• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 157
  • 2
  • Tagged with
  • 162
  • 107
  • 41
  • 41
  • 37
  • 34
  • 19
  • 17
  • 15
  • 15
  • 14
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Modelagem matemática da perda de carga em emissores integrados a tubulação de irrigação localizada / Mathematical modeling of the head loss in integrated emitters pipe localized irrigation

Flores, José Henrique Nunes, Flores, José Henrique Nunes 20 February 2017 (has links)
Submitted by Aline Batista (alinehb.ufpel@gmail.com) on 2017-08-16T14:21:20Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) José_Henrique_Nunes_Flores_Modelagem_matemática_da_perda_de_carga_em_emissores_integrados_a_tubulação_de_irrigação_localizada.pdf: 4719317 bytes, checksum: b86c8f8b440b56d663a03abb04efaf4f (MD5) / Made available in DSpace on 2017-08-16T14:21:20Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) José_Henrique_Nunes_Flores_Modelagem_matemática_da_perda_de_carga_em_emissores_integrados_a_tubulação_de_irrigação_localizada.pdf: 4719317 bytes, checksum: b86c8f8b440b56d663a03abb04efaf4f (MD5) Previous issue date: 2017-02-20 / Sem bolsa / Os objetivos deste trabalho foram: (i) Determinar a perda de carga em função da geometria dos emissores, bem como desenvolver uma relação entre a perda de carga localizada, causada pela inserção do emissor, e as características geométricas da tubulação, mediante a utilização do índice de obstrução, para tubogotejadores com emissores integrados do tipo pastilha; e (ii) Gerar um modelo semiteórico, para estimativa da perda de carga localizada no emissor, causada por sua inserção dentro da tubulação, para tubos emissores integrados do tipo pastilha. Para isso, utilizou-se uma bancada experimental desenvolvida para controle do sistema, e obtenção das variáveis pertinentes ao estudo (vazão, temperatura e perda de carga total no tubo emissor). Obteve-se então, através da utilização da equação da continuidade, a velocidade de escoamento. A partir da diferença da perda de carga total no tubo emissor do valor obtido com o cálculo da perda de carga continua na tubulação, obteve-se a perda de carga localizada causada pela inserção do emissor. Através de um projetor ótico de perfil, foram determinadas as características geométricas dos tubos emissores (áreas de seção transversal e perímetros molhados). Obteve-se, a partir da perda de carga localizada no emissor e da carga cinética, o coeficiente k, e gerou-se um modelo para sua estimativa baseado no índice de obstrução. Desenvolveu-se um modelo semiteórico para estimativa da perda de carga no emissor, a partir do Teorema de Bélanger, levando em consideração as características geométricas da tubulação. Os emissores escolhidos para este estudo são: (a) AZUD Premier Line PC; (b) Naan Dan Jain Amnon Drip AC; e (c) Rain Bird XF-SDI. Os resultados permitiram inferir que a perda de carga total no tubo emissor e a perda de carga localizada no emissor apresentaram relação potencial com a vazão. As razões de obstrução dos emissores foram 0,62, 0,68, e 0,65, e os índices de obstrução 0,37, 0,22, e 0,28, para os emissores AZUD Premier Line PC, Naan Dan Jain Amnon Drip AC, e Rain Bird XF-SDI, respectivamente. Já os coeficientes k foram, respectivamente, 1,03, 1,07, e 0,86, para os emissores AZUD Premier Line PC, Naan Dan Jain Amnon Drip AC e Rain Bird XF-SDI. O modelo potencial correlacionando o coeficiente k com o índice de obstrução, foi k=1,66 IO0,413. Em relação ao modelo semiteórico proposto, houve superestimava em 9% e 2%, para os emissores AZUD Premier Line PC e Rain Bird XF-SDI, respectivamente, e subestimativa em 34% para o emissor Naan Dan Jain Amnon Drip AC, apresentando ajuste considerado muito bom, através do índice c, para os três emissores estudados. Conclui-se que cada emissor apresentou um valor para o coeficiente k, existindo correlação com a geometria do tubo emissor, e que o modelo semiteórico proposto, pode ser utilizado para emissores de geometria semelhantes ao AZUD Premier Line PC e Rain Bird XFSDI. / The objectives of this work was: (i) To determine the variability of the head loss as a function of the geometry of the emitters, as well as to develop a relation between the local head loss caused by the emitter insertion and the geometric characteristics of the emitting pipe, using the obstruction index, for emitting pipes with non-coaxial emitters; and (ii) Generate a semi-analytical model to estimate the local head loos in the emitter, caused by its insertion into the pipeline, for emitting pipes with non-coaxial emitters. For this, an experimental bench was developed to control the system and obtain the variables pertinent to the study (flow, temperature and total head loss in the emitter pipe). Then, through the use of the continuity equation, the flow velocity was obtained. From the difference of the total head loss in the emitter pipe and the value obtained with the calculation of the continuous head loss in the pipeline, the local head loss caused by the insertion of the emitter was obtained. The geometric characteristics of the emitting tubes (cross-sectional areas and wetted perimeters) were determined through an optical profile projector. The k coefficient was obtained from the local head loss in the emitter and kinetic energy, and a model was generated for its estimation based on the obstruction index. A semi-analytical model was developed to estimate the head loss in the emitter from the Bélanger Theorem, taking into account the geometric characteristics of the pipe. The emitters chosen for this study are: (a) AZUD Premier Line PC; (b) Naan Dan Jain Amnon Drip AC; And (c) Rain Bird XF-SDI. The results allowed to infer that the total head loss in the emitter pipe and the local head loss in the emitter presented a potential relation with the flow rate. Emitter obstruction ratio were 0.62, 0.68, and 0.65, and obstruction index was 0.37, 0.22, and 0.28 for the emitters AZUD Premier Line PC, Naan Dan Jain Amnon Drip AC, and Rain Bird XFSDI, respectively. The k coefficients were 1.03, 1.07 and 0.86, respectively, for the AZUD Premier Line PC, Naan Dan Jain Amnon Drip AC and Rain Bird XF-SDI emitters respectively. The potential model correlating the k coefficient with the obstruction index was k=1,66 OI0,413. In relation to the proposed semi-analytical model, there was a 9% and 2% overestimation of the AZUD Premier Line PC and Rain Bird XF-SDI emitters, respectively, and a 34% underestimation by Naan Dan Jain Amnon Drip AC, but presenting an adjustment considered very good, through the index c, for the three emitters studied. It is concluded that each emitter presented a value for the k coefficient, there being a correlation with the geometry of the emitter tube, and that the proposed semi-analytical model can be used for geometric emitters similar to AZUD Premier Line PC and Rain Bird XF-SDI.
32

