• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 3
  • Tagged with
  • 44
  • 40
  • 32
  • 22
  • 14
  • 14
  • 11
  • 9
  • 9
  • 9
  • 7
  • 7
  • 7
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeitos da radia??o UV sobre as termina??es nervosas da pele humana

Rodriguez, Adriane Lucia 31 March 2008 (has links)
Made available in DSpace on 2015-04-14T14:50:51Z (GMT). No. of bitstreams: 1 401340.pdf: 549118 bytes, checksum: 0b891fb7ecb8b42c15bbd983f6da4c5e (MD5) Previous issue date: 2008-03-31 / Introdu??o: Atualmente, devido ? polui??o e emiss?o de gases t?xicos, h? uma degrada??o gradual da camada de oz?nio que filtra uma grande parcela das emiss?es UV. A radia??o UV altera significativamente as estruturas da pele, incluindo as termina??es nervosas. Em decorr?ncia do crescente aumento de doen?as de pele relacionadas ? exposi??o UV, faz-se necess?ria a avalia??o da efetividade de novos princ?pios ativos com finalidade de prote??o contra as radia??es. Estudos anteriores n?o foram capazes de quantificar o dano induzido pela radia??o UV nas termina??es nervosas. Objetivos: identificar as termina??es nervosas na pele humana, quantificar os efeitos das radia??es UV sobre as termina??es nervosas e verificar o efeito de princ?pios ativos neuroprotetores ? exposi??o UV. Materiais e M?todos: bi?psias de pele, de 35 adultos saud?veis, sob cirurgia pl?stica, foram obtidas e imediatamente tratadas com tr?s emuls?es: Creme1, Creme2 (placebo) e FPS 15. As amostras tratadas com as emuls?es ou controle (sem creme) foram submetidos ? exposi??o UVA e UVB por 60 min. Sec??es de 15 m foram produzidas no criostato a partir de tecidos congelados e as estruturas nervosas foram identificadas por imunofluoresc?ncia utilizando um anticorpo monoclonal anti-CD56 (NCAM) humano. O dano nas termina??es foi identificado a partir da sele??o autom?tica de pixels (verde FITC) das imagens capturadas. Resultados: foram identificadas v?rias estruturas nervosas na pele, incluindo termina??es livres, inerva??es do fol?culo piloso e gl?ndulas seb?ceas. As radia??es UVA e UVB reduziram, significativamente (40-60%), a densidade das termina??es nervosas na pele nas amostras controle, tratadas com placebo ou FPS 15 (p<0.001). N?o foram observadas diferen?as morfol?gicas das termina??es nervosas expostas a radia??o UV. As amostras tratadas com o Creme1 bloquearam completamente os efeitos da radia??o UV sobre as termina??es nervosas (p > 0.05). Discuss?o: A quantifica??o dos danos celulares induzidos pela radia??o UV possibilita a identifica??o de compostos ativos com propriedades neuroprotetoras. Os mecanismos de dano celular bem como as atividades neuroprotetoras merecem ser identificadas nos pr?ximos estudos.
12

Estudo da influ?ncia da radia??o ionizante na tra??o diametral de cimentos de ion?mero de vidro

Carvalho, L?gia Maria Nogarett Pibernat de 22 January 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:21Z (GMT). No. of bitstreams: 1 447499.pdf: 1220265 bytes, checksum: e49cb6ce6026a77ac053d20f7598d292 (MD5) Previous issue date: 2013-01-22 / The aim of this study was evaluate the influence of ionizing radiation under three glass ionomer (conventional, resin modified and silver added) on the diametral tensile strength. The null hypothesis tested the action of ionizing radiation under glass ionomer cements submitted to tensile strength. To diametral tensile strength, samples were made with conventional (n=20), resin modified (n=20), silver added glass ionomer cements (n=20) into a cylindrical bipartite mould of PTFE (polytetrafluoroethylene) with 6 mm diameter X 3 mm high according to manufacturer s instructions. All samples were stored in plastic tubes protected from light for 24 h at 37? C in a culture stove. After that, each group was divided in a control or submitted to ionizing radiation at Centro de Oncologia do Hospital M?e de Deus, with usual dose for head and neck cancer fractioned in 35 daily applications of 2 Gy (200cGy) for each Day, resulting at 70 Gy (7000cGy) by a linear accelerator. In order to avoid sub dosage at the material surface due to Build-up effect, a Bolus was used with 2mm simulating soft tissues. The diametral tensile strength test was performed in a universal testing machine EMIC DL 2000 (Emic, S?o Jos? dos Pinhais, Brazil), with 1 mm/min of cross-head speed. Data were submitted to analysis of variance and multiple comparison test of Tukey (&#945;=0.05). Significant differences were recorded (p<0.001) between the glass ionomer tested (conventional, resin modified and silver added) for diametral tensile strength. Comparing groups with the same classification, submitted or not to radiation, there was no significant difference. Riva Light Cure control showed an average (MPa) of 31.83 in comparison to 24.82 of irradiated group. Riva Silver control showed an average (MPa) of 12.06 in comparison to 17.29 for the irradiated group. Riva Self Cure control showed an average (MPa) of 14.05 in comparison to 26.04 irradiated group. Comparing all groups of different classification submitted to ionizing radiation, there were significant difference between them (p<0.001). Riva Silver control showed the lowest average (MPa) (12.03) in comparison to Riva Light control (31.83). The radiotherapy applied as protocol to head and neck cancer therapy do not act negatively in the diametral tensile strength of the three glass ionomer tested. / Este estudo teve como objetivo avaliar a influ?ncia da radia??o ionizante sobre tr?s cimentos de ion?mero de vidro, convencional, modificado por resina e modificado por liga de prata, quanto ? tra??o diametral. A hip?tese nula deste estudo testou a a??o da radia??o ionizante sobre os cimentos de ion?mero de vidro submetidos a tra??o diametral. Para o teste de tra??o diametral foram confeccionadas amostras para cada grupo de ion?mero de vidro: Convencional (n=20), modificado por resina (n=20), modificado por liga de prata (n=20), em uma matriz bipartida de PTFE (politetrafluoetileno) cil?ndrica de 6 mm de di?metro X 3 mm de altura utilizando t?cnica indicada pelo fabricante. Todas as amostras, ap?s a confec??o, foram armazenadas em recipientes pl?sticos protegidos da luz pelo per?odo de 24h ? 37? C em uma estufa para culturas. Ap?s cada grupo foi dividido em um grupo controle ou um grupo submetido a radia??o ionizante no Centro de Oncologia do Hospital M?e de Deus, com dose usual para tratamento de neoplasias de cabe?a e pesco?o fracionada em 35 aplica??es de 2 Gy (200cGy) ao dia, durante 35 dias, totalizando a dose de 70 Gy (7000cGy), atrav?s de um acelerador linear na tentava de simular a dose e o tempo de uma radioterapia de cabe?a e pesco?o. Para evitar sub dosagem na superf?cie do material devido ao efeito Build-up (ac?mulo), foi utilizado B?lus de 2mm simulando tecidos moles circundantes. O ensaio de resist?ncia ? tra??o diametral foi realizado em uma m?quina de ensaio Universal EMIC DL 2000, com velocidade de carregamento de 1mm/min, at? a fratura do corpo-de-prova. Os dados foram avaliados pela an?lise de vari?ncia e teste de compara??es m?ltiplas de Tukey (&#945;=0,05). Foram observadas diferen?as significativas (p<0,001) entre os tr?s grupos de cimento de ion?mero de vidro avaliados (convencional, modificado por resina e modificado por liga de prata) no ensaio de tra??o diametral. Ao comparar os grupos de mesma classifica??o, submetidos ou n?o ? radia??o, n?o houve diferen?a significante, o grupo Riva Light Cure controle obtiveram a m?dia (MPa) de 31,83 e o grupo irradiado 24,82. O grupo Riva Silver controle obteve m?dia (MPa) de 12,06 e no grupo irradiado 17,29. O grupo Riva Self Cure controle apresentaram uma m?dia (MPa) de 14,05 enquanto o grupo irradiado obteve 26,04. Ao comparar todos os grupos de diferentes classifica??es que foram submetidos ? radia??o, houve diferen?a estatisticamente significante entre eles (p<0,001). O grupo Riva Silver controle apresentou menor valor (MPa) (12,03) quando comparado ao grupo Riva Light controle (31,83). A radioterapia aplicada como protocolo no tratamento de pacientes com c?ncer de cabe?a e pesco?o n?o influi negativamente na tra??o diametral dos tr?s diferentes cimentos de ion?mero de vidro pesquisados.
13

