• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 92
  • 39
  • 15
  • 7
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • Tagged with
  • 175
  • 175
  • 41
  • 40
  • 39
  • 38
  • 36
  • 30
  • 27
  • 19
  • 19
  • 17
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Predição do resultado perinatal em gestações trigemelares / Prediction of perinatal outcome in triplet pregnancies

Maia, Carolina Bastos 11 June 2014 (has links)
O presente estudo tem como objetivo descrever a mortalidade perinatal em gestações trigemelares, e analisar os fatores preditores dos seguintes desfechos: número de crianças vivas no momento da alta hospitalar, nenhuma criança viva no momento da alta hospitalar (desfavorável) e pelo menos uma criança viva no momento da alta hospitalar (favorável). Realizado de forma retrospectiva, envolveu pacientes com gestações trigemelares que apresentavam três fetos vivos na primeira ultrassonografia realizada após 11 semanas, no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP), no período de 1998 a 2012. Foram incluídas 67 pacientes das quais 77,6% referiam concepção espontânea. Quanto à corionicidade, 49,2% eram tricoriônicas e 50,8% eram não tricoriônicas; 16,4% apresentavam antecedente clínico prévio à gestação e 49,2% eram nulíparas. Em relação às intercorrências, a incidência de complicações obstétricas e/ou clínicas na gestação foi de 52,2%, e de intercorrências fetais, 25,2%, dentre as quais: 13,4% mal formações, 7,5% sindrome da transfusão feto fetal (STFF), 5,9% óbito fetal (OF), 4,5% insuficiência placentária, 4,4% fetos unidos, 1,5% feto acárdico. A idade gestacional média do parto foi de 31,9 ± 3,1 semanas, dos quais 83,5% foram cesáreas. O peso médio dos recém-nascidos vivos de 1.683 ± 508 g. Em relação à discordância de peso ao nascer: 57% apresentaram até 20%, 23,2% entre 20 e 30% e 19,6% acima de 30%. A taxa de óbitos fetais foi de 31,7%o nascimentos (IC95%: 11,7 - 67,8) e a mortalidade perinatal 249%o nascimentos (IC95%: 189 - 317). O tempo médio de internação dos recém-nascidos, que foram de alta vivos, foi de 29,3 ± 24,7 dias. A predição dos desfechos foi investigada por meio de regressão logística \"stepwise\", e incluiu as seguintes variáveis: idade materna, paridade (nulípara ou um ou mais partos anteriores), antecedente clínico, idade gestacional do primeiro ultrassonografia no HCFMUSP, corionicidade (gestações tricoriônicas e gestações não tricoriônicas), presença de complicação obstétrica ou clínica durante a gestação, intercorrência fetal e idade gestacional do parto. O nível de significância estatística utilizado foi de 0,005. Foram fatores significativos para predição do número de crianças vivas no momento da alta hospitalar: presença de intercorrência fetal (OR 0,1, IC95%: 0,03 - 0,36; p < 0,001) e idade gestacional do parto (OR 1,55, IC95%: 1,31-1,85; p < 0,001). Para a predição dos desfechos favoráveis e desfavoráveis a idade gestacional do parto apresentou significância estatística (OR 1,84, IC95%: 1.26 - 2.7; p=0,002 e OR 0.54, IC 95%: 0.37-0.79; p=0.002, respectivamente) / The present study, involving triplet pregnancies, describes perinatal mortality and investigates predictors of the following outcomes: number of children alive, no child alive (unfavorable outcome) and at least one child alive (favorable outcome) at hospital discharge. It is a retrospective study involving triplet pregnancies with live fetuses at the first ultrasound scan, performed after 11 weeks of gestation, at the Department of Obstetrics and Gynecology, São Paulo University Medical School Hospital, between 1998 and 2012. Final sample included 67 women, 77.6% reported spontaneous conception. Regarding the chorionicity, 49.2% were trichorionic; 16.4% had a medical complication prior to pregnancy, and 49.2% were nulliparous. The incidence of obstetric and/or clinical complications during pregnancy was 52.2%, and fetal complications occurred in 25.2%, (13.4% of major fetal abnormalities, 7.5% twin-to-twin transfusion syndrome, 5.9% stillbirth, 4.5% placental insufficiency, 4.4% conjoined twins and 1.5% acardic twin). The average gestational age at delivery was 31.9 ± 3.1 weeks, and 83.5% were cesarean. The average birthweight was 1683 ± 508 g and birth weight discordance up to 20% occurred in 57% of the cases; 23,2% had 20 to 30% discordance and 19.6%, was greater than 30%. The rate of stillbirth was 31.7%o births (95%CI: 11.7 - 67.8) and the perinatal mortality was 249%o births (95%CI: 189 - 317). The average hospital stay was 29.3 ± 24.7 days amongst children that were discharged alive. Stepwise logistic regression analysis was used to investigate prediction according to: maternal age, parity (nuliparous/multiparous), prior clinical history, gestational age at the first ultrasound scan at HCFMUSP, pregnancy chorionicity (trichorionic/non trichorionic), occurrence of clinical and/or obstetric complications during pregnancy, occurrence of fetal complications and gestational age at delivery. Significance level was set at 0.05. The number of children alive at hospital discharge was correlated with the occurrence of fetal complications (OR 0,1, 95%IC: 0,03 - 0,36; p < 0,001) and gestational age at delivery (OR 1,55, IC95%: 1,31-1,85; p < 0,001). Whereas favorable and unfavorable outcome were associated with gestational age at delivery (OR 1.84, 95%CI: 1.26 - 2.7-; p=0,002 and OR 0.54, 95%CI: 0.37-0.79; p=0.002, respectively)
152

