• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 19
  • 1
  • 1
  • Tagged with
  • 42
  • 19
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo da interação solo-muro em concreto convencional, com resíduo de construção e demolição (RCD) e alvenaria de pedra / Study of the interaction soil-wall in conventional concrete, with residue of construction and demolition (RCD) and rock

Wallace Borges de Sá 28 March 2006 (has links)
Um dos principais problemas, na Região Metropolitana do Recife (RMR), nas encostas, é a ocupação antrópica desordenada, aumentando o número de moradias em áreas de risco. Uma das soluções para a estabilização das encostas é o uso da construção de estrutura de contenção como muro de arrimo. O ângulo de atrito solo-muro é um parâmetro fundamental para o dimensionamento. O seu valor é utilizado na avaliação dos empuxos ativo e passivo na análise de estabilidade do muro. A prática atual de projetos considera o valor do ângulo de atrito solo-muro como sendo igual ao ângulo de atrito do solo, uma parcela dele ou mesmo nulo a depender do caso. Valores experimentais para solos brasileiros não estão disponíveis na literatura. Desta forma, os projetos de muros de arrimo podem estar sendo dimensionados contra a segurança ou de forma antieconômica. Neste contexto na presente dissertação, foram realizados ensaios de cisalhamento direto em corpos de prova de solo e de outro material representativo de muros de arrimo (concreto convencional, concreto com agregado de resíduos de construção e demolição - RCD e rocha), com o objetivo de obter os ângulos de atrito interno do solo e do contato solomuro. Foram utilizados dois solos das encostas do Recife um arenoso (Ibura) e outro argiloso (Nova Descoberta). Foram avaliadas as rugosidades das superfícies em contato com os solos, para analisar sua influência na interação solo-muro. Os resultados obtidos são comparados com valores sugeridos na literatura, considerando a influência do solo e da rugosidade da superfície de contato. A relação entre o ângulo de atrito solo-muro e o ângulo de atrito do solo (ä/ö) varia de 3/4 a 1, com a Rugosidade Média, para o solo arenoso do Ibura e de 1/3 a 3/4 para o solo argiloso de Nova Descoberta. No solo arenoso, o atrito solo-muro tem menor influência da rugosidade da superfície de contato e tem valor muito próximo do ângulo de atrito interno do solo. No solo argiloso o atrito solo-muro é fortemente influenciado pela rugosidade da superfície de contato, e o seu valor varia de 1/3 a 3/4 do ângulo de atrito do solo / One of the main problems, in the Region Metropolitan of Recife (RMR), in the hillsides it is the disordered occupation, increasing the number of housings in risk areas. One of the solutions for the stabilization of the hillsides is the use of the construction of retained structure as support wall. The friction angle soil-wall is a basic parameter for the design of a support wall. Its value is used in the evaluation of the pushes active and passive in the analysis of stability of the wall. Practical the current one of projects in Brazil considers the value of the friction angle soil-wall as being equal to the angle of friction of the soil, a parcel of it or same zero to depend on the case. The values found in literature also indicate as estimative for this angle values that vary of zero to the angle of friction of the soil. Experimental values for Brazilian soils are not available in literature. Of this form the projects of support walls can be being designed against the security or of uneconomical form. In this context in the present dissertation tests of direct shear in specimens of composites of soil and another representative material of support walls had been carried through (conventional concrete, concrete with recycled aggregate of RCD and rock), with the objective to get the friction angle soil-wall. Two soils of the hillsides of Recife had been used (sandy and a other clayey one). The roughness of the surfaces in contact with soil had been evaluated, to analyze its influence in the interaction soil-wall. The gotten results are compared with values suggested in literature, having considered the influence of the soil and the roughness of the contact surface. The relation enters the friction angle soil-wall and the angle of friction of the ground (ä/ö) varies of 3/4 the 1, with the average roughness for the soil sandy of the Ibura and of 1/3 the 3/4 for the soil clayey of Nova Descoberta. In the soil sandy, the friction soil-wall has minor influence of the roughness of the faying surface and has value very next to the angle of internal friction of the soil. In the soil clayey the friction soil-wall strong is influenced by the roughness of the faying surface, and its value varies of 1/3 the 3/4 of the angle of friction of the soil
22

