• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 215
  • 15
  • 15
  • 15
  • 15
  • 13
  • 13
  • 10
  • 7
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 219
  • 118
  • 101
  • 93
  • 62
  • 62
  • 58
  • 58
  • 43
  • 37
  • 37
  • 37
  • 31
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Avaliação das forças, momentos e binding, produzidos por deformação de primeira ordem do fio NiTi .014 superelástico, em braquetes autoligáveis passivos estudo in vitro / Evaluation of force, moment and binding produced by first order deformation on a superelastic .014 Niti wire using passive self-ligated brackets in vitro study

Queiroz, Gilberto Vilanova 09 April 2010 (has links)
Os efeitos mecânicos exercidos sobre os dentes pela deformação do fio de níqueltitânio dependem de sua rigidez e das características dos braquetes. Os fatores associados ao braquete são a largura, que influencia o comprimento de fio interbraquetes e o coeficiente de atrito. O objetivo desta pesquisa foi comparar a influência dos braquetes autoligáveis passivos Damon, Easy Clip e Smart Clip, sobre as forças, momentos e binding produzidos pela deformação do fio Contour NiTi .014. Metodologia: um dispositivo de simulação clínica com 3 braquetes .022x.028 de aço, correspondentes ao canino e pré-molares, foi acoplado à maquina de tração universal Instron para registro das forças e ao dinamômetro Lutron para registro dos momentos na unidade de ancoragem. A deformação de primeira ordem do fio superelástico Contour NiTi .014 foi propiciada pelo deslocamento do braquete do primeiro pré-molar fixo à máquina Instron. Foi utilizada célula de carga de 500 Newtons e velocidade de 0,05mm/segundo durante a deformação. As forças e momentos foram registrados até deslocamento máximo de 4,5 mm e durante retorno à zero. Foram realizadas dez repetições para cada modelo de braquete. O registro do binding foi obtido em teste separado por meio da tração contínua do fio Contour NiTi durante deformação de primeira ordem até 4,8 mm e retorno até zero. Os efeitos mecânicos foram comparados com deformação de 4 mm. Resultados: na unidade de movimentação as forças de ativação apresentaram diferenças significantes (Damon 224, Easy Clip 241 e Smart Clip 299 cN) enquanto as forças de desativação foram menores no Damon (62 Cn) e semelhantes entre os braquetes Easy Clip (71 cN) e Smart Clip (76 Cn). Na unidade de ancoragem os momentos de ativação apresentaram diferenças significantes (Damon 314, Easy Clip 356 e Smart Clip 438 cN/mm) enquanto os momentos de desativação foram semelhantes entre os braquetes Damon e Easy Clip (239/242 cN/mm) e significativamente maiores no Smart Clip (317 cN/mm). Os valores de binding na ativação e desativação foram semelhantes. O percentual de histerese das forças foi 70% e dos momentos 28%. Conclusões: 1) as forças de desativação produzidas pelo fio Contour NiTi .014 foram semelhantes, o que indicou equivalência mecânica entre os braquetes Damon, Easy Clip e Smart Clip na unidade de movimentação; 2) os momentos de desativação produzidos pelo fio Contour NiTi .014 foram semelhantes entre os braquetes Damon e Easy Clip, e maiores no Smart Clip, o que indicou equivalência mecânica apenas entre os braquetes Damon e Easy Clip na unidade de ancoragem ; 3) a medição das forças de atrito por meio da tração contínua do fio ortodôntico não se mostrou adequada para medir o binding associado à força de desativação; 4) a histerese acentuada observada no início da desativação das forças foi influenciada pela superelasticidade do fio e pelo binding na unidade de ancoragem. / Bracket characteristics and wire stiffness dictate the mechanical effects that nickel titanium wire deformation will cause upon teeth. The main variables associated to bracket characteristics include bracket length (that influence interbracket distance), and coefficient of friction. The purpose of this research was to compare how self ligated brackets such as Damon, Easy Clip and Smart Clip influence moments, forces, and binding produced by the deformation of a .014 Niti Contour wire. Methods: a clinical simulation device with three .022x.028 stainless steel brackets representing canine and bicuspids was attached to an Instron universal traction machine in order to register the forces, and to a Lutron dynamometer to register the moments produced on the anchor unit. The displacement of the first bicuspid fixed on the Instron machine produced a first order deformation on the superelastic .014 Niti Contour wire. A load cell of 500 Newtons under a speed of 0,05mm/second was used during the deformation. Forces and moments were registered up to 4,5mm maximum displacement and during the return to zero. For each bracket model ten repetitions were performed. Binding registration was obtained on a separate test, by continuous traction of the Contour Niti wire during first order deformation up to 4,8mm and back to zero. The mechanical effects were compared with a 4mm deformation. Results: on the moving unit, the activation forces presented significant differences (Damon 224, Easy Clip 241 and Smart Clip 299cN), while the deactivation forces were smaller on Damon (62cN) and similar on the Easy Clip (71cN) and Smart Clip (76 cN). The activation moments on the anchor unit presented significant differences (Damon 314, Easy Clip 356 and Smart Clip 438 cN/mm), while the deactivation moments were similar in the Damon (239 cN/mm) and Easy Clip (242 cN/mm) brackets, and significantly larger on Smart Clip (317cN/mm). Activation and deactivation binding values were similar. The hysteresis percentage on forces was 70% and on moments 28%. Conclusions: 1) the forces produced by the .014 Contour Niti at the movement unit are similar among the Damon, Easy Clip and Smart Clip brackets; 2) the moments produced by the .014 Contour Niti at the anchor unit are similar between Damon and Easy Clip brackets, while the Smart Clip produces larger moments; 3) the method of measuring friction forces by continuous traction of the orthodontic wire is not adequate to measure the binding associated with deactivation forces; 4) hysteresis observed at the beginning of deactivation is influenced by binding.
162