Óbito fetal em gestações únicas com diagnóstico de trissomias dos cromossomos 21,18 13 e monossomia do X / Intrauterine death in pregnancies with trisomy 21, 18, 13 and X monosomy

Goulart, Vanessa Vigna 10 September 2014 (has links)
Objetivos: Descrever a frequência, e investigar fatores preditivos, de óbito fetal espontâneo (OF), em gestações com anomalias cromossômicas. Métodos: Trata-se de estudo retrospectivo, abrangendo o período de novembro de 2004 a maio de 2012, realizado na Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. Foram incluídas gestações únicas com diagnóstico pré-natal de trissomia dos cromossomos 21 (T21), 18, 13 (T13/18) e monossomia do X (45X), realizado até a 26ª semana de gestação. Resultados: Foram incluídas 92 gestantes com idade materna média de 32,7 ± 8,7 anos. O diagnóstico das anomalias cromossômicas (T21 n=36, T13/T18 n=25, 45X n=31) foi realizado em idade gestacional média de 18,3 ± 3,7 semanas, por meio de biópsia de vilo corial (n=22, 24%), amniocentese (n=66, 72%) e cordocentese (n=4, 4%). Malformação major estava presente em 45 (49%); e hidropisia foi identificada em 32 (35%) fetos, sendo mais frequente no grupo 45X (n=24/31 (77%) versus T21: n=6/36 (17%) e T13/18: n=2/25 (8%), p < 0,001). Exame ecocardiográfico fetal especializado foi realizado em 60% (55/92) das gestações. Dessas, 60% (33/55) apresentaram alterações na morfologia e/ou função cardíaca, sendo o achado mais frequente a comunicação interventricular (39%). Fetos com T13/18 apresentaram incidência maior de anomalias cardíacas (60% versus 25% (T21) e 29% (45X), p= 0,01). Óbito fetal ocorreu em 55 (60%) gestações e foi mais frequente no grupo 45X (n=26/31 (84%) versus T21: n=13/36 (36%) e T13/18: n=16/25 (64%), p < 0,01). A análise multivariada stepwise demonstrou associação entre hidropisia e OF em fetos com trissomia 21 (LR= 4,29; IC95%= 1,9-8,0, p< 0,0001). Em fetos com monossomia X, a presença de alterações ecocardiográficas esteve associada com menor risco de OF (LR= 0,56; IC95% = 0,27-0,85, p= 0,005). Não foram identificados fatores preditores no grupo T13/18. Conclusão: A letalidade intrauterina de fetos com anomalias cromossômicas é elevada. A presença de hidropisia aumenta o risco de óbito fetal, em gestações com trissomia 21. Enquanto, em gestações com monossomia X, a ocorrência de alterações ecocardiográficas reduz esse risco / Objectives: To describe the frequency, and associated factors, of intrauterine fetal death (IUD), in pregnancies with chromosomal abnormality. Methods: This was a retrospective (November 2004 to May 2012) performed at de department of obstetrics, Hospital das Clínicas, São Paulo University Medical School. Inclusion criteria were: singleton pregnancies with prenatal diagnosis of trisomy 21 (T21), 18, 13 (T13/18) and X monosomy (45X), performed up to 26 weeks gestation. Results: 92 women were included in the study with a mean maternal age of 32.7 ± 8.7 years. Fetal chromosomal abnormalities (T21 n=36, T13/T18 n=25, 45X n=31) were diagnosed at a mean gestational age of 18.3 ± 3.7 weeks, by chorionic villus sampling (n=22, 24%), amniocentesis (n=66, 72%) and cordocentesis (n=4, 4%). Major fetal structural abnormality was present in 45 (49%) cases; hydrops was diagnosed in 32 (35%) fetuses, and was more common in 45X group (n=24/31 (77%) versus T21: n=6/36 (17%) and T13/18: n=2/25 (8%), p < 0.001). Specialist fetal echocardiography was performed in 55 (60%) pregnancies and showed structural and/or functional abnormalities in 33 (60%) fetuses; ventricular septal defect was the most common finding (39%). T13/18 fetuses showed a higher incidence of cardiac abnormalities (60% versus 25% (T21) and 29% (45X), p= 0.01). IUD occurred in 55 (60%) pregnancies and was more common in 45X group (n=26/31 (84%) versus T21: n=13/36 (36%) and T13/18: n=16/25 (64%), p < 0.01). Stepwise logistic regression analysis demonstrated an association between hydrops and IUD in T21 pregnancies (LR= 4.29; 95%CI= 1.9-8.0, p < 0.0001). In 45X pregnancies, cardiac abnormalities were associated with a lower risk of IUD (LR= 0.56; 95%CI = 0.27-0.85, p= 0.005). No predictors of IUD were identified in T13/18 group. Conclusion: Intrauterine death rate is high in pregnancies with a fetal chromosomal abnormality. Presence of hydrops increases the risk of this complication in trisomy 21 fetuses. Whereas the presence of a cardiac abnormality is protective in X monosomy pregnancies
153

Lymphatische Malformationen im Kindesalter unter besonderer Berücksichtigung von Prognose und Spätergebnissen