Estudo da interação solo-muro em concreto convencional, com resíduo de construção e demolição (RCD) e alvenaria de pedra / Study of the interaction soil-wall in conventional concrete, with residue of construction and demolition (RCD) and rock

Sá, Wallace Borges de 28 March 2006 (has links)
Made available in DSpace on 2017-06-01T17:57:27Z (GMT). No. of bitstreams: 1 wallace de sa.pdf: 2263305 bytes, checksum: a0c0a930c5ab441157930460e793e9b6 (MD5) Previous issue date: 2006-03-28 / One of the main problems, in the Region Metropolitan of Recife (RMR), in the hillsides it is the disordered occupation, increasing the number of housings in risk areas. One of the solutions for the stabilization of the hillsides is the use of the construction of retained structure as support wall. The friction angle soil-wall is a basic parameter for the design of a support wall. Its value is used in the evaluation of the pushes active and passive in the analysis of stability of the wall. Practical the current one of projects in Brazil considers the value of the friction angle soil-wall as being equal to the angle of friction of the soil, a parcel of it or same zero to depend on the case. The values found in literature also indicate as estimative for this angle values that vary of zero to the angle of friction of the soil. Experimental values for Brazilian soils are not available in literature. Of this form the projects of support walls can be being designed against the security or of uneconomical form. In this context in the present dissertation tests of direct shear in specimens of composites of soil and another representative material of support walls had been carried through (conventional concrete, concrete with recycled aggregate of RCD and rock), with the objective to get the friction angle soil-wall. Two soils of the hillsides of Recife had been used (sandy and a other clayey one). The roughness of the surfaces in contact with soil had been evaluated, to analyze its influence in the interaction soil-wall. The gotten results are compared with values suggested in literature, having considered the influence of the soil and the roughness of the contact surface. The relation enters the friction angle soil-wall and the angle of friction of the ground (ä/ö) varies of 3/4 the 1, with the average roughness for the soil sandy of the Ibura and of 1/3 the 3/4 for the soil clayey of Nova Descoberta. In the soil sandy, the friction soil-wall has minor influence of the roughness of the faying surface and has value very next to the angle of internal friction of the soil. In the soil clayey the friction soil-wall strong is influenced by the roughness of the faying surface, and its value varies of 1/3 the 3/4 of the angle of friction of the soil / Um dos principais problemas, na Região Metropolitana do Recife (RMR), nas encostas, é a ocupação antrópica desordenada, aumentando o número de moradias em áreas de risco. Uma das soluções para a estabilização das encostas é o uso da construção de estrutura de contenção como muro de arrimo. O ângulo de atrito solo-muro é um parâmetro fundamental para o dimensionamento. O seu valor é utilizado na avaliação dos empuxos ativo e passivo na análise de estabilidade do muro. A prática atual de projetos considera o valor do ângulo de atrito solo-muro como sendo igual ao ângulo de atrito do solo, uma parcela dele ou mesmo nulo a depender do caso. Valores experimentais para solos brasileiros não estão disponíveis na literatura. Desta forma, os projetos de muros de arrimo podem estar sendo dimensionados contra a segurança ou de forma antieconômica. Neste contexto na presente dissertação, foram realizados ensaios de cisalhamento direto em corpos de prova de solo e de outro material representativo de muros de arrimo (concreto convencional, concreto com agregado de resíduos de construção e demolição - RCD e rocha), com o objetivo de obter os ângulos de atrito interno do solo e do contato solomuro. Foram utilizados dois solos das encostas do Recife um arenoso (Ibura) e outro argiloso (Nova Descoberta). Foram avaliadas as rugosidades das superfícies em contato com os solos, para analisar sua influência na interação solo-muro. Os resultados obtidos são comparados com valores sugeridos na literatura, considerando a influência do solo e da rugosidade da superfície de contato. A relação entre o ângulo de atrito solo-muro e o ângulo de atrito do solo (ä/ö) varia de 3/4 a 1, com a Rugosidade Média, para o solo arenoso do Ibura e de 1/3 a 3/4 para o solo argiloso de Nova Descoberta. No solo arenoso, o atrito solo-muro tem menor influência da rugosidade da superfície de contato e tem valor muito próximo do ângulo de atrito interno do solo. No solo argiloso o atrito solo-muro é fortemente influenciado pela rugosidade da superfície de contato, e o seu valor varia de 1/3 a 3/4 do ângulo de atrito do solo
23