Avaliação dos efeitos dento-esqueléticos ocorridos após o tratamento da mordida cruzada posterior, com o uso do aparelho expansor fixo tipo quadrihélice /

Pinheiro, Paulo Márcio de Mendonça. January 2003 (has links)
Orientador: Osmar Aparecido Cuoghi / Resumo: Este estudo tem como objetivo avaliar os efeitos dento-esqueléticos decorrentes da correção da mordida cruzada posterior com o aparelho expansor fixo tipo quadrihélice. Foram analisadas telerradiografias em norma frontal póstero-anteriores e modelos de gesso do arco superior de 17 crianças, com média de idade antes do tratamento de 7,5 anos, portadoras de mordida cruzada posterior sem envolvimento esquelético. Os dados foram avaliados em três tempos distintos: Tempo 1 (T1), antes do tratamento; Tempo 2 (T2), após a correção da má oclusão; e Tempo 3 (T3), após três meses de contenção mais 6 meses sem contenção. As medidas transversais nos modelos de gesso mostraram um mesmo padrão, com um aumento entre T1 e T2, uma discreta diminuição entre T2 e T3. A distância inter-segundos molares decíduos apresentou o maior aumento total, seguida pela distância inter-caninos e distância inter-primeiros molares permanentes. As medidas nas telerradiografias mostraram padrões diferentes, e dentre aquelas com diferenças estatisticamente significante, mx'-mx" e ag'-ag" apresentaram aumentos consecutivos entre T1 e T2 e entre T2 e T3 e a medida ms'-ms" mostrou aumento entre T1 e T2 e suave diminuição entre T2 e T3. A medida ii -lsr não apresentou diferença estatisticamente significante. / Abstract: This study aimed to evaluate the dentoskeletal effects consequent to posterior crossbite correction by using quad-helix fixed espansion appliance. It was analysed telerradiographs in frontal norm and maxillary arch dental cast, taken from 17 children, at 7,5 years of average ages before treatment, with dental and/or functional posterior crossbite malocclusion. Data were analysed among three different periods: Period 1 (T1), before treatment; Period 2 (T2), after malocclusion corrections; and Period 3 (T3), after three months of retention and six months out of retention. Transversal measurements of dental casts showed similar pattern, with an increase T1 and T2, and a discrete decrease between T2 and T3. The distance between the second deciduous molars presented the highest increase, followed by deciduous inter-canine distance and the distance between first permanent molars. The cephalometrics measurements showed different patterns, and among those that presented statistically significant differences, mx'-mx" and ag'-ag" increased at both periods T1-T2 and T2-T3, and ms'-ms" increased at period T1-T2 and decreased slightly at period T2-T3. The variable ii -lsr did not present statistically significant difference. / Mestre
163

Estudo comparativo das alterações cefalométricas do tratamento da má oclusão de Classe II com os aparelhos propulsores Jasper Jumper e Forsus Fatigue Resistant Device, associados ao aparelho fixo / Treatment effects produced by the Jasper Jumper vs the Forsus Fatigue Resistant Device, associated with fixed orthodontic appliances, in growing Class II patients

