão, e a concentração plasmática média de AEA de 0,2 ng mL-1, está em concordância com os valores da literatura, demonstrando a aplicabilidade do método in-tube SPME/LC-MS/MS na área clínica. / This work describes the development of highly selective sorbents for use in microextraction techniques for determination of drugs and endocannabinoid in plasma samples by liquid chromatography coupled to Tandem mass spectrometry (LC-MS/MS). Chapter I describes the development and application of a restricted access material (RAM-BSA) for use as extractive phase in DPX technique (\"Disposable pipette extraction\") for determination of 16 psychotropic drugs in plasma samples obtained from schizophrenic patients. Polytherapy has been increasingly common in clinical practice associated with schizophrenia due the complexity of its symptoms. Most of these drugs have narrow therapeutic index, wherefore requires adequate follow-up through therapeutic monitoring studies. This monitoring aims to optimizing therapy, to minimize adverse effects and verify patient adherence to treatment. By using a selective phase, RAM, we were able to exclude the macromolecules and to pre-concentrate the analytes quickly and efficiently. Optimization of the DPX variables improved the sensitivity and selectivity of the method, which demanded only small volumes of sample and organic solvent. The DPX/LC-MS/MS method developed and validated presented adequate linearity; the lower limit of quantification ranged from 0.5 to 20.0 ng mL-1. The inter- and intra-assay precision tests provided coefficients of variation (CV) lower than 15%; and the relative standard error (RSD) values, of the accuracy tests, varied from -12% to 11%. We successfully applied the proposed method to determine drugs in plasma samples from schizophrenic patients. Variations in the plasma concentrations of drugs in some patients may result from pharmacokinetic interactions or variations inherent in the patient. Chapter II details the \"in situ\" synthesis of a molecularly imprinted polymer within a fused silica capillary for capillary solid phase (in-tube SPME) of the endocannabinoid, anandamide (AEA), in plasma samples obtained from patients with Parkinson\'s Disease (PD), which is characterized by neurodegeneration of dopaminergic neurons. Studies have demonstrated a relationship between this endocannabinoid and dopaminergic systems, which are linked to motor control. The molecular imprinting process (non-covalent) and the synthesis reagents used to obtain the MIP gave rise to complementary, selective sites with the same shape and size as AEA. Scanning electron micrographs (SEM) and infrared spectra (FTIR) helped to illustrate the physical and chemical modification of the printed and non-printed capillary surface (NIP) after polymerization. Optimization of in-tube SPME variables favored the extraction process efficiency. The \"in tube\" SPME/LC-MS/MS method showed a linear range from 5 ng mL-1 (LOQ) to 20 ng mL-1. The precision tests presented CV that varied from 1.2 to 13%; and the RSD accuracy ranged from -3.6 to 7.5%. We analyzed plasma samples from patients with PD by the standard addition method. The mean plasmatic concentration was 0.2 ng mL-1, in agreement with the literature. This resut suggested that the \"in tube\" SPME/LC-MS/MS employing the MIP extractive phase is suitable to determine AEA in plasma samples
218

Uso da medida da pressão em casa como estratégia de controle da pressão arterial de um grupo de hipertensos  de Peruíbe - SP / Use of home blood pressure measurement as a control strategy in a group of hypertensive patients from Peruibe SP

Silva, Giane Christina Alves da 29 November 2010 (has links)
