• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 6
  • 2
  • 1
  • Tagged with
  • 31
  • 31
  • 18
  • 15
  • 9
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Voltametria adsortiva na determinação de traços e ultra-traços de Zr(IV), V(V),Ti(IV), Mo(VI), Hf(IV), Nb(V) e Ta(V) em águas naturais / Adsorptive voltammetry in the determination of traces and ultra-traces of Zr(IV), V(V), Ti(IV), Mo(VI), Hf(IV), Nb(V) e Ta(V) in natural waters

Schneider, Alexandre Batista 13 March 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Single sensitive sequential AdSV methods were developed and optimized for the determination of trace zirconium, vanadium, titanium and molybdenum in river, estuary and seawater, independent of the salinity and content of organic matter in the sample. The methods are based on the accumulation of Zr(IV)-and V(V)-cupferron-oxalic acid-1,3-diphenylguanidine complexes and the accumulation of Ti(IV)-and Mo(VI)-mandelic acid at the hanging mercury drop electrode (HMDE). Differential pulse, adsorption potential of -0.6, -0.2, -0.1 and -0.1 V (vs. Ag/AgCl), adsorption time of 400, 20, 120 and 1 s and scan rates of 0.01, 0.06, 0.02 and 0.02 V s-1 for Zr(IV), V(V), Ti(IV) and Mo(VI), respectively, were used as instrumental parameters. The reduction peak for the complexes of Zr(IV), V(V), Ti(IV) and Mo(VI) appeared nearly -0.95, -0.65, -0.85 and -0.4 V, respectively. The variations of the peak current as well as the peak potential of each metal complexes were plotted against the apparent ionic strengths. The proposed voltammetric methods were applied in German and Brazilian rivers and estuaries as well as in seawater from the North Sea collected at the north of Germany and the Atlantic Ocean, collected during scientific cruise between Chile and Germany, as interesting and very simple alternatives to very laborious and time-consuming pre-existent methods, based on outline pre-concentration and separation from the matrix and subject to external contamination. The limits of detection and determination were in the range of ppt-levels and the methods accuracy were evaluated by recoveries tests and by measuring V(V) and Mo(VI) in two NRCC reference materials. Estuarine mixtures experiments were also carried out with the aim to get more insight on the distribution of Ti(IV), Zr(IV), Mo(VI) and V(V) along the estuaries of the rivers Rhine, Weser and Elbe with the North Sea. In this context, natural fresh waters were mixed with seawater at different ratios. / Métodos sensíveis e sequenciais de voltametria adsortiva de redissolução foram desenvolvidos e otimizados para a determinação de traços e ultra-traços de zircônio, vanádio, titânio e molibdênio em águas de rio, estuário e mar, independentemente da salinidade e conteúdo de matéria orgânica na amostra. Os métodos são baseados na acumulação de complexos de Zr(IV) e V(V) com cupferron-ácido oxálico-1,3-difenilguanidina e de complexos de Ti(IV) e Mo(VI) com ácido mandélico no eletrodo de mercúrio de gota pendente (HMDE). Pulso diferencial, potenciais de adsorção de -0,6; -0,2; -0,1 e -0,1 V (vs Ag/AgCl), tempos de adsorção de 400, 20, 120 e 1 s e velocidades de varredura de 0,01; 0,06; 0,02 e 0,02 V s-1, para Zr(IV), V(V), Ti(IV) e Mo(VI), respectivamente, foram usados como parâmetros instrumentais. Os picos de redução para os complexos de Zr(IV), V(V), Ti(IV) e Mo(VI) surgiram próximos de -0,95; -0,65; -0,85 e -0,4 V, respectivamente. As variações de corrente de pico assim como de potencial de pico de cada complexo dos metais foram plotados contra as forças-iônicas aparentes das amostras. Os métodos voltamétricos propostos foram aplicados em águas de rio e estuário coletadas na Alemanha e no Brasil e em amostras de água do mar do Mar do Norte coletadas no norte da Alemanha e Oceano Atlântico, coletadas durante expedição científica entre o Chile e Alemanha. Estes métodos se mostraram ser alternativas simples a métodos bastante complexos e demorados, baseados em pré-concentração outline e separação da matriz, sujeitos a contaminação externa. Os limites de detecção e quantificação estavam na ordem de partes por trilhão e a exatidão dos métodos foi avaliada através de teste de recuperação de amostras adicionadas com os analitos em estudo e em 2 materiais de referência certificados. Também foram realizados experimentos de mistura estuarina com o objetivo de obter informações da distribuição de Ti(IV), Zr(IV), Mo(VI) e V(V) ao longo de estuários dos rios Reno, Weser e Elba com o Mar do Norte. Neste intuito, as águas dos rios e do mar foram misturadas em diferentes razões.
22