Fenda e silêncio: escritas do muro em Eugénio de Andrade, Sophia de Mello Breyner Andresen e Jorge de Sena nos percursos da modernidade poética portuguesa / Poetics of the wall in Eugénio de Andrade, Sophia de Mello Breyner and Jorge de Sena

Araujo, Joana Souto Guimarães 26 February 2019 (has links)
A pesquisa consiste em aproximações às obras de Eugénio de Andrade, Sophia de Mello Breyner Andresen e Jorge de Sena mediante a leitura da imagem recorrente do muro em seus poemas. Está dividida em quatro partes e nove capítulos, que se distribuem entre o estudo de questões históricas e teóricas e a análise particular da produção de cada poeta. A perspectiva histórica inclui leituras específicas de autores portugueses modernos como Cesário Verde, Raul Brandão e Fernando Pessoa, que antecedem os nomes de Andrade, Andresen e Sena surgidos na cena literária dos anos 1940 no contexto dos Cadernos de poesia e do Neorrealismo. A abordagem teórica investiga as relações entre poesia e experiência desdobradas na complementaridade entre as noções de crise e resistência em articulações dialéticas que se leem em procedimentos poéticos diversos organizados pela imagem do muro. Essas diferentes organizações da imagética do muro encaminham as análises particulares de Andrade, Andresen e Sena, definindo complexos próprios, em cada caso, segundo as noções de natureza, paisagem e matéria. / This research focuses on the functions and the meanings of the iterant wall image in the poetic works of Eugénio de Andrade, Sophia de Mello Breyner Andresen and Jorge de Sena. The study is divided into four parts and nine chapters distributed among historical and theoretical questions and the analysis of each poetic work. The historical perspective includes the reading of modern Portuguese authors such as Cesário Verde, Raul Brandão and Fernando Pessoa, who prepare the passage for Andrade, Andresen and Sena in the literary scene of the 1940s, in the context of the Cadernos de poesia and \"Neorrealismo\". The theoretical approach investigates the relationship between poetry and experience unfolded in the complementary notions of crisis and resistance, considered in terms of dialectical articulations and poetic procedures organized by the imagery of the wall. These different organizations of the image of the wall direct the analyzes of Andrade\'s, Andresen\'s and Sena\'s work, which constituted complexes of their own according to the notions of nature, landscape and matter.
24

Impacto de dispositivos de sombreamento externos  e muro na ventilação natural e no desempenho térmico de uma habitação de interesse social térrea / Impact of external shading devices and wall on natural ventilation and thermal performance of a ground floor low-cost house