Introdução: a falta de controle dos hipertensos tem sido um desafio para os profissionais de saúde, e a medida da pressão em casa pode ser um recurso para aumentar o controle da pressão arterial. Realizou-se um estudo para avaliar o efeito do uso da medida da pressão em casa no controle da pressão arterial em um grupo de hipertensos. Objetivos: avaliar o efeito do uso da medida da pressão em casa no controle da pressão arterial em grupo de hipertensos do Município de Peruibe SP. Objetivos específicos: 1- comparar o controle da pressão arterial dos hipertensos submetidos à medida da pressão em casa; 2- avaliar o controle da pressão arterial dos hipertensos, considerando a monitorização residencial da pressão (MRPA) como método de avaliação pré e pós-medida da pressão em casa; 3- identificar associações entre o controle da pressão arterial com as variáveis biopsicossociais, hábitos de vida, comportamentos e atitudes frente à doença e tratamento; 4- avaliar adesão ao tratamento utilizando o questionário Fatores Dificultadores da Adesão (FDA) e o teste de Morisky e Green. Casuística e Método: pesquisa de campo, longitudinal, pareada com abordagem quantitativa. Os participantes realizaram a medida da pressão arterial em consultório no início e final do estudo. A medida da pressão em casa foi realizada com aparelho automático, validado durante 8 semanas às segundas, quartas e sextas-feiras pela manhã (entre 6 e 10h) e à noite (entre18 e 22h). A utilização da monitorização residencial da pressão arterial (MRPA), no início e no final do estudo, teve o propósito de avaliar a eficácia do uso da medida da pressão em casa, como estratégia de aumento do controle da pressão arterial, foi realizada nas semanas 1 e 10 durante 7 dias com o mesmo aparelho, três medidas pela manhã (entre 6 e 10h) e 3três medidas à noite (entre18 e 22h) na posição sentada com 10 minutos de repouso e com manguito adequado. Os valores de p<0,05 foram considerados significantes. Exames de glicemia em jejum, colesterol total e frações, triglicérides, ureia e creatinina foram coletados. Avaliou-se adesão com o questionário fatores dificultadores da adesão e o teste de Morisky e Green, presença de transtornos mentais comuns com o Self Report Questionnaire (SRQ 20), risco de danos à saúde relacionado ao uso de bebidas alcoólicas com o questionário Alcohol Use Disorders Identification (AUDIT) e suporte social com a Escala de Apoio Social. Resultados: foram estudados 71 hipertensos com idade de 63,3±11 anos; 53,5% homens; 77,5% brancos; 77,1% ensino fundamental/médio; 53,5% aposentados; 52,1% renda 2 salários mínimos e não tabagista;19,7% sedentários; índice de massa corporal 30,8±5,8 kg/m2; 35,2% etilista, 43,7% aderentes ao teste de Morisky e Green e 32,4% positivos para o SRQ-20. Destaca-se que em 19 das 25 perguntas do formulário fatores dificultadores da adesão, foi obtido percentual acima de 90% no apontamento dos fatores que menos dificultam o tratamento, os maiores percentuais de concordância foram para as questões: chegar à consulta e não ter médico (36,6%), o tempo de espera para consulta é longo e não estar melhorando da pressão (16,9% e 14,1% respectivamente). Exames laboratoriais: glicemia 121,3±43,6 mg/dL, colesterol total 204,8±41,6 mg/dL, HDL 48,5±11,25 mg/dL, VLDL 29,5±15,2 mg/dL, LDL 123,6±39,2 mg/dL, triglicérides 150,1±88 mg/dL, ureia 45,1±16,4 mg/dL e creatinina 1,0±0,5 mg/dL. Houve diminuição significativa (p<0,05) da pressão arterial na MRPA inicial em relação à final 144,9±15,7 vs 140,6±16,8 mmHg para pressão sistólica matutina, 145,7±18,0 vs 141,7±17,5 mmHg para pressão sistólica noturna, 85,8±9,4 vs 83,5±9,6 mmHg para diastólica matutina e 84,5±9,9 vs 81,8±9,3 mmHg para diastólica noturna. Na medida da pressão em casa, diminuição significativa foi observada na comparação das primeira e oitava semanas 144,4±17,3 vs 139,3±15,9 mmHg para sistólica matutina, 144,7±19,8 vs 140,8±17,8 mmHg para sistólica noturna, 86,8±18,8 vs 82,7±10,1mmHg para diastólica matutina, 83,2±10,5 vs 82,2±10,4 mmHg para diastólica noturna. Na medida de consultório também houve diminuição significativa (p<0,05) entre a do início do estudo e o final (157,6±13,6 / 91,4±8,3 vs 146,9±19,9 / 85,1±11,5 mmHg). Dessa forma, a diminuição no percentual de hipertensos controlados foi: 67,6% e 57,7% na MRPA e 73,2% e 70,4% na medida de consultório, para as pressões sistólica e diastólica, respectivamente. A análise multivariada mostrou que o controle da pressão arterial associou-se com: a) sistólica na medida residencial: teste de Morisky e Green (OR: 0,187; IC 95%; 0,57-0,619) e o domínio crenças pessoais do questionário fatores dificultadores da adesão (OR: 0,696; IC 95%; 0,502-0,965); b) diastólica na medida em casa: idade entre 55 e 65 