• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 18
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 327
  • 168
  • 87
  • 83
  • 82
  • 66
  • 63
  • 58
  • 57
  • 41
  • 39
  • 33
  • 30
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Determinantes das propriedades funcionais e estruturais das grandes artérias e as relações com lesões de órgãos-alvo em hipertensos estágio 3 / Determinants of functional and structural properties of large arteries and the correlations with end-organ damage in stage 3 hypertensive patients

Márcio Gonçalves de Sousa 09 October 2012 (has links)
As propriedades funcionais e estruturais das grandes artérias tem sido foco de atenção nos últimos anos para o melhor entendimento das alterações fisiopatológicas associadas à hipertensão arterial e ao envelhecimento. Muitas destas alterações como a rigidez arterial, tem sido consideradas marcadores independentes de risco cardiovascular. A avaliação destas propriedades não foi estudada em hipertensos mais graves, onde o risco de complicações é maior. O objetivo do estudo foi avaliar, em pacientes com hipertensão estágio 3, as alterações vasculares estruturais e funcionais em grandes artérias, seus principais determinantes e suas correlações com lesões de órgãos-alvo. Foram avaliados 48 pacientes (idade média 53,6 ± 8 anos; 75% brancos; 71% mulheres), com hipertensão arterial estágio 3, recebendo o mesmo tratamento anti-hipertensivo por um mês. A avaliação dos parâmetros carotídeos (diâmetro, espessura e distensão) foi realizada pelo ultrassom de radiofrequência e a rigidez arterial pela medida da velocidade de onda de pulso (VOP) e pelo Índice Ambulatorial de Rigidez Arterial (IARA). Realizamos ecocardiograma e perfil bioquímico para análise das variáveis e avaliação de lesão de órgãos-alvo. Foram realizadas correlações das variáveis bioquímicas, antropométricas e de lesões em órgãos-alvo com os métodos de avaliação vascular, além da correlação entre os métodos. Observamos uma elevada rigidez arterial tanto pela medida da VOP (12,4 m/s) quanto pelo IARA (0,39), e metade dos pacientes apresentou valores de VOP considerados de pior prognóstico (> 12 m/s). Houve correlação significativa do IARA com a medida da VOP. A distensão da carótida foi menor nos pacientes com diabetes. O principal determinante independente da VOP foi a idade e do IARA os níveis de glicemia. Observou-se correlação significativa e positiva entre a distensão de carótida e o índice de massa de ventrículo esquerdo. Em conclusão, pacientes com hipertensão estágio 3 apresentam alterações importantes das propriedades funcionais de grandes artérias, que são agravadas pelo envelhecimento e pela associação de diabetes, e uma delas está associada à hipertrofia ventricular esquerda presente nestes pacientes. / Functional and structural properties of large arteries have been matter of attention for the better understanding of physiopathological modifications associated to arterial hypertension and aging. Most of these alterations, as arterial stiffness, have been considered independent markers of cardiovascular risk. The evaluation of these properties has not yet been studied in severe hypertensives where the risk for complications is high. The aim of our study was to evaluate, in patients with stage 3 arterial hypertension, vascular changes of large arteries, its major determinants and the correlations with end-organ damage. We evaluated 48 patients (mean age 53,6 ± 8 years; 75% white; 71% women), with stage 3 arterial hypertension, under the same antihypertensive treatment for one month. Carotid parameters (diameter, wall thickness, distension) were evaluated by radiofrequency ultrasound and arterial stiffness by measurement of pulse wave velocity (PWV) and ambulatory arterial stiffness index (AASI). It was performed echocardiogram and biochemical profile to evaluation of other variables and end-organ damage. We did correlations among biochemical, anthropometrical variables and end-organ damage with vascular parameters. We observed increased arterial stiffness measured either by PWV values (12,4 m/s) or AASI (0,39), and half of patients had PWV values considered as a poor prognostic marker (> 12 m/s). It was observed a significant correlation between PWV and AASI. Carotid distension was lower in diabetic patients. The main independent determinant of PWV was age while glycemia was the main determinant of AASI. It was noticed a positive and significative correlation between carotid distension and left ventricle mass index. In conclusion, patients with stage 3 hypertension had important modifications of functional properties of large arteries that are impaired by aging and association of diabetes, and one of them is associated to left ventricle hypertrophy present in these patients
262

Monitorização residencial da pressão arterial (MRPA) no controle da pressão arterial de pacientes em hemodiálise / Home blood pressure monitoring (HBPM) in the blood pressure control in hemodialysis patients