A obstrução de Euler de uma função / The Euler obstruction of a function

Daiane Alice Henrique 25 January 2013 (has links)
Nosso objetivo neste trabalho é estudar a obstrução de Euler de uma função, este conceito foi definido por J.-P. Brasselet, D. Massey, A. J. Parameswaran e J. Seade, e generaliza dois conceitos importantes, a obstrução de Euler definida por R. D. MacPherson assim como o número de Milnor de uma função. O resultado principal deste trabalho mostra a relação existente entre a obstrução de Euler e a obstrução de Euler de uma função / Our goal in this work is to study the Euler obstruction of a function, this concept was defined by J.-P. Brasselet, D. Massey, A. J. Parameswaran and J. Seade, and it generalizes two important concepts, the Euler obstruction defined by R. D. MacPherson and the Milnor number of a function. The main result of this study shows the relation between the Euler obstruction and the Euler obstruction of a function
33

Obstrução de Euler de aplicações analíticas / Euler obstruction of analytic maps

Grulha Júnior, Nivaldo de Góes 28 November 2007 (has links)
Neste trabalho determinamos relações entre a obstrução de Euler de uma função analítica com singularidade isolada f e o número de Milnor de f definido por Bruce e Roberts para funções definidas em espaços singulares. Apresentamos também uma generalização da obstrução de Euler de uma função analítica com singularidade isolada para o caso de uma aplicação \'f : (V, 0) seta (\'C POT. k\', 0) onde (V, 0) é o germe de uma variedade analítica complexa, equidimensional de dimensão \' n > OU = k\' , e uma fórmula para calcular a obstrução de Euler de k-referenciais, em termos da obstrução de Euler de f / In this work we determine relations between the local Euler obstruction of an analytic function singular at the origin to the case of a analytic map \'f : (V, 0) seta (\'C POT. k, 0\'), where (V, 0) is the germ of a complex analytic variety, equidimensional of dimension \' n > OU = k\', and a formula which computes the local Euler obstruction, defined for k-frames, in the local Euler obstruction of f
34

Concentração e granulometria de partículas de areia na obstrução de gotejadores / Sand particles concentration and size in the clogging of drip emmiters

