• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 614
  • 24
  • 10
  • 7
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 670
  • 424
  • 152
  • 94
  • 89
  • 87
  • 86
  • 82
  • 66
  • 66
  • 65
  • 62
  • 59
  • 59
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
601

Impacto da PET/CT no câncer de pulmão não-pequenas células: contribuição no delineamento tumoral

Almeida, Taynná Vernalha Rocha 06 August 2013 (has links)
Introdução: A definição do volume-alvo macroscópico, principalmente referente a casos de câncer de pulmão, exige o maior número de informações possíveis no que diz respeito à localização, extensão e mobilidade tumoral. A literatura demonstra um importante avanço quando utilizada imagens metabólicas como é o caso da tomografia por emissão de pósitron/tomografia computadorizada (PET/CT), porém a sua aplicação nos planejamentos radioterápicos ainda é muito discutida devido ao seu grau de complexidade. Objetivos: Avaliar o impacto da PET/CT no delineamento tumoral em casos de câncer de pulmão não-pequenas células (CPNPC) e linfonodos regionais. Materiais e Métodos: Foram selecionados retrospectivamente estudos de PET/CT de 26 casos de câncer de pulmão. Todos foram confirmados por biópsia, sendo em sua totalidade CPNPC. Todos os estudos foram realizados em um equipamento de PET/CT dedicado com parâmetros de aquisição idênticos. A interpretação das imagens e posterior delineamento foram realizados por dois médicos experientes, um radioterapeuta e um nuclear/radiologista. Os parâmetros ótimos de visualização foram pré-definidos, sendo mandatórios para os delineamentos. Os delineamentos foram realizados em duas etapas principais. A primeira relacionada ao desenho tumoral somente pela CT e a segunda, após no mínimo duas semanas de descanso visual, referindo-se ao desenho tumoral pela PET/CT. Somente o volume tumoral macroscópico (GTV) e os linfonodos regionais aumentados ou PET positivos foram delineados. Índices de conformidades (IC) foram calculados, tanto interobservadores (11 casos), quanto intra-observador (26 casos). Para a comparação entre observadores e entre delineamentos em relação ao volume, foi considerado o teste não-paramétrico de Wilcoxon. As comparações em relação ao IC foram feitas usando-se o teste t de Student para amostras pareadas. Em todos os testes, valores de p <0,05 indicaram significância estatística. Os dados foram analisados com o programa computacional SPSS® Statistics 17.0 (EUA). Resultados: A análise dos dados demonstrou diferença significativa entre os volumes médios delineados na CT e na PET/CT (p = 0,02), com evidente redução volumétrica no delineamnto por PET/CT. Houve diferença significativa entre os volumes CT delineados pelos dois observadores (p = 0,03) e uma tendência a apresentar diferença significativa entre volumes PET/CT (p = 0,05). A avaliação volumétrica intraobservador foi significativa (p < 0,01) apenas para o médico nuclear/radiologista, com redução de até 51% do volume CT e uma relação entre modalidades de 2,11 ± 0,22. Na análise dos IC, não houveram diferenças significativas entre as duas modalidades de imagem (p = 0,598). A análise dos IC intra-observadores demonstrou que para o radioterapeuta a PET/CT apresenta um impacto de 46% (IC médio = 0,54 ± 0,06), já para o nuclear/radiologista, o impacto foi de 65% (IC médio = 0,35 ± 0,06), representando uma diferença significativa (p = 0,03) em relação ao IC entre o médicos observadores. Para a análise linfonodal a PET/CT apresentou importante diferença na visualização de linfonodos, alterando 10 dos 26 casos, sendo 9 para a positividade apenas na fusão. Conclusão: A PET/CT apresentou significativo impacto no desenho do GTV e linfonodos regionais para casos de CPNPC. / Introduction: The definition of gross target volume, especially concerning cases of lung cancer, requires the greatest amount of information possible with regard to location, tumor size and tumor mobility. The literature demonstrates an important advancement using metabolic images such as PET/CT, however, its application in radiotherapy planning is still controversial due to its complexity. Objectives: To assess the impact of PET/CT in tumor delineation in cases of non-small cell lung cancer and regional lymph nodes as additional findings. Materials and Methods: Retrospectively studies of PET/CT of 26 lung cancer cases were selected. All were confirmed by biopsy, in its entirety NSCLC. All studies were performed on a PET/CT with dedicated acquisition identical parameters. Image interpretation and subsequent delineation were performed by two experienced physicians, one radiotherapist and the another nuclear/radiologist. The optimal parameters display were pre-defined, being mandatory for the designs. Each case received an identification of three random letters to access the medical images to be analyzed. The delineation was made in two main steps. The first reference to the drawing only in tumor CT and the second, after two weeks of visual rest, referring to the drawing on tumor PET/CT. Only the gross tumor volume (GTV) and regional lymph nodes were enlarged or PET + outlined. Conformity index (CI) were calculated both interobserver (11 cases), and intra-observer (26 cases). For comparison between observers and between designs in relation to the volume, was considered the nonparametric Wilcoxon test. Comparisons regarding the conformity index were made using the Student t test for paired samples. To assess the degree of agreement regarding positive lymph nodes were estimated with kappa coefficients of agreement. In all tests, p values <0.05 were considered statistically significant. Data were analyzed with the software SPSS Statistics 17.0 (USA). Results: Data analysis showed significant difference between the average volumes delineated on CT and PET/CT (p = 0.02), with obvious volume reduction. Significant difference between the volumes delineated by CT observars medical distinct classes (p = 0.03) and a tendency to present significant difference between volumes PET / CT (p = 0.05). The intraobserver volumetric evaluation was significant (p <0.001) only for observer 2, being the nuclear medicine physician / radiologist, reducing up to 51% of the volume CT and a relationship between methods of 2.11 ± 0.22. In the analysis of CI, there were no significant differences between the two imaging modalities (p = 0.598).CI analysis showed that intra-observer to observer 1 PET / CT has an impact of 46% (average CI = 0.54 ± 0.06). The viewer 2, the impact was greater, 46% (average IC = 0.39 ± 0.03), representing a difference of opinion regarding the CI (p = 0.03) between the medical classes. To regional lymph nodes with PET/CT revealed an important difference in the visualization of lymph nodes, changing 10 of the 26 cases, 9 to positivity only in the image fusion.Conclusion: PET/CT has a significant impact on the design of the GTV and regional lymph nodes in cases of NSCLC.
602