Castaño, Hector Fabian Marin 09 May 2017 (has links)
Uma importante estratégia de projeto para melhorar o desempenho térmico das edificações em climas quentes e úmidos é a adoção conjunta da ventilação natural e de dispositivos de sombreamento. Contudo, quando a ventilação natural é ocasionada pela ação dos ventos nas edificações, as pressões do vento nas envoltórias da edificação são alteradas com a presença de elementos externos próximos que mudam as características do fluxo incidente. Deste modo, o presente trabalho tem como objetivo avaliar os impactos na ventilação natural, e nas temperaturas internas do ar e/ou no conforto térmico de uma habitação térrea em um clima quente e úmido, a partir do uso de diferentes dispositivos de sombreamento externos e muro. Para isso, foram realizadas simulações computacionais no programa EnergyPlus através do módulo AirflowNetwork. Foram realizados ensaios em túnel de vento de Camada Limite Atmosférica (CLA) para a obtenção dos coeficientes de pressão (Cps). Os resultados apontaram impactos específicos a cada elemento estudado, no entanto o fenômeno mais frequente nos casos com dispositivos de sombreamento foi a redução dos efeitos de sobrepressão e sucção. Quanto aos seus impactos nas renovações de ar, estes provocaram uma diminuição do fluxo de ar e, consequentemente, o aumento da temperatura no período predominantemente noturno. Entretanto, foi observado um maior impacto na atenuação das temperaturas internas nos períodos diurnos, que prevaleceu sobre o aumento nos períodos de ventilação. Destacou-se, dentre os dispositivos de sombreamento estudados, as proteções tipo veneziana por proporcionarem um melhor desempenho térmico. Já os muros, dentre todos os elementos estudados, foram os que tiveram maior impacto nos Cps. Tal fenômeno significou a diminuição da taxa de renovação de ar dentre 50 e 75%. O impacto mais sobressalente nas temperaturas internas nestes casos foi o aumento destas no período noturno, limitando o potencial da ventilação natural para a remoção de calor da edificação / An important design strategy for improving the thermal performance of buildings in hot and humid climates is the adoption of natural ventilation strategies and shading devices combined. However, when natural ventilation is wind-driven, the wind pressures on the building envelope are altered by the presence of nearby external elements that change the incident flows characteristics. Thus, the present work aims to evaluate the impacts on natural ventilation, and the internal air temperatures and/or the thermal comfort of a single ground floor low-cost house in a hot and humid climate, considering the use of different external shading devices and walls. For such, computational simulations were performed in the EnergyPlus program using the AirflowNetwork module. Atmospheric Limit Wind (CLA) wind tunnel tests were performed to obtain pressure coefficients (Cps). The results indicated specific impacts to each element studied, however the most frequent phenomenon in cases with shading devices was the reduction of the effects of overpressure and suction. As for their impacts on air changes rate, they caused a decrease in airflow and, consequently, an increase in temperature predominantly in the nocturnal period. However, a greater impact was observed in the attenuation of internal temperatures in the daytime periods, which prevailed over the increase in ventilation periods., Among the shading devices studied, venetian type protections for providing better thermal performance were highlighted. Among all the elements studied, the walls had the greatest impact on the Cps. This phenomenon meant the reduction of the air changes rate between 50 and 75%. The most significant impact on internal temperatures in these cases was the their increase at night, limiting the potential of natural ventilation to the removal of heat from the building.
25

Peles grafitadas: uma poética do deslocamento

Santos, Williams Roberto Martins January 2006 (has links)
85f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-05T12:34:32Z No. of bitstreams: 1 willyamssantospt1seg.pdf: 723840 bytes, checksum: 45798b7ea614cf59bf68cfccfce67ea2 (MD5) / Approved for entry into archive by Lêda Costa(lmrcosta@ufba.br) on 2013-04-18T12:37:19Z (GMT) No. of bitstreams: 1 willyamssantospt1seg.pdf: 723840 bytes, checksum: 45798b7ea614cf59bf68cfccfce67ea2 (MD5) / Made available in DSpace on 2013-04-18T12:37:19Z (GMT). No. of bitstreams: 1 willyamssantospt1seg.pdf: 723840 bytes, checksum: 45798b7ea614cf59bf68cfccfce67ea2 (MD5) Previous issue date: 2006 / A presente dissertação, desenvolvida no Mestrado em Artes Visuais da Escola de Belas Artes da Universidade Federal da Bahia, na linha de Processos Criativos, aborda aspectos relacionados as apropriações de imagens grafitadas, encontradas nos muros da cidade de Salvador, como também os meios técnicos e operacionais para a sua remoção na qual são nomeadas de peles grafitadas. Em seguida são selecionadas e posteriormente deslocadas para o espaço interno da galeria, ressignificando-as como documentos visuais, que vão comentando e ampliando notícias, pautando os dias, disseminando uma teia polissêmica de significados. A investigação das imagens grafitadas no espaço público ocupa-se a dar procedimentos em gerar uma poética, baseando-se em aspectos plásticos e conceituais à partir de princípios formativos para a construção da obra, sustentados principalmente por conceitos de pensadores como Gaston Bachelard, Henri Bérgson, Merleau-Ponty e Didi-Huberman. / Salvador
26

Estudo paramétrico para um muro de gravidade submetido a carregamentos sísmicos. / Parametric Study for a gravity wall subjected to seismic loads.