Giese, Dina 28 November 2005 (has links)
In einer retrospektiven Studie über den Zeitraum von 1990-2000 wurden in der Klinik für Kinderchirurgie des Universitätsklinikums Charité, Berlin die Kinder untersucht, bei denen eine lymphatische Malformation aufgetreten war. Es ergaben sich insgesamt 18 Patienten. Parallel wurden aus der Klinik für Gynäkologie und Geburtshilfe, Abteilung für Pränatale Diagnostik und Therapie des Universitätsklinikums Charité, Berlin retrospektiv für den oben genannten Zeitraum 31 Patientinnen untersucht, bei deren Feten ein zystisches Nackenhygrom im Verlauf der Schwangerschaft diagnostiziert worden war. Ziel der Arbeit war es, die geeigneteste Therapieform in der Behandlung von lymphatischen Malformationen im Kindesalter in besonderen Hinsicht auf die Prognose, Rezidivfreiheit und Spätergebnisse zu untersuchen. Parallel galt es zu evaluieren, ob in Anbetracht der pränatalen Diagnostizierbarkeit lympahtischer Malformationen und dem postnatal sich daraus ergebenden Krankheitsverlauf eine Schwangerschaftsunterbrechung in Erwägung gezogen werden sollte. / A ten year retrospective study of 18 children with lymphatic malformation and 31 pregnant women with fetal cystic hygromas was carried out at the Department of Pediatric Surgery and the Department of Obstetrics and Gynaecology at the University Hospital Charité, Berlin. The objective of this study was to analyze the most effective therapy for lymphatic malformation in children with regard to the children prognosis, the recurrences after treatment and the long-time-follow-up. Another object to analyze was the point of prenatal diagnosis of fetal cystic hygromas and the adverse fetal outcome.
154

Die Bedeutung der pränatalen Erkennbarkeit obstruktiver Harnwegsfehlbildungen für Diagnostik, Therapie und Prognose aus kinderchirurgischer Sicht

Eckoldt, Felicitas 22 October 2004 (has links)
Einleitung: Fehlbildungen der Nieren und ableitenden Harnwege gehören zu den häufigsten angeborenen Anomalien. Ihr Anteil an den pränatal diagnostizierten Fehlbildungen wird mit bis zu 50% angegeben. Die Behandlung urogenitaler Fehlbildungen hat sich nicht zuletzt unter dem Einfluss der Pränatalen Diagnostik erheblich gewandelt. Nach einer Phase der Übertherapie nach Einführung der pränatalen Diagnostik ergab sich nach modernen diagnostischen Kriterien und im Ergebnis von Langzeitstudien des natürlichen Ganges der Fehlbildungen eine wesentlich differenziertere Indikationsstellung für das aktive therapeutische Vorgehen Fragestellung: In der retro- und prospektiv angelegten Studie sollte untersucht werden, inwieweit die pränatale Diagnostik das postnatale Vorgehen beeinflusst. So sollte untersucht werden, aus welchen pränatalen Befunden welche pränatalen Verdachtsdiagnosen gestellt wurden und wie sich diese zu den definitiven postnatalen Diagnosen verhalten. Des weiteren sollte der Aussagewert einzelner pränataler Befunde herausgearbeitet werden. Besondere Beachtung sollte dabei die Frage finden, inwieweit aus den pränatalen Befunden eine Aussage über die postnatale Therapiebedürftigkeit und schließlich auch für die Prognose der Nierenfunktion möglich ist. Patienten und Methoden: Ausgangspunkt waren 21.616 in der Abteilung für pränatale Diagnostik und Therapie in der Zeit von 1984 bis 1996 untersuchte Schwangerschaften. Unter diesen fanden sich 1.574 Feten mit angeborenen Anomalien mit fraglich kinderchirurgischer Relevanz. 1077 Fälle konnten ausgewertet werden. Mit 990 Fällen dominierten die Fehlbildungen des Urogenitalsystems, von denen 693 in die komplette Analyse mit einbezogen werden konnten. Ergebnisse: Bei 7,28% aller untersuchten Feten fanden sich Organfehlbildungen außerhalb des Zentralnervensystems. Unter diesen dominierten Harntraktfehlbildungen mit 63%. Als häufigste Diagnose wurde pränatal eine "Hydronephrose" angegeben. Dieser Begriff umschreibt jedoch in dem hier verwandten Sinne eine Harntransportstörung jeglicher Ursache. Echte Diagnosen obstruktiver Uropathien wurden lediglich zu 30% in den einzelnen Gruppen gestellt. Die pränatalen Verdachtsdiagnosen bestätigen sich zu zwischen 80 und 90% wenn: - eine isolierte Hydronephrose mit einem Nierenbeckendurchmesser von über 10 mm als Ureterabgangsstenose befundet wurde - die typische Konfiguration einer Multizystischen Nierendysplasie gefunden wurde - aus der Kombination von Oligohydramnion, Megazystis und bilateraler Harntransportstörung des männlichen Feten auf Urethralklappen geschlossen wurde. Lediglich bei der unilateralen multizystischen Nierendysplasie und der subpelvinen Obstruktion wird im pränatalen Befund bezüglich der definitiven Diagnose eine akzeptable Sensitivität und Spezifität erreicht. Alle anderen Diagnosen werden zu 70% postnatal gestellt. Der Einfluss der pränatalen Diagnostik auf das postnatale Management bezieht sich in erster Linie auf die Aufdeckung vorerst symptomloser Fehlbildungen. Eine pränatale Aussage über die zu erwartende Nierenfunktion ist bei einseitigen Fehlbildungen derzeit nicht möglich. Zusammenfassung: Obstruktive Uropathien sind häufige, zumeist benigne Fehlbildungen. Sie sind der pränatalen Diagnostik gut zugänglich. Konkrete Diagnosen mit Aussagen zur postnatalen therapeutischen Relevanz können jedoch nur gestellt werden, wenn sonografisch pathognomonische Konstellationen dies ermöglichen. In allen anderen Fällen muss die pränatal beschriebene Auffälligkeit Anlass zu postnataler sorgfältiger Diagnostik sein, um im präsymptomatischen Intervall die Entscheidung zu konservativer oder operativer Therapie stellen zu können. / Introduction: Among congenital dysplasias the anomalies of kidney and urogenital tract are among the most frequent encountered. Their rate in prenatally made diagnoses is about 50 %. Modern prenatal diagnostic facilities have changed the therapeutic access to these anomalies in the last decade. After a phase of overtreatment in the beginning, nowadays new insights in the natural course of these dysplasias and the results of long-term follow-up studies resulted in a more differentiated apporach. Questions and methods: In this retro- and prospective study we looked for the the influence of prenatal diagnostics on the postnatal course and management. The question was to examine the relationship between the prenatal ultrasound results, the suggested prenatal diagnosis and then the defintive postnatal disease. Of interest was the prognostic impact of typical prenatal sonographic imaging on the postnatal course of the baby. Because of its frequency we focused on anomalies of the kidney and urogenital tract. Patients: Between 1984 and 1996 21.616 pregnancies were examined by ultrasound in our Department of Prenatal Medicine. Among these, 1.574 anomalies of surgical relevance were described. 1.077 cases were available for follow-up including 990 cases of urogenital anomalies. Among these, the records of 693 cases were complete and these patients form the collective of this study. Results: When the CNS was excluded we found organic anomalies in 7,28 % of these cases. Among them 63% were attributed to the urogenital system. The most common prenatal diagnosis was "hydronephrosis". But this term was used only in a descriptive manner because proof of a real obstructive uropathy postnatally was made only in 30% of these cases. Concerning all anomalies of the urogenital tract, the prenatal diagnosis proved correct in the overwhelming majority of cases ( 90%) if these sonographic signs have been described: - diameter fo the renal pelvis of more than 10 mm in isolated hydronephrosis predicted ureteropelvic junction obstruction - typical formation of a multicystic dysplastic kidney - combination of oligohydramnion, megacystis and bilateral kidney anomalies in a male fetus predicted posterior urethral valve disease Sensitivity and specifity in regard to the definitive diagnosis were acceptable in multicystic dysplasia of the kidney and ureteropelvic junction obstruction. In all other cases, the correct diagnosis was made postnatally in 70 %. Therefore, the main value of prenatal sonography was to reveal otherwise symptomless dysplasias. Until now, a prenatal prediction of kidney function in the unilateral case is not possible. Conclusion: Obstructive uropathies are common an in most cases benign anomalies. They are easily detected by prenatal ultrasound. Therapeutical consequences, however, only arise in selected cases if typical sonographic signs can be seen. In the majority of cases, therefore, the main purpose of prenatal diagnostic ultrasound points out the necessity for postnatal diagnostic workup in order to detect and treat severe diseases before symptoms occur.
155