Talamini Junior, Marcus Vinicius 29 June 2018 (has links)
O principal problema da irrigação por gotejamento é a obstrução dos emissores. Dentre os diversos agentes causadores da obstrução, os de natureza física se mostram, de acordo com estudos feitos até o momento, os de maior importância e ocorrência. Esse problema acarreta graves consequências para o sistema de irrigação, seja por efeito na uniformidade de aplicação de água, ou por redução da vida útil do sistema. Até o momento não existe uma norma técnica que especifica a metodologia a ser utilizada para se testar a sensibilidade de gotejadores à obstrução, todavia, o Plateforme de Recherche et d\'expérimentation en Sciences et Technologies d\'Irrigation de l´Institut National de Recherche en Sciences et Technologies de l´Environnement et l\'Agriculture (PReSTI/IRSTEA) propôs um procedimento para avaliar materiais comerciais de irrigação que vem sendo utilizado há 40 anos. Tomando-se em conta esse método e pesquisas realizadas anteriormente pelo Laboratório de Ensaios de Materiais de Irrigação (LEMI/ESALQ), foi feito um estudo para avaliar a influência da granulometria e da concentração de partículas de areia no processo de obstrução de gotejadores, eliminando-se outros agentes de obstrução, de origem física, química ou biológica. Para tal finalidade, foram escolhidos quatro modelos de gotejadores previamente testados no LEMI (Drip-Tech 1,2 e 1,6 L h-1 e Taldrip 0,6 e 1,7 L h-1). Um solo natural foi utilizado para a obtenção de partículas de areia, o qual passou por um processo de preparação através da destruição de matéria orgânica, dispersão das partículas presentes e peneiramento de partículas para separação de acordo com suas dimensões. A areia foi separada em 3 faixas granulométricas: de 63 a 125 μm, de 125 a 212 μm e de 212 a 500 μm. Cada faixa granulométrica foi testada com quatro concentrações: 125 mg L-1, 250 mg L-1, 375 mg L-1 e 500 mg L-1 . O composto de partículas sólidas correspondente a cada condição de ensaio foi misturado em água deionizada, num reservatório de 200 L. Cada combinação de granulometria e concentração era testada por 40 h, sendo 8 h por dia, totalizando 5 dias úteis. Para evitar crescimento microbiano, cloro era adicionado diariamente. Observou-se que os 3 modelos de gotejador de maior vazão não se mostraram susceptíveis à obstrução por partículas de areia, enquanto o modelo de vazão 0,6 L h-1 apresentou obstrução severa em todos os casos, asim como um comportamento anômalo na concentração de 125 mg L-1 da faixa granulométrica 63 a 125 μm, pois a obstrução aqui se mostrou mais severa do que nos casos de diferentes concentração dessa mesma faixa granulométrica. Independente de qual granulometria ou concentração era utilizada, no modelo de vazão 0,6 L h-1, não foi possível diferenciar o efeito da granulometria e da concentração nesse processo. / The main problem in drip irrigation is the clogging of emitters. Among the many agents participating in the clogging process, the ones of physical nature, according to studies performed until now, the most important and occurrent ones. This problem has serious consequences for the irrigation system, either by influencing the water application uniformity or reducing the system lifespan. So far, there is no technical standard that specifies the methodology to be used when testing drippers\' sensitivity to clogging, nonetheless, the Plateforme de Recherche et d\'expérimentation en Sciences et Technologies d\'Irrigation de l´Institut National de Recherche en Sciences et Technologies de l´Environnement et l\'Agriculture (PReSTI/IRSTEA) did propose a method to evaluate commercial irrigation material that has been used for 40 years. Considering this method and research previously performed at the Irrigation Material Testing Laboratoy (LEMI/ESALQ), a study was performed trying to identify the influence of sand particles\' size and concentration on the emitter clogging process, controlling clogging agents of other nature, either of physical, chemical or biological nature. To achieve this objective, four emitters models, previously tested at LEMI were selected (Drip 1,2 and 1,6 L h-1 and Taldrip 0,6 and 1,7 L h-1). A natural soil was collected to obtain sand particles, it went under a chemical treatment by having its organic matter removed, solid particles dispersed and subsequently sieved to separe it according to its size. Sand was separed in 3 size ranges (from 63 to 125 μm, from 125 to 212 μm and from 212 to 500 μm). Each size range was tested in four different concentrations (125 mg L-1, 250 mg L-1, 375 mg L-1 and 500 mg L-1). The water used in this experiment was deionized, to avoid the presence of salts and the solution of water and sand was previously prepared, before being used, in a reservoir containing 200 L of capacity. Each combination of particle size and concentration was tested for 40h, or 8h a day, for 5 days. To avoid microbian microorganism growth, clorine was added daily to the water. The 3 emitter models with higher flow rates had no sensitivity to the clogging process under this experiment conditions, nonetheless, the model of flow rate 0,6 L h-1 was severely clogged on all cases, no matter the particle size or concentration and there was an anomalous behavior for the concentration 125 mg L-1 from the 63 to 125 μm size range, for here clogging was much more severe than the other concentrations from the same size range. Independentely from the particle size range and concentration on the test, the effects of each component isolated were not detectable in this process.
35