Tatiana Galvão Kurz 18 November 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presente dissertação apresenta um estudo do comportamento de um muro de gravidade flexível submetido a carregamentos sísmicos. A influência do carregamento sísmico, e mais precisamente da variação da aceleração horizontal de pico é avaliada num estudo paramétrico, através da análise dos resultados obtidos para os deslocamentos e acelerações horizontais que ocorreram no paramento do muro de gravidade. Optou-se pela análise ao longo do tempo, introduzindo o carregamento sísmico ao modelo numérico do qual fazia parte o muro de gravidade através de 5 históricos temporais de acelerogramas horizontais normalizados em 0,05g, 0,10g, 0,15g, 0,20g e 0,25g. O evento sísmico de origem dos acelerogramas normalizados foi o terremoto ocorrido no Chile em 27 de fevereiro de 2010 e medido na estação em San Jose de Maipo, a 332,7km do epicentro do terremoto. Utiliza-se um software computacional aplicado à Geotecnia, o Plaxis, para a calibração de um modelo numérico em situação estática e posterior desenvolvimento das análises paramétricas em condições sísmicas. As análises realizadas para avaliação do comportamento do muro de gravidade em condição sísmica foram a verificação da influência da variação do acelerograma horizontal normalizada introduzido na base do modelo nos valores das acelerações e deslocamentos horizontais atuantes no muro e a verificação da influência do carregamento sísmico em comparação com a situação estática, comparando-se os valores dos deslocamentos horizontais obtidos na análise estática e nas análises dinâmicas. Os fatores que influenciam potencialmente nos resultados numéricos em condições sísmicas foram apresentados, destacando-se os aspectos relacionados à modelagem numérica em condição de sismo. Os modelos constitutivos oferecidos, a possibilidade de incorporação do carregamento sísmico na base do modelo e a possibilidade de consideração do amortecimento visco-elástico de Rayleigh nos materiais são as principais qualidades do Plaxis, utilizado na modelagem numérica. Avaliou-se positivamente a potencialidade do Plaxis, visto que o programa mostrou-se uma ferramenta capaz de simular o comportamento de muros de gravidade sujeitos a carregamentos sísmicos.
27

Estudo paramétrico para um muro de gravidade submetido a carregamentos sísmicos. / Parametric Study for a gravity wall subjected to seismic loads.

Tatiana Galvão Kurz 18 November 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presente dissertação apresenta um estudo do comportamento de um muro de gravidade flexível submetido a carregamentos sísmicos. A influência do carregamento sísmico, e mais precisamente da variação da aceleração horizontal de pico é avaliada num estudo paramétrico, através da análise dos resultados obtidos para os deslocamentos e acelerações horizontais que ocorreram no paramento do muro de gravidade. Optou-se pela análise ao longo do tempo, introduzindo o carregamento sísmico ao modelo numérico do qual fazia parte o muro de gravidade através de 5 históricos temporais de acelerogramas horizontais normalizados em 0,05g, 0,10g, 0,15g, 0,20g e 0,25g. O evento sísmico de origem dos acelerogramas normalizados foi o terremoto ocorrido no Chile em 27 de fevereiro de 2010 e medido na estação em San Jose de Maipo, a 332,7km do epicentro do terremoto. Utiliza-se um software computacional aplicado à Geotecnia, o Plaxis, para a calibração de um modelo numérico em situação estática e posterior desenvolvimento das análises paramétricas em condições sísmicas. As análises realizadas para avaliação do comportamento do muro de gravidade em condição sísmica foram a verificação da influência da variação do acelerograma horizontal normalizada introduzido na base do modelo nos valores das acelerações e deslocamentos horizontais atuantes no muro e a verificação da influência do carregamento sísmico em comparação com a situação estática, comparando-se os valores dos deslocamentos horizontais obtidos na análise estática e nas análises dinâmicas. Os fatores que influenciam potencialmente nos resultados numéricos em condições sísmicas foram apresentados, destacando-se os aspectos relacionados à modelagem numérica em condição de sismo. Os modelos constitutivos oferecidos, a possibilidade de incorporação do carregamento sísmico na base do modelo e a possibilidade de consideração do amortecimento visco-elástico de Rayleigh nos materiais são as principais qualidades do Plaxis, utilizado na modelagem numérica. Avaliou-se positivamente a potencialidade do Plaxis, visto que o programa mostrou-se uma ferramenta capaz de simular o comportamento de muros de gravidade sujeitos a carregamentos sísmicos.
28