Determinação do genótipo RHD fetal no plasma materno: acurácia do teste semiautomatizado / Fetal RHD genotype determination in maternal plasma: Accuracy of a semi-automated test

Ziza, Karen Nogueira Chinoca 18 November 2015 (has links)
INTRODUÇÃO: A determinação do genótipo RHD fetal no plasma materno é um teste de diagnóstico pré-natal não invasivo oferecido a gestantes RhD negativo que apresentam potencial de sensibilização e/ou Doença Hemolítica Perinatal. Atualmente, este exame é realizado de rotina em diversos países, mas não no Brasil. A Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) oferece atendimento terciário a gestantes RhD negativo, com monitorização dos títulos de anticorpos irregulares, administração da imunoglobulina anti-D e/ou terapêutica fetal, quando necessários. OBJETIVO: Avaliar a acurácia do teste semiautomatizado para determinação do genótipo RHD fetal no plasma materno. METODOLOGIA: Foram coletadas prospectivamente amostras de sangue de 220 gestantes RhD negativo, com idade gestacional entre 8-28 semanas. O plasma foi obtido em no máximo 2 horas após a coleta, e uma alíquota de 1 mL foi submetida à extração de ácidos nucléicos no equipamento automatizado MagNA Pure Compact (Roche), empregando o kit Large Volume. O DNA extraído foi submetido a PCR em tempo real (Step One Plus - Applied Biosystems), usando o protocolo do grupo SAFE, que tem como alvos os éxons 5 e 7 do gene RHD. RESULTADOS: Ocorreu exclusão de 35 amostras devido a problemas pré-analíticos, aborto ou desconhecimento do fenótipo do recém-nascido. Entre as 185 amostras analisadas, 130 (70,2%) foram genotipadas como RHD+ e 55 (29,8%) RHD-. Os resultados obtidos foram comparados com a fenotipagem do cordão umbilical, e houve concordância completa (100%). Sete amostras exibiram amplificação exclusiva para o éxon 7. Essas amostras foram submetidas aos protocolos em PCR convencional, e PCR em tempo real específico para o pseudogene RHD. Ambos os ensaios apresentaram os mesmos resultados: cinco positivos e dois negativos. Nesses mesmos 7 casos, após extração da camada de leucócitos materna, os protocolos foram repetidos, e o resultado confirmou que cinco mães eram RHD. As duas amostras com resultado negativo foram submetidas ao protocolo Multiplex, envolvendo os éxons 3-9 do gene RHD, com resultados negativos, confirmando que as mães são verdadeiramente RHD- portanto o sinal do éxon 7 é provindo dos fetos que são D variantes. CONCLUSÃO: O método para a determinação do RHD fetal no plasma materno descrito demonstrou ser rápido, de fácil execução, alta precisão e reprodutível, além de indicar possíveis variantes RHD em nossa população / BACKGROUND: Fetal RHD genotype determination in maternal plasma is a noninvasive prenatal diagnostic test performed in RhD negative pregnant women at risk of alloimmunization and/or Hemolytic Disease of Fetus and Newborn. Currently, this test is routinely performed in many countries but not in Brazil. The Department of Obstetrics at Hospital das Clínicas, São Paulo University Medical School provides tertiary antenatal care for RhD negative pregnant women including anti-D immunoglobulin administration, antibody levels monitoring and intrauterine treatment if necessary. AIMS: To validate the accuracy of a semi-automated test for fetal RHD genotype determination in maternal plasma. METHODS: Two-hundred and twenty blood samples were prospectively collected between 8 and 28 weeks of gestational age. Plasma processing was performed within 2 hours after blood collection, and nucleic acids were extracted from 1mL aliquots with an automated extraction platform (MagNA Pure Compact Roche) and the Large Volume kit. RHD gene exons 5 and 7 were amplified with real-time PCR (Step One Plus - Applied Biosystems) using the SAFE group protocol. RESULTS: Thirty-five samples were excluded due to pre-analytical problems, miscarriage and missing follow-up. In the remaining 185 samples, 130 (70.2%) were genotyped as RhD+ and 55 (29.8%) RhD-. Comparison with umbilical cord blood group phenotype showed 100% concordance. Seven samples showed amplification for exon 7 only. These were further investigated with conventional and real-time PCR with an specific protocol for RHD? pseudogene: 5 were positive and 2, negative. In these 7 cases, maternal buffy-coat DNA analysis also confirmed that 5 women were RHD?. In the remaining 2 cases, a multiplex protocol directed at RHD gene exons 3-9 confirmed that both mothers were truly RhD negative so exon 7 signal comes from the fetuses, further found to harbor D variants. CONCLUSION: The present study demonstrates that fetal RHD determination in maternal plasma is a fast, easy-to-perform and reproducible technique with high accuracy in our population. Moreover, it helps in the identification of possible RHD variants in our population
156