Daniela Cubas Pupulim 29 March 2016 (has links)
Objetivo: O objetivo deste estudo foi comparar as alterações cefalométricas de pacientes com má oclusão de Classe II divisão 1 tratados com os aparelhos Jasper Jumper e Forsus Fatigue Resistant Device, associados ao aparelho ortodôntico fixo. Material e métodos: A amostra foi constituída por 124 telerradiografias em norma lateral de 62 indivíduos, os quais foram divididos em 3 grupos: Grupo Experimental 1 (n=22, idade inicial=12,39 anos), tratados por meio do aparelho Jasper Jumper associado ao aparelho fixo, por um período médio de 2,43 anos; Grupo Experimental 2 (n=19, idade inicial=12,43 anos), tratados com o aparelho Forsus associado ao aparelho fixo, com tempo médio de tratamento de 3,54 anos; Grupo Controle (n=22, idade inicial 12,14 anos), observados por um período médio de 1,78 anos. As alterações de todas as variáveis cefalométricas dos grupos experimentais foram anualizadas e, posteriormente, comparadas às alterações das variáveis do grupo Controle, por meio da Análise de Variância e do teste de Tukey. Resultados: Observou-se que ambos os tratamentos apresentaram um efeito restritivo na maxila; não alteraram o desenvolvimento mandibular; melhoraram a relação maxilomandibular; promoveram rotação horária do plano oclusal e um suave aumento da altura facial anteroinferior. Os grupos experimentais apresentaram limitação do desenvolvimento vertical dos molares superiores; inclinação para vestibular e limitação do desenvolvimento vertical dos incisivos inferiores; e extrusão dos molares inferiores. Os incisivos inferiores exibiram maior protrusão no grupo 1 em relação aos demais grupos. Ambos os aparelhos melhoraram significantemente a relação maxilomandibular, os trespasses horizontal, vertical e a relação molar. Os protocolos de tratamento promoveram retrusão dos lábios superiores. O grupo 2 apresentou suave protrusão dos lábios inferiores e os grupos 1 e 3 apresentaram pequena retrusão. Conclusão: Conclui-se que ambos os aparelhos foram eficazes na correção da má oclusão de Classe II. / Objective: The aim of this study was to compare the cephalometric changes of Class II division 1 malocclusion patients treated with Jasper Jumper and Forsus Fatigue Resistant Device, associated with fixed appliances. Methods: The sample consisted of 124 lateral cephalograms of 62 individuals, divided into 3 groups: Group 1 (n=22,mean age=12.39 years), treated with the Jasper Jumper appliance associated with fixed appliances for a mean period of 2.43 years; Group 2 (n=19, mean age=12.43 years), treated with the Forsus appliance associated with fixed appliances, with a mean treatment time of 3.54 years; and the Control group (n=22, mean age=12.14 years), followed for a mean period of 1.78 years. The changes of all cephalometric variables in the study groups were annualized and then compared to the changes observed for the Control group, by analysis of variance and Tukey test. Results: It was observed that both treatments presented a restrictive effect on the maxila; did not change the mandibular development; improved maxillomandibular relationship; produced clockwise rotation of the occlusal plane; and a slight increase in lower anterior facial height. Study groups showed limitation on the vertical development of the maxillary molars; buccal tipping and limitation on the vertical development of the mandibular incisors; and extrusion of mandibular molars. The mandibular incisors exhibited greater protrusion in the group 1 compared to other groups. Both appliances provided significant improvement of maxillomandibular relationship, overjet, overbite and molar relationship. Treatment protocols promoted retrusion of the upper lip. Group 2 presented mild protrusion of the lower lip and groups 1 and 3 showed mild retrusion. Conclusion: Both the appliances were effective in the treatment of Class II malocclusion.
164

Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos / Assessment of the displacement resistance of overlapped heat-activated superelastic nickel titanium wires in passive self-ligating brackets