Estudo e desenvolvimento de algoritmos de esqueletização com aplicação em redes vasculares ósseas

Abreu, Andrêssa Finzi de 02 September 2016 (has links)
Apesar de ser uma técnica muito difundida, a radioterapia pode causar danos ao reparo ósseo, como por exemplo, a diminuição da vascularização. Entretanto, a rede vascular óssea tem um papel importante na capacidade de regeneração dos ossos, pois fornece oxigênio e nutrientes essenciais, logo, ferramentas que auxiliem a análise dessas redes são importantes para o estudo de diversas terapias que têm influência sobre o tecido ósseo. Para analisar tais redes foi feita a reconstrução tridimensional de imagens coletadas a partir do seccionamento dos fêmures de um rato que recebeu doses de radiação em seu fêmur esquerdo, enquanto que o direito não foi irradiado sendo, portanto, utilizado para controle. Com o objetivo de auxiliar a análise desses volumes foi utilizada a técnica de esqueletização, que tem a finalidade de diminuir a quantidade de informação dos objetos e tornar a análise mais precisa e eficiente. Entretanto, existem diversos tipos de algoritmos esqueletização, sendo eles, de Afinamento, Geométricos, baseados na Transformada Distância, em Campo de Força e em Propagação de Ondas. Com o objetivo de analisar qual deles produz melhores resultados em volumes de redes vasculares foi escolhida uma implementação de cada tipo para ser testada e analisada em volumes pertencentes às redes vasculares. Além disso, o algoritmo escolhido para representar os métodos baseados em Propagação de Ondas foi desenvolvido e proposto neste trabalho exclusivamente para extrair canais de redes vasculares. Por fim, os esqueletos das redes vasculares conseguiram reproduzir com clareza a rede estudada e possibilitaram a conclusão de análises relacionadas ao impacto da radioterapia sobre a topologia vascular. Além disso, a comparação entre os tipos de algoritmos de esqueletização possibilitou um estudo aprofundado sobre o tema e sobre as diversas características de esqueletos de curva que podem ser usadas para classificar e comparar os métodos presentes na literatura. / Although a common technique, the radiotherapy can cause damage to bone repair, such as decrease in vascularization. However, the bone vascular network has an important role in capacity of bone regeneration because it provides oxygen and nutrients, therefore, tools that helps the analysis of vascular networks are important for the study of various therapies that have influence on the bone repair. In order to analyze such networks, we mande three-dimensional reconstructions of collected images from the sectioning of a mouse femurs that received radiation doses in the left femur, while the right was not irradiated and used for control. In order to aid the analysis of these volumes, skeletonization techniques were used to decrease the amount of the objects’s information and make the analysis more accurate and efficient. However, there are several types of skeletonization algorithms which uses different approachs as based on Forcefield, Thinning, based on Distance Transform, Geometrical and based on Wave Propagation. In order to analyze which of them produces the best results in vascular networks, an implementation of each type was chosen to be tested and analyzed in vascular network volumes. Furthermore, the algorithm chosen to represent the methods based on Wave Propagation was developed and proposed in this work exclusively to extract vascular networks. Finally, the skeletons of the vascular networks reproduced the network studied with clarity and enabled the conclusion of analysis related to the radiation impact on vascular topology. In addition, the comparison between the types of skeletonization algorithms allowed a deep study about the subject and on the various curve skeletons characteristics that can be used to classify and compare the methods in the literature. / Dissertação (Mestrado)
603

Cofilina-1 (CFL-1) correlaciona-se à sobrevida mediana em pacientes com carcinoma de pulmão não de pequenas células tratados com radioterapia

Leal, Matheus Hermes January 2016 (has links)
Base teórica: O câncer de pulmão é uma doença com alta incidência e mortalidade, cujo prognóstico permanece discreto apesar do melhor entendimento da doença nas últimas décadas. A radioterapia tem papel terapêutico em todos os estágios da doença. A expressão da cofilina-1, uma proteína relacionada à mobilidade celular, determinou maior radiossensibilidade a células de adenocarcinoma brônquico em estudos in vitro, porém pior sobrevida em estádios iniciais Objetivo: Avaliar se a expressão da cofilina-1 interfere na sobrevida e no controle local em pacientes com câncer de pulmão submetidos a tratamento com radioterapia definitiva Métodos: Foram avaliados pacientes com câncer de pulmão não pequenas células, com estádios I–IV, que receberam radioterapia exclusiva ou combinada com quimioterapia, dirigida à neoplasia brônquica, na unidade de radioterapia do HCPA, nos anos de 2009 a 2015. Todos os pacientes tiveram a expressão de cofilina-1 aferida e foram distribuídos conforme os níveis de expressão de cofilina-1 utilizando-se de protocolo específico. Os prontuários foram avaliados retrospectivamente para calcular a sobrevida mediana. A progressão foi verificada através de avaliação de tomografias de tórax de controle. Resultados: Foram avaliados 45 pacientes neste estudo. A sobrevida mediana de todos os pacientes foi de 11,3 meses e a sobrevida global em 5 anos de 17,3%. Pacientes com expressão média ou alta de cofilina-1 tiveram maior mortalidade quando comparados com pacientes com baixa expressão (respectivamente, HR 1,628, IC95 1,137-8,287 e HR 1,59 IC95 1,105-7,342). Não houve diferença significantemente estatística entre controle local e expressão de cofilina-1. Conclusão: A expressão de cofilina-1 está associada à sobrevida em pacientes com carcinoma brônquico tratados com radioterapia e existe uma tendência a melhor controle local com baixa expressão. Nossos resultados sugerem um novo campo a ser explorado no manejo do carcinoma de pulmão localmente avançado, utilizando-se dos níveis de cofilina-1. / Background: Lung cancer is a disease with high incidence and mortality, whose prognosis remains poor despite a better understanding of the disease in the last decades. Radiotherapy plays a therapeutic role in all stages of disease. The expression of cofilin-1, a protein related to cellular mobility, determined greater radiosensitivity to lung adenocarcinoma cells in in vitro studies, but worse survival at initial stages. Objective: To evaluate if the expression of cofilin-1 modified survival and local control in lung cancer patients submitted to definitive treatment with radiotherapy. Methods: Patients with non-small cell lung cancer with stage IIV who received radiotherapy alone or combined with chemotherapy for lung cancer at the HCPA radiotherapy unit from 2009 to 2015 were evaluated. All patients had the expression of measured cofilin-1 evaluated and were distributed by cofilin-1 expression according to specific protocol. The medical records were retrospectively evaluated to estimate median survival. The progression was verified through evaluation of control chest tomography. Results: 45 patients were assessed in this study. The median survival of all patients was 11.3 months and the 5-year overall survival was 17.3%. Patients with medium or high expression of cofilin-1 had higher mortality rates when compared to patients with low expression (HR, 1,628, CI95, 1,137-8,287 and HR, 1.59, CI95, 1,105-7,342). There was no statistically significant difference between local control and cofilin-1 expression. Conclusion: cofilin-1 expression is associated with survival in patients with lung cancer treated with radiotherapy and there is a tendency for better local control with low CFL1 expression. Our results suggest a new field to be explored in the management of locally advanced lung carcinoma, using cofilin-1 expression levels.
604