Giovanio Vieira da Silva 25 August 2008 (has links)
INTRODUÇÃO: Não se sabe se o ajuste da terapia anti-hipertensiva baseado na Monitorização Residencial da Pressão Arterial (MRPA) pode melhorar o controle da pressão arterial em pacientes em hemodiálise. OBJETIVOS: Comparar a redução da pressão arterial (PA) e do índice de massa ventricular esquerda (IMVE) obtido com o uso da MRPA em relação às medidas da PA pré-diálise em pacientes em hemodiálise. MÉTODOS: Pacientes hipertensos em hemodiálise foram randomizados para ter a terapia anti-hipertensiva ajustada em dois grupos: controle, baseado na PA pré-diálise, e intervenção, baseada na MRPA. Antes e após 06 meses de acompanhamento, os pacientes realizaram Monitorização Ambulatorial da Pressão Arterial (MAPA) por 24 horas, MRPA durante uma semana e ecocardiograma transtorácico. RESULTADOS: 34 e 31 pacientes completaram o estudo no grupo intervenção e controle, respectivamente. As pressões arteriais sistólica (PAS) e diastólica (PAD) no período interdialítico pela MAPA foram significativamente menores no grupo intervenção em relação ao grupo controle no final do estudo (média 24 horas: 135 ± 13mmHg / 76 ± 7mmHg versus 147 ± 15mmHg / 79 ± 8mmHg, respectivamente - p<0,05). Na análise da MRPA, o grupo intervenção apresentou redução significativa somente para a PAS em comparação ao grupo controle (média semanal: 144 ± 21mmHg versus 154 ± 22 mmHg, respectivamente - p<0,05). Não houve diferenças entre os grupos intervenção e controle em relação ao IMVE ao final do estudo (108 ± 35 g/m2 versus 110 ±33 g/m2, respectivamente - p>0,05). CONCLUSÕES: O uso sistemático da MRPA no ajuste da terapia anti-hipertensiva em pacientes em hemodiálise propiciou maior controle da PA no período interdialítico em comparação às medidas da PA pré-diálise. A MRPA pode ser usada como um instrumento adjuvante útil no controle da pressão arterial em pacientes em hemodiálise / INTRODUCTION: It is not known whether the adjustment of the antihypertensive therapy based on Home Blood Pressure Monitoring (HBPM) can improve blood pressure (BP) control in hemodialysis patients. OBJECTIVES: To compare the reduction in BP and in the left ventricular mass index (LVMI) obtained with the use of HBPM in relation to that achieved with predialysis BP measurements in hemodialysis patients. METHODS: Hypertensive patients on hemodialysis were randomized to have the antihypertensive therapy adjusted according two groups: control, based on the predialysis BP measurements, and intervention, based on HBPM. Before and after 06 months of follow-up, patients were submitted to Ambulatory Blood Pressure Monitoring (ABPM) for 24 hours, HBPM during one week and transthoracic echocardiogram. RESULTS: 34 and 31 patients completed the study in the intervention and control groups, respectively. The systolic (SBP) and diastolic (DBP) blood pressure in the interdialytic period by ABPM were significantly lower in the intervention group compared with the control group at the end of the study (mean 24-hours BP: 135 ± 13 mm Hg / 76 ± 7 mmHg versus 147 ± 15 mm Hg / 79 ± 8 mmHg, respectively - p <0.05). When the interdialytic BP was analysed by HBPM, the intervention group showed significant reduction only for the PAS in comparison with control group (mean weekly BP: 144 ± 21 mm Hg versus 154 ± 22 mm Hg, respectively - p <0.05). There were no differences between intervention and control groups in relation to LVMI at the end of the study (108 ± 36 g/m2 versus 110 ± 33 g/m2, respectively - p> 0.05). CONCLUSIONS: The systematic use of HBPM in the adjustment of antihypertensive therapy in patients on hemodialysis has led to better control of BP during interdialytic period compared to that achieved with the predialysis BP measurements. The HBPM can be used as a useful adjunct instrument to control blood pressure in hemodialysis patients
263

Eficácia das tecnologias de suporte no tratamento cirúrgico dos gliomas insulares / Efficacy of assistive technologies in the surgical treatment of insular gliomas

Breno José Alencar Pires Barbosa 08 September 2016 (has links)
Introdução: No campo do tratamento cirúrgico de Gliomas, tem se observado um interesse crescente no uso de novas tecnologias de suporte como métodos auxiliares na obtenção do equilíbrio entre radicalidade cirúrgica e preservação da funcionalidade cerebral. Na maior parte dos estudos, a localização tumoral tem sido pouco considerada e a real eficácia das tecnologias de suporte ainda está pouco investigada nos gliomas insulares. Objetivos: avaliar a eficácia da fluorescência intraoperatória com 5-ALA, monitorização neurofisiológica, neuronavegação e tractografia no grau de ressecção tumoral (GRT), escores de funcionalidade, sobrevida global e sobrevida livre de progressão em uma coorte retrospectiva de gliomas insulares. Métodos: revisamos todos os casos de tumores insulares operados no Departamento de Neurocirurgia da Universidade de Tübingen - Alemanha, entre maio de 2008 e novembro de 2013. O grau de ressecção foi avaliado por volumetria. Foram utilizados os testes de Mann Whitney, Qui-quadrado e funções de Kaplan Meier para análise do efeito de cada tecnologia nos desfechos primários e secundários. Resultados: 28 casos - 18 homens (64%) e 10 mulheres (36%); idade média 52,5 anos (12 - 59) - foram inclusos para análise. Gliomas de alto grau corresponderam a 20 casos (71%), com 8 lesões de baixo grau (29%). As tecnologias mais utilizadas foram monitorização neurofisiológica (64%) e neuronavegação (68%). 5-ALA foi a única modalidade associada a taxas de ressecção > 90% (p = 0,05). O uso de tractografia determinou melhora no KPS (50% vs 5%, p = 0,02). Houve associação positiva entre o uso de neuronavegação e sobrevida global (23 vs. 27,4 meses, p = 0,03), mas o uso de 5-ALA se associou a piora na sobrevida global (34,8 vs 21,1 meses, p = 0,01) e sobrevida livre de progressão (24,4 vs. 11,8 meses, p = 0,01). Conclusões: Considerando os gliomas insulares, o presente trabalho demonstra pioneiramente que o uso de 5-ALA tem papel na obtenção de maiores taxas de ressecção, ainda que este achado possa estar associado a piora nas sobrevidas global e livre de progressão. Tractografia e neuronavegação parecem desempenhar papel importante no tratamento dos gliomas insulares, na medida em que determinaram melhor sobrevida global e funcionalidade, respectivamente. Estudos prospectivos com uma amostra mais proeminente e análise multivariada permitirão a avaliação do benefício real destas tecnologias de suporte no tratamento dos gliomas insulares / Introduction: In the field of Glioma surgery, there has been an increasing interest in the use of assistive technologies to overcome the difficulty of preserving brain function while improving surgical radicality. In most reports, tumor localization has seldom been considered a variable and the role of intraoperative adjuncts is yet to be determined for gliomas of the insula. Objectives: to evaluate the efficacy of fluorescence-guided resection with 5-ALA, intraoperative neurophysiological monitoring (IOM), neuronavigation, and tractography in the Extent of Resection (EOR), functionality scores, overall survival (OS) and progression-free survival (PFS) in a retrospective cohort of insular gliomas. Methods: we reviewed all cases of insular tumors operated on at the Department of Neurosurgery, University Hospital of Tübingen - Germany, between May 2008 and November 2013. EOR was determined by volumetric analysis. Mann Whitney, Chi-square and Kaplan Meier functions were used for assessment of each technology\'s effect on primary and secondary outcomes. Results: 28 cases (18 men (64%) and 10 women (36%); median age at diagnosis: 52.5 years, range 12 - 59) were considered eligible for analysis. High grade and low grade gliomas accounted for 20 (71%) and 8 (29%) cases, respectively. The most used technologies were IOM (64%) and Neuronavigation (68%). 5-ALA was the only technique associated with EOR > 90% (p = 0.05). Tractography determined improvement in the Karnofsky Performance Scale (50% vs 5% cases improved, p = 0.02). There was a positive association between the use of neuronavigation and overall survival (23 vs. 27.4 months, p = 0.03), but the use of 5-ALA was associated with shorter OS (34.8 vs. 21.1 months, p = 0.01) and PFS (24.4 vs. 11.8, p = 0.01). Conclusions: we demonstrate for the first time that for insular gliomas 5-ALA plays a role in achieving higher EOR, although this technology was associated with poor OS and PFS; Also tractography and neuronavigation can be of great importance in the treatment of insular gliomas as they determined better functionality and overall survival in this study, respectively. Prospective studies with a more prominent sample and proper multivariate analysis will help determine the real benefit of these adjuncts in the setting of insular gliomas
264