Fatores prognósticos em pacientes submetidos à desobstrução ureteral secundária a tumores urológicos ou extraurológicos / Prognostic factors in patients submitted a urinary diversion for urologic or nonurologic malignancies

Cordeiro, Mauricio Dener 11 April 2014 (has links)
INTRODUÇÃO E OBJETIVOS: Há controvérsias em relação à indicação e ao momento ideal de realização de derivação urinária em pacientes com obstrução ureteral secundária a neoplasias malignas avançadas. O objetivo do presente estudo foi identificar fatores relacionados ao mau prognóstico de pacientes com nefropatia obstrutiva maligna e criar um modelo de estratificação de risco desses pacientes, a fim de fornecer evidências para uma melhor decisão terapêutica. MÉTODO: Realizou-se estudo prospectivo com pacientes portadores de insuficiência renal obstrutiva por neoplasias pélvicas, acompanhados por um tempo mínimo de seis meses, tratados entre janeiro de 2009 à novembro de 2011. De um total de 340 pacientes submetidos à procedimentos de descompressão ureteral por catéter ureteral (CUR) ou nefrostomia percutânea (NPC), 208 foram incluídos no estudo por serem maiores de 18 anos, apresentarem obstrução ureteral secundária à neoplasias malignas, confirmada por tomografia computadorizada (TC) ou ultrassom (USG) e por terem realizado derivação urinária por catéter ureteral ou nefrostomia percutânea em nossa Instituição. RESULTADOS: A sobrevida média global foi de 144 dias, com mortalidade ao final do estudo de 164 pacientes (78.8%), sendo 44 (21.2%) durante a internação hospitalar. Não houve diferença significativa na sobrevida global entre os dois tipos de derivação urinária realizada (p = 0.216). Após análise univariada, a presença de qualquer sintoma (p = 0.014), derrame pleural (p = 0.015), grau de hidronefrose 1 e 2 (p = 0.001), Índice de Charlson >= 6 (p = 0.003), linfonodos retroperitoneais metastáticos (p = 0.002), linfonodos pélvicos metastáticos (p = 0.024), número de sítios relacionados à disseminação da doença >= 4 (p < 0.001), niveis séricos iniciais de uréia >= 80mg/dl (p = 0.01), sódio <= 138 mEq/L (p = 0.018) e albumina < 3.0 mg/dl (p = 0.035), diálise peri-operatória (p = 0.05) e índice de ECOG PS (Eastern Cooperative Oncology Group Performance Status) >= 2 (p < 0.001), foram associados a menor sobrevida média. A análise multivariada de Cox revelou que apenas o número de sítios relacionados à disseminação maligna (quatro ou mais) e o índice de ECOG PS >= 2 foram significativamente associados à menor sobrevida. A fim de criar um modelo de estratificação de risco, os pacientes foram, posteriormente, divididos em três grupos: nenhum fator de risco - grupo I, um fator de risco - II e dois fatores de risco - III. As taxas de sobrevida mediana de 1,6 e 12 meses nesses grupos foram, respectivamente de 94.4%, 57.3% e 44.9% no grupo I, de 78.0%, 36.3% e 15.5% no grupo II e de 46.4%, 14.3% e 7.1% no grupo III, com diferenças significativas nos perfis de sobrevivência dos três grupos de risco (p < 0.001). CONCLUSÕES: Nosso modelo de estratificação de risco poderá representar uma ferramenta útil na decisão de se instituir procedimentos de desobstrução ureteral em pacientes com neoplasias abdominopélvicas malignas avançadas. Pacientes com mais de quatro sítios de metástases e com índice de performance (ECOG) igual ou superior a 2 apresentam pobre evolução após derivações urinárias realizadas para tratar nefropatia obstrutiva maligna. De acordo com o método de estratificação de risco de óbito por nós descrito, pacientes com um ou mais fatores de risco evoluem com sobrevida mais precária que os casos sem fatores de risco presentes / INTRODUCTION AND OBJECTIVES: There is a controversy regarding the decision to perform diversion procedures in patients with ureteral obstruction secondary to advanced malignancies. The goal of this study was to identify poor prognosis factors and to create a model to stratify patients with malignant obstructive nephropathy in order to provide evidence-based information for better treatment decisions. METHODS: A prospective study was performed from January 2009 to November 2011, with patients followed at least for 6 months. From 340 patients initially submitted to ureteral decompression procedures by ureteral stents or percutaneous nephrostomy, 208 were elected for the study because they were 18 years old or more and presented ureteric obstruction secondary to any type of malignancy, confirmed by computadorized tomography (CT) or ultrasound (US) and were submitted to urinary diversion by ureteral stents or percutaneous nephrostomy at our institution.RESULTS: The median survival for all patients was 144 days, with mortality at the end of study seen in 164 patients (78.8%) including 44 (21.2%) during hospitalization. There was no significant difference in overall survival between the two types of urinary diversion (p = 0.216). After univariated analysis the presence of any symptoms (p = 0.014), pleural effusion (p = 0.015), degree of hydronephrosis 1 and 2 (p = 0.001), Charlson Index >= 6 (p = 0.003), metastatic retroperitoneal lymph nodes (p = 0.002), metastatic pelvic lymph nodes (p = 0.024), number of sites related to dissemination >= 4 (p < 0.001), preoperative serum level urea >= 80mg/dl (p = 0.01), sodium <= 138mEq/L (p = 0.018), albumin < 3.0 mg/dl (p = 0.035), perioperative dyalisis (p = 0.05) and ECOG PS index >= 2 (p < 0.001) were associated to shorter mean survival. The multivariate Cox proportional hazards regression model revelead that only the number of sites related to malignant dissemination (4 or more) and the index of performance status of Eastern Cooperative Oncology Group (ECOG PS >= 2) were significantly associated with short survival. To creat a risk stratification model, the patients were further divided into three risk groups: no risk factor - favorable group, one risk factor - intermediate and two risk factors - unfavorable, to creat a risk stratification model. The median survival rates at 1,6 and 12 months were respectively, 94.4%, 57.3% and 44.9% in the favorable group; 78.0%, 36.3% and 15.5% in the intermediate group and 46.4%, 14.3% and 7.1% in the unfavorable group. There were significant differences in the survival profiles of the three risk groups (p < 0.001). CONCLUSION: Our model of stratification may be a useful tool before deciding on ureteral desobstruction procedures in patients with advanced abdominopelvic malignancies. Patients with more than four sites of metastases and performance index (ECOG) equal to or greater than 2 have a poorer outcome after urinary diversion. According to the method of risk stratification for death from we described, patients with one or more risk factors have significant poorer outcome than cases with no risk factors
36