anos (OR: 0,138; IC 95%; 0,030-0,637), idade acima de 65 anos (OR: 0,216; IC 95%; 0,055-0,845 e prática de esportes (OR: 0,179; IC 95%; 0,044-0,730); c) diastólica de consultório: Self Report Questionnaire - SRQ-20 (OR: 8,746; IC 95%; 2,243-34,103), HDL - colesterol < 40 e 40-59 mg/dL (OR: 3,644; IC 95%; 0,338-39,338) e HDL - colesterol 60 mg/dL (OR: 37,323; 95%; 2,079-670,022); d) sistólica e diastólica na MRPA: variável domínio institucional do instrumento fatores dificultadores da adesão (OR: 1,260; IC 95%; 1,036-1,533) e (OR: 1,212; IC 95%; 1,003-1,464). Conclusão: a estratégia de controle da medida da pressão arterial em casa foi eficiente para o aumento do controle da pressão arterial desse grupo de hipertensos. / Introduction Hypertensive patients lack of control has been a challenge for health professional, and home pressure measurement can be a resource to enhance blood pressure control. General aim: To assess the effect of using home pressure measurement on blood pressure control in a group of hypertensive patients from Peruibe SP. Specific aims: 1- To compare the blood pressure control of hypertensive patients submitted to home pressure measurement. 2- To assess the blood pressure control of hypertensive patients, considering home blood pressure monitoring (HBPM) as the pre and post home pressure measurement assessment method. 3- To assess treatment adherence using the Inhibiting Factors of Adherence (IFA) questionnaire and the Morisky and Green test. 4- To identify associations between blood pressure control and biopsychosocial variables, life habits, behaviors and attitudes towards the disease and treatment. Cases and Method: Longitudinal field research combined with a quantitative approach. The study was carried out in Peruíbe-SP, at the Hypertension and Diabetes Referral Center and the medical specialty outpatient clinic. The nurse performed outpatient blood pressure measurement at the start and end of the study. The patient measured blood pressure at home, using a validated automatic device, during 8 weeks, on Monday, Wednesday and Friday mornings (between 6 and 10 a.m.) and nights (between 18 and 22h). Home blood pressure monitoring (HBPM) was performed at the start and end of the study, in week 1 and 10, during 7 days, using the same device, with three measures in the morning (between 6 and 10h) and 3 measures at night (between 18 and 22h), in the sitting position, after a ten-minute rest and using an adequate cuff. Fasting glucose, total cholesterol and fractions, triglycerides, urea and creatinine tests were also performed. Treatment adherence was assessed with the Inhibiting Factors of Adherence (IFA) questionnaire and the Morisky and Green test. The presence of common mental disorders was assessed with the Self Report Questionnaire (SRQ 20), the risk for health damage related to the use of alcoholic beverages with the Alcohol Use Disorders Identification (AUDIT) and social support with the Social Support Scale. Univariate and multivariate analyses were performed. Significance was set at p<0.05. Results: Seventy-one hypertensive patients were studied, with a mean age of 63.3±11 years; 53.5% men; 77.5% white; 77.1% with primary/secondary education; 53.5% retired; 52.1% income 2 minimum wages and non smokers; 19.7% sedentary; body mass index 30.8±5.8 kg/m2; 35.2% alcohol consumers, 43.7% adherent to treatment according to the Morisky and Green test and 32.4% with common non-psychotic mental disorders. On 19 out of 25 questions on the inhibiting factors of adherence form, scores for factors that least hampered treatment exceeded 90%. The highest agreement percentages were for: arriving for a consultation without the presence of a physician (36.6%), long waiting time for a consultation (16.9%) and not achieving blood pressure improvements (14.1%). Laboratory test results were: glucose- 121.3±43.6 mg/dL, total cholesterol 204.8±41.6 mg/dL, HDL-c- 48.5±11.25 mg/dL, VLDL-c- 29.5±15.2 mg/dL, LDL-c- 123.6±39.2 mg/dL, triglycerides- 150.1±88 mg/dL, urea- 45.1±16.4 mg/dL and creatinine- 1.0±0.5 mg/dL. A significant decrease (p<0.05) in blood pressure occurred between initial and final HBPM in the morning (144.9±15.7/85.8±9.4 vs 140.6±16.8/ 83.5±9.6 