Desenvolvimento de procedimentos analíticos explorando microextração líquido-líquido em fluxo para a determinação de espécies de interesse em águas e leite / Development of analytical procedures exploiting flow-based liquid-liquid microextraction for the determination of species of interest in waters and milk

Carina de Fátima Nascimento 26 February 2018 (has links)
Três procedimentos analíticos envolvendo microextração líquido-líquido (MELL) em fluxo foram desenvolvidos para as determinações de formaldeído em leite, detergentes aniônicos em águas de rios e bisfenol A (BPA) em águas de torneira. Microextração líquido-líquido dispersiva (MELLD) foi empregada no primeiro e no segundo procedimentos. O primeiro procedimento foi conduzido em um sistema fluxo-batelada no qual a quantificação espectrofotométrica era realizada diretamente na câmara de mistura/reação, através do acoplamento de fibras ópticas. No segundo, foi explorada a estratégia lab-in-syringe, em que a formação do par iônico entre os detergentes aniônicos e corante catiônico azul de metileno, bem como MELLD ocorriam no interior da seringa, sendo os analitos quantificados na fase orgânica por espectrofotometria. O terceiro procedimento envolveu MELL em sistema de análises por injeção sequencial (SIA), baseada na formação de um filme de 1-octanol na parede da bobina de extração. O extrato foi eluído com etanol e a quantificação de BPA foi realizada por espectrofluorimetria. As linearidades das curvas analíticas, os limites de detecção e os limites de quantificação ao nível de 95% de confiança foram: 0,5-5,0 mg L-1, 100 e 300 ?g L-1 para formaldeído, 0,03-0,5 mg L-1, 9,0 e 29,0 ?g L-1 para detergentes, e 5,0 - 100 ?g L-1, 1,8 ?g L-1 e 5,4 ?g L-1 para BPA. Os procedimentos desenvolvidos não apresentaram efeitos de matriz, e as recuperações se situaram entre 91 e 112%. A precisão e exatidão do procedimento foram concordantes com os procedimentos de referência, ao nível de 95% de confiança. Todos os procedimentos apresentaram coeficientes de variação menores do que 3,5% (n=10), frequência de amostragem de 10-17 h-1, consumiram apenas 30-40 µL de solventes orgânicos e geraram 2,7-6,7 mL de resíduos por determinação / Three analytical procedures involving flow-based liquid-liquid microextraction (LLME) were developed for the determinations of formaldehyde in milk, anionic detergents in river waters, and bisphenol A (BPA) in tap waters. The first and second procedures involved dispersive liquid-liquid microextraction (DLLME) and spectrophotometric detection. The first one was carried out in a flow-batch system, in which the spectrophotometric quantification was performed directly in the mixing/reaction chamber by coupling optical fibers. The second one exploited the lab-in-syringe strategy, in which the ion-pair formation between the anionic detergents and the methylene blue cationic dye, as well as DLLME, were carried out inside the syringe. The third procedure involved LLME in a sequential injection system based on the formation of a 1-octanol film on the inner wall of the extraction coil. The extract was eluted with ethanol and BPA was quantified by spectrofluorimetry. Linear response ranges, detection and quantification limits estimated at the 95% confidence level were: 0.5-5.0 mg L-1, 100 and 300 ?g L-1 for formaldehyde; 0.03-0.5 mg L-1, 9.0 and 29.0 ?g L-1 for detergents, and 5.0-100 ?g L-1, 1.8 and 5.4 ?g L-1 for BPA. Matrix effects were not observed for the assayed samples and recoveries ranged from 91 to 112%. Accuracy and precision of the results agreed with those attained by reference procedures at the 95% confidence level. All procedures yielded coefficients of variation lower than 3.5% (n = 10), sampling rates within 10 and 17 h-1, consumed only 30-40 ?L of organic solvents, and generated 2.7-6.7 mL of waste by determination
23