Números de Milnor e obstrução de Euler / Milnor numbers and Euler obstruction

Menegon Neto, Aurelio 27 June 2007 (has links)
Neste trabalho, definimos a obstrução local de Euler de um espaço analítico complexo singular (X, \'x IND.0\'), denotada por Eu(X, \'x IND.0\'), e a obstrução local de Euler de uma função holomorfa f definida neste espaço, com uma singularidade isolada em \'x IND. 0\', denotada por \'Eu IND. f\' (X, \'x IND.0\'); e apresentamos duas fórmulas para seus respectivos cálculos. Em seguida, através de uma abordagem geométrica, determinamos as relações entre \'Eu IND. f\' (X,\'x IND.0\') e algumas generalizações do número de Milnor para funções em espaços singulares / In this work we define the local Euler obstruction of a complex analytic singularity (X, \'x IND.0\'), denoted Eu(X, \'x IND.0\'), and the local Euler obstruction of a holomorphic function f defined on this space, with an isolated singularity at \'x IND. 0\', denoted \'Eu IND. f\' (X, \'x IND.0\'); and we present two formulas for their respective calculations. Next, using a geometric approach, we determine the relations between \'Eu IND.f\' (X, \'x IND.0\') and several generalizations of the Milnor number for functions on singular spaces
37

Efeitos da N-acetilcisteína na resposta inflamatória e na translocação bacteriana em modelo de obstrução e isquemia intestinal em ratos / Evaluate the effect of N-acetylcysteine in the inflammatory response and the translocation in an experimental model of intestinal obstruction and ischemia