Conserva??o p?s-colheita de frutos do maracujazeiro-doce irradiados. / Conservation post-harvest fruit of passion sweetfruit irradiated.

Floriano, Cristiano Magela 20 February 2004 (has links)
Made available in DSpace on 2016-04-28T14:58:37Z (GMT). No. of bitstreams: 1 2004 - Cristiane Magela Floriano.pdf: 765031 bytes, checksum: a9dc1e79d63d53940ee5a888798748c5 (MD5) Previous issue date: 2004-02-20 / Brazil has been highlighted as a major producer of fruits, especially tropical and subtropical. The passion fruit belongs to the family PASSIFLORACEAE and order PASSIFLORALES. The gender PASSIFLORAS is composed of at least 400 species, all originated from Tropical America and belongs to the sub-gender GRANADILLA, Quadrangles serie. The PASSIFLORA ALATA CURTIS is a native species and fairly widespread occurrence in Brazil where it is also commonly known by passion sweetfruit among other names. In Brazil, the species is found from the State Bahia all the way to the State of Rio Grande do Sul, showing good adaptation to the conditions EDAFOCLIM?TICAS. Considering the market potential, special attention should be given in post-harvest of passion sweet-fruit. This task aims to evaluate the behavior post-harvest of the passion sweet-fruit (PASSIFLORA ALATA CURTIS) submitted to the application of different doses of radiation gamma aimed at increasing the conservation period, with maintenance of quality and health. This work was developed in post-harvest in the laboratory of the Department of FITOTECCNIA - Institute of Agriculture UFRRJ with fruits collected at the Site of Passion sweet-fruit, in the municipality of Paty do Alferes. After being selected, they were transported to the Office of Research and Development to be irradiated. The fruits received the following treatments: Irradiation with source of C?sio 137 (137Cs) at doses of 0.1, 0.2, 0.5 and 1.0 kGy. After treatment, all fruits were stored at a temperature of 12 C and 90% UR. Assessments were made every 4 days through determinations of appearance, loss of fresh weight, firmness equatorial and apical, soluble solids, pH, total titratable acidity, ascorbic acid and longevity of the fruits. All fruits, regardless of the dose of gamma radiation that were submitted showed changes in appearance during the period of storage and tended to loss both firmness as well firmness apical and equatorial. There was a small variation in levels of soluble solids, and the process of irradiation led the fruits of sweet passion fruit to no traditional behavior, not only showing a trend of accumulation or reduction of soluble solids total. It follows that the lower doses favored to increase the conservation period with maintaining the health and quality of the fruits of fresh passion fruit during the 28 days of storage fruits. / O Brasil tem se destacado como grande produtor de frutas, especialmente as tropicais e subtropicais. O maracujazeiro pertence ? fam?lia Passifloraceae e ? ordem Passiflorales. O g?nero Passifloras ? composto de pelo menos 400 esp?cies, todas elas originadas da Am?rica Tropical e pertence ao sub-g?nero Granadilla, s?rie Quadrangulares. A Passiflora alata Curtis ? uma esp?cie ind?gena e de ocorr?ncia bastante generalizada no Brasil onde ? tamb?m conhecida vulgarmente por maracuj?-doce entre outros nomes. No Brasil, a esp?cie ? encontrada da Bahia at? o Rio Grande do Sul, apresentando boa adapta??o ?s condi??es edafoclim?ticas. Considerando o potencial de mercado, uma especial aten??o deve ser dada na p?s-colheita de maracuj?-doce. Este trabalho tem como objetivo avaliar o comportamento p?s-colheita de frutos do maracujazeiro-doce (Passiflora alata Curtis) submetidos ? aplica??o de diferentes doses de radia??o gama visando aumento do per?odo de conserva??o com manuten??o de qualidade e sanidade. O presente trabalho foi desenvolvido no Laborat?rio de P?s-Colheita do Departamento de Fitotecnia Instituto de Agronomia da UFRRJ com frutos obtidos no S?tio do Maracuj?-doce, no munic?pio de Paty do Alferes. Ap?s serem selecionados, os mesmos foram transportados at? o Instituto de Pesquisa e Desenvolvimento para serem irradiados. Os frutos receberam os seguintes tratamentos: Irradia??o com fonte de C?sio 137 (137Cs) nas doses de 0,1; 0,2; 0,5 e 1,0 kGy. Ap?s o tratamento, todos os frutos foram armazenados em temperatura de 12?C e 90% de UR. Foram feitas avalia??es de 4 em 4 dias atrav?s de determina??es de apar?ncia, perda de massa fresca, firmeza apical e equatorial, s?lidos sol?veis totais, pH, acidez total titul?vel, ?cido asc?rbico e longevidade dos frutos. Todos os frutos, independente da dose de radia??o gama a que foram submetidos apresentaram altera??es na apar?ncia no decorrer do per?odo de armazenamento e tiveram tend?ncia a perda de firmeza tanto firmeza apical quanto firmeza equatorial. Houve uma pequena varia??o no teor de s?lidos sol?veis totais, sendo que o processo de irradia??o levou os frutos de maracuj?-doce a um comportamento n?o tradicional, n?o apresentando a uma tend?ncia ?nica de ac?mulo ou de redu??o de s?lidos sol?veis totais. Conclui-se que as doses mais baixas favoreceram ao aumento do per?odo de conserva??o com manuten??o da qualidade e sanidade dos frutos do maracujazeiro doce durante o per?odo de 28 dias de armazenamento dos frutos.
14