Study and evaluation of correction factors applied to ionization chambers in radiotherapy photon beams / Estudo e avaliação de fatores de correção aplicados a câmaras de ionização em feixes de fótons radioterápicos.

Cristiano Queiroz Melo dos Reis 30 July 2015 (has links)
The use of a beam quality correction factor,kQ, is needed in dosimetry of radiotherapy beams for correcting differences between chamber responses at the calibration beam quality, Q0 and at the quality beam of the user, Q. The purpose of this study is to determine the beam quality correction factor for the NE2571 ionization chamber widely used in radiotherapy and its dependence with the stopping-power and the chamber perturbation factors. In addition, an investigation of the use of parallel plate chambers for determining surface doses in photon beams is also performed using the EGSrnc Monte Carlo code system. Results obtained with PENELOPE show that simulations with phase-space files appropriately scored can be up to ten times shorter than using a full spectrum in the input-file. Values of kQ, and its components show good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Values of kQ and absorbed dose to water conversion factors obtained with egs_chamber user code for parallel plate chambers are also provided with maximum statistical uncertainty of 0.7%. Therefore, the results obtained are expected to contribute with improving dosimetry protocols and the quality of life of radiotherapy patients. / O uso de uma fator de correção para a qualidade do feixe, kQ, é necessário em dosimetria de feixes radioterápicos para a correçãoo das diferenças entre a resposta de câmaras de ionização nas qualidades do feixe de calibração, Q0 e do usuário Q. O propósito deste trabalho consiste em determinar o fator de correção da qualidade de feixe para a câmara de ionização NE2571 amplamente utilizada em radioterapia e sua dependência com o stopping-power e os fatores de perturbação da câmara. Além disso, uma investigação do uso de câmaras de placas paralelas para determinar doses na superfície em feixes de fótons é também realizada usando o sistem de códigos em Monte Carlo EGSnrc. Resultados obtidos com o PENELOPE mostram que simulações usando phase-space, podem ser cerca de dez vezes menos longa do que simula ções usando um espectro completo no arquivo de entrada. Valores de kQ e suas componentes mostraram boa concordncia com dados publicados na literatura e são fornecidos com incertezas estatísticas típicas de 0.2%. Valores de kQ e fatores de conversão pra dose absorvida na água obtidos para as câmaras de placas paralelas com o código de usuário egs_chamber são também fornecidos com incerteza estatística máxima de 0.7%. Deste modo, espera-se que os resultados obtidos possam contribuir com o aperfeiçoamento de protocolos de dosimetria e com a qualidade de vida de pacientes radioterpicos.
605

Dosimetria 3D de um tratamento simulado de próstata na presença de próteses femorais metálicas. / 3D dosimetry of a simulated prostate treatment in the presence femoral prostheses.