Desenvolvimento de um equipamento portátil e de sistema de análises em fluxo empregando multicomutação. Determinação fotométrica de ferro em águas de rios / Development of a portable equipment and a flow analysis system employing multicommutation. Photometric determination of iron in river waters

Jeová Correia Miranda 20 July 2011 (has links)
O ferro é o elemento mais abundante na Terra e tem importante papel em ciclos biogeoquímicos Neste trabalho foi desenvolvido um procedimento analítico automático para a determinação fotométrica de ferro em águas de rios, empregando um fotômetro baseado em LED e mini-bombas solenoide para o gerenciamento de soluções. O procedimento proposto foi baseado na reação do ferro (III) com o tiocianato de potássio formando um complexo avermelhado com máximo de absorção em 470 nm. Para a determinação de ferro total foi incluída uma etapa de oxidação em linha, usando uma solução de persulfato (S2O82-) como oxidante. O módulo de análises foi constituído por quatro mini-bombas solenoide e uma válvula solenoide de três vias. Para a obtenção de sinais foi construído um fotômetro composto por uma cela de fluxo com caminho óptico de 50 mm, um LED azul (\'lâmbda\'=470 nm) e um fotodetector. Visando utilizar este equipamento portátil para medidas em campo, foram empregadas duas baterias de 6 V para alimentar os dispositivos ativos. Os ensaios em laboratório mostraram que as baterias permitem uma autonomia de mais de 50 horas de trabalho sem recarregá-las. O procedimento desenvolvido apresentou as seguintes características analíticas: resposta linear entre as concentrações de 0,25 e 4,0 mg L-1, segundo a equação Y = (0,0183 ± 0,003) + (0,15326 ± 0,002)X (r=0,9997); limite de detecção 0,013 mg L-1 Fe (III) estimado com 99,7 % de confiança; desvio padrão relativo estimado em 0,95 % (n=15) obtido com uma solução de concentração de 1,5 mg L-1 Fe (III); frequência de amostragem de 50 determinações por hora. Os resultados obtidos pelo procedimento proposto e pelo de referência não apresentaram diferenças significativas com nível de confiança de 95 % / Iron is the most abundant element on Earth and plays an important role in biogeochemical cycles. In this work, an automatic analytical procedure was developed for the photometric determination of iron in river waters, employing a LED-based photometer and solenoid mini-pumps for solution handling. The proposed procedure was based on the reaction between iron (III) and potassium thiocyanate, yielding a red complex with maximum absorption at 470 nm. For the determination of total iron, an in line oxidation step was included, employing a persulfate solution (S2O82-) as oxidant. The module was constructed with four solenoid mini-pumps and a three-way solenoid valve. For data acquisition a photometer was constructed with a 50 mm optical path flow cell, a blue LED (\'lâmbda\'= 470 nm) and a photodetector. Envisioning the use of this portable equipment in field, two 6-Volt batteries were employed to supply energy to the active devices. Laboratory tests showed that the batteries provide more than 50 hours of operation without recharging. The proposed procedure showed the following analytical features: linear response between 0.25 and 4.0 mg L-1, according to the equation Y = (0.0183 ± 0.003) + (0.15326 ± 0.002) X (r = 0.9997); detection limit of 0.013 mg L-1 Fe (III), estimated with 99.7 % of confidence; relative standard deviation estimated as 0.95% (n = 15), obtained with a 1.5 mg L-1 Fe (III) solution; sampling rate of 50 determinations per hour.The results obtained with the proposed and reference procedure did not show significative differences at a 95% confidence level
24