TC com muito baixa dose de radia??o, inferior a radiografia panor?mica: protocolo CTdBem para tomografia Multislice dental em pediatria

Haygert, Carlos Jesus Pereira 12 July 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2017-03-10T17:30:42Z No. of bitstreams: 1 TES_CARLOS_JESUS_PEREIRA_HAYGERT_PARCIAL.pdf: 1035016 bytes, checksum: 2e1b1323cdbd59f0bc70829382bd1563 (MD5) / Made available in DSpace on 2017-03-10T17:30:42Z (GMT). No. of bitstreams: 1 TES_CARLOS_JESUS_PEREIRA_HAYGERT_PARCIAL.pdf: 1035016 bytes, checksum: 2e1b1323cdbd59f0bc70829382bd1563 (MD5) Previous issue date: 2016-07-12 / Objective: To compare the total radiation doses obtained in an optimized protocol tomography (MSCT) for hospital use (CTdBem), with the doses obtained in panoramic radiography for dental use, both in pediatric patients and to compare the actual radiation doses to lens, thyroid, salivary glands and gonads obtained from MSCT x panoramic radiograph. Methods: radiation dose data obtained were used in examinations of pediatric patients, and children under 18 years of age treated at the University Hospital of Santa Maria (HUSM), who needed dental evaluation by diagnostic imaging methods. The value of the estimated effective dose of radiation was obtained by computational calculations using the data CTDI (Computed Tomography Dose Index) and DLP (Dose Lenght Product) of MSCT and DAP values (Dose Area Product) for panoramic radiography equipment. The organs were: crystalline, thyroid, salivary glands and gonads, and compared the effective doses of radiation obtained for the different equipment. The radiographic examinations were performed using the pan in equipment X-ray Instrumentarium OP200, 57-85kV, 2-16mAs and acquisition time of approximately 11 seconds. For MSCT was used Toshiba Aquilion64 using 120kV, 10mAs but and acquisition time of approximately 6 seconds. Results: Comparison of DLP CTdBem protocol with panoramic radiograph showed dose values 28,48mSv and 36,45mSv respectively. Comparing the effective doses were found dose values for salivary gland 0,28mSv and 0,36mSv to gonads 2,28mSv and 2,92mSv for thyroid 0,28mSv and 0,36mSv and lens 3, 42mSv and 4,37mSv. Conclusion and Clinical Relevance: The authors conclude that the total doses and also the effective doses of radiation to lens, thyroid, salivary glands and gonads obtained in an optimized protocol of multislice computed tomography for hospital use (CTdBem) doses were lower based on panoramic radiographs. / Objetivo: Comparar as doses totais de radia??o obtidas em um protocolo otimizado de tomografia computadorizada multislice (TCMS) para uso hospitalar (CTdBem), com as doses obtidas em radiografia panor?mica de uso odontol?gico, ambos realizados em pacientes pedi?tricos e comparar as doses efetivas de radia??o para cristalino, tireoide, gl?ndulas salivares e g?nadas obtidas em TCMS x radiografia panor?mica. M?todos: Foram utilizados dados de dose de radia??o obtidos em exames de pacientes pedi?tricos e jovens de at? 18 anos de idade atendidos no Hospital Universit?rio de Santa Maria (HUSM), que necessitavam de avalia??o odontol?gica por m?todos de diagn?stico por imagem. O valor da estimativa da dose efetiva de radia??o foi obtido por calculo computacional utilizando os dados de CTDI (Computed Tomography Dose Index) e DLP (Dose Lenght Product) do TCMS e os valores de DAP (Dose Area Product) para o equipamento de radiografia panor?mica. Foram considerados os ?rg?os: cristalino, tireoide, gl?ndulas salivares e g?nadas, sendo comparadas as doses efetivas de radia??o obtidas para os diferentes equipamentos. Os exames radiogr?ficos foram realizados utilizando a panor?mica em equipamento de raios-X Instrumentarium OP200, 57-85kV, 2-16mAs e tempo de aquisi??o de aproximadamente 11 segundos. Para a TCMS foi utilizado o Toshiba Aquilion64 utilizando 120kV, 10mAs e tempo de aquisi??o de aproximadamente 6 segundos. Resultados: A compara??o da DLP do protocolo CTdBem com radiografia panor?mica mostrou valores de dose de 28,48mSv e 36,45mSv, respectivamente. Quando comparadas as doses efetivas foram encontrados os valores de dose para gl?ndulas salivares de 0,28mSv e 0,36mSv, para g?nadas de 2,28mSv e 2,92mSv, para tireoide de 0,28mSv e 0,36mSv e para cristalino de 3,42mSv e 4,37mSv. Conclus?o e Relev?ncia Cl?nica: Os autores concluem que as doses totais e tamb?m as doses efetivas de radia??o para cristalino, tireoide, gl?ndulas salivares e g?nadas obtidas em um protocolo otimizado de tomografia computadorizada multislice para uso hospitalar (CTdBem) foram inferiores as doses obtidas em radiografias panor?micas.
15

Massa de forragem, caracter?sticas estruturais e produ??o de leite em capim-marandu sob lota??o intermitente com per?odo de descanso fixo ou vari?vel. / Forage mass, structural characteristics and milk production in Marandu grass under intermittent stocking with fixed or variable rest period.