Diana Maritza Cuevas Rojas 24 January 2017 (has links)
Historicamente a radioterapia é divida em radioterapia externa, braquiterapia e radioisotopoterapia sistemática. As diferenças entre as três está no posicionamento da fonte de radiação com respeito ao corpo humano. Na radioterapia externa a fonte fica a uma certa distância do paciente, já no caso da braquiterapia as fontes podem ser inseridas dentro de cavidades do corpo ou implantadas diretamente nos tecidos. Na radioisotopoterapia sistemática isótopos radiativos são administrados por via oral ou venosa. Dessas três a radioterapia externa é a mais usada pois, ela permite realizar planejamentos de radioterapia em três dimensões (3D), partindo inicialmente de uma tomografia computadorizada da região do tumor. O planejamento baseado na tomografia computadorizada permite que a distribuição da radiação nos tecidos seja feito com mais precisão evitando assim, que os tecidos sadios sejam afetados. Nesse trabalho a radioterapia externa convencional, foi implementada e executada para um tratamento de próstata com implantes metálicos, usando 4 campos de irradiação (0, 90, 180, 270 graus) e uma dose total planejada de 70 Gy fracionada em 35 sessões, cada uma com 2 Gy. Em qualquer tipo de tratamento que envolva a radiação ionizante é exigido um controle de qualidade para assim, determinar se a dose inicialmente planejada será entregue ou não ao tumor. Idealmente deveria ser implementado um controle de qualidade em três dimensões mas, até o momento não há um dosímetro 3D consolidado na rotina clinica. No entanto, o uso de géis poliméricos associados à técnica de leitura de dose com imagem de ressonância magnética (IRM) possibilita a dosimetria tridimensional. Nesse contexto, é aplicada a dosimetria 3D usando para isso, o gel magic com formaldeído (magic-f). Além da dosimetria 3D, foram realizadas medidas de dose absorvida por meio de dosimetria pontual, para tal fim são utilizados dosímetros termoluminescentes e de alanina. Na avaliação da distribuição de dose feita pelo planejamento e a medida com o gel é usado a análise gama (3%/3mm), neste caso, a distribuição de dose medida concorda com a distribuição de dose planejada TPS. A análise gama apresenta um porcentagem de aprovação do 93%. Os valores de dose absorvida na interface osso-metal determinados pelos dosímetros TL apresentam um aumento de 1,73 Gy na região do osso sacro e outros aumentos entre o 0,16 e 0,33 Gy foram encontrados em regiões como a cabeça do fêmur e quadril. Esses aumentos na dose foram só para duas sessões com doses entregadas ao fantom de 2 Gy. De igual maneira para os dosímetros de alanina se encontro um aumento na dose de 1,22 e 2,42 Gy na região do osso sacro. O planejamento feito nesse caso foi de 6 Gy. Os resultados evidentemente mostram como as inomogeneidades de um material com número atómico alto, gera perturbações sobre as distribuições de dose inicialmente planejadas. / Historically, Radiotherapy is divided into external radiotherapy, brachytherapy and systemic radioisotopotherapy. The difference between the three lies in the position of the radiation source regarding the human body. In external radiotherapy the source is at a certain distances of patient, and in the case of brachytherapy, this source can be inserted into cavities of body or implanted directly in the tissues. In systemic radiotherapy radioisotopes are administered orally or intravenously. Of these three, external radiotherapy is the most used because it allows planning of radiotherapy in three dimensions (3D), starting from a CT scan of the tumor region. Computed tomography planning allows the distribution of radiation in the tissues to be more accurate thus avoiding, that healthy tissues are affected. In our case, conventional external radiotherapy was implemented and executed for a prostate treatment with metal implants, using 4 irradiation fields (0, 90, 180, 270 degrees) and a total planned dose of 70 Gy fractioned in 35 sessions each with 2 Gy. In any type of treatment involving ionizing radiation, quality control (QC) is required to determine if the dose initially planned is delivered or not to the tumor. Ideally, a quality control should be implemented in three dimensions but to date there is no consolidated 3D dosimeter system in the clinic routine. However, the used of polymeric gels associated with magnetic resonance image (IRM) allow three-tridimensional dosimetry. In this context, the 3D dosimetry is applied using the magic gel with formaldehyde (magic-f). In addition to 3D dosimetry, absorbed dose measurements were performed by means of a dose in a point, using thermoluminescent and alanine dosimeters. The comparison of dose distributions calculated by TPS and measured in the gel was made using by gamma analysis (3% / 3mm), in this case, the distribution of dose measurement agrees with the distributions expected by TPS. The analysis shows a percentage of approval of 93%. The absorbed dose values at the bone-metal interface determined by the TL dosimeters, presented a 1.73 Gy increase in the region of the sacral bone, and another increases between 0,16 and 0,33 Gy were found in the regions as the head of the femur and the hip. These dose increases were only for two sessions with doses delivered to the phanton of 2 Gy. Similarly for alanine dosimeters were found increases in the dose of 1.22 and 2.42 Gy in the region of sacral bone. The planning done in this case was 6 Gy. The results evidently show how the inomogeneities of a material with a high atomic number generate disturbances over the initially planned dose distributions.
606

Algoritmo de reconstrução de dose a partir de mapas portais de dose utilizando simulação Monte Carlo / Dose reconstruction algorithm from portal dose maps using Monte Carlo simulation

Eduardo de Matos Rodrigues 15 October 2014 (has links)
Electronic Portal Image Devices (EPID) são dispositivos eletrônicos que foram criados originalmente para aquisição de imagens portais. Atualmente eles também têm sido estudados para reconstrução de dose no plano do eixo central (paralelo ao EPID) na modalidade transit (modalidade que considera um material atenuador entre a fonte e o EPID). Neste trabalho foi determinado um algoritmo de reconstrução de dose para relacionar mapas bidimensionais de dose localizados dentro de geometrias que simularam uma situação clínica em radioterapia de forma simplificada. Para tal foram feitas simulações Monte Carlo utilizando o pacote de simulação PENELOPE de maneira que um cubo composto de água representou o corpo do paciente e um paralelepípedo retângulo composto de água representou o EPID. Definiu-se primeiramente a geometria controle e os parâmetros de irradiação controle e então foram feitas simulações para determinar a equação de reconstrução de dose referencial. Uma vez determinada essa equação, foram feitas novas simulações variando o tamanho de campo, espessura do objeto simulador do corpo, distância entre a fonte e a superfície de entrada do objeto simulador do corpo (DFS) e distância entre a superfície de saída do objeto simulador do corpo e o centro do objeto simulador do EPID (DSDE). Os arquivos de saída dessas simulações alimentaram o programa contendo o algoritmo de reconstrução de dose, feito em MATLAB®. Após a aplicação do programa, comparou-se a matriz que representa o mapa bidimensional localizado dentro do objeto simulador do corpo com a matriz localizada no mesmo local, reconstruída a partir da matriz que representa o objeto simulador do EPID. Os resultados encontrados neste trabalho mostram que a equação de reconstrução de dose e o algoritmo de reconstrução de dose propostos são válidos com desvios padrão menor que 1,6%. / Electronic Portal Image Devices (EPID) were originally created to acquire portal images, but they have also been studied for dose reconstruction in the central axis plane (parallel to the EPID) in transit mode (mode which considers an attenuator material between the source and the EPID). In this work we determined a dose reconstruction algorithm that relate two-dimensional dose maps located within geometries that simulated a clinical situation in simplified form. For this, simulations were performed using the simulation package PENELOPE so that a cube composed of water represented the patients body and a rectangle parallelepiped composed of water represented the EPID. We defined a control geometry and control irradiation parameters first, then simulations were performed to determine the referential dose reconstruction equation. Once determined this equation, new simulations were performed varying the field size, the body phantom thickness, the distance between the source and the body phantom entrance surface (DFS) and the distance between the body phantom exit surface and the EPID phantom center. The output files of these simulations fed the program containing the dose reconstruction algorithm, wrote in MATLAB®. After the program application, we compared the matrix that represents the two-dimensional map located within the body phantom with the matrix located at the same site, reconstructed from the matrix that represents the EPID phantom. The results in this work show that the dose reconstruction equation and the dose reconstruction algorithm proposed are valid with less than 1,6% standard deviation.
607