Costa, Rafael Izar Domingues da 26 September 2017 (has links)
A obstrução intestinal mecânica representa uma condição de urgência, necessitando diagnóstico precoce e terapêutica adequada, em virtude do seu elevado grau de morbidade e de mortalidade. Desta forma, o objetivo deste estudo foi avaliar o efeito da N-acetilcisteína associada ao Ringer lactato ou à solução salina hipertônica na resposta inflamatória, histologia e translocação bacteriana em modelo experimental de obstrução e isquemia intestinal. Para tanto, Foram constituídos quatro grupos experimentais, com 10 ratos Wistar em cada, além do grupo de referência: OI - Submetidos a obstrução e isquemia intestinal e enterectomia com anastomose intestinal, sem reanimação volêmica; RL - Submetidos a obstrução e isquemia intestinal, reanimação volêmica com Ringer lactato (32ml/kg, i.v., em 10 minutos) e enterectomia com anastomose intestinal; RLNAC - Submetidos a obstrução e isquemia intestinal, reanimação volêmica com Ringer lactato associado a NAC (32ml/kg + 150 mg/kg i.v. em 10 minutos) e enterectomia com anastomose intestinal; SHNAC - Submetidos a obstrução e isquemia intestinal, reanimação volêmica com solução salina hipertônica a 7,5% associado com NAC (4ml/kg + 150 mg/kg i.v., em 10 minutos) e enterectomia com anastomose intestinal. Grupo Referência (n=5): Animais anestesiados, submetidos a coleta de materiais para cultura e histologia e sacrificados por exsanguinação. Os animais receberam uma associação anestésica de cetamina e xilazina intramuscular em membro posterior direito, na dose de 60mg/kg e 10mg/kg, respectivamente. Decorridas 24 h do tratamento, a eutanásia foi realizada por exanguinação, sob anestesia, após a coleta dos tecidos / Mechanical intestinal obstruction represents a condition of urgency, necessary early diagnosis and appropriate therapy, due to their high degree of morbidity and mortality. In this way, the objective of this study was to evaluate the effect of N-acetylcysteine associated with lactated Ringer\'s or hypertonic saline solution in the inflammatory response, histology and translocation in an experimental model of intestinal obstruction and ischemia. For Four experimental groups were constituted with 10 Wistar rats each, in addition to the reference group: OI - submitted to obstruction and ischemia intestinal and enterectomy with intestinal anastomosis, without volume resuscitation; RL - Undergoing intestinal obstruction and ischemia, volume resuscitation with Ringer\'s lactate (32ml / kg, i.v., within 10 minutes) and anastomosis enterectomy intestinal; RLNAC - Undergoing obstruction and intestinal ischemia, resuscitation with lactated Ringer\'s lactating NAC (32 ml / kg + 150 mg / kg i.v. in 10 minutes) and enterectomy with intestinal anastomosis; SHNAC - Submitted to obstruction and intestinal ischemia, volume resuscitation with saline solution hypertension at 7.5% associated with CAP (4 ml / kg + 150 mg / kg i.v., in 10 minutes) and enterectomy with intestinal anastomosis. Reference Group (n = 5): Anesthetized animals, submitted to collection of materials for culture and histology and sacrificed by exsanguination. The animals received a anesthetic association of ketamine and intramuscular xylazine in limb posterior right, at the dose of 60mg / kg and 10mg / kg, respectively. After 24 h of treatment, euthanasia was performed by exsanguination, under anesthesia, after collection of tissues
38

Efeito do pulso de partículas sólidas na obstrução de tubogotejadores / Effect of solid particles pulse on the obstruction of drip line (Irrigation)

Amaral, Marcos Antonio Correa Matos do 27 September 2017 (has links)