Critérios eletrofisiológicos de prognóstico da função facial baseados no pontencial evocado motor do nervo facial intraoperatório durante os diversos tempos cirúrgicos da cirurgia do schwannoma vestibular / Electrophysiological parameters of facial motor evoked potential predict postoperative facial function during vestibular schwannoma resection

Marcus André Acioly de Sousa 26 October 2011 (has links)
O potencial evocado motor facial (PEMF) tem-se mostrado um excelente método de monitorização do nervo facial, gerando resultados bastante confiáveis e reprodutíveis no que tange à predição da função facial pós-operatória. O critério eletrofisiológico mais utilizado até então para tanto tem sido a relação de amplitude do PEMF final-valor de base. Os objetivos deste trabalho foram avaliar as alterações intraoperatórias da amplitude e da complexidade do PEMF, correlacioná-las com o prognóstico facial no pós-operatório imediato e tardio e verificar se amplitude e complexidade constituem variáveis independentes de predição funcional. Os registros dos potenciais intraoperatórios dos músculos orbiculares do olho e da boca de 35 pacientes portadores de schwannoma vestibular (SV) foram coletados e analisados retrospectivamente de acordo com tempos cirúrgicos preestabelecidos: inicial, abertura da dura-máter, dissecação do tumor (TuDis), ressecção do tumor (TuRes) e final. No pós-operatório imediato, a função facial apresentou uma significativa correlação negativa com as relações de amplitude do PEMF durante a TuDis, a TuRes e ao final do procedimento nos músculos orbiculares do olho (p =0,003, 0,055 e 0,028, respectivamente) e da boca (p=0,002, 0,104 e 0,014, respectivamente). No último seguimento, entretanto, a correlação foi significativa apenas para o músculo orbicular da boca, durante a TuDis (p=0,005) e ao final do procedimento (p=0,102). As variações da complexidade dos potenciais alcançaram resultados mais significativos tanto no pós-operatório imediato, quanto no tardio, de forma que houve uma correlação negativa no músculo orbicular do olho apenas nas medidas finais (imediato, p=0;023; seguimento, p=0,116) e no músculo orbicular da boca durante a TuDis, a TuRes e a medida final (imediato, p=0,071, 0,000 e 0,001, respectivamente; seguimento, p=0,015, 0,001 e 0,01, respectivamente). As alterações intraoperatórias das relações de amplitude e de complexidade dos PEMFs parecem representar variáveis independentes, podendo ser utilizadas na predição da função facial pós-operatória durante cirurgias de ressecção de SV. Baseados nos resultados deste trabalho, a monitorização evento-valor de base é bastante útil, justificando mudanças imediatas da estratégia cirúrgica, com o intuito de reduzir as chances de uma lesão definitiva do nervo facial. / Facial motor evoked potential (FMEP) amplitude ratio reduction at the end of the surgery has been identified as a good predictor for postoperative facial nerve outcome. We sought to investigate variations in FMEP amplitude and waveform morphology during vestibular schwannoma (VS) resection and to correlate these measures with postoperative facial function immediately after surgery and at the last follow-up. Besides we analyzed the relationship between quantitative parameters. Intraoperative orbicularis oculi and oris muscles FMEP data from 35 patients undergoing surgery for VS resection were collected, then analyzed by surgical stage: initial, dural opening, tumor dissection (TuDis), tumor resection (TuRes) and final. Immediately after surgery, postoperative facial function correlated significantly with the FMEP amplitude ratio during TuDis, TuRes and final in both the orbicularis oculi (p´s=0.003, 0.055 and 0.028, respectively) and oris muscles (p´s=0.002, 0.104 and 0.014, respectively). At the last follow-up, however, facial function correlated significantly with the FMEP amplitude ratio only during TuDis (p=0.005) and final (p=0.102) for the orbicularis oris muscle. At both time points, postoperative facial paresis correlated significantly with FMEP waveform deterioration in orbicularis oculi during final (immediate, p=0.023; follow-up, p=0.116) and in orbicularis oris during TuDis, TuRes and final (immediate, p´s=0.071, 0.000 and 0.001, respectively; follow-up, p´s=0.015, 0.001 and 0.01, respectively). FMEP amplitude ratio and waveform morphology during VS resection seem to represent independent quantitative parameters that can be used to predict postoperative facial function. Event-to-baseline FMEP monitoring is quite useful to dictate when intraoperative changes in surgical strategy are warranted to reduce chances of facial nerve injury.
265