Resistência de união de cimentos resinosos à dentina previamente submetida a radioterapia / Bonding strength of resin cements to the dentin previously submitted to radiotherapy

Paulo André Yamin 02 February 2017 (has links)
Este estudo avaliou, in vitro, a influência da radioterapia na resistência de união (RU) e na interface adesiva entre diferentes cimentos resinosos e dentina radicular. Sessenta caninos superiores foram distribuídos em 2 grupos (n=30) de acordo com a irradiação: não irradiados e irradiados. Os dentes do grupo irradiado foram submetidos à radioterapia com raios-X de 6 MV em frações de 2 Gy, com 30 ciclos, perfazendo 60 Gy. Os dentes foram seccionados para obtenção de raízes com 16 mm de comprimento, sendo realizado em seguida o preparo biomecânico com instrumento Reciproc R50 e obturação pela técnica de condensação lateral com cimento a base resina epóxica. Cada grupo foi subdividido de acordo com o cimento resinoso utilizado para a cimentação dos pinos de fibra de vidro (n=10): RelyX U200; Panavia F 2.0; RelyX ARC. Os pinos foram submetidos a tratamento de superfície com ácido fluorídrico 10% e cimentados de acordo com as recomendações de cada fabricante. Após a cimentação dos pinos, os dentes foram seccionados transversalmente em slices de 1 mm de espessura, obtendo-se 3 slices de cada terço da raiz. Os slices mais cervicais de cada terço foram utilizados para avaliar a RU, por meio do teste de push-out com velocidade de 0,5 mm/min, e posterior análise do padrão de falha em estereomicroscópio. Os slices mais apicais de cada terço foram selecionados para análise da interface cimento/dentina em MEV com aumentos de 100, 1000, 2000 e 4000X. Os dados de RU e adaptação da interface cimento/dentina foram submetidos à análise estatística pelos testes de ANOVA e Tukey, e Kruskal-Wallis e Duns, respectivamente. Os espécimes irradiados apresentaram menores valores de RU (8,23&plusmn;4,26) comparados aos dentes não irradiados (11,88&plusmn;6,42) (p<0,00001). Quanto aos cimentos resinosos, o RelyX U200 apresentou maiores valores na RU (15,17&plusmn;5,89) comparado aos cimentos RelyX ARC (7,68&plusmn;4,22) (p<0,0001) e Panavia F 2.0 (7,32&plusmn;2,71) (p<0,0001). O terço cervical apresentou maiores valores de RU (13,08&plusmn;6,10) comparado aos terços médio (9,72&plusmn;5,03) e apical (7,38&plusmn;4,53) (p<0,0001). O padrão de falhas mostrou ocorrência de falhas coesivas na dentina para os espécimes irradiados. Na análise da interface cimendo/dentina por MEV, observou-se maior desadaptação nos dentes submetidos à radioterapia. Em relação aos cimentos resinosos, foi observada maior adaptação com RelyX U200 e RelyX ARC comparados à Panavia F 2.0. Na análise qualitativa em MEV observou-se presença de fraturas e microfraturas na dentina radicular e menor presença de fibras colágenas em dentes irradiados. Para o cimento resinoso RelyX U200 e Panavia F 2.0 observou-se interface justaposta do cimento com a dentina radicular em dentes irradiados e não irradiados, sendo que para o cimento resinoso RelyX ARC foi observada formação de camada híbrida e tags de maneira similar para dentes irradiados e não irradiados. Concluiu-se que a radioterapia resultou na redução da resistência de união e na maior desadaptação da interface cimento resinoso/dentina radicular e que o cimento resinoso autoadesivo se apresentou como melhor alternativa para cimentação de pinos de fibra de vidro em dentes irradiados. / This in vitro study, evaluated the influency of radiotherapy on bond strength (BS) and adhesive interface between different resin cements and root dentin. Sixty maxillary canines were selected and distributed into two groups (n = 30) according to the irradiation protocol: non-irradiated and irradiated. The irradiated group were submitted to X-ray radiotherapy of 6 MV in fractions of 2 Gy, with 30 cycles, until complete 60 Gy. The teeth were sectioned to obtain 16 mm of root length, followed by biomechanical preparation with R50 reciproc instrument and obturation using the lateral condensation technique with epoxy resin-based sealer. Then, each group was subdivided according to the resin cement used for the glass fiber post cementation (n = 10): RelyX U200, Panavia F 2.0 and RelyX ARC. The posts were submitted to surface treatment with 10% hydrofluoric acid, and then cemented according to the manufacturer instructions. After the posts cementation, the teeth were sectioned transversely into 1 mm thick slices, and 3 slices were obtained from each root third. The most cervical slice of each third was used to evaluate the BS by the push-out test at 0.5 mm/min of velocity and the failure pattern was analyzed using stereomicroscopy. The most apical slice of each third was selected for SEM analysis, which were prepared and metalized. The dentin/cement interface analysis was performed at the following magnification: 100, 1000, 2000 and 4000X. The BS data and dentin/cement interface adaptation were submitted to statistical analysis by ANOVA, Tukey and Kruskal-Wallis, and Duns tests respectively. The irradiated specimens had lower BS values (8.23 &plusmn; 4.26) compared to non-irradiated group (11.88 &plusmn; 6.42) (p <0.00001). Regarding the resin cements, the RelyX U200 showed the higher values in BS (15.17 &plusmn; 5.89) compared to RelyX ARC (7.68 &plusmn; 4.22) and Panavia F 2.0 (7 , 32 &plusmn; 2.71) (p <0.0001). In addition, the cervical third presented higher BS values (13.08 &plusmn; 6.10) when compared to the middle (9.72 &plusmn; 5.03) and apical (7.38 &plusmn; 4.53) thirds (p <0.0001). The failure pattern showed cohesive failures in root dentin of the irradiated specimens. In the SEM dentin/cement interface analysis, a greater misadaptation was observed for the teeth submitted to radiotherapy. Regarding the resin cements, a better adaptation was observed for the RelyX U200 and RelyX ARC compared to the Panavia F 2.0. In the SEM qualitative analysis of the irradiated teeth, was possible to observe the presence of fractures and microfractures in the root dentin and a small number of collagen fibers. The resin cements RelyX U200 and Panavia F 2.0 showed a juxtaposed interface of the cement with the root dentin in irradiated and non-irradiated teeth, being that for the RelyX ARC cement the presence of hybrid layer and tags was similar for irradiated and non-irradiated groups. It was concluded that the radiotherapy promoted reduction of the bond strength and increase the gaps in the dentin/resin cement interface and the self-adhesive resin cement is the best alternative for glass fiber posts cementation in irradiated teeth.
608