Galvão, Mariana de Aguiar Bulhões 22 August 2014 (has links)
Objetivos: O objetivo desta pesquisa foi comparar a resistência ao deslocamento de fios de níquel e titânio superelásticos termoativados sobrepostos, em braquetes ortodônticos metálicos autoligáveis passivos. Material e Métodos: Foram utilizadas três espessuras de fios de níquel e titânio superelásticos termoativados (NiTi-TA): 0,014 sobreposto ao 0,016 e 0,020 (FlexyNiTi Thermal - Orthometric, Marília, SP, BR), associados a dois tipos de braquetes metálicos autoligáveis passivos: SmartClip SL3® (3M Unitek, Monrovia, CA, EUA) e OrthoClip SLB® (Orthometric, Marília, SP, BR). Um dispositivo que continha 5 braquetes de cada tipo (do incisivo central superior direito ao 2º pré-molar superior direito) foi desenvolvido para realização dos testes. O braquete do canino foi colado em uma barra de aço inoxidável móvel que permitia alterar sua posição vertical, enquanto os demais braquetes foram colados a uma barra fixa de acrílico. As forças obtidas por meio do deslocamento vertical do braquete do canino de 0mm para 1,5mm, 3,0 mm, 4,5mm e 6,0 mm foram registradas. O ambiente de teste foi seco com temperatura controlada de 36,5º C ± 1º C. Um total de 160 testes foi realizado na máquina de ensaios universal Instron. Os testes estatísticos de Shapiro-Wilk, teste t de Student não pareado e ANOVA com testes post-hoc de Tukey foram aplicados aos dados (p<0,05). Resultados: A distribuição normal da amostra foi confirmada, e os testes paramétricos demonstraram que houve diferenças estatisticamente significativas no braquete SmartClip SL3® quando associados aos fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 nas alturas de 1,5mm (p=0,003) e 6mm (p0,0001). Porém, não foram encontradas diferenças estatísticas nas alturas de 3mm (p=0,76) e 4,5mm (p=0,09). No braquete OrthoClip SLB® houve diferenças estatisticamente significativas entre os fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 em todas as alturas avaliadas (p0,0001). Na comparação entre os braquetes, quando associados ao fio 0,020 de NiTi-TA houve diferenças estatisticamente significativas na altura de 1,5mm; 3mm e 6mm (p0,0001). No entanto, na altura de 4,5mm as diferenças não foram significativas estatisticamente (p=0,32). Quando associados aos fios de NiTi-TA 0,014 e 0,016 sobrepostos, as diferenças em todas as alturas avaliadas foram significativas estatisticamente (1,5mm - p=0,0006; nas demais alturas p0,0001). Conclusão: Nos braquetes SmartClip SL3®, em desnivelamentos de 1,5mm, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento, enquanto que na altura de 6mm a menor resistência foi obtida com o fio de NiTi-TA 0,020. Nas demais alturas não houve diferenças estatísticas entre os fios. Para os braquetes OrthoClip SLB®, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento em todas as alturas avaliadas. Na comparação entre os dois tipos de braquetes, associados ao fio de NiTi-TA 0,020 na altura de 1,5mm, o braquete OrthoClip SLB® apresentou menor resistência ao deslocamento, ao passo que nas alturas de 3mm e 6mm foi o braquete SmartClip SL3®. Na altura de 4,5mm não foram encontradas diferenças estatisticamente significativas entre os dois braquetes avaliados. / Objective: The objective of this research was to compare the displacement resistance of overlapped heat-activated superelastic nickel titanium wires, in passive self-ligating metallic brackets. Material and Methods: Three thicknesses of heat-activated superelastic nickel titanium wires (NiTi-TA) were used: 0.014 overlapped with 0.016 and 0.020 (FlexyNiTi Thermal - Orthometric, Marília, SP, BR), associated with two types of passive self-ligating metallic brackets: SmartClip SL3® (3M Unitek, Monrovia, CA, EUA) and OrthoClip SLB® (Orthometric, Marília, SP, BR). A device with 5 brackets of each type (from right central incisor to the second maxillary premolar) was developed for this research. The canine bracket was attached to a sliding stainless steel bar which allowed the alteration of its vertical position, while the remaining brackets were attached to a fixed acrylic bar. The forces generated by means of the canine bracket vertical displacement from 0mm to 1.5mm; 3.0mm; 4.5mm and 6.0mm were recorded. The test environment was dry with a controlled temperature of 36.5º C ± 1º C. A total of 160 tests were carried out in the Instron Testing Machine. The Shapiro-Wilk test, non-paired Student t-test and ANOVA with Tukey post hoc test were applied to the data (p<0.05). Results: The normal distribution was confirmed, and the parametric tests showed that there were statistically significant differences in the SmartClip SL3® when associated with the NiTi-TA 0.020 and 0.014 wires overlapped to the 0.016 wire in the height of 1.5mm (p=0.003) and 6mm (p<0.0001). However, statistically significant differences were not found in the heights of 3mm (p=0.76) and 4.5mm (p=0.09). For the OrthoClip SLB® brackets, there were statistically significant differences between the NiTi-TA 0.020 and 0.014 wires overlapped with the 0.016 wire in all the heights assessed (p<0.0001). In the comparison between the brackets when associated with the NiTi-TA 0.020 wire, there were statistically significant differences in the heights of 1.5mm, 3mm and 6mm (p<0.0001). However, in the height of 4.5mm the differences were not statistically significant (p=0.32). When associated with the overlapped NiTi-TA 0.014 and 0.016 wires, the differences in all assessed heights were statistically significant (1.5mm - p=0.0006; other height - p0.0001). Conclusion: For the SmartClip SL3® brackets, with 1.5mm of displacement, the overlapped NiTi-TA 0.014 and 0.016 wires showed less displacement resistance, while in the height of 6mm the least displacement resistance was found with the NiTi-TA 0.020. In the remaining heights, there were no statistically significant differences between the wires. For the OrthoClip SLB® brackets, the overlapped NiTi-TA 0.014 and 0.016 wires showed the least displacement resistance in all the assessed heights. In the comparison between the two types of brackets, associated with the NiTi-TA 0.020 wire, for the height of 1.5mm, the OrthoClip SLB® bracket showed less displacement resistance, while for the heights of 3mm and 6mm the SmartClip SL3® brackets showed less displacement resistance. For the height of 4.5mm there were no statistically significant differences found between the assessed brackets.
165

Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd /

Penido, Sérgio Milton Martins de Oliveira. January 2006 (has links)
Orientador: Ary dos Santos-Pinto / Banca: Vânia Célia Vieira de Siqueira / Banca: Rodrigo de Castro Albuquerque / Banca: Lídia Parsekian Martins / Banca: Luiz Gonzaga Gandini Júnior / Resumo: Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / Abstract: This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure. / Doutor
166

Análise comparativa in vitro da resistência friccional entre braquetes metálicos e estéticos / Friction resistance among stainless steel brackets and aesthetic brackets: an in vitro study