"Monitorização ambulatorial da pressão arterial de pacientes com oclusão do ramo da veia central da retina" / Blood pressure monitoring of branch retinal vein occlusion patients

Alexandre Antonio Marques Rosa 24 November 2005 (has links)
Avaliou-se a prevalência de hipertensão arterial sistêmica (HAS) e a variação circadiana da pressão arterial (PA), através da Monitorização ambulatorial da pressão arterial (MAPA), em pacientes com oclusão do ramo da veia central da retina (ORVCR). Foram avaliados, prospectivamente, 93 casos/olhos de 83 pacientes. A ausência do descenso fisiológico da PA durante o sono ("non-dipper") foi definida como diminuição da pressão sistólica = 10% e a presença de descenso quando este valor fosse maior ("dipper"). Há uma prevalência extremamente alta (94%) de HAS em pacientes com ORVCR. Entre os hipertensos, uma grande parcela dos indivíduos "non-dipper" (n=34; 44,2%). Estas evidências sugerem que um nível mais sustentado de PA nas 24 horas possa ser um fator de risco para o desenvolvimento da ORVCR / Objective: Identifying with Blood pressure monitoring (BPM) in patients with branch retinal vein occlusion (BRVO): high blood pressure (HBP) prevalence, possible cases of white-coat normotension (WCNT) and variation of circadian blood pressure (BP). Methods: Prospectively, 93 cases/eyes of 83 patients with BRVO were evaluated at Ophthalmological Clinic of "Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo" (HCFMUSP). After that, patients were taken to Hypertension League of Nephrology Chair of HCFMUSP (LH-HCFMUSP) for clinical evaluation and blood pressure monitoring. Non-dipper was defined as a fall in systolic blood pressure = 10%, and dipper when this value was higher
266

Avaliação da pressão arterial antes e após paratireoidectomia por hiperparatireoidismo primário / Arterial blood pressure monitoring before and after parathyroidectomy for primary hyperaparathyroidism

Ledo Mazzei Massoni Neto 13 March 2018 (has links)
INTRODUÇÃO: O hiperparatireoidismo primário (HPTP) é uma doença endócrina cuja prevalência aumentou muito nas últimas décadas. Descobriu-se grande contingente de portadores de formas leves e assintomáticos. Foi observado que esses pacientes apresentam alta morbidade e mortalidade por causas cardiovasculares. O estudo da pressão arterial revelou alta incidência de hipertensão arterial e descenso atenuado. A reversibilidade destes efeitos após a paratireoidectomia, entretanto é controversa. MÉTODO: Estudo prospectivo observacional com pacientes portadores de HPTP esporádico submetidos a paratireoidectomia para verificar as alterações dos parâmetros relativos à pressão arterial após a resolução do HPTP. Os pacientes realizaram monitorização ambulatorial de 24 horas da pressão arterial antes e após cirurgia curativa para HPTP, no 3º pós-operatório, 3 meses, 6 meses e 12 meses. RESULTADOS: Em 7 casos (6 mulheres, idade média 65,7 anos), houve aumento do descenso da pressão arterial sistólica e diastólica. As médias (desvio padrão) da pressão arterial sistólica (PAS) e da pressão arterial diastólica (PAD) foram 124,0mmHg (10,6) e 78,7mmHg (10,4). Não foi observada alteração significativa após a operação. As médias de PAS foram 129,4 mmHg (3 PO), 130,4 mmHg (3 meses) 125,4 mmHg(6 meses) e 131,1 mmHg (12 meses). As médias de PAD foram 73,7 mmHg (3 PO), 78,6 mmHg 75,4 mmHg (6 meses) e 78,0 MMhg (12 meses). Por outro lado, o descenso noturno sistólico e diastólico da pressão arterial apresentaram melhora significativa aos 6 meses e sustentada aos 12 meses. As médias do descenso da PAS foram de 4,3% no pré-operatório; 1,2% no 3o pós-operatório; 10,7% após 6 meses (p=0,002) e de 10,5% 12 meses depois da operação (p=0,008). As médias do descenso da PAD foram de 7,1% no pré-operatório, 4,0% no 3o pós-operatório, 13,3%; aos 6 meses (p=0,02) e de 14,7% depois de 12 meses da paratireoidectomia (p=0,03). CONCLUSÃO: A paratireoidectomia melhora o descenso noturno da pressão arterial em pacientes com HPTP esporádico / INTRODUCTION: Primary hyperparathyroidism is an endocrine disease and its prevalence has increased dramatically in the last decades. There is a great number of individuals with mild or asymptomatic forms of the disease. There is evidence of cardiovascular complications and mortality in these patients. The study of blood pressure showed high prevalence of hypertension and decreased dipping. The reversibility of these effects on blood pressure after curative parathyroidectomy is debatable. METHODS: Prospective study to evaluate the changes in blood pressure measurements of patients undergoing curative parathyroidectomy for sporadic PHPT with 24-hour ambulatory blood pressure monitoring before (PRE) and after curative surgery, during hospital stay (PO3), three months (3 mo), six months (6 mo) and at 12 months (12 mo). RESULTS: In 7 cases (6 female, mean age 65.7 years), there was an improvement of the nocturnal dipping of the systolic and diastolic arterial pressure. Mean (standard deviation) preoperative Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP) were 124.0 mmHg (10.6) and 78.7 mmHg (10.4). No significant change in blood pressure was observed after the operation. Mean SBP values were 129.4 mmHg (PO 3), 130.4 mmHg (3 mo), 125.4 mmHg (6 mo) and 131.1 mmHg (12 mo). Mean DBP measures were 73.7 mmHg (PO 3), 78.6 mmHg (3 mo), 75.4 mmHg (6 mo) and 78.0 mmHg (12 mo). Conversely, nocturnal systolic and diastolic dipping presented a small nonsignificant decrease immediately after the operation, but a statistically significant and sustained improvement at 6 months and 12 months. Mean systolic nocturnal dipping was 4.3% (PRE), 1.2% (PO 3); 10.7% (6 mo) (p=0,002) and 10.5% (12 mo) (p=0.008). Mean diastolic nocturnal dipping was 7.1% (PRE), 4.0% (PO 3), 13.3% (6 mo) (p=0,01) and 14.7% (12 mo) (p=0.03). Conclusions: In sporadic PHPT, parathyroidectomy improves nocturnal dipping of blood pressure
267