Qualidade de vida e eventos adversos após a radioterapia em mulheres com câncer ginecológico = um estudo de coorte prospectivo / Quality of life and adverse events after radiotherapy in gynecologic cancer survivors : a cohort study

Vaz, Ana Francisca 18 August 2018 (has links)
Orientador: Aarão Mendes Pinto-Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-18T03:36:10Z (GMT). No. of bitstreams: 1 Vaz_AnaFrancisca_D.pdf: 1602661 bytes, checksum: 0dbc9ea54c85593a5a17af092c3b8961 (MD5) Previous issue date: 2011 / Resumo: Objetivos: Investigar a frequência de eventos adversos antes e após a radioterapia, a proporção de mulheres sexualmente ativas, avaliar a qualidade de vida (QV) e identificar seus preditores em uma coorte de mulheres com câncer ginecológico. Métodos: Estudo de coorte prospectivo com 107 mulheres com câncer ginecológico (colo do útero ou endométrio), idade (21 a 75) anos, tratadas com radioterapia, 89 (teleterapia e braquiterapia) 10 (braquiterapia) 8 (teleterapia) no Hospital da Mulher Prof. Dr. José Aristodemo Pinotti CAISM/UNICAMP. A QV foi avaliada através do questionário da Organização Mundial da Saúde - (WHOQOL-breve), antes da radioterapia (T0), 4 meses (T1), 1ano (T2) e 3 anos (T3) após o tratamento. Os eventos adversos após a radioterapia foram graduados de acordo com a escala Common Terminology Criteria Adverse Event (CTCAE) v 3.0. Os escores de QV foram avaliados através do teste de Wilcoxon pareado e os seus preditores identificados por meio de regressão linear. Utilizou-se o teste de McNemar para avaliar as diferenças entre as frequências de sintomas sexuais e da menopausa, e da proporção de mulheres sexualmente ativas após a radioterapia em relação à avaliação inicial. Resultados: A mediana da idade das participantes antes da radioterapia foi 60 anos. O domínio meio ambiente e a saúde geral eram os mais comprometidos antes da radioterapia. Dor (49,5%) e sangramento vaginal (36,9%) foram as queixas mais frequentes. Anemia (p<0,01) e náusea e/ou vômito (p=0,01) interferiram negativamente no domínio físico; dor no domínio físico (p<0,01), QV global (p=0,02) e saúde geral (p=0,01), e história de cirurgia positivamente na saúde geral (p<0,01). Três anos após a radioterapia observou-se uma redução da frequência de secura vaginal (26,7% em T0 vs 8,3% em T3; p<0,005), aumento da proporção de mulheres sexualmente ativas (21,5% em T0 vs 44,2% em T3; p=0,005) em relação à avaliação inicial, e aumento significativo dos escores de QV para o domínio psicológico, saúde geral e QV global. Dor associou-se negativamente com os domínios físico, psicológico e relacionamento social (p<0,05); dispareunia com os domínios físico e relacionamento social (p<0,05); diminuição do interesse sexual com o domínio psicológico (p<0,01) e maior renda positivamente com o domínio psicológico e saúde geral (p<0,05). Conclusão: O domínio meio ambiente e a questão relacionada à saúde eram os mais prejudicados antes da radioterapia. Os sintomas do câncer foram os fatores de maior interferência na QV. Três anos após a radioterapia verificou-se melhora da QV e aumento significativo do número de mulheres sexualmente ativas em relação à avaliação prévia. A presença de dor, dispareunia e diminuição do interesse sexual interferiram negativamente na QV / Abstract: Objectives: To investigate the frequency of adverse events before and after radiotherapy, the proportion of sexually active women, evaluate quality of life (QOL) and identify their predictors in a cohort of women with gynecologic cancer. Methods: A prospective cohort study of 107 women with gynecologic cancer (cervical or endometrial), aged (21 to 75) years, treated with radiotherapy, 89 (teletherapy and brachytherapy) 10 (brachytherapy) 8 (teletherapy) in the Prof. Dr. José Aristodemo Pinotti Women?s Hospital-CAISM/UNICAMP. QOL was assessed by the World Health Organization- (WHOQOL-BREF) questionnaire, before radiotherapy (T0), 4 months (T1),1year (T2) and 3 years (T3) after treatment. The adverse events following radiotherapy were scored according to the Common Terminology Criteria Adverse Event (CTCAE) scale, v 3.0. QOL scores were assessed by the paired Wilcoxon test and their predictors were identified by linear regression analysis. The McNemar test was used to assess the differences between the frequencies of sexual symptoms and menopause, as well as the proportion of sexually active women after radiotherapy compared to baseline evaluation. Results: The median age of the participants before radiotherapy was 60 years. The environmental domain and general health were the most impaired before radiotherapy. Pain (49.5%) and vaginal bleeding (36.9%) were the most frequent complaints encountered. Anemia (p<0.01), nausea and/or vomiting (p=0.01) negatively interfered with the physical domain. Pain negatively interfered with the physical domain (p<0.01), global QOL (p=0.02) and general health (p=0.01). A history of surgery positively interfered with general health (p<0.01). Three years after radiotherapy, there was a decrease in the frequency of vaginal dryness (26.7% in T0 vs 8.3% in T3; p<0.005), an increase in the proportion of sexually active women (21.5% in T0 vs 44.2% in T3; p=0.005) in comparison to baseline assessment, and a significant increase in QOL scores for the psychological domain, general health and global QOL. Pain was negatively associated with the physical, psychological and social relationship domains (p<0.05). Dyspareunia was negatively associated with the physical and social relationship domains (p<0.05). Decreased sexual interest was negatively associated with the psychological domain (p<0.01). A higher income was positively associated with the psychological domain and general health (p<0.05). Conclusion: The environmental domain and the question related to general health were the most compromised before radiotherapy. Cancer symptoms were the factors that most interfered with QOL. Three years after radiotherapy, there was an improvement in QOL and a significant increase in the number of sexually active women compared to prior evaluation. Pain, dyspareunia and decreased sexual interest negatively interfered with QOL / Doutorado / Fisiopatologia Ginecológica / Doutor em Ciências da Saúde
609