Anjos, Albert Jos? dos 10 July 2012 (has links)
Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-10-26T11:55:50Z No. of bitstreams: 2 albert_jose_santos.pdf: 942447 bytes, checksum: 8928d3ffa6d78de8e17e1c881d37b5f7 (MD5) license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-10-26T11:56:41Z (GMT) No. of bitstreams: 2 albert_jose_santos.pdf: 942447 bytes, checksum: 8928d3ffa6d78de8e17e1c881d37b5f7 (MD5) license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) / Made available in DSpace on 2015-10-26T11:56:41Z (GMT). No. of bitstreams: 2 albert_jose_santos.pdf: 942447 bytes, checksum: 8928d3ffa6d78de8e17e1c881d37b5f7 (MD5) license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Previous issue date: 2012 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Funda??o de Amparo ? Pesquisa do estado de Minas Gerais (FAPEMIG) / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPq) / O experimento foi conduzido entre 18 de outubro de 2011 e 3 de maio de 2012, no campo experimental da Embrapa Gado de Leite, objetivando-se avaliar dois crit?rios de manejo para o pastejo intermitente em capim-marandu; sendo um com per?odo de descanso fixo e outro com per?odo de descanso vari?vel, conforme a intercepta??o de 95% da radia??o fotossinteticamente ativa (IRFA 95) e suas influ?ncias sobre a massa de forragem, a composi??o morfol?gica, as caracter?sticas estruturais e a produ??o de leite por animal e por ?rea. Em ambos os tratamentos, o per?odo de ocupa??o foi de tr?s dias, almejando-se um res?duo p?s-pastejo de 25 cm de altura. O ajuste da lota??o em fun??o dos alvos de manejo (altura de res?duo) foi feito por meio da t?cnica de ?put and take?. Para avalia??o das caracter?sticas do pasto, o delineamento experimental utilizado foi o de blocos ao acaso, com duas repeti??es de ?rea e tr?s repeti??es dentro de bloco e, para a avalia??o da produ??o de leite, as unidades experimentais utilizadas foram dezesseis vacas Holand?s x Zebu rec?m-paridas, sendo oito por tratamento, as quais foram blocadas em fun??o da produ??o de leite, dias em lacta??o, n?mero de lacta??es, peso vivo e grupo gen?tico. Os dados obtidos foram submetidos ? an?lise de vari?ncia com o PROC MIXED do SAS? e as m?dias foram comparadas pelo teste LSMEANS, ao n?vel de 5% de probabilidade. Menor intervalo entre pastejo (22,8 dias vs. 30 dias), menor altura pr?-pastejo (35,9 cm vs. 42,3 cm) e menor massa de forragem (5.506 kg/ha.ciclo vs. 7.288 kg/ha.ciclo) foram observados para o crit?rio de per?odo de descanso (PD) IRFA 95, em rela??o ao crit?rio de PD fixo. O pasto com PD vari?vel apresentou maior percentual de l?mina foliar (48,31% vs. 41,06%) e menor percentual de material morto (19,00% vs. 25,43%) na massa seca do pr?-pastejo do que o pasto com PD fixo, garantindo com esse crit?rio, maior rela??o l?mina/colmo no pr?-pastejo. Para produ??o de leite, n?o foi observado efeito de crit?rio de per?odo de descanso (14,4 kg/UA vs. 14,0 kg/UA), sendo observado apenas efeito de ciclo de pastejo sobre a produ??o de leite por animal. No entanto, para produ??o de leite por ?rea foram observados os efeitos (P<0,05) da intera??o crit?rio de per?odo de descanso e ciclo de pastejo. Para taxa de lota??o, observou-se efeito (P<0,05) da intera??o crit?rio de per?odo de descanso x ciclo de pastejo. A maior taxa de lota??o foi encontrada no crit?rio de PD IRFA 95. Na m?dia, o crit?rio de PD IRFA 95 foi superior ao crit?rio de PD fixo para a produ??o de leite por ?rea (93,5 3kg/ha.dia vs. 71,3kg/ha.dia). Pastos de capim-marandu manejados com PD baseado na IRFA 95 apresentaram menor altura pr?-pastejo e melhor rela??o l?mina/colmo do que pastos manejados com PD fixo de trinta dias. Al?m disso, ? poss?vel, com a ado??o do crit?rio de PD baseado na IRFA 95, obter maiores taxa de lota??o animal e produ??o de leite por ?rea. Assim, recomendam-se alturas de pr? e p?s-pastejo de 35 cm e 25 cm, respectivamente, para o capim-marandu. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Zootecnia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2012. / ABSTRACT The experiment was conducted from October, 18th, 2011 to May, 3rd, 2012, at the experimental field of Embrapa Gado de Leite, aiming to evaluate two management criteria for intermittent grazing of Marandu grass; one with a fixed period of rest (RP) and another with rest periods varying according to the interception of 95% of photosynthetically active radiation, and their influence on forage production, morphological composition, structural features and the milk yield per cow and per hectare. In both treatments, the occupancy period lasted three days, aiming a 25 cm residue after grazing. The adjustment of stocking in terms of management targets (residue`s heigh) was made using the technique of "put and take". To evaluate the characteristics of the pasture the experimental design was randomized blocks with two plots and three replicates within a block, and the assessment of milk production and experimental units used were 16 Holstein x Zebu cows who had recently delivered , eight per treatment, which were allocated according to milk production, days in lactation, number of lactations, body weight and genetic group. The data were subjected to analysis of variance with PROC MIXED of SAS ? and means were compared by LSMEANS test at the 5% level of probability. Shorter interval between grazing (22.8 vs. 30 days), lower pre-grazing height (35.9 vs. 42.3 cm) and lower yield of total herbage mass (5,506 vs. 7,288 kg / ha./ cycle) were observed for IRFA 95 rest period criteria (RP) relative to fixed RP criteria. The pasture with variable RP had a higher percentage of leaf blade (48.31 vs. 41.06) and lowest percentage of dead material (19.00 vs. 25.43) in the dry mass of the pre-grazing pasture than with the fixed RP, ensuring with that criteria the better relation leaf blade: stem during pre-grazing. For milk production there has not been observed effect of the rest period criteria (14.4 vs. 14.0), being only observed effect of grazing cycle on production of milk per animal. However, for milk production per area there have been observed the effects (P <0.05) of interaction of criterion period of rest and grazing cycle. For stocking rate, there was observed (P <0.05) interaction between the period of rest x grazing cycle criterion. The higher stocking rate was found in the criteria for IRFA 95 RP. On average the IRFA 95 RP mean was higher than the fixed RP criteria set for the milk yield per area (93.5 vs. 71.3). Marandu grass pastures managed with RP based on the IRFA 95 have a lower pre-grazing height and a better relation blade: stem than pastures grazed at 30 days fixed RP. Moreover, it is possible with the adoption of criteria based on the IRFA 95 RP increase stocking rate and milk production per area. Thus, heights of 35 and 25 cm are recommended for pre-and post-grazing of Marandu grass, respectively.
16