Rodrigues, Kelly Regina Thomé Portugal 04 October 2011 (has links)
Made available in DSpace on 2016-08-03T16:30:57Z (GMT). No. of bitstreams: 1 RESUMO - Kelly Portugal Rodrigues.pdf: 90584 bytes, checksum: a9009d09309f76e094fc03b33ceabe30 (MD5) Previous issue date: 2011-10-04 / The aim of this in vitro study was to compare the friction resistance among conventional and aesthetic orthodontic brackets with metal and vitreous slot with round and rectangular wires of different sections, simulating some situations without wire displacement, 2 mm of displacement and binding of 3o. A group of 125 brackets from 5 brands (Roth Standard, Composite, Elation, Invu and Radiance) was tested, 25 brackets for each brand. Five brackets were set on a device in order to simulate a top right hemi-arch (lateral and central incisors, canine, first and second premolars) and after that, the device was coupled on an universal testing machine EMIC DL2000. The archwires 0.016 , 0.018 and 0.017 x 0.025 NiTi were used on the no displacement and 2 mm displacement tests, while the wires 0.017 x 0.025 , 0.019 x 0.025 and 0.021 x 0.025 stainless steel were used to simulate the binding effect. Variance analysis and Tukey tests (p<0,05) were run to compare brackets with different archwires sizes and angulation. The study demonstrated that the polycarbonate aesthetic bracket Composite had the least friction in all archwires sizes tested. On the other hand, the monocrystalline ceramic bracket Radiance showed the greatest frictional resistance on the tests without wire displacement. Studies with archwire displacement and binding showed a statistically significant difference between the five accessories, of which Composite, Roth Standard, Elation, Invu and Radiance produced the highest friction resistance, in increasing order. Moreover, the insertion of a metal slot in the polycarbonate bracket Elation significantly reduced the friction. However, these friction was greater than the one from a metal bracket. To sum up, the insertion of a vitreous slot in the polycrystalline ceramic bracket Invu offered a greater surface smoothness, reducing consequently the friction and favoring the displacement. / O presente estudo visou comparar in vitro o atrito produzido por braquetes convencionais metálicos e estéticos com canaleta metálica e vítrea quando inseridos fios de secções redonda e retangular de diferentes dimensões, simulando situações sem deslocamento, com deslocamento de 2 mm e com simulação do efeito binding 3º. Foram utilizados 125 braquetes de 5 marcas comerciais (Roth Standard, Composite, Elation, Invu e Radiance), sendo 25 braquetes para cada corpo de prova. Para os ensaios laboratoriais, foram colados 5 braquetes simulando uma hemi-arcada superior direita (incisivos central e lateral, canino, primeiro e segundo premolares) em um dispositivo para posicionamento dos braquetes, sendo este acoplado à máquina universal de ensaios EMIC DL2000. Foram empregados os fios 0,016 , 0,018 e 0,017 x 0,025 NiTi para realização dos ensaios sem deslocamento e com deslocamento de 2 mm e os fios de secção 0,017 x 0,025 , 0,019 x 0,025 e 0,021 x 0,025 CrNi para realização dos ensaios com angulação zero grau e 3º. Para a comparação entre os braquetes nos diferentes fios e angulações, foi utilizada a Análise de Variância e o teste de Tukey (p<0,05). Os resultados demonstraram que nos ensaios sem deslocamento o braquete estético de policarbonato Composite apresentou menor atrito em todos os fios avaliados, enquanto o maior atrito em todas as combinações realizadas foi observado no braquete estético cerâmico monocristalino Radiance em relação aos demais braquetes. Nos ensaios com deslocamento de 2 mm e simulação do efeito binding 3º, os resultados foram semelhantes aos observados nos ensaios sem deslocamento. Contudo, houve uma diferença estatisticamente significante entre os cinco corpos de prova, sendo o atrito verificado, respectivamente e de forma crescente, nos braquetes Composite, Roth Standard, Elation, Invu e Radiance. Pôde-se concluir que a resistência friccional teve influência da composição dos braquetes, diâmetro dos fios e tipo de ensaio realizado (deslocamento de 2 mm e angulação de 3º). Além disso, a inserção da canaleta metálica no braquete estético de policarbonato Elation reduziu de forma estatisticamente significante o atrito, porém esse foi maior do que o gerado por um braquete convencional metálico e, por fim, a incorporação da canaleta vítrea no braquete estético cerâmico policristalino Invu ofereceu uma maior lisura de superfície, reduzindo as irregularidades e imperfeições presentes na canaleta o que levou, consequentemente, a uma redução estatisticamente significante no atrito, o que demonstra que a modificação em sua canaleta favoreceu o deslocamento e reduziu de forma efetiva essa resistência à fricção.
167

Estudo da resistência às forças de cisalhamento de três sistemas condicionantes indicados para a colagem de acessórios ortodônticos