Toxicidade pulmonar da radioterapia conformacional torácica em mulheres com câncer de mama. Repercussões funcionais, tomográficas, sistêmicas e seus reflexos na qualidade de vida / Pulmonary toxicity of thoracic conformal radiotherapy in women with breast cancer. Functional, tomographic and systemic impacts and its effects on quality of life.

Adriana Assis Miranda Chaves 24 October 2013 (has links)
O tratamento radioterápico continua aperfeiçoando-se, porém ainda pode estar associado com toxicidade pulmonar. Objetivo: Estudar os efeitos locais e sistêmicos provocados pela radioterapia conformacional torácica adjuvante em mulheres portadoras de câncer de mama, sem fatores de riscos prévios para desenvolvimento de alterações pulmonares. Por meio da tomografia computadorizada de alta resolução; identificar as possíveis alterações radiológicas no parênquima pulmonar. Se presentes, correlacioná-las com parâmetros obtidos da exploração funcional dos pulmões, com os efeitos sistêmicos, pela dosagem de mediadores inflamatórios, IL-1, IL-6 e TNF- , e suas repercussões sobre a qualidade de vida. Material e Métodos: Em 25 pacientes saudáveis foram coletadas amostras de sangue para serem utilizadas apenas como referência de normalidade da IL-1, IL-6 e TNF- . Em decorrência dos rígidos critérios de inclusão e exclusão estabelecidos, das 157 pacientes entrevistadas apenas 24 foram selecionadas para o estudo. A avaliação funcional pulmonar foi abrangente e constou de: medida dos volumes e capacidade dos pulmões, sendo o volume residual obtido pelo método de diluição do hélio em circuito fechado; estudo dos fluxos expiratórios máximos (curva fluxo x volume e curva volume x tempo) e medida da capacidade de difusão pulmonar pela técnica de respiração única do CO. A tomografia computadorizada de alta resolução (16 detectores) foi realizada no pré-planejamento da radioterapia conformacional do tórax, esta com dose total de 45-50 Gy em 25 frações. Para as dosagens de citocinas plasmáticas foram empregadas as técnicas de imunoabsorção enzimáticas (ELISA). Na avaliação da qualidade de vida foi aplicado o questionário Saint George´s Respiratory Questionnary traduzido e adaptado culturalmente ao Brasil. Todos estes procedimentos foram obtidos na fase pré e repedidos 3 meses após a radioterapia. Os resultados das duas fases foram comparados utilizando-se a versão exata do teste Wilcoxon e o teste de Correlação de Spearman, nível de significância p 0,05. Resultados: Entre parâmetros funcionais houve queda significativa apenas na difusão e no fluxo expiratório a 50% da capacidade vital forçada. Mesmo comportamento observou-se para citocina IL-6, já que os mesmos encontravam-se aumentados pré-RT. Não ocorreram mudanças significativas em nenhum dos domínios do questionário de qualidade de vida. As alterações tomográficas ocorreram 60,87% das pacientes na fase pós-radioterapia, em sua maioria de graus leves a moderados e não correlacionaram-se com as alterações observadas em outros parâmetros estudados. Conclusão: O aumento observado na IL-6 durante a fase pré-RT, parece ser um bom índice preditivo de alteração pulmonar. A capacidade de difusão foi a alteração mais evidente e parece ser o índice que melhor reflete as alterações pulmonares que afetam essas pacientes. Diante das discretas alterações tomográficas e funcionais observadas após a RT, é provável que para a redução observada na DLCO concorra uma combinação de fatores ao nível da membrana alvéolo-capilar. No conjunto, as alterações induzidas pela radioterapia conformacional nas pacientes estudadas foram de pequena monta, insuficientes para influenciar aspectos funcionais do pulmão e a qualidade de vida. / Radiotherapy continues to improve itself, but it may still be associated with pulmonary toxicity. Objective: To study the effects caused by local and systemic adjuvant thoracic conformal radiotherapy in women with breast cancer, without risk factors prior to the development of pulmonary alterations. Through high-resolution computed tomography, to identify the possible radiological alterations in the lung parenchyma. If positive identification occurs, correlates it with pulmonary functional parameters, its systemic effects, the dosage of inflammatory mediators IL-1, IL-6 and TNF-, and their impact on quality of life. Material and Methods: Blood samples were collected from 25 healthy patients to be used as a normal reference for IL-1, IL-6 and TNF- mediators. Due to the established strict inclusion and exclusion criteria, only 24 from the initial 157 interviewed patients were selected for this study. The evaluation of pulmonary function was comprehensive and included: Lung volume and capacity measurement through closed loop helium residual volume dilution method;Peak expiratory flow study (flow curve x volume and volume vs. time curve) and CO diffusing capacity measurement through single breath technique. High-resolution computerized tomography (16 detectors) was performed in the pre-planning phase of thoracic conformal radiotherapy where 45-50 Gy total dose was applied in 25 fractions. For cytokines plasma measurement, the enzymatic immunosorbent techniques (ELISA) were used. For quality of life assessment, the Brazil´s validated Saint George\'s Respiratory Questionnary was used. All these procedures were applied in the pre-phase and repeated three months later after radiotherapy sessions. The results of the two phases were compared using the exact version of the Wilcoxon test and Spearman correlation test with p 0.05 significance level. Results: Among the functional parameters, there were a significant decrease in dissemination and expiratory flow at 50% of forced vital capacity. The same behavior was observed for cytokine IL-6, since they were already high at pre-RT. There were no significant changes in any of the aspects of quality of life questionnaire. The tomographic alterations occurred in 60,87% of patients in the post radiotherapy phase, mostly having low to moderate degree and not correlated with the observed changes in other parameters. Conclusion: The IL-6 increase in the pre-RT phase appears to be a reasonable predictive index of pulmonary alterations. The diffusing capacity alterations were the most evident and seem to be the index that best reflects the pulmonary alterations that affect these patients. Given the discrete tomographic and functional abnormalities observed after RT, it is likely that for the observed reduction in DLCO compete a combination of factors occurring at alveolar-capillary membrane level. Overall, the conformal radiotherapy induced changes in the studied patients were not expressive, insufficient to influence the pulmonary functional aspects and the quality of life of the patients.
610