Estudo da monitorização contínua de glicose e das respostas de pressão arterial, frequência cardíaca e de outros parâmetros fisiológicos antes e após treinamento físico em diabéticos tipo II / Study of continuos glucose monitoring and responses in blood pressure, heart rate and others physiological parameters before and after physical training in type II diabetics

Daniele Albano Pinheiro 19 March 2014 (has links)
Há muitas alterações nos sistemas fisiológicos de indivíduos com diabetes melittus em função dos constantes momentos de hiperglicemia, principalmente alterações relacionadas ao aumento dos riscos cardiovasculares. O objetivo desse estudo foi avaliar as respostas do controle glicêmico pelo monitor contínuo de glicose e da pressão arterial (PA), frequência cardíaca (FC) e sua variabilidade expressa pelos valores de RMSSD em diabéticos tipo II submetidos a testes de avaliação antes e após a realização de treinamento aeróbio e resistido. Participaram desse estudo 9 voluntários diabéticos tipo II do sexo masculino (45 a 65 anos) divididos em 3 grupos: DTA (n=7), diabéticos submetidos a seis semanas de treinamento aeróbio; DTR (n=5), diabéticos submetidos a treinamento resistido e GDC (n=5), diabéticos sem qualquer treinamento regular. Os voluntários realizaram testes laboratoriais, ergoespirometria e teste de fadiga em leg press antes e após o treinamento físico. Os resultados foram analisados estatisticamente pelo teste t de Student e pelo teste de Kruskal Wallis. Os voluntários tiveram a cinética da concentração de glicose mensurada pelo monitor contínuo e analisada qualitativamente antes, durante e após a realização da ergoespirometria e do teste de fadiga por 60 minutos. Como resultados o grupo DTA apresentou menores valores de concentração de glicose pela monitorização contínua e o grupo DTR a melhor resposta na cinética dessa curva, apresentando expressivo decaimento na mesma. Em relação à resposta pressórica, somente a PA diastólica (PAD) foi menor estatisticamente para o grupo DTA pós treinamento aeróbio no repouso. Não houve diferenças entre os valores pré e pós treinamentos em relação à FC e os voluntários do grupo DTA apresentaram maiores valores de RMSSD em repouso e o do grupo DTR incrementos desses valores na recuperação dos testes, mostrando maior ação parassimpática no controle autonômico cardíaco dos diabéticos submetidos a treinamentos. Os indivíduos do grupo GDC apresentaram decremento nesse valor, sugerindo piora no controle autonômico cardíaco. Como conclusão geral, este estudo sugere que indivíduos diabéticos tipo II que realizaram treinamento aeróbio e resistido apresentaram benefícios complementares no controle glicêmico registrado pelo monitor contínuo em repouso e no período de recuperação de exercício, respectivamente, adaptações que parecem estar associadas à melhora da ação parassimpática/vagal no controle autonômico cardíaco e, sugere, também, ser o treinamento físico aeróbio o que permite melhor organização hemodinâmica nas respostas de PAD. / There are many changes in physiological systems of people with diabetes melittus due to the constant moments of hyperglycemia, mainly related to increasing of cardiovascular risk. The aim of this study was evaluate the responses of glycemic control by continuos glucose monitoring and blood pressure (BP), heart rate (HR) and its variability expressed by the values of RMSSD in type II diabetics undergoing evaluation tests before and after performing aerobic and resistance training. Participants were 9 volunteers type II diabetic male (45-64 years) divided in 3 groups: DTA (n=7), diabetics undergoing six weeks of aerobic training; DTR (n=5), diabetics undergoing resistance training and GDC (n=5), diabetics without any regular training. The volunteers underwent laboratory tests, spirometry and fatigue tests on leg press before and after physical training. The results were statistically analyzed by Students t and Kruskal Wallis tests. The volunteers had the kinetics of glucose concentration measured by the continuos monitor and qualitatively analyzed before, during and after the spirometry and the fatigue tests for 60 minutes. As a result the DTA group had lower glucose concentration by continuos monitoring and DTR the best response in the kinetic curve, showing important decrease in it. In relation to the BP response, only diastolic BP (DBP) was statistically lower for the DTA group after aerobic training. There were no differences between pre and post training in HR and the DTA group showed higher RMSSD at rest and the DTR group showed increments of these values in the tests recovery showing higher parasympathetic action on cardiac autonomic control in diabetics patients with training. Individuals in the GDC group showed decrement this value, suggesting deterioration in cardiac autonomic control. As a general conclusion, this study suggests that type II diabetic individuals who performed aerobic and resistance training showed additional benefits in glycemic control by continuos monitor recorded at rest and during exercise recovery, respectively, adaptations that seem to be associated with improvement in parasympathetic action in cardiac autonomic control, and also suggests that aerobic exercise training has better organization hemodynamic in responses of DBP.
268