Para que o sistema de irrigação localizada opere com uma boa uniformidade de aplicação, é necessário que sejam adotas boas práticas de instalação e manejo, como também, que a fonte de água atenda aos requisitos de qualidade exigida e que o sistema de filtragem contribua para reduzir os riscos de obstrução. Entretanto, há condições em que o risco de obstrução pode ocorrer após o sistema de filtragem. Procedimentos inadequados de montagem e manutenção da linha podem levar a entrada de partículas sólidas que oferecem risco de obstrução. A característica da partícula associada a posição da linha pode favorecer ou reduzir os riscos de obstrução. O trabalho teve como objetivo avaliar o efeito do pulso de partículas em diferentes posições de linha. O experimento foi realizado no Instituto Nacional Ciência e Tecnologia em Engenharia de Irrigação, INCT-EI, vinculado ao Laboratório de Irrigação do Departamento de Engenharia de Biossistemas, da Escola Superior de Agricultura \"Luiz de Queiroz\"- (ESALQ/USP). Foram avaliados dois modelos de tubos gotejadores com emissores convencionais (não compensantes), integrados, de formato plano (tipo pastilha), submetidos a pulso por partículas sólidas combinando três fatores: posição da linha (para cima, para baixo e para o lado), diâmetro da partícula (0,05-0,1mm; 0,1-0,25mm; 0,25-0,5mm), concentração de partículas (5g, 10g e 20g), em sete posições de gotejadores na linha espaçados a cada 0,5 m. Foi utilizado o delineamento de blocos não casualizados, e para a comparação das médias de vazões relativas, foi adotado o teste de Tukey com significância de 5% e 10% na análise de variância. A análise fatorial revelou que o modelo de gotejador 1 apresenta maior susceptibilidade a obstrução nos quatro primeiros gotejadores, com diferença significativa para fatores isolados quanto em interação. O modelo 2 não apresentou diferença estatística para o fator concentração. Para os demais fatores e interações, foi observado que gotejadores mais distantes também podem apresentar redução de vazão quando submetidos ao pulso. Em ambos modelos, observou-se que o diâmetro da partícula é um fator que influencia a obstrução de gotejadores. Os gotejadores iniciais estão mais propensos a obstrução quando submetidos a pulsos de partículas. A posição da linha voltada para o lado contribui para redução dos riscos de obstrução. / For an irrigation system located operate with good uniformity of application, it is necessary to adopt good installation and management practices, as well as the water source meets the required quality requirements and the filtering system contributes to reduction of obstruction\'s risks. However, there are conditions where the risk of obstruction may occur after the filtering system. Inadequate line assembly and maintenance procedures can lead to the entry of solid particles that allow the clogging emitters. The particle characteristic associated with lineage may favor or reduce the risk of obstruction. The objective of this work was to evaluate the effect of the pulse of particles in different positions of the line. The experiment was carried out at the National Institute of Science and Technology in Irrigation Engineering, INCT-EI, linked to the Irrigation Laboratory of the Department of Biosystems Engineering, School of Agriculture \"Luiz de Queiroz\" - (ESALQ / USP). Two tube models of conventional drippers (non-compensating) were submitted to pulses by solid particles combining three factors: line position (up, down and to the side), particle diameter (0.05-0.1 mm, 0.1-0.25mm, 0.25- 0.5mm), particle concentration (5g, 10g and 20g) in seven positions of drippers in the line spaced every 0.5 m. The design of non-randomized blocks was used, and the Tukey test with significance of 5% and 10% as analysis of variance for comparison of means. The factorial analysis revealed that the model drip tube 1 presented greater susceptibility to obstruction in the first four drippers, with a significant difference for factors isolated and in interaction. The model 2 did not present statistical difference for the concentration factor, however, for the other factors and interactions, it was observed that more distant drippers can also present reduction of flow when submitted to the pulse. In both models, it was observed that the particle diameter is a factor that influences the drip obstruction. It has been observed that the diameter of the particle is a factor that influences the obstruction of drippers. The initial drippers are more prone to obstruction when subjected to pulses of particles. The position of the line facing the side of the contributed to reduces the risk of obstruction.
39