Metagenoma de comunidades microbianas expostas ? radia??o natural e a metais

Ferreira, Henrique C?sar de Jesus 25 September 2014 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2015-12-15T17:45:11Z No. of bitstreams: 1 HenriqueCesarDeJesusFerreira_DISSERT.pdf: 3079036 bytes, checksum: 669ef1f5f7345e06f0db2159cfbc3fcd (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2015-12-29T20:46:40Z (GMT) No. of bitstreams: 1 HenriqueCesarDeJesusFerreira_DISSERT.pdf: 3079036 bytes, checksum: 669ef1f5f7345e06f0db2159cfbc3fcd (MD5) / Made available in DSpace on 2015-12-29T20:46:40Z (GMT). No. of bitstreams: 1 HenriqueCesarDeJesusFerreira_DISSERT.pdf: 3079036 bytes, checksum: 669ef1f5f7345e06f0db2159cfbc3fcd (MD5) Previous issue date: 2014-09-25 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Muitas esp?cies se especializaram em viver nos mais variados ambientes existentes demonstrando a not?vel capacidade de adapta??o do mundo microbiano as mais diversas condi??es f?sico-qu?micas. Ambientes expostos ? radia??o natural e a metais s?o escassos ao redor do mundo, apresentando uma microbiota ainda desconhecida. Com um n?mero total estimado entre 4 e 6 x 1030 microrganismos na terra, estes constituem um enorme pool biol?gico e gen?tico a ser explorado. Abordagens metagen?micas, independentes de cultivo, proporcionam uma nova forma de acesso ao potencial gen?mico de amostras ambientais tornando-se uma importante ferramenta para elucida??o de fun??es ecol?gicas, bem como para identifica??o de novas esp?cies e biomol?culas. Neste trabalho, o material gen?tico ambiental de amostras de solo e ?gua do A?ude Boqueir?o de Parelhas-RN, sob influ?ncia de radia??o natural e da presen?a de metais, foi extra?do, pirosequenciado, e as sequ?ncias geradas foram analisadas atrav?s de programas de bioinform?tica (MG-RAST e STAMP). Perfis taxon?micos comparativos de ambas as amostras mostraram alta abund?ncia do Dom?nio Bacteria, seguida por uma pequena parcela atribu?da aos Dom?nios Eucaryota, Archaea e V?rus. Proteobacteria, Actinobacteria e Bacterioidetes foram os filos que mostraram maior domin?ncia em ambas as amostras. Importantes g?neros e esp?cies associados ? resist?ncia aos agentes estressores encontrados na regi?o foram observados. Sequ?ncias relacionadas ? replica??o e reparo do DNA, ao estresse oxidativo e estresse pelo calor e a resist?ncia a compostos t?xicos foram observadas, mostrando uma importante rela??o entre a microbiota e seu perfil metab?lico, influenciada pelas vari?veis ambientais regionais. Os resultados encontrados neste estudo adicionam valiosos e in?ditos dados sobre a composi??o de comunidades microbianas nestas regi?es. / Many species have specialized to live in the most varied existing environments showing the remarkable adaptability of the microbial world the most diverse physicochemical conditions. Environments exposed to natural radiation and metals are scarce around the world, presenting a microbiota still unknown. With a total number estimated between 4 and 6 x 1030 microrganisms on earth, they constitute an enormous biological and genetic pool to be explored. Metagenomic approach independent of cultivation, provides a new form to access to the potential genomic environmental samples becoming a powerful tool for the elucidation of ecological functions, metabolic profiles, as well as to identify new biomolecules. In this context, the genetic material of environmental soil and water samples from A?ude Boqueirao Parelhas-RN, under the influence of natural radiation and the presence of metals, was extracted, pirosequencing and the generated sequences were analyzed by bioinformatics programs (MG-RAST and STAMP). Taxonomic comparative profiles of both samples showed high abundance of Domain Bacteria, followed by a small portion attributable to Eucaryota Domains, Archaea and Viruses. Proteobacteria, Actinobacteria and Bacterioidetes phyla showed the greater dominance in both samples. Important genera and species associated with resistance to various stressors found in region were observed. Sequences related to oxidative and heat stress, DNA replication and repair, and resistance to toxic compounds were observed, suggesting a significant relationship between the microbiota and their metabolic profile, influenced by regional environmental variables. The results of this study add valuable and unpublished data on the composition of microbial communities in these regions
17

Uma experi?ncia de inser??o de astronomia e f?sica moderna no ensino m?dio a partir do sol