mmHg) and night period (145.7±18.0/84.5±9.9 vs 141.7±17.5/81.8±9.3 mmHg), as well as in the total average (145.1±16.2/85.0±9.4 vs 141.1±16.4/82.6±9.1 mmH). In home pressure measurement, a significant decrease in systolic pressure also occurred when comparing the first and eight week, measured in the morning (144.4±17.3/86.8±18.8 vs. 139.3±15.9/82.7±10.1 mmHg) and at night (144.7±19.8/83.2±10.5 vs. 140.8±17.8/82.2±10.4 mmHg), and also in the total average (144.4±17.6/85.1±12.2 vs. 140.2±16.2/83.4±9.3 mmHg). A significant decrease (p<0.05) also occurred in the outpatient measurement between the start and end of the study (157.6±13.6/91.4±8.3 vs. 146.9±19.9/85.1±11.5 mmHg). Thus, the decrease in the percentage of controlled hypertensive patients corresponded to: 67.6% and 57.7% in HBPM and 73.2% and 70.4% in outpatient measurement for systolic and diastolic pressure, respectively. Multivariate analysis showed that blood pressure control was associated with the following blood pressure assessments: a) systolic pressure measured at home with Morisky and Green test (OR: 0.187; CI 95%; 0.57-0.619) and the personal beliefs domain in the inhibiting factors of adherence questionnaire (OR: 0.696; CI 95% 0.502-0.965); b) diastolic pressure measured at home with age between 55 and 65 years (OR: 0.138; CI 95%; 0.030-0.637), age over 65 years (OR: 0.216; CI 95%; 0.055-0.845) and doing physical exercise (OR: 0.179; CI 95%; 0.044-0.730); c) outpatient diastolic pressure measure with presence of common mental disorders (OR: 8.746; CI 95%; 2.243-34.103), HDL - cholesterol < 40 and 40-59 mg/dL (OR: 3.644; CI 95%; 0.338-39.338) and HDL - cholesterol 60 mg/dL (OR: 37.323; CI 95%; 2.079-670.022); d) systolic and diastolic pressure in HBPM with institutional domain variable of inhibiting factors of adherence questionnaire (OR: 1.260; CI 95%; 1.036-1.533) and (OR: 1.212; CI 95%; 1.003-1464), respectively. Conclusion: The strategy to have patients measure their blood pressure at home was effect to increase blood pressure control in the group of hypertensive patients under analysis.
219

Efeito agudo do exercício aeróbio contínuo, intervalado e resistido na pressão arterial em idosas hipertensas / Acute effect of continuous aerobic exercise, interval and resistive on blood pressure in hypertensive elderly women

Campos, Giulliard de Oliveira 18 September 2017 (has links)
Objetivo: O presente estudo investigou as respostas hemodinâmicas agudas da pressão arterial sistólica (PAS), pressão arterial diastólica (PAD) e frequência cardíaca (FC), imediatamente e nas 24 horas após o exercício, em idosas hipertensas, submetidas a 3 tipos de exercícios físicos e um momento controle (C). Métodos: Participaram do estudo 30 idosas hipertensas sob terapia medicamentosa. Todas as idosas foram submetidas aos protocolos de exercício aeróbio contínuo (AC), exercício aeróbio intervalado (AI), exercício resistido (ER) e a (C), com o intervalo mínimo de 7 dias para assegurar o efeito agudo de cada intervenção, em ordem randomizada. Todas as participantes foram submetidas previamente ao teste ergométrico, utilizando-se o protocolo de rampa devido a sua melhor acurácia para a população em estudo. A prescrição do AC e do AI foi feita por meio da frequência cardíaca máxima (FCM) obtida no teste. Na intervenção do AC foi calculada a frequência cardíaca de treinamento (FCT), com a intensidade de 70% FCM, com duração de 40 minutos de exercício. No AI foi utilizado a alternância de 80% da FCM no período de condicionamento, durante 2 minutos, e 60% da FCM, durante 2 minutos, para o período de recuperação, com duração de 40 minutos de exercício. O ER foi conduzido após obtenção de uma repetição máxima (1RM) em três exercícios para os principais grupos musculares: chest press, leg press e remada sentada e mais seis exercícios resistidos comumente utilizados para a prescrição do treinamento de força nas academias, utilizando o número de repetições adequadas por meio da escala de percepção subjetiva de esforço (PSE). A intensidade do ER foi de 50% de 1RM para dez repetições para o aquecimento específico e, após 1 minuto, a carga era ajustada para 70% de 1RM e realizava-se uma série entre 6 e 10 repetições para o condicionamento