Desenvolvimento de um teste para a trissomia do cromossomo 21 através da análise de ácidos nucleicos fetais no plasma materno por sequenciamento de última geração / Development of a trisomy 21 test by analysis of fetal nucleic acids in maternal plasma by next-generation sequencing

Romão, Renata Moscolini 22 June 2016 (has links)
O objetivo do presente trabalho foi o desenvolvimento de um teste não invasivo para a trissomia do cromossomo 21 através da análise de ácidos nucleicos fetais livres no plasma materno por sequenciamento de última geração realizado no sequenciador automático Ion Torrent. A metodologia proposta para o teste é a análise de SNPs com alta taxa de heterozigosidade na população brasileira localizados em dois genes presentes no cromossomo 21 (PLAC4 e C21orf105), e a detecção da cópia extra do cromossomo 21 é feita pela razão dos alelos desses SNPs, sendo que a razão de 1:1 indica que o feto é normal, e a razão de 2:1 indica que o feto tem uma cópia extra do cromossomo 21. Para a validação da metodologia foram utilizadas 50 amostras de DNA livre extraídas de líquido amniótico, previamente caracterizadas por análise citogenética consideradas como o padrão ouro pois contém apenas material genético fetal abundante. A metodologia foi validada com sucesso nessas amostras, sendo que as 24 amostras de fetos com trissomia foram claramente distinguidas das 26 amostras de fetos normais. A metodologia validada foi aplicada a 44 amostras de DNA livre extraídas de plasma de gestantes (21 amostras de fetos com trissomia do 21 e 23 de fetos normais), porém não foi possível fazer a distinção entre fetos normais e fetos com trissomia do 21, possivelmente devido à variações na fração fetal do DNA livre em relação à fração materna. Como nosso objetivo principal não foi alcançado, Propomos aqui que o teste realizado em líquido amniótico seja utilizado como uma alternativa mais simples, rápida e barata ao cariótipo convencional atualmente utilizado para fazer o diagnóstico da trissomia do cromossomo 21 em amostras coletadas por procedimentos invasivos, enquanto as deficiências do teste não-invasivo pelo plasma materno são aprimoradas / The purpose of this study was to develop a test for trisomy 21 by analyzing cell-free fetal nucleic acids in maternal plasma by next-generation sequencing performed on automated sequencer Ion Torrent. The proposed methodology for the test is based on analysis of SNPs with high heterozygosity rates in Brazilian population, located in two genes present on chromosome 21 (PLAC4 and C21orf105), and the detection of the extra copy of chromosome 21 is made by the allelic-ratio of these SNPs, where 1:1 ratio indicates a normal fetus, and the 2:1 ratio indicates that the fetus has an extra copy of chromosome 21. In order to validate the methodology 50 cell-free DNAs extracted from amniotic fluid were used representing a gold standard since it contains abundant genetic material exclusively from the fetus. The methodology has been successfully validated in these samples, all the 24 samples from fetuses with trisomy 21 were clearly distinguished from 26 samples of normal fetuses. The validated method was applied to 44 cell-free DNA samples extracted from plasma of pregnant women (21 samples from fetuses with trisomy 21 and 23 from normal fetuses), but unfortunately it was not possible to distinguish between normal and trisomy 21 fetuses, possibly due to variations on the fetal fraction of the cell-free DNA in relation to maternal fraction. As our main goal was not achieved, we propose here that the test performed on amniotic fluid sample could be used as a simpler, faster and cheaper alternative test to traditional karyotype, which is used nowadays to make the diagnosis of trisomy 21 in samples collected by invasive procedures. In parallel, minor improvements in the described method may enable its clinical use
157