Silva, Sandra Maria da 27 July 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-03-27T18:25:54Z No. of bitstreams: 1 SandraMariaDaSilva_DISSERT.pdf: 9941492 bytes, checksum: eab91820e15a82d07826efacf3dc1f56 (MD5) / Approved for entry into archive by Monica Paiva (monicalpaiva@hotmail.com) on 2017-03-27T18:35:13Z (GMT) No. of bitstreams: 1 SandraMariaDaSilva_DISSERT.pdf: 9941492 bytes, checksum: eab91820e15a82d07826efacf3dc1f56 (MD5) / Made available in DSpace on 2017-03-27T18:35:13Z (GMT). No. of bitstreams: 1 SandraMariaDaSilva_DISSERT.pdf: 9941492 bytes, checksum: eab91820e15a82d07826efacf3dc1f56 (MD5) Previous issue date: 2015-07-27 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / A presente pesquisa tem como objetivo central promover a melhoria do ensino de f?sica na Escola Estadual ?Amaro Cavalcante? (EEAC) por meio de uma proposta did?tica que contemple a inser??o de conceitos de Astronomia e de F?sica Moderna a partir do Sol. O trabalho segue uma abordagem predominantemente qualitativa e se caracteriza como uma pesquisa-a??o com interven??o em sala de aula. Os sujeitos da pesquisa foram os alunos da 3? s?rie A e 3? s?rie B do ensino m?dio da EEAC. Os instrumentos de coleta de dados foram constitu?dos pela observa??o participante natural, aplica??o de quest?es abertas e pela an?lise das atividades desenvolvidas durante a execu??o dos planos de aulas (pr?-testes e exerc?cios). O produto educacional foi constru?do a partir da elabora??o de unidades did?ticas de aulas que enfatizam o estudo do Sol, do Sistema Solar, da radia??o do corpo negro e da Lei de Planck. Os alunos, sujeitos da pesquisa, j? tinham conhecimentos pr?vios sobre o Sol o que serviu como ?ncora para a amplia??o e inser??o de conte?dos de Astronomia e F?sica Moderna. As informa??es oriundas do campo de pesquisa foram interpretadas ? luz da an?lise de conte?do proposta por Bardin (2011).
18

Emiss?o de radia??o eletromagn?tica n?o ionizante na cidade do Natal: caracteriza??o, avalia??o e modelamento com base na intensidade do campo el?trico e na taxa de exposi??o

Pinheiro, Fred Sizenando Rossiter 17 December 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-11-22T19:39:17Z No. of bitstreams: 1 FredSizenandoRossiterPinheiro_TESE.pdf: 2936282 bytes, checksum: e043d67f2ec70c4303eadd2ce8383354 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-11-22T23:29:37Z (GMT) No. of bitstreams: 1 FredSizenandoRossiterPinheiro_TESE.pdf: 2936282 bytes, checksum: e043d67f2ec70c4303eadd2ce8383354 (MD5) / Made available in DSpace on 2017-11-22T23:29:37Z (GMT). No. of bitstreams: 1 FredSizenandoRossiterPinheiro_TESE.pdf: 2936282 bytes, checksum: e043d67f2ec70c4303eadd2ce8383354 (MD5) Previous issue date: 2015-12-17 / O surgimento da Telefonia Celular, a partir dos anos 1990, e a constru??o fren?tica de torres nas cidades assustou a popula??o, levou a comunidade cient?fica mundial e os ?rg?os de controle ambiental a dar maior aten??o ?s ondas eletromagn?ticas n?o ionizantes. Um estado pobre como o Rio Grande do Norte evoluiu a quantidade de celulares em opera??o de 340 mil no ano 2002 para 4,6 milh?es em 2014. No RN a quantidade de linhas celulares supera a pr?pria popula??o, com uma densidade de 128,98 acessos para cada 100 habitantes. Natal, a capital do RN, com 850 mil habitantes, j? possui 882 Esta??es R?dio Base dos Sistemas celulares em 167,26 km2 de ?rea urbana. O objetivo do presente trabalho ? fazer um diagn?stico sobre a exposi??o ? radia??o eletromagn?tica n?o ionizante em toda ?rea urbana da Cidade. A metodologia usada levou em conta medi??es de intensidade das radia??es feitas em 160 diferentes pontos da cidade. As medi??es foram feitas na faixa de 88MHz a 2.400 MHz. Os servi?os de telecomunica??es avaliados na pesquisa foram: TV (Broadcasting), R?dio FM (Broadcasting), Sistemas Celulares e WLAN (IEEE 802.11bg).Foram considerados para compara??o os limites de exposi??o do ICNIRP (InternationalCommission on Non IonizationProtection), par?metros: ?Intensidade de Campo El?trico? e ?Raz?o de Exposi??o? (ER). Resultados: de acordo com as medi??es realizadas, 48.48 % da exposi??o eletromagn?tica outdoor na cidade do Natal decorre da radia??o emitida pelos transmissores de TV. Da mesma forma, constatou-se que, em 77,2 % dos pontos pesquisados, a intensidade do campo el?trico gerada pelas TVs supera todos os demais servi?os de telecomunica??es, inclusive a Telefonia Celular. A Taxa de Exposi??o (ER) m?dia de Radia??o N?o Ionizante verificada para a faixa de frequ?ncia pesquisada foi de 4,43. 10 -3, enquanto o valor m?ximo foi de 7,67. 10-2. Foi desenvolvido modelo para estimativa do Campo El?trico gerado pelos transmissores das TVs em qualquer ponto da cidade. Utilizouse a T?cnica Estat?stica de Regress?o Multivariada, a partir das 160 amostras. As equa??es finais obtidas permitem as estimativas com grau de precis?o R2 superior a 0,9, p<0,1. Constatou-se que o expoente de atenua??o para propaga??o de RF na cidade varia entre 2,8 e 3,8. A exposi??o eletromagn?tica ? RNI em ambientes outdoor em Natal est? em n?veis abaixo dos limites de seguran?a definidos pelo ICNIRP e ANATEL. Os servi?os que mais contribuem para RNI em Natal s?o: 1-TV, 2-Sistema Celular e 3-R?dios FMs. / The electromagnetic waves used in the telecommunication systems until the 1980?s were considered by the governments environmental control organs as apparently ?clean? forms of energy, whose effects weren?t considered any harmful to people?s health. The development of the mobile cellular telecommunication, beginning in the 1990?s, and the frenetic construction of antennas in the cities? urban areas scared the population in general and turned the attention of the world?s scientific community to the theme. In a poor Brazilian State, such as Rio Grande do Norte ? RN (GDP:R$ 51,4 billion in 2013) , the amount of cellular phones in operation went from 340.000 in 2002 to 4.6 million phones in 2014. In RN the number of cellular lines overcomes its own population, with a density of 128.98 accesses for each 100 inhabitants. Natal, the capital city of the State, with 850.000 inhabitants, already has 885 radio base stations of the cellular systems in 167.26 km? of urban area. The data is from ANATEL (august 2015). The objective of this work is to make a diagnosis about the actual situation of the emission of non-ionizing electromagnetic radiation in all urban area of the city of Natal. The methodology used took into account measurements of the intensity of the radiation taken in 160 different sites throughout the city. This radiation was measured in the range of 88MHz to 2.400 MHz. The collected data was compared to the limits of exposure of the ICNIRP (International Commission on Non Ionization Protection). The ICNIRP parameters used as reference were: ?intensity of electric field? and ?exposure ratio?. The telecommunication services researched were: TV broadcasting, FM radio broadcasting, cellular systems and WLAN (IEE 802.11bg). The obtained results allowed the drawing of a map comparing the data between the measured values and the limits of exposure to RNI defined by ICNIRP and ANATEL. The evaluation criteria used was the parameters Intensity of Electric Field and Exposure Ratio (ER). Results: according to the measurements taken, 48.48% of the outdoor electromagnetic exposure in the municipality of Natal are originated from TV transmitters. Similarly, in 77.2% of the researched locations, the intensity of the electric field originated from TVs overcomes all the rest of the wireless telecommunication services, including the cellular system. Based on the information that the radiation emitted by the TV transmitters is the most relevant in the city, a model to estimate the intensity of the electric field resulting from this service in any point in town was developed. This model was developed based on multivariate regression techniques. The final equations obtained allowed the estimative of the electric field with a level of precision R2> 0,9 and p<0,1. It was found that the exponent RF propagation attenuation in Natal varies between 2.6 and 2.8.The average Exposure Rate (ER) to NIR observed in the researched frequency rate was of 4.43.10-3, while the maximum value was of 7.67. 10- Conclusions: The results of the study demonstrated that the levels of electromagnetic exposure to NIR in outdoor environments in the city of Natal are lower than the security limits set by ICNIRP and ANATEL. The services that contribute most to NIR in Natal are 1-TV, 2- Cellular System and 3-FM Radios.
19