Cálculo do empuxo ativo com determinação numérica da superfície freática / Calculation of active thrust with numerical determination of the phreatic surface

Santos Junior, Petrucio José dos, 1975- 16 August 2018 (has links)
Orientador: Pérsio Leister de Almeida Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-16T16:58:48Z (GMT). No. of bitstreams: 1 SantosJunior_PetrucioJosedos_M.pdf: 1818015 bytes, checksum: 92ab0f753dc226315fad2785fd0cd0bc (MD5) Previous issue date: 2010 / Resumo: A determinação do empuxo ativo através de métodos de equilíbrio limite, para análise de muros de contenção é prática comum na engenharia geotécnica, principalmente pela simplicidade analítica de sua obtenção. Porém, havendo a presença de uma superfície freática no solo arrimado tal determinação não apresenta resultado analítico, sendo então requerido um estudo numérico para obter um valor que auxilie com certa precisão nessa análise. Poucos trabalhos foram feitos sobre esse tema e ainda assim sua importância não deixa de ser relevante para a verificação das condições de estabilidade de estruturas de arrimo drenantes. Nesse trabalho é feita uma abordagem numérica através do Método dos Elementos de Contorno (MEC) para determinação da posição da superfície freática e posterior cálculo do empuxo ativo pelo Método de Coulomb considerando a influência dessa superfície. É implementado um programa de computador, cujo algoritmo de cálculo, baseado em MEC, apresenta a posição da freática, o valor da vazão total que chega ao sistema de drenagem e o empuxo ativo atuante sobre a estrutura de contenção / Abstract: The determination of active thrust in retaining wall analysis through limit equilibrium is a routine in geotechnical engineering, mostly due to analytic simplicity. However, when there is a phreatic surface in the retained soil, such determination does not present an analytic result. Then a numerical study is necessary to obtain a representative value of prore water pressures in the soil for the analysis. There are few technical publications about this theme, but its importance is recognized in drained retaining wall stability calculation. This work proposes a numerical approach using Boundary Element Method (BEM) to evaluate the position of phreatic surface and calculation of active thrust coefficient through Coulomb's method considering the influence of this position. A computer program, which calculation algorithm based on BEM is developed. It presents the results of the phreatic surface position, the total flow volume that arrives to the drainage system and the active thrust value / Mestrado / Geotecnia / Mestre em Engenharia Civil
29

Impacto de dispositivos de sombreamento externos  e muro na ventilação natural e no desempenho térmico de uma habitação de interesse social térrea / Impact of external shading devices and wall on natural ventilation and thermal performance of a ground floor low-cost house