Determinação do genótipo RHD fetal no plasma materno: acurácia do teste semiautomatizado / Fetal RHD genotype determination in maternal plasma: Accuracy of a semi-automated test

Karen Nogueira Chinoca Ziza 18 November 2015 (has links)
INTRODUÇÃO: A determinação do genótipo RHD fetal no plasma materno é um teste de diagnóstico pré-natal não invasivo oferecido a gestantes RhD negativo que apresentam potencial de sensibilização e/ou Doença Hemolítica Perinatal. Atualmente, este exame é realizado de rotina em diversos países, mas não no Brasil. A Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) oferece atendimento terciário a gestantes RhD negativo, com monitorização dos títulos de anticorpos irregulares, administração da imunoglobulina anti-D e/ou terapêutica fetal, quando necessários. OBJETIVO: Avaliar a acurácia do teste semiautomatizado para determinação do genótipo RHD fetal no plasma materno. METODOLOGIA: Foram coletadas prospectivamente amostras de sangue de 220 gestantes RhD negativo, com idade gestacional entre 8-28 semanas. O plasma foi obtido em no máximo 2 horas após a coleta, e uma alíquota de 1 mL foi submetida à extração de ácidos nucléicos no equipamento automatizado MagNA Pure Compact (Roche), empregando o kit Large Volume. O DNA extraído foi submetido a PCR em tempo real (Step One Plus - Applied Biosystems), usando o protocolo do grupo SAFE, que tem como alvos os éxons 5 e 7 do gene RHD. RESULTADOS: Ocorreu exclusão de 35 amostras devido a problemas pré-analíticos, aborto ou desconhecimento do fenótipo do recém-nascido. Entre as 185 amostras analisadas, 130 (70,2%) foram genotipadas como RHD+ e 55 (29,8%) RHD-. Os resultados obtidos foram comparados com a fenotipagem do cordão umbilical, e houve concordância completa (100%). Sete amostras exibiram amplificação exclusiva para o éxon 7. Essas amostras foram submetidas aos protocolos em PCR convencional, e PCR em tempo real específico para o pseudogene RHD. Ambos os ensaios apresentaram os mesmos resultados: cinco positivos e dois negativos. Nesses mesmos 7 casos, após extração da camada de leucócitos materna, os protocolos foram repetidos, e o resultado confirmou que cinco mães eram RHD. As duas amostras com resultado negativo foram submetidas ao protocolo Multiplex, envolvendo os éxons 3-9 do gene RHD, com resultados negativos, confirmando que as mães são verdadeiramente RHD- portanto o sinal do éxon 7 é provindo dos fetos que são D variantes. CONCLUSÃO: O método para a determinação do RHD fetal no plasma materno descrito demonstrou ser rápido, de fácil execução, alta precisão e reprodutível, além de indicar possíveis variantes RHD em nossa população / BACKGROUND: Fetal RHD genotype determination in maternal plasma is a noninvasive prenatal diagnostic test performed in RhD negative pregnant women at risk of alloimmunization and/or Hemolytic Disease of Fetus and Newborn. Currently, this test is routinely performed in many countries but not in Brazil. The Department of Obstetrics at Hospital das Clínicas, São Paulo University Medical School provides tertiary antenatal care for RhD negative pregnant women including anti-D immunoglobulin administration, antibody levels monitoring and intrauterine treatment if necessary. AIMS: To validate the accuracy of a semi-automated test for fetal RHD genotype determination in maternal plasma. METHODS: Two-hundred and twenty blood samples were prospectively collected between 8 and 28 weeks of gestational age. Plasma processing was performed within 2 hours after blood collection, and nucleic acids were extracted from 1mL aliquots with an automated extraction platform (MagNA Pure Compact Roche) and the Large Volume kit. RHD gene exons 5 and 7 were amplified with real-time PCR (Step One Plus - Applied Biosystems) using the SAFE group protocol. RESULTS: Thirty-five samples were excluded due to pre-analytical problems, miscarriage and missing follow-up. In the remaining 185 samples, 130 (70.2%) were genotyped as RhD+ and 55 (29.8%) RhD-. Comparison with umbilical cord blood group phenotype showed 100% concordance. Seven samples showed amplification for exon 7 only. These were further investigated with conventional and real-time PCR with an specific protocol for RHD? pseudogene: 5 were positive and 2, negative. In these 7 cases, maternal buffy-coat DNA analysis also confirmed that 5 women were RHD?. In the remaining 2 cases, a multiplex protocol directed at RHD gene exons 3-9 confirmed that both mothers were truly RhD negative so exon 7 signal comes from the fetuses, further found to harbor D variants. CONCLUSION: The present study demonstrates that fetal RHD determination in maternal plasma is a fast, easy-to-perform and reproducible technique with high accuracy in our population. Moreover, it helps in the identification of possible RHD variants in our population
158

Desenvolvimento de um teste para a trissomia do cromossomo 21 através da análise de ácidos nucleicos fetais no plasma materno por sequenciamento de última geração / Development of a trisomy 21 test by analysis of fetal nucleic acids in maternal plasma by next-generation sequencing