Associação entre as variáveis da monitorização ambulatorial da pressão arterial e a ocorrência de eventos cardiovasculares em octogenários com hipertensão arterial controlada / Association between ambulatory monitoring blood pressure variables and occurrence of cardiovascular events among octogenarians with controlled arterial hypertension

Solange de Sousa Andrade 13 August 2009 (has links)
Introdução: Nos estudos sobre hipertensão em idosos, a população participante é predominantemente da faixa etária entre 60 e 79 anos enquanto aqueles mais de 80 anos pouco participam destes estudos. Nos ensaios clínicos, a monitorização ambulatorial da pressão arterial tem-se mostrado útil no acompanhamento clínico da hipertensão arterial, porém foi empregada indivíduos relativamente jovens e suas variáveis mostram valor preditivo maior para eventos cardiovasculares que a medida da pressão arterial no consultório Objetivo: avaliar hipertensos octogenários tratados com valores de pressão arterial no consultório iguais e inferiores à 140x90 mmHg e as variáveis obtidas pela MAPA e associá-las com a ocorrência de eventos cardiovasculares e cerebrovasculares. Métodos: participaram 126 octogenários hipertensos em tratamento nos últimos 3 meses e idade mediana de 83 anos. A pressão arterial no consultório foi verificada na posição sentada, supina e ortostática como também foram obtidos informações sobre comorbidades, fatores de risco cardiovasculares e medicações. Em seguida, os pacientes foram submetidos à MAPA. Esses idosos foram acompanhados no período de 23 ±5,6 meses em média e uma consulta a cada 6 meses a fim de obter informações da ocorrência de eventos cardiovasculares. Resultados: A população foi composta de 62,7% de mulheres e as doenças mais prevalentes foram a doença arterial coronariana (33,3%), o diabete melito (23,8%) e a insuficiência cardíaca (22,2%). Dentre os anti-hipertensivos, os mais utilizados foram o inibidores da enzima de conversão de angiotensina (62,7%), os diuréticos (57,9%) e os bloqueadores beta -adrenérgicos (41,3%). No consultório e na posição sentada, a média da pressão arterial foi de 130,9±9,2 mmHg x 73,3±8,9 mmHg. A hipotensão ortostática esteve presente em 31,7% dos idosos estudados. Na MAPA, a média da pressão arterial na vigília foi de 127,1±6,5 x 69,1±8,5 mmHg e durante o sono 122,8 ± 17,3 x 62,9 ± 10,4 mmHg. Para analisar as variáveis obtidas no consultório na MAPA associadas à eventos cardiovasculares, a amostra foi dividida em um grupo com e sem eventos. Durante o seguimento, ocorreram doze eventos cardiovasculares (6 coronarianos e 6 cerebrovasculares). No grupo com eventos, é significativamente maior a prevalência de AVC prévio (33.3% vs. 7.0%, p=0.016). Os fatores de risco cardiovasculares foram similares em ambos os grupos. Também, não houve diferença entre os grupos quanto às classes de anti-hipertensivos. Na análise multivariada, a carga pressórica sistólica diurna e acidente vascular cerebral prévio foram as variáveis independentes para a ocorrência de eventos cardiovasculares. Realizado um modelo de regressão logística ajustado com as variáveis AVC e carga pressórica sistólica na vigília com ponto de corte em 35% obteve-se as seguintes razão de chances (OR) e intervalos de confiança : AVC (OR: 7,669; IC: 1,629-36,098; p = 0,009) e carga pressórica sistólica na vigília (OR: 6,752; IC: 1,750; IC: 26,051; p = 0,005), sensibilidade de 66,7%, especificidade de 75,4%, valor preditivo negativo de 95,6% e acurácia de 74,6%. Conclusão: A carga pressórica sistólica diurna maior que 35% foi forte preditor de eventos cardiovasculares em octogenários hipertensos controlados, principalmente quando associado a AVC prévio / Introduction: In studies on hypertension among the elderly, the participating population is predominantly in the 60-79 year age group, while those over 80 account for an insignificant number in these studies. The evaluation of antihypertensive treatment effect has been based mainly on office BP. However, several studies have indicated that 24-hour ambulatory blood pressure monitoring (ABPM) is a better predictor of cardiovascular events than office blood pressure (BP). The objective of this study was to evaluate the variables obtained by AMBP and associate them with the occurrence of cardiovascular and cerebrovascular events among treated hypertensive octogenarians patients with blood pressure values in the office equal to or lower than 140x90 mmHg. Methods: We included 126 hypertensive elderly octogenarian (age 83.8±3.4 years) outpatients with stable antihypertensive drug treatment for at least 3 months in the office. Values of blood pressure were measured with the patient in the seated, supine and orthostatic positions as well as data about cardiovascular risk factors, comorbidities, and medications were collected. The patients were submitted to AMBP and were followed-up for an average period of 23 ±5.6 months to obtain information on the occurrence of cardiovascular events. Results: The population consisted of 62.7% women and the most prevalent diseases were coronary arterial disease (33.3%), diabetes mellitus (23.8%) and cardiac insufficiency (22.2%). Of the antihypertensive drugs, the most commonly used were angiotensin-converting enzyme inhibitors (62.7%), diuretics (57.9%) and beta-adrenergic blockers (41.3%). In the office, the average blood pressure in the seated position was 130.9±9.2 mmHg x 73.3±8.9 mmHg. Orthostatic hypotension was present in 31.7% of the elderly patients studied. In the AMBP, the average awake blood pressure was 127.1±6.5 x 69.1±8.5 mmHg, while the average during sleep was 122.8 ± 17.3 x 62.9 ± 10.4 mmHg. Twelve cardiovascular events occurred (6 coronary and 6 cerebrovascular). To analyze the variables obtained in the office and the AMBP variables associated with cardiovascular events, the sample was divided into one group with events and a group without. In the group with events, the prevalence of previous stroke was significantly higher (33.3% vs. 7.0%, p=0.016). The cardiovascular risk factors were similar in both groups. Also, there was no difference between the groups in relation to the classes of antihypertensive drugs. In the multivariate analysis, daytime systolic pressure load and previous stroke were the independent variables for the occurrence of cardiovascular events. A logistical regression model was carried out, adjusted with the stroke variables and daytime systolic pressure load and a cut-off point of 35%, the following odds ratios and confidence intervals were obtained: stroke (OR: 7.669; IC: 1.629-36.098; p = 0.009) and daytime systolic pressure load (OR: 6.752; IC: 1.750; IC: 26.051; p = 0.005), sensitivity 66.7%, specificity 75.4%, negative predictive value 95.6% and accuracy 74.6%. Conclusion: Daytime systolic pressure load higher than 35% was a strong predictor of cardiovascular events in controlled hypertensive octogenarians, particularly when associated with previous stroke
269