Détection et caractérisation de nanoparticules d’oxyde de zinc par spectrométrie de masse à plasma inductif en mode particule unique (single-particle ICPMS)

Fréchette-Viens, Laurie 08 1900 (has links)
No description available.
25

Procedimentos de análise por injeção sequencial para determinação espectrofotométrica de sulfeto em amostras ambientais explorando a formação do azul de metileno / Sequential injection analysis procedure for spectrophotometric determination of sulfide in environmental samples by exploring the formation of methylene blue

Silva, Marcelo Solitrenick Pinto 13 March 2003 (has links)
Esta tese demonstra a aplicação da análise por injeção seqüencial (SIA) para determinação de sulfeto utilizando a química da formação do azul de metileno, a qual se baseia em dois reagentes: solução de cloridrato de dimetil p-fenileno diamina (DMPD) 3,63 mmol L-1 em meio de HCI 1,1 mol L-1 e solução de cloreto de ferro (III) 19 mmol L-1, também em meio de HCI 1, 1 mol L-1. Estas soluções foram aspiradas para dentro de uma bobina coletora do sistema SIA como duas zonas de reagente, entre as quais aspirava-se a solução da amostra. Em condições otimizadas o limite de detecção foi calculado em 40 µg L-1 de S2-, com uma faixa dinâmica de resposta linear entre 0,05 e 2,0 mg L-1 . Esta faixa linear pode ser ampliada até 32 mg L-1 utilizando-se uma etapa de diluição in-line para concentrações maiores do que 2,0 mg L-1 de S2- . As características de robustez do sistema SIA que utiliza uma bomba de pistão, confere alta estabilidade para as curvas analíticas (precisão de 4%), minimizando a trabalhosa preparação de padrões de S2-. O método foi aplicado na determinação de sulfeto volatilizável por ácidos (AVS) em sedimentos coletados em reservatórios da região metropolitana de São Paulo (RMSP) e no reservatório de Barra Bonita no rio Tietê, localizado 270 km a jusante em relação à cidade de São Paulo. As concentrações de AVS foram 9 a 14 mg kg-1 nos sedimentos de Barra Bonita e entre 1,2 e 14 g kg-1 nos sedimentos dos reservatórios Billings, Pirapora e Rasgão. Esta tese também descreve o acoplamento da análise por injeção seqüencial com análise por fluxo monossegmentado (SI-MSFA) para determinação de sulfeto em níveis de concentração típicos de águas residuais. As curvas analíticas foram construídas por diluição in-line de uma única solução padrão. A robustez do método proposto foi verificada construindo-se curvas analíticas em diferentes dias de trabalho e comparando-se os coeficientes angulares, os quais apresentaram um desvio padrão relativo de 5,2% (n=5) para uma faixa de concentração entre 0,17 e 1,0 mg L-1 de S2-. A freqüência de amostragem foi de 38 análises por hora, com um limite de detecção de 40 µg L-1. A adequabilidade do método SI-MSFA para realizar adições de padrão para determinação de S2- também foi descrita. Amostras simuladas foram analisadas pelo método proposto, apresentando taxas de recuperação entre 70 e 115%, demonstrando a adequabilidade do método SI-MSFA para realizar análise in-situ de S2- em estações automáticas de monitoramento. / This thesis demonstrates the application of sequential injection analysis (SIA) to perform sulfide determination using the methylene blue chemistry, based on two reagents: 3.63 mmol L-1 N,N dimethyl-p-phenylene diamine hydrochloride in 1.1 mol L-1 HCI solution and 19 mmol L-1 FeCl3, also in 1.1 mol L-1 HCI. These solutions are aspirated inside the holding coil of the sequential injection system as two reagent zones sandwiching the sample zone. Under optimized conditions, the detection limit was calculated at 40 µg L-1 S2-, with a linear dynamic range from 0.05 to 2 mg L-1 S2-. This linear range can be extended up to 32 mg L-1 using in-line dilution for sulfide concentrations greater than 2 mg L-1. The robust characteristic of the SI system with syringe pump leads to very stable analytical curves (precision of 4%), minimizing the laborious preparation of sulfide standards. The method was applied in the determination of acid volatile sulfide in river sediments collected at the Metropolitan Area of São Paulo (MASP) City and at the Barra Bonita reservoir, located in the Tietê River, 270 km down river from São Paulo City. The concentrations of acid volatile sulfide were 9 to 14 mg kg-1 in the Barra reservoir and between 1.2 and 14 g kg-1 in sediments from Billings, Pirapora and Rasgão reservoirs. This thesis also describes the coupling of Sequential Injection with Monosegmented Flow Analysis (SI-MSFA) for determination of sulfide at typical concentrations in wastewaters. The analytical curves were constructed by in-line dilution of a single stock standard solution. The robustness of the proposed method was checked constructing analytical curves in different working days and comparing the slopes, which had a relative standard deviation of 5.2 % (n = 5) for a concentration window inside the monosegment between 0.17 and 1.0 mg L-1 S2-. The analytical throughput was 38 samples per hour and the limit of detection was 40 µg L-1. The feasibility of the SI-MSFA approach to perform standard additions for S2- determination was also described. Simulated samples analyzed by the proposed method showed recoveries between 70 and 115%, demonstrating the feasibility of the SI-MSFA method to perform in-situ analysis of S2- in automatic monitoring stations.
26