Estudo randomizado testando musicoterapia na redução da fadiga relacionada ao câncer em mulheres com neoplasia maligna de mama ou ginecológica em curso de radioterapia / Randomized trial testing music therapy in reducing fatigue-related to cancer in women with breast or gynecological malignant neoplasms in course of radiotherapy

Alcântara-Silva, Tereza Raquel de Melo 05 April 2012 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2015-11-11T16:34:34Z No. of bitstreams: 2 Tese - Tereza Raquel de Melo Alcântara-Silva.pdf: 3175551 bytes, checksum: 574347502e52a9058a69b0b0001f8cbe (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-11-12T09:23:20Z (GMT) No. of bitstreams: 2 Tese - Tereza Raquel de Melo Alcântara-Silva.pdf: 3175551 bytes, checksum: 574347502e52a9058a69b0b0001f8cbe (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-12T09:23:20Z (GMT). No. of bitstreams: 2 Tese - Tereza Raquel de Melo Alcântara-Silva.pdf: 3175551 bytes, checksum: 574347502e52a9058a69b0b0001f8cbe (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-04-05 / To study the influence of music therapy in reduction of Fatigue related to cancer in patients with breast’s or gynecology’s cancer, during the radiotherapy treatment. METHODS: This is a randomized controled study (Control Group - CG e Musictherapy Group - MTG) wich values fatigue, life’s quality, anxienty, depression by using evaluative instruments Functional Assessment of Cancer Therapy: Fatigue (FACT-F), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI) in three differents moments (during first week of radiotherapy, in the intermediate phase’s week and during the last week of radiotherapy) for patients of bouth groups. Women allocated in MTG, in addition to the scales described above, answered the Music therapy Questionary (MQ), and the Subjective Impression of the Subject’s Questionary in last meeting. Music Therapy sessions were individual and lasted an average of 40 minutes. Music therapeutic techniques used were Musical Audition (MA) and Therapeutic Musical Audition (TMA). RESULTS: 164 women were randomized and 116 women with middle age of 52,9 (CG) and 51,85 years (MTG) were included in the analysis. MTG’s patients had on average 10 music therapy sessions, totalizing 509 assistences during the search. In the analysis between groups, Functional Assesment of Cancer Therapy: Fatigue (FACIT-F) demonstrated significance related to Trial Outcome Index (TOI) (p=0,011), Functional Assesment of Cancer Therapy – Geral (FACT-G) FACT-G (p=0,001) FACIT-F FACT-F(p=0,005) areas to the MGT compared to CG. In comparisson made inside the same group results pointed a significant worsening for women. The GMT showed a significant in TOI, FACT-G and FACIT – F (p<0,001) areas in fatigue scale. Music Therapy Questionary showed that 59,3% of the pacients didn’t know what music therapy was, and 53,7% thought that Music Therapy was a relaxing activity. In the end of the process, based on ISS, 98,1% of the women afirmated that Music Therapy made difference in their lives, 96,2% reported a positive perception of music therapy, 75,5% noticed less fatigue and 84,9% reported less stress. CONCLUSION: Individual Music therapy is effective in treatment of Fatigue Related to Cancer during the radiotherapy, to depression and to improve quality of life. / Estudar a influência da musicoterapia na redução da fadiga relacionada ao câncer em mulheres com câncer de mama ou ginecológico durante o tratamento radioterápico. MÉTODOS: Trata-se de um estudo randomizado controlado (Grupo Controle - GC e Grupo de Musicoterapia - GMT) de avaliação da fadiga e fatores corelacionados (qualidade de vida, ansiedade, depressão) em mulheres submetidas à radioterapia através dos instrumentos avaliativos Functional Assessment of Cancer Therapy: Fatigue (FACT-F), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI) em três momentos distintos (durante a primeira semana de radioterapia, na semana da fase intermediária e durante a última semana de radioterapia) para as participantes dos dois grupos. As sessões de musicoterapia foram individuais, com duração, em média, de 40 minutos. As técnicas musicoterapêuticas utilizadas foram audição musical (AM) e audição musical terapêutica (AMT). RESULTADOS: Foram randomizadas 164 mulheres (82 GC e 82 GMT) e incluídas na análise 116 mulheres com média de idade de 52,9 anos (GC) e 51,85 anos (GMT). As participantes do GMT tiveram em média 10 sessões de musicoterapia, totalizando 509 atendimentos ao longo da pesquisa. Os resultados da FACT-F mostraram maior significância quanto aos domínios Trial Outcome Index (TOI) (p=0,011), Functional Assesment of Cancer Therapy – Geral (FACT-G0 (p=0,005) e Functional Assesment of Cancer Therapy - Fatigue (FACT-F) (p=0,001) para o GMT em relação ao GC. O Questionário Musicoterapêutico mostrou que 59,3% nada sabiam a respeito da Musicoterapia e para 53,7% ela se constituia em uma atividade de relaxamento. Ao final do processo, por meio do questionário Impressão Subjetiva do Sujeito obteve-se que 98,1% afirmaram que a Musicoterapia fez diferença em sua vida; 96,2% relataram percepção positiva da musicoterapia; 75,5% perceberam melhora quanto à fadiga e 84,9% relataram redução do estresse. CONCLUSÃO: A musicoterapia individual é efetiva para a redução da fadiga relacionada ao câncer e dos sintomas depressivos, assim como para a melhora da qualidade de vida de mulheres com câncer de mama ou ginecológico, submetidas à radioterapia.

Page generated in 0.0819 seconds