em todos os exercícios. Os valores da PAS, PAD e FC foram obtidos antes e após as sessões dos exercícios pelo método oscilométrico e, após cada sessão era realizada a monitorização ambulatorial da pressão arterial (MAPA) de 24 horas nos 4 momentos. Os dados foram avaliados pelo modelo de efeitos mistos. Resultados: Os dados obtidos no período pré e pós exercícios, mostraram redução em menor valor da variável PAS após a realização do AI e AC comparados ao ER no momento pós exercício (p<0,01). Na FC foi observado aumento no período pós exercício em AI e AC em comparação com ER e de ER em relação ao C (p<0,01). As observações nas 24 horas subsequentes foram obtidas por meio da MAPA, com maior redução da PAS em AI nas 24 horas do que nos outros grupos, sendo a redução da PAS em ER também maior do que em AC e C (p<0,01). Na PAD, a redução em AI e ER foram similares. Considerando apenas o período de vigília, a redução de PAS em AI foi superior aos outros grupos. No período de sono, AI e ER promoveram maiores reduções na PAS, com maior redução da variável PAD em ER (p<0,01). Conclusão: A prática de exercício físico intervalado e resistido promovem maior hipotensão pósexercício (HPE) ao longo das 24 horas subsequentes, em relação ao AC e C. O exercício aeróbio contínuo promove apenas redução da pressão arterial nas primeiras horas após o exercício. / Objective: The present study investigated the acute hemodynamic responses of systolic blood pressure (SBP), diastolic blood pressure (DBP) and heart rate (HR), immediately and within 24 hours after exercise, in hypertensive elderly women submitted to 3 types of physical exercise and control. Methods: Thirty hypertensive elderly women in drug therapy participated of the study. They all underwent to continuous aerobic exercise (CA), interval aerobic (IA), resistance exercise (RE) and control (C), with a minimum interval of 7 days, in random order. All participants were previously submitted to the treadmill stress test, using the ramp protocol due to its better accuracy for the study population. The prescription of the CA and the IA was done by maximum heart rate (MHR) obtained by the test. In the CA intervention, training heart rate (THR) was calculated, with the intensity of 70% MHR, with duration of 40 minutes of exercise. In the IA, we used 80% of the MHR during the conditioning period for 2 minutes and 60% of the MHR during 2 minutes for the recovery period, lasting 40 minutes. The ER was conducted after obtaining a maximal repetition (1RM) in three exercises for the main muscle groups: chest press, leg press and seated paddling, and six more commonly used resistance exercises for the prescription of strength training in the academies, using the number of adequate repetitions through the subjective perception of effort scale (PES). The RE intensity was 50% of 1RM for ten replicates for the specific heating and after 1 minute the load was adjusted to 70% of 1RM, and a range of 6 to 10 replicates were performed for the conditioning. The SBP, DBP and HR values were obtained before and after the exercise sessions by the oscillometric method and after that, 24-hour ambulatory blood pressure monitoring (ABPM) was performed in the 4 moments. The data were evaluated by the mixed effects model. Results: Data obtained in the pre and post exercise period showed a decrease in the SBP variable after IA and CA compared to the RE (p <0.01). In the HR, we observed increase in the post-exercise period in IA and CA compared to RE and RE in relation to C (p <0.01). The observations in the subsequent 24 hours were obtained through ABPM, with a greater fall in SBP in IA in 24 hours than in the other groups, with a decrease in RE also greater than in CA and C (p <0.01). In DBP, IA and RE fall were similar. Considering only the waking period, the SBP decrease in IA was higher than the other groups. In the sleep period, IA and RE promoted fall in SBP, with a greater fall in DBP in RE (p <0.01). Conclusion: The practice of interval aerobic and resistance exercise promoted greater post-exercise hypotension (PEH) during the subsequent 24 hours, compared to CA and C. Continuous aerobic exercise promotes only drop in the first hours after exercise.