Mercury species transformations in marine and biological systems studied by isotope dilution mass spectrometry and stable isotope tracers

Lambertsson, Lars January 2005 (has links)
This thesis focuses on the implementation of species-specific isotope dilution (SSID) methodology and stable isotope tracers to determine mercury species occurrence and transformation processes in-situ and during sample treatment. Isotope enriched tracers of methyl-, ethyl- and inorganic mercury were synthesised and applied in different combinations to marine and biological samples. Experimental results were obtained using gas chromatography-inductively coupled plasma-mass spectrometry (GC-ICP-MS). Mercury methylation and methylmercury demethylation processes in surface sediments were studied in the brackish Öre River estuary, Bothnian Bay. Uni- and multivariate data evaluation identified the organic material content and mercury methylation potential in the sediments as important factors controlling incipient methylmercury levels. Mercury species distribution in mice treated with the pharmaceutical preservative Thimerosal (ethylmercurithiosalicylate) was studied. The ethylmercury moiety of Thimerosal was observed to rapidly convert to inorganic mercury in the mice during the treatment period as well as during sample treatment, hence necessitating SSID methodology for accurate ethylmercury determinations in biological samples. To facilitate the introduction of SSID as a routine quantitative method in mercury speciation, a methylmercury isotopic certified reference material (ICRM) was produced. Prior to certification, the stability of the material was examined in conventional and isochronous stability studies spanning 12 months, which permitted uncertainty estimation of the methylmercury amount content for two years of shelf-life. Finally, a field-adapted SSID method for methylmercury determinations in natural water samples was developed. The proposed analytical protocol significantly simplified sample storage- and treatment procedures without sacrifices in analytical accuracy.
27