Hector Fabian Marin Castaño 09 May 2017 (has links)
Uma importante estratégia de projeto para melhorar o desempenho térmico das edificações em climas quentes e úmidos é a adoção conjunta da ventilação natural e de dispositivos de sombreamento. Contudo, quando a ventilação natural é ocasionada pela ação dos ventos nas edificações, as pressões do vento nas envoltórias da edificação são alteradas com a presença de elementos externos próximos que mudam as características do fluxo incidente. Deste modo, o presente trabalho tem como objetivo avaliar os impactos na ventilação natural, e nas temperaturas internas do ar e/ou no conforto térmico de uma habitação térrea em um clima quente e úmido, a partir do uso de diferentes dispositivos de sombreamento externos e muro. Para isso, foram realizadas simulações computacionais no programa EnergyPlus através do módulo AirflowNetwork. Foram realizados ensaios em túnel de vento de Camada Limite Atmosférica (CLA) para a obtenção dos coeficientes de pressão (Cps). Os resultados apontaram impactos específicos a cada elemento estudado, no entanto o fenômeno mais frequente nos casos com dispositivos de sombreamento foi a redução dos efeitos de sobrepressão e sucção. Quanto aos seus impactos nas renovações de ar, estes provocaram uma diminuição do fluxo de ar e, consequentemente, o aumento da temperatura no período predominantemente noturno. Entretanto, foi observado um maior impacto na atenuação das temperaturas internas nos períodos diurnos, que prevaleceu sobre o aumento nos períodos de ventilação. Destacou-se, dentre os dispositivos de sombreamento estudados, as proteções tipo veneziana por proporcionarem um melhor desempenho térmico. Já os muros, dentre todos os elementos estudados, foram os que tiveram maior impacto nos Cps. Tal fenômeno significou a diminuição da taxa de renovação de ar dentre 50 e 75%. O impacto mais sobressalente nas temperaturas internas nestes casos foi o aumento destas no período noturno, limitando o potencial da ventilação natural para a remoção de calor da edificação / An important design strategy for improving the thermal performance of buildings in hot and humid climates is the adoption of natural ventilation strategies and shading devices combined. However, when natural ventilation is wind-driven, the wind pressures on the building envelope are altered by the presence of nearby external elements that change the incident flows characteristics. Thus, the present work aims to evaluate the impacts on natural ventilation, and the internal air temperatures and/or the thermal comfort of a single ground floor low-cost house in a hot and humid climate, considering the use of different external shading devices and walls. For such, computational simulations were performed in the EnergyPlus program using the AirflowNetwork module. Atmospheric Limit Wind (CLA) wind tunnel tests were performed to obtain pressure coefficients (Cps). The results indicated specific impacts to each element studied, however the most frequent phenomenon in cases with shading devices was the reduction of the effects of overpressure and suction. As for their impacts on air changes rate, they caused a decrease in airflow and, consequently, an increase in temperature predominantly in the nocturnal period. However, a greater impact was observed in the attenuation of internal temperatures in the daytime periods, which prevailed over the increase in ventilation periods., Among the shading devices studied, venetian type protections for providing better thermal performance were highlighted. Among all the elements studied, the walls had the greatest impact on the Cps. This phenomenon meant the reduction of the air changes rate between 50 and 75%. The most significant impact on internal temperatures in these cases was the their increase at night, limiting the potential of natural ventilation to the removal of heat from the building.
30

Propuesta de remediación geotécnica de un talud incorporando un muro de suelo reforzado con el sistema Terramesh para el proyecto de la carretera Matarani – El Arenal

Altamirano Reyna, Greta Lucia, Rivas Vera, Jaime Jonathan January 2015 (has links)
La presente investigación es de tipo descriptiva y explicativa, donde se propone una solución geotécnica para el reforzamiento de un talud aplicando el sistema terramesh, para lo cual se aplica un cálculo de estabilidad que determina factores de seguridad y superficies de falla del suelo, a su vez se obtendrá parámetros geotécnicos mediante ensayos de laboratorio. Se aplicará un método de estabilidad, siendo este el método de introducción de fuerzas resistentes del tipo terramesh. Asimismo utilizar el software MacStars 2000 como herramienta para el dimensionamiento y diseño del muro de suelo reforzado tipo terramesh para ser aplicado en el talud de la carretera, el cual tendrá un mínimo impacto ambiental, devolviendo la comunicación y servicialidad de la vía para los pueblos aledaños. Finalmente determinar las ventajas y desventajas que proporciona la solución. The present research is descriptive and explanatory type where a geotechnical solution strengthening a batter applying Terramesh system, for which stability calculations determining safety factors and failure surfaces of soil applied, proposing to his Once geotechnical parameters are obtained through laboratory testing. A method of stability will apply, which is the input method forces Terramesh resistant type. 2000 MacStars also use software as a tool for sizing and design of reinforced soil wall Terramesh type to be applied on the slope of the road, which will have a minimal environmental impact, restoring communication and helpfulness of the way to the surrounding town. Finally determine the advantages and disadvantages that provides the solution.

Page generated in 0.0481 seconds