Bertoz, André Pinheiro de Magalhães [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T20:36:31Z : No. of bitstreams: 1 bertoz_apm_me_araca.pdf: 3969582 bytes, checksum: bceb452a18ac260c5d9321687a89fc4b (MD5) / Os recentes materiais de colagem dos acessórios ortodônticos têm visado reduzir o tempo de trabalho do clínico, simplificando o procedimento do condicionamento ácido por meio dos sistemas adesivos autocondicionantes. Todavia, as qualidades adesivas desses materiais ainda demandam ser avaliada. Assim, o presente estudo objetivou avaliar a resistência às forças de compressão de três sistemas adesivos. Cento e oitenta incisivos inferiores bovinos foram seccionados e incluídos em matrizes de resina acrílica, nos quais acessórios ortodônticos foram colados com os sistemas Transbond XT (2 grupos de 30), Transbond XT Plus Self Etching Primer (2 grupos de 30) e Tyrian (2 grupos de 30). Para cada sistema, os testes de resistência foram realizados imediatamente (30 dentes) e 24 horas (30 dentes) após a colagem, em uma máquina de ensaio Versat 2000 (Pantec), utilizando célula de carga de 500 Kgf com uma velocidade de 1mm/minuto, de acordo com a literatura. Os sistemas convencional Transbond XT, Transbond XT Self Etching Primer e Tyrian apresentaram, respectivamente, valor médio de resistência à compressão de 7,43, 7,09 e 3,41 MPa no tempo imediatamente após a colagem, e 7,42, 8,81, 5,35 MPa no tempo 24 horas após a colagem, sendo as diferenças estatísticas significantes ao nível de 5% entre os grupos Tyrian e Transbond para ambos os tempos de estudo. Concluiu-se que o material Tyrian apresentou resistência à compressão significativamente inferior em relação aos grupos Transbond que foram similares. / Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.
168

Análise de elementos finitos da distalização do primeiro molar superior com barra transpalatina ancorada em microparafusos ortodônticos

Dobranszki, Adriano 14 November 2014 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2015-01-29T14:43:44Z No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2015-02-10T18:12:36Z (GMT) No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / Made available in DSpace on 2015-02-10T18:12:36Z (GMT). No. of bitstreams: 1 2014_AdrianoDobranski.pdf: 8250201 bytes, checksum: 497c274b9280d6e7ca82328a99054db3 (MD5) / O objetivo deste estudo foi avaliar, por meio de análise de elementos finitos, a distribuição de tensões em um primeiro molar superior, após aplicação de força de distalização em uma barra transpalatina (BTP) presa ao molar e ancorada em microparafusos ortodônticos (MPO) instalados em diferentes locais do palato e sugerir a indicação clínica para cada tipo de ativação. Tendo como fonte um banco de dados de tomografias volumétricas, medidas foram feitas e submetidas a análise estatística para criação de um modelo virtual válido de uma maxila humana de um indivíduo portador de relação maxilomandibular de Classe II esquelética típico. Este modelo foi utilizado como base para uma análise combinatória de 3 locais de instalação do MPO (2, 5 e 8 mm) e 3 pontos de ativação na BTP: próximo ao tubo lingual, na metade do comprimento do braço da barra e próximo ao ômega central, resultando em 9 modelos analisados com o programa ANSYS, cada um com aproximadamente 500.000 elementos tetraédricos. Imediatamente após aplicação de carga de 1,5 N na BTP, os valores do deslocamento inicial da trifurcação do molar e da rotação da coroa foram tabulados. Os resultados sugeriram que mudanças na posição de instalação do MPO e do ponto de ativação na BTP produziram diferentes efeitos na movimentação do primeiro molar superior, no sentido A-P, vertical e na rotação (angulação). Com os dados do modelo preliminar, concluiu-se que a maior concentração de tensões na BTP foi localizada na dobra próxima à entrada do tubo lingual, indicando o ponto de maior propensão à falha; no MPO, foi localizada na região do pescoço próximo à transição do perfil transmucoso para as espiras, região em contato com a borda externa do osso cortical palatino, indicando o ponto de maior propensão à falha; no osso cortical palatino, foi localizada na borda externa, mesial ao microparafuso, indicando o ponto em que provavelmente ocorreria maior demanda biológica inflamatória. No modelo definitivo, a ativação “2 mm apical”, próxima ao ômega central da BTP, foi a única que resultou em efeito extrusivo, com deslocamento mesial da coroa e distal das raízes e furca, ativação sugerida para distalização com aumento da dimensão vertical, por extrusão do molar. A ativação “2 mm cervical”, próxima ao tubo lingual do molar, resultou em um efeito leve de intrusão, distalização e acentuado giro distal da coroa, ativação sugerida para distalização quando o molar encontra-se mésioangulado. A ativação “5 mm média”, na metade do comprimento do braço da BTP, resultou em giro distal da coroa e leve movimento intrusivo, ativação sugerida quando o molar encontra-se com leve mesioangulação e ligeiramente extruído, ou quando se deseja distalizar fechando levemente a mordida anterior. A ativação “8 mm médio” produziu pouco efeito de distalização e pouco giro distal da coroa, sugerida quando se deseja pouca distalização com intrusão quase pura do molar, com angulação distal da coroa. A ativação “8 mm apical” produziu muito pouca distalização e acentuada intrusão e angulação distal da coroa, sugerida quando se deseja intruir o molar. ________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate by finite element analysis the stress distribution in a maxillary first molar after application of a distalization force on a transpalatal arch (TPA) attached to the molar and anchored on orthodontic microscrews (OMS) in different locations of the palate and suggest the clinical indication for each type of activation. Having as source a database of volumetric scans, measurements were made and subjected to statistical analysis to create a valid virtual model of a typical skeletal Class II maxillo-mandibular relationship individual. This virtual maxillary model was used as the basis for a combinatorial analysis of 3 OMS installation positions (2, 5 and 8 mm) and 3 TPA activation positions (near the lingual tube, in the half length of the bar arm and near the central omega, resulting in 9 models analyzed using ANSYS program, each with approximately 500.000 tetrahedral elements. Immediately after application of load of 1.5 N in the BTP, the values of the initial displacement of the trifurcation and of the rotation of the molar crown were tabulated. The results suggested that changes in the position of installation and OMS activation point of the TPA produced different effects on the movement of the upper first molar in the A-P and vertical directions and rotation (angle). With the data of the preliminary study it was concluded that the highest stress concentration on the TPA was located at the bend next to the entrance of the lingual tube, indicating the point of higher propensity to failure; on the OMS, it was located at the neck, near to the transition from the transmucosal profile for the thread, site in contact with the external edge of the palatal cortical bone, indicating the point of higher propensity to failure; on the palatal cortical bone, it was located at the external edge, mesial to the OMS, indicating the point where most likely would occur a higher inflammatory biological demand. In the definitive model, the "2 mm apical" activation, next to the central omega of the TPA, was the only activation that resulted in extrusive effect, with mesial displacement of the crown and distal displacement of the roots and of the furcation, suggested activation for distalization with increase of the vertical dimension, by molar extrusion. The "2 mm cervical" activation, next to the molar lingual tube, resulted in a light intrusive effect, distalization and marked crown distal rotation, activation suggested for distalization when the molar is angle to the mesial. The "5 mm activation", at the half of the TPA arm´s lenght, resulted in distal rotation of the crown and light intrusive movement, activation suggested when the molar is slightly angled to the mesial and slightly extruded, or when it is desired to distalize and close the anterior bite slightly. The "8 mm medium" activation produced little effect to the distalization and a slightly distal rotation of the crown, suggested when a slight distalization it is desirable, with almost pure intrusion of the molar with distal angulation of the crown. The "8 mm apical" activation produced very little effect on the distalization and a marked intrusion with distal angulation of the crown, suggested when it is desired to intrude the molar.
169