An?lise da densidade ?ssea e da atenua??o do feixe de raios X nos tecidos moles, em mand?bula de coelhos submetidos ? lasertarapia, durante a distra??o osteog?nica

Cenci, Rodrigo Alberto 08 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:09Z (GMT). No. of bitstreams: 1 438173.pdf: 1856345 bytes, checksum: 88a20c5de7a402c873dcfd4ecbe6460d (MD5) Previous issue date: 2012-03-08 / INTRODUCTION: Cone-beam computed tomography (CBTC) provides detailed information about the amount and quality of new bone formed during distraction osteogenesis (DO). The density of the lengthened bone is measured based on different levels of gray found in the images. The use of CBTC therefore allows to perform a quantitative analysis of bone density and, thus, to measure the level of X-ray attenuation by soft tissues. OBJECTIVES: To assess, via CBTC, newly formed bone in mandibles of rabbits treated with DO under the biomodulating effects of AsGaAl infrared laser radiation (&#955;=830 nm, 40 mW), applied during the activation phase. The distracted area was assessed based on the gray levels shown on images and observing the influence of soft tissues on X-ray attenuation. MATERIALS AND METHODS: Ten rabbits were used (two experimental groups and one control group). The two experimental groups were treated with DO and low-level laser therapy. Rabbits in experimental group A were killed 11 days after the beginning of DO, and those in experimental group B, after 21 days of DO. CBTC images were obtained from the mandibles of the ten rabbits with soft tissues and subsequently (after dissection) without soft tissues. This comparison allowed to analyze the influence of soft tissues on X-ray attenuation, and consequently on the decrease in gray levels observed in the tomographs of rabbits treated with DO. RESULTS: The presence of soft tissues increased X-ray attenuation, resulting in a decrease in the levels of gray observed in three-dimensional CBCT images of mandibular bone tissue of the rabbits before and after soft tissue removal. The area of the mandibles treated with DO presented higher levels of gray in rabbits killed at 21 days. CONCLUSIONS: CBCT allowed to assess bone density variation in areas treated with DO. The presence of soft tissues contributes to decrease the levels of gray in three-dimensional CBCT bone tissue images of the ten rabbits assessed. This occurs due to the absorption of X-rays by soft tissues studied by tomography. We found that bone density in the area treated with DO, as observed on tomography, increased in direct proportion to the bone maturation period after the activation phase in DO, based on the gray levels observed. / INTRODU??O: A tomografia computadorizada do tipo Cone-beam (TCCB) fornece informa??es detalhadas sobre a qualidade e a quantidade de osso neoformado pela distra??o osteog?nica (DO). Permite mensurar a densidade do osso alongado, por meio da avalia??o dos tons de cinza. Desta forma, pode-se realizar uma an?lise quantitativa da densidade ?ssea, dimensionando a atenua??o dos feixes de raios X pelos tecidos moles nas imagens. OBJETIVOS: Avaliar, por interm?dio da TCCB, o osso mandibular neoformado em mand?bulas de coelhos submetidos ? DO, sob efeito biomodulat?rio da irradia??o por laser infravermelho AsGaAl (&#955;=830 nm, 40 mW), aplicado durante a fase de ativa??o do aparelho distrator. A ?rea da distra??o ? avaliada pelos n?veis de cinza das imagens, observando tamb?m a influ?ncia dos tecidos moles na atenua??o dos feixes de raios X. MATERIAIS E M?TODOS: Dez coelhos foram utilizados (dois grupos experimentais e um grupo controle). Os grupos experimentais foram submetidos ? DO e ? terapia a laser de baixa potencia (LLLT). Os coelhos do grupo experimental A foram mortos ap?s 11 dias do in?cio da DO e os coelhos do grupo experimental B, mortos ap?s 21 dias do in?cio da DO. Os 10 coelhos foram submetidos a tomografia com tecidos moles e posteriormente dissecados e submetidos a tomografia sem tecidos moles. Assim, foi poss?vel analisar a influ?ncia dos tecidos moles em coelhos submetidos ? DO na atenua??o dos feixes de raios X e, consequentemente, na diminui??o dos valores de n?veis de cinza observados na imagem tomogr?fica. RESULTADOS: A presen?a dos tecidos moles aumenta a atenua??o dos feixes de raios X contribuindo na diminui??o dos valores de n?veis de cinza, observados na imagem do tecido ?sseo em 3D, na mand?bula dos 10 coelhos submetidos a tomografia, antes e ap?s a remo??o dos tecidos moles. A ?rea das mand?bulas submetidas ? distra??o apresentaram valores superiores de cinza, nos coelhos mortos ap?s 21 dias do in?cio da DO. CONCLUS?ES: Com tom?grafos do tipo Cone-beam, foi poss?vel avaliar a varia??o da densidade ?ssea em ?reas submetidas ? DO. A presen?a dos tecidos moles contribui na diminui??o dos valores de n?veis de cinza observados nas imagens do tecido ?sseo dos 10 coelhos em 3D. Isto ocorre devido ? absor??o do feixe de raios X pelos tecidos moles submetidos a tomografia. Tamb?m observou-se que a densidade ?ssea na ?rea da distra??o, visualizada na tomografia, aumenta proporcionalmente ao per?odo de matura??o ?ssea ocorrido ap?s a fase de ativa??o da DO, conforme observa??o dos valores de cinza obtidos.
20