Desenvolvimento de cateter implantável de monitorização de pressão intracraniana

Rosario, Jeferson Cardoso do 18 January 2019 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2019-03-25T11:56:58Z No. of bitstreams: 1 Jeferson Cardoso do Rosario_.pdf: 3523684 bytes, checksum: 6d033c623e7ef74a93692efd6ca37e8e (MD5) / Made available in DSpace on 2019-03-25T11:56:58Z (GMT). No. of bitstreams: 1 Jeferson Cardoso do Rosario_.pdf: 3523684 bytes, checksum: 6d033c623e7ef74a93692efd6ca37e8e (MD5) Previous issue date: 2019-01-18 / Nenhuma / O traumatismo cranioencefálico (TCE) é atualmente a terceira maior causa de óbitos no âmbito mundial. Estudos recentes têm demonstrado que a monitorização de pressão intracraniana (PIC), como forma de cálculo da pressão de perfusão cerebral (PPC) é uma ferramenta importante para avaliação do fluxo sanguíneo cerebral (FSC), provocando sensível redução nas taxas de mortalidade. Além do TCE, outras patologias ou situações neurocirúrgicas tem utilizado a técnica de monitorização de PIC. A monitorização desse parâmetro foi proposta já na década de 50, onde um tubo com fluido em contato com o líquido cefalorraquidiano (LCR) era introduzido no espaço intracraniano e conectado a um transdutor de pressão externo. Com a evolução da indústria microeletrônica e dos sistemas microeletromecânicos, foi possível colocar os transdutores na ponta do cateter, permitindo uma monitorização menos invasiva, com menos riscos de infecções. Os cateteres atuais com micro transdutor na ponta podem ser divididos em três grupo: straingauge, fibra óptica e pneumático. Cada grupo possui suas características, entretanto o primeiro tem se demonstrado como solução mais robusta e confiável, com boa relação custo benefício. No presente trabalho foi proposto o desenvolvimento de um cateter implantável de monitorização de pressão intracraniana do tipo micro transdutor strain-gauge. Foram construídos protótipos funcionais e submetidos a ensaios de desempenho, especificados em norma técnica para monitorização de pressão sanguínea, a influência da temperatura na medição de pressão, bem como a exatidão das medições. Os processos empregados no trabalho são utilizados comumente na indústria de encapsulamento de semicondutores, porém foram levadas em consideração as especificidades da aplicação, adequando as técnicas disponíveis às geometrias e materiais empregados, considerando a necessidade de utilização de materiais biocompatíveis. / The traumatic brain injury (TBI) is nowadays the third cause of death in the world. Recent studies have shown the intracranial pressure (ICP) monitoring as an important tool for cerebral perfusion pressure (CPP) calculation and cerebral blood flow (CBF) assestment, reducing significantly the mortality statistics. Besides TBI, several others pathologies and neurosurgery conditions have been using the ICP monitoring technique. The proposal of ICP monitoring first appeared on the 50’s, where a tube fulfilled with fluid in contact with cerebrospinal fluid (CSF) was introduced into the intracranial space and connected to an external pressure transducer. With the waves of the microelectronics and microelectromechanical systems (MEMS) industry evolution, it was possible to put the transducer and all the electronics inside the catheter tip, allowing a less invasive monitoring, decreasing the risk of infection. The state of art catheters with micro transducer on the tip can be divided into three groups: strain-gauge, optical fiber and pneumatic. Each group has it’s own characteristics, however the first has been demonstrated as the rugged solution, being reliable, cost effective and with good accuracy. In the present work, it was proposed the development of an strain-gauge micro transducer implantable catheter for intracranial pressure monitoring. Functional prototypes were built and submitted to performance tests, according to the technical standards in the medical equipment area, the temperature influence over the pressure measurements was evaluated, as well as the accuracy. The adopted processes are commonly used in the semiconductor packaging industry, however it was considered the application special requirements, adapting the processes to the geometry and materials used, considering the needs of biocompatible materials.
270