Renata Moscolini Romão 22 June 2016 (has links)
O objetivo do presente trabalho foi o desenvolvimento de um teste não invasivo para a trissomia do cromossomo 21 através da análise de ácidos nucleicos fetais livres no plasma materno por sequenciamento de última geração realizado no sequenciador automático Ion Torrent. A metodologia proposta para o teste é a análise de SNPs com alta taxa de heterozigosidade na população brasileira localizados em dois genes presentes no cromossomo 21 (PLAC4 e C21orf105), e a detecção da cópia extra do cromossomo 21 é feita pela razão dos alelos desses SNPs, sendo que a razão de 1:1 indica que o feto é normal, e a razão de 2:1 indica que o feto tem uma cópia extra do cromossomo 21. Para a validação da metodologia foram utilizadas 50 amostras de DNA livre extraídas de líquido amniótico, previamente caracterizadas por análise citogenética consideradas como o padrão ouro pois contém apenas material genético fetal abundante. A metodologia foi validada com sucesso nessas amostras, sendo que as 24 amostras de fetos com trissomia foram claramente distinguidas das 26 amostras de fetos normais. A metodologia validada foi aplicada a 44 amostras de DNA livre extraídas de plasma de gestantes (21 amostras de fetos com trissomia do 21 e 23 de fetos normais), porém não foi possível fazer a distinção entre fetos normais e fetos com trissomia do 21, possivelmente devido à variações na fração fetal do DNA livre em relação à fração materna. Como nosso objetivo principal não foi alcançado, Propomos aqui que o teste realizado em líquido amniótico seja utilizado como uma alternativa mais simples, rápida e barata ao cariótipo convencional atualmente utilizado para fazer o diagnóstico da trissomia do cromossomo 21 em amostras coletadas por procedimentos invasivos, enquanto as deficiências do teste não-invasivo pelo plasma materno são aprimoradas / The purpose of this study was to develop a test for trisomy 21 by analyzing cell-free fetal nucleic acids in maternal plasma by next-generation sequencing performed on automated sequencer Ion Torrent. The proposed methodology for the test is based on analysis of SNPs with high heterozygosity rates in Brazilian population, located in two genes present on chromosome 21 (PLAC4 and C21orf105), and the detection of the extra copy of chromosome 21 is made by the allelic-ratio of these SNPs, where 1:1 ratio indicates a normal fetus, and the 2:1 ratio indicates that the fetus has an extra copy of chromosome 21. In order to validate the methodology 50 cell-free DNAs extracted from amniotic fluid were used representing a gold standard since it contains abundant genetic material exclusively from the fetus. The methodology has been successfully validated in these samples, all the 24 samples from fetuses with trisomy 21 were clearly distinguished from 26 samples of normal fetuses. The validated method was applied to 44 cell-free DNA samples extracted from plasma of pregnant women (21 samples from fetuses with trisomy 21 and 23 from normal fetuses), but unfortunately it was not possible to distinguish between normal and trisomy 21 fetuses, possibly due to variations on the fetal fraction of the cell-free DNA in relation to maternal fraction. As our main goal was not achieved, we propose here that the test performed on amniotic fluid sample could be used as a simpler, faster and cheaper alternative test to traditional karyotype, which is used nowadays to make the diagnosis of trisomy 21 in samples collected by invasive procedures. In parallel, minor improvements in the described method may enable its clinical use
159

Predição do resultado perinatal em gestações trigemelares / Prediction of perinatal outcome in triplet pregnancies