Avaliação da resistência de união de tubos ortodônticos submetidos a diferentes protocolos de colagem / Evaluation of bond strength of molar orthodontic tubes subjected to different bonding protocols

Jardim, Alexandre Fausto da Veiga 02 February 2018 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-05-08T18:50:19Z No. of bitstreams: 2 Dissertação - Alexandre Fausto da Veiga Jardim - 2018.pdf: 1979763 bytes, checksum: 0ef0698dbb58bc9423f5f8c180f2c6a6 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-05-09T11:29:00Z (GMT) No. of bitstreams: 2 Dissertação - Alexandre Fausto da Veiga Jardim - 2018.pdf: 1979763 bytes, checksum: 0ef0698dbb58bc9423f5f8c180f2c6a6 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-09T11:29:00Z (GMT). No. of bitstreams: 2 Dissertação - Alexandre Fausto da Veiga Jardim - 2018.pdf: 1979763 bytes, checksum: 0ef0698dbb58bc9423f5f8c180f2c6a6 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-02-02 / Objective: Evaluate the shear bond strength of the union of orthodontic tubes bonded to molar teeth with different bonding protocols. Material and Method: One hundred and twenty molar teeth, previously extracted from patients with age between 12 and 30 years were selected. Orthodontic molar tubes were bonded on the vestibular surface of these teeth with one of two types of adhesive (Transbond XT or Orthobond). Each of these groups were subsequently divided in 4 other groups: control and with the use of a resin reinforcement on the occlusal surface of the bonded tubes with one of three materials (Transbond XT, Tetric N Flow, Z 350 Flow). Shear bond strength and adhesive remnant index tests were performed to evaluate the bond strength and type of fracture of the tubes bonded with the different methods. Results: Tubes bonded with Transbond XT had superior bond strength than tubes bonded with Orthobond. The use of resin reinforcement with Transbond XT increased significantly the shear bond strength of tubes bonded with Transbond XT. All groups presented in most of their samples less than 50% of adhesive remnant in the vestibular surface after de shear bond test. Conclusion: The use of a resin reinforcement with Transbond XT increased the shear bond strength of orthodontic tubes bonded with Transbond XT. / Objetivo: Avaliar a resistência de união de tubos ortodônticos colados em molares com diferentes protocolos de colagem. Material e Método: Foram selecionados 120 molares humanos com coroas hígidas, previamente extraídos de pacientes com idade entre 12 e 30 anos. Tubos ortodônticos foram colados na superfície vestibular destes dentes com um de dois tipos de resinas (Transbond XT ou Orthobond). Cada grupo colado com um dos materiais foi subsequentemente dividido em 4 grupos: controle e com aplicação de um reforço de resina na superfície oclusal dos tubos com um de três materiais (Transbond XT, Tetric N Flow, Z 350 Flow). Testes de cisalhamento e de remanescente adesivo foram executados para avaliar a resistência e tipo de fratura dos tubos submetidos aos diferentes protocolos de colagem. Resultados: Tubos colados com a resina Transbond XT apresentaram resistência superior aos tubos colados com resina Orthobond. O uso de reforço resinoso com a resina Transbond XT aumentou de maneira significativa a resistência dos tubos ortodônticos colados com resina Transbond XT. O uso de resinas do tipo flow como reforço resinoso não resultou em aumento significativo da resistência ao cisalhamento. Todos os grupos em sua maioria apresentaram menos de 50% de remanescente resinoso na superfície vestibular após a fratura. Conclusão: O uso de um reforço resinoso com resina Transbond XT aumenta a resistência ao cisalhamento de tubos ortodônticos colados com resina Transbond XT.
170