220

Estudo de grandezas dosimétricas aplicadas em pacientes submetidos a exames de tórax rotina em tomografia computadorizada / Study of dosimetric quantities applied to patient undergoing routine chest examinations by computed tomography

Natália Barbosa Gonzaga 01 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O sistema de proteção radiológica estabeleceu um padrão para proteger as pessoas contra os efeitos danosos causados pela radiação ionizante tendo por base os princípios da justificação, otimização e limitação de dose. O aumento do uso das radiações em medicina e, consequentemente, dos riscos associados, promoveu a discussão sobre a proteção de pacientes. A tomografia computadorizada (TC) é uma das técnicas em radiodiagnósticos que mais contribui com a exposição do paciente e que requer esforços de otimização. Níveis de referência em radiodiagnóstico (NRD) em termos de grandezas dosimétricas foram estabelecidas em muitos países; no Brasil, os NRD ainda estão em fase de investigação, já que a cultura de proteção de pacientes ainda não é muito forte. O objetivo deste trabalho foi estudar as grandezas dosimétricas associadas à pacientes submetidos a exames de tórax rotina por TC, que são o índice de kerma no ar ponderado (CW) e volumétrico (CVOL), o produto kerma no ar comprimento (PK,L), a dose equivalente em órgãos (HT) e a dose efetiva (E). Os programas computacionais ImPACT CT, CT Expo e ImpactDose, foram usados para cálculos das doses, relativas aos protocolos de exames de tórax rotina em 19 tomógrafos amostrados. O CT Expo foi selecionado e validado através de medidas experimentais em três tomógrafos com dosímetros termoluminescentes, câmara de ionização tipo lápis, objeto simulador antropomórfico físico e objeto simulador de tronco padrão. Os resultados experimentais e calculados indicaram diferenças de até 97% nos valores de HT e E e adequada concordância para CW, CVOL e PK,L. Os dados referentes aos 19 tomógrafos foram comparados com os NRD adotados em outros países e evidenciaram que os NRD locais para exames de tórax rotina em TC podem ser estabelecidos menores que àqueles, contribuindo para aumentar a proteção radiológica do paciente. / The radiological protection system has established a standard to protect persons against the harmful effects caused by ionizing radiation that is based on the justification, optimization and dose limitation principles. The increasing use of radiation in medicine and the related risks have stressed the discussion on patient radiation protection. The computed tomography (CT) is the diagnostic radiology technique that most contributes to patient doses and it requires optimization efforts. Diagnostic reference levels (DRL) has been established in many countries in terms of CT dosimetric quantities; in Brazil, the DRLs are still under investigation since the culture of patient protection is not very strong yet. The objective of this work was to investigate the dosimetric and protection quantities related to patients undergoing CT routine chest examinations. The ImPACT CT, CT Expo and ImpactDose softwares were used for calculations of the weight and volumetric air-kerma indexes (CW and CVOL), the air kerma length product (PK,L), organ equivalent dose (HT) and the effective dose (E) for CT routine chest protocols in 19 tomographs in Belo Horizonte city. The CT Expo was selected to be validated against experimental measurements in three hospitals with thermoluminescent dosimeters and CT pencil ionization chamber in anthropomorphic and standard CT body phantoms. Experimental and calculated results indicated differences up to 97% for HT and E and acceptable agreement for CW ,CVOL and PK,L. All data from 19 tomographs showed that local DRLs for CT routine chest examinations may be chosen smaller than DRLs adopted in other countries; this would contribute to increase the radiological protection of patients.

Page generated in 0.21 seconds