Carolina Bastos Maia 11 June 2014 (has links)
O presente estudo tem como objetivo descrever a mortalidade perinatal em gestações trigemelares, e analisar os fatores preditores dos seguintes desfechos: número de crianças vivas no momento da alta hospitalar, nenhuma criança viva no momento da alta hospitalar (desfavorável) e pelo menos uma criança viva no momento da alta hospitalar (favorável). Realizado de forma retrospectiva, envolveu pacientes com gestações trigemelares que apresentavam três fetos vivos na primeira ultrassonografia realizada após 11 semanas, no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP), no período de 1998 a 2012. Foram incluídas 67 pacientes das quais 77,6% referiam concepção espontânea. Quanto à corionicidade, 49,2% eram tricoriônicas e 50,8% eram não tricoriônicas; 16,4% apresentavam antecedente clínico prévio à gestação e 49,2% eram nulíparas. Em relação às intercorrências, a incidência de complicações obstétricas e/ou clínicas na gestação foi de 52,2%, e de intercorrências fetais, 25,2%, dentre as quais: 13,4% mal formações, 7,5% sindrome da transfusão feto fetal (STFF), 5,9% óbito fetal (OF), 4,5% insuficiência placentária, 4,4% fetos unidos, 1,5% feto acárdico. A idade gestacional média do parto foi de 31,9 ± 3,1 semanas, dos quais 83,5% foram cesáreas. O peso médio dos recém-nascidos vivos de 1.683 ± 508 g. Em relação à discordância de peso ao nascer: 57% apresentaram até 20%, 23,2% entre 20 e 30% e 19,6% acima de 30%. A taxa de óbitos fetais foi de 31,7%o nascimentos (IC95%: 11,7 - 67,8) e a mortalidade perinatal 249%o nascimentos (IC95%: 189 - 317). O tempo médio de internação dos recém-nascidos, que foram de alta vivos, foi de 29,3 ± 24,7 dias. A predição dos desfechos foi investigada por meio de regressão logística \"stepwise\", e incluiu as seguintes variáveis: idade materna, paridade (nulípara ou um ou mais partos anteriores), antecedente clínico, idade gestacional do primeiro ultrassonografia no HCFMUSP, corionicidade (gestações tricoriônicas e gestações não tricoriônicas), presença de complicação obstétrica ou clínica durante a gestação, intercorrência fetal e idade gestacional do parto. O nível de significância estatística utilizado foi de 0,005. Foram fatores significativos para predição do número de crianças vivas no momento da alta hospitalar: presença de intercorrência fetal (OR 0,1, IC95%: 0,03 - 0,36; p < 0,001) e idade gestacional do parto (OR 1,55, IC95%: 1,31-1,85; p < 0,001). Para a predição dos desfechos favoráveis e desfavoráveis a idade gestacional do parto apresentou significância estatística (OR 1,84, IC95%: 1.26 - 2.7; p=0,002 e OR 0.54, IC 95%: 0.37-0.79; p=0.002, respectivamente) / The present study, involving triplet pregnancies, describes perinatal mortality and investigates predictors of the following outcomes: number of children alive, no child alive (unfavorable outcome) and at least one child alive (favorable outcome) at hospital discharge. It is a retrospective study involving triplet pregnancies with live fetuses at the first ultrasound scan, performed after 11 weeks of gestation, at the Department of Obstetrics and Gynecology, São Paulo University Medical School Hospital, between 1998 and 2012. Final sample included 67 women, 77.6% reported spontaneous conception. Regarding the chorionicity, 49.2% were trichorionic; 16.4% had a medical complication prior to pregnancy, and 49.2% were nulliparous. The incidence of obstetric and/or clinical complications during pregnancy was 52.2%, and fetal complications occurred in 25.2%, (13.4% of major fetal abnormalities, 7.5% twin-to-twin transfusion syndrome, 5.9% stillbirth, 4.5% placental insufficiency, 4.4% conjoined twins and 1.5% acardic twin). The average gestational age at delivery was 31.9 ± 3.1 weeks, and 83.5% were cesarean. The average birthweight was 1683 ± 508 g and birth weight discordance up to 20% occurred in 57% of the cases; 23,2% had 20 to 30% discordance and 19.6%, was greater than 30%. The rate of stillbirth was 31.7%o births (95%CI: 11.7 - 67.8) and the perinatal mortality was 249%o births (95%CI: 189 - 317). The average hospital stay was 29.3 ± 24.7 days amongst children that were discharged alive. Stepwise logistic regression analysis was used to investigate prediction according to: maternal age, parity (nuliparous/multiparous), prior clinical history, gestational age at the first ultrasound scan at HCFMUSP, pregnancy chorionicity (trichorionic/non trichorionic), occurrence of clinical and/or obstetric complications during pregnancy, occurrence of fetal complications and gestational age at delivery. Significance level was set at 0.05. The number of children alive at hospital discharge was correlated with the occurrence of fetal complications (OR 0,1, 95%IC: 0,03 - 0,36; p < 0,001) and gestational age at delivery (OR 1,55, IC95%: 1,31-1,85; p < 0,001). Whereas favorable and unfavorable outcome were associated with gestational age at delivery (OR 1.84, 95%CI: 1.26 - 2.7-; p=0,002 and OR 0.54, 95%CI: 0.37-0.79; p=0.002, respectively)
160

Estudi de les anomalies cromosòmiques detectades prenatalment i postnatalment per mètodes citogenètics i anàlisi de la contribució dels diferents mètodes de cribratge en la detecció de les anomalies prenatals. Hospital Universitari Dr. Josep Trueta, període 1999-2009

Alsius Suñer, Mercè 28 September 2012 (has links)
Chromosome abnormalities are one of the most important causes of congenital disorders. The main goal of this research is to give a broad view of the use and evolution of prenatal and postnatal cytogenetic diagnosis in Girona province between 1999 and 2009. It also aims at linking prenatal cytogenetic diagnosis with the existing screening methods. The main conclusions are the following: - A rise in the use of cytogenetic diagnosis has been detected. This has been caused by a growing preventive medicine trend. - Case studies match the literature consulted when the study population is similar in accordance with national health policies. - The overall sensitivity of obstetric ultrasound scan was 60,8%, and this result matches, and in many cases exceeds, those found in the literature consulted. - The moving from second-trimester to first-trimester aneuploidy prenatal screening has meant a significant increase in aneuploidy detections. - Prenatal cytogenetic diagnosis appears as an interdisciplinary field in which the extent of prenatal screening tests, like obstetric ultrasound scans and aneuploidy screening, is crucial. / Les anomalies cromosòmiques són una de les causes més importants dels defectes congènits. L’objectiu d’aquest treball és donar una visió global de l’ús i l’evolució del diagnòstic citogenètic prenatal i postnatal a les comarques de Girona en el període 1999-2009 i relacionar el diagnòstic citogenètic prenatal amb els diferents mètodes de cribratge. Les conclusions principals són: - Es constata un augment de l’ús del diagnòstic citogenètic com a resultat d’una tendència creixent en medicina preventiva. - La casuística coincideix amb la bibliografia consultada quan la població d’estudi és semblant, atenent a la política sanitària del país. - La sensibilitat global de l’ecografia obstètrica va ser del 60,8%, i és un resultat concordant i en molts casos millor en comparació amb la literatura consultada. - La substitució del cribratge del segon trimestre pel cribratge del primer trimestre ha suposat un increment important en la detecció d’aneuploïdies. - El diagnòstic citogenètic prenatal es mostra com a una àrea interdisciplinària en què la contribució de les proves de cribratge prenatal com l’ecografia obstètrica i el cribratge d’aneuploïdies són importants.

Page generated in 0.0794 seconds