Adição de monômero com função quaternária de amônio em adesivos experimentais para colagem de bráquetes metálicos : desenvolvimento de lesão cariosa e resistência de união após desafio cariogênico

Nascimento, Patrícia Layane de Menezes Macêdo 03 February 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Incipient carious lesions manifested by white spots are frequently visualized around the orthodontic brackets. Further to possible progression of these lesions to cavities, a reduction on the bond strength of the bracket to the tooth enamel might occur due to mineral loss. Adhesive systems containing monomers that inhibits the bacteria adhesion or activity have been developed to help at caries control around of brackets. This study evaluated the caries inhibition and shear bond strength reached by addition of antibacterial monomer 2-(Methacryloyloxy)ethyl]trimethylammonium chloride (MADQUAT) to adhesive used to cement orthodontic brackets when submitted to cariogenic challenge. Sound premolars were sectioned in halves and brackets are cemented to the buccal and lingual surfaces using experimental adhesives with 0 (control), 5 or 10% of MADQUAT. Half of the samples was subjected to cariogenic challenge using a microcosm biofilm model with intermittent exposure to sucrose for 6 hours per day during 5 days. Following, the samples were embedded in resin cylinders and brackets submitted to shear loading until the de-bonding. The mode failure was analyzed under optical microscopy. The tested samples were sectioned and the internal enamel hardness measured to calculate the integrated mineral loss (ΔS). Data of bond strength and ΔS were submitted to two-way ANOVA and Tukey test, while the chi-square test was used to assess the effect of factors on failure mode (α = 0.05). The adhesive containing 10% of MADQUAT significantly reduced the demineralization around the bracket, but also reached lowest bond strength values. No effect on the bond strength and ΔS was observed by addition of 5% MADQUAT to adhesive. The cariogenic challenge did not affect the bond strength and the failure mode, which was influenced only by the adhesive. It was concluded that the MADQUAT was only effective to reduce demineralization when added to the adhesive at a concentration of 10%, whereas this concentration also reduced the bond strength. / Lesões cariosas incipientes, manifestadas por meio de manchas brancas, são comumente visualizadas ao redor dos bráquetes. Além destas lesões poderem progredir para cavidades, uma redução na resistência de união do bráquete ao esmalte dental pode ocorrer devido à perda mineral. Sistemas adesivos contendo monômeros que inibem a adesão ou atividade bacteriana têm sido desenvolvidos para auxiliar no controle de cárie ao redor dos bráquetes. Este estudo avaliou a inibição de cárie e a resistência de união alcançado pela adição do monômero antibacteriano [2 - (metacriloxi) etil] trimetil cloreto de amônio (MADQUAT) ao adesivo usado para colagem de bráquetes ortodônticos quando submetidos ao desafio cariogênico. Para isto, foram utilizados trinta pré-molares hígidos, seccionados ao meio. Bráquetes foram colados nas faces vestibular e lingual usando adesivos experimentais com 0% (controle), 5% ou 10% de MADQUAT. Metade das amostras foram submetidas ao desafio cariogênico em modelo de biofilme com microcosmos, com exposição intermitente a sacarose por 6 horas por dia, durante 5 dias. Em seguida, as amostras foram embutidas em cilindros de resina e os bráquetes submetidos ao carregamento de cisalhamento até ruptura. O padrão de falha foi analisado em microscopia óptica. As amostras ensaiadas foram seccionadas ao meio e a dureza interna do esmalte mensurada para calcular a perda mineral integrada (ΔS). Os dados de resistência de união e ΔS foram submetidos à ANOVA de duas vias e teste de Tukey, enquanto queo teste Qui-quadrado foi usado para avaliar o efeito dos fatores no padrão de falha (α = 0,05). O adesivo contendo 10% de MADQUAT reduziu significativamente a desmineralização ao redor do bráquete, porém alcançou menores valores de resistência de união. Nenhum efeito na resistência de união e na ΔS foi observado com a adição de 5% de MADQUAT ao adesivo. O desafio cariogênico não afetou a resistência de união e o padrão de falha, o qual foi influenciado pelo adesivo. Concluiu-se que o MADQUAT apenas foi eficaz na redução da desmineralização quando adicionado ao adesivo para uma concentração de 10%, mas esta concentração também reduziu a resistência de união.

Page generated in 0.085 seconds