Avaliação intra-operatória da pressão portal e resultados do tratamento cirúrgico da hipertensão portal em pacientes esquistossomóticos / Intraoperative evaluation of the portal pressure and the immediate results of the surgical treatment of the portal hypertension in patients with schistosomiasis

Silva Neto, Walter de Biase da 21 October 2003 (has links)
No Brasil a principal causa de hipertensão portal é a esquistossomose mansônica na sua forma hepato-esplênica, classificada como pré-sinusoidal. Esta doença adquire grande importância epidemiológica, por acometer indivíduos jovens, com função hepática preservada, e por atingir uma grande parcela da população (cerca de 1 milhão de indivíduos). Destes, cerca de 12 a 52% irão apresentar hemorragia digestiva por ruptura de varizes de esôfago. Não existe até o momento nenhum tratamento que se estabeleça como de consenso para esta enfermidade, porém há uma preferência dos autores para o tratamento cirúrgico e, no Brasil, esta recai sobre a desconexão ázigo-portal e esplenectomia geralmente associada a escleroterapia endoscópica das varizes no pós-operatório. Não estão bem estabelecidas as alterações hemodinâmicas portais decorrentes do tratamento cirúrgico da hipertensão portal e sua influência no resultado deste tratamento. Com o objetivo de avaliar o impacto imediato da desconexão ázigo-portal e esplenectomia (DAPE) na pressão portal e os resultados do tratamento cirúrgico da hipertensão portal no que se refere à recidiva hemorrágica e ao calibre das varizes de esôfago, foram estudados 19 pacientes portadores de esquistossomose hepato-esplênica e hipertensão portal com história de hemorragia digestiva alta por ruptura de varizes esofágicas, com idade média de 37,9 anos. Durante a cirurgia foi avaliada a pressão portal, no início e no final do procedimento através da cateterização da veia porta por cateter de polietileno introduzido por veia jejunal. Todos os pacientes foram submetidos à endoscopia no pré e pós-operatório para avaliar a variação do calibre das varizes esofágicas. Os pacientes foram acompanhados ambulatorialmente e o tempo médio de seguimento foi de 26 meses. Como resultado obteve-se uma queda na pressão portal média de 31,3% após a DAPE (p=0,0001). No acompanhamento pós-operatório houve redução significativa do calibre das varizes esofágicas quando comparadas com a avaliação pré-operatória (p < 0,05). Apenas um paciente (8,3%) apresentou, durante o acompanhamento, recidiva hemorrágica porém, esta foi decorrente de úlcera gástrica e não de varizes esofágicas. Por fim chegou-se à conclusão de que a desconexão ázigo-portal e esplenectomia promoveu queda imediata na pressão portal, com conseqüente diminuição do calibre das varizes esofágicas, tendo sido eficaz no tratamento da hipertensão portal destes pacientes / The main cause of portal hypertension in Brazil is the hepato-splenic form of mansonic schistosomiasis, which is classified as pre-sinusoidal. It acquires major epidemiological importance because it occurs in young individuals and affects a huge parcel of the population (around 1 million people), 12 to 52% of whom will present digestive hemorrhage due to rupture of esophageal varices. There is no consensus treatment for this disease up to the moment, but there is a predilection for the surgical approach. In Brazil, the most employed technique is the esophagogastric devascularization with splenectomy (EGDS), generally associated to late postoperative endoscopical sclerotherapy of the esophageal varices. The hemodynamic alterations in the portal flow resulting from the surgery and their possible influences on the outcome are not well established. With the aim of evaluating the immediate impact of the EGDS upon the portal pressure as well as the results of the surgical treatment on the digestive hemorrhage recurrence and the caliber of the esophageal varices, 19 patients (11males, aged between 18 and 61 years) with hepato-splenic schistosomiasis, presenting portal hypertension and previous episodes of digestive hemorrhage were studied. None of the patients had received any treatment prior to the surgery. The portal pressure was assessed at the beginning and the end of the EGDS through catheterization of the portal vein with a polyethylene catheter introduced through a branch of a jejunal vein. All the patients were submitted to digestive endoscopy before and after the surgery (2 months), in order to classify the caliber of the esophageal varices according to Palmer\'s classification. They also entered the continuous program of endoscopical evaluation and sclerotherapy. The mean clinical follow up period was 26 months. Our results showed that the portal pressure had diminished in all the patients, with a mean decrease of 31.3% after the EGDS. In the postoperative follow up (1 month), the esophageal varices showed a statistically significant reduction in their calibers, when compared to the pre-surgical measurements (p=0.004). Only one patient presented digestive hemorrhage during the follow up period, but it was due to gastric ulcer and not to rupture of esophageal varices. These results have demonstrated that the EGDS promotes an immediate decrease in the portal pressure and a reduction in the caliber of the esophageal varices, thus contributing to the good results of this technique. With the association of EGDS and sclerotherapy of the esophageal varices, no hemorrhagic episodes were observed in this series, during the study

Page generated in 0.0526 seconds