Origem da acidez da nascente do rio Campo Belo, maciço do Itatiaia - R.J

D’Oliveira, Elisabete Castro 18 December 2017 (has links)
Submitted by Biblioteca de Pós-Graduação em Geoquímica BGQ (bgq@ndc.uff.br) on 2017-12-18T14:58:25Z No. of bitstreams: 1 Dissertação realmente corrigida.pdf: 2600370 bytes, checksum: f6dfd5312d899b3cc7513282683ff5be (MD5) / Made available in DSpace on 2017-12-18T14:58:25Z (GMT). No. of bitstreams: 1 Dissertação realmente corrigida.pdf: 2600370 bytes, checksum: f6dfd5312d899b3cc7513282683ff5be (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Universidade Federal Fluminense. Instituto de Química. Programa de Pós-Graduação em Geoquímica, Niterói, RJ / Pode-se considerar a química das águas naturais dividida em duas categorias de reações mais comuns: as reações ácido-base e as de oxidação-redução. Os fenômenos ácidobase e de solubilidade controlam o pH e as concentrações de íons inorgânicos, resultando em composição química variada de acordo com as condições bioclimáticas. A origem da acidez de uma água natural pode estar relacionada à geoquímica e ao aporte de matéria orgânica e nutrientes, fenômeno frequente em ambientes que apresentam drenagem sob turfeira. As turfeiras são ambientes especiais para estudos relacionados com a dinâmica da matéria orgânica, elas contribuem para o sequestro global de carbono, além de funcionarem como reservatórios de água. Nesse contexto, o objetivo desse trabalho foi analisar a correlação da matéria orgânica e da interação água-rocha com a acidez observada na nascente do rio Campo Belo, situada à 2419 m de altitude, no Maciço do Itatiaia. Para isso, foram coletadas amostras de água e solo, submetidas à analise dos parâmetros físico-químicos in situ e análise dos íons maiores e elementos traço em laboratório. Os resultados encontrados foram utilizados para a realização da modelagem para especiação de íons em água e tratamento estatístico multivariado, que mostraram que a disponibilidade do alumínio no solo está correlacionada com as variações do pH ao longo do perfil. A liberação do alumínio aumenta a acidez do sistema através da hidrólise ácida da água, o que por sua vez, favorece o aumento da desmineralização e lixiviação de bases, favorecendo a concentração e retenção do alumínio no solo. Embora a matéria orgânica não seja responsável pela acidez, a presença da turfa é fator imprescindível para a manutenção da acidez, pois atua como sequestrador de bases ao formar complexos com as substâncias húmicas, além de exercer papel tamponante no sistema. / The chemistry of natural waters can be divided in two more common reaction categories: acid-base reactions, and oxidation-reduction reactions. Acid-base and solubility phenomena control the pH and the inorganic ions concentrations, which result in diverse chemical composition, according to bioclimatic conditions. Acidity origin of natural waters can be related to its geochemistry and to organic matter and nutrient supplies, which are frequent phenomena in environments that present drainage underneath turf. Turfs are special environments for studies related to organic matter dynamic, they contribute to carbon global sequestration, besides functioning as water reservoirs. In that context, the aim of this work was to analyse the correlation between organic matter and water-rock interaction with the acidity observed at the Campo Belo river spring, located at 2419 m of altitude, at the Itatiaia massif. For that, water and soil samples were collected, and analised in terms of their physical-chemical parameters, in situ, and also analysis of the major ions and trace elements in laboratory. The observed results were used in an ion speciation modeling in water, and multivariate statistical analysis, that showed that the availability of aluminum in the soil is correlated to the pH variations along the soil profile. The liberation of aluminum increases the system acidity through acidic hydrolysis of water, which, in turn, promotes the increase of the demineralization and leaching of basis, favoring the concentration and retention of the aluminum of the soil. Despite the organic matter is not responsible for the acidity, the presence of turf is an indispensable factor for the maintenance of the acidity, since it acts as basis sequestrant as it forms complexes with humic substances, besides playing a role in buffering the system.
28

Procedimentos de análise por injeção sequencial para determinação espectrofotométrica de sulfeto em amostras ambientais explorando a formação do azul de metileno / Sequential injection analysis procedure for spectrophotometric determination of sulfide in environmental samples by exploring the formation of methylene blue