Desenvolvimento e avaliação de um sistema de filtragem com reversão de fluxo de alta frequência / Development and assessment of filtration in irrigation system with high frequency reversal flow

Pinto, Marinaldo Ferreira 18 June 2013 (has links)
A obstrução de emissores tem sido um entrave para a microirrigação. Porém, tem-se notado poucos estudos relativos ao desenvolvimento de equipamentos que auxiliam na prevenção da obstrução de emissores nos últimos anos. Os estudos realizados nesta linha estão geralmente ligados à caracterização dos sistemas em uso. O objetivo deste trabalho foi desenvolver um sistema de filtragem com reversão automática de fluxo, de alta frequência. O sistema foi concebido para operar com água de baixa qualidade, com inversão de fluxo e limpezas automáticas e com volume mínimo de água para realização das limpezas. As decisões do controlador do sistema de filtragem têm como base a perda de carga, obtida por meio de transdutores de pressão instalados na entrada e na saída do sistema. O protótipo final é composto, basicamente, por três filtros de tela e onze válvulas solenoides controladas eletronicamente. Determinou-se a curva de perda de carga em função da vazão, a eficiência de retenção e o volume mínimo de água para limpeza dos filtros. A eficiência de retenção de partículas foi determinada em delineamento experimental inteiramente aleatorizado em esquema fatorial, sendo testados três fatores: tempo de reversão (15 e 30 s); incremento da perda de carga (25 e 50%) e concentração de sólidos (500 e 1000 mg L-1). A eficiência de retenção de sólidos totais foi de 71,7 e 78,3% para as concentrações de 500 e 1000 mg L-1, respectivamente, tendo apresentado diferença significativa a 1% de probabilidade. Entretanto, a eficiência retenção de sólidos maiores que 50 ?m (Ed > 50) foi de 98,6 ± 0,7%, não sendo significante para nenhum dos tratamentos ao nível de significância de 1%. O volume médio de água despendido durante as limpezas foi de 5,39 L por limpeza, que representou um volume de água de limpeza por volume de água filtrada de 8,0 e 12,6 L m-3, para as concentrações de 500 e 1000 mg L-1, respectivamente. Os valores de eficiência energética do sistema de filtragem variaram de 80 a 90% para a vazão de 2 m3 h-1 com pressão de entrada entre 15 a 40 mca. As limpezas do sistema de filtragem não foram totalmente eficazes na retomada da perda de carga, com tendência de aumento com o tempo. A inversão de fluxo com frequências de 11,11 e 22,22 mHz influenciou na evolução da perda de carga do sistema de filtragem, tornando-a mais lenta que a evolução para o sistema funcionando sem inversão de fluxo. Considerou-se que o sistema de filtragem desenvolvido apresentou potencial para filtragem da água de irrigação com baixa qualidade, porém necessita de manutenções periódicas para limpeza do elemento filtrante. A perda de carga admissível do sistema de filtragem deve ser o valor mais restritivo entre o critério de desempenho de retenção de partículas e o de variação de vazão do sistema de irrigação. / Emitters clogging have been a barrier to trickle irrigation. Just a few studies have been performed concerning equipments which assist in preventing emitters clogging in recent years, especially regarding to development equipment. Studies carried out on this issue are usually linked to the characterization of systems in use. The aim of this study was to develop a filtering system with automatic flow reversal of high frequency. The system is designed to operate with low quality water, with reverse flow and automatic cleanings and with minimum volume of water to perform the cleaning. Decisions by the controller of the filtration system are based on head loss, obtained by pressure transducers installed at the upstream and downstream of the system. The final prototype consists of three screen filters and eleven electronically controlled solenoid valves. The curve of head loss was determined as a function of water flow, retention efficiency and minimum volume of water required for cleaning the filters. The efficiency in particle retention was determined following a completely randomized experimental design in a factorial scheme in which three factors were tested: reversal time (15 and 30 s) increase in head loss (25 and 50%) and solids concentration (500 and 1000 mg L-1). The total solids retention efficiency was 71.7 and 78.3% for concentrations of 500 and 1000 mg L-1, respectively, presenting a significant difference at 1%. However, when analyzing the retention efficiency of solids larger than 50 ?m (Ed> 50), none of the treatments was significant at 1%, whose efficiency was 98.6 ± 0.7%. The mean volume of water expended during the cleaning was 5.39 L. It represented a volume of water for cleaning per volume of filtered water from 8.0 and 12.6 L m-3, to concentrations of 500 and 1000 mg L-1, respectively. The energy efficiency values of filtering system ranged from 80 to 90% considering flow rate of 2 m3 h-1 and inlet pressure ranging from 15 to 40 mca. The filtering system cleaning was not totally effective in reestablishing the head loss, with an upward trend over time. The reverse flow with frequency of 11.11 and 22.22 mHz influenced the head loss evolution of the filtration system, making it slower than the trend for the system running without flow reversal. The developed filtration system has potential for filtering low quality irrigation water, but it requires periodic maintenance to clean the filter element. The allowable head loss of the filter system should be the most restrictive value between the criterion of particle retention performance and the flow variation of the irrigation system because of the increase in head loss in the filters.
40

Estudos urodinâmicos sobre o uso da manobra de Valsalva na micção nos homens com hérnia inguinal acima de 50 anos

Ting, Hsu Yuan 20 July 2006 (has links)
Made available in DSpace on 2016-03-22T17:27:38Z (GMT). No. of bitstreams: 1 dissert Hsu.pdf: 195088 bytes, checksum: ff892d262a8527b185d450fb567d2b05 (MD5) Previous issue date: 2006-07-20 / Verificar se a presença de manobra de Valsalva durante a micção em pacientes portadores de hérnia inguinal está associada aos achados urodinâmicos específicos. Método: homens portadores de hérnia inguinal, com idade igual ou superior a 50 anos, que compareceram ao ambulatório de cirurgia geral no período de maio de 2003 a novembro de 2005, foram submetidos ao estudo urodinâmico, sendo avaliados principalmente a resistência uretral média (URA), a contratilidade isométrica detrussora (Pw) e o resíduo miccional. Os pacientes foram divididos em um grupo sem uso da manobra de Valsalva durante a micção (grupo I) e outro com presença da manobra (grupo II). Inicialmente, os dados foram expressos através das médias dos parâmetros analisados; após foram dicotomizados conforme os valores de referência; e, para análise estatística, empregou-se o teste do qui quadrado e regressão logística não condicional. Resultado: Participaram 100 pacientes, com média de idade de 64,2 anos (DP de +-9,7 anos). O grupo I foi composto por 52 pacientes e o grupo II, por 48 pacientes. As médias dos parâmetros urodinâmicos foram comparadas entre os dois grupos. Constatou-se que o grupo que realizava manobra de Valsalva 33 durante a micção apresentava uma contratilidade detrussora comprometida (p<0,01) e um resíduo miccional aumentado (p<0,02). Ao utilizar-se a regressão logística para expressar as razões de odds, foi encontrado OR de 2,57 (IC 95%: 1,09-6,06) no grupo de hipocontratilidade detrussora. Conclusão: a manobra de Valsalva durante a micção associa-se com a presença de hipocontratilidade detrussora em portadores de hérnia inguinal

Page generated in 0.0492 seconds