Reparo do tecido ?sseo irradiado ap?s utiliza??o de beta fosfato tric?lcico associado a hidroxiapatita : estudo em ratos

Grandi, Gisela 28 September 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:19Z (GMT). No. of bitstreams: 1 447185.pdf: 1490319 bytes, checksum: 062b3580e76c16931c597b9792a749c2 (MD5) Previous issue date: 2012-09-28 / The biomaterial made up of 60% hydroxyapatite (HA) and 40% beta tricalcium phosphate (&#946;-TCP) (Bone Ceramic?, Straumann S.A. Zurich, Switzerland) is a synthetic bone graft, biocompatible, whose biphasic composition enables it to bear the bone newly formation and maintain the tissue mechanical stability. The present study has evaluated the repair in critical bone defects, made on rats calvaria, filled with that biomaterial before and after therapy with ionizing radiation. The sample was formed by 33 Wistar rats distributed into two experimental groups that received 12 Gy radiation (single dose), and a control group. In the first experimental group (N=12) the fabrication and filling of the calvaria defect were performed two weeks after radiotherapy (pos-radiotherapy group). In the second group (n=12) the fabrication and filling of the calvaria defect were performed two weeks before radiotherapy (pre-radiotherapy group). The animals in the control group (n=9) were submitted to the same surgical procedures but did not receive any ionizing radiation therapy. The animals were killed 12 weeks after surgical procedures. In all groups a close contact between the biomaterial granules and the newly formed bone tissue was observed, as well as absence of necrosis. No statistically relevant differences were detected in the histomorphological analysis of the three groups with regards to the percentage of newly formed bone tissue in the defects. There were also no differences among the groups with regards to the number of osteoblasts, osteoclasts and inflammatory cells. The VEGF (Vascular Endotelial Growth Factor) (p<0.001) immunodetection percentage, and the mineral density in the defect site (p=0.020) were higher in the control group. Thus, it can be concluded that the biomaterial made up of HA and &#946;-TCP promotes osteoconduction in the irradiated tissue similarly to what occurs in the non-irradiated tissue. Moreover, there is no difference regarding the moment the ionizing radiation is employed, that is, whether before or after applying the biomaterial. / O biomaterial constitu?do por 60% de hidroxiapatita (HA) e 40% de beta fosfato tric?lcico (&#946;-TCP) (Bone Ceramic?, Straumann S. A. Zurich, Su??a) ? um enxerto ?sseo sint?tico, biocompat?vel, cuja composi??o bif?sica fornece capacidade de suportar a neoforma??o ?ssea e manter a estabilidade mec?nica do tecido. No presente estudo foi avaliado o reparo em defeitos ?sseos cr?ticos, confeccionados em calv?ria de ratos, preenchidos com esse biomaterial, antes e ap?s a terapia com radia??o ionizante. A amostra foi constitu?da por 33 ratos Wistar distribu?dos em dois grupos experimentais, que receberam 12 Gy de radia??o em dose ?nica, e um grupo-controle. No primeiro grupo experimental (n=12) a confec??o e o preenchimento do defeito na calv?ria foram realizados duas semanas ap?s a radioterapia (grupo p?s-radioterapia). No segundo grupo (n=12) a confec??o e o preenchimento do defeito ?sseo ocorreram duas semanas antes da radioterapia (grupo pr?-radioterapia). Os animais do grupo-controle (n=9) foram submetidos aos mesmos procedimentos cir?rgicos, no entanto, n?o receberam terapia com radia??o ionizante. Os animais foram mortos 12 semanas ap?s os procedimentos cir?rgicos. Em todos os grupos foi observado ?ntimo contato entre o tecido ?sseo neoformado e os gr?nulos do biomaterial, bem como aus?ncia de necrose. Na an?lise histomorfom?trica n?o foram detectadas diferen?as estatisticamente significativas entre os tr?s grupos quanto ao percentual de tecido ?sseo neoformado nos defeitos. Tamb?m n?o houve diferen?as significativas entre os grupos quanto ao n?mero de osteoblastos, osteoclastos e c?lulas inflamat?rias. O percentual de imunodetec??o do VEGF (fator de crescimento endotelial vascular) (p<0,001) e a densidade mineral na regi?o dos defeitos (p=0,020) foram superiores no grupo-controle. Pode-se concluir que o biomaterial constitu?do por HA e &#946;-TCP promove osteocondu??o no tecido irradiado de forma semelhante a que ocorre no tecido n?o irradiado. Al?m disso, n?o h? diferen?as quanto ao momento do emprego da radia??o ionizante, ou seja, se antes ou ap?s a aplica??o do biomaterial.

Page generated in 0.0563 seconds