Marcelo Solitrenick Pinto Silva 13 March 2003 (has links)
Esta tese demonstra a aplicação da análise por injeção seqüencial (SIA) para determinação de sulfeto utilizando a química da formação do azul de metileno, a qual se baseia em dois reagentes: solução de cloridrato de dimetil p-fenileno diamina (DMPD) 3,63 mmol L-1 em meio de HCI 1,1 mol L-1 e solução de cloreto de ferro (III) 19 mmol L-1, também em meio de HCI 1, 1 mol L-1. Estas soluções foram aspiradas para dentro de uma bobina coletora do sistema SIA como duas zonas de reagente, entre as quais aspirava-se a solução da amostra. Em condições otimizadas o limite de detecção foi calculado em 40 µg L-1 de S2-, com uma faixa dinâmica de resposta linear entre 0,05 e 2,0 mg L-1 . Esta faixa linear pode ser ampliada até 32 mg L-1 utilizando-se uma etapa de diluição in-line para concentrações maiores do que 2,0 mg L-1 de S2- . As características de robustez do sistema SIA que utiliza uma bomba de pistão, confere alta estabilidade para as curvas analíticas (precisão de 4%), minimizando a trabalhosa preparação de padrões de S2-. O método foi aplicado na determinação de sulfeto volatilizável por ácidos (AVS) em sedimentos coletados em reservatórios da região metropolitana de São Paulo (RMSP) e no reservatório de Barra Bonita no rio Tietê, localizado 270 km a jusante em relação à cidade de São Paulo. As concentrações de AVS foram 9 a 14 mg kg-1 nos sedimentos de Barra Bonita e entre 1,2 e 14 g kg-1 nos sedimentos dos reservatórios Billings, Pirapora e Rasgão. Esta tese também descreve o acoplamento da análise por injeção seqüencial com análise por fluxo monossegmentado (SI-MSFA) para determinação de sulfeto em níveis de concentração típicos de águas residuais. As curvas analíticas foram construídas por diluição in-line de uma única solução padrão. A robustez do método proposto foi verificada construindo-se curvas analíticas em diferentes dias de trabalho e comparando-se os coeficientes angulares, os quais apresentaram um desvio padrão relativo de 5,2% (n=5) para uma faixa de concentração entre 0,17 e 1,0 mg L-1 de S2-. A freqüência de amostragem foi de 38 análises por hora, com um limite de detecção de 40 µg L-1. A adequabilidade do método SI-MSFA para realizar adições de padrão para determinação de S2- também foi descrita. Amostras simuladas foram analisadas pelo método proposto, apresentando taxas de recuperação entre 70 e 115%, demonstrando a adequabilidade do método SI-MSFA para realizar análise in-situ de S2- em estações automáticas de monitoramento. / This thesis demonstrates the application of sequential injection analysis (SIA) to perform sulfide determination using the methylene blue chemistry, based on two reagents: 3.63 mmol L-1 N,N dimethyl-p-phenylene diamine hydrochloride in 1.1 mol L-1 HCI solution and 19 mmol L-1 FeCl3, also in 1.1 mol L-1 HCI. These solutions are aspirated inside the holding coil of the sequential injection system as two reagent zones sandwiching the sample zone. Under optimized conditions, the detection limit was calculated at 40 µg L-1 S2-, with a linear dynamic range from 0.05 to 2 mg L-1 S2-. This linear range can be extended up to 32 mg L-1 using in-line dilution for sulfide concentrations greater than 2 mg L-1. The robust characteristic of the SI system with syringe pump leads to very stable analytical curves (precision of 4%), minimizing the laborious preparation of sulfide standards. The method was applied in the determination of acid volatile sulfide in river sediments collected at the Metropolitan Area of São Paulo (MASP) City and at the Barra Bonita reservoir, located in the Tietê River, 270 km down river from São Paulo City. The concentrations of acid volatile sulfide were 9 to 14 mg kg-1 in the Barra reservoir and between 1.2 and 14 g kg-1 in sediments from Billings, Pirapora and Rasgão reservoirs. This thesis also describes the coupling of Sequential Injection with Monosegmented Flow Analysis (SI-MSFA) for determination of sulfide at typical concentrations in wastewaters. The analytical curves were constructed by in-line dilution of a single stock standard solution. The robustness of the proposed method was checked constructing analytical curves in different working days and comparing the slopes, which had a relative standard deviation of 5.2 % (n = 5) for a concentration window inside the monosegment between 0.17 and 1.0 mg L-1 S2-. The analytical throughput was 38 samples per hour and the limit of detection was 40 µg L-1. The feasibility of the SI-MSFA approach to perform standard additions for S2- determination was also described. Simulated samples analyzed by the proposed method showed recoveries between 70 and 115%, demonstrating the feasibility of the SI-MSFA method to perform in-situ analysis of S2- in automatic monitoring stations.
29

Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and waste

Galhardo, Cristiane Xavier 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.
30

Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and waste

Cristiane Xavier Galhardo 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.

Page generated